31C-065 (2) 39 HIGGINS WAY - LOT 9 SM-2020-0016 COMMONWEALTH OF MASSACHUSETTS CITY OF NORTHAMPTON GIS#: 12215 _ Map: 31 C y Bock: '065 SHEETMETAL PERMIT Lot: !9 r� _ ,�� Permit: SHEETMETAL III Category: SHEETMETAL Permit# ;SM-2020-0016 PERMISSION IS HEREBY GRANTED TO: Project# !JS-2019-001929 Est.Cost: $9,000.00 Contractor: License: Expires: Fee Charged:$50.00 RICHIES AIR CONDITIONING&HSheetmetal-531 03/28/2020 Balance Due:$.00 Owner: KENT PECOY&SONS CONSTRUCTION INC #of Fixtures: Applicant: RICHIES AIR CONDITIONING& HEATING INC DigSafe# AT: 39 HIGGINS WAY-LOT 9 UseGroup ConstC lass ISSUED ON: 05-Nov-2019 AMENDED ON: EXPIRES ON: TO PERFORM THE FOLLOWING WORK: HVAC SYSTEM THIS PERMIT MAY BE REVOKED BY THE CITY OF NORTHAMPTON UPON VIOLATION OF ANY OF ITS RULES AND REGULATIONS. Signature: Fee Type: Receipt No: Date Paid: Check No: Amount: Sheetmetal IZEC-2020-001540 04-Nov-19 19090 $50.00 212 Main Street,Phone:(413)587-1240,Fax:(413)587-1272,Email:lhasbrouck(a,)northamptonma.gov GeoTMS*2019 Des Lauriers Municipal Solutions,Inc. Commonwealth of Massachusetts hem 1 Permit Date : OST- Permit# -5h, Estimated Job Cost: F. dab - j P it Fee: $3 50 01,9 Plans Submitted: YES NO �rti���� P ans eviewed: YES NO Business License # want icense # Business Information: Propert Owner/Job Location Information: Name: Name: PC, oy G Street: P� LIO� PCflv AM , Street: 39 0*1 IMS WAY D W9 City/Town: R@r u_)Arn City/Town: kklzoA'O AMf -V130 Telephone: Ll�3 ``�%`1- _I .L-4 q Telephone: LA 1 `l U®l Photo I.D. required/ Copy of Photo I.D. attached: YES NO Building Type: Residential: 1-2 family L/" Multi-family Condo/Townhouses Commercial: Office Retail Industrial Educational Institutional Building Cubic Footage: under 35,000 cu. ft. Grp^ over 35,000 cu. ft. Sheet metal work to be completed: New Work:t/ Renovation: HVAC V Metal Roofing Kitchen Exhaust System Chimney/Vents Provide brief description of work to be done: pv lzxwv R' Pte, Q)f,T N Fro 'FANS ��1�N A10. G'XG1a F�NG'�R �I��C� `t&`f INSURANCE COVERAGE: have a current liability insurance policy or its equivalent which meets the requirements of M.G.L. Ch. 112 Yes ❑ No ❑ If you have checked Yes, indicate the type of coverage by checking the appropriate box below: A liability insurance policy ❑ Other type of indemnity ❑ Bond ❑ OWNER'S INSURANCE WAIVER: I am aware that the licensee does not have the insurance coverage required by Chapter 112 of the Massachusetts General Laws, and that my signature on this permit application waives this requirement. Check One Only Owner ❑ Agent ❑ i Signature of Owner or Owner's Agent By checking this boxb,I hereby certify that all of the details and information I have submitted(or entered) regarding this application are true and accurate to the best of my knowledge and that all sheet metal work and installations performed under the permit issued for this application will be in compliance with all pertinent provision of the Massachusetts Building Code and Chapter 112 of the General Laws. Progress Inspections Date Comments Final Inspection Date Comments Type of License:q! By Master Title ❑ Master-Restricted City/Town ❑Journeyperson Signature of Licensee Permit# ❑Journeyperson-Restricted License Number: rr1— 531 Fee$ ❑ Check at www.mass.gov/dpl Ins ector Signature of Permit Approval .... _._.:..._. This combination qualifies for a Federal Energy i Efficiency Tax Credit when placed in service flu no ILI between Feb 17, 2009 and Dec 31, 2016.. vv vmah rid r a rtif i cafeu c t -m­ a­e , s l AHRI Certified Reference Number: 8742858 Date: 8/2/2017 Product: Split System: Air-Cooled Condensing Unit, Coil with Blower Outdoor Unit Model Number: 4TTR6024J1 Indoor Unit Model Number: 4TXCB003CC3 Furnace Model Number: S9V2B040U3PS Manufacturer: TRANE Trade/Brand name: TRANE Region: All (AK, AL, AR, AZ, CA, CO, CT, DC, DE, FL, GA, HI, ID, IL, IA, IN, KS, KY, LA, MA, MD, ME, MI, MN, MO, MS, MT, NC, ND, NE, NH, NJ, NM, NV, NY, OH, OK, OR, PA, RI, SC, SD, TN, TX, UT, VA, VT, WA, WV, WI,WY, U.S. Territories) Region Note: Central air conditioners manufactured prior to January 1, 2015, are eligible to be installed in all regions until June 30, 2016. Beginning July 1, 2016, central air conditioners can only be installed in region(s) for which they meet the regional efficiency requirement. Series name: XR16 Manufacturer responsible for the rating of this system combination is TRANE Rated as follows in accordance with AHRI Standard 210/240-2008 for Unitary Air-Conditioning and Air-Source Heat Pump Equipment and subject to verification of rating accuracy by AHRI-sponsored, independent,third party testing: Cooling Capacity (Btuh): 23600 EER Rating (Cooling): 13.50 SEER Rating (Cooling): 16.25 IEER Rating (Cooling): Ratings followed by an asterisk(")indicate a voluntary rerate of previously published data,unless accompanied with a WAS,which indicates an involuntary rerate. DISCLAIMER AHRI does not endorse the product(s)listed on this Certificate and makes no representations,warranties or guarantees as to,and assumes no responsibiiity for, the product(s)listed on this Certificate.AHRI expressly disclaims all liability for damages of any kind arising out of the use or performance of the product(s),or the unauthorized alteration of data listed on this Certificate.Certified ratings are valid only for models and configurations listed in the directory at TERMS AND CONDITIONS This Certificate and its contents are proprietary products of AHRI.This Certificate shall only be used for individual,personal and confidential reference purposes.The contents of this Certificate may not,in whole or in part,be reproduced;copied;disseminated; rMs entered into a computer database;or otherwise utilized,in any form or manner or by any means,except for the user's individual, personal and confidential reference. AIR-CONDITIONING.HU. - CERTIFICATE VERIFICATION x REFRIGERATION INS!: The information for the model cited on this certificate can be verified at ^:uw.ahridirectory.r: ,click on" "link we make life betre- and enter the AHRI Certified Reference Number and the date on which the certificate was issued, which is listed above,and the Certificate No.,which is listed at bottom right. ©2014 Air-Conditioning,Heating,and Refrigeration Institute CERTIFICATE NO.: 131461806009743207 d,. fl Load Short Form Job: LOT AN NORTHVIEW wrightsoft Date: J l \CtriS Entire House By: RICHIE RICHIE'S AIR CONDITIONING & HEATING 81 Industrial Lane,Agawam,Ma Project • • For: LOT 2VWNQP2ffJNV%S THE PECOY COMPANY VILLAGE HILL, NORTHAMPTON, MA Design Information Htg Clg Infiltration Outside db (°F) 0 87 Method Simplified Inside db(°F) 70 75 Construction quality Best Design TD (°F) 70 12 Fireplaces 0 Daily range - M Inside humidity (%) 30 50 Moisture difference(gr/Ib) 28 24 HEATING EQUIPMENT COOLING EQUIPMENT Make Make Trade Trade Model Cond AHRI ref Coil AHRI ref Efficiency 80 AFUE Efficiency 0 SEER Heating input 0 MBtuh Sensible cooling 0 Btuh Heating output 0 Btuh Latent cooling 0 Btuh Temperature rise 0 °F Total cooling 0 Btuh Actual air flow 758 cfm Actual air flow 758 cfm Air flow factor 0.029 cfm/Btuh Air flow factor 0.053 cfm/Btuh Static pressure 0 in H2O Static pressure 0 in H2O Space thermostat Load sensible heat ratio 0.95 ROOM NAME Area Htg load Clg load Htg AVF Clg AVF (ft2) (Btuh) (Btuh) (cfm) (cfm) FIRST FLOOR p 1081 13656 7487 399 400 SECOND FLOOR p 830 12281 6845 359 366 Entire House d 1911 25937 14172 758 758 Other equip loads 0 0 Equip. @ 0.92 RSM 13038 Latent cooling 823 TOTALS I 1911 I 25937 I 13861 I 758 I 758 Calculations approved by ACCA to meet all requirements of Manual J 7th Ed. wr{ htsdit 2017-Fety0614:00:45 9 Right-Suite®Universal 2012 12.0.11 RSU17313 Page 1 ..sers\wbean\Desktop\LOADS\RICHIE'S PECOY LOT 20A NORTHVIEW.rup Calc=MR Front Door faces Load ShortJob: LOT!24 NORTHVIEW -�+ wrightsoft Form Date: _- FIRST FLOOR By: RICHIE I �11Cf U RICHIE'S AIR CONDITIONING & HEATING 81 Industrial Lane,Agawam,Ma Project • • For: LOT 2®NOR,1,I4V1F1/V;THE PECOY COMPANY VILLAGE HILL, NORTHAMPTON, MA Design Information Htg Clg Infiltration Outside db (°F) 0 87 Method Simplified Inside db(°F) 70 75 Construction quality Best Design TD (°F) 70 12 Fireplaces 0 Daily range - M Inside humidity(%) 30 50 Moisture difference(gr/Ib) 28 24 HEATING EQUIPMENT COOLING EQUIPMENT Make n/a Make n/a Trade n/a Trade n/a Model n/a Cond n/a AHRI ref n/a Coil n/a AHRI ref n/a Efficiency n/a Efficiency n/a Heating input Sensible cooling 0 Btuh Heating output 0 Btuh Latent cooling 0 Btuh Temperature rise 0 °F Total cooling 0 Btuh Actual air flow 0 cfm Actual air flow 0 cfm Air flow factor 0 cfm/Btuh Air flow factor 0 cfm/Btuh Static pressure 0 in H2O Static pressure 0 in H2O Space thermostat n/a Load sensible heat ratio 0 ROOM NAME Area Htg load Clg load Htg AVF Clg AVF (ftZ) (Btuh) (Btuh) (cfm) (cfm) DEN 272 4413 2719 129 145 FAMILY ROOM 289 3780 2032 110 109 DINING/KITCHEN 520 5463 2737 160 146 FIRST FLOOR p 1081 13656 7487 399 400 Other equip loads 0 0 Equip. @ 0.92 RSM 6888 Latent cooling 466 TOTALS I 1081 I 13656 I 7355 t 399 I 400 Calculations approved by ACCA to meet all requirements of Manual J 7th Ed. WCI IItSQft 2017-Feb-0614:00:45 g Right-Suite®Universal 2012 12.0.11 RSU17313 Page 2 ..sers\wbean\Desktop\LOADS\RICHIE'S PECOY LOT 20A NORTHVIEW_rup Calc=MJ7 Front Door faces Load Short Form Job: LOTrs NORTHVIEW + wri htsoft Date: SECOND FLOOR By: RICHIE RICHIE'S AIR CONDITIONING & HEATING 81 Industrial Lane,Agawam,Ma Project Information For: LOT 2M NOWW!t V, THE PECOY COMPANY VILLAGE HILL, NORTHAMPTON, MA Design Information Htg Clg Infiltration Outside db ('F) 0 87 Method Simplified Inside db('F) 70 75 Construction quality Best Design TD (°F) 70 12 Fireplaces 0 Daily range - M Inside humidity(%) 30 50 Moisture difference(gr/Ib) 28 24 : :�'� i ter'. _ ... .��tT�' +�k:' ,"',�}P�"r' .`?ri'y`" =' i �k"!?`,':� °t�+.�.r. '�>�x�'�Fy-_� .._. _. : E's^ �-xt• ,evc� HEATING EQUIPMENT COOLING EQUIPMENT Make n/a Make n/a Trade n/a Trade n/a Model n/a Cond n/a AHRI ref n/a Coil n/a AHRI ref n/a Efficiency n/a Efficiency n/a Heating input Sensible cooling 0 Btuh Heating output 0 Btuh Latent cooling 0 Btuh Temperature rise 0 °F Total cooling 0 Btuh Actual air flow 0 cfm Actual air flow 0 cfm Air flow factor 0 cfm/Btuh Air flow factor 0 cfm/Btuh Static pressure 0 in H2O Static pressure 0 in H2O Space thermostat n/a Load sensible heat ratio 0 ROOM NAME Area Htg load Clg load Htg AVF Clg AVF (ft2) (Btuh) (Btuh) (cfm) (cfm) BATH 1 170 1408 579 41 31 BED 1 400 5405 2846 158 152 BED/BATH 2 260 5468 3419 160 183 SECOND FLOOR p 830 12281 6845 359 366 Other equip loads 0 0 Equip. @ 0.92 RSM 6297 Latent cooling 357 TOTALS I 830 I 12281 I 6654 I 359 I 366 Calculations approved by ACCA to meet all requirements of Manual J 7th Ed. wri htsoft 2017-Feb-0614:00:45 g Right-Suite®Universal201212.0.11 RSU17313 Page ...sers\wbean\Desktop\LOADS\RICHIE'S PECOY LOT 20A NORTHVIEW.rup Calc=MR Front Doorfaces