16D-004 (13) 202 NORTH MAIN ST BP-2020-0626
GIs#: COMMONWEALTH OF MASSACHUSETTS
Map:Block: 16D-004 CITY OF NORTHAMPTON
Lot:-001 PERSONS CONTRACTING WITH UNREGISTERED CONTRACTORS
Permit: Building DO NOT HAVE ACCESS TO THE GUARANTY FUND (MGL c.142A)
Categoa: SOLAR ELECTRIC SYSTEM BUILDING PERMIT
Permit# BP-2020-0626
Proiect# JS-2020-001052
Est.Cost: $23997.00
Fee: $75.00 PERMISSION IS HEREBY GRANTED TO:
Const.Class: Contractor: License:
Use Group: VALLEY SOLAR LLC 077279
Lot Size(sq.ft.): 43995.60 Owner: David Velez
Zoning: URB(75)/URA(25)/ Applicant. VALLEY SOLAR LLC
AT. 202 NORTH MAIN ST
Applicant Address: Phone: Insurance:
PO BOX 60627 (413) 584-8844 WC
FLORENCEMA01062 ISSUED ON.1111312019 0:00:00
TO PERFORM THE FOLLOWING WORK.-22 PANEL SOLAR ARRAY - 7.7KW
POST THIS CARD SO IT IS VISIBLE FROM THE STREET
Inspector of Plumbing Inspector of Wiring D.P.W. Building Inspector
Underground: Service: Meter:
Footings:
Rough: Rough: House# Foundation:
Driveway Final:
Final: Final:
Rough Frame:
Gas: Fire Deaartment Fireplace/Chimney:
Rough: Oil: Insulation:
Final: Smoke: Final:
THIS PERMIT MAY BE REVOKED BY THE CITY OF NORTHAMPTON UPON VIOLATION OF
ANY OF ITS RULES AND REGULATIONS.
Certificate of Occupancy Signature:
FeeType: Date Paid: Amount:
Building 11/13/2019 0:00:00 $75.00
212 Main Street,Phone(413)587-1240,Fax:(413)587-1272
Louis Hasbrouck—Building Commissioner
Department use only
ui City of Northampton Status of Permit:
r '`O
Building Department Curb Cut/Driveway Permit
A , * 212 Main Street Sewer/Septic Availability
� - Room 100 \ Water/Well Availability
Northampton, MA 01060 laaco Sets of Structural Plans
phone 413-587-1240 Fax 413-587-1 72 r` 6i ns
/ o
APPLICATION TO CONSTRUCT,ALTER,REPAIR, R ON TEF1E OLISH A O OR O FAMILY DWELLING
SECTION 1 -SITE INFORMATION �Fn,GoF 019
1.1 Property Address: oN^�F / ct" n to a completed
�rby office
p1Gs pNs
Map l� Lo Cno C4 Unit
206 N Main St Florence, MA 01062 Zone Overlay District
Elm St.District CB District
SECTION 2-PROPERTY OWNERSHIP/AUTHORIZED AGENT
2.1 Owner of Record:
David Velez 206 N Main St Florence, MA 01062
Name(Print) Current Mailing Address:
617-699-7771
Telephone
Signature
2.2 Authorized Agent:
Valley Solar LLC PO Box 60627, Florence, MA 01062
Name(Print) Current Mailing Address:
x�ro�ran. (� xl;.a�rony, nn. 413-584-8844
Signature Telephone
SECTION 3-ESTIMATED CONSTRUCTION COSTS
Item Estimated Cost(Dollars)to be Official Use Only
completed by permit applicant
1. Building (a)Building Permit Fee
2. Electrical (b) Estimated Total Cost of
Construction from 6
3. Plumbing Building Permit Fee
4. Mechanical(HVAC) *-7S
5. Fire Protection
6. Total=(1 +2+3+4+5) q Check Number
This Section For Official Use Only
BuildingPermit Number: Date
Issued:
Signature: qu 10AA go3
Building Commissioner/Inspector of Buildings Date
Ihasbrouck @ northamptonma.gov
info valleysolar.solar
EMAIL ADDRESS (REQUIRED; CONTRACTOR)
SECTION 5-DESCRIPTION OF PROPOSED WORK(check all applicable)
New House ❑ Addition ❑ Replacement Windows Alteration(s) ❑ Roofing ❑
Or Doors 0
Accessory Bldg. ❑ Demolition ❑ New Signs [0] Decks [M Siding [O] Other[X solar
Brief Description of Proosed
Work: Instalfatlon of a 22 Panel solar roof mount array. System size 7.7 kW DC.
Alteration of existing bedroom Yes No Adding new bedroom Yes No
Attached Narrative Renovating unfinished basement Yes No
Plans Attached Roll - Sheet
6a. If New house and or addition to existing housing, complete the following:
a. Use of building : One Family Two Family Other
b. Number of rooms in each family unit: Number of Bathrooms
c. Is there a garage attached?
d. Proposed Square footage of new construction. Dimensions
e. Number of stories?
f. Method of heating? Fireplaces or Woodstoves Number of each
g. Energy Conservation Compliance. Masscheck Energy Compliance form attached?
h. Type of construction
i. Is construction within 100 ft. of wetlands? Yes No. Is construction within 100 yr. floodplain Yes No
j. Depth of basement or cellar floor below finished grade
k. Will building conform to the Building and Zoning regulations? Yes No.
I. Septic Tank City Sewer Private well City water Supply
SECTION 7a-OWNER AUTHORIZATION-TO BE COMPLETED WHEN
OWNERS AGENT OR CONTRACTOR APPLIES FOR BUILDING PERMIT
David Velez as Owner of the subject
property
hereby authorize Valley Solar LLC
to act on my behalf, in all matters relative to work authorized by this building permit application.
11/07/2019
Signatu n Date
Valley Solar LLC as Gwpw/Authorized
Agent hereby declare that the statements and information on the foregoing application are true and accurate, to the best of my knowledge
and belief.
Signed under the pains and penalties of perjury.
Steven Silverman
Print Name
"&
/fit, Q.. 11/05/2019
Signature of Owner/Agent Date
SECTION 8 -CONSTRUCTION SERVICES
8.1 Licensed Construction Supervisor: Not Applicable ❑
Name of License Holder: Steven Silverman
License Number
06 fl bY2�1CP, m i� 0- CS-077279
Address Expiration Date
6/21/2020
Signature Telephone
413-584-8844
9. Registered Home Improvement Contractor: Not Applicable ❑
Company Name Registration Number
Valley Solar LLC 186338
Address Expiration Date
PO Box 60627, Florence, MA 01062 Telephone 413-584-8844 10/27/20
SECTION 10-WORKERS' COMPENSATION INSURANCE AFFIDAVIT(M.G.L. c. 152, § 25C(6))
Workers Compensation Insurance affidavit must be completed and submitted with this application. Failure to provide this affidavit will result
in the denial of the issuance of the building permit.
Signed Affidavit Attached Yes.......V No...... ❑
5 r z
SYSTEM BRIEF
B Installation of a 22 panel,6.38 AC Size(kW),7.7 * r
s DC Size(kW),roof mount PV solar system. �; ti
{ - i .
PLAN LEGEND • ! 2 01
r
i m
Roof Arrav DO t z a
s 22x LG350NIC-V5 solar PV modules �
>o '
22x Enphase IQ7PLUS-72-2-US micro-
ODOpOO
inverters aaOO
SnapNRack Ultra Rail mounting system
� DOOO ��♦ �, W� s
a Intemal Wall of House N N
& Enphase Combiner Box(N)
1 AC Disconnect(N) !
Main Electrical Panel(E) f
External Wall of House Z
Utility SMART Generation Meter(N) ` w
AC Disconnect(N) Cn
® ro
s Utility Meter(E)
�a
ps _
UTILITY INFO
Utility Company National Grid -_
Utility Customer of Record David Velez g
Utility Acct#61078-92013
a Meter Number 25037700 _ g
Address 206 N MAIN ST FLORENCE MA 01062
E �a
a
'L T
AN
+ .. sc.c= 4 03
- Bk:1220 Py:238
Nq
° NAYYAGN-.9titY ExOlat'Ax
Hl+pa.r1 D'wlrW RW 118001 .�..
.IyI
OW2116.Jm Word?. W
w.16166.0e0.0o W Y
a ¢ U
a 0 N O
J
€ DEED >v~j o
3
,;oslad t Associates, P.C., a Massachusetts professional ¢ G
corporation, havinq offices at 83 Superior Avenue, Indian Orchard, O=
Maasachueetta, for consideration paid in the amount of Four
'x Hundred Eifty E' T. - n nd 00/100 00) DOLLARS, -
3 II hereby grants to. of 206 North J
3 ( Main Street, Northamton, assac use s, as Tenants by the w
Entirety, with Ooitc-taim Covenants, the property located at 206 '$ u�W�
North Main Street, Northampton, Hampshire County, Nassaohuse-t.' 9 W C
5 i (n
being sore particularly bounded and described as :chows:
SEE EXHIBIT A FOR LEGAL DESCRIPTION t >
g
ffThin conveyance does not constitute a transfer cf all or
33 +.stantia;ly all at the assets of the grantor.
3
`
! Executed as a sealed instrument this 25th day of k'ebruar y, W
202 NORTH MAIN ST Z
rv76,
NORTHAMPTON O
$a aosuiD c AssoclATes, P.C. ne' CROMLEY ROBERT G&ELLEN K d
s T)'GUAS DR
` TORSS 1AANSr rELC
By. Joseph E. and Alma, Bu#ding/ajuv :14.200
Presidz Treasurer OmerVark Lard aQ13 ..500 I A
Total Value: $127,700
Asses3merrt data'rom FY 201+ >
Lo!Size =0%Acres
*$ Last Sale Fnce. S1125.000 g
g Last Sale Date 20131220
s Use Code 130
Year Built: >
ate.
CO
g� r
a2
f
a
a SYSTEM BRIEF
iu
' Installation of a 22 panel,6.38 AC Size(kW),7.7
DC Size(kW),roof mount PV solar system. tg Y
PLAN LEGEND +► ~
Roof Arrav
v_ 2Y
22x LG350N1C V5 solar PV modules Q�QQ \ : sQ
22x Enphase 1O7PLUS-72-2-US micro-inverters
m
SnapNRack Ultra Rail mounting system
y� W
44
# � a 2
x
B Internal Wall of House _' c
Enphase Combiner Box(N)
AC Disconnect(N) —
Main Electrical Panel(E) y '
External Wall of House
Utility SMART Generation Meter(N) a
AC Disconnect(N)
Utility Meter(E) ® in
UTILITY INFO
Utility Compar National Grid
Utility Customer of _ rd David Velez o o'
Utility Acct#61078-92013 S o a
Meter Numi,. 25037700 " j m
Addres 206 N MAIN ST FLORENCE MA 01062 b2
a
T
v-
TRIS I II C'RIC.11_nft AWING ISA-R OSE.DESIGN.THE ELEC`ns 115 AT LIBERTY TO ADJUST DURING THE WILD ANO AMENDMENTS WILT HE REFLECTED W THE A—ILT DIAGRAM.
System Comoonents:0
Inverter Trio Settings: Labelina Schedule
a
1) Snap&Rack Ultra Rail racking BOM Inverter TRIP setfincis are set in the inverter per the Iso NE SRO and ESB 758 section 7,8.11, 1)WARNINGI PHOTOVOLTAIC POWER SOURCE s
2) 22x(LG350N1C-V5)PV modules DEVICE DEFAULT PICKUP I DEFAULT CLEARING Pickups and 2 SOLAR PV AC COMBINER BOX a
g 3) 22x(IQ7PLUS-72-2-US)Enphase microinverters sernrlo ! nME(seconds) Clearing Times )
g
(simplified defaults I Adhere to Required 3)PV SYSTEM AC DISCONNECT Rated AC Output Current:26.62
2x(Q-SEAL-10)Sealing Cap For Q Cable S
2x(Q-TERM-1 Terminal Ca For Q Cable from 5ecn°"T.B.,,) Defaults(YecMo): AAC Nominal Operating Voltage:240V AC 3 o W
( ) p Under Frequency 56.5 Hz 0.18 Yea 4)RAPID SHUTDOWN SWITCH FOR SOLAR PV SYSTEM
4) 1x(RSTC 0799-5B)Blk Soladeck (81U) 0
(reflective)
Z
5) 1x(X-IQ-AM1-240-3)Enphase Combiner Box Under Frequency 58.5 Hz 300 Yes
a 5 WARNINGI ELECTRICAL SHOCK HAZARD TERMINALS ON Ir
e 2x(BR220)20A 2P PLUG-IN 120/240V 181u) O
1x(CT-200-SPLIT)set of 2 consumption CTs Over Frequency(810) 111.2 Hz 300 Ye, BOTH LINE AND LOAD SIDES MAY BE ENERGIZED IN THE m u-N -
1 x(DLA LA-302R)1 P3W 250V Lightning Arrestor Over Frequency(810) 82.0 Hz 0.16 Yes OPEN POSITION >(n b
V Undarvokege(2T) sox of Nominal 1.1 vas 6)UTILITY GENERATION METER o
6) 1x(DG222URB)EATON 60AAC Disco non-fused UnderVofige(2T) 88%ofNominal 2 Yee 7)WARNING BUSBAR IS ENERGIZED FROM 2 SOURCES o v
7) 1x(U5934)Milbank 60A 1 PH 3W meter socket Over Voltage(59) 110%of Nominal 2 Yes UTILITY GRID AND PHOTOVOLTAIC SYSTEM Z
8) Main Service Load Center 200A main CB Over Voltage(59) 120%of Nominal 0.1e vas g)WARNING!INVERTER OUTPUT CONNECTION DO NOT
1x(BR235)35A 2P PLUG-IN 120/240V RELOCATE THIS OVERCURRENT DEVICE N
9) Utility Service Meter 120/240V 1 PH 3W 9)WARNING!UTILITY METER ENERGIZED BY 2 SOURCES ul o
10)UTILITY SERVICE METER < w
B
LINE on the top and the N
AC Isolation Device between
� MOD 17 MOD MOD MOD 1 Company meter R DER AC Isolation Device. LOAD on the bottom sideAC Isolation Device
of the MA SMART Meter Q�
a
MICROW Q'
8 INVERTERS 2IN
vC,# W 8 7 Q
C RCUITH 5 1 2 WWService Panel O
SMART Meter _jAC AC AC AC 3 AC Combiner Box 3 Q
a DC DC DC DC 4
J•sox b 4 5
I b C1 9 10 w
— ^ AC Disco w
kWh g
tpg I MICRO (1)01013 I --- zPak 3o To/ o orifi
g I INVERTERS (1)a10Green ce E
IN 3!4'EMT From
IN C RRCUITH _- ^""" 10f3 RX 10/3 RX 1013 RX p
.l A offset 8 Utility i g
nipple Houae N >
AC AC AC AC PRooucTloNcu GEC ` 8
DC DC DC DC
_ U K
D.
yt (1)06 CU THHN (2)012 CU THWN•2. c
3 EGC D Cable
Utility Info:
Lr
b Utility Company National Grid Communications: Conductor/OCPD Calculations:
Utility Customer David Velez
Utility Acct#61078-92013 Wifi to Envoy or CATS TBD (NEC 210.19(A)(1)(a)).Inverter IQ7PLUS-72-2-US Max ,,
a Meter Numt/ 25037700 Output=1.21A x 22=26.62A x 1.25=33.275A
Address 206 N MAIN ST FLORENCE MA 01062
Penn FUSION 1 52 S. Broad
E n y l n ■ ® Ir l n y Lansdale, PA 1944466
(215)361-8040
November 12, 2019
Valley Solar
340 Riverside Dr
Northampton, MA 01062
RE: Velez Residence
206 N Main St, Northampton, MA 01060
Client Project#:206VELE
PFE Project#: 194524
On behalf of Valley Solar, Penn Fusion Engineering LLC (PFE) performed a structural analysis of the roof at the above
referenced location.The purpose of our analysis was to determine if the existing roof system is structurally sufficient to
support the new photovoltaic moudles in addition to the code required design loads. Our analysis is based on the information
provided by Valley Solar and is isolated only to the areas where the modules are intended to be placed.
System Specifications:
Total System Size: 7.7 kW/DC
Panel Specs: (22) LG Solar-LG350N 1 C-A5
Inverter Specs: (22) Enphase-IQ7+
Racking System: SNAPNRACK- UR
The modules are to be located on the following roof plane:
Mounting Rafter Rafter Horizontal Collar Collar Tie Shingle Number of Ceiling
Plane Size Spacing Span Ties Spacing Sheathing Type Shingle Layers Profile
1 2x10 16" 1 7ft. Sin. N/A 0" CDX 1/2" Asphalt 1 Flat
Shingles
The roof design has been analyzed in accordance with the 2015 International Residential Code and Massachusettes
Amendments 9th Edition with design loads as follows:
Ground Snow(Pg): 40 psf
Wind Speed (V): 1 1 7 mph
Mounting Plane 1
The calculations for these structural members are attached. It has been determined by this office that the roof, as specified
above, is adequate to support the new PV modules in addition to the code required design loading.
Attach the module rail brackets to the roof with 5/16" lag bolts at 48 on center maximum with staggered penetration such
that load is distributed evenly among roof members. Provide a minimum of 2" of penetration into the wood members.
This office has determined that the installation of the PV System as specified above will meet the structural requirements of
the 2015 International Residential Code with Massachusettes Amendments 9th Edition and ASCE7-10 when installed in
accordance with the manufacture's instructions.
If you have any questions regarding this analysis, please feel free to contact us.
OF 141
Best Regards, �,� cy
Penn Fusion Engineering LLC o
ANDREW DOVEv C m
LEO%E
J
NO 53C4.L.—
Andrew D. Leone, P.E. T� -
Principal FISTS
SS�OAIAL Eta'
Penn FUSION 152 S. Broad
Lansdale, PA 19446
E n g I n ! e r I n Q (267)640-2758
Client Name: Valley Solar
PFE Project Number: 194524
Client Project Number: 206VELE
Project: Velez Residence
Address: 206 N Main St
Northampton, MA 01060
Description: Mounting Plane 1
Calculations By: ADL
Date: November 12, 2019
Roof Construction
2x10 Rafters at 16"on center
A= 13.88 int
Ix= 98.93 in'
Sx= 21.39 in
Wood Species= Doug-Fir Larch#2
Fb= 900 psi
Fv= 180 psi
E= 1600000 psi
Roof Slope= 0 °
Rafter Span= 17.42 ft
Ceiling Attached to Rafters?: No
Design Criteria
Ground Snow(Py): 40 psf
Design Wind Speed: 1 1 7 mph
Live Load: 20 psf
Dead Load: 4.81 psf
PV Modules: 3 psf
Wind Calculations
Directionality Factor(Kd): 0.85
Topographic Factor(KZt): 1
Velocity Pressure Exposure 0 7
Coefficient(KZ):
Importance Factor(1): 1
Velocity Pressure(qz): 20.85 psf
Tributary Square Footage on 10.83 ft2
Component:
Component Roof Pressures: 9.94 / -60.9 psf
Snow Load Calculations
Exposure Factor(Ce): 1
Thermal Factor(Ct): 1
Importance Factor(1): 1
Flat Roof Snow Loads(Pf): 35 psf
Roof Slope Factor(CS): 1
Sloped Snow Loads (PS): 35 psf
Unbalanced Snow Load: 0 psf
Member Calculations
Bending
Md: 1810.27 ft*Ib
fb: 1015.55 psi
Load Duration Factor(Cd): 1.15
Stability Factor(CO: 1
Wet Service Factor(CM): 1
Temperature Factor(CT): 1
Size Factor(CF): 1.1
Flat Use Factor(Cf.): 1
Incising Factor(C): 1
Repetitive Member Factor(C,): 1.15
Fb: 900 psi
F'b: 1309.28 psi 1015.55<=1309.28 OK in Bending
Shear
Vd: 415.76 Ib
fV: 44.95 psi
Load Duration Factor(Cd): 1.15
Wet Service Factor(CM): 1
Temperature Factor(CT): 1
Size Factor(CO: 1.1
Flat Use Factor(Cf„): 1
Incising Factor(C): 1
F,,: 180 psi
F'v): 207 psi 44.95<=207 OK in Shear
Deflection
Live Load Deflection A): 0.49 in L/428 OK in Live Load
Deflection
Total Load Deflection 04 0.62 in L/335 OK in Total Load
Deflection
Uplift Calculation
Tributary Square Footage on 10.83 ftz
Component:
Uplift Pressure: -60.9 psf
Uplift per Lag: -659.79 lbs
Lag Screw Diameter: S/16 in
Allowable Withdrawal per Inch: 490.99 lbs/in
Minimal Screw Penetration: 1.34 in
Install 5/16"diameter lag screws @ 48 on center with
minimum penetration of 2" into rafter.
T
LG350N1 C-V5
350W
The LG NeONe 2 is LG's best selling solar module,and is one of the most
powerful and versatile modules on the market today.Featuring LG's Cello
Technology,the LG Ni 2 increases power output.New updates include
an extended performance warranty from 86%to 90M%to give customers
higher performance and reliability.
ra�uct
DVE C UL US C E
I
t• :r•
r,
Features
Enhanced Performance Warranty Enhanced Product Warranty
�'''-�• 25yrs
LG NeONe 2 has an enhanced LG has extended the warranty of the
performance warranty.After 25 NeONe 2 to 25 years including labor,
years,LG NeONll 2 is guaranteed at which is top level in the industry.
least 90.08%of initial performance.
Better Performance on a Sunny Day Roof Aesthetics
LG Ni 2 now performs better on LG NeON®2 has been designed with
sunny days,thanks to its improved aesthetics in mind using thinner wires
temperature coefficient. that appear all black at a distance.The LG
NeONe 2 can increase the aesthetic value
of your home with a more modern design.
When you go solar, ask for the brand you can trust: LG Solar
About LG Electronics
LG Electronics is a global leader in electronic products in the clean energy markets by offering solar PV panels and energy storage systems.The company first embarked on a solar LG Solar
energy source research program in 1965,supported by LG Group's vast eapenence in the semi-conductor,LCD,chemistry and materials Industries.In 2010,LG Solar successfully
released its first MonoXe series to the market,which is now available in 32 countries.The NeONe(previous MonoXe NeON),NeONe2,NeONe2 Bil'acwl won the"Intersolar
AWARD",n 2013,201 Sand 2016,which demonstrates LG's leadership and innovation in the solar industry.
LG350N1C•V5.Indd 1 6/27/19 1:02 PM
LG NeON®2
LG350N1C-V5 Preliminary
General Data Electrical Properties(STC*)
Cell Properties(Material/Type) Monocrystalline/N-type Model LG350N1 C-VS
Cell Maker LG Maximum Power(Pmax) (W] 350
Cel(Configuration ;}: 60 Cells(6 x 10) MPP Voltage(Vmpp)
Number of Busbars 12EA MPP Current Impp) [AJ 9.92
Module Dimensions(L x W x H) 1,666mm x 1,016mm x 40 mm Open circuit Voltage(voc, 5%) [V] 41.3
Weight 17.1 kg Short Circut Currerrt(1.,-5%) [A] 10.61
_ ---------
_
Glass(Material) Tempered Glass with AR Coating Module Efficiency- [%] _20.4 -
Backsheet(Cdo) ..- _ Whim --- _ PoiverTdknnce_. 1%),.. ... 0-+3._
Frame(Material) - _-- Anotllzed Alumlrnum-__ - -STC(Standard Test Condition)Irradiance 1000 W/m',n8 temperature 25 Y,AM 1.5,Measure Tolerence'3%
)unction Box(Protection Degree) IP 68 with 3 Bypass Diodes
Cables(Length) 1,000mmx2EA Operating Conditions
Connector Mpe/Maker) MC 4/MC Operating Temperature- -- -[°C] ]�, -40-+90
Mammum System Voltage [V] 1000 IEC
Maximum Series Fuse Rating [A] 20
Certifications and Warranty ----------__----___.._..--.----..--
Mechancal Test Load`(Front) [Pa/psf] 5,400/113
IEC 61215_1/-1-1/2.2016,IEC 61730-1/22016 Mechanical Test Load*(Rear) 4,000/84
Certifications ISO 9001,ISO 14001,ISO 50001 -_ _ *Mechanical Test Loads 5,400 Pa/4,000 Pa based on IEC 61215-2:2016(Test Load-Design Load x Safety
OHSAS 18001 Factor(1.5))
Sate Misc Corrosion rest IEC 617012012 Severity 6
Packaging Configuration
Ammonia Corrosion Test IEC 62716:2013 --
- --- Number of Modules per Pallet : [EA] 25
Fire Rating Cbus C(UL 790) -- -- -
- - - --- - -- Number of Modules per 40ft HO Container [EA] 650
Solar Module Product Warranty :` '� 25 Wars - - - -
-.. --- ...........__._.. — __. Packaging Box Dimensions(L x W x H) [mm] 1,750 x 1,120 x 1,221
Solar Module Output Warranty year 0.33%/ Linear Warranty -.. -.
roved:1st 98%,from]24th year down,after 25th year:90.08% Packaging Box Gross WeugM„ [kg] _ 464
'Im
Temperature Characteristics Dimensions(mm/inch)—
NMOTa --IT]—T_ --_ 42 t 3
-036
Voc [%/°C] -0.27
0.03 em,or41.� [Ixvt:mmlrkl
-NMOT(Nominal Module Operating Temperature).Irradiance 800 W/m2,Ambient amperatum 20
Wind speed 1 m/s,Spectrum AM 1.5
i t AzVio z---
ElectricalProperties(NMOT)
Model .LG350Nit-1f9 �x`� m m.
Maxi mum Power(Pmax) [W] 261
MPP Voltage(Vmpp) M 33.0
MPP Current(Impp) (A] - ._-_---_ 7.91
OVoltage.. _.. �...'_.—_.__.__—__.__________..._.__—_...___.__.r___.._
Open (Va) [7 . 38.80
Short Circuit Current(iec); (A). i 8.53
e t
IN Curves
110 !
Io00w
10.0
snow
8.0
6.0 _.__......�'_._.-
u'
-
p
0.0
0.0 10.0 20.0 30.0 40.0 Voltage(V)
® LG LG Electronics Inc Product specifications are subject to change without notice.
Solar Business Division LG350N1C-V5_AUS pelf
2000 Millbrook Drive
Lincolnshire,IL 60069
Life's Good wwwAg-solarcom m 2019 LG Electronics.All rights reserved. Mir
LG350NiC-V5.indd 2 627/19 1:02 PM
Elwes The high-powered smart grid ready
Enph��. ,
"' and T.
IQ 7 and IQ 7+ dramatically simplify the installation process while
achieving the highest system efficiency.
Microinverters Part of the Enphase IQ System,the IQ 7 and
IQ 7+ Microinverters integrate with the Enphase
IQ Envoy`", Enphase IQ BatteryT", and the Enphase
Enlighten TM monitoring and analysis software.
IQ Series Microinverters extend the reliability
standards set forth by previous generations and
undergo over a million hours of power-on testing,
enabling Enphase to provide an industry-leading
warranty of up to 25 years.
Easy to Install
Lightweight and simple
Faster installation with improved,lighter two-wire cabling
Built-in rapid shutdown compliant(NEC 2014&2017)
Productive and Reliable
Optimized for high powered 60-cell and 72-cell*modules
More than a million hours of testing
Class II double-insulated enclosure
UL listed
0
Smart Grid Ready
11 ... Complies with advanced grid support,voltage and
' frequency ride-through requirements
Remotely updates to respond to changing
grid requirements
Configurable for varying grid profiles
Meets CA Rule 21 (UL 1741-SA)
*The IQ 7+Micro is required to support 72-cell modules.
UL
To learn more about Enphase offerings,visit enphase.com
0'_"' E N P I-1�4 S E
Enphase IQ 7 and IQ 7+ Microinverters
INPUT DATA(DC) IQ7-60-2-US IQ7PLUS-72-2-US
Commonly used module pairings' 235W-350W+ 235W-440W+
Module compatibility 60-cell PV modules only 60-cell and 72-cell PV modules
Maximum input DC voltage 48V 60V
Peak power tracking voltage 27 V-37 V 27 V-45 V
Operating range 16 V-48 V 16 V-60 V
Min/Max start voltage 22V/48V 22 V/60 V
Max DC short circuit current(module Isc) 15A 15A
Overvoltage class DC port II II
DC port backfeed current 0 A 0 A
PV array configuration 1 x 1 ungrounded array;No additional DC side protection required;
AC side protection requires max 20A per branch circuit
OUTPUT DATA(AC) IQ 7 Microinverter IQ 7+Microinverter
Peak output power 250 VA 295 VA
Maximum continuous output power 240 VA 290 VA
Nominal(L-L)voltage/range2 240 V/ 208V/ 240 V/ 208 V/
211-264 V 183-229 V 211-264 V 183-229 V
Maximum continuous output current 1.0 A(240 V) 1.15 A(208 V) 1.21 A(240 V) 1.39 A(208 V)
Nominal frequency 60 Hz 60 Hz
Extended frequency range 47-68 Hz 47-68 Hz
AC short circuit fault current over 3 cycles 5.8 Arms 5.8 Arms
Maximum units per 20 A(L-L)branch circuit3 16(240 VAC) 13(208 VAC) 13(240 VAC) 11 (208 VAC)
Overvoltage class AC port Ili III
AC port backfeed current 0 A 0 A
Power factor setting 1.0 1.0
Power factor(adjustable) 0.85 leading...0.85 lagging 0.85 leading...0.85 lagging
EFFICIENCY @240 V @208 V @240 V @208 V
Peak efficiency 97.6% 97.6% 97.5°% 97.3°i°
CEC weighted efficiency 97.0% 9 7.0% 97.0% 97.0%
MECHANICAL DATA
Ambient temperature range -40°C 11 to+65°C._
Relative humidity range 4°i to 100%(condensing)
Connector type(IQ7-60-2-US&IQ7PLUS-72-2-US) MC4(or Amphenol H4 UTX with additional Q-DCC-S adapter)
Dimensions(WxHxD) 212 mm x 175 mm x 30-2 mm(without bracket)
Weight 1.08 kg(2.38 lbs)
Cooling Natural convection-No fans
Approved for wet locations Yes
Pollution degree PD3
Enclosure Class II double-insulated,corrosion resistant polymeric enclosure
Environmental category/UV exposure rating NEMA Type 6/outdoor
FEATURES
Communication Power Line Communication(PLC)
Monitoring Enlighten Manager and MyEnlighten monitoring options.
Both options require installation of an Enphase IQ Envoy.
Disconnecting means The AC and DC connectors have been evaluated and approved by UL for use asthe load-break
disconnect required by NEC 690.
Compliance CA Rule 21 (UL 1741-SA)
UL 62109-1,UL1741/IEEE1547,FCC Part 15 Class B, ICES-0003 Class B,
CAN/CSA-C22.2 NO.107.1-01
This product is UL Listed as PV Rapid Shut Down Equipment and conforms with NEC-2014 and
NEC-2017 section 690.12 and C22.1-2015 Rule 64-218 Rapid Shutdown of PV Systems,for AC
and DC conductors,when installed according manufacturer's instructions.
1.No enforced DC/AC ratio.See the compatibility calculator at https://enohase.com/en-us/support/modulo-rmm�atibilitV
2.Nominal voltage range can be extended beyond nominal if required by the utility.
3.Limits may vary.Refer to local requirements to define the number of microinverters per branch in your area.
To learn more about Enphase offerings,visit enphase.com EN PHASE.
,D 2019 Enphase Energy All rights reserved.All trademarks or brands used are the property of Enphase Energy,Inc.
2019-3-26
REVISION:
SNAPNRACK UR-40 RACKING SYSTEM SNAPNRACK A uBa/2D17 NEW DErAlL MA
SHOWN MOUNTED ON ULTRA FOOT WITH MID CLAMP,
UNIVERSAL END CLAMPS.FOR TILE T,P =-
ROOFING USE SNAPNRACK TILE "RAIL END OVERHANG" ——
REPLACEMENT,UNIVERSAL TILE HOOK,OR NOT TO EXCEED 34%OF —
FLAT TILE HOOK SYSTEMS. ACCEPTABLE RAIL SPAN
STANDARD LAG SCREW SPEC ASSUMES SNAPNRACK UNIVERSAL END /
CLAMP ASSEMBLY,TYP.
She"0 LAG SCREW WITH 2%"MIN.
EMBEDMENT INTO STRUCTURAL MEMBER.
TORQUE SPECIFICATIONS: / ® SNAPNRACK ROOF ATTACHMENT
She"0 NUTS&BOLTS,10-16 FT--LBS SNAPNRACK UR-40 RAIL,TYP. (MODULE HIDDEN FOR CLARITY)
RAILS CAN BE MOUNTED ON EITHER SIDE
OF ULTRA FOOT;UPSLOPE OR
DOWNSLOPE.
DETAIL A
FOR UNEVEN ROOF SURFACES,UTILIZE
THE SNAPNRACK LEVELER,EXTENSION "RAIL SPAN"IS DEFINED AS
LEVELING SPACER.SEE DETAIL(S)
"UR40-DOI,""UR40-DO8,""UR40-D09,-& DISTANCE BETWEEN
"UR40-D10,"FOR DETAILS AND ROOF ATTACHMENTS
LIMITATIONS.
A
"STRUCTURAL MEMBERS)
MAY REFER TO RAFTERS,PURLINS,
BEAMS,OR OTHER STRUCTURAL,
LOAD-CARRYING MEMBERS
SNAPNRACK MID CLAMP,TYP;
CLAMP ASSEMBLY SHALL BE
SELECTED TO MATCH PV MODULE
"MODULE OVERHANG"
NOT TO EXCEED 2S%OF MODULE
LENGTH OR MODULE MANUFACTURERS
RECOMMENDATIONS
SNAPNRACK ROOF ATTACHMENT
LAG SCREWED INTO STRUCTURAL MEMBER.
NO FLASHING SHOWN FOR CLARITY.
;: _ _ _ Sum,South LLC DESIGNER: M.Affentranger SCALE: DNS PART NUMBER: DESCRIPTION: REV
���rL��(p) 1 :�G� E4 Asgaao..0 nsl Damp DRAFTER: M.Affentranger UR40-DO6 UR-40 TYPICAL LAYOUT
y DATE: 11/30/2017
('�,I+..t �i�'4q;-N4',i t"}U".15 �`m°A.�"o�".« s�,E oa�sF,»EaEo�s"Pa� w;TME APPROVED BY: G.MCPheeter5
SNAPNRACK Ug 40 RAIL SHOWN SPLICED REVISION:
TOGETHER WrM THE SNAPNRACK ULTRA 9 11[712017 NEW DETAIL MA
RAIL SPLICE. V4"RAIL GAP
2"MIN 2 MAX FOR THERMAL EXPANSION -_
TORQUE SPECIFICATIONS: AT SPLICES
%6"0 NUTS&BOLTS,10-16 FT-LBS
CENTER SPLICE BETWEEN THE TWO
BONDING CLIPS AS SHOWN IN"SPLICE
ALIGNMENT LIMITS"VIEW
. 0
RAIL EDGE MUST NOT PASS /. SPLICE ALIGNMENT LIMITS
THE CUP EDGE,AS SHOWN.
SNAPNRACK UR-40 RAIL,
TYP.
i
i
SNAPNRACK BONDING CUP,TYPE 2
e FOR BONDING ACROSS RAILS
6/16"0-18 BOLT,S.S.
SNAPNRACK ULTRA SPLICE ASSEMBLY,
CENTER ON RAIL GAP t 1"
SNAPNRACK ULTRA
SNAPNRACK ULTRA SPLICE,THRU
SPLICE,TAPPED
r� Sunrun South LLC DESIGNER: M.Affentranger SCALE: DNS PART NUMBER: RIPTION: REV
���-�)�S�n1 DRAFTER: M.AffentranUer
UR40-D05 UR 40 ULTRA SPLICE DETAILS
DATE: A
APPROVED BY: G.McPheeters 11/7/2017 DESC
11
City of Northampton
' Massachusetts
�• �'' 'fit
. � DEPARTMENT OF BUILDING INSPECTIONS es
212 Main Street •Municipal Building
Northampton, MA 01060
Debris Disposal Affidavit
In accordance of the provisions of MGL c 40, S54, I acknowledge that as a condition of the building
permit all debris resulting from the construction activity governed by this Building Permit shall be disposed
of in a properly licensed solid waste disposal facility, as defined by MGL c 111, S 150A.
The debris from construction work being performed at:
206 N Main St Florence, MA 01062
(Please print house number and street name)
Is to be disposed of at:
Valley Recycling. (235 Easthampton Rd, MA 01060)
(Please print name and location of facility)
Or will be disposed of in a dumpster onsite rented or leased from:
Valley Solar. (POB 60627, MA 01062)
(Company Name and Address)
Signature oer • Applicant or Owner Date
If, for any reason, the debris will not be disposed of as indicated, the Applicant or Owner shall notify the
Building Department as to the location where the debris will be disposed.
The Commonwealth of Massachusetts
$� Deparhinent of Industrial Accidentv
n
Office of Investigations
600 Washington Street
z : a Boston, MA 02111
www.mass.gov/dia
Workers' Coml)cnsation Insurance Affklavit: Builders/Contractors/FIectricians/Plumbers
yOicant Information Please Print Legibly
Nameu;asi►a:ssKhgani.xtimOndividlai): Valley Solar LLC
Address:340 Riverside Drive PO BOX 60627
City/State/Zip:Florence, MA 01062 Phone#: 413-584-8844
Are you an employer?Check the appropriate box: Type of project(required):
1.10 1 am a employer with 11 4• ❑ I am a general contractor and I
employees(full and/or part-time).* have hired the sub-contractors 6. New construction
2.❑ I am a sole proprietor or partner- listed on the attached sheet. 7. ❑Remodeling
ship and have no employees "These sub-contractors have g, ❑Demolition
working for me in any capacity. employees and have workers' 9 Building addition
[No workers'comp.insurance comp,insurance.:
required.] 5. 0 We are a corporation and its 10.❑Electrical repairs or additions
3.❑ I am a homeowner doing all work officers have exercised their 11.0 Plumbing repairs or additions
myself.[No workers'comp. right of exemption per MGL 12.❑Roof repairs
insurance required.]t c. 152,§1(4),and we have no
employees.[No workers' 13.®OtherSolar
comp.insurance required.]
*Any applicant that checks box#1 nunt also till out the s ction hclow shoving,their workers'compensation policy uIRIMIation
t I lomcowners who submit this affidavit indicating they are doing all work and then hire outside contractors must submit a new affidavit indicating such.
Contractors that check this box must attached an additional sleet showing the name of the sub-contractors and stale whether or not those entities have
employees ll the.sub-contractors have employees,they must provide their workers'comp.pulacy number.
I ant an employer dint is providing workers'coonpeinatioii insurance ft)r my employees. Below is the police and job site
infarnuaion.
Insurance Company Name:.Liberty Mutual
Policy N or Self-ins.Lic.#:WC531 S620647019 Expiration Date: 2/112020
Job Site Address: 206 N Main St city/State/zip:._Florence, MA 01062
Attach a copy of the workers'compensation policy declaration page(showing the policy number and expiration date).
Failure to secure coverage as required under Section 25A of MGL c. 152 can lead to the imposition of criminal penalties of a
fine up to S 1,500.00 and/or one-year imprisonment,as well as civil penalties in the form of a STOP WORK ORDER and a fine
of up to$250.00 a day against the violator. Be advised that a copy of this statement may be forwarded to the Office of
Investigations of the DIA liar insurance coverage verification.
do hereby eerttfy wale t ains amt p7ldes of Pr
a Infornurtion provided above is true and correct.
j • G
Si nature: j Date: (,� •__��) "
Phone#: 413-584-8844
Official use onll: Do not write in dols area,to he completed by city or low"official
City or Town: Permit/License#
Issuing Authority(circle one):
art of Health 2. Building Department 3.City/Town Clerk 4. Electrical Inspector 5. Plumbing Inspector
6.Other
Contact Person: 1'hunc!t: