36-290 (2) 64 SOVEREIGN WAY SM-2020-0020
COMMONWEALTH OF MASSACHUSETTS
CITY OF NORTHAMPTON
GIS#: 10720
Map: 36 3
B'Oek SHEETMETAL PERMIT
Lot. 001 -
Permit: SHEETMETAL
Category: SHEETMETAL
Permit,# SM-2020-0020 PERMISSION IS HEREBY GRANTED TO:
Project# JS-2020-000519
Est.Cost: $6,000.00 Contractor: License: Expires:
Fee Charged:$25.00 PAWEL MISNIAKIEWICZ Sheetmetal-5860 05/28/2020
Balance Due:$.00 Owner: KASAL ARI&BONNIE
#of Fixtures: Applicant: PAWEL MISNIAKIEWICZ
DigSafe# AT: 64 SOVEREIGN WAY
UseGroup
ConstClass
ISSUED ON: 09-Dec-2019 AMENDED ON: EXPIRES ON.-
TO
N:TO PERFORM THE FOLLOWING WORK:
INSTALL DUCT FOR NEW HOUSE
THIS PERMIT MAY BE REVOKED BY THE CITY OF NORTHAMPTON UPON VIOLATION OF
ANY OF ITS RULES AND REGULATIONS.
Signature:
Fee Type: Receipt No: Date Paid: Check No: Amount:
Sheetmetal REC-2020-001973 09-Dec-19 193 $25.00
212 Main Street,Phone:(413)587-1240,Fax:(413)587-1272,F.mail:lhasbrouck@northamptonma.gov
GeoTMSO 2019 Des Lauriers Municipal Solutions,Inc.
Commonwealth of Massachusetts
She t � E D
Date: 9 DEC 9 2019Pe t# 5*1- 20• za
Estimated Job Cost: Permi Fee $ j",oc' L k M2
DEPT OF BUILQI G INSPECTIONS
Plans Submitted: YES NO NORTHAmPbmvR(tM e S NO
Business License Applicant License #
Business Information: Property Owner/Job Location Information: /
Name:
Street: �ji t e ,Z,/ Street:G L( L W
City/Town: �I'n City/Town: //O✓7L
Telephone: �(( �j rj �j� Jr— "(o Telephone:
Photo I.D. required/Copy of Photo I.D. attached: YES NO
staff Initial
J-1 /M-1-unrestricted license
J-2/M-2-restricted to dwellings 3-stories or less and commercial up to 10,000 sq. ft./2-stories or less
Residential: 1-2 familyy Multi-family Condo/Townhouses Other
Commercial: Office Retail Industrial Educational
Institutional
Other
Square Footage: under 10,000 sq. ft. L over 10,000 sq. ft. Number of Stories:
Sheet metal work to be completed: New Work: L/ Renovation:
HVAC t,*'/ Metal Watershed Roofing Kitchen Exhaust System
Metal Chimney/Vents Air Balancing
Provide detailed description of work to be done:
L �zf4ZX 44
Nrw C)L)
INSURANCE COVERAGE:
I have a current liability insurance policy or its equivalent which meets the requirements of M.G.L. Ch.112 Yes�R No❑
If you have checked Yes, indicate the type of coverage by checking the appropriate box below:
A liability insurance policy j& Other type of indemnity ❑ Bond ❑
OWNER'S INSURANCE WAIVER: I am aware that the licensee does not have the insurance coverage required by Chapter 112 of the
Massachusetts General Laws, and that my signature on this permit application waives this requirement.
Check One Only
Owner ❑ Agent ❑
Signature of Owner or Owner's Agent
By checking this box❑, I hereby certify that all of the details and information I have submitted(or entered)regarding this application are true and
accurate to the best of my knowledge and that all sheet metal work and installations performed under the permit issued for this application will be
in compliance with all pertinent provision of the Massachusetts Building Code and Chapter 112 of the General Laws.
Duct inspection required prior to insulation installation: YES NO
Progress Inspections
Date Comments
Final Inspection
Date Comments
Type of License:
By
❑ Master
Title
❑ Master-Restricted
City/Town
❑Joumeyperson
Signature of Licensee
Permit#
❑Journeyperson-Restricted
Fee$
License Number:
Check at www.mass.gov/dpl
�a�9�lq
Inspector Signature of Permit Approval
Load Short Form Job: 55
Wri Pubsoft, Date: Nov 22,2019
Entire House By: R G
P&M MECHANICAL
Project Information
For: "CUSTOM COLONIAL"
64 SOVEREIGN WAY,NORTHAMPTON,MA 01062
Design Information
Htg Clg Infiltration
Outside db(°F) 0 87 Method Simplified
Inside db(°F) 72 72 Construction quality Tight
Design TD(°F) 72 15 Fireplaces 0
Daily range - M
Inside humidity(%) 30 50
Moisture difference(gr/Ib) 31 31
HEATING EQUIPMENT COOLING EQUIPMENT
Make RUUD Make RUUD
Trade RUUD Trade RUUD
Model R96TA0702317MSA Cond RA1336AJl NA
AHRI ref 6482960 Coil RCF3621STAMCA
AHRI ref 7508614
Efficiency 96AFUE Efficiency 11.5 EER, 13 SEER
Heating input 49000 Btuh Sensible cooling 23940 Btuh
Heating output 47040 Btuh Latent000ling 10260 Btuh
Temperature rise 35 °F Total cooling 34200 Btuh
Actual airflow 1223 cfm Actual airflow 1223 cfm
Air flow factor 0.031 cfm/Btuh Air flow factor 0.052 cfm/Btuh
Static pressure 0.50 in H2O Static pressure 0.50 in H2O
Space thermostat Load sensible heat ratio 0.82
ROOM NAME Area Htg load Clg load Htg AVF Clg AVF
(ftz) (Btuh) (Btuh) (cfm) (cfm)
BASEMENT(FUT) 1008 8066 700 246 36
GREAT ROOM 208 4145 3057 127 158
DINING ROOM 195 3373 1947 103 101
DINETTE 140 2042 1509 62 78
FOYER 150 1704 866 52 45
KITCHEN 210 1597 2117 49 110
OFFICE 137 2380 1863 73 97
1/2 BATH 34 1276 529 39 27
MUD/LAUNDRY 106 2801 1373 86 71
BED ROOM 2 176 2576 1711 79 89
BED ROOM 3 182 3021 2206 92 114
BATH 2 51 761 431 23 22
MASTER BED ROOM 283 3944 3408 120 177
MASTER BATH 102 1367 1328 42 69
BoWrtahc values have been manually overridden
Calculations approved byACCA to meet all requirements of Manual J 8th Ed.
wrightsoft- 2019-Nov-22 09:39:24
Right-SuteSUNversal 20l9l9.0.08 RSU13148 Page l
ACCP, ...\Couter\Doarnerts\wrigltsoft HVAC\P&MMEC56.rup Calc=MJ8 FrortDoor faces: N
W.I.C. 51 1008 554 31 29
Entire House 3032 40062 23600 1223 1223
Other equip loads 0 0
Equip.@ 0.92 RSM 21712
Latent cooling 5040
TOTALS 3032 40062 26752 1223 1223
BoWitalic values have been manually overridden
Calculations approved byACCA to meet all requirements of Manual J 8th Ed.
wrightsoft°'
2019-Nov-22 09:39:24
�+ Right-Sute®Uriversal 2019 19.0.08 RSU13148 Page t
ACCK ...\CoLnter\Docvrrerts\WrigWoft HVAC\PBMMEC56.np Calc=MJ8 FrortDoor faces:N