Loading...
38A-109 (3) 35 VILLAGE HILL RD BP-2020-0034 GIs#: COMMONWEALTH OF MASSACHUSETTS Map:Block:38A- 109 CITY OF NORTHAMPTON Lot:-001 PERSONS CONTRACTING WITH UNREGISTERED CONTRACTORS Permit: Building DO NOT HAVE ACCESS TO THE GUARANTY FUND (MGL c.142A) Category: MIXED USE NEW BLDG BUILDING PERMIT, Permit# BP-2020-0034 Project# JS-2018-000815 Est.Cost: $3199912.50 Fee: $9498.60 PERMISSION IS HEREBY GRANTED TO: Const.Class: Contractor: License: Use Group: WESTERN BUILDERS INC 073697 Lot Size(sq.ft.): 17598.24 Owner: HOSPITAL HILL DEVELOPMENT LLC C/O MASSDEVELOPMENT LLC Zoning: PV(100)/SG b(100)/ Applicant. WESTERN BUILDERS INC AT. 35 VILLAGE HILL RD Applicant Address: Phone: Insurance: P O BOX 587 (413)467-9171 Workers Compensation GRANBYMA01033 ISSUED ON.1112012019 6.00:00 TO PERFORM THE FOLLOWING WORK: 3 LEVEL MIXED USE BUILDING, 1ST FLOOR OFFICES, 2ND & 3RD FLOOR RESIDENTIAL POST THIS CARD SO IT IS VISIBLE FROM THE STREET Inspector of Plumbing Inspector of Wiring D.P.W. Building Inspector Underground: Service: Meter: Footings: Rough: Rough: House# Foundation: Driveway Final: Final: Final: Rough Frame: Gas: Fire Department Fireplace/Chimney: Rough: Oil: Insulation: Final: Smoke: Final: THIS PERMIT MAY BE REVOKED BY THE CITY OF NORTHAMPTON UPON VIOLATION OF ANY OF ITS RULES AND REGULATIONS. Certificate of Occupancy Signature: FeeType: Date Paid: Amount: Building 11/20/2019 0:00:00 $9498.60 212 Main Street, Phone(413)587-1240, Fax:(413)587-1272 Louis Hasbrouck—Building Commissioner File#BP-2020-0034 APPLICANT/CONTACT PERSON WESTERN BUILDERS INC ADDRESS/PHONE P O BOX 587 GRANBY (413)467-9171 PROPERTY LOCATION 35 VILLAGE HILL RD MAP 38A PARCEL 109 001 ZONE PV000)/SG b(,100)/ THIS SECTION FOR OFFICIAL USE ONLY: PERMIT APPLICATION CHECKLIST ENCLOSED REQUIRED DATE ZONING FORM FILLED OUT Fee Paid Building;Permit Filled out Fee Paid Typeof Construction: 3 LEVEL MIXED USE BUILDING 1ST FLOOR OFFICES,2ND&3RD FLOOR RESIDENTIAL New Construction Non Structural interior renovations Addition to Existing Accessory Structure Building;Plans Included: Owner/Statement or License 073697 3 sets of Plans/Plot Plan THE FOLLOWING ACTION HAS BEEN TAKEN ON THIS APPLICATION BASED ON INFO.9MATION PRESENTED: ,,,Approved Additional permits required(see below) PLANNING BOARD PERMIT REQUIRED UNDER:§ Intermediate Project: Site Plan AND/OR Special Permit With Site Plan Major Project: Site Plan AND/OR Special Permit With Site Plan ZONING BOARD PERMIT REQUIRED UNDER: § Finding Special Permit Variance* Received&Recorded at Registry of Deeds Proof Enclosed Other Permits Required: Curb Cut from DPW Water Availability Sewer Availability Septic Approval Board of Health Well Water Potability Board of Health Permit from Conservation Commission Permit from CB Architecture Committee Permit from Elm Street Commission Permit DPW Storm Water Management Demolition Delay III tell Signature of Building Official Date Note: Issuance of a Zoning permit does not relieve a applicant's burden to comply with all Zoning requirements and obtain all required permits from Board of Health,Conservation Commission,Department of public works and other applicable permit granting authorities. * Variances are granted only to those applicants who meet the strict standards of MGL 40A.Contact Office of Planning&Development for more information. N a'6 2A� ) A01 . J 'C�+ Versionl.7 Commercial Building Permit May 15, 2000 --- _ _ Department use only City of Northampton � EC E+ / C s of P rmit: Building Department y L Cuv riveway Permit - 212 Main Street Sew r/Se tic Availability Room 100 JUL - 9 2011 at r/We I Availability Northampton, MA 01060 Two Sets f Structural Plans phone 413-587-1240 F x 4a ite tans e c IN�PF ,TiQNs ,NC�RTHA141'TC1N, Qtller Sp it APPLICATION TO CONSTRUCT, REPAIR, RENOVATE, CHANGE THE USE OR OCCUPANCY OF, OR DEMOLISH ANY BUILDING OTHER THAN A ONE OR TWO FAMILY DWELLING SECTION 1 -SITE INFORMATION 1.1 Property Address: This section to be completed by office 35 Village Hill Rd. Northampton MA Map 3 /� Lot 1 C)q Unit Zone Overlay District Elm St. District CB District SECTION 2-PROPERTY OWNERSHIP/AUTHORIZED AGENT 2.1 Owner of Record: The Community Builders, Inc. 185 Dartmouth St. Boston MA 02116 Name(Print) Current Mailing Address: (857) 221-8600 Signature Telephone 2.2 Authorized Agent: Ivey Bueno Name(Print) Current Mailing Address: (857) 221-8647 Signature Telephone SECTION 3-ESTIMATED CONSTRUCTION COSTS Item Estimated Cost(Dollars)to be Official Use Only completed by permit applicant 1. Building $2,351,450.4() (a) Building Permit Fee 2. Electrical $283802.00 (b) Estimated Total Cost of $3,199 912.50 ' Construction from 6 ' 3. PlumbingBuildin Permit Fee $258,872.00 9 4. Mechanical (HVAC) $ 220,843.00 $9,498.60 5. Fire Protection $ 84,945.00 6. Total = (1 +2 + 3 +4 + 5) $ 3,199,912.50 Check Number _ This Section For Official Use Only Building Permit Number Date Issued Signature: Building Commissioner/Inspector of Buildings Date Versionl.7 Commercial Building Permit May 15, 2000 SECTION 4-CONSTRUCTION SERVICES FOR PROJECTS LESS THAN 35,000 CUBIC FEET OF ENCLOSED SPACE Interior Alterations ❑ Existing Wall Signs ❑ Demolition❑ Repairs❑ Additions ❑ Accessory Building❑ Exterior Alteration ❑ Existing Ground Sign❑ New Signs ❑ Roofing❑ Change of Use❑ Other ❑ Brief Description 3 level mixed use building. I st floor Retail/Office units, Of Proposed Work: 2nd and 3rd floor both have (3) 1 bedrooms (2) 2 bedrooms SECTION 5-USE GROUP AND CONSTRUCTION TYPE USE GROUP(Check as applicable) CONSTRUCTION TYPE A Assembly ❑ A-1 ❑ A-2 ❑ A-3 ❑ 1A ❑ A-4 ❑ A-5 ❑ 113 ❑ B Business ❑ 2A ❑ E Educational ❑ 26 I ❑ F Factory ❑ F-1 ❑ F-2 ❑ 2C ❑ H High Hazard ❑ 3A ❑ Institutional ❑ 1-1 ❑ 1-2 ❑ 1-3 ❑ 313 ❑ M Mercantile ❑ 4 ❑ R Residential ❑ R-1 ❑ R-2 ED R-3 ❑ 5A ❑ S Storage ❑ S-1 ❑ S-2 ❑ 513 ❑ U Utility ❑ Specify: M Mixed Use ❑ Specify: Mercantile/ Business S Special Use ❑ Specify: COMPLETE THIS SECTION IF EXISTING BUILDING UNDERGOING RENOVATIONS,ADDITIONS AND/OR CHANGE IN USE Existing Use Group: Proposed Use Group: Existing Hazard Index 780 CMR 34): Proposed Hazard Index 780 CMR 34): SECTION 6 BUILDING HEIGHT AND AREA BUILDING AREA EXISTING PROPOSED NEW CONSTRUCTION OFFICE USE ONLY Floor Area per Floor(sf) 1 St 1 S` 5,707 2nd 2nd 5,062 3rd 3'd 5,062 4m 4th Total Area (so Total Proposed New Construction (sf) 15,831 Total Height(ft) Total Height ft 245 7. Water Supply(M.G.L. c. 40, § 54) 7.1 Flood Zone Information: 7.3 Sewage Disposal System: Public ✓❑ Private ❑ Zone Outside Flood Zone[Z] Municipal E] On site disposal system[:] Version 1.7 Commercial Building Permit May 15,2000 8. NORTHAMPTON ZONING Existing Proposed Required by Zoning This column to be filled in by Building Department Lot Size 18546sf 18546sf Frontage 214ft 214ft Setbacks Front Side L: R: L: R: Rear Building Height 0 245 Bldg. Square Footage 0 0 % 15831 100 Open Space Footage % (Lot area minus bldg&paved 18546 100 12839 69 parking) #of Parkin2 S aces 0 0 Fill: volume&Location 0 00 A. Has a Special Permit/Variance/Finding ever been issued for/on the site? NO O DON'T KNOW Q YES Q IF YES, date issued: IF YES: Was the permit recorded at the Registry of Deeds? NO O DON'T KNOW O YES O IF YES: enter Book Page and/or Document# B. Does the site contain a brook, body of water or wetlands? NO O DON'T KNOW O YES O IF YES, has a permit been or need to be obtained from the Conservation Commission? Needs to be obtained Q Obtained O , Date Issued: C. Do any signs exist on the property? YES O NO O IF YES, describe size, type and location: D. Are there any proposed changes to or additions of signs intended for the property ? YES O NO 0 IF YES, describe size, type and location: E. Will the construction activity disturb(clearing, grading,excavation, or filling) over 1 acre or is it part of a common plan that will disturb over 1 acre? YES O NO O IF YES,then a Northampton Storm Water Management Permit from the DPW is required. Version 1.7 Commercial Building Permit May 15, 2000 SECTION 9-PROFESSIONAL DESIGN AND CONSTRUCTION SERVICES-FOR BUILDINGS AND STRUCTURES SUBJECT TO CONSTRUCTION CONTROL PURSUANT TO 780 CMR 116(CONTAINING MORE THAN 35,000 C.F.OF ENCLOSED SPACE) 9.1 Registered Architect: Davis Square Architects Not Applicable ❑ Name(Registrant): 240 A Elm Street Somerville, MA 02144 Registration Number Address (617) 628-5760 Expiration Date Signature Telephone 9.2 Registered Professional Engineer(s): The Berkshire Design Group, Inc. Civil/Site/Landscape Name Area of Responsibility 4 Allen Place, Northampton MA 01060 Address Registration Number (413) 582-7000 Signature Telephone Expiration Date Souza, True and Partners Inc Structural Name Area of Responsibility 265 Winter Street, 3rd floor, Waltham MA 02451 Address Registration Number (617) 926-6100 Signature Telephone Expiration Date Building Engineering Resources, Inc. Mechanical, Electrical, Plumbing Name Area of Responsibility 66 Main Street, North Easton, MA 02356 34989, 38119 Address Registration Number (508) 230-0260 06/30/2020 Signature Telephone Expiration Date Name Area of Responsibility Address Registration Number Signature Telephone Expiration Date 9.3 General Contractor Western Builders Not Applicable ❑ Company Name: Mark Follet Responsible In Charge of Construction 73 Pleasant Street Granby, MA 01033 Address (413) 537-1683 Signature Telephone CONTINUATION OF PREVIOUS PAGE FOR ENGINEERSr Version 1.7 Commercial Building Permit May 15,2000 Crllf'�� v/n i /- (7 )r SECTION 9-PROFESSIONAL DESIGN AND CONSTRUCTION SERVICES -FOR BUILDINGS AND STRUCTURES SU ECT TO CONSTRUCTION CONTROL PURSUANT TO 780 CMR 116(CONTAINING MORE THAN 35,000 C.F.OF ENCLOSED SPACE) 9.1 Registered Architect: Davis Square Architects Not Applicable ❑ Name(Registrant): 240 A Elm Street Somerville, MA 02144 Registration Number Address (617) 628-5760 Expiration Date Signature Telephone 9.2 Registered Professional Engineer(s): The Berkshire Design Group, Inc. Civil/Site/Landscape Name Area of Responsibility 4 Allen Place,Northampton MA 01060 Address Registration Number (413) 582-7000 Signature Telephone Expiration Date Souza, True and Partners Inc Structural Name Area of Responsibility 265 Winter Street, 3rd floor, Waltham MA 02451 Address Registration Number (617) 926-6100 Signature Telephone Expiration Date Building Engineering Resources, Inc. Mechanical Name Area of Responsibility 66 Main Street, North Easton, MA 02356 34989 Address Registration Number (508) 230-0260 06/30/2020 Signature Telephone Expiration Date Building Engineering Resources, Inc. Electrical Name Area of Responsibility 38119 Address Registration Number Signature Telephone Expiration Date 9.3 General Contractor Western Builders Not Applicable ❑ Company Name: Mark Follet Responsible In Charge of Construction 73 Pleasant Street Granby, MA 01033 Address (413) 537-1683 Signature Telephone CONTINUATION OF PREVIOUS PAGE FOR ENGINEERS Versionl.7 Commercial Building Permit May 15,2000 SECTION 9- PROFESSIONAL DESIGN AND CONSTRUCTION SERVICES- FOR BUILDINGS AND STRUCTURES SUBJECT TO CONSTRUCTION CONTROL PURSUANT TO 780 CMR 116(CONTAINING MORE THAN 35,000 C.F. OF ENCLOSED SPACE) 9.1 Registered Architect: Davis Square Architects Not Applicable ❑ Name(Registrant): 240 A Elm Street Somerville,-MA 02144 Registration Number Address (617) 628-5760 Expiration Date Signature Telephone 9.2 Registered Professional Engineer(s): The Berkshire Design Group, Inc. Civil/Site/Landscape Name Area of Responsibility L4,Allen Place, Northampton MA 01060 Address Registration Number (413) 58277000 Signature Telephone Expiration Date Souza, True and Partners Inc Structural Name Area of Responsibility 265 Winter Street, 3rd floor, Waltham MA 02451 Address Registration Number (61 9-6100 _... — _ --- Signature Telephone Expiration Date Building Engineering Resources, Inc. :Mechanical Name Area of Responsibility 66 Main Street, North Easton,MA 023563498 89 Address Registration Number (508) 230-0260 06/30/2020 Signature Telephone Expiration Date Building Engineering Resources, Inc. Electrical Name Area of Responsibility 38119 Address Registration Number Signature Telephone Expiration Date 9.3 General Contractor Western Builders Not Applicable ❑ Company Name: Mark Follet.____ Responsible In Charge of Construction 73 Pleasant Street Granby, MA 01033 Address 0413) 537-1683 Signature Telephone Version 1.7 Commercial Building Permit May 15,2000 SECTION 10-STRUCTURAL PEER REVIEW(780 CMR 110.11) Independent Structural Engineering Structural Peer Review Required Yes O No O SECTION 11 -OWNER AUTHORIZATION-TO BE COMPLETED WHEN OWNERS AGENT OR CONTRACTOR APPLIES FOR BUILDING PERMIT I Ivey Bueno as Owner of the subject property hereby authorize Western Builders, Inc. to act on my behalf, in all matters relative to work authorized by this building permit application. Signature of Owner Date Mark Follett as Owner/Authorized Agent hereby declare that the statements and information on the foregoing application are true and accurate, to the best of my knowledge and belief. Signed under the pains and penalties of perjury. Mark Follett Print Name 00, 07/09/2019 Signature of Owner/Agent Date SECTION 12-CONSTRUCTION SERVICES 10.1 Licensed Construction Supervisor: Not Applicable ❑ Name of License Holder: Lance Berneche CS-073697 License Number 48 Fletcher Circle Chicopee MA 01020 07/18/2020 Address Expiration Date (413) 265-5600 Signature Telephone SECTION 13-WORKERS' COMPENSATION INSURANCE AFFIDAVIT(M.G.L. c. 152,§25C(6)) Workers Compensation Insurance affidavit must be completed and submitted with this application. Failure to provide this affidavit will result in the denial of the issuance of the building permit. Signed Affidavit Attached Yes ® No City of Northampton 212 Main Street, Northampton, MA 01060 Solid Waste Disposal Affidavit In accordance of the provisions of MGL c 40, S54, I acknowledge that as a condition of the building permit all debris resulting from the construction activity governed by this Building Permit shall be disposed of in a properly licensed solid waste disposal facility, as defined by MGL c 111 , S 150A. Address of the work: 35 village Hill Rd The debris will be transported by: Associated Building Wreckers The debris will be received by: Western Recycling, Old Boston Rd, Wilboraham MA Building permit number: Name of Permit Applicant Western Builders, Inc. 07/08/19 Date Signature of Permit Applicant The Commonwealth of Massachusetts Department of Industrial Accidents I Congress Street,Suite 100 Boston, MA 02114-2017 www mass gov/dia Workers'Compensation Insurance Affidavit:Builders/Contractors/Electricians/Plumbers. TO BE FILED WITH THE PERMITTING AUTHORITY. Applicant Information Please Print Leeibly Name(Business/Organization/Individual):Western Builders, Inc. Address:73 Pleasant St. City/State/Zip:Granby MA 01033 Phone#:413-467-9171 Are you an employer?Check the appropriate box: Type of project(required): 1.❑1 am a employer with employees(full and/or part-time).* 7. ✓❑New construction 2.❑I am a sole proprietor or partnership and have no employees working for me in 8. ❑Remodeling any capacity.[No workers'comp.insurance required.] 9. ❑Demolition ❑I am a homeowner doing all work myself.[No workers'comp.insurance required.]t ❑4.F-1I am a homeowner and will be hiring contractors to conduct all work on my property. I will 10 Building addition ensure that all contractors either have workers'compensation insurance or are sole 11.❑Electrical repairs or additions proprietors with no employees. 12.E]Plumbing repairs or additions 5.Q I am a general contractor and I have hired the sub-contractors listed on the attached sheet. 13.E:]Roof repairs These sub-contractors have employees and have workers'comp.insurance.: 6.❑We are a corporation and its officers have exercised their right of exemption per MGL c. 14.❑Other 152,§1(4),and we have no employees.[No workers'comp.insurance required.] *Any applicant that checks box#1 must also fill out the section below showing their workers'compensation policy information. t Homeowners who submit this affidavit indicating they are doing all work and then hire outside contractors must submit a new affidavit indicating such. :Contractors that check this box must attached an additional sheet showing the name of the sub-contractors and state whether or not those entities have employees. If the sub-contractors have employees,they must provide their workers'comp.policy number. I am an employer that is providing workers'compensation insurance for my employees. Below is the policy and job site information. Insurance Company Name:Travelers Indemnity Co. of CT Policy#or Self-ins.Lic.#: UB-61<239300 Expiration Date:6/1/20 Job Site Address:35 Village Hill Rd City/State/Zip:Northampton MA 0106 Attach a copy of the workers'compensation policy declaration page(showing the policy number and expiration date). Failure to secure coverage as required under MGL c. 152,§25A is a criminal violation punishable by a fine up to$1,500.00 and/or one-year imprisonment,as well as civil penalties in the form of a STOP WORK ORDER and a fine of up to$250.00 a day against the violator.A copy of this statement may be forwarded to the Office of Investigations of the DIA for insurance coverage verification. I do hereby certify under thepaup and e of peryury that the information provided above is true and correct. Si nature: Date: 07/08/2019 Phone#:413-537-1683 Official use ontj% Do not write in this area, to be completed by city or town official. City or Town: Permit/License# Issuing Authority(circle one): I. Board of Health 2. Building Department 3. City/Town Clerk 4.Electrical Inspector 5.Plumbing Inspector 6.Other Contact Person: Phone#: Initial Construction Control Document To be submitted with the building permit application by a y Registered Design Professional for work per the Ninth Edition of the Massachusetts State Building Code, 780 CMR, Section 107 Project Title: Village Hill Date:June 5,2019 Property Address: 35 Village Road-Northhampton,MA Project: Check(X)One or Both as applicable: [X] New Construction [ J Existing Construction Project Description: New 3-story commercial building and (12)units of residential apartments. 1,Steven A.Karan,PE,MA Registration Number:34989, Expiration Date:06/302020,am a registered design professional, and I have prepared or directly supervised the preparation of all design plans,computations and specifications concerningJ: [ ] Architectural [ ] Structural [X] Mechanical [ ] Fire Protection [ ] Electrical [ ] Other: for the above named project and that to the best of my knowledge,information,and belief such plans,computations and specifications meet the applicable provisions of the Massachusetts State Building Code,(780 CMR),and accepted engineering practices for the proposed project. I understand and agree that I(or my designee)shall perform the necessary professional services and be present on the construction site on a regular and periodic basis to: 1. Review,for conformance to this Code and the design concept,shop drawings,samples and other submittals by the contractor in accordance with the requirements of the construction documents. 2. Perform the duties for registered design professionals in 780 CMR Chapter 17,as applicable. 3. Be present at intervals appropriate to the stage of construction to become generally familiar with the progress and quality of the work and to determine if the work is being performed in a manner consistent with the approved construction documents and this Code. Nothing in this document relieves the contractor of its responsibility regarding the provisions of 780 CMR 107. When required by the Building Official,I shall submit Field/Progress Reports(see Item 3.)together with pertinent comments,in a form acceptable to the Building Official. Upon completion of the work,I shall submit to the Building Official a'Final Construction Control Document'. Enter in the space to the right a"wet" or electronic signature and seal: a STEVENR v MECHANICAL No cases A ENG Phone Number: (508) 230-0260 Email:skaran@ber-engineering.com Building Official Use Only Building Official Name: Permit No.: Date: Version 01 01 2018 Initial Construction Control Document To be submitted with the building permit application by a ' Registered Design Professional for work per the Ninth Edition of the Massachusetts State Building Code, 780 CMR, Section 107 Project Title: Village Hill Date:June 5,2019 Property Address: 35 Village Road-Northhampton,MA Project: Check(X)One or Both as applicable: [X] New Construction [ ] Existing Construction Project Description: New 3-story commercial building and(12)units of residential apartments. I,Steven A.Karan,PE, MA Registration Number:34989,Expiration Date:0400/2020,am a registered design professional, and I have prepared or directly supervised the preparation of all design plans,computations and specifications concerning': [ ] Architectural [ ] Structural [ ] Mechanical [ ] Fire Protection [ ] Electrical [X] Other.Plumbing for the above named project and that to the best of my knowledge,information,and belief such plans,computations and specifications meet the applicable provisions of the Massachusetts State Building Code,(780 CMR),and accepted engineering practices for the proposed project. I understand and agree that I(or my designee)shall perform the necessary professional services and be present on the construction site on a regular and periodic basis to: 1. Review,for conformance to this Code and the design concept,shop drawings,samples and other submittals by the contractor in accordance with the requirements of the construction documents. 2. Perform the duties for registered design professionals in 780 CMR Chapter 17,as applicable. 3. Be present at intervals appropriate to the stage of construction to become generally familiar with the progress and quality of the work and to determine if the work is being performed in a manner consistent with the approved construction documents and this Code. Nothing in this document relieves the contractor of its responsibility regarding the provisions of 780 CMR 107. When required by the Building Official,I shall submit Field/Progress Reports(see Item 3.)together with pertinent comments,in a form acceptable to the Building Official. Upon completion of the work,I shall submit to the Building Official a'Final Construction Control Document'. Enter in the space to the right a"wet" or electronic signature and seal: OF Af4Ss STEVEN A. u MECW4NICAL V Wo 3e98� FF S L ANG Phone Number: (508) 230-0260 Email:skaran@ber-engineering.com Building Official Use Only Building Official Name: Permit No.: Date: Version 01 01 2018 Initial Construction Control Document To be submitted with the building permit application by a j Registered Design Professional for work per the Ninth Edition of the Massachusetts State Building Code, 780 CMR, Section 107 Project Title: Village Hill Date:June 5,2019 Property Address: 35 Village Road-Northhampton,MA Project: Check(X)One or Both as applicable: [X] New Construction [ ] Existing Construction Project Description: New 3-story commercial building and(12)units of residential apartments. 1,Marc R Plante,PE,MA Registration Number:38119,Expiration Date:06/31020,am a registered design professional, and I have prepared or directly supervised the preparation of all design plans,computations and specifications concerning: [ J Architectural [ ] Structural [ ] Mechanical [ J Fire Protection [X] Electrical [ ] Other: for the above named project and that to the best of my knowledge,information,and belief such plans,computations and specifications meet the applicable provisions of the Massachusetts State Building Code,(780 CMR),and accepted engineering practices for the proposed project. I understand and agree that I(or my designee)shall perform the necessary professional services and be present on the construction site on a regular and periodic basis to: 1. Review,for conformance to this Code and the design concept,shop drawings,samples and other submittals by the contractor in accordance with the requirements of the construction documents. 2. Perform the duties for registered design professionals in 780 CMR Chapter 17,as applicable. 3. Be present at intervals appropriate to the stage of construction to become generally familiar with the progress and quality of the work and to determine if the work is being performed in a manner consistent with the approved construction documents and this Code. Nothing in this document relieves the contractor of its responsibility regarding the provisions of 780 CMR 107. When required by the Building Official,I shall submit Field/Progress Reports(see Item 3.)together with pertinent comments,in a form acceptable to the Building Official. Upon completion of the work,I shall submit to the Building Official a'Final Construction Control Document'. Enter in the space to the right a"wet" or electronic signature and seal: Phone Number. (508) 230-0260 Email:mplantefber-MgineerinQ.com Building Official Use Only Building Official Name: Permit No: Date: Version 01 01 2018 Fee,y' I Initial Construction Control Document To be submitted with the building permit application by a ' Registered Design Professional for work per the Ninth Edition of the Massachusetts State Building Code, 780 CMR, Section 107 Project Title: Village Hill Date:June 5,2019 Property Address: 35 Village Road-Northhampton,MA Project: Check(X)One or Both as applicable: [X] New Construction [ ] Existing Construction Project Description: New 3-story commercial building and(12)units of residential apartments. 1,Steven A.Karan,PE,MA Registration Number:34989,Expiration Date:06134/2020,am a registered design professional, and I have prepared or directly supervised the preparation of all design plans,computations and specifications concerning': [ ] Architectural [ ] Structural [X] Mechanical [ ] Fire Protection [ ] Electrical [ ] Other: for the above named project and that to the best of my knowledge,information,and belief such plans,computations and specifications meet the applicable provisions of the Massachusetts State Building Code,(780 CMR),and accepted engineering practices for the proposed project. I understand and agree that I(or my designee)shall perform the necessary professional services and be present on the construction site on a regular and periodic basis to: 1. Review,for conformance to this Code and the design concept,shop drawings,samples and other submittals by the contractor in accordance with the requirements of the construction documents. 2. Perform the duties for registered design professionals in 780 CMR Chapter 17,as applicable. 3. Be present at intervals appropriate to the stage of construction to become generally familiar with the progress and quality of the work and to determine if the work is being performed in a manner consistent with the approved construction documents and this Code. Nothing in this document relieves the contractor of its responsibility regarding the provisions of 780 CMR 107. When required by the Building Official,I shall submit Field/Progress Reports(see Item 3.)together with pertinent comments,in a form acceptable to the Building Official. Upon completion of the work,I shall submit to the Building Official a'Final Construction Control Document'. Enter in the space to the right a"wet"or electronic signature and seal: a`ZK OF y„ STEVEN A yGP KARAN v MEO ANICAL „ No 34989 Q Phone Number: (508)230-0260 Email:skaranfter-en 'nom eering.coin Building Official Use Only Building Official Name: Permit No.: Date.- Version ate:Version 01 01 2018 <c 3 A Initial Construction Control Document � ent To be submitted with the building permit application by a Registered Design Professional for work per the Ninth Edition of the Massachusetts State Building Code, 780 CMR, Section 107 Project Title: Village Hill Date:June 5,2019 Property Address: 35 Village Road-Northhampton,MA Project: Check(X)One or Both as applicable: [X] New Construction [ ] Existing Construction Project Description: New 3-story commercial building and(12)units of residential apartments. 1,Marc R Plante,PE,MA Registration Number:38119,Expiration Date:06%2020,am a registered design professional, and I have prepared or directly supervised the preparation of all design plans,computations and specifications concerning': [ ] Architectural [ ] Structural [ ] Mechanical [ ] Fire Protection [X] Electrical ( ] Other: for the above named project and that to the best of my knowledge,information,and belief such plans,computations and specifications meet the applicable provisions of the Massachusetts State Building Code,(780 CMR),and accepted engineering practices for the proposed project. I understand and agree that I(or my designee)shall perform the necessary professional services and be present on the construction site on a regular and periodic basis to: 1. Review,for conformance to this Code and the design concept,shop drawings,samples and other submittals by the contractor in accordance with the requirements of the construction documents. 2. Perform the duties for registered design professionals in 780 CMR Chapter 17,as applicable. 3. Be present at intervals appropriate to the stage of construction to become generally familiar with the progress and quality of the work and to determine if the work is being performed in a manner consistent with the approved construction documents and this Code. Nothing in this document relieves the contractor of its responsibility regarding the provisions of 780 CMR 107. When required by the Building Official,I shall submit Field/Progress Reports(see Item 3.)together with pertinent comments,in a form acceptable to the Building Official. Upon completion of the work,I shall submit to the Building Official a'Final Construction Control Document`. Enter in the space to the right a"wet"or electronic signature and seal: vk 0;eta RC R. �yL PtAtiTc C ELECTrJiC _ cc Q. A F�SIC:q_ Phone Number: (508)230-0260 Email:mplante@ber-engineering.com Building Official Use Only Building Official Name: Permit No.: Date: Version 01 01 2018 Initial Construction Control Do � current IR To be submitted with the building permit application by a Registered Design Professional for work per the Ninth Edition of the Massachusetts State Building Code, 780 CMR, Section 107 Project Title: Village Hill Date:June 5,2019 Property Address: 35 Village Road-Northhampton,MA Project. Check(X)One or Both as applicable: [X] New Construction [ ] Existing Construction Project Description: New 3-story commercial building and(12)units of residential apartments. 1,Steven A.Karan,PE,MA Registration Number:34989,Expiration Date:06/30/2020,am a registered design professional, and I have prepared or directly supervised the preparation of all design plans,computations and specifications concerning': [ ] Architectural j ] Structural [ ] Mechanical [ ] Fire Protection [ ] Electrical [X] Other:Plumbing for the above named project and that to the best of my knowledge,information,and belief such plans,computations and specifications meet the applicable provisions of the Massachusetts State Building Code,(780 CMR),and accepted engineering practices for the proposed project. I understand and agree that I(or my designee)shall perform the necessary professional services and be present on the construction site on a regular and periodic basis to: 1. Review,for conformance to this Code and the design concept,shop drawings,samples and other submittals by the contractor in accordance with the requirements of the construction documents. 2. Perform the duties for registered design professionals in 780 CMR Chapter 17,as applicable. 3. Be present at intervals appropriate to the stage of construction to become generally familiar with the progress and quality of the work and to determine if the work is being performed in a manner consistent with the approved construction documents and this Code. Nothing in this document relieves the contractor of its responsibility regarding the provisions of 780 CMR 107. When required by the Building Official,I shall submit Field/Progress Reports(see Item 3.)together with pertinent comments,in a form acceptable to the Building Official. Upon completion of the work,I shall submit to the Building Official a'Final Construction Control Document'. Enter in the space to the right a"wet" or electronic signature and seal: a��H of�qs STEVEN A. ti Z= KAAAN ^. u MECHANICAL Dlo.U989 'cF Lt Phone Number: (508) 230-0264 Email:skaran@ber-engineering.com Building Official Use Only Building Official Name: Permit No: Date: Version 01 01 2018 Initial Construction Con � trol Document To be submitted with the building permit application by a Registered Design Professional for work per the Ninth Edition of the Massachusetts State Building Code, 780 CMR, Section 107 Project Title: Village Hill Date:June 5,2019 Property Address: 35 Village Road-Northhampton,MA Project: Check(X)One or Both as applicable:[X] New Construction [ ] Existing Construction Project Description: New 3-story commercial building and(12)units of residential apartments. 1,Steven A.Karan,PE, MA Registration Number:34989,Expiration Date:06/342020,am a registered design professional, and I have prepared or directly supervised the preparation of all design plans,computations and specifications concerning': [ ] Architectural [ ] Structural [ ] Mechanical [X] Fire Protection [ ] Electrical [ ] Other: for the above named project and that to the best of my knowledge,information,and belief such plans,computations and specifications meet the applicable provisions of the Massachusetts State Building Code, (780 CMR),and accepted engineering practices for the proposed project. I understand and agree that I(or my designee)shall perform the necessary professional services and be present on the construction site on a regular and periodic basis to: 1. Review,for conformance to this Code and the design concept,shop drawings,samples and other submittals by the contractor in accordance with the requirements of the construction documents. 2. Perform the duties for registered design professionals in 780 CMR Chapter 17,as applicable. 3. Be present at intervals appropriate to the stage of construction to become generally familiar with the progress and quality of the work and to determine if the work is being performed in a manner consistent with the approved construction documents and this Code. Nothing in this document relieves the contractor of its responsibility regarding the provisions of 780 CMR 107. When required by the Building Official,I shall submit Field/Progress Reports(see Item 3.)together with pertinent comments,in a form acceptable to the Building Official. Upon completion of the work,I shall submit to the Building Official a'Final Construction Control Document'. Enter in the space to the right a"wet" or electronic signature and seal: 000F A STEVEN A tiN U MECHAWAL y 40 34969 ST1:P�OQ NAL t't'� Phone Number: (508)230-0260 Email:skaran®ber-ogineering.com Building Official Use Only Building Official Name: Permit No.: Date: Version 01 01 2018 16-Jul-19 Proj:17031.02 Name:35 Village Hill Road 35 Village Hill - IECC C402.1.3 Compliance IECC Assembly Design Performance Wall R-value: 20.0 E1 27.7 Vass E3 29.0 'ass Fenestration U-value:0.45 C1 0.24 'ass Operable (C402.4) C2 0.24 ass C3 0.24 'ass Storefront Door U-value:0.77 Storefront Door 0.43 (C402.4) 'ass Slab R-value: 10.0 Concrete Slab 10.32 'ass Ceiling Space above conditioned (C402.2.4) N/A Initial Construction Control Doc � ument To be submitted with the building permit application by a Registered Design Professional ` for work per the Ninth Edition of the Massachusetts State Building Code, 780 CMR, Section 107 Project Title: Village Hill Date:June 5,2019 Property Address: 35 Village Road-Northhampton,MA Project: Check(X)One or Both as applicable: [X] New Construction [ ] Existing Construction Project Description: New 3-story commercial building and(12)units of residential apartments. I,Steven A.Karan,PE, MA Registration Number:34989,Expiration Date:0000/2020,am a registered design professional, and I have prepared or directly supervised the preparation of all design plans,computations and specifications concerning': [ ] Architectural [ ] Structural [ ] Mechanical [X] Fire Protection [ ] Electrical [ ] Other: for the above named project and that to the best of my knowledge,information,and belief such plans,computations and specifications meet the applicable provisions of the Massachusetts State Building Code,(780 CMR),and accepted engineering practices for the proposed project. I understand and agree that I(or my designee)shall perform the necessary professional services and be present on the construction site on a regular and periodic basis to: 1. Review,for conformance to this Code and the design concept,shop drawings,samples and other submittals by the contractor in accordance with the requirements of the construction documents. 2. Perform the duties for registered design professionals in 780 CMR Chapter 17,as applicable. 3. Be present at intervals appropriate to the stage of construction to become generally familiar with the progress and quality of the work and to determine if the work is being performed in a manner consistent with the approved construction documents and this Code. Nothing in this document relieves the contractor of its responsibility regarding the provisions of 780 CMR 107. When required by the Building Official,I shall submit Field/Progress Reports(see Iters 3.)together with pertinent comments,in a form acceptable to the Building Official. Upon completion of the work,I shall submit to the Building Official a'Final Construction Control Document'. Enter in the space to the right a"wet" or electronic signature and seal: �,I ti of STEVEN A �G a KAHAN MECHANICAL r; Ab 34989 G�9�a�ST1P�O�4�Q Phone Number: (508) 230-0260 Email:skaran@ber-engineerinjzxom Building Official Use Only Building Official Name: Permit No.: Date: Version 01 01 2018 MEMORANDUM TO: Debin Bruce,Chair, Planning reer,FR: David K. Veleta, P.E., City Engi DA: January 9, 2018 RE: File: 35 Village Hill Road—3-story Multi-Use Building—Major Site Plan Map ID: 38A-109 CC: file The Department of Public Works has reviewed the above referenced application for the following items: Traffic: Utilities: x Volume& Impact on City Street x Sanitary Sewer x Roadway Capacity x Water x Adequacy of City Road Construction x Drainage Into City Stormwater System x Site Distances x Capacity of Stormwater Line x Parking x Northampton Stormwater Permit x Driveway Openings NPDES Phase Il Compliance x Other: The Department of Public Works has the following comments: No Concerns,project will not have an impact on any items reviewed Trak Study is required Roadway does not have adequate capacity to handle the additional traffic Roadway is not adequately constructed to handle proposed increase in traffic Site Distances are not adequate for proposed project Parking spaces do not meet minimum requirements Parking spaces are too close to driveway opening Driveway openings are not adequate for proposed use Sanitary Sewer line is not adequately sized for proposed use Sewer line connection is not properly shown Water line is not adequately sized for proposed use Water line connection is not properly shown City stormwater system is not adequate to handle increase in drainage Stormwater system does not meet minimum requirements for reduction of Total Suspended Solids {TSS} Northampton Stormwater Management Permit has not been approved or conditions for approved permit have not been met x Other Comments: General • These review comments are based on plans dated December 8, 2017 with revisions on sheets L.3 and L.6 dated December 26, 2017. The cover page is stamped by Mark 0035 Village Hill Road Major Site_PB.doc Page 1 of 2 Darnold, P.E. and Peter Wells, RLA. • Based on the comments below and any conditions required by a Planning permit approval,the applicant shall submit revised final construction plans, signed and sealed by a Massachusetts registered P.E. on all applicable plan sheets, to the DPW for review and approval at least 15 days prior to the issuance of any City building or construction permits. • A combined Stormwater Permit application for this project and the proposed apartments off Olander Drive was submitted. The DPW has determined that a Stormwater Permit is not required for the proposed 35 Village Hill Road project. Sidewalk • A brick sidewalk that connects with 12-foot radii to the public sidewalk along Village Hill Road is proposed. Approximately three feet of this sidewalk is within the ROW with an opening over 25 feet wide. The designer should reduce this radius to a maximum of 3 feet. The DPW does not typically allow walkway material other than concrete or bituminous concrete but will make an exception for this minor connection with the understanding that maintenance and repair of the entire brick sidewalk shall be the responsibility of the property owner. Water • Connection to an existing 6-inch water stub with shutoff valve is proposed. It is assumed that fire protection is required for the building, and no domestic water line is shown. The size and type of domestic service shall be shown on the plans. It shall branch off the 6- inch line and be provided with a shutoff valve outside the building. Drainage • The Rain Garden detail, 6/L.5,needs further clarification. o A"6-inch perforated drain pipe/tie into CB" for the round inlet structure is called out. Is this correct?The plans indicate 6-inch PVC pipe in and an unspecified pipe out. Please revise the detail and plan as appropriate. o Specifications for the 24-inch planting media and mulch shall be provided. o Test pits to determine the soil characteristics underlying the proposed rain gardens is required in order to verify their functionality. • Prior to issuance of a Building Permit,the applicant shall record an executed Stormwater Operation, Maintenance, and Inspection Agreement that is binding on all subsequent owners of land served by the private stormwater management facility by recording it in the land records of the Registry of Deeds. This agreement must be approved by the Northampton DPW prior to final signatures. Tree Protection • There are numerous well-established trees on the lot that could be impacted by construction. The plans shall indicate those trees that are to be protected throughout construction, and shall provide tree protection details that conform to ANSI 300 Standards, Part 5. The applicant shall confer with the Tree Warden if there are any questions regarding what is required. 0035 village Hill Road_Major Site_PB.doe Page 2 of 2 Planning - Decision City of Northampton Hearing No.: PLN-2018-0033 Date: January 23. 2018 APPLICATION TYPE SUBMISSION DATE PB 40R Review 12/12/2017 Applicant's Name: Owner's Name: NAME NAME Community Builders,Inc. HOSPITAL HILL DEVELOPMENT LLC C/O MA ADDRESS ADDRESS 322 Main Street 160 FEDERAL ST TOWN. STATE. ZIP CODE. TOWN. STATE. ZIP CODE SPRINGFIELD MA 01105-2408 BOSTON MA 02110 PHONE NO FAX NO.. PHONE NO FAX NO 737-0207 EMAIL ADDRESS EMAIL ADDRESS. Site Information: Surveyor's Name: STREET NO., SITE ZONING COMPANY NAME: VILLAGE HILL RD PV(100)/SG b(100)/ TOWN ACTION TAKEN. ADDRESS. NORTHAMPTON MA 01060 Approved With Conditions MAP BLOCK LOT MAP DATE. SECTION OF BYLALV 38A 109 001 350-20:Smart Growth Overlay District TOWN STATE ZIP CODE Book Page PHONE NO FAX.NO-. EMAIL ADDRESS NATURE OF PROPOSED WORK Construction of a 3 story 15,000+square foot multi-use building with 12 residential units and approximately 3,000 sf of commercial space. HARDSHIP CONDITION OF APPROVAL. 1) Prior to any site work, the applicant must have all tree protection measures installed and inspected by the City. Tree protection must conform to ANSI 300 Standards,Part 5. 2).At least 15 days prior to request for a building permit, the applicant shall submit revised final construction plans,signed and sealed by a Massachusetts registered P.E. on all applicable plan sheets, to the Department of Public Works(DPW)for review and approval at least 15 days prior to the issuance of any City building or construction permits. All revised plans shall include test pit results of soils where the proposed rain garden is located and detail planting medium shall be provided 3).Prior to issuance of a Building Permit, the applicant shall record an executed Stormwater Operation, Maintenance,and Inspection Agreement that is binding on all subsequent owners of land served by the private storm water management facility by recording it in the land records of the Registry of Deeds. This agreement must be approved by the Northampton DPW prior to final signatures. 4).Prior to issuance of a Building Permit, the applicant shall record an executed Stormwater Operation, Maintenance,and inspection Agreement that is binding on all subsequent owners of land served by the private storm water management facility by recording it in the land records of the Registry of Deeds. This agreement must be approved by the Northampton DPW prior to final signatures. 5).All water lines shall meet the Department of Public Works standards for size and connections. 6).Prior to Certificate of Occupancy,all tree replacement requirements shall be completed. FINDINGS The Planning Board approved the application under§350-20.18 Village Hill Sustainable Growth Overlay(MGL Chapter 40R)based on the following information and plans submitted with the application: 1. Site Plan Application Supplement 40 R Compliance statements Dated December 8, 2017. 2. "Village Hill Site Plan Review",By the Berkshire Design Group, Dated December 8, 2017 Sheets L3, L4, L5(rev. 12/26/17,. Sheets L6, L7 Dated 12/26/17. 3. Elevations and Renderings by Davis Square Architects, dated December 8,2017. The Planning Board approved the 40R application upon determining that the requirements within§350-20.18 had been met,including evaluation of uses, density, design,and accessibility and affordability. A total of—60%of the units will be affordable with the remaining GeoTMS®2018 Des Lauriers Municipal Solutions,Inc. Planning -Decision City of Northampton Hearing No.: PLN-2018-0033 Date: January 23, 2018 40%targeted to workforce housing,meeting 120%of AMI. COULD NOT DEROGATE BECAUSE: FILING DEADLINE: MAILING DATE. HEARING CONTINUED DATE. DECISION DRAFT BY. APPEAL DATE: 12/12/2017 114/2018 411112018 REFERRALS IN DATE: HEARING DEADLINE DATE: HEARING CLOSE DATE: FINAL SIGNING BY. APPEAL DEADLINE. 12128/2017 41112018 111112018 411112018 2/12/2018 FIRST ADVERTISING DATE. HEARING DATE: VOTING DATE. DECISION DATE: 12/2812017 111112018 1/11/2018 1123/2018 SECOND ADVERTISING DATE: HEARING TIME. VOTING DEADLINE: DECISION DEADLINE, 1/4/2018 7:00 PM 4/1112018 4/11/2018 MEMBERS PRESENT: VOTE: Samuet Taylor votes to Grant Euripedes DeOliveira votes to Grant Theresa(Tess)Poe votes to Grant Alan Verson votes to Grant Dan Felten votes to Grant John Lutz votes to Grant Debin Bruce votes to Grant Mark Sullivan votes to Grant MOTION MADE BY. SECONDED BY: VOTE COUNT: DECISION: Theresa(Tess)Poe Dan Felten 7 Approved with Conditions MINUTES OF MEETING: Available at www.northamptonma.gov 1,Carolyn Misch,as agent to the Planning Board,certify that this is a true and accurate decision made by the Planning Board and certify that a copy of this and all plans have been riled with the Board and the City Clerk on the date shown above. I certify that a copy of this decision has been mailed to the Owner and Applicant. Notice of Appeal An appeal from the decision of the Planning Board may be made by any person aggrieved pursuant to MGL Chapt.40A,Section 17 as amended within twenty(20)days after the date of the riling of the notice of the decision with the City Clerk. The date is listed above. Such appeal may be made to the Hampshire Superior Court with a certified copy of the appeal sent to the City Clerk of the City of Northampton. GeoTMSO 2018 Des Lauriers Municipal Solutions,Inc. O 12.3 Preliminary Building Code Analvsis Building Code Abstract for use in One Stop submission Please answer the questions below, or include a building code review document which addresses each of the items. Please identify the code(s)that were used in the analysis, including what edition. 780 CMR; Massachusetts Building Code(9`h Edition) 2015 International Building Code (amended) 2015 International Energy Conservation Code(amended) If the building is new construction: MA State Building Code 780 CMR 9th Edition Is this building entirely use group R-2 or is it mixed use? Mixed use If mixed use, what other occupancies or uses? Use group B or M at level 1, and use group R-2 for all other spaces from Level 1 to 3. Construction type: Please identify type per Mass Building Code classification. Type VA Allowable height and area: Use Group B or M: 18,000 SF per story for Group B, and 14,000 SF per story for Group M. Use Group R-2: 3 Stories, 50 feet high, 12,000 SF per story. -Section 504.2 Sprinkler Height Increase+1 story,20 feet. -Section 506.2 Accessible Perimeter Increase+10,800 square feet. -Section 506.3 Sprinkler Area Modification+24,000 square feet. Total height allowed: 4 story, 70 feet. Total area allowed per floor: 46,800 square feet. Actual height and area: Use Group B or M: 12 feet, 1 story, 2,465 SF Use Group R-2: approx. 32 feet, 3 story, approx. 5059 SF per story Fire protection(sprinklers) choose one: None NFPA DSR NFPA 13 Will any variances or waivers from the building code be required? If so,please attach a description. No variances will be required 1 „ N f Louis Hasbrouck<Iasbrouck@northamptonma.gov> wtm 35 Village Hill Rd 1 message Louis Hasbrouck <Iasbrouck@northamptonma.gov> Tue, Jul 9, 2019 at 4:01 PM To: "Follett, Mark" <mfollett@westernbuilders.com> Cc: Carolyn Misch <cmisch@northamptonma.gov>, David Veleta <dveleta@northamptonma.gov>, Doug McDonald <dmcdonald@northamptonma.gov>, Kevin Ross <kross@northamptonma.gov> Mark, We received the permit application for the mixed use building at 35 Village Hill Road. If you're not involved in this project, can you pass it along and copy me?Thanks. I've attached a copy of the 2018 planning board approval and DPW comments about the project. All pre-permit and pre- construction conditions and submission requirements listed on the PB approval and DPW comments must be addressed before we can process the application. We'll also need verification of sewer and water availability from the DPW, and also a driveway permit from the DPW if required. Louis Hasbrouck Building Commissioner City of Northampton Town of Williamsburg (413) 587-1240 office (413)587-1272 fax 2 attachments PB Decision 40R.pdf 39K DPW Comments.pdf 91K �rt,� Civ of Louis Hasbrouck<Iasbrouck@northamptonma.gov> Re: External: [EXTERNAL] 35 Village Hill Rd 1 message Louis Hasbrouck<Hasbrouck@nortnamptonma.g0V> _ Tue,Aug 20,2019 at 7:39 PM To:"Follett,Mark"<mfollett@westembuilders.com> Cc:Kevin Ross<kross@northamptonma.gov>,David Veleta<dveleta@northamptonma.gov> Mark, How are things going?.I haven't seen anything lately but i could have missed it.I want to stay as far ahead of this as I can because things are really busy these days.Please let me know.Thanks. Louis Hasbrouck Building Commissioner City of Northampton Town of Williamsburg (413)587-1240 office (413)587-1272 fax On Tue,Jul 9,2019 at 4:35 PM Follett,Mark<mfollett@westembuikiers.com>wrote: Louis, I am involved in the project. Thank you for bringing that to my attention. I double checked all the permit paperwork and assumed the drawings were straight forward enough for a college grad to put together. I will check everything next time,my apologies. I will respond to the other items in a reply all email. -Mark WESTERN BUILDERS Mark Follett Mar. Project Manager Westem Builders Mobile:473.537,1683 73 Pleasant St. Office:413.437.5071 Granby,MA 01033 Email:mfollett@westernbuiklers.com From:Louis Hasbrouck[mailto:Ihasbrouck@northamptonma.gov] Sent:Tuesday,July 9,2019 4:26 PM To:Follett,Mark<mfollett@westembuilders.com> Subject:External:[EXTERNAL]35 Village Hill Rd Mark, Again,if you're not involved,pass this along.... The paper plans we got aren't in order,oriented or stapled....we'd like a set that is. Also,there doesn't seem to be a building code review,fire narratives for the sprinkler and alarm systems,and nothing on energy conservation.The residential units need preliminary HERS ratings and the commercial space needs to comply with IECC C401.2(as amended). We may have other questions when we start reviewing the plans,but we need these things to get started. If you have a project timeline,can you send that.too? Thanks. Louis Hasbrouck Building Commissioner City of Northampton Town of Williamsburg (413)587-1240 office (413)587-1272 fax ..This electronic mail message and any attachments thereto may contain confidential and/or privileged information intended only for the addressee(s)named herein.If you are not the intended recipient,you are hereby notified that the reading,disclosure,copying,distribution or use of all or any part of this communication is strictly prohibited.If you received this transmission in error,please permanently delete it and any copy or printout thereof and notify our e-mail security officer immediately either by telephone at 413-540-1401 or by sending an electronic message to support@oconnells.com. kf 1 61' P-- a '4ciX 12.3 Preliminary Buildinjj Code Analysis Building Code Abstract for use in One Stop submission Please answer the questions below, or include a building code review document which addresses each of the items. Please identify the code(s)that were used in the analysis, including what edition. 780 CMR; Massachusetts Building Code (9th Edition) 2015 International Building Code (amended) 2015 International Energy Conservation Code (amended) If the building is new construction: MA State Building Code 780 CMR 9th Edition Is this building entirely use group R-2 or is it mixed use? Mixed use If mixed use, what other occupancies or uses? Use group B or M at level 1,and use group R-2 for all other spaces from Level 1 to 3. Construction type: Please identify type per Mass Building Code classification. Type VA Allowable height and area: Use Group B or M: 18,000 SF per story for Group B, and 14,000 SF per story for Group M. Use Group R-2: 3 Stories, 50 feet high, 12,000 SF per story. -Section 504.2 Sprinkler Height Increase +1 story, 20 feet. -Section 506.2 Accessible Perimeter Increase+10,800 square feet. -Section 506.3 Sprinkler Area Modification+24,000 square feet. Total height allowed: 4 story, 70 feet. Total area allowed per floor: 46,800 square feet. Actual height and area: Use Group B or M: 12 feet, 1 story, 2,465 SF Use Group R-2: approx. 32 feet, 3 story, approx. 5059 SF per story Fire protection(sprinklers) choose one: Nene -3 D -NFPA 13 R NFPA 13 Will any variances or waivers from the building code be required? If so, please attach a description. No variances will be required Home Energy Rating Certificate Rating Date: Projected Report Registry ID: Unregistered Ekotrope ID: YLeNrG©d Index ♦ Home: Your • _ • _ is a relative i Dartmouth performance score.The lower the number, Boston, MA 02116 the more • home. • $6485 i • 53learn more,visit www.hersindex.com *Relative to an average U.S.home The Community Builders Your Home's Estimated Energy Use: This home meets or exceeds the Use[MBtul Annual Cost criteria of the following: Heating 3.2 $145 2015 International Energy Conservation Code Cooling 0.2 $9 2012 International Energy Conservation Code Hot Water 4.8 $0 Lights/Appliances 9.7 $439 Service Charges $255 Generation(e.g.Solar) 0.0 $Q Total: 17.9 $848 HERS*Index Home Feature Summary: Rating Completed by: Na•fn•rp Home Type: Apartment,inside unit Energy Rater•Karla Butterfield 150 Model: #101,Level I Studio RESNET ID:2617109 Fxietim 141, Community: N/A Homes i�0 zro Conditioned Floor Area: 615 ft' Rating Company:Steven Winter Associates,Inc. " iw Number of Bedrooms: 1 61 Washington Street,Norwalk,CT 06854 Reference 2038570200 Nome wo Primary Heating System: Air Source Heat Pump•Electric•10.3 HSPF Primary Cooling System: Air Source Heat Pump•Electric•19 SEER Rating Provider:Steven Winter Associates,Inc. , t ; 70 Primary Water Heating: Boiler•Propane•0.925 Energy Factor 61 Washington Street,Norwalk,CT 06854 "''�'• � House Tightness: 3 ACH50 2038570200 Ventilation: 40.0 CFM•20.0 Watts ♦U This Home 30 Duct Leakage to Outside: Untested a Above Grade Walls: R-29 Zero Energy r° Celling: Adiabatic,N/A Home o Window Type: U-value:0.21,SHGC:0.23 Karla Butterfield,Certified Energy Rater �mt,.esnn Foundation Walls: N/A Date:9/17/19 at 12:15 PM ekatro. EkotTopeRATER RatingThe Energy Disclosure .` i• • Rating Provider. This report does not constitute�wa"rnty or guarantee. Home Energy Rating Certificate Rating Date: Registry ID: Unregistered Projected Report Ekotrope ID: VvnanOnd HERS'9 Index _ Score: Savings Home: DartmouthYour home's HERS score is a relative 185 performanc- - .- $6 • 5 Boston, + f16 the more en - , 53 learn more,visit www.hersindex.com *Relative to an average U.S.home The Community Builders Your Home's Estimated Energy Use: This home meets or exceeds the Use(MBtul Annual Cost criteria of the following: Heating 3.2 $145 2015 International Energy Conservation Code Cooling 0.2 $9 2012 International Energy Conservation Code Hot Water 4.8 $0 Lights/Appliances 9.7 $439 Service Charges $255 Generation (e.g.Solar) 0.0 $0 Total: 17.9 $848 Home Feature Summary: Rating Completed by: wntn•.gr Home Type: Apartment,inside unit Energy RaterKarla Butterfield Ile Model: #102,Level 1 Studio SW RESNET ID:2617109 Exist ]+l• Community: N/A '30x Rating Company:Steven Winter Associates,Inc. Conditioned Floor Area: 615 ft i0 61`:Jashington Street,Norwalk,CT 06854 110 Number of Bedrooms: 1 Reference 2038570200 Home a 100 Primary Heating System: Air Source Heat Pump•Electric•10.3 HSPF Primary Cooling System: Air Source Heat Pump•Electric•19 SEER Rating Provider-Steven Winter Associates,Inc. 61 Washington Street,Norwalk,CT 06854j 70 Primary Water Heating: Boiler.Propane•0.925 Energy Factor 9 I ' 1 20385702 «r 60_ House Tightness: 3 ACH50 m, sO Ventilation: 40.0 CFM•20.0 Watts '^•"°• 40 TMS Naa• so Duct Leakage to Outside: Untested w Above Grade Walls: R-29 Zero Ener 1e Celling: Adiabatic,N/A Home • Window Type: U-Value:0.2 1,SHGC:0.23 Karla Butterfield,Certified Energy Rater 0--f1e, Foundation Walls: N/A Date:9/17/19 at 12:13 PM * RATER s - • Approved Rating Provider. This report does not constitute any warranty• Home Energy Rating Certificate Rating Date: Projected Report Registry ID: Unregistered Ekotrope ID: P210r1 M2 Savings77 HERS'9 Index Score: Annual • home'sscore is a relative 185 Dartmouth 52 performance score.The lowerthe number, Boston, 02116 the more - • home. • $809 Builder: learn more,visit www.hersindex.com *Relative to an average U.S.home The Community Builders Your Home's Estimated Energy Use: This home meets or exceeds the Use(MBtul Annual Cost criteria of the following: Heating 3.8 $171 2015 International Energy Conservation Code Cooling 0.3 $14 2012 International Energy Conservation Code Hot Water 6.0 $11 Lights/Appliances 10.2 $461 Service Charges $255 Generation (e.g.Solar) 0.0 $0 Total: 20.3 $913 HERSIndex Home Feature Summary: Rating Completed by: Mar.twgy Home Type: Apartment,end unit. Energy Rater•Karla Butterfield a� Model: #201,Level 2,1B ItESNLT If):2617109 Community: NIA "G+nPti „ Rating Company:Steven Winter Associates,Inc. Conditioned Floor Area: 758 ft2 Number of Bedrooms: 1 61 Washington Street,Norwalk,CT 06854 Reterenm � 2038570200 oma loo Primary Heating System: Air Source Heat Pump•Electric•10.3 HSPF e Primary Cooling System: Air Source Heat Pump•Electric•19 SEER Rating Provider-Steven Winter Associates,Inc. , Primary Water Heating: Boiler.Propane•0.925 Energy Factor 61 Washington Street,Norwalk,CT 06854 w, r,m 2038570200 "`�" ' '7•`'' House Tightness: 3 ACH50 $°—ift Ventilation: 40.0 CFM•20.0 Watts 30 Duct Leakage to Outside: Untested w Above Grade Walls: R-29 !ero Energy 1° Ceiling: Adiabatic,N/A """'e • Window Type: U-Value:0.21,SHGC:0.23 Karla Butterfield,Certified Energy Rater •. Foundation Walls: N/A Date:9117119 at 12:15 PM ek! ! ! EkotropeRATER • Disclosurefor Approved• + This report does not constituteanty or guarantee. Home Energy Rating Certificate Rating Date: Projected Report Registry ID: Unregistered Ekotrope ID: x25aezO2 IndexHome:ngs Your home's HERS score is a relative 185 Dartmouth performance score.The lower the number, $948 Boston, MA 02116the more energy efficient the home.To 52learn more, • • -to an average • - The Community Builders Your Home's Estimated Energy Use: This home meets or exceeds the Use(MBtu] Annual Cost criteria of the following: Heating 4.0 $181 2015 International Energy Conservation Code Cooling 0.3 $14 2012 International Energy Conservation Code Hot Water 8.3 $11 Lights/Appliances 11.8 $533 Service Charges $255 Generation(e.g.Solar) 0.0 $0 Total: 24.4 $994 r Home Feature Summary: Rating Completed by: w•r.!••r�y Home Type: Apartment:,inside unit Energy Rater:Karla Butterfield aso Model: #202,Level 2,2-Br RESNET ID-.2617109 Exi '°° Community: N/A ibz Rating Company:Steven Winter Associates,Inc. in ft Conditioned Floor Area: 962 xw Number of Bedrooms: 2 61"�dashingion Street,Norwalk,CT 06854 Reference 2038570200 Home wo Primary Heating System: Air Source Heat Pump•Electric•10.3 HSPF . Primary Cooling System: Air Source Heat Pump•Electric•19 SEER Rating Provider.Steven Winter Associates,Inc. f so TO Primary'Water Heating: Boiler.Propane•0.925 Energy Factor 61 Washington Street,Norwalk,CT06854 2038570200 60 House Tightness: 3 ACH50 so �� Ventilation: 40.0 CFM•20.0 Watts '`°""'"' taThis Home m Duct Leakage to Outside: Untested » Above Grade Walls: R-29 zeroE to Ceiling: Adiabatic,N/A 0 Window Type: U-Value:0.21,SHGC:0.23 rt, Karla Butterfield,Certified Energy Rater Foundation Walls: N/A Date:9/17/19 at 12:16 PM dwtro _ Ekotrol-.)p •Y tic Tbe Energy RatingDisclosurfe forApproved Ratincl Provider. This report does not constituteany warranty or Home Energy Rating Certificate Rating Date: Registry ID: Unregistered Projected Report Ekotrope ID: kvyeroav HERS" IndexScore: Savings 185 r • - a - is a relative # . • 52 performance score. • - - number, Boston, j s the more energy efficient the home.To $ 776 Builder: learn more, visit www.hersindex.com *Relative to an average U.S.home The Community Builders Your Home's Estimated Energy Use: This home meets or exceeds the Use[MBtu] Annual Cost criteria of the following: Heating 3.2 $144 2015 International Energy Conservation Code Cooling 0.3 $12 2012 International Energy Conservation Code Hot Water 6.0 $11 Lights/Appliances 10.2 $460 Service Charges $255 Generation(e.g.Solar) 0.0 $0 Total: 19.7 $883 HERSIndex Home Feature Summary: Rating Completed by: Mor•Cn•reY Home Type: Apartment,end unit. Energy Rater•Karia Butterfield Madel: 41203,Level 2,1-Br RESNEf ID:2617109 rx ' Community: N/A Rating Company:Steven Winter Associates,Inc. Conditioned Floor Area: 751 ftl 61 V,11ashington Street,Norwalk,CT 06854 Number of Bedrooms 1 2038570200 f:erere�cc I+pm� 10° Primary Heating System: Air Source Heat Pump•Electric•10.3 HSPF Primary Cooling System: Air Source Heat Pump•Electric•19 SEER Rating Provider:Steven Winter Associates,Inc. ,, Primary Water Heating: Boiler.Propane•0.925 Energy Factor 61 Washington Street,Norwalk CT 06854 V ww At — House Tightness: 3 ACHSO 2038570200 ?i~ Ventilation: 40.0 CFM.20.0 Watts ' iMs tiara! Duct Leakage to Outside: Untested za Above Grade Walls: R-29 1.Enrr Ceiling: Adiabatic,N/A P° 4 Window Type: U-Value:0.2 1,SHGC:0.23 oma�r�ti.tt �"' Foundation Walls: N/A Karla Butterfield,Certified Energy Rater Date:9117119 at 12:17 PM RATEREkot rope The Energy Rating -for this hi:wrne is available from the Approved Rating Provider. Home Energy Rating Certificate Rating Date: Registry ID: Unregistered Projected Report EkotropeID: DLzgEbR2 Index Annual DartmouthYour home's HERS score is a relative 185 Street 52leaperformance score.The lower the number, Boston, 02116 the more energy efficient the home.To $ 792 Builder: rn more, • • to an average U.S.homeBuilders Your Home's Estimated Energy Use: This home meets or exceeds the Use[MBtu] Annual Cost criteria of the following: Heating 3.9 $176 2015 International Energy Conservation Code Cooling 0.2 $11 2012 International Energy Conservation Code Hot Water 6.0 $11 Lights/Appliances 10.2 $461 Service Charges $255 Generation(e.g.Solar) 0.0 $0 Total: 20.4 $914 HERS Index Home Feature Summary: Rating Completed by: �. hog"rn•r Horne Tyne: Apartrnent,end unit Energy Rater:Karia Butterfield Model: tt204,Level 2,1-Br RESNEi I13:2617109 " Y Community: N/A Conditioned Floor Area: 758 ftp Rating Company:Steven Winter Associates,Inc. 61 Washington Street,Norwalk,CT 06854 -io Number of Bedrooms: i loo 20385702{)O m� Primary Heating System: Air Source Heat Pump•Electric•10.3 HSPF Primary Cooling System: Air Source Heat Purnp Electric•19 SEER Rating Provider:Steven Winter Associates,Inc. Primary Water Heating: Boiler.Propane•0.925 Energy Factor 61 Washington Street,Norwalk,CT 06854 i ZI w House Tightness: 3 ACHSO 2038S70200 +s,�—J& � Ventilation: 40.0 CFM•20.0 Watts so This dome Duct Leakage to Outside: Untested :o Above Grade Walls: R-29 Zero me Er Ceiling: Adiabatic,N/A Mo0 Window Type: U-Value:0.21,SHGC:0.23 Karla Butterfield,Certified Energy Rater Foundation Walls: N/A Date:9/17/19 at 12:18 PM • • • RATER The Eriprq Rating Disclosure for •• • ° • •- Home Energy Rating Certificate Rating Date: Registry ID: Unregistered Projected Report EkotropeID: BdNkyl8v HERS's Index Score: Annual home'sYour - 185 Dartmouth performance score.The lower the number,51 $9613 :o • 1 • the more energy efficient the - Builder:• • s . . • Your Home's Estimated Energy Use: This home meets or exceeds the Use[MBtul Annual Cost criteria of the following: Heating 3,5 $157 2015 International Energy Conservation Code Cooling 0.4 $17 2012 International Energy Conservation Code Hot Water 8.3 $11 Lights/Appliances 11.8 $533 Service Charges $255 Generation(e.g.Solar) 0.0 $0 Total: 24.0 $974 Home Feature Summary: ' � Rating Completed by: Moret—ly Home Type: Apartment,inside unit Energy Rater:Karla Butterfield ;P3 Model: #205,Level 2,2-BrRLSNE I ID:2617109 roH R1P5''PS oma Community: N/A -'�� ty< Conditioned Floor Area: 962 ft2 Rating Company:Steven Winter Associates,Inc. 61 Washington Street,Norwalk,CT 06854 Number of Bedrooms: 2 2038570200 Reference 1p0 Primary Heating System: Air Source Heat Pump•Electric 103 HSPF Primary Cooling System: Air Source Heat Pump a Electric.•19 SEER Rating Provider:Steven Winter Associates,Inc, Primary Water Heating: Boiler•Propane•0-925 Energy Factor fit Washington Street,Norwalk,CT 06854 House Tightness: 3 ACH50 2038570200 Ventilation: 40.0 CFM•20.0 Watts h TMstrome Duct Leakage to Outside: Untested Above Grade Walls: R-29 zeroenergyto Ceiling: Adiabatic,N/A Hr.,4ne Window Type: U-Value:0.21,SHGC:0.23 Karla Butterfield,Certified Energy Rater ., Foundation Walls: NIA Date:9/17/19 at 12:22 PM ! Ll ! constituteThe Energy Rating Disclosure for this home is available from the Approved Rating Provider. This report does not or Home Energy Rating Certificate Rating Date: Registry(D: Unregistered Projected Report EkotropeID: MvDVjZOL Index Score: AnnualHome:ngs 185 Dartmouth Stre- Your score is aperformance score.The lower the number, Boston, • • the more energy efficient the home.To $877 Builder: 51 learn more,visit www.hersindex.com *Relative to an average U.S.home The Community Builders Your Home's Estimated Energy Use: This home meets or exceeds the Use[MBtu] Annual Cost criteria of the following: Heating 4.5 $203 2015 International Energy Conservation Code Cooling 0.4 $17 2012 International Energy Conservation Code Hot Water 6.0 $11 Lights/Appliances 10.2 $461 Service Charges $255 Generation (e.g.Solar) 0.0 $0 Total: 21.1 $947 HERSIndex Home Feature Summary: Rating Completed by: Mwitmr`q Horne Type: Apartment,encs unit. Energy Rater:Karla Butterfield rso Model: #301,Level 3,1-Br RESNEf 1D:2617109 10 Community: NIA 130 Rating Company:Steven Winter Associates,Inc. Conditioned Floor Area: 758 ftp 120 61 Washington Street,Norwalk,CT 06854 Number of Bedrooms: 1 2038570200 roo Primary Heating System: Air Source Heat Pump•Electric•10.3 HSPF � 4 Primary Cooling System: Air Source Heat Pump•Electric•19 SEER Rating Provider:Steven Winter Associates,Inc. �'µ t ' 61 Washington Street,Norwalk,CT 06854 Primary Water Heating: Boiler.Propane•0.925 Energy Factor 9 i = Mwtw r `E _ 2038570200 House Tightness: 3 ACH50 _e a Ventilation: 40.0 CFM•20.0 Watts This How Duct Leakage to Outside: Untested Above Grade Walls: R-29 Zero Ener w Ceiling: Vaulted Roof R-52 Home 0 Window Type: U-Value:0.2 1,SHGC:0.23 �„r.,a Karla Butterfield,Certified Energy Rater t.,301%wl Foundation Walls: NIA Date:9/17119 at 3:56 PM • • • '" Ekot rope RATER constituteThe Energy Rating DixJosure for this horne is available from the Approved Rating Provider. This report does not or Home Energy Rating Certificate Rating Date: Projected Report Registry ID: Unregistered Ekotrope ID: ILXayEOd • C Index _ Home: iDartmouth • home's • i f • • performancescore. • number, the more • home. • $ 1 ,047 Builder: 52learn more, • • to an average U.S.homeBuilders Your Home's Estimated Energy Use: This home meets or exceeds the Use(NlBtu] Annual Cost criteria of the following: Heating 5.0 $226 2015 International Energy Conservation Code Cooling 0.4 $18 2012 International Energy Conservation Code Hot Water 8,3 $11 Lights/Appliances 11.8 $533 Service Charges $255 Generation(e.g.Solar) 0.0 $0 Total: 25.5 $1,044 HERSIndex Home Feature Summary: Rating Completed by: -411111- Mortine y Home Type: Apartment,inside unit Energy Rater•Karla Butterfield xso Model: 9302,Level 3,2-BR RESNET 0:2617109 Community: NAA HOMPConditioned Floor Area: 9fi2 ft2 Rating Company:Steven Winter Associates,Inc. Number of Bedrooms: 2 61 Washington Street,Norwalk,CT 06854 2e re rent c 2038570200 Home loo Primary Heating System: Air Source Heat Pump.Electric-10.3 HSPF Primary Cooling System: Air Source Heat Pump•Electric-19 SEER Rating ProvidenSt:e.ven Winter Associates,Inc. Primary Water Heating: Boiler•Propane•0.925 Energy Factor 61 Washington Street,Norwalk,CT 06854 2038570200 ' "•�w:': =t House Tightness: 3 ACH50 �� Ventilation: 40.0 CFM•20.0 Watts This Han e Duct Leakage to Outside: Untested Above Grade Walls: R-29 Zero F—rgy Ceiling: Vaulted Roof R-52 Home 0Window Type: U-Value:0.21,SHGC:0.23 Karla Butterfield,Certified Energy Rater oaoa,.w•+ Foundation Walls: N/A Date:9/17/19 at 3:56 PM ! ! ! Die Ener(y • Disclosure for •• d Ratinc Provider, This report does not constituteor Home Energy Rating Certificate Rating Date: Registry ID: Unregistered Projected Report Ekotrope ID: bL7R4la2 AnnualHERS' Index Score: DartmouthYour home's HERS score is a relative 185 performance score.The lower the number, 854 Boston, 02116 the more energy efficient the home.To $ Builder: learn more,visit 51 www.hersindex.com - .an average U.S.home TheCommunityBuilders Your Home's Estimated Energy Use: This home meets or exceeds the Use[MBtu] Annual Cast criteria of the following: Heating 4.0 $180 2015 International Energy Conservation Code Cooling 0.3 $15 2012 International Energy Conservation Code Hot Water 6.0 $11 Lights/Appliances 10.2 $460 Service Charges $255 Generation (e.g.Solar) 0.0 $0 Total: 20.5 $921 Home Feature Summary: Rating Completed by: Merctwiry Horne Type: Apartment,inside unit Energy Rater:Karla Butterfield ISO Model: #303,Level 3,1 Br 11E5NEi ID:2C>17104 tx"SL'oR 'i0 Community: NIA rt°mey 130120 Conditioned Floor Area: 751 ft2 Rating Company:Steven Winter Associates,Inc. o Number of Bedrooms: 1 61 Washington Street,Norwalk,CT 06854 Reference 2038570200 Hemp 104 Primary Heating System: Air Source Heat Pump•Electric•10.3 HSPF � w ?G Primary Cooling System: Air Source Heat Pump•Electric•19 SEER Rating Provider-Steven Winter Associates,Inc. _• ao Primary Water Heating: Boiler•Propane•0.925 Energy Factor 61 Washington Street,Norwalk,CT 06854 2038S70200 '_ House Tightness: 3 ACH50 �D Ventilation: 40.0 CFM•20.0 Watts A° Tnis r+orne 9 Duct Leakage to Outside: Untested so ` >= Above Grade Walls: R-29 zero fuer y �� Ceiling: Vaulted Roof,R-52 t+nrti8 1Q Window Type: U-Value:0.2 1,SHGG 0.23 Karla Butterfield,Certified Energy Rater Foundation Walls: NIA Date:9117!79 at 3:55 PM This report does not constituteor Home Energy Rating Certificate Rating Date: Projected Report Registry ID: Unregistered Ekotrope ID: KvpQrl62 HERS' Index Score: Annual Savings Home: 185 Dartmouth Your home's HERS score is a - Boston, • performance score.The lower the number, the more ♦ home. a $871 « • 2 learn more, • • to an average • Communityi Your Home's Estimated Energy Use: This home meets or exceeds the Use WSW Annual Cost criteria of the following: Heating 4.7 $213 2015 International Energy Conservation Code Cooling 0.3 $13 20112 International Energy Conservation Code Hot Water 6.0 $11 Lights/Appliances 10.2 $461 Service Charges $255 Generation(e.g.Solar) 0.0 $0 Total: 21.3 $953 Home Feature Summary: Rating Completed by: ►t•n[iwrp Horne Type: Apartment,end unit Energy Rater•Karla Butterfield ra Model: #304,Level 3,1 Br IIESNE 10:2617109 Existing � Community: N/A Homes xr Rating C=ompany:Steven Winter Associates,Inc. xa Conditioned Floor Area: 758 ftp r® Number of bedrooms: t 61 Washington Street,Norwalk CT 06€i54 Refemme 2038570200 Home µ, Primary Heating System: Air Source Heat Pump-Electric-10.3 HSPF Primary Cooling System: Air Source Heat Pump•Electric•19 SEERRating Provider:Sievert Winter Associates,Inc. zr„ °° fit Washington Street,Norwalk,CT O6854 "`` J.r Primary Water Heating: Boiler•Propane•0.925 Energy Factor gf ( w 203857.0200 "'*�`• t`'' e� House Tightness: 3 ACH503 #° Ventilation: 40.0 CFM•20.0 Watts 6C This Home w Duct Leakage to Outside: Untested o Above Grade Wails: R-29 Zero Ener Ceiling: Vaulted Roof,R-52 H° Q 1 Window Type: U-Value:0.21,SHGC:0.23 Karla Butterfield,Certified Energy Rater `+"E�"" Foundation Walls: N/A Date:9117/19 at 3:54 PM Ekotropp RATER Home Energy Rating Certificate Rating Date: Projected Report Registry ID: Unregistered Ekotrope ID: yvPXDDVv Index Home: Dartmouth185 Your home's HERS score is a relative performance score.The - $ 1 , 12 , Boston, ' 02116 - • 4 9 learn more visit • • -to . .e U.S.home The CommunityBuilders Your Home's Estimated Energy Use: This home meets or exceeds the Use IMBtuj Annual Cost criteria of the following: Heating 5.0 $225 2015 International Energy Conservation Code Cooling 0.5 $21 2012 International Energy Conservation Code Hot Water 6.7 $0 Lights/Appliances 11.7 $528 Service Charges $255 Generation(e.g.Solar) 0.0 $0 Total: 23.8 $1,029 Home Feature Summary: Rating Completed by: Merebow Home Type: Apartment,inside unit Energy RaterKarla Butterfield a5o Model: #305,Level 3,2-BR SE RESNET ID:2617109 Exisriri.o Community: N/A 130 Rating Company:Steven Winter Associates,Inc. 320 Conditioned Floor Area: 938 ftZ Ito Number of Bedrooms: 2 61 Washington Street,Norwalk,CT 06854 Reference 2038570200 Home WO Primary Heating System: Air Source Heat Pump•Electric•10.3 HSPF Primary Cooling System: Air Source Heat Pump•Electric•19 SEER Rating Provider:Sleven Winter Associates,Inc. 70 Primary Water Heating: Boiler.Propane.0.925 Energy Factor 61 Washington Stmt,Norwalk CT 06854 2038570200 House Tightness 3 ACHSO so Ventilation: 40.0 CFM•20.0 Watts Horne h' so TMs Har Duct Leakage to Outside: Untested xo 30 Above Grade Walls: R-29 Zero Ener 1° Ceiling: Vaulted Roof,R-52 Home 0 Window Type: U-Value:0.21,SHGC:0.23 Karla Butterfield,Certified Energy Rater 4M=eu ee+ Foundation Walls: N/A Date:9!17119 at 3:53 PM constitutewtr Ener(.y Rating Disclosure for this home is available from the Approved Rating Provider. This report does riot or Home Energy Rating Certificate Rating Date: Registry ID: Unregistered Projected Report Ekotrope ID: VvnanOnd HERS' Index Score: ur home's HERS score is a relative 185 Dartmouth Street performance score.The lower the number, • Boston, the more energy efficient the home. To $6115• Builder lea 5 3 Yorn more, visit www.hersindex.com - to . .- U.S.home The CommunityBuilders Your • - Your Home's Estimated Energy Use: This home meets or exceeds the Use(MBtul Annual Cost criteria of the following: Heating 3.2 $145 2015 International Energy Conservation Code N Cooling 0.2 $9 2012 International Energy Conservation Code Hot Water 4.8 $0 Lights/Appliances 9.7 $439 Service Charges $255 Generation (e.g.Solar) 0.0 $0 Total: 17.9 $848 HERSInclex Home Feature Summary: Rating Completed by: m "Jift, ftnumn Home Type: Apartment,inside unit Energy Rater:Karla Butterfield I" Model: #102,Level 1 Studio SW Exisring140 RESNET ID 2617109 n Homes Community: N/A " O Conditioned Floor Area: 615 ftz Rating Compony:Steven Winter Associates,Inc f0 61 Washington Street,Norwalk,CT 06854 uo Number of Bedrooms: 1 Reference 100 Primary Heating System: Air Source Heat Pump•Electric•103 HSPF 2038570200 Home q0 Primary Cooling System: Air Source Heat Pump.Electric•19 SEER Rating Providec5teven Winter Associates,Inc °0 70 Primary Water Heating: Boiler•Propane•0.925 Energy Factor 61 Washington Street,Norwalk,CT 06854 ` 60_ House Tightness: 3 ACH50 2038570200 t S0 Ventilation: 40.0 CFM•20.0 Watts •o TM'Home Duct Leakage to Outside: Untested 30 m Above Grade Walls: R-29 Zero En 10 Ceiling: Adiabatic,N/A ►some o Window Type: U Value:0.21,SHGC:0.23 ,,.. Karla Butterfield,Certified Energy Rater om,nv.. -4w Foundation Walls: N/A Digitally signed:7/11/19 at 10:27 AM Home Energy Rating Certificate Rating Date: Projected Report Registry ID: Unregistered Ekotrope ID: x25aezO2 HERS' Index Score: Annual Savings Home: Your home's HERS score is a relative 185 Dartmouth Street performance score.The lower , Boston, MA 02116 the more 52 learn $ 948energy - - Builder: more, . .m *Relative to . .- U.S. home • Builders Your Home's Estimated Energy Use: This home meets or exceeds the Use[MBtul Annual Cost criteria of the following: Heating 4.0 $181 2015 International Energy Conservation Code Cooling 0.3 $14 2012 International Energy Conservation Code Hot Water 8.3 $11 Lights/Appliances 11.8 $533 Service Charges $255 Generation (e.g.Solar) 0.0 $0 Total: 24.4 $994 HERSIndex Home Feature Summary: Rating Completed by: 04weO " Home Type: Apartment,inside unit Energy Rater:Karla Butterfield 1w Model: #202,Level 2,2-BR NW RESNET ID-2617109 1=9 114 Community: N/A 170 Conditioned Floor Area: 962 ftZ Rating Company:Steven Winter Associates,Inc 120 61 Washington Street,Norwalk,CT 06854 u° Number of Bedrooms: 2 Reference 100 Primary Heating System: Air Source Heat Pump•Electric•103 HSPF 2038570200 Home• 90 Primary Cooling System: Air Source Heat Pump•Electric•19 SEER Rating Provider:Steven Winter Associates,Incso 3. 70 Primary Water Heating: Boiler•Propane•0.925 Energy Factor 61 Washington Street,Norwalk,CT 06854 60 House Tightness: 3 ACH50 2038570200 - - S0 Ventilation: 40.0 CFM•20.0 Watts 40 7M%Hmne Duct Leakage to Outside: Untested w m Above Grade Walls: R-29 Zero En 10 Ceiling: Adiabatic,N/A Window Type: U-Value:0.2 1,SHGC.0.23 .m,,.�°.. �' `""""p' Foundation Walls: N/A Karla Butterfield,Certified Energy Rater Digitally signed:7/11/19 at 10:29 AM elwtro The Home Energy • StandardD • •r this house is available fromthe g provider. Home Energy Rating Certificate Rating Date: Registry ID: Unregistered Projected Report Ekotrope ID: bL7KRJeL HERSO Dartmouth Index Score: Annual Savings Home: 43yarour home's HERS 185 performancescore. lowernumer, 02116 the more energy efficient le n more, visit www.hersindex.com *Relative to an average U.S. home The Community Builders Your Home's Estimated Energy Use: This home meets or exceeds the Use[MBtu] Annual Cost criteria of the following: Heating 3.8 $170 2015 International Energy Conservation Code Cooling 0.4 $18 2012 International Energy Conservation Code Hot Water 6.7 $0 Lights/Appliances 11.7 $528 Service Charges $255 Generation (e.g.Solar) 2.2 -$99 Total: 22.6 $872 HERSIndex Home Feature Summary: Rating Completed by: N•nEn.rp Home Type: Apartment,inside unit Energy Rater:Karla Butterfield lso Model: #305,Level 3,2-BR SE RESNET ID-2617109 Existingl100 Community: N/A 110 Conditioned Floor Area: 938 ft2 Rating Company:Steven Winter Associates,Inc 120 61 Washington Street,Norwalk,CT 06854 io Number of Bedrooms: 2 Reference 100 Primary Heating System: Air Source Heat Pump•Electric•103 HSPF 2038570200 Nome vo Primary Cooling System: Air Source Heat Pump•Electric•19 SEER Rating Provider.Steven Winter Associates,Inc w Primary Water Heating: Boiler•Propane•0.925 Energy Factor 61 Washington Street,Norwalk,CT 06854 •o House Tightness: 3 ACH50 2038570200 so Ventilation: 40.0 CFM•20.0 Watts 40 t w TAis"Me Duct Leakage to Outside: Untested • 20 Above Grade Walls: R-29 Zero En 10 Ceiling: Adiabatic,N/A HO1Te 0 Window Type: U-Value:0.21,SHGC:0.23 ,.,,•,,,a Karla Butterfield,Certified Energy Rater .,,,,•„■, Foundation Walls: N/A Digitally signed:7/11/19 at 1032 AM BI IR aumviNG ENGiNb'.6KlNG RrsovotcFs. INC. Commonwealth of Massachusetts State Building Code 780 CMR, 9th Edition Chapter 9 Fire Protection Systems 780 CMR — 903.1.1 Narrative Report Village Hill, 35 Village Hill Road — Northampton, MA BER Project Number: 17219 July 10, 2019 Prepared By: Chris Uniacke—Fire Protection Department Steven R. Berthelette, LC—Electrical Department 66 Main Street I North Easton,Massachusetts 02356 1 T 508.230.0260 1 F 508.230.0265 1 BER@BER-engineering.com 780 CMR 903.1.1 Narrative Report Village Hill,35 Village Hill Road—Northampton,MA/BER#17219 July 10,2019 Page 1 780 CMR 903.1.1 — Narrative Report (La) BASIS—METHODOLOGY OF DESIGN Section 1 —Building Description A) Building"Use" Group: B,M and R-2. B) Total Area of Building: 7,524 square feet. C) Building Height: 43'-4". D) Number of Floors Above Grade: Three (3). E) Number of Floors Below Grade: Zero (0). F) Square Footage per Floor: First floor=2,465 sq. ft., Second and Third floors=2,530 square feet each. G) Type(s)of Occupancies (Hazards)within the Building: Residential, Retail, Business and Storage. H) Type(s)of Construction: VA (5A). I) Hazardous Material Usage and Storage:N/A. J) High Storage (over 12 feet) of Commodities within Building:N/A. K) Site Access Arrangement for Emergency Response Vehicles: Truck access via Village Hill Road and parking lot at rear of building.A fire hydrant is located at the front of the building on Village Hill Road. Fire Department connection is located at the sprinkler room located at the rear of the building. Note: All Section 1 input is in accordance with the architectural design. BER is not responsible for the classification of the structure or the associated architectural design. Section 2—Applicable Laws,Regulations and Standards A) 780 CMR Massachusetts State Building Code—9th Edition. B) Applicable NFPA Standards and Edition used for design of each specific Fire Protection System (unless otherwise indicated, shall be the latest codes and standards accepted by The Commonwealth of Massachusetts). 1. NFPA 1 —"Uniform Fire Code" 2. NFPA 10 —"Portable Fire Extinguishers" 3. NFPA 13 —"Installation of Sprinkler Systems" 4. NFPA 14 —"Installation of Standpipe and Hose Systems" 5. NFPA 24 —"Private Water Service Mains" 6. NFPA 25 —"Inspection and Testing of Water Based Fire Protection Systems" 7. NFPA 30 —"Flammable and Combustible Liquids Code" 8. NFPA 54 —"National Fuel Gas Code" 9. NFPA 70 —"National Electrical Code" 10.NFPA 72 —"National Fire Alarm Code" 11.NFPA 90A —"Installation of Air Conditioning and Ventilation Systems" 12.NFPA 101 —"Life Safety Code" 66 Main Street I North Easton,Massachusetts 02356 1 T 508.230.0260 1 F 508.230.0265 1 BER@BER-engineering.com PA2017_All Projects\17219 Village Hill-Northampton MA\Correspondence\Narrative Report 35 Village Hill Road(FP FA Systems)07.10.19.docx 780 CMR 903.1.1 Narrative Report Village Hill,35 Village Hill Road—Northampton,MA/BER#17219 July 10,2019 Page 3 1. Apartments and other areas protected by residential sprinkler heads shall meet the requirements of NFPA 13, residential design. The design density shall be a minimum of 0.10 GPM per square feet and meet the Manufacturer's minimum listed design criteria for the specific sprinkler head specified. The design area shall include the hydraulically most remote four(4)contiguous sprinkler heads regardless of the fire compartment boundaries. 2. Offices, open areas, lobbies,public toilet rooms, and similar occupancies shall meet the requirements of Light Hazard Occupancy with a density of 0.10 GPM per square feet over the hydraulically most remote 1,500 square feet. 3. Service/utility areas and similar occupancies shall meet the requirements of Ordinary Hazard Group 1 Occupancy with a density of 0.15 GPM per square feet over the hydraulically most remote 1,500 square feet. 4. General storage rooms,multi-tenant residential storage rooms, and similar occupancies shall meet the requirements of Ordinary Hazard Group 2 Occupancy with a density of 0.20 GPM per square feet over the hydraulically most remote 1,500 square feet. C) Standpipe risers shall be sized to provide 100 psi while flowing at 250 GPM at the two (2) most remote outlets on the most remote standpipe riser. An additional 250 GPM shall be added at the most remote outlet of each additional riser. The calculation shall be based on the fire department pumping fire department connection at 150 PSI static, 140 PSI residual at the required flow. FIRE ALARM A) An addressable Fire Alarm System shall be provided for initiation device monitoring and evacuation signal initiation. The fire alarm control panel shall obtain backup power via internal batteries with 60 hours of capacity. 1. Initiation Devices shall include: a. Manual pull stations shall be provided at each egress and upper floor. b. Sprinkler flow and tamper switches. c. Smoke and heat detectors located in accordance with NFPA requirements. Detectors shall be analog addressable to provide means of alarm verification and define maintenance cycles. d. Analog addressable duct smoke detectors located in accordance with NFPA requirements. Provide addressable control modules for interface with the HVAC equipment for automated shutdown. e. The building shall be provided with 100%smoke detector coverage for the egress paths (corridors and stairwells). 2. Alarm notification shall be via horn/strobe units in compliance with ADA requirements for strobe illumination levels. Strobe shall be synchronized. 66 Main Street I North Easton,Massachusetts 02356 1 T 508.230.0260 1 F 508.230.0265 1 BER@BER-engineering.com P12017_AII Projects\17219 Village Hill-Northampton MA\Correspondence\Narrative Report 35 Village Hill Road(FP FA Systems)07.10.19.docx 780 CMR 903.1.1 Narrative Report Village Hill,35 Village Hill Road—Northampton,MA/BER#17219 July 10,2019 Page 2 C) Massachusetts General Law Chapter 148 "Fire Prevention" D) 521 CMR"Architectural Access Board" E) 527 CMR"Board of Fire Prevention Regulations" including 527 CMR Chapter 12 "MA Electric Code". F) ADA (Americans with Disabilities Act) G) MWRA H) Federal Laws I) OSHA J) UL 555S—Smoke Dampers and Combination Fire Smoke Dampers K) ASTM E 84—Test Methods for Surface Burning Characteristics of Building Materials L) ASTM E 119—Test Methods for Fire Tests of Building Construction and Materials Section 3 —Design Responsibility for Fire Protection Systems A) Building Engineering Resources (BER), Professional Engineers,has fully engineered, designed(complete layout and calculations) and specified the Fire Protection Systems to be installed. BER will review the Installing Contractor's shop drawings. The PE is considered the engineer of record and certifies system installation for code compliance at completion. B) The Northampton Fire Department shall review and approve final shop drawings before installation for code compliance at completion. Section 4—Fire Protection Systems To Be Installed FIRE SUPPRESSION A) The Fire Suppression System water service shall be fed from the existing city main.A new 6" service main shall be brought into the sprinkler room. There will be one main 6" double check valve assembly at the fire service entrance into the building. The latest flow test data available is 89 PSI static with 65 PSI residual while flowing 1,350 GPM. 1. Fire Department inlet connection shall be provided at the rear of the building outside sprinkler room for boosting pressure to the entire system. Fire department connection is located within 100 feet of a hydrant and is equipped with check valves and ball drips.Nameplate on the fire department connection shall be labeled"AUTO SPKLR STANDPIPE". B) Sprinkler Systems shall provide 100%coverage and in general be as follows: 66 Main Street North Easton,Massachusetts 02356 T 508.230.0260 1 F 508.230.0265 BER@BER-engineering.com PA2017_All Projects\17219 Village Hill-Northampton MA\Correspondence\Natrative Report 35 Village Hill Road(FP FA systems)07.10.19.docx 780 CMR 903.1.1 Narrative Report Village Hill,35 Village Hill Road—Northampton,MA/BER#17219 July 10,2019 Page 5 B) Wet Pipe Standpipe System: Fire Department manually opens a fire department hose valve(s). Water from the water filled pipe is discharged immediately from the fire department hose valve(s). The fire department may connect to the fire department connection(s) and pump additional water to supplement the system. Sprinkler System water flow alarms activate upon system flow and indicate to the fire alarm control panel an alarm condition. The fire department hose valve(s)continue to flow water until manually shut off. FIRE ALARM A) The operation of a manual station or activation of any automatic alarm initiating device (smoke, heat or water flow) shall automatically: 1. Sound all audible devices throughout the building in a synchronized code 3 temporal pattern. 2. Flash all visual signals throughout the building in a synchronized fashion. 3. Flash an alarm LED and sound an audible signal at the fire alarm control panel and annunciator. Upon Acknowledge,the alarm LED shall light steadily and the audible shall silence. Subsequent alarms shall re-initiate this sequence. 4. Initiate the transmission of an alarm to the Municipal Fire Station and monitoring company via the master box and auto dialer. 5. Visually indicate the alarm initiating device type and location via the LCD display located at the fire alarm control panel. 6. Visually annunciate on all system annunciators the initiating device type and location. 7. Activate the outside weatherproof beacon. 8. Record the alarm in the event history log, and print a record of the alarm on the system printer where applicable. 9. Activate prioritized output relays to shut down affected supply and return air handlers, and initiate stairwell and elevator pressurization or smoke exhaust fans as required. 10. Operate prioritized outputs to release all magnetically locked doors throughout the building. B) The operation of a sprinkler tamper or a duct smoke detector shall automatically: 1. Flash a supervisory LED and sound an audible signal at the fire alarm control panel. Upon Acknowledge,the supervisory LED shall light steadily and the audible shall silence. Subsequent supervisory shall re-initiate this sequence. 2. Visually indicate the supervisory initiating device type and location via the LCD display located at the fire alarm control panel. 66 Main Street I North Easton,Massachusetts 02356 1 T 508.230.0260 F 508.230.0265 1 BER@BER-engineering.com PA2017—AII Projects\17219 Village Hill-Northampton MA\Correspondence\Narrative Report 35 Village Hill Road(FP FA Systems)07.10.19.docx 780 CMR 903.1.1 Narrative Report Village Hill,35 Village Hill Road—Northampton,MA/BER#17219 July 10,2019 Page 4 3. Wiring methods for all fire alarm initiation and notification circuits shall be Type MC where concealed and EMT where exposed interior. MC shall be listed for fire alarm service and identified as fire alarm service by red spray and painted couplings and junction box covers. 4. The Fire Alarm System shall be interconnected with the Lighting Control System. Lighting shall be brought to full illumination upon an alarm signal. B) Fire department notification shall be via the master box and digital dialer. A signal shall be forwarded to Owner's monitoring company for both system trouble and alarm. A signal shall be forwarded to fire department for system alarms. Section 5 —Features Used in the Design Methodology A) Building occupant notification is automatic via horn/strobe units installed in accordance with NFPA and ADA requirements. All evacuation zones shall be simultaneously notified. B) Future fire alarm testing, maintenance of systems and documentation shall be per NFPA-72. The Electrical Contractor shall provide a one-year maintenance contract on the Fire Alarm System for the duration of the warranty period. The Contractor shall provide code mandated testing and documentation on a quarterly basis as required by written regulation in NFPA-72. Section 6—Special Consideration and Description A) This project does not deviate from the prescriptive code requirements included in the referenced Laws,Regulations or Standards. (1.b) SEQL?F.NCE OF OPERATION Section 1 FIRE SUPPRESSION A) Wet Pipe Sprinkler System: Heat produced from a fire melts the fusible link or glass bulb on a single sprinkler head or group of sprinkler heads causing the sprinkler(s)to open. 1. Fusible links are rated as follows: a. Quick Response Heads: 135°F b. Standard Response Heads: 165°F c. Intermediate Response Heads: 212°F Water from the water filled pipe is discharged immediately from the sprinkler head(s)to control the fire. The fire department may connect to the fire department connection(s)and pump additional water to supplement the system. Sprinkler System water flow alarms activate upon system flow and indicate to the fire alarm control panel an alarm condition. The sprinkler(s) continue to flow water until manually shut off. 66 Main Street I North Easton,Massachusetts 02356 1 T 508.230.0260 1 F 508.230.0265 1 BERBER-engineering.com PA2017—All Projects\17219 Village Hill-Northampton MA\Correspondence\Narrative Report 35 Village Hill Road(FP FA Systems)07.10.19.docx 780 CMR 903.1.1 Narrative Report Village Hill,35 Village Hill Road—Northampton,MA/BER#17219 July 10,2019 Page 7 d. Flow test each water flow device and associated alarm interconnection to ensure an audible alarm is initiated within five 90 seconds of flow initiation and continues until flow stops. e. Flow test the standpipe at 250 GPM at the two(2)hydraulically most remote connections on the hydraulically most remote standpipe. f. The main drain valves shall be opened and remain open until the system pressure stabilizes. Static and residual pressures shall be recorded on the Contractor's test certificate. 5. A written report shall be submitted detailing the results of all final testing including: a. A copy of fire alarm control panel printer output verifying proper operation of each device in alarm or trouble,time stamped throughout the testing process. b. Final System Acceptance in accordance with NFPA-72 and BER Engineers project requirements shall be formally documented utilizing a form similar to"Record of Completion"as included in Figure 4.5.2.1 of NFPA-72. FIRE ALARM A) Preliminary Tests: 1. The Contractor shall notify the Owner's Representative 10 business days before the preliminary tests are to be conducted. 2. The Fire Alarm System and associated equipment shall be tested in accordance with NFPA 13, 14, and 72, and provisions of 780 CMR. 3. The Contractor shall perform insulation testing (megger), continuity and loop resistance checks on all system conductors to determine that the system is free from grounded, shorted, or open circuits. These tests shall be conducted prior to the installation of fire alarm equipment. Loop resistance measurement shall verify that the loop resistance does not exceed the Manufacturer's specified limits. Corrections shall be made and the system shall be retested to assure if deficiencies are found. 4. The Contractor and Fire Alarm System Manufacturer shall perform complete functional and operational performance tests. Testing shall include verification that the circuits and components are electrically supervised and operate as intended. 5. A written report shall be submitted detailing the results of all preliminary testing shall accompany the request for final acceptance test. The written preliminary test report shall be submitted with: a. Copy of fire alarm control panel printer output verifying proper operation of each device in alarm or trouble, time stamped throughout the testing process. b. The Operations and Maintenance Manual for the system. c. The record (As-built) drawings. 66 Main Street I North Easton,Massachusetts 02356 1 T 508.230.0260 1 F 508.230.0265 1 BER@BER-engineering.com PA2017—All Projects\17219 Village Hill-Northampton MA\Correspondence\Narrative Report 35 Village Hill Road(FP FA Systems)07.10.19.docx 780 CMR 903.1.1 Narrative Report Village Hill,35 Village Hill Road—Northampton,MA/BER#17219 July 10,2019 Page 6 C) The report of a power failure, ground fault or open circuit shall automatically: 1. Flash a supervisory LED and sound an audible signal at the fire alarm control panel. Upon Acknowledgement,the trouble LED shall light steadily and the audible shall silence. Subsequent trouble shall re-initiate this sequence. 2. Visually indicate the supervisory initiating device type and location via the LCD display located at the fire alarm control panel. D) All major equipment added shall be identified with signage indicating location and unique operational and design features readily apparent and or delineated with additional signage affixed adjacent to the equipment. E) Activation of dwelling unit smoke detectors s hall sound integral alarm signal only within unit and shall send a supervisory signal to control panel. All dwelling unit smoke detectors shall be programmed such that when one detector is activated all detectors within the unit of incidence shall sound. (1.0 TESTING CRITERIA Section 1 —Testing Criteria FIRE SUPPRESSION A) Final Acceptance Test: 1. The Contractor shall notify the Owner's Representative a minimum of five (5)business days before the Final Acceptance tests are to be conducted to allow scheduling of observation if desired. 2. The Contractor shall notify the Authority Having Jurisdiction a minimum of five (5) business days before the Final Acceptance tests are to be conducted to allow scheduling of observation if desired. 3. The Fire Suppression System and associated equipment shall be tested in accordance with NFPA 13, 14,and 24, and provisions of 780 CMR. 4. The testing shall include but shall not be limited to the following: a. Receipt of complete and signed Contractor's material and test certificates b. Hydrostatic testing of all interior piping to 200 psi shall be conducted, which shall be maintained for two (2)hours without pressure loss. Pressure gauge shall be installed at the low elevation point in the system. c. The backflow preventor assembly shall be forward flow tested to ensure proper operation at maximum system demand. 66 Main Street I North Easton,Massachusetts 02356 T 508.230.0260 1 F 508.230.0265 1 BER@BER-engineering.com PA2017—All Projects\17219 Village Hill-Northampton MA\Correspondence\Narrative Report 35 Village Hill Road(FP FA Systems)07.10.19.docx 780 CMR 903.1.1 Narrative Report Village Hill,35 Village Hill Road—Northampton,MA/BER#17219 July 10,2019 Page 8 B) Final Acceptance Test: 1. The Contractor shall notify the Owner's Representative a minimum of five (5)business days before the final acceptance tests are to be conducted to allow scheduling of observation if desired. 2. The Contractor shall notify the Authority Having Jurisdiction a minimum of five (5) business days before the final acceptance tests are to be conducted to allow scheduling of observation if desired. 3. The Fire Alarm System, other systems and equipment associated with the Fire Alarm System and accessory equipment shall be tested in accordance with NFPA-72. The listed tests in NFPA-72 shall be conducted as well as Manufacturer and job specific procedures to verify that the circuits and components are electrically supervised and operate as intended. 4. The test shall include but shall not be limited to the following: a. Visual inspection of all wiring connections. b. Test of each function of the control panel. c. Test of each circuit in both trouble and normal modes. d. Tests of each alarm initiating device in both normal and trouble conditions. Open the circuits at each alarm-initiating device to test the wiring supervisory feature. e. Tests of each control circuit and device. f. Tests of each alarm notification appliance, in both. Open the circuit as each notification appliance to test the wiring supervisory feature. g. Provide copy of fire alarm control panel printer output verifying proper operation (alarm,trouble, etc.) for each device with time stamp enabled throughout the testing process. h. Tests of the primary and secondary power supplies and associated loss of each. i. Complete operational tests under emergency power supply. j. Ground fault monitoring circuit function. k. Measurement of sound pressure levels in all rooms of the protected space. 5. A written report shall be submitted detailing the results of all final testing including: a. Copy of fire alarm control panel printer output verifying proper operation of each device in alarm or trouble, time stamped throughout the testing process. b. Final system acceptance in accordance with NFPA-72 project requirements shall be formally documented utilizing a form similar to "Record of Completion"as included in NFPA-72. END OF NARRATIVE 66 Main Street I North Easton,Massachusetts 02356 1 T 508.230.0260 1 F 508.230.0265 1 BER@BER-engineering.com PA2017_All Projects\17219 Village Hill-Northampton MA\Correspondence\Narrative Report 35 Village Hill Road(FP FA Systems)07.10.19.docx MUNICIPAL WATER AVAILABILITY APPLICATION Northampton Water Department 237 Prospect St Northampton,MA 01060 413-587-1097 A Department of Public Works Trench Permit shall be required prior to any construction or connection activity associated with this application. Location: 35 VILLAGE HILL ROAD Inquiry Made By: MARK FOLLETT 413-467-9171 (Name) (Telephone Number) Date of Inquiry: 2912019 Fire Line X Irrigation Domestic.X Number of Units: SEE ATTACHED Type of Units: Type of Ownership: Single Family Private X Apartments X Condo Multi-Family Rental X Commercial X _(Applicant to fill out the above] Municipal Water Main in Front of Location: Yes X No Existing service to site? Yes X No Size of Water Main: 12" Material: Ductile Iron Age: 2005 Approximate Static Street Pressure: 65 Flow Test Conducted: Yes No X (If flow test conducted attach results) Size of Service Connection: 6" Suggested Meter Size: 2" Comments: Domestic service to be taken off of fire line outside of building. Stub line shown on original plans.Stub line enters on Olander. - A corresponding water enterance fee shall be paid prior to making any connection to the municipal water system. -Arrange such installation shall be made with the Northampton Water Department within a mi m of 5 orki days tion. -All work sh 1 confor t Nor amp n Water Department specifications. p, (Water Superintendent) (Date) *Water Entry X ($1,250)Domestic *Meter $ 1525 *Radio Read $150 ($2,500)Subdivision (fee to be determined) (Includes fire line if required) cc: City of Northampton Building Dept/Commissioner NOTE:If this availablitiy is for a new construction,it must be hand delivered to the Building Inspector *Fees will be charged based on current fee structure at the time of entry application (� MUNICIPAL SEWER AVAILABILITY APPLICATION Northampton Streets Department 125 Locust Street Northampton, MA 01060 413-587-1570 A Department of Public Works Trench Permit and Sewer Entry Permit shall be required prior to any construction or connection activity associated with this application. Location: 35 VILLAGE HILL ROAD Date of Inquiry: 07/29/19 Inquirer with contact info: MARK FOLLETT 413-467-9171 WESTERN BUILDERS Reason for Request: NEW CONSTRUCTION Municipal Sewer Main in Front of Location: Yes No +r Size of Sewer Main: k' Material: P Age: Oq t Depth of Sewer Main: Length of Sewer Main: -v f`Zc_ Size of Service Connection: ti Type of Service Connection: f{-vtp (-keAl,yf Domestic Tie In: ($1,250) Subdivision Tie In : ($2,500) Tie-in to Private Sanitary: $- N/A Tie-in to Existing Sanitary Service: $- N/A Comments: City Requires 6" cleanout installed at City Property Line Note:If this availability is for new construction,this form must be hand delivered to Building Inspector. A corresponding"sewer entrance fee"shall be paid prior to making any connection to the municipal sewer system.Arrangements of such installation shall be made with the Northampton Streets Department with a minimum of S working days notificaiton. All work shall conform to Northampton Streets Department specifications. �-•"�` Date: i;-/y Sewer Dept. Foreman *Sewer Ent $ �' / V *Fees will be charged based on current fee structure at the time of entry application MUNICIPAL STORM DRAIN AVAILABILITY APPLICATION Northampton Department of Public Works 125 Locust Street Northampton,MA 01060 A Department of Public Forks Trench Permit and Storm Drain Entry Permit shall he required prior to any construction or connection activity associated with this application, Location:_ 35 Village Hill Road,Northampton MA 01060 Inquiry Made By: Mark Follett,Western Builders Inc Date of Inquiry: September 6,2019 Size of Proposed Connection 12" Material: DOPE (Attach plan and specifications of proposed connection) Source of Drainage Proposed to Discharge to Municipal Drain System: Driveway Parking Lot: Exterior Foundation Foot Drain: Roof: Sump Pump (Clean Discharge Agreement attache ) Other(describe): Catch basinlrain garden Type of Mitigation Prior to Connection to Municipal Drain System X Flow Reduction(i.e.infiltraion,detention system) Dater Quality Treatment: Applicant fill out down to this line •" Municipal Storm Drain Available: Yes: , No: .� Ei p r �{ Size of Municipal Drain Line tl � Material: 6� Age: Type of Service Connection: Tie-in to Storm Drain Manhole Tie-in to Catch Basin tt,, Domestic Tie-in($1,250) Subdivision Tie-in(52,500) Comments: EAXAli1�0\ or N4k A corresponding"storm drain enterance fee"shall be paid and storm drain connection permit approved prior to making any connection to the municipal drain,system. Arrangements of such installtion shall be made with the Northampton Streets Department with a minimum of 5 working days notification. All work shall confonr to Northampton Streets Department specifications. Sewer Foreman or designee Stormwater Manager or designee, as to MS4 Compliance Cc: Louis Hasbrouck, Building Commissioner "Storm Drain Entry$_ "Fees will be charged based on current fee structure at the time of entry application �N orftury O 0n Louis Hasbrouck<Iasbrouck@northamptonma.gov> Foundation permit Louis Hasbrouck <Iasbrouck@northamptonma.gov> Fri, Oct 11, 2019 at 12:46 PM Draft To: "Follett, Mark" <mfollett@westernbuilders.com> Cc: Jonathan Flagg <jflagg@northamptonma.gov> Mark, Here's a copy of the building permit for the foundation at 35 Village Hill Rd. and approved foundation plans.We still need the recorded stormwater agreement and the commercial energy review before we issue the full permit. Louis Hasbrouck Building Commissioner City of Northampton Town of Williamsburg (413) 587-1240 office (413) 587-1272 fax 2 attachments 35 VHR STRUC Plans foundation.pdf 1698K 35 VHR BP-20-34 Foundation.pdf 16K