06-044 (11) 241 HAYDENVILLE RD BP-2020-0658 GIS#: COMMONWEALTH OF MASSACHUSETTS Map:Block:06-044 CITY OF NORTHAMPTON Lot: -001 PERSONS CONTRACTING WITH UNREGISTERED CONTRACTORS Permit: Building DO NOT HAVE ACCESS TO THE GUARANTY FUND (MGL c.142A) Category: SOLAR ELECTRIC SYSTEM BUILDING PERMIT Permit# BP-2020-0658 Project# JS-2020-001115 Est.Cost: $55560.00 Fee:$75.00 PERMISSION IS HEREBY GRANTED TO: Const.Class: Contractor: License: Use Group: DEVLIN CONTRACTING & MAINTENANCE 111884 Lot Size(sg. 111 827640.00 Owner: BISHOP PETER Zoning. Ste)/WSP(53)/RR(25)/WP(13)/RI(0)/ Applicant. DEVLIN CONTRACTING & MAINTENANCE AT. 241 HAYDENVILLE RD Applicant Address: Phone: Insurance: 86 FINNELL DRIVE SUITE 21 (781) 812-0420 Workers Compensation WEYMOUTHMA02188 ISSUED ON.1112112019 0:00:00 TO PERFORM THE FOLLOWING WORK-36 PANEL CARPORT MOUNTED SOLAR ARRAY 11.34KW POST THIS CARD SO IT IS VISIBLE FROM THE STREET Inspector of Plumbing Inspector of Wiring D.P.W. Building Inspector Underground: Service: Meter: Footings: Rough: Rough: House# Foundation: Driveway Final: Final: Final: Rough Frame: Gas: Fire Department Fireplace/Chimney: Rough: Oil: Insulation: Final: Smoke: Final: THIS PERMIT MAY BE REVOKED BY THE CITY OF NORTHAMPTON UPON VIOLATION OF ANY OF ITS RULES AND REGULATIONS. Certificate of Occupancy Si:.;nature: FeeType: Date Paid: Amount: Building 11/21/2019 0:00:00 $75.00 212 Main Street,Phone(413)587-1240, Fax:(413)587-1272 Louis Hasbrouck—Building Commissioner Department use only �— City of No ham n St tus o Permit: Building De art ent C rb Cu Driveway Permit 2 4 2019 212 Main Stre t Nw Se er/S ptic Availability Room 00 I W er/W II Availability { Northampton, IV tsSSets�of Structural Plans P, (FPT F C:UIIDINC 1NSPFG phone 413-587-1240 �ax 415 918" ' tin s ite Plans Other Specify APPLICATION TO CONSTRUCT,ALTER, REPAIR, RENOVATE OR DEMOLISH A ONE OR TWO FAMILY DWELLING SECTION 1 -SITE INFORMATION 1.1 Property Address: 29 I yq yd.en 1/i I l e . 12Dad This section to be completed by office 1-eea�5 l�lgi �3�OS 3 Map Lot Unit Zone Overlay District Elm St.District CB District SECTION 2-PROPERTY OWNERSHIP/AUTHORIZED AGENT 2.1 Owner of Record: Pe4­r r- shLA. L-•eeds Mt9 01as3 Name(Print) Current Mailing Address: 913- S-Lyp- IN Telephone Signature 2.2 Authorized Agent: if ri n conne ( I Fi n n-ell Or. QQk 21 Name(P Current Mailing Address: 7�I- Sia- o-2-qD Signature Telephone SECTION 3 -ESTIMATED CONSTRUCTION COSTS Item Estimated Cost(Dollars)to be Official Use Only completed by permit applicant 1. Building Z / 70 GO (a) Building Permit Fee 2. Electrical $25, 0 0 (b) Estimated Total Cost of o Construction from 6 3. Plumbing Building Permit Fee 4. Mechanical (HVAC) / 5. Fire Protection 6. Total = (1 +2 +3 +4 + 5) 5 5 (_Co o Check Number This Section For Official Use Only BuildingPermit Number: Date ��— Issued: Signature: �' I Building Commissioner/Inspector of Buildings Date EMAIL ADDRESS (REQUIRED; EITHER HOMEOWNER OR CONTRACTOR) SECTION 5-DESCRIPTION OF PROPOSED WORK(check all applicable) New House ❑ Addition ❑ Replacement Windows Alteration(s) Roofing ❑ Or Doors D Accessory Bldg. ❑ Demolition ❑ New Signs [0] Decks Siding[C:3] Othefff Solar arm4 ill Brief Description of Proposed.3(/ Panel Carper+moon 4-r Solar array W f Se an),lcc45, JbpX, Work:,0nnh0j-P Mere `[r1Ver rs CAS -}irS ex,S1 ,y7Z9SSs et" JI.3�OSys�cm 'if-rr�n�l,n Alteration of existing bedroom Yes No Adding new bedroom Yes No Attached Narrative Renovating unfinished basement Yes No Plans Attached Roll -Sheet sa. If New house and or addition to existing housing, complete the following a. Use of building : One Family Two Family Other b. Number of rooms in each family unit: Number of Bathrooms c. Is there a garage attached? d. Proposed Square footage of new construction. Dimensions e. Number of stories? f. Method of heating? Fireplaces or Woodstoves Number of each g. Energy Conservation Compliance. Masscheck Energy Compliance form attached? h. Type of construction i. Is construction within 100 ft.of wetlands? Yes No. Is construction within 100 yr. floodplain Yes No j. Depth of basement or cellar floor below finished grade k. Will building conform to the Building and Zoning regulations? Yes No. I. Septic Tank City Sewer Private well City water Supply SECTION 7a-OWNER AUTHORIZATION -TO BE COMPLETED WHEN OWNERS AGENT OR CONTRACTOR APPLIES FOR BUILDING PERMIT I, 7� r- Obi sh Q le• as Owner of the subject propertyZ hereby authorize V l/ n C&I-! A C�� to act on my behalf, in all matters relative to work authorized by this build' g permit application. Signature of Owne Date 1, 'be o -T G1 Co eh'0_ as Owner/Authorized Agent hereby declare that the statements and information on the foregoing application are true and accurate,to the best of my knowledge and belief. Signed under the pains and penalties of perjury. '_&n -T Q'Conn-p u Print Name Signature f Owner/Agent Date SECTION 8-CONSTRUCTION SERVICES 8.1 Licensed Construction Supervisor: Not Applicable ❑Q G Name of License Holder: Re .)ary l n � �,C non e-i I 1,5— , I 1 U O License Number My E; ae 11 DY S4:r- _Z1 Lk)eS jmo Q4) HH 0--Z I g O� 1211202 / Address Expiration Date j &&2=,d -7S(- $1 a-- 67-q ()- Signature Telephone 9.Registered Home Improvement Contractor: Not Applicable ❑ Con18a Co 5 Company Name Registration Number Q0 Q012e 11 Tr (Sk z m z 18-1 OV 03 1 2 021 Address Expiration Date Telephone' I -912— 0zq SECTION 10-WORKERS'COMPENSATION INSURANCE AFFIDAVIT(M.G.L.c. 152,§25C(6)) Workers Compensation Insurance affidavit must be completed and submitted with this application. Failure to provide this affidavit will result in the denial of the issuance of the buil permit. Signed Affidavit Attached Yes...... No...... ❑ City of Northampton � Massachusetts �I• .�. '••c�G l0 DEPARTMENT OF BUILDING INSPECTIONS 212 Main Street • Municipal Building Northampton, MA 010606, AFFIDAVIT Home Improvement Contractor Law Supplement to Permit Application The Office of Consumer Affairs and Business Regulation("OCABR")regulates the registration of contractors and subcontractors performing improvements or renovations on detached one to four family homes.Prior to performing work on such homes,a contractor must be registered as a Home Improvement Contractor("HIC"). M.G.L.Chapter 142A requires that the"reconstruction, alteration, renovation, repair,modernization, conversion, improvement, removal, demolition, or construction of an addition to any pre-existing owner-occupied building containing at least one but not more than four dwelling units....or to structures which are adjacent to such residence or building"be done by registered contractors. Note:If the homeowner has contracted with a corporation or LLC,that entity must be registered Type of Work: Sl So I a r -1-ns--a � 1 Est.Costt::"(55 i S U U• D Address of Work: d 1 I HttV ieny i � I•e 5 11' AJ S ►S 5 Date of Permit Application: 11 - IS - 2o ) 9 I hereby certify that: Registration is not required for the following reason(s): _Work excluded by law(explain): _Job under$1,000.00 Owner obtaining own permit(explain): Building not owner-occupied Other(specify): OWNERS OBTAINING THEIR OWN PERMIT OR ENTERING INTO CONTRACTS WITH UNREGISTERED CONTRACTORS OR SUBCONTRACTORS FOR APPLICABLE HOME IMPROVEMENT WORK ARE NOT ELIGIBLE FOR AND DO NOT HAVE ACCESS TO THE ARBITRATION PROGRAM OR GUARANTY FUND UNDER M.G.L.Chapter 142A.SUCH OWNERS ALSO ASSUME THE RESPONSIBILITES FOR ALL WORK PERFORMED UNDER THE BUILDING PERMIT.SEE NEXT PAGE FOR MORE INFORMATION. Signed under the penalties of perjury: I hereby apply for a building permit as the agent of the owner: 4- I ti- - dal el 2!&y�z to"111- irr. I g d �1�e q Date Contractor Name HIC Registration No. OR: Notwithstanding the above notice,I hereby apply for a building permit as the owner of the above property: Date Owner Name and Signature City of Northampton Massachusetts osPA,zMomr OF BUILDING zmaeECrzmNS e1e m^i" Street °m""i=^p"z Building m"rt^"mpt""' mu vzoan Debris Disposal Affidavit In accordance of the provisions of IVIGL o 40. S54. | acknowledge that an a condition of the building permit all debris resulting from the construction activity governed by this Building Permit shall bedisposed of in a properly licensed solid waste disposal facility, as defined by IVIGL c 111, S 150A. The debris from construction work being performed at: (Please print housE�number and street name) |atobedisposed ufat: sw^ z ) w/oUmOW'J' / 0z (Please print name and location of facility) Orwill bedisposed nfinadumpotaronsite rented orleased from: (Company Name and Address) � Signature ot Permit Applicant or Owner Date B/ If, for any reason, the debris will not be disposed of as indicated, the Applicant or Owner shall notify the Building Department aotothe location where the debris will bedisposed. The Commonwealth of Massachusetts W Department of Industrial Accidents d 1 Congress Street,Suite 100 Boston,MA 02114-2017 •` www mass.gov/dia NVorkers' Compensation Insurance Affidavit:Builders/Contractors/Electricians/Plumbers. TO BE FILED WITH THE PERMITTING AUTHORITY. Applicant Information ) Please Print Legibly Name(Business/Organization/Individual): Lj Address: Sty 1'i n ne( I Dr. S4-e 21 City/State/Zip: OZ k Phone#: 77 7�- Are youempMyer?Check thpriate box: Type of project(required): am a employer with employees(full and/or part-time).* 7. E]New construction ❑I am a sole proprietor or partnership and have no employees working for mein 8. E]Remodeling any capacity. .w. comp.insurance required.] 9. El Demolition 3.F1 I am a homeowner doing all work myself[No workers'comp.insurance required.]t 10[]Building addition 4.❑I am a homeowner and will be hiring contractors to conduct all work on my property. I will ensure that all contractors either have workers'compensation insurance or are sole 11.❑Electrical repairs or additions proprietors with no employees. 12.[:]Plumbing repairs or additions 5.rl I am a general contractor and I have hired the sub-contractors listed on the attached sheet. 13.[—]Roof repairs These sub-contractors have employees and have workers'comp.insurance.: / 6.[:]We are a corporation and its officers have exercised their right of exemption per MGL c. 1'�)Q"rheC t� 6 152,§1(4),and we have no employees.[No workers'comp.insurance required.] Any applicant that checks box#1 must also fill out the section below showing their workers'compensation policy information. t Homeowners who submit this affidavit indicating they are doing all work and then hire outside contractors must submit a new affidavit indicating such. :Contractors that check this box must attached an additional sheet showing the name of the sub-contractors and state whether or not those entities have employees. If the sub-contractors have employees,they must provide their workers'comp.policy number. I am an employer that is providing workers'compensation insurance for my employees. Below is the policy and job site information. Insurance Company Name: (71 uarJ r an C'e 2 Policy#or Self-ins.Lic.#: �2 W C d I�,� Expiration Date: J Z Job Site Address: City/State/Zip: Attach a copy of the workers'compensation policy declaration page(showing the policy number and expiration date). Failure to secure coverage as required under MGL c. 152,§25A is a criminal violation punishable by a fine up to$1,500.00 and/or one-year imprisonment,as well as civil penalties in the form of a STOP WORK ORDER and a fine of up to$250.00 a day against the violator.A copy of this statement may be forwarded to the Office of Investigations of the DIA for insurance coverage verification. I do hereby certify under the pains and penalties of perjury that the information providedlab a is true rnd correct. Signature: c/ ]CPQ I r Date: I l Phone#' ( � b d� `d Z `4 C) Official use only. Do not write in this area,to be completed by city or town official. City or Town: Permit/License# Issuing Authority(circle one): 1.Board of Health 2.Building Department 3.City/Town Clerk 4. Electrical Inspector 5. Plumbing Inspector 6.Other Contact Person: Phone#: Commonwealth of Massachusetts Division of Professional Licensure Board of Building Regulations and Standards Constrijett6r1 tUpervisor CS-111884 i- EXpires: 08/21/2021 BENJAMIN T O'CONNELL, j 74 BAYVIEW AVE QUINCY MA 02168 n a—, Commissioner I✓ Office of Consumer Affairs&Business Regulation HOME IMPROVEMENT CONTRACTOR TYPE:SulDDlement Card Registration valid for Individual use only Registration Expiration before the expiration date. If found return to: 182869 08/03/2021 Office of Consumer Affairs and Business Regulation DEVLIN CONTRACTING AND MAINTENANCE INC. 10 Park Plaza-Suite 6170 Boston,MA 02116 BENJAMIN O CONNELI>' / 86 FINNELL DR 1121 WEYMOUTH,MA 02188 Undersecretary Not vali without signature !+S �-, DEVLCON-01 MGOMEZ ,acoRo CERTIFICATE OF LIABILITY INSURANCE FDATE(MM/DD/YYYY) �� 4122/2019 THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER.THIS CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S),AUTHORIZED REPRESENTATIVE OR PRODUCER,AND THE CERTIFICATE HOLDER. IMPORTANT: If the certificate holder is an ADDITIONAL INSURED,the policy(ies)must have ADDITIONAL INSURED provisions or be endorsed. If SUBROGATION IS WAIVED, subject to the terms and conditions of the policy,certain policies may require an endorsement. A statement on this certificate does not confer rights to the certificate holder in lieu of such endorsement(s). PRODUCER CONTACT R.S.Gilmore Insurance PHONE 27 Elm St (A/C,No,Ext):(508)699-7511 (AA/C, No):(508)695-3597 North Attleboro,MA 02760 ADDRE : INSURERS AFFORDING COVERAGE NAIC# INSURER A:EMC Insurance Companies 25186 INSURED INSURER B:ArnGuard Ins CO Devlin Contracting&Maintenance,Inc. INSURERC: 86 Finnell Drive INSURERD: Weymouth,MA 02188 INSURER E INSURER F: COVERAGES CERTIFICATE NUMBER: REVISION NUMBER: THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED. NOTWITHSTANDING ANY REQUIREMENT, TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN, THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CONDITIONS OF SUCH POLICIES.LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS. INSR TYPE OF INSURANCE ADDL SUBR POLICY NUMBER POLICY EFF POLICY EXP LIMITS LTRINSD WV MMIDD/YYYY MM/DD/YYYY A X COMMERCIAL GENERAL LIABILITY EACH OCCURRENCE $ 1,000,000 CLAIMS-MADE [X]OCCUR 6DO2139 3/20/2019 3/20/2020 DAMAGE TPREMISESO R(EaENTED $ 500,000 currencelMED EXP(Any oneperson) 10,000 PERSONAL&ADV INJURY 1,000'000 GEN'L AGGREGATE LIMIT APPLIES PER: GENERAL AGGREGATE 2,000,000 POLICY jRef LOC PRODUCTS-COMP/OP AGG 2,000,000 OTHER: _ __ $ A AUTOMOBILE uAol ITY COMBINED SINGLE LIMIT $ 1,000,000 ANY AUTO 6Z02139 3/20/2019 3/20/2020 BODILY INJURY Perperson) $ OWNED SCHEDULED AUTOS ONLY X ALIT TNOpSWN p BODILY INJURY Per accident $ X ATOS ONLY X AUTOS O�Y PPerOacECRdent AMAGE $ A X UMBRELLA LIHB X OCCUR EACH OCCURRENCE $ 5,000,000 EXCESS LIAB CLAIMS-MADE 6JO2139 3/20/2019 3/20/2020 AGGREGATE $ 5,000'000 DED I X RETENTION$ 10,000 $ B WORKERS COMPENSATION PERTUTE OTH- AND EMPLOYERS'LIABILITY A ER R2WC014523 4/3/2019 4/3/2020 1,000,000 ANY PROPRIETOR/PARTNER/EXECUTIVE Y❑ E.L.EACH ACCIDENT $ QFFICER/MEMBER EXCLUDED? N/A (Mandatory In NH) E.L.DISEASE-EA EMPLOYEE $ 1,000,000 If Yes,describe under 1,000,000 DESCRIPTION OF OPERATIONS below E.L.DISEASE-POLICY LIMIT $ DESCRIPTION OF OPERATIONS I LOCATIONS/VEHICLES (ACORD 101,Additional Remarks Schedule,may be attached if more space Is required) CERTIFICATE HOLDER CANCELLATION SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE For Informational Purposes THE EXPIRATION DATE THEREOF, NOTICE WILL BE DELIVERED IN P ACCORDANCE WITH THE POLICY PROVISIONS. Only AUTHORIZED REPRESENTATIVE ACORD 25(2016/03) ©1988-2015 ACORD CORPORATION. All rights reserved. The ACORD name and logo are registered marks of ACORD ,DAMES A. CLANCY PROFESSIONAL ENGINEER 601 AS BURY AVENUE NATIONAL PARK, NJ 08063 18561358-1125 LAX: 18561358-1511 Construction Code Office Date: October 17,2019 Re: Structural Certification Sunmodo Ground Mount Structure PV Racking Assembly Subj: Bishop Residence 241 Hardenville Rd Leeds,MA 01053 We have provided a review of the project racking design and calculations in accordance with the IRC- 2015 of the proposed PV ground array solar installation at the above referenced property. We find the foundations, structure, and attachment hardware/methods suitable and in compliance with the required project loading of 117-MPH wind,Exposure`C",and 40-psf Ground snow. Please find attached sealed copies of the project Load and Wind calculations as well as an approved sealed copy of the project estimate sheet. The proposed materials and foundations are in compliance with the required code and loads as noted above. We find the materials stresses to provide a minimum of 150% factor of safety under maximum load combination factoring from all wind directions. The racking design as provided meets and exceeds all required building/structural codes and is suitable for the proposed installation as per the attached drawings S-501.00 dated June 11,2019 and associated load calculations. Should you have any further question or comment please feel free to contact our office. Respectfully, SH OF Aqq J es A.Clancy .JAMES A. N Professional Engineer o CLAhCY MA License#46775 No.46775 9FQtsT�P���e FSS/ONA L�� A B C D E F G H GENERAL NOTES SHEET LIST TABLE 1.1.1 PROJECT NOTES: NEW PV SYSTEM: 11 .340 kWp SHEET NUMBER SHEETTITLE INSIGHT 1.1.2 THIS PHOTOVOLTAIC(PV)SYSTEM SHALL COMPLY WITH THE NATIONAL T-001 COVER PAGE ELECTRIC CODE(NEC)ARTICLE 69Q ALL RELEV ACTC DESA LISTING AND BISHOP RESIDENCE G-001 NOTES INSTALLATION INSTRUCTIONS,AND THE RELEVANT CODES AS SPECIFIED BY THE AUTHORITY HAVING JURISDICTION'S(AHJ)APPLICABLE CODES. A-101 SITE PLAN 1.1.3 THE UTILITY INTERCONNECTION APPLICATION MUST BE APPROVED AND PV A-102 ELECTRICAL PLAN SYSTEM INSPECTED PRIOR TO PARALLEL OPERATION 241 HAYDENVILLE ROAD A-103 SOIARATTACHMENiPLAN CONTRACTOR 1.1.4 ALL PV SYSTEM COMPONENTS;MODULES,UTILITY-INTERACTIVE INVERTERS, AND SOURCE CIRCUIT COMBINER BOXES ARE IDENTIFIED AND LISTED FOR LEEDS MA 01053 E-601 UNE DIAGRAM INSIGHT SOLAR 2 USE IN PHOTOVOLTAIC SYSTEMS AS REQUIRED BY NEC 690.4:PV MODULES: , E 602 DESIGN TABLES UL1103,IEC61730,AND IEC61215,AND NFPA 70 CLASS C FIRE INVERTERS:UL 1741 CERTIFIED,IEEE 1547,929,519CONINNERBOX(ES):UL1703ORUL1741ASSESSOR'S#: NHAMM:0006B:0043L.0001 E-603 PLACARDS PHONE: (413)338 7555 ACCESSORY ADDRESS:89 MARKET STREET 1.1.8 MAX DC VOLTAGE CALCULATED USING MANUFACTURER PROVIDED TEMP S-501 ASSEMBLY DETAILS NORTHAMPTON,MA 01060 COEFFICIENT FOR VOC.IF UNAVAILABLE,MAX DC VOLTAGE CALCULATED R-001 RESOURCE DOCUMENT ACCORDING TO NEC 690.7. R-002 RESOURCE DOCUMENT LIC.NO.: 1.1.9 ALL INVERTERS,PHOTOVOLTAIC MODULES,PHOTOVOLTAIC PANELS,AND HIC.NO.: MA 192102 SOURCE CIRCUIT COMBINERS INTENDED FOR USE IN A PHOTOVOLTAIC R-003 RESOURCE DOCUMENT ELE.NO.: POWER SYSTEM WILL BE IDENTIFIED AND LISTED FOR THE APPLICATION PER UNAUTHORIZED USE OF.Ru 690.4(D).SHALL BE INSTALLED ACCORDING TO ANY INSTRUCTIONS FROM R-004 RESOURCE DOCUMENT PassSETHOVWRITTEN euii F n is IN LISTING OR LABELING[NEC 110.3]. r vwuraN OF u S COPYRIGHT LAWS AND WL BE SUBJECT TO DML 3 1.1.10 ALL SIGNAGE TO BE PLACED IN ACCORDANCE WITH LOCAL BUILDING CODE, DAMAGES AND PROSECu ONS IF EXPOSED TO SUNLIGHT,IT SHALL BE UV RESISTANT.ALL PLAQUES AND NEW PV SYSTEM:11.340 kW SIGNAGE WILL BE INSTALLED AS REQUIRED BY THE NEC AND AHJ. L P 1.2.1 SCOPE OF WORK: - PROJECT INFORMATION BISHOP 1.2.2 PRIME CONTRACTOR IS RESPONSIBLE FOR THE DESIGN AND SPECIFICATIONS OF THE GRID-TIED PHOTOVOLTAIC SYSTEM RETROFIT. T: OWNER RESIDENCE PRIME CONTRACTOR WILL BE RESPONSIBLE FOR COLLECTING EXISTING NAME: PETER BISHOP ONSITE REQUIREMENTS TO DESIGN,SPECIFY,AND INSTALL THE GROUND MOUNT ARRAY PORTION OF THE PHOTOVOLTAIC SYSTEMS DETAILED IN THIS PROJECT MANAGER 241 HAYDENVILLE RD DOCUMENT. NAME: ERIC WILSON LEEDS,MA 01053 q 1.3.1 WORK INCLUDES: AERIAL PHOTO PHONE: (413)8960694 APN:NHAM M:0006B:0043L:000' 1.3.2 GROUND MOUNT RACKING-SUNMODOSUNPORTI SOLAR CARPORT SYSTEM NOT TO SCALE CONTRACTOR 1.3.3 PV MODULE AND INVERTER INSTALLATION -HAN"O-CELLS O.PEAK NAME: INSIGHT SOLAR ENGINEER OF RECORD DUO-GS 3151 ENPHASE 107-60-2-US(240u) PHONE: (413)338 7555 1.34 PV EQUIPMENT GROUNDINGAUTHORITIES HAVING JURISDICTION OFy� _ 1.3.5 PV INSTALLING SYSTEM MONITORING EQUIPMENT _ 1.3.6 PV LOAD CENTERS(IF NEC.) BUILDING: HAMPSHIRE COUNTY cA� JAMES A. yrs -- _1.3.7 PV METERING(IF NEC.) ZONING. HAMPSHIRE COUNTY CLANCY _�- � UTILITYv 5 � 1.3.8 P/DISCONNECTS _ - 1.3.9 PV GROUNDING ELECTRODE 8 BONDING TO(E)GEC -- DESIGN SPECIFICATIONS 1.3.10 PV FINAL COMMISSIONING __ / OCCUPANCY: II 1.3.11(E)ELECTRICAL EQUIPMENT RETROFIT FOR PV _- CONSTRUCTION: SINGLE-FAMILY 5 1.3.12 TRENCHING(IF NECESSARY) ZONING: RESIDENTIAL PAPERS-11-A/r(A-313). ' GROUND SNOW LOAD: 40PSF --_- -- WIND EXPOSURE: B COVER PAGE - WIND SPEED: 117 MPH SCOPE OF WORK DATE: 06.11.2019 SYSTEM SIZE. STC:36z315W=11.34OkW APPLICABLE CODES&STANDARDS PTC:36z2922W=10.48WWDC BUILDING: MASSACHUSETTS RESIDENTIONAL DESIGN BY:A.Y. (36)HANWHA OCELLS Q.PEAK DUO45 315 BUILDING CODE,9TH EDITION,AS CHECKED BY: M.M. (36)ENPHASE 107-00.2-US(240V) AMENDED(780 CMR),IBC 2015 PLAT MAP FIRE: MASSACHUSETTS COMPREHENSIVE N ELECTRICAL: NEC 2017 REVISIONS 6 ATTACHMENT TYPE: SUNMODOSUNPORTIYSOLARCARPORT SYSTEM 02w E FIRE SAFETY CODE(517 CMR 1.00) MSP UPGRADE. NO NOT TO SCALE T-001.00 s A B C D E F G S"B`-' A B C D E F G H 2.1.1 SITE NOTES: NOT EXCEED 120%OF BUSBAR RATING[NEC 705.12(BX2X3)]. PHASE C OR L3-BLUE,YELLOW,ORANGE',OR OTHER CONVENTION 2.12 THE PV MODULES ARE CONSIDERED NON-COMBUSTIBLE AND THIS SYSTEM IS A 2.5.4 THE SUM OF 125 PERCENT OF THE POWER SOURCE(S)OUTPUT CIRCUIT NEUTRAL-WHITE OR GREY UTILITY INTERACTIVE SYSTEM WITH NO STORAGE BATTERIES. CURRENT AND THE RATING OF THE OVERCURRENT DEVICE PROTECTING THE 1 2.1.3 THE SOLAR PV INSTALLATION WILL NOT OBSTRUCT ANY PLUMBING OR MECHANICAL. BUSBAR SHALL NOT EXCEED 120 PERCENT OF THE AMPACITY OF THE IN 4-WIRE DELTA CONNECTED SYSTEMS THE PHASE WITH HIGHER VOLTAGE I N SI G HT-o 2.1.4 PROPER ACCESS AND WORKING CLEARANCE AROUND EXISTING AND PROPOSED BUSBAR,PV DEDICATED BACKFEED BREAKERS MUST BE LOCATED OPPOSITE TO BE MARKED ORANGE[NEC 110.15). ELECTRICAL EQUIPMENT WILL BE PROVIDED AS PER SECTION NEC 110.26. END OF THE BUS FROM THE UTILITY SOURCE OCPD[NEC 705.12(8)(2X3)]. 2.7.9 ELECTRICAL WIRES IN TRENCH SHALL BE ATLEAST 181N. BELOW GRADE 22.1 EQUIPMENT LOCATIONS 2.5.5 AT MULTIPLE ELECTRIC POWER SOURCES OUTPUT COMBINER PANEL,TOTAL (RESIDENTIAL). 2.2.2 ALL EQUIPMENT SHALL MEET MINIMUM SETBACKS AS REQUIRED BY NEC 110.26. RATING OF ALL OVERCURRENT DEVICES SHALL NOT EXCEED AMPACITY OF 22.3 WIRING SYSTEMS INSTALLED IN DIRECT SUNLIGHT MUST BE RATED FOR EXPECTED BUSBAR. HOWEVER, THE COMBINED OVERCURRENT DEVICE MAY BE OPERATING TEMPERATURE AS SPECIFIED BY NEC 690.31(A),(C)AND NEC TABLES EXCLUDED ACCORDING TO NEC 705.12(BX2X3XC). CONTRACTOR 310.15(B)(2)(A)AND 310.15(BX3XC). 2.5.6 FEEDER TAP INTERCONECTION (LOAD SIDE) ACCORDING TO NEC 705.12 22.3 JUNCTION AND PULL BOXES PERMITTED INSTALLED UNDER PV MODULES (BX2XI) INSIGHT SOLAR 2 ACCORDING TO NEC 690.34. 2.5.7 SUPPLY SIDE TAP INTERCONNECTION ACCORDING TO NEC 705.12(A)WITH 22.4 ADDITIONAL AC DISCONNECT($)SHALL BE PROVIDED WHERE THE INVERTER IS NOT SERVICE ENTRANCE CONDUCTORS IN ACCORDANCE WITH NEC 230.42 WITHIN SIGHT OF THE AC SERVICING DISCONNECT. 2.5.8 BACKFEEDING BREAKER FOR ELECTRIC POWER SOURCES OUTPUT IS EXEMPT PHONE: (413)3387555 21.5 ALL EQUIPMENT SHALL BE INSTALLED ACCESSIBLE TO QUALIFIED PERSONNEL FROM ADDITIONAL FASTENING[NEC 705.12(BX5)]. ADDRESS:89 MARKET STREET ACCORDING TO NEC APPLICABLE CODES. 22.6 ALL COMPONENTS ARE LISTED FOR THEIR PURPOSE AND RATED FOR OUTDOOR 2.6.1 DISCONNECTION AND OVER-CURRENT PROTECTION NOTES: NORTHAMPTON,MA 01060 USAGE WHEN APPROPRIATE. 2.6.2 DISCONNECTING SWITCHES SHALL BE WIRED SUCH THAT WHEN THE SWITCH 22.7 SOLAR ARRAY LOCATION SHALL BE ADJUSTED ACCORDINGLY TO MEET LOCAL IS OPENED THE CONDUCTORS REMAINING ENERGIZED ARE CONNECTED TO LIC.NO.: SETBACK REQUIREMENTS. THE TERMINALS MARKED'LINE SIDE-(TYPICALLY THE UPPER TERMINALS). HIC.NO.: MA 192102 2.6.3 DISCONNECTS TO BE ACCESSIBLE TO QUALIFIED UTILITY PERSONNEL,BE ELE.NO.: 2.3.1 STRUCTURAL NOTES: LOCKABLE,AND BE A VISIBLE-BREAK SWITCH. UNAUTHORIZED USE of THIS 2.3.2 RACKING SYSTEM & PV ARRAY WILL BE INSTALLED ACCORDING TO M ING SET MTHOUT WRITTEN 2.6.4 BOTH POSITIVE AND NEGATIVE PV CONDUCTORS ARE UNGROUNDED. PERMISSION FMIJ CONTRACTOR IS IN CODE-COMPLIANT INSTALLATION MANUAL. TOP CLAMPS REQUIRE A WOUTION OF U.S.COFNRIGAT LAWS DESIGNATED SPACE BETWEEN MODULES,AND RAILS MUST ALSO EXTEND A THEREFORE BOTH MUST OPEN WHERE A DISCONNECT IS REQUIRED, IILL KSUaECTTOCNIL 3 MINIMUM DISTANCE BEYOND EITHER EDGE OF THE ARRAYISUBARRAY, ACCORDING TO NEC 690.13. DAMAGESMOPROSECURIONS ACCORDING TO RAIL MANUFACTURER'S INSTRUCTIONS. 2.6.5 ISOLATING DEVICES OR EQUIPMENT DISCONNECTING MEANS SHALL BE NEW PV SYSTEM:11.340 kW 2.3.3 JUNCTION BOX WILL BE INSTALLED PER MANUFACTURERS'SPECIFICATIONS. INSTALLED IN CIRCUITS CONNECTED TO EQUIPMENT AT A LOCATION WITHIN P IT SHALL BE SEALED PER LOCAL REQUIREMENTS. THE EQUIPMENT,OR WITHIN SIGHT AND WITHIN 10 FT OF THE EQUIPMENT.AN BISHOP 2.3.4 ALL PV RELATED ATTACHMENTS TO BE SPACED NO GREATER THAN THE SPAN EQUIPMENT DISCONNECTING MEANS SHALL BE PERMITTED TO BE REMOTE DISTANCE SPECIFIED BY THE RACKING MANUFACTURER. FROM THE EQUIPMENT WHERE THE EQUIPMENT DISCONNECTING MEANS CAN BE REMOTELY OPERATED FROM WITHIN 10 FT OF THE EQUIPMENT, RESIDENCE 2.4.1 GROUNDING NOTES: ACCORDING TO NEC 690.15(A). 2.4.2 GROUNDING SYSTEM COMPONENTS SHALL BE LISTED FOR THEIR PURPOSE,AND 2.6.6 PV SYSTEM CIRCUITS INSTALLED ON OR IN BUILDINGS SHALL INCLUDE A GROUNDING DEVISES EXPOSED TO THE ELEMENTS SHALL BE RATED FOR SUCH RAPID SHUTDOWN FUNCTION TO REDUCE SHOCK HAZARD FOR EMERGENCY 241 HAYDENVILLE RD USE, RESPONDERS IN ACCORDANCE WITH 690.12(A)THROUGH(D) 2.4.3 PV SYSTEMS REQUIRE AN EQUIPMENT GROUNDING CONDUCTOR. ALL METAL 2.6.7 ALL OCPD RATINGS AND TYPES SPECIFIED ACCORDING TO NEC 690.8,690.9, LEEDS,MA 01053 ELECTRICAL EQUIPMENT AND STRUCTURAL COMPONENTS BONDED TO GROUND,IN AND 240. APN:NHAMM:0006B:0043L:000' 4 ACCORDANCE WITH 250.134 OR 250.136(A). ONLY THE DC CONDUCTORS ARE 2.6.8 BOTH POSITIVE AND NEGATIVE PV CONDUCTORS ARE UNGROUNDED, UNGROUNDED. THEREFORE BOTH REQUIRE OVER-CURRENT PROTECTION,ACCORDING TO ENGINEER OF RECORD 2.4.4 PV EQUIPMENT SHALL BE GROUNDED ACCORDING TO NEC 690.43 AND MINIMUM NEC 240.21.(SEE EXCEPTION IN NEC 690.9) NEC TABLE 250.122. 2.6.9 IF REQUIRED BY AHJ,SYSTEM WILL INCLUDE ARC-FAULT CIRCUIT PROTECTION 2.4.5 METAL PARTS OF MODULE FRAMES, MODULE RACKING, AND ENCLOSURE ACCORDING TO NEC 690.11 AND UL1699B. YtH OF k4�, CONSIDERED GROUNDED IN ACCORD WITH 250.134 AND 250.IWA). 2.4.6 EACH MODULE WILL BE GROUNDED USING WEEB GROUNDING CLIPS AS SHOWN IN 2.7.1 WIRING 8 CONDUIT NOTES: MANUFACTURER DOCUMENTATION AND APPROVED BY THE AHJ.IF WEEKS ARE JAMFAS T^ NOT USED,MODULE GROUNDING LUGS MUST BE INSTALLED AT THE SPECIFIED 2.72 ALL CONDUIT AND WIRE WILL BE LISTED AND APPROVED FOR THEIR PURPOSE. N GROUNDING LUG HOLES PER THE MANUFACTURERS'INSTALLATION CONDUIT AND WIRE SPECIFICATIONS ARE BASED ON MINIMUM CODE ,I V REQUIREMENTS. REQUIREMENTS AND ARE NOT MEANT TO LIMIT UP-SIZING. F 2.4.7 THE GROUNDING CONNECTION TO A MODULE SHALL BE ARRANGED SUCH THAT 2.7.3 ALL CONDUCTORS SIZED ACCORDING TO NEC 690.8,NEC 690.7. THE REMOVAL OF A MODULE DOES NOT INTERRUPT A GROUNDING CONDUCTOR TO 2.7.4 EXPOSED PV SOURCE CIRCUITS AND OUTPUT CIRCUITS SHALL USE WIRE 10NAt 5 ANOTHER MODULE. LISTED AND IDENTIFIED AS PHOTOVOLTAIC(PV)WIRE 1690.31(C)].PV OAF�a SOE, .r ANSI S 2.4.8 GROUNDING AND BONDING CONDUCTORS,IF INSULATED,SHALL BE COLORED MODULES WIRE LEADS SHALL BE LISTED FOR USE ON PV ARRAYS, GREEN OR MARKED GREEN IF$4 AWG OR LARGER[NEC 250.1191 ACCORDING TO NEC 690.31(A). NOTES 2.4.9 THE GROUNDING ELECTRODE SYSTEM COMPLIES WITH NEC 690.47 AND NEC 250.50 2.7.5 PV WIRE BLACK WIRE MAY BE FIELD-MARKED WHITE[NEC 200.6(AX6)]. THROUGH 250.106.IF EXISTING SYSTEM IS INACCESSIBLE,OR INADEQUATE,A 2.7.6 MODULE WIRING SHALL BE LOCATED AND SECURED UNDER THE ARRAY. GROUNDING ELECTRODE SYSTEM PROVIDED ACCORDING TO NEC 250,NEC 690.47 2.7.7 ACCORDING TO NEC 200.7, UNGROUNDED SYSTEMS DC CONDUCTORS DATE: 06.11.2019 AND AHJ. COLORED OR MARKED AS FOLLOWS: 2.4.10 DC PV ARRAYS SHALL BE PROVIDED WITH DC GROUND-FAULT PROTECTION MEETING DC POSITIVE-RED, OR OTHER COLOR EXCLUDING WHITE, GREY AND DESIGN BY:A Y. THE REQUIREMENTS OF 690.41(BX1)AND(2)TO REDUCE FIRE HAZARDS. GREEN CHECKEDBY. M.M. 2.5.1 INTERCONNECTION NOTES: DC NEGATIVE-BLACK,OR OTHER COLOR EXCLUDING WHITE,GREY RE,ISIONS 6 2.5.2 LOAD-SIDE INTERCONNECTION SHALL BE IN ACCORDANCE WITH[NEC 705.12 AND GREEN 2.7.8 AC CONDUCTORS COLORED OR MARKED AS FOLLOWS: (B)] 2.5.3 THE SUM OF THE UTILITY OCPD AND INVERTER CONTINUOUS OUTPUT MAY PHASEAORLI-BLACK x-001.00 PHASE B OR L2-RED,OR OTHER CONVENTION If THREE PHASE A B C D E F G H ISHE Z' A B C D E F G H GENERAL NOTES 1 1. FIELD VERIFY ALL MEASUREMENTS 4 INSIGHT1 2. ITEMS BELOW MAY NOT BE ON THIS PAGE - ------- SETBACKLINE J_ / - PROPERTY LINE CONTRACTOR I / 2 MIN SETBACK INSIGHT SOLAR / AREA OF WORK 1 Q.-o„ PHONE: (413)338 7555 / ADDRESS:89 MARKET STREET / NORTHAMPTON,MA 01060 LIC.NO.: HIC.NO.: MA 192102 ELE.NO.: —_—_— ; 3341' / DRAG SET USE OF THIS DRAWINWINSET G WITHOUT WRITTEN PERMISSION FROM CONTRACTOR IS M VIOLATION OF U.S.COPYRIGHT LAWS AND WILL BE SUBJECT TO CML 3 48'-0" / DAMAGES AND PROSECUTIONS. L It I 11 / NEW PV SYSTEM:11.340 kWp 1 MA SMART METER 1 ; AC COMBINER 11 1 / MIN SETBACK FUSED AC DISCONNECT I BOX H 101_0„ BISHOP METER _ - -- // RESIDENCE 241 HAYDENVILLE RD 1 1 / 1 1 ELEEDS,MA 01053 ENTRANCE APN:NHAMM:0006B:0043L:0001 4 0 / ENGINEER OF RECORD m SNOF 1 1 _I __ JAM S A. yam NCA 1 1 Aft 153'-l" �O 153''1" PAPERSIZE„•n,T(ANSIB, s 1 SITE PLAN DATE: 06.11.2019 DESIGN BY:A.Y. CHECKED BY: M.M SITE PLAN N 6 H REVISIONS W E 31128'=1'-0• 0 21-4• 42'A®1 S A-101.00 A B C D E F G H S EET A B C D E F G H GENERALNOTES 1. FIELD VERIFY ALL MEASUREMENTS 4 INSIGHTS 2. ITEMS BELOW MAY NOT BE ON THIS PAGE (N)(1)JUNCTION BOX ARRAY 1-11.340 kW O MODULE STRINGING EXTERIOR PV EQUIPMENT [x36](N)MODULES TILT:10 DEGREES (N)(1)AC COMBINER BOX I AZIMUTH:172 DEGREES O MODULE STRINGING CONTRACTOR I I © MODULE STRINGING INSIGHT SOLAR CONDUIT IN TRENCH 24'DEEP PHONE: (413)3387555 50'LENGTH ADDRESS:89 MARKET STREET / NORTHAMPTON,MA01060 EXTERIOR PV EQUIPMENT LIC.NO.: —————————— (N)(1)MA SMART METER HIC. N 1 FUSED AC DISCONNECT ELE NO.: MA 192102 l)l) ELE.NO.: I O O O O O O I �\ (E)(1)METER UNAUTHORIZEDUSE UETHIS M DRAWING SFE WITHOUT WRITTEN INTERIOR PV EQUIPMENT ME aN WISSIOFFUDs.00v R WT7-AWS (E)(1)MAIN ELECTRICAL PANEL ` AND WIIL BE SUBJECT i0 CML � DAMAGES ANO PROSECUTIONS. @ © © gO © Og i NEW PV SYSTEM:11.340 kWp 0 0 0 0 © 0 ; BISHOP RESIDENCE I © © © © © © I 241 EDS,M 010 RD 53 L----------------------J LEEDS,MA0104 APN:NHAMM:00066:0043L:0001 4 ENGINEER OF RECORD 5 PAPERSRE 1-17'1ANSIB', ELECTRICAL PLAN 39.4° DATE: 06.11.2019 DESIGN BY:A.Y. N MODULE: CHECKED BY: MM 01 ELECTRICAL PLAN H E 66.3° Q-CELLS Q.PEAKDUO-G5315 REVISIONS 1n6•=r o® 315 WATTS A-102.00 A B C D E F G H 1SHEET q A B C D E F G H GENERALNOTES 1. FIELD VERIFY All MEASUREMENTS +INSIGHT29 2. [TENS BELOW MAY NOT BE ON THIS PAGE CONTRACTOR INSIGHT SOLAR 2 PHONE: (413)3387555 ADDRESS:89 MARKET STREET GROUND MOUNT SOLAR MODULES(SEE NORTHAMPTON,MA 01060 SHEET S-501 FOR MOUNTING DETAILS) LIC.NO.: HIC.NO.: MA 192102 v ELE.NO.: V UMUTNG SET USE Of TMS WRn E PERhUSDRAWINGI SET'MTNOUT WRITIFN 2 PERN�SSION FRpA CONTMCTOR IS IN I VIOLATION OF U.S.COPYRIGHT LAWS AIO WIL BE SUBJECT TO CML DNMGES AND PROSECUTIONS. NEW PV SYSTEM:11.340 kWp 19,_10„ BISHOP RESIDENCE 241 HAYDENVILLE RD LEEDS,MA 01053 APN:NHAMM:0006B:0043L:0001 4 1 i ENGINEER OF RECORD ���ti'(H OFcy G �9 G J EN . -A. u GROUND MOUNT CAR PORT STYLE SYSTEM. X900i C'\ �'I FRONT EDGE MUST A MINIMUM I �Q OF S OFF THE GROUND YON AL�G\� 20'-0" 5 PAPER SIZE It'x 1T(ANSI B) 32'-11" SOLAR ATTACHMENT PLAN {.3399.44""� DATE: 06.11.2019 I DESIGN BY:A.Y. N MODULE: CHECKED BY: M.M SOLAR ATTACHMENT PLAN 661.3" O-CELLS R=dISIONS 6 O 1 E Q.PEAK DUO-G5 315 114'=1' 4 1 315 WATTS A-103.00 A B C D E F G H (SHM B) A B C D E F G H CONDUCTOR AND CONDUIT SCHEDULE WIELECTRICAL CALCULATIONS ID TYPICAL CONDUCTOR CONDUIT CURRENT-CARRYING CONDUCTORS OCPD EGC TEMP.CORR.FACTOR CONDUIT FILL FACTOR CONT.CURRENT MAX.CURRENT(125%) BASE AMP. DERATED AMP. TERM.TEMP.RATING AMP.(off TERMINAL N CONDUIT 1 01 1 BAWGTHWN-2,COPPER 1.25'DIA.EMT 6 "A 6AWGTHWN-2,COPPER 0.76(54.7°C) 0.8 12A 15A SSA 33.44A 75°C SOA ;�INSIGHTS 02 1 8 AWG THH -2,COPPER 0.75'DIA.PVC40 2 NIA 6AWGTHWN-2,COPPER 0.96(32.TC) 1.0 36A 45A SSA 52.8A 75°C 50A 03 1 8 AWG THWN-2,COPPER 0.75'DIA.EMT 2 45A 6AWGTHWN-2,COPPER 0.96(32.7°C) 1.0 36A 45A 55A 52.8A 75°C 50A 04 1 6 AWG THWN-2,COPPER 0.75'DIA.EMT 2 NIA 6 AWG THWN-2,COPPER 0.96(32.7°C) 1.0 36A 45A 75A 72A 75°C 65A OMODULE STRINGING CONTRACTOR 2 OB MODULE STRINGING ETHERNET CABLE ENPHASE IQ COMBINER+ INSIGHT SOLAR TO BROADBAND X-I0-AM1-240-2 O MODULE STRINGING ROUTER PHONE: (413)338 7555 125A LOAD CENTER ADDRESS:89 MARKET STREET 120/240V,10,3W NORTHAMPTON,MA 01060 ENPHASE ENVOY MAX.CONTINUOUS CURRENT:65A LIC.NO.: COMMUNICATIONSMAX.OCPD:90A TO UTILITY E E 0.: 192102 GATEWAY (E)120V GRID(OH) J AUTHDRIZEDUSEOFTHIS OUTLET DRAWING SET WITHOUT WRITTEN MIS FROM CONTRACTOR IS IN AND O WDIATION OF U.S.COPYRIGHT TAWS 3 AND WILLL B BE SUBJECT TO CML (36)HANWHA Q-CELLS MAIN SERVICE PANEL DAMAGESANDPROSECUTIONS Q.PEAK DUO-135 315 10A ® L1 2401120 V 10,3W NEW PV SYSTEM:11.340 kWP N MAIN BUSS:200A BISHOP (36)ENPHASE L2 IQ7-60-2-US (E) RESIDENCE UTILITY C 01 15A METER 241 HAYDENVILLE RD 12 RED ' ® LEEDS,MA 01053 IN BRANCH ELACK GROUND ROD APN:NHAM M:0006B:0043L:0001 4 O ------ — ' -------'-- I ENGINEER OF RECORD r--- ---- ` � 15A N G _ (E)GROUNDING 12 "D FUSED (E) ELECTRODE IN BRANCH B `" MA SMART L1 MAIN L_ _ C= METER AC DISCONNECT L2 200 A O60A A 15A 02 LINE LOAD o3 oa N ; TO(E) 5 12 ... R D 1 LOADS WERSIZE 11'a1T(ANSIB) IN BRANCH LINE DIAGRAM _ _ � ----_i f 1 �---_ --- DATE: 06.11.2019 L__J L__J EQUIPMENT LEFT OF EQUIPMENT RIGHT OF DESIGN BY:A.Y. LINE IS(N)NEW LINE IS(E)EXISTING CHECKED BY: M.M. UNLESS OTHERWISE REVISIONS s NOTED. E-601.00 A B C D E F G H SHEET B, A B C D E F G H 1 SYSTEM SUMMARYMODULES INSIGHTS BRANCH R+ 1 BRANCH N2 2 BRANCH 113 REF. OTY. MAKE AND MODEL PMA% PTC ISC IMP VOC VMP TEMP.COEFF.OF VOC FUSE RATING INVERTERS PER BRANCH 12 12 12 PMI.36 36 HANWHA OCELLS QPEAK DUO-G5 315 31SW 291.2W %04A 9.55A 39.87V I 32.98V 1 -0.112VPC(-0.28%PC) 20A MAX AC CURRENT 12A 12A 12A MAX AC OUTPUT POWER 3,000W 3,000W 3,000W INVERTERS ARRAY STC POWER 11,340W AC MAXOUTPUT MAX INPUT MAXflWUT CEC WEIGHTED REF. OTY. MAKE AND MODEL GROUND MAX OCPD RATING RATED POWER ARRAYPTCPOWER 10483W VOLTAGE CURRENT CURRENT VOLTAGE EFFICIENCY MAX AC CURRENT 36A 11-36 36 ENPHASE 10760-2-US 240V FLOATING 20A 290W IAA TSA 48V 9715 CONTRACTOR MAX AC POWER 9,000W 2 DERATED(CEG)AG POWER 9'°00W DISCONNECTS OCPDS INSIGHT SOLAR REF.OTY. MAKE AND MODEL RATED CURRENT MAX RATED VOLTAGE REF. OTY. RATED CURRENT MAX VOLTAGE DESIGN TEMPERATURES SW+ 1 EATON DG222NRB OR EQUIV. 60A 240VAC CB+3 3 15A 240VAc ASNRAE EXTRELE LOW -25.9•C(-11.6•F),SOURCE:BARNES MUNI(42.16°;-72.72") CBI 1 IOA 24(YVAc PHONE: i413j 3387555 ASHRAE 2%HIGH 32.PC(90.97),SOURCE:BARNES MUNI(42.16•;-7272•) F1-2 2 45A 210VAC ADDRESS:89 MARKET STREET NORTHAMPTON,MA 01060 LIC.NO.: HIC.NO.: MA 192102 ELE.NO.: UNRUTHORIZED USE OF THIS DRAWING SET WITHOUT WMTTEN PERMISSION FROM CONTRACTOR IS IN VIOUTION OF U.S.COPYRIGHT UWS ANO U.BE W.ECT TO CML DAMAGES AND PROSECUTIONS. NEW PV SYSTEM:11.340 kWp BISHOP RESIDENCE 241 HAYDENVILLE RD LEEDS,MA 01053 APN:NHAMM:0006B:0043L:0001 ENGINEER OF RECORD PAPERSUS 11',1T(ANSI B) DESIGN TABLES DATE: 06.112019 DESIGN BY:A.Y. CHECKED BY: M.M. REVISIONS E-602.00 E F G H (SHEET T) A B C D E F G H !CAUTION! ja INSIGHT51 POWER TO THIS BUILDING IS ALSO SUPPLIED FROM GROUND MOUNTED SOLAR ARRAYS WITH SAFETY DISCONNECTS AS SHOWN: CONTRACTOR INSIGHT SOLAR 2 • • 6 PHONE: (413)338 7555 RAPIDWITH SHUTDOWN ADDRESS:89 MARKET STREET LABEL 3 eACK FRONT NORTHAMPTON,MA 01060 TURN RAPID SHUTDOWN AT EACH DISCONNECTING MEANS FOR SWICH TO THE'OFF' LIC.NO. MA 192102 POSITION TO SHUTDOWN MC.NO.: PHOTOVOLTAIC EQUIPMENT PV SYSTEM AND REDUCE MAIN DISTRIBUTION ELE.NO.: [NEC 690.13 AND 690.151 SHOCK HAZARD IN ARRAY PV ARRAYUTILITY DISCONNECT UNAUTHORt2ED USE OF THIS DRAWING SET WITHOUT WRITTEN S PERMISSION FROM CONTRACTOR IS N LABEL 1 VIOLATION OF U.S.COPYRIGHT IAWS AND WILL BE SUBJECT TO CML 3 AT RAPID SHUTDOWN SYSTEM - m DAMAGES AND PROSECUTIONS. (NEC 690.56(CKlXA)j. DIRECTORY PERMANENT PLAQUE OR N NEW PV SYSTEM:11.340 kWp DIRECTORY PROVIDING INTERACTIVE PHOTOVOLTAIC SYSTEM THE LOCATION OF THE 0 BISHOP CONNECTED 0 SERVICE ? QTQVOL W SYSMM EM 0 0 PHOTOVOLTAIC SYSTEM DISCONNECT LOCATED DISCONNECTING MEANS D NORTH SIDE OF THE HOUSE AND THE PHOTOVOLTAIC RESIDENCE LABEL 6 LABEL 7 PLAQUE SYSTEM DISCONNECTING MEANS IF NOT IN THE AT POINT OF INTERCONNECTION;LABEL,SUCH AS LABEL 5 OR LABEL 6 MUST IDENTIFY SAME LOCATION ARRAY HOUSE 241 HAYDENVILLE RD PHOTOVOLTAIC SYSTEM [NEC 690.56(8)1 LEEDS,MA 01053 [NEC 705.12(8)(4)] WHERE THE PV SYSTEMS (N)FUSED PHOTOVOLTAIC ARE REMOTELY LOCATED AC DISCONNECT APN:NHAMM:0006B:0043L:0001 q • • • FROM EACH OTHER,A 0 INTERACTIVE PHOTOVOLTAIC SYSTEM 0 0 AC DISCONNECT OEQUIPPED WITH RAPID DIRECTORY IN TO PV ARRAY (E)UTILITY CONNECTED ACCORDANCE WITH 705.10 ENGINEER OF RECORD OPERATING CURRENT. 36.0 A Ac SHUTDOWN SHALL BE PROVIDED AT OPERATING VOLTAGE: 240VAC EACH PV SYSTEM (N)AC COMBINER LABEL 6 LABELS LABEL 10 DISCONNECTING MEANS. PANEL (E)METER AT UTILITY METER AT POINT OF INTERCONNECTION,MARKED AT RAPID SHUTDOWN SWITCH PV SYSTEM EQUIPMENT [NEC 690.56(8)) AT DISCONNECTING MEANS [NEC 690.56(C)I. AND DISCONNECTING [NEC 690.541 LETTERS AT LEAST 316 INCH;WHITE ON RED MEANS SHALL NOT BE BACKGROUND;REFLECTIVE INSTALLED IN BATHROOMS FC 605.11.1.1 [NEC 69OA(D),(E)] PHOTOVOLTAIC O PHOTOVOLTAIC O PAPER SIZE 11', ANSI B'. 5 POItlER SOURCEAC DISCONNECT TO AC DISCONNECT GRADE PLACARDS LABEL 11 LABEL 12 LABEL 13 AT EXPOSED RACEWAYS,CABLE TRAYS,AND OTHER WIRING AT EACH AC DISCONNECTING MEANS AT POINT OF INTERCONNECTION TO AC COMBINER PANELTO(E)MSP(INSIDE) METHODS;SPACED AT MAXIMUM 10 FT SECTION OR WHERE [NEC 690.13(8)1 OVERCURRENT DEVICE DATE' 06'1121119 SEPARATED BY ENCLOSURES,WALLS,PARTITIONS,CEILINGS, LABELING NOTES [NEC 705.12(BX2K3XB)I N MA SMART METER DESIGN BY:A.Y. OR FLOORS. 1.1 LABELING REQUIREMENTS BASED ON THE 2017 NATIONAL ELECTRICAL CODE,INTERNATIONAL FIRE CODE 605.11,OSHA INEC 690.31(G)1 STANDARD 1910.145,ANSI 2535 CHECKED BY; M.M. LETTERS AT LEAST 31B INCH;WHITE ON RED BACKGROUND; 12 MATERIAL BASED ON THE REQUIREMENTS OF THE AUTHORITY HAVING JURISDICTION. REFLECTIVE PERMANENTLY MENT ELEVATION REVISIONS 1.3 LABELS TO BE OF SUFFICIENT DURABILITY TO WRNSTAND THE ENVIRONMENT INVOLVED. 6 [IFC 60511 1 11 1.4 1.5 ALERT NG WORDS TO BE COLOR CODED.DANGERELS TO BE A MINIMUM LETTER HEIGHT OF NWILL HAVE RED BACKGROUND;WARNING'WILL HAVE ORANGE Z_�qff BACKGROUND;'CAUTION'WLLL HAVE YELLOW BACKGROUND.[ANSI Z535I E-603.00 A g C D E F G H (SHEET 8) A B -- 1 --- _ _a_ F G H INSIGHTS rrrrfrr. iirsrs.wrsrs�rr� '�.+'i�a�.r�,.�rrr.��. 86 KB0661-0QE BKACE KIT 4 83 IK7101794)M K11 BPIXE K77 4 ww.f.e.r.r�r "'a � irr��wr �i�wrars w m BPI o IOT 4 iIw :ffrrrrrfrr.+fwr�r.� assrrrrrwrf.rniA�.Rfr. 22 0B 100080 L40U1i KR 4 ....rtar+sar ffi 007 NNWTVWH 4 001 � a CONTRACTOR 193 IJCE KR 4 lY 1ffi BO 00l1M 81 78 000 ML CLA PKR " INSIGHT SOLAR 2 aw 'r'r'�arr•�• �i�aw.�.: r^+'rr17 M M OLABPK/T 60 rr.r.rr.ur ww..r �rr�'•o�aaw.rw� nw� 70 KH WGIKR1 10 01 IAIBCHRAL 12N'T PHONE: (413)3387555 rte. rrAr.rarr�rr.rrrrs.r r 14 K10000-008 P=lQT 46 ADDRESS:69 MARKET STREET 18 01 ULLWPEPAD 4 NORTHAMPTON,MA 01060 rrr��v r 14 816009-001 IFLANN MIT 11441D 24 rfaA�I wrr��� rs>_ 11 BImm-006 CAPSCREWIA49DX114 ffi 'r�....... i ro.�l..�r.,�a�rirDETAIL D 10 PLATE 4 LIC.NO.: i9 A20006180 ENDCAP Y 4 HIC,NO.: MA 192102 9 ASIM-001 BOX BEAM 9 ELE.NO.: r.r •�ar.r DNAED USE Of TRI$ ifr 7 1M A1101767 A110176 OONB1 4 DRAWING WING SET WITHOUT WRITTEN irrrt 9 166 BOX111EAM.L.4111111 B PERMISSION FROM CONTRACTOR IS IN ae�rffrrsr.�r fRr1 ' VIOLATION OF U.S.COPYRIGHT UW$ 6 76219 L.910 9 3 AND WILL BE SPRIEST CML 4 76188(1 BEAY,4166 = DAMAGES AND PROSECUTIONS. rfwwfrarefraA� fvf>�fr. 6 AM754080 BEAKWOB 9 NEW PV SYSTEM:11.340 kWp iw.v,srArr�.r.ras,�� Y46183 RAL,163860(F$JO HEAVY), M �----� ,94 BISHOP OCTAL A OETAL B ' OUAL 0 1 PANSAGIV1X1MOXII&m ffi RESIDENCE 241 HAYDENVILLE RD LEEDS,MA 01053 APN:NHAMM:0006B:0043L:0001 4 q ANCHOR BOLT 9RAoe ENGINEE RECORD >f100 IH OF M4�1c o9rAL EITT] I I I—Ll �I 01106 O� JAMES A y�A CY .46775 ' yl Fh�/CMIAL ENGR� 00 6 PAPER SIZE 11-a 17'(ANSI BI DUAL E 1MO0 ASSEMBLY DETAILS GRADE " DATE: 06.11.2019 YAX Br1ADE ue DESIGN BY:A.Y. CHECKED BY: M.M. 1 REVISIONS 6 S-501,00 AB ° L E F G H A B at C D ax E rar F ax G rat H R, MECHANICAL SPECIFICATION (OINSIGHT Fd,u1 66.3 in x.1 in x 1.26 in 2..)ding 1-1)1010 x 1000 116851010 x 3210101 tM 13'. 6erma 5119.JNg1 rRd e.•-nnw F,RCww 0.13in(3.2mmltlh Pra�slrgs NBlaa rvitN anti-rellectan lecNnology .M,otax Cdnnow.lm - CONTRACTOR F- 31.1,aroE-aluminum Call 6x20mmdcryMelNnep.ANTUMsdWNalfulls L, INSIGHT SOLAR 2 IseVaam 2.]63.351,x1.9]-2.761,x0.51-0.83(n 170851010 x M-70(nn x 13ec21 mm1.dA-ad,IP67 CaYa 41010=Sold cade;l*J z43.3in(110010101,(-1 x43.31,II IOOmmI ��,,,�� •.� ry..,a- -"' C<.Mrr MCA.IM PHONE: (413)3387555 ELECTRICAL CHARACTERISTICS ADDRESS:89 MARKET STREET ' ROWER c1A56 315 3. a2s Sao NORTHAMPTON,MA 01060 MINIMUM PERFORMANCE AT STANDARD TE51 CONDITIONS.STC(POWER T-AN .5 W 14W) PPnrc'.." P.. IW] 315 320 325 330 UC.NO. ! x 1 11 SNml D.A.A_Aad' 4 u1 too,, 10.09 10.14 1o.2o HIC.NO.: MA 192102 E "A"CRa`""aa v. In 39.8) .0.13 40.40 40.66 ELE.NO.: Cued At MPP 1•. UI 9.55 9.60 9.66 9.71 UNAUTIARIZEDUSEOFTHIS v......MPP v.. 1v1 32.98 3332 33.55 33.98 DRAWING SET VwT1101n WRITTEN The new Q.PEAK DUO-G5 solar module from Q CELLS impresses thanks 1AN_ 1 n 1%) x18.7 19.0 193 x19.6 PERMISSION FR ON CDNTRACTOR IS IN to innovativeO.ANTUMDUO Technology,which enables articular) high MINIMUM PERFORMANCE AT VWIATIONOFU.S.CDPYRIGHTLAWS particularly g ANDMLL BESUBJECTTOCML 3 performance on a small surface.Q.ANTUM's world-record-holding cell PP.rAtMPP P.. Ian 2353 239.0 2423 246.5 DALIAGESANDPROSECU110N5. concept has now been combined with state-of-the-art circuitry half cells a SNwlcacaxD_ 1.. IAI $09 81 3 8.17 8.22 and a six-busbar design,thus achieving outstanding performance under _ aPe DNNNNWMte V. [vI 3752 37.77 3,02 W.27 NEW PV SYSTEM:11.340 kWp �® CMdd At MPP 1.. GI 7.52 7.56 7.60 7.64 real conditions-both with low-intensity solar radiation as well as on ifs v„M,edM.P v. Iw 31.30 31,62 3196 3225 BISHOP hot,clear summer days. �r M.I. IIM m, P...,a� ...S.N.Tf IDnnWm.,s,I A.ISA.ro.n Mlfd�n-, adnW,�NM,T.PI m Mls O CELLS P-DAMANCE wARA_ PERAIRMANCE AT LOW wRA CE II ANTUM TECHNOLOGY:LOW LEVELIZED COST OF ELECTRICITY - reN - a - MNnl sax dwIIIRESIDENCE Higher yield per surface area,lower BOS costs,higher power • _ u N93m• to :. classes,and an efficiency rate of Up to 19.9%. `'-- E3• MlnaM asx -N1xMa.�m - -+�. , >' Ml data wnnm measW,aNM bbanc¢ E , ' INNOVATIVE ALL-WEATHER TEcxnotocr241 HAYDENVILLE RD Q Wm WrIneOCELLSSWesaryniralim Wajaul • a • - Optimal yields,whatever the weather with excellent low-light �• udca,min � � LEEDS,MA 01053 and temperature behavior. APN:NHAM M:0006B:0043L:0001 4 a •,.-�:_.:,_�.. _ • .w. Lroxal module,eHamax<Mdd brIlMNOaIIYY(aM � ENDURING HIGH PERFORMANCE 111 Long-term yield security with Anti LID and Anti PID TechllWngyl, max"ERawar coE'Dolass ENGINEER OF RECORD Hot-Spot Protect and Traceable Quality Tra.OdM. mwMry Mis TaMPadNxa Critl.dd4 lx/xl .can Temperawre CRexici<d R1v A I%/KI -0.28 R EXTREME WEATHER RATING Tda�-caaaNd ld P., r t%/x1 -0.37 N.-Mod„ Pea DAR,,Tem ,im NMor [1 10 x5.4 t43 13 T) 20i8 C High-tech aluminum alloy tram¢,certified fp high SnowPROPERTIES R.SYSTEM DESIGN (5400 Pal and wind loads(4000 Pal regarding IEC. I11NNatias7lMd Wo-v„ Ivl 1000 UECI nOoo wu s„dy CIA. ll - IYW�f�YFlr eaaNl IA OCI 20 Fire Raxnt COEM 7 TYPE I IUL) O A RELIABLE INVESTMENT tta r.I'ur vw uesmn 75 13600RAI/s5 c2667 P„ PsARi�me module temPenw. -ao•F Mp 185'F Inclusive 12-year product warranty and 25-year (adatr rP. 1\ ii .oro ,NRva dNrE 1 1 1-a•c vR to.as•c) "'*'�"•,b t `�� Ya iRM1�1,/EYIPUII• IWaM'1 113(5a00Pal/84(4000 Pal IaNaNRn manual linear performance guaranteed. �;^�• STATE OF THE ART MODULE TECHNOLOGY 10,a00025m t I g UL 1A3,vDF M�a:ny Tesleu.CE cwnN ; NuaMer aT Modules Rer P„let 32 1 QANTUM DUO combines cutting edge cell separation 1EC61215.2o16.1Ec 61730.z0T-11--A A eamee,„Pane,rvr s3•nMMr 30 s PAFERSIZEn nnyaxsl a; and innovative wiring with O.ANTUM Technology. APT Test co"""A'acc"'N"'to x.ar d Pane.pa,4o xitn cwe cawin, n s IIECITS 62806-1:2015, l�R��` c 5eedata 8(-150OV.1­1 ol mal«6runner DVE C E eMw Pan„Dim A-(Ixwxx) 1176omm.�m�na5m.3m1>j �m RESOURCE DOCUMENT THE IDEAL SOLUTION FOR: 'nloini1ion a.d P„Iet IN."lu I415Ms16421ry1 i Nolo Im1M W,m muuct.as mvN b 1MMPa.SR the NxwNr a:„noerNiat m,ava d ePaNxl Pu,IKnma s,.x.ael»naxm M Ian,,.mMmMaa as a,"aMd�mMll„o,-6 w DATE: 06.11.2019 Ma1wM a�U 3mARA-A,CmMl-O.ne.5uid12W.Min.G92619.-1.119A9)<e59%IfMArtinnviry0us.y-nscomIWE.wrvgcens.w DESIGN BY:A.Y. Engineered in Germany Q CE«S CHECKED BY: M.M. 6 REVISIONS R-001.00 A B C 0 Air E F G H SHEET 10 A as B C as D as E as F as G as H Data Sheet Enphase IQ 7 and IQ 7+Microinverters 4 INSIGHT Enphase Microinverters Region:AMERICAS INPUT DATA(DC) 107-60-2-US J 1Q7PLUS-72-2-US _ Commonly used module pairings' .235 W-350 W+ 235 W-440 W+ Module compatibility 60-cell PV modul rs only 60-ce11 and 72-cell PV modules Maximum Input DC voltage 48V 60 V Peak power tracking voltage 27 V-37 V 27 V-45 V Operating range 16V-48V 16V-60V CONTRACTOR Min/Max start voltage 22 V/48 V 22 V/60 V Max DC short circuit current(module lsc) 15A 15A 2 Enphase The high-powered smart grid-ready DCportbackfeedcurentOvervaltage class DC D D + INSIGHT SOLAR Enphase IQ 7 Micro'"and Enphase IQ 7+Micro- DCarrayc configuration tion DA o A PV array corNiguratian 1 x 1 ungrountle array;No additional DC side protection required; IQ 7 and IQ 7+ dramatically simplify the installation process while AC side protectic requires max 20A per branch circuit PHONE: @13)3387555 OUTPUT DATA(AC) 10 7 Microlnver er 10 7 Microinverter achieving the highest system efficiency. ADDRESS:89 MARKET STREET Microinverters Peak output power 250 VA 295 VA NORTHAMPTON,MA 01060 Part of the Enphase IQ System,the IQ 7 and Maximum continuous output power 240 VA 290 VA Q 7+Microinverters integrate with the Enphase Nominal(L-L)voltage/range' 240 V/ 208V/ 240V/ 208V/ 9 P 211-264 V 183.229 V 211-264 V 183.229 V LIC NO.: IQ Envoy'",Enphase IQ Battery',and the Enphase Maximum continuous output current 1.0 A(240 V) 1.15 A(208 V) 1.21 A(240 V) 1.39 A(208 V) P HIC.NO.: MA 192102 Enlighten-monitoring and analysis software. Nominal frequency 60 Hz 60 Hz g ELENO.: Extended frequency range 47-68 H2 47.68 H2 INAUTI10112ED lISE OF THIS IQ Series Microinverters extend the reliability AC short circuit fault current over 3 cycles 5.8 Arms 5.8 Arms DRAWING SE"T"OUT WRIT1EN Maximum units per 20 A(L-L)branch circuit 16(240 VAC) 13(208 VAC) 13(240 VAC) 11(208 VAC) PERMISSION FROM CONTRACTOR IS N standards set forth by previous generations and OvervoltageclassACPon IN III VIOLATION OFUSCoMRIGHTUWS AC port backfeed current OA OA AND Wal SE SUBJECT TO CNIL 3 undergo over a million hours of power on testing, waucESANDPROSECUTI MS. enabling Enphase to provide an industry-leading Power factor setting 1.0 1.0 Power factor(adjustable) 0.85leading...0.15 agging 0.85 leading...0.85 legging NEW PV SYSTEM:11.340 kWp warranty Of up t0 25 years. EFFICIENCY @240 V @208 V @240 V @208 V Peak effickncY 976% 97.6% 97.5% 97.3%-- ---i--�- BISHOP 9101 1011 .EC hted efficiency 97.0% 97.0% 97.0% 97A% B S n P MECHANICAL DATA Ambient temperature range -40eD to+65-C - RESIDENCE Relative humidity range 4%to 100%(condensing) Easy to Install Connector type (107-60-2-US8107PLUS-72-2-US)MC4(or AmphenolH4UT%with additional Q-DCC-5 adapter) p Dimensi¢ns(WxHXD) 212 mmmmm x175mx30.2 (withoutbracket) 241 HAYDENVILLE RD • Lightweight and sim le weight 1.08 kg(2.38 But) •Faster installation with improved,lighter two-wire cabling Cooling Natural convection-No fans LEEDS,MA 01053 •Built-in rapid shutdown compliant(NEC 2014 8 2017) Approved for wet locations Yes 4 Pollution degree P03 APN:NHAM M:0006B:0043L:0001 Productive and Reliable Enclosure Class II double-insulated,corrosion resistant polymeric enclosure Environmental category/UV exposure rating NEMA Type 6/outdoor ENGINEER OF RECORD •Optimized for high powered 60-cell and 72-cell-modules FEATURES •More than a million hours of testing Communication - - Power Line Communication(PLC) •Class II double-insulated enclosure Monitoring Enlighten Manager and MyEnlighten monitoring options. Both options require installation of an Enphase 10 Envoy. •UL listed Disconnecting means The AC and DC connectors have been evaluated and approved by UL for use as the load-break disconnect required by NEC 690, Smart Grid Read Compliance CA Rule 21(UL 1741-SA) Y UL 62109.1,UL1741/IEEE1547,FCC Part 15 Class B,ICES-0003 Class B. • Complies with advanced rid support,voha a and CAN/CSA-c22.2 N0.107.1-Oi P 9 PP 9 This product is UL Listed as PV 2.1-2 Shut Down Equipment and down of with NEC-2014 and frequency ride through requirements NEC-2017 section 690.12 and C22.1-2015 Rule 64-218 Rabid Shutdown of PV Systems,for AC •Remotely updates to respond to changing ___________. _ _ and DC conductors,when installed according manufacturer's instructions. grid requirements 6 Configurable for varying grid profiles PAPER SIZE ro.nyANs BI •Meets CA Rule 21(UL1741•SA) RESOURCE DOCUMENT •The 107+Micro is required to suppon 72 cell modules. t Noen(o,,,dDC/ACciho.See the compatibility calculator at hltDa:/laophA6<.F¢tIILP.dui/9¢pD¢tl/al¢d11lGcfllOpallDilltY V 2. m N¢n,involtage range nun be extended bey¢nd n,min,l if,egvhed by the aunty. DATE: 06.11.2019 3.Limps may vary.Refer to local requirements to define the number of microinverwrs per branch In your area. E N P H AS E To learn more about Enphase offerings,visit enphase.com EN PHASE DESIGN BY:A.Y. To learn more about Enphase offerings,visit erlphase.com V _2'19 Enphase Energy As ryrnsreservee.All bademixks or brands vsr ll�pmpeny f Enphase Energy.Inc V CHECKED BY: M.M. 20193.26 6 REVISIONS R-002,00 A as8 C D E F G H s+EE1•I A as B ax C as D as E as F as G as H ;.,;:; t.,,1 Enphase IQ Combiner+ 4 INSIGHTi? Enphase Networking MODEL NUMBER IQ Combiners X-1Q-AMI-240-2 IQ Combiner+with Enphase IQ Envoy"for integrated revenue grade PV production metering (ANSI 012.20+/-0.5%)and opuonar consumption monitoring(+/.2.5%). CONTRACTOR _____ _ ._____ .__._______—__. ACCESSORIES(order separately) Enphase Mobile Connect" v - INSIGHT SOLAR 2 Enphase The Enphase IQ Combiner+'"with Enphase CELLMODEM-03(41/12-year data plan) Plug and play Industrial grade cellular modem with data plan for systems up to 60 CELLMODEM-01(3G/5-year data plan) microinverters.(Available in the US,Canada,Mexico,Puerto Rico,and the US Virgin Islands, IQEnvoy'"consolidates interconnection CELLMODEM-M1(4GLTE CAT-M1/5-year data plan) where there is adequate cellular service in the installation area.) IQ Combiner+ ConsumptiunMonitoring CT PHONE: (413(3387555 equipment into a single enclosure and CT-200-SPLIT Split core current transformers enable whole home consumption metering,(+/-25%) ADDRESS:89 MARKET STREET X-IQ-AM1-240-2 streamlines PV and storage installations b Circuit Breakers NORTHAMPTON,MA 01060 9 Y BRK-15A-2-240 Breaker,2 pole,15A,Eaton BR215 lOVIOIn aconsistent,pre-wired solution for BRK-20A-2-240 Breaker,2 pole,20A,Eaton BR220 providing p re-wELECTRICAL SPECIFICATIONS LIC.NO.: residential applications.It offers up to fourRating Continuous duty HIC.NO.: MA 192102 ELE.NO.: 2-pole input circuits and Eaton ESR series System voltage 240 VAC,60 HZ UNAUTNORIZEDUSE 01T811 Eaton BR series busbar rating 125 A DRAWING SET WITHOUT WRITTEN busbar assembly. PERMISSION FROM CONTRACTOR IS IN Max.continuous current rating(output to grid) 65A VIOLATION OF U.S.COPyRIGin U.S Max.fuse/circult rating(output) 90A AND'MIL BE SUBJECT TO CML 3 DAMAGES AND PROSECUTIONS. Branch circuits(solar end/or storage) Up to four 2-pole Eaton BR series Distributed Generation(DG)breakers oMy(not included) Max.continuous current rating(input from PV) 64A NEW PV SYSTEM:11.340 kWp Max.total branch circuit breaker rating(Input) 80 A(any combination) BISHOP Production Metering CT 200 A solid core pre-Installed and wired to IQ Envoy Smart MECHANICAL DATA Dimension' (WxHxD) 49.3x46.5x16.0CM(19.4'x18.3'x6.3) RESIDENCE 'Includes oEnvoy fm communication J and controlf Weigh 7.5 kg(16.5 lbs) Flexible nworking supports w-Fi. Ambient temperature range -40-Cto+46-C(-40-to 115-F) et Ethernet,or cellular Coding Natural convection,plus heat shield 241 HAYDENVILLE RD - Provides production metering and optional Enclosure environmental rating Outdcor,NRTL-anifetl,NEMA type SIR,polycarbonate construction LEEDS,MA 01053 consumption monitoring Wire sizes 20 A to 50 A breaker inputs:14 to 4 AWG copper conductors 4 APN:NHAM M:0006B:0043L:000' 4 Supports installation the 60A6ug co branch input:30 to 2/0 AWG copper Enphase Q Aggregator Main lug combined output:10 tg 2/0 AWG copper conductorcTriiI, AlwayNeutras follow and code 4 to Oments orcond-nducconductor ENGINEER OF RECORD !� "' ns Always follow local code requirements for corMuctw siting. Simple Altitude To 2000 meters(6,560 feet) •Eaton BR series panelboard Interior INTERNET CONNECTION OPTIONS -1' (Y Up to four 2-pole branch circuits for 240 VAC Integrated WI-FI 802..Cal n 3 1 I•. Ethernet 802 3. e15E(or Cal 6)UTP Ethernet cable-not included plug-in breakers(not included) •80 A total PV or storage branch circuits Cellular Optional,CELLMODEM-01(3G)or CELLMODEM-03(4G)(not included) COMPLIANCE Reliable Compliance.Combiner UL 1741 CAN/CSA C22.2 No.107.1 •Durable NRTL-carts(ed NEMA type 47 CFR,Part 15,Class B.ICES 003 Production metering:ANSI C12.20 accuracy class 0.5(PV production) 5 311 enclosure PAPER SIZE 11',17'iANS BI •Five-year warranty Compliance,IQ Envoy CAN/CSA C22.2 No.61010-1 • RESOURCE DOCUMENT UL listed O 'Consumption monitoring is required for Enphase Storage Systems. ` DATE: 06.11.2019 To learn more about Enphase offerings,visit enphase.com DESIGN BY:A.Y. LISTED ENFFiAS E. X2018 EnphaseE gy All reserved All Vademarkc or brads,Il is dUcumenl areregatered by their epeciNe ame EN PHASE CHECKED BY: M.M. To learn more about Enphase offerings,visit enphase.com V 20190&02 V REVISIONS 6 R-003.00 A as B as C ax D as E as F as G as H SHEET 12 A B C D E F G H sV NM©D O® INSIGHT INTRODUCING SUNPORTTm CARPORT SYSTEM A solar carport,canopy and power CONTRACTOR plant all rolled into one! — _ INSIGHT SOW 2 The evolution of solar carport design j PHONE: (413)3381555 has yielded a leaner,more cost-effective ADDRESS:89 MARKET STREET P NORTHAMPTON,MAOID6D structure that can deliver both vehicle LIC.NO.: protection and solar power generation. HIC.NO.: MA 192102 ELE.NO.: UNAUTHOR ZED USE OF THIS The SunPort Carport System maximizes energy harvesting and minimizes structural weight with DRAWING SET tMTHOUT WRITTEN PERMISSM FROM CONTRACTOR IS IN its all-aluminum construction. With its long-span truss,the SB Coo Triangular Beam the SunPort VIOLATION OF Us,COPYRIGHT LAWS 3J p J AND WILL BE SUBJECT TO CML 3 Carport System has been designed to span up to 25 feet,requiring fewer columns which reduces DAM DES AND PROSECUTIONS. materials and installation costs without impacting the structural integrity of the overall system. NEW PV SYSTEM:11.340 kWp The SunPort Carport System has BISHOP been engineered to resist any site-specific wind,snow and RESIDENCE seismic forces with a wide variety 241 HAYDENVILLE RD of anchoring options available. LEEDS,MA 01053 Its light construction reduces APN:NHAMM:0006B:0043L:0001 4 stress on the foundations and saves on transportation cost. ENGINEER OF RECORD And its elegant design is a cost- effective structure that can deliver both vehicle protection and solar power plant performance. Combine all this with SunModo's Rails and Mounting Clamp solutions,you have a hassle-free one- stop-shopping solar installation solution. When the parking lot is the only viable option for solar installation,We Got Your Rack!'" Features&Benefits: 5 PAPER SIZE 11',17'(ANSI BI • Provides valuable shade for vehicle protection while harvesting solar energy. RESOURCE DOCUMENT • Easy-to-assemble design for fast installation. • Standard and custom carport canopy solutions. DATE: 06.11.2019 • A wide variety of anchoring options. DESIGN BY:A.Y. • Keeps the solar panels cooler and more efficient with airflow beneath the panels. CHECKEDBY: M.M. 6 REVISIONS SunModo Corp I Vancouver,WA 98682 1360-844-0048 Document Number D10074-VO04 102018-SunModo Corp. R-004.00 A B C D m E F G H SHEET''