24A-250 (4) 201 NORTH ELM ST BP-2020-0545
GIS#: COMMONWEALTH OF MASSACHUSETTS
Map:Block:24A-250 CITY OF NORTHAMPTON
Lot:-001 PERSONS CONTRACTING WITH UNREGISTERED CONTRACTORS
Permit: Building DO NOT HAVE ACCESS TO THE GUARANTY FUND (MGL c.142A)
Category: SOLAR ELECTRIC SYSTEM BUILDING PERMIT
Permit# BP-2020-0545
Project# JS-2020-000943
Est.Cost: $38980.00
Fee:$75.00 PERMISSION IS HEREBY GRANTED TO:
Const.Class: Contractor. License:
Use Group: VALLEY SOLAR LLC 077279
Lot Size(sq.ft.): 7971.48 Owner: RONCO MICHELE
Zoning: URA(100)/ Applicant. VALLEY SOLAR LLC
AT. 201 NORTH ELM ST
Applicant Address: Phone: Insurance:
PO BOX 60627 (413)584-8844 WC
FLORENCEMA01062 ISSUED ON.1012912019 0:00:00
TO PERFORM THE FOLLOWING WORK-40 PANEL ROOF MOUNT SOLAR ARRY - 13.4
KW
POST THIS CARD SO IT IS VISIBLE FROM THE STREET
Inspector of Plumbing Inspector of Wiring D.P.W. Building Inspector
Underground: Service: Meter:
Footings:
Rough: Rough: House# Foundation:
Driveway Final:
Final: Final:
Rough Frame:
Gas: Fire Department Fireplace/Chimney:
Rough: Oil: Insulation:
Final: Smoke: Final:
THIS PERMIT MAY BE REVOKED BY THE CITY OF NORTHAMPTON UPON VIOLATION OF
ANY OF ITS RULES AND REGULATIONS.
Certificate of Occupancy signature:
FeeTvpe: Date Paid: Amount:
Building 10/29/2019 0:00:00 $75.00
212 Main Street, Phone(413)587-1240, Fax:(413)587-1272
Louis Hasbrouck--Building Commissioner
-syr /4f
Department use only
MIZLI r City of Northampton Status of Permit:
r - Building Department Curb Cut/Driveway Permit
zz 212 Main Street Sewer/Septic Availability
Room 100 Water/Well Availabilit3. y
Northampton, MA 01060 Two Sets of Structural Plans
phone 413-587-1240 Fax 413-587-1272 Plot/Site Plans
Other
APPLICATION TO CONSTRUCT,ALTER, REPAIR, RENOVATE OR DEMOL H A R TWO FAMILY D ELLI G
SECTION 1 -SITE INFORMATION Ot - OCT 2 9 2019
Thi sect n to be com Mete ice
1.1 Property Address:
DEPT.OF SUILDINr,INSPECTIONS
Map ItMRTHAMPION,MA 01060
201 N Elm St Northampton,MA 01060 Zone Overlay District
Elm St.District CB District
SECTION 2-PROPERTY OWNERSHIP/AUTHORIZED AGENT
2.1 Owner of Record:
Michele Ronco and Teresa Carillo 201 N Elm St Northampton,MA 01060
Name(Print) Current Mailing Address:
413-314-0108
Telephone
Signature
2.2 Authorized Agent:
Valley Solar LLC PO Box 60627, Florence, MA 01062
Name(Print) Current Mailing Address:
413-584-8844
Signature Telephone
SECTION 3-ESTIMATED CONSTRUCTION COSTS
Item Estimated Cost(Dollars)to be Official Use Only
completed by permit applicant
1. Building (a) Building Permit Fee
2. Electrical (b) Estimated Total Cost of
Construction from 6
3. Plumbing Building Permit Fee
4. Mechanical (HVAC)
5. Fire Protection
6. Total= (1 +2 +3+4+5) Check Number
This Section For Official Use Only
Building Permit Number: Date
Issued:
Signature: bc q/) 7
Building Commissioner/Inspector of Buildings Date
Ihasbrouck @ northamptonma.gov
infovallepolar.solar
EMAIL ADDRESS (REQUIRED; OR CON ACTOR)
SECTION 5-DESCRIPTION OF PROPOSED WORK(check all applicable)
New House ❑ Addition ❑ Replacement Windows Alteration(s) ❑ Roofing ❑
Or Doors 0
Accessory Bldg. ❑ Demolition ❑ New Signs [0] Decks [0 Siding[0] Other[X solar
Brief Description of Proposed
Work: Installation of a 40 panel Solar roof array. ystem Size 13.4kW DC
Alteration of existing bedroom Yes No Adding new bedroom Yes No
Attached Narrative Renovating unfinished basement Yes No
Plans Attached Roll -Sheet
iia.If New house and or addition to existing housing, complete the following:
a. Use of building : One Family Two Family Other
b. Number of rooms in each family unit: Number of Bathrooms
c. Is there a garage attached?
d. Proposed Square footage of new construction. Dimensions
e. Number of stories?
f. Method of heating? Fireplaces or Woodstoves Number of each
g. Energy Conservation Compliance. Masscheck Energy Compliance form attached?
h. Type of construction
i. Is construction within 100 ft.of wetlands? Yes No. Is construction within 100 yr. floodplain Yes No
j. Depth of basement or cellar floor below finished grade
k. Will building conform to the Building and Zoning regulations? Yes No.
I. Septic Tank City Sewer Private well City water Supply
SECTION 7a-OWNER AUTHORIZATION-TO BE COMPLETED WHEN
OWNERS AGENT OR CONTRACTOR APPLIES FOR BUILDING PERMIT
I, Michele Ronco as Owner of the subject
property
hereby authorize Valley Solar LLC
to act on my behalf, in all matters relative to work authorized by this building permit application.
Qj 10/16/2019
Signature of Owner Date
IF-
Valley Solar LLC as Qupw/Authorized
Agent hereby declare that the statements and information on the foregoing application are true and accurate,to the best of my knowledge
and belief.
Signed under the pains and penalties of perjury.
Steven Silverman
Print Name
"0- Qn 10/17/2019
Signature of Owner/Agent Date
SECTION 8-CONSTRUCTION SERVICES
8.1 Licensed Construction Supervisor: Not Applicable ❑
Name of License Holder
License Number
Steven Silverman CS-077279
Address Expiration Date
268 Fomer Road Southampton, MA 01073 6/21/2020
Signature Telephone
,&,.a- 4 413-584-8844
9. Registered Home Improvement Contractor: Not Applicable ❑
Company Name Registration Number
Valley Solar LLC 186338
Address Expiration Date
PO Box 60627, Florence, MA 01062 Telephone 413-584-8844 10/27/20
SECTION 10-WORKERS' COMPENSATION INSURANCE AFFIDAVIT(M.G.L.c. 152, §25C(6))
Workers Compensation Insurance affidavit must be completed and submitted with this application. Failure to provide this affidavit will result
in the denial of the issuance of the building permit.
Signed Affidavit Attached Yes....... No...... ❑
City of Northampton
_.� Massachusetts
A
DEPARTMENT OF BUILDING INSPECTIONS r
212 Main Street a Municipal Building ill b~
Northampton, MA 01060
Debris Disposal Affidavit
In accordance of the provisions of MGL c 40, S54, I acknowledge that as a condition of the building
permit all debris resulting from the construction activity governed by this Building Permit shall be disposed
of in a properly licensed solid waste disposal facility, as defined by MGL c 111, S 150A.
The debris from construction work being performed at:
201 N Elm St
(Please print house number and street name)
Is to be disposed of at:
Valley Recycling. (235 Easthampton Rd, MA 01060)
(Please print name and location of facility)
Or will be disposed of in a dumpster onsite rented or leased from:
Valley Solar. (POB 60627, MA 01062)
(Company Name and Address)
Signature of Permit Applicant or Owner Date
If, for any reason, the debris will not be disposed of as indicated, the Applicant or Owner shall notify the
Building Department as to the location where the debris will be disposed.
The Commonwealth of Massachusetts
„s.
Department of Industrial Accidents
r� t7Jf1ce of Investigations
600 Washington Street
Boston,MA 02111
= www.mass.gov/dia
Workers' Compensation Insurance Affidavit: Builders/Contractors/Electricians/Plumbers
Applicant Information Please Print Legibly
Name tBusiness/Organirttion/Individual): Valley Solar LLC
Address:340 Riverside Drive PO BOX 60627
City/State/Zip:Florence, MA 01062 Phone#: 413-584-8844
Are you an employer?Check the appropriate box: Type of project(required):
1.® I am a employer with 11 4. ❑ I am a general contractor and I
employees(full and/or part-time)." have hired the sub-contractors 6. ❑New construction
2.❑ 1 am a sole proprietor or partner- listed on the attached sheet. 7. ❑Remodeling
ship and have no employees These sub-contractors have 8. Demolition
working an for me in capacity. employees and have workers'
Y p Y. 9. ❑Building addition
[No workers'comp.insurance comp.insurance?
required.] 5. ❑ We are a corporation and its 10.❑Electrical repairs or additions
3.❑ 1 am a homeowner doing all work officers have exercised their 11.❑Plumbing repairs or additions
myself'. [No workers'comp. right of exemption per MG 1, 12.❑Roof repairs
insurance required.]t e. 152,§1(4),and we have no
employees.[No workers' 13.®Other Solar
comp.insurance required.]
*Any applicant that cheeks box N 1 must also fill out these tion below showing their workers'compensation policy information.
t 1 tomcowners who submit this affidavit indicating they are doing all work and then hire outside contractor must submit a new an'idavit indicating such.
:Contractors that check this box must attached an additional sheet showing(be name of the sub-contractors and state whether or not those entities have
employees. If the sub-contractors have employees,Ilicy must provide their worker'comp.policy number.
I ani an employer that is providing workers'compensation insurance for my employees. Below is the policy and job site
information.
Insurance Company Name:_Liberty MUtUaI
Policy#or Selr ins.Li,.#:WC531 S620647019 Expiration Date: 2/1/2020
Job Site Address: 201 N Elm St city/state/zip:Northampton, MA 01060
Attach a copy of the workers'compensation policy declaration page(slowing the policy number and expiration date).
Failure to secure coverage as required under Section 25A of MGL c. 152 can lead to the imposition of criminal penalties of a
fine up to$1,500.00 and/or one-year imprisonment,as well as civil penalties in the form of a STOP WORK ORDER and a fine
of up to$250.00 a day against the violator. Be advised that a copy of this statement may be forwarded to the Office of
Investigations of the DIA t'or insurance coverage verification.
1 do hereby certify unde t alas and pe !ties of per' a information provided above is true and correct.
Signature: Date: 0
Phone#: 413-584-8844 _
Official use on11. Do not write lit this area,to be completed by city or town official
City or Town: Permit/License#
Issuing Authority(circle one):
1.Board of Health 2. Building Department 3.City/Town Clerk d. Electrical Inspector 5.Plumbing Inspector
6.Other
Contact Person: 1'hunc th
Penn FUS10h1 152 S. Broad
4IE n g I try ® e f 1 n Q Lansdale, 1944466
(215)366 1-8040
October 25, 2019
Valley Solar
340 Riverside Dr
Northampton, MA 01062
RE: Ronco Residence
201 N Elm St, Northampton,MA 01060
Client Project#:201 RONC
PFE Project#: 194421
On behalf of Valley Solar, Penn Fusion Engineering LLC (PFE) performed a structural analysis of the roof at the above
referenced location. The purpose of our analysis was to determine if the existing roof system is structurally sufficient to
support the new photovoltaic moudles in addition to the code required design loads. Our analysis is based on the information
provided by Valley Solar and is isolated only to the areas where the modules are intended to be placed.
System Specifications:
Total System Size: 13.4 kW/DC
Panel Specs: (40)LG Solar- LG335NIC-A5
Inverter Specs: (40)Enphase - IQ7+
Racking System: SNAPNRACK- UR
The modules are to be located on the following roof plane:
Mounting Rafter Rafter Horizontal Collar Collar Tie Sheathing Shingle Number of Ceiling
Plane Size Spacing Span Ties Spacing Type Shingle Layers Profile
1 2x6 16" 1 3ft. Oin. N/A 0" CDX 112" Asphalt 1 Flat
Shingles
The roof design has been analyzed in accordance with the 2015 International Residential Code and Massachusettes
Amendments 9th Edition with design loads as follows:
Ground Snow(Pg): 40 psf
Wind Speed (V): 120 mph
Mounting Plane 1
The calculations for these structural members are attached. It has been determined by this office that the rafters, as specified
above, exceed the allowable span for the total design loading. Attached are repair details that, when installed,will render the
roof design structurally adequate to support the new PV modules in addition to the code required design loading.
Attach the module rail brackets to the roof with 5/16" lag bolts at 48 on center maximum with staggered penetration such
that load is distributed evenly among roof members. Provide a minimum of 2" of penetration into the wood members.
This office has determined that the installation of the PV System as specified above will meet the structural requirements of
the 2015 International Residential Code with Massachusettes Amendments 9th Edition and ASCE7-10 when installed in
accordance with the manufacture's instructions.
If you have any questions regarding this analysis, please feel free to contact us.
�l*1t Of 1.1",F9
Best Regards, 4i` 01
Penn Fusion Engineering LLC
ti a►D�KE►t DOs1E"UC m
LEONE
NO.53G4.k
Andrew D. Leone, P.E. Ts
Principal ISIE
SS� ,AL
Penn FUSION 152 S. Broad
E n � 1 n e s r i n d Lansdale, PA 1944646
(267)640-2758
Client Name: Valley Solar
PFE Project Number: 194421
Client Project Number: 201 RONC
Project: Ronco Residence
Address: 201 N Elm St
Northampton, MA 01060
Description: Mounting Plane 1
Calculations By: ADL
Date: October 25, 2019
Roof Construction
2x6 Rafters at 16"on center
A= 8.25 int
Ix= 20.8 in
Sx= 7.56 in
Wood Species= Doug-Fir Larch #2
Fb= 900 psi
Fv= 180 psi
E= 1600000 psi
Roof Slope= 22 °
Rafter Span= 12.96 ft
Ceiling Attached to Rafters?: No
Design Criteria
Ground Snow(P9): 40 psf
Design Wind Speed: 120 mph
Live Load: 20 psf
Dead Load: 4.39 psf
PV Modules: 3.24 psf
Wind Calculations
Directionality Factor(Kd): 0.85
Topographic Factor(KZt): 1
Velocity Pressure Exposure 0 7
Coefficient(KZ):
Importance Factor(1): 1
Velocity Pressure(q,): 21.93 psf
Tributary Square Footage on 10.83 ftz
Component:
Component Roof Pressures: 14.76 / -60.52 psf
Snow Load Calculations
Exposure Factor(Ce): 1
Thermal Factor(Ct): 1
Importance Factor(1): 1
Flat Roof Snow Loads(Pf): 35 psf
Roof Slope Factor(CS): 1
Sloped Snow Loads(PS): 35 psf
Unbalanced Snow Load: 40 psf
Member Calculations
Bending
Md: 1333.82 ft*Ib
fb: 2116.47 psi
Load Duration Factor(Cd): 1.15
Stability Factor(CO: 1
Wet Service Factor(CM): 1
Temperature Factor(CT): 1
Size Factor(CO: 1.3
Flat Use Factor(Cf„): 1
Incising Factor(C): 1
Repetitive Member Factor(Cr): 1.15
Fb: 900 psi
Fib: 1547.33 psi 2116.47>1 547.33 No Good in Bending
Shear
Vd: 411.6 Ib
f,,: 74.84 psi
Load Duration Factor(Cd): 1.15
Wet Service Factor(CM): 1
Temperature Factor(CT): 1
Size Factor(CO: 1.3
Flat Use Factor(Cf„): 1
Incising Factor(Cl): 1
F,,: 180 psi
F'„): 207 psi 74.84<=207 OK in Shear
Deflection
Live Load Deflection 00: 1.02 in L/1 53 No Good in Live
Load Deflection
Total Load Deflection (OT): 1.21 in L/128 OK in Total Load
Deflection
Uplift Calculation
Tributary Square Footage on 10.83 ftz
Component:
Uplift Pressure: -60.52 psf
Uplift per Lag: -655.63 lbs
Lag Screw Diameter: 5/16 in
Allowable Withdrawal per Inch: 490.99 lbs/in
Minimal Screw Penetration: 1.34 in
Install 5/16"diameter lag screws @ 48 on center with
minimum penetration of 2" into rafter.
0 Penn FUSION 152 S. Broad
E n G l n e e r l n Q Lansdale, PA 1944466
(267)640-2758
Client Name: Valley Solar
PFE Project Number: 194421
Client Project Number: 201 RONC
Project: Ronco Residence
Address: 201 N Elm St
Northampton, MA 01060
Description: Mounting Plane I
Calculations By: ADL
Date: October 25, 2 01 9
--EXISTING RAFTER
NEW SISTERED RAFTER. SEE
-
'--SCHEDULE BELO'N FOR SIZE
AND NAILING REQUIREMENTS
New Sistered Rafter Size: 2x6x8' Doug-Fir Larch #2 or better*
Nailing Requirements: (2) l Od Nails C@ 12"on center with (3)additional l Od Nails at each end
I Od = .12" shank diameter x 3" long minimum
Note: Apply repair to each rafter under PV system
*Suitable Alternate Species:
-Spruce-Pine-Fir#2 or#1
-Southern-Yellow-Pine#2 or#1
PLAN LEGEND a
ROOF ARRAY
s
LAYOUT: EAST ROOF 8X2 WEST ROOF 8X3
(40)LG335N1K-A5 SOLAR PV PANELS � �w
(40)ENPHASE IQ7 MICRO-INVERTERSJi
w ow
•"' ► _ + SnapNRack ULTRA RAIL RACKING SYSTEM s` v
INTERNAL WALL OF HOUSE cr z -�
m tet' m"oU
SOLAR PV COMBINER BOX(N) 6 E10
x AC DISCONNECT(N) z
MAIN ELECTRICAL PANEL(E) co
N
�O
t1Od �� EXTERNAL WALL OF HOUSE °a
$ C21261X39:1111AC DISCONNECT(N) ~t: ?
—cot
Opp ext, • ❑ MA SMART GENERATION METER(N)
UTILITY METER(E)
"Wow Z
W
m _
a N
= r movi�
��y �r H•
s
ti
31
`gyy r
i� Jm
t
a '
aS UTILITY INFO: Utility Company National Grid Utility Customer of Kecora Michele Ronco utility Acct#63206-95105
C4
e
a
a
o O
E a
ELM ST o t
M:13379 Pg.azo
Y Z o
y o
05 NORTH
ELM ST -
9 ELM ST
} ELM ST as:rssrw�wawr9P:taa N
0
>n (I of 2) _�m Premiss: Naro,�w:oaJaelOro ta:sr ra w
2M NORTH QUITCLAIM DEED <o 2
ELM ST 201 NORTH ELM ST W w
a NORTHAMPTON —_ N
KNOW ALL PERSONS BY THESE PRESENTS,that I,JOSEPH O.HEBERT,111,of 27
3 Foxglove Lane,Amherst,Hampshire County,Massachusetts
s Owner HEBERT MARGUERITE F&
F r
27 FOXGLOVE LANE for consideration paid, and in full consideration of THREE HUNDRED THIRTY-NINE
1t AAAwERST Pv1A O100Z 'THOUSAND AND 00,100(5339,000.00)DOLLARS W
201 NORTH z
g ELM ST 8u#din9 Value $155 500 grants to a married couple,both of 73 Bridge J
m Land VBlIe. $1'J6 OOd Street,Northampton,Hampshire County,Massachusetts,as tenants by the entirety r
O O
'?ther Value $O 'ILGRIM DI with QUITCLAIM COVENANTS J
a
,. Total Value: $311.500 The land in Northampton. Hampshire County, Massachusetts, with the buildings thereon,
8 I)RTH f-r situated on the easterly side of North Elm Street and further bounded and described as follows:
a£ A ST 197 NORTH
ELM ST Assessment data trom Fy 2014
�
°z Cn SEE EXHIBIT"A-ATTACHED HERETO AND INCORPORATED HEREIN
r" Lor Size 0.18 Acres 2 '
o E n
Last Sale Price so
pLast Sale Date. Being the same premises conveyed to the grantor herein by deed of Marguerite F.Hebert to >z
Use Code 101 Marguerite F.Hebert and Joseph O.Hebert,III dated January 31,2000,and recorded in the ¢ —>
Hampshire County Registry of Deeds in Bonk 5932,Page 35.Marguerite F.Hebert is deceased. g
e 105 NORTH "ear Butt: 195E See Estate Tax Affidavit recorded in the Hampshire Countv Registry of Deeds in Book 11939
a ELM ST -Dom to o
�C
p 1 �
an(l., rim nri\/P � �
MOD 1 16 MOD MOD MOD UTILITY INFO: COMMUNICATIONS:
a LL Utility Company National Grid Wifi or cat5 to Envoy TBD
O 2 MICRO Utility Customer of Record Michele Ronco
WW IN BRANCH 4 Utility Acct#63206-95105INVERTERS
CIRCUIT Meter Number 64316062 S
AC AC AC 7B Address 201 N Elm St Northampton,MA 01060 CONDUCTOR/OCPD CALCULATIONS:
til DC . . . . . . . . DC DC DC NEC 210.19(A)(1)(a))Inverter 107 Max Output
E =1.OA x 40=40A x 1.25=50A e
$ U
a (1)#6 CU THHN (2)#12CUTHAN-2. 1212 RX EE
{ EGC G Cade #B Cu BARE
Efip LINE on the top and the LOAD on the $r gip
>; . . . . . . . bottom side of the MA SMART Meter ir Z
MOD 12 MOD MOD MOD AC Isolation Device between I ~o
Company meter&DER 1 E
MICRO AC Isolation Device AC Isolation Device
INVERTERS
IN BRANCH ! SMART Meier o
CIRCUIT 4 V5# 3 9 cc �
O 5 1 2 6 4 5 8 8 9 �o
J Box
AC_ AC AC AC
DC DC DC DC �� fj Main Panel 10 10 1 1
� AC Disco CB Dleco w w
ta�r�_.
,�2 kWh /� kwn
M To/
JI MICRO 6r3 sER From
INVERTERS (31 IN MC RX
4 AC Combiner BozSER Utility
a$ IN BRANCH
314,0- is,
aro situ
Isl°"" 6/3 SER 6/3 SER icefiCIRCUITala•sleennewQ
AC AC AC (4),#12 CU THHN PRooumlaN cTs — c O
(1)#6 CU THHN J
DC DC DC DC N w•EMT _
$a �
H
U
p g EQUIPMENT SCHEDULE O Inverter TND Settincs: LABELING SCHEDULE W
1 RACKINGUltra-Rail Sna NRack Roof Mount S Inverter TRIP settings are set in the Inverter per the ISO NE SRD and ESa 756 1 WARNING!PHOTOVOLTAIC POWER SOURCE
( ) P System section 7.6.11. 2 SOLAR PV AC COMBINER BOX i $
m c
2 MODULE(LG335N1 K-V5)40x solar PV panels.Max output DEVICE DEFAULT DEFAULT Pickups and E$IR
41.1 V/10.31A PICKUP SETTING CLEARING TIME Clearing Times 3 PV SYSTEM AC DISCONNECT Rated AC Output Current:4 8 E
pp AC Nominal Operating Voltage:240V AC $
3 INVERTER(107-60-2-US)40x Enphase 107.DC/AC (simplified defaults (seconds) Adhero to
g microinverter.Max output 240VA1 1.OA from section Required 4 RAPID SHUTDOWN SHUTDOWN SWITCH FOR SOLAR v
4 J-BOX(SD-0786-41)Flashed Soladeck AC/DC Rated pass- 7.6.111 Dersults(rest SYSTEM(reflective) A
thru enclosure.1 per roof
No): 5 WARNING!ELECTRICAL SHOCK HAZARD TERMINALS ON
Under Frequency 58.5 Hz 0.18 res BOTH LINE AND LOAD SIDES MAYBE ENERGIZED IN THE o g
a 5 AC COMBINER(X-IQ-AMI-240-3)3x 20A Breaker/branch. m
(e1u) OPEN POSITION
1 x 1 OA breaker for 10 Envoy Gateway with production RGM 1'3O
Under Frequency 58.5 Hz 300 res 6 UTILITY GENERATION METER 0.
6 AC DISCONNECT(DG222URB)60A240VAC(adjacent to (81U)
utility meter 7 WARNING BUSBAR IS ENERGIZED FROM 2 SOURCES
a tY ) Over Frequency 61.2 Hz 300 yes UTILITY GRID AND PHOTOVOLTAIC SYSTEM m
7 GENERATION METER(Milbank U5934)Socket installed for (810) >
s MA SMART Generation meter Over F 8 WARNING!INVERTER OUTPUT CONNECTION DO NOT
Utility's Frequency 82.0 Hz o.18 res OVERCURRENT DEVICE
THIS
8 AC DISCONNECT(BR24L70SP)70A load center.2P SOA (810) RELOCATEiM
CB system OCPD Under Votage(27) So%af Nominal 1.1 yes 9 SOLAR PV IX
a 110X of Nominal 2 Over Voltage 10 WARNING!UTILITY METER ENERGIZED BY 2 SOURCES K
89 SERVICE PANEL 200A MAIN,200A BUS.Taps line side of Under Voltagege(27) 88h of Nominal 2 res 3& 11 UTILITY SERVICE METER
main breaker (59) vs
10 UTILITY METER 120/24OV,1PH,3W Over voltage(5s) 120!4 of Nominal 0.16 Yss
jy THIS ELECTRICAL DRAWING 13 A PROPOSED DESIGN.THE ELECTRICIAN 15 AT LIBERTY TO ADJUST DURRIO THE BUIID AND AMENDMENTS WILL BE REFLECTED N THE AS UILT dAOitMt.
LG N ONO2 BI
4
LG335N1 K-V5
335W
The LG NeON°2 is LG`s best selling solar module,and is one of the most
powerful and versatile modules on the market today.Featuring LG's Celto
Technology,the LG NeON°2 increases power output.New updates include
an extended performance warranty from 86%to 90.08%to give customers
higher performance and reliability.
D"E ce us C E ILi ` 51J
®Made in aiiiiiiiiiiiii
USAF
t•
Features
Enhanced Performance Warranty Enhanced Product Warranty
2 5-rs
LG NeONO 2 Black has an enhanced LG has extended the warranty of the NeON°2
performance warranty.After 25 years, Black to 25 years including labor,which is top
LG NeON°2 Black is guaranteed at level in the industry.
least 90.08%of initial performance.
Better Performance on a Sunny Day + Roof Aesthetics
® LG NeON°2 Black now performs better LG NeON°2 Black has been designed with
-= on sunny days,thanks to its improved aesthetics in mind using thinner wires that
temperature coefficient. appear all black at a distance.LG NeON°2
Black can increase the value of a property
with its modern design.
When you go solar, ask for the brand you can trust: LG Solar
About LG Electronics
LG Electronics is a global leader m electronic products in the clean energy markets by offering sdar PV panels and energy storage systems.The company firs'embarked an a solar �� Solar
energy source research program,n 1985,supported by LG Group's vast ezpenence in the sena-cunductor,LCD,chemistry and materials industnes.In 2010,LG Solar successfully
released its first MormXe series to the market,which is now available m 32 countries The NeONe(prenous MonoXe NeON),NeONe2,NoONe7 Biracial won the"Intersolar
AWARD"in 2013,2015 and 2016,which demonstrates LG's leadership and mnovation in the solar industry.
LG NeON'2 Brack
LG335N 1 K-V5
General Data Electrical Properties(STC')
Cell ProperCks(Mftrniel/I)pej. Monocrystaflme/N-type Model LG335N114V5
Cell Maker -
LG Maxlmrrnpower(Pmax) [W)I 335
Cell Configuration 60 Cells(6 x 10) MPP Voltage(Vmpp) -[V] ; 34.5
._.J.:..:_.T _..
Numberof Bushart .. 12EA MPP Grrert _.-
_-..__ (I'^Pp) [A] 9.72
Module Dimensbns(LxWx.H) 1,686mmx1,016mmx40mm Open Circuit Voltage(Voc 5%) (V] 41.1
Weight 17.1 kg Short Circuit Current(Isc 5%) [A] 1031
Glass(Material) .Tempered Glass with ARCoatingModule Efficiency
Backsheet(Color) Black Power Tolerance %]i 0 __---_—_
Frame(Material) : Anodized Alumxxum -STC(Standard Test Condition)hradiarxe 1000 Wm',Cee temperature 258C,AM 15,Measure Tolerance.t3%
Junction Box(Protection Degree) IP 68 with 3 Bypass Diodes
Cables(Length) 1,000mmx 2EA Operating Conditions
Connector(Type/Maker) MC 4/MC Operating Temperature ['C] -40-+90
Maximum System Voltage- (V] 1,000(ULI 1000QEC)
Maximum Series Fuse Rating (A] 20
Certifications and Warranty
Mechanical Test Load(Front) [Palpsf] 5,400/113
IEC61215-1/-1-1/2:2016.IEC 61730-12:2016, -- _
UL 1703 MethanicalTest Load(Rear) [Palpsf] 4,000/84
Certifiicxms --__. _.--
150 9001,ISO 14001,ISO 50001 'Manufacturer Declaration according to IEC 61215.2005
Mechanical Test Loads 5,400 Pa/4,000 Pa based on IEC 61215-22016
OHSAS 18001 (Test Load-Design Load x Safety Factor(1.5))
Salt Mist Corrosion Test IEC 62701:2012 Severity 6
Ammonia Corrosion Test IEC 6271&2013 Packaging Configuration
Fire Rating Class C(UL 790) Number of Modules per Pallet _ -[EA] _-- -- 25
Sober M, Ir Product Warranty 25 Years Number of Modules per 40ft HQ Container [EA] 650
Solar Module Output Warranty Linear Warranty* Packaging Box Dimensions(L x W x H) [mm] 1,750 x 1,120 x 1,221
Improved 1 st year 98%,from 2-24th year.0.33"w aper 25th year:90.08% Packaging Box Gross Weight [kq] 464
Temperature Characteristics Dimensions(mm/inch)
NMOT` [°C1 42 3 3
Pmax [%/°C] -0.36
Voc [%/°C] -0.27.
Isc
[ C] 0.03 [une:mc✓rxn
)
•NMOT(Nominal Module Operating Temperature).kradimce 800 W/m2,Ambient temperature 20 Y,
Wind speed 1 m/s,Spectrum AM 1.5 40. •sr
erov.fl.o xol�
Ir xl t
Electrical Properties(NMOT)
Model
LG335N1K-VS
Mwdmlmpovver(Pm§4 [W) 250
MPPVoltage(Vngp) [V) ...32.3
MPPcirrent(kw) [A] 7.75
Open Girder lam)-- IV] 38.6
Short Circuit Current(6e) [A] 8.29
om i IN Curves t
1201 1�
,0oow
10.0 =
am
¢ 3A
60
6o wr
u
4.0 VON - -
2,0 200w
i Q
Qo `
ao I. M
00 10.0 20.0 300 40,0 'Voltage(V)
® LG Solar
Bu i mss Inc. Product specifications are subject to change without notice. ❑M
LG Sdar Business D viscon LG335N1K-V5_AUS.pdf
2000 Millbrook Drive '
Lincolnshire,IL.60069 •{rr
r
Life's Good www.lg-solarcom 0 2019 LG Electronics.All rights reserved.
Enphase The high-powered smart grid-ready
Enphase IQ 7 IAicro' and Enphase IQ 7i- Micro''
I 7 and 1 7+ dramatically simplify the installation process while
achieving the highest system efficiency.
Part of the Enphase IQ System,the IQ 7 and
IQ 7+ Microinverters integrate with the Enphase
IQ Envoy'", Enphase IQ Battery'", and the Enphase
Enlighten'" monitoring and analysis software.
IQ Series Microinverters extend the reliability
standards set forth by previous generations and
undergo over a million hours of power-on testing,
enabling Enphase to provide an industry-leading
warranty of up to 25 years.
Easy to Install
Lightweight and simple
Faster installation with improved,lighter two-wire cabling
Built-in rapid shutdown compliant(NEC 2014&2017)
Productive and Reliable
Optimized for high powered 60-cell and 72-cell*modules
More than a million hours of testing
Class II double-insulated enclosure
UL listed
rz+
- " Smart Grid Ready
*� d41.
Complies with advanced grid support,voltage and
frequency ride-through requirements
Remotely updates to respond to changing
grid requirements
Configurable for varying grid profiles
Meets CA Rule 21 (UL 1741-SA)
'The IQ 7+Micro is required to support 72-cell modules.
U�
® !::�v ENPHASE.
To learn more about Enphase offerings,visit enphase.com ��<�"
Enphase IQ 7 and IQ 7+ Microinverters
INPUT DATA(DC) I07-60-2-US IQ7PLUS-72-2-US
Commonly used module pairings' 235W-350W+ 235W-440W+
Module compatibility 60-cell PV modules only 60-cell and 72-cell PV modules
Maximum input DC voltage 48 V 60 V
Peak power tracking voltage 27V-37V 27 V-45 V
Operating range 16 V-48 V 16 V-60 V
Min/Max start voltage 22V/48V 22 V/60 V
Max DC short circuit current(module Isc) 15A 15A
Overvoltage class DC port 11 II
DC port backfeed current 0 A 0 A
PV array configuration 1 x 1 ungrounded array;No additional DC side protection required;
AC side protection requires max 20A per branch circuit
OUTPUT DATA(AC) IQ 7 Microinverter IQ 7+Microinverter
Peak output power 250 VA 295 VA
Maximum continuous output power 240 VA 290 VA
Nominal(L-L)voltage/range2 240 V/ 208V/ 240V/ 208 V/
211-264 V 183-229 V 211-264 V 183-229 V
Maximum continuous output current 1.0 A(240 V) 1.15 A(208 V) 1.21 A(240 V) 1.39 A(208 V)
Nominal frequency 60 Hz 60 Hz
Extended frequency range 47-68 Hz 47-68 Hz
AC short circuit fault current over 3 cycles 5.8 Arms 5.8 Arms
Maximum units per 20 A(L-L)branch circuit3 16(240 VAC) 13(208 VAC) 13(240 VAC) 11 (208 VAC)
Overvoltage class AC port III III
AC port backfeed current 0 A 0 A
Power factor setting 1.0 1.0
Power factor(adjustable) 0.85 leading...0.85 lagging 0.85 leading...0.85 lagging
EFFICIENCY @240 V @208 V @240 V @208 V
Peak efficiency97.6%
9 7.6% 47.5% 47.3%
CEC weighted efficiency 97.0% 97.0% 97.0% 97.0%
MECHANICAL DATA
Ambient temperature range -40°C to+65°C
Relative humidity range 4%to 100%(condensing)
Connector type(IQ7-60-2-US&IQ7PLUS-72-2-US) MC4(or Amphenol H4 UTX with additional Q-DCC-5 adapter)
Dimensions(WxHxD) 212 mm x 175 mm x 30.2 mm(without bracket)
Weight 1.08 kg(2.38 lbs)
Cooling Natural convection-No fans
Approved for wet locations Yes
Pollution degree PD3
Enclosure Class II double-insulated,corrosion resistant polymeric enclosure
Environmental category/UV exposure rating NEMA Type 6/outdoor
FEATURES
Communication Power Line Communication(PLC)
Monitoring Enlighten Manager and MyEnlighten monitoring options.
Both options require installation of an Enphase IQ Envoy.
Disconnecting means The AC and DC connectors have been evaluated and approved by UL for use as the load-break
disconnect required by NEC 690,
Compliance CA Rule 21 (UL 1741-SA)
UL 62109-1,UL1741/IEEE1547,FCC Part 15 Class B, ICES-0003 Class B,
CAN/CSA-C22.2 NO.107.1-01
This product is UL Listed as PV Rapid Shut Down Equipment and conforms with NEC-2014 and
NEC-2017 section 690.12 and C22.1-2015 Rule 64-218 Rapid Shutdown of PV Systems,for AC
and DC conductors,when installed according manufacturer's instructions.
1.No enforced DC/AC ratio.See the compatibility calculator at gd le-compatibility.
2.Nominal voltage range can be extended beyond nominal if required by the utility.
3.Limits may vary.Refer to local requirements to define the number of microinverters per branch in your area.
To learn more about Enphase offerings,visit enphase.com tom/ E l" PHASE.
,c12019 Enphase Energy All rights reserved.All trademarks or brands used are the property of Enphase Energy,Inc.
2019-3-26
SNAPNRACK UR-40 RAIL SHOWN SPLICED REVISION:
TOGETHER WITH THE SNAPNRACK ULTRAa 11012017 NEW DETAIL HA
RAIL SPLICE. 2"MAX 1/s" Y4"RAIL GAP - —
2"MIN FOR THERMAL EXPANSION -
TORQUE SPECIFICATIONS: AT SPLICES _
'/100 NUTS&BOLTS,10-16 FT-LBS
CENTER SPLICE BETWEEN THE TWO
BONDING CLIPS AS SHOWN IN"SPLICE
ALIGNMENT LIMITS"VIEW
oow
RAIL EDGE MUST NOT PASS— SPLICE ALIGNMENT LIMITS
THE CLIP EDGE,AS SHOWN.
SNAPNRACK UR-40 RAIL,
p TYP.
SNAPNRACK BONDING CLIP,TYPE 2
FOR BONDING ACROSS RAILS
V16"O-18 BOLT,S.S.
SNAPNRACK ULTRA SPLICE ASSEMBLY,
CENTER ON RAIL GAP t 1"
SNAPNRACK ULTRA SNAPNRACK ULTRA
SPLICE,THRU
SPLICE,TAPPED
Sunrun South LLC DESIGNER: M.Affentranger SCALE: DNS PART NUMBER: DESCRIPTION: REV
9:
^�°°°°°°F ^° °°�°� DRAFTER: M.Affentranger UR40 D05 UR 40 ULTRA SPLICE DETAILS(a To
DATE: 11/7/2017
• �°"'° "°°' APPROVED BY: G.MCPheeters
SNAPNRACK UR-40 RACKING SYSTEM REVISION:
SHOWN MOUNTED ON ULTRA FOOT WITH SNAPNRACK q _111M/2017 NEW DETAIL Mn
UNIVERSAL END CLAMPS.FOR TILE MID CLAMP, _
NP'
ROOFING USE SNAPNRACK TILE "RAIL END OVERHANG" --
REPLACEMENT,UNIVERSAL TILE HOOK,OR NOT TO EXCEED 34%OF -- — ----
FLAT TILE HOOK SYSTEMS. ACCEPTABLE RAIL SPAN
STANDARD LAG SCREW SPEC ASSUMES SNAPNRACK UNIVERSAL END
CLAMP ASSEMBLY,TYP.
i6"0 LAG SCREW WITH 2t/z"MIN.
EMBEDMENT INTO STRUCTURAL MEMBER. /
TOROUE SPECIFICATIONS: /
s SNAPNRACK UR-40 RAIL,TYP. (MODULE H ROOF ATTACHMENT
/s"P1 NUTS&BOLTS,10-16 FT-LBS (MODULE HIDDEN FOR CLARITY)
RAILS CAN BE MOUNTED ON EITHER SIDE
OF ULTRA FOOT;UPSLOPE OR
DOWNSLOPE.
FOR UNEVEN ROOF SURFACES,UTILIZE DETAIL A
THE SNAPNRACK LEVELER EXTENSION
LEVELING SPACER.SEE DETAIL(S) "RAIL SPAN"IS DEFINED AS
"UR40-DO1,""UR40-DO8,""UR40-D09,"& DISTANCE BETWEEN
"UR40-D10,"FOR DETAILS AND \ ROOF ATTACHMENTS
LIMITATIONS.
i
"STRUCTURAL MEMBER(S)"
MAY REFER TO RAFTERS,PURLINS,
BEAMS,OR OTHER STRUCTURAL,
LOAD-CARRYING MEMBERS
r
SNAPNRACK MID CLAMP,TYP;
CLAMP ASSEMBLY SHALL BE
SELECTED TO MATCH PV MODULE
"MODULE OVERHANG"
NOT TO EXCEED 25%OF MODULE
LENGTH OR MODULE MANUFACTURERS
RECOMMENDATIONS
SNAPNRACK ROOF ATTACHMENT
LAG SCREWED INTO STRUCTURAL MEMBER.
NO FLASHING SHOWN FOR CLARITY.
r _ Sunrun South LLC DESIGNER: M.Affentranger SCALE: DNS PART NUMBER: DESCRIPTION: REV
s�1,f I'7 '� ses nuns-r srx�,=or"-1*s,"rnnrci c�w�n us• A
��e � /5 =�"E•r���•"•.•...yam= DRAFTER: M.Affentranger UR40-DO6 UR-40 TYPICAL LAYOUT H
, N,"otmw �" DATE: 11/30/2017
" " °° TME APPROVED BY: G.McPheeters