Loading...
36-222 (7) 85 WINTERBERRY LN BP-2020-0352 GIs#: COMMONWEALTH OF MASSACHUSETTS Map:Block: 36-222 CITY OF NORTHAMPTON Lot: -001 PERSONS CONTRACTING WITH UNREGISTERED CONTRACTORS Permit: Buildinq DO NOT HAVE ACCESS TO THE GUARANTY FUND (MGL c.142A) Category: SOLAR ELECTRIC SYSTEM BUILDING PERMIT Permit# BP-2020-0352 Proiect# JS-2020-000586 Est. Cost: $50795.00 Fee: $75.00 PERMISSION IS HEREBY GRANTED TO: Const. Class: Contractor: License: Use Group: ALL ENERGY SOLAR INC 109847 Lot Size(sq. ft.): 169884.00 Owner: SMITH ZACHARY Zoning: Applicant: ALL ENERGY SOLAR INC AT. 85 WINTERBERRY LN Applicant Address: Phone: Insurance: 159 FRONT ST (413) 461-7621 () WC CHICOPEEMA01013 ISSUED ON.9/18/2019 0:00:00 TO PERFORM THE FOLLOWING WORK.ROOF MOUNTED SOLAR; 48 PANEL 15.360 KW POST THIS CARD SO IT IS VISIBLE FROM THE STREET Inspector of Plumbing Inspector of Wiring D.P.W. Building Inspector Underground: Service: Meter: Footings: Rough: Rough: House# Foundation: Driveway Final: Final: Final: Rough Frame: Gas: Fire Department Fireplace/Chimney: Rough: Oil: Insulation: Final: Smoke: Final: THIS PERMIT MAY BE REVOKED BY THE CITY OF NORTHAMPTON UPON VIOLATION OF ANY OF ITS RULES AND REGULATIONS. Certificate of Occupancy Signature: FeeType: Date Paid: Amount: Building 9/18/2019 0:00:00 $75.00 212 Main Street,Phone(413)587-1240,Fax: (413)587-1272 Louis Hasbrouck—Building Commissioner The Commonwealth of Massachusetts Board of Building Regulations and Stand—IrR E C E I LIT Massachusetts State Building Code,780 C Building Permit Application To Construct,Repair,Renova Or emolish a Revised r 20 One-or Two-Family Dwelling SEP This Section For Official Use Only Building Permit Number: Date Applied: NORTHAMPTON,MA 01060 / o Builng Official(Print Name) Sikniture Date SECTION 1: SITE INFORMATION 1.1 Property Address: 1.2 Assessors Map&Parcel Numbers 85 Winterberry Lane, Northampton, MA 01062 36 222-001 1.1 a Is this an accepted street?yeses no Map Number Parcel Number 1.3 Zoning Information: 1.4 Property Dimensions: 3.90 acres Zoning District Proposed Use Lot Area(sq ft) Frontage(ft) 1.5 Building Setbacks(ft) Front Yard Side Yards Rear Yard Required Provided Required Provided Required Provided 1.6 Water Supply:(M.G.L c.40,§54) 1.7 Flood Zone Information: 1.8 Sewage Disposal System: Public❑ Private❑ Zone: _ Outside Flood Zone? Municipal❑ On site disposal system ❑ Check if yes❑ SECTION 2: PROPERTY OWNERSHIP' 2.1 Owner'of Record: Zach Smith Northampton, MA 01062 Name(Print) City.State.ZIP 85 Winterberry Lane (978) 621-4113 zrs012@gmail.com No.and Street Telephone Email Address SECTION 3: DESCRIPTION OF PROPOSED WORK'(check all that apply) New Construction❑ Existing Building❑ Owner-Occupied ❑ Repairs(s) ❑ Alteration(s) ❑ Addition ❑ Demolition ❑ Accessory Bldg.❑ Number of Units Other 0 Specify:SOLAR PV Brief Description of Proposed Work': Installation of 48(320W)solar panels flush-mounted on roof of the property. Total system size(DC): 15.360 kW SECTION 4:ESTIMATED CONSTRUCTION COSTS Item Estimated Costs: Official Use Only Labor and Materials 1.Building $40,636 1. Building Permit Fee:$ Indicate how fee is determined: ❑Standard City/Town Application Fee 2.Electrical $10,159 ❑Total Project Costa(Item 6)x multiplier x 3.Plumbing $ 2. Other Fees: $ 4.Mechanical (HVAC) $ List: 5.Mechanical (Fire $ Suppression) Total All Fee Che No. � eck Amount: �Cash Amount: 6.Total Project Cost: $ 50,795 ®'Paid in Full 0 Outstanding Balance Due: SECTION 5: CONSTRUCTION SERVICES 5.1 Construction Supervisor License(CSL) CS-109847 12/04/2019 Scott Fournier License Number Expiration Date Name of CSL Holder List CSL Type(see below) U 67 Pearl Street No.and Street Type Description South Hadley, MA 01075 U I!nrestricted(Buildings up to 35,000 cu.ft.) R Restricted 1&2 Family Dwelling City/Town,State,ZIP M Masonry RC Roofing Covering ---- WS Window and Siding SF Solid Fuel Burning Appliances (413) 461-7076 scoff.fournier@allenergysolar.com I Insulation Telephone Email address D Demolition 5.2 Registered Home Improvement Contractor(HIC) 175144 04/24/2021 All Energy Solar _ HIC Registration Number Expiration Date HIC Company Name or HIC Registrant Name 159 Front Street isaac.lindstrom@allenergysolar.com No.and Street Email address Chicopee, MA 01013 (651) 842-9404 Ci /Town,State,ZIP Telephone SECTION 6:WORKERS'COMPENSATION INSURANCE AFFIDAVIT(M.G.L.c.152.§ 25C(6)) Workers Compensation Insurance affidavit must be completed and submitted with this application. Failure to provide this affidavit will result in the denial of the Issuance of the building permit. Signed Affidavit Attached? Yes ..........0 No...........❑ SECTION 7a:OWNER AUTHORIZATION TO BE COMPLETED WHEN OWNER'S AGENT OR CONTRACTOR APPLIES FOR BUILDING PERMIT 1,as Owner of the subject property,hereby authorize All Energy Solar to act on my behalf,in all matters relative to work authorized by this building permit application. See Permit Authorization Form 8/28/2019 Print Owner's Name(Electronic Signature) Date SECTION 7b:OWNER'OR AUTHORIZED AGENT DECLARATION By entering my name below,I hereby attest under the pains and penalties of perjury that all of the information contained in this application is true and accurate to the best of my knowledge and understanding. 8/28/19 Print Owner's or Authorized Agent's Name(Electronic Signature) Date NOTES: 1. An Owner who obtains a building permit to do his/her own work,or an owner who hires an unregistered contractor (not registered in the Home Improvement Contractor(HIC)Program),will not have access to the arbitration program or guaranty fund under M.G.L.c. 142A.Other important information on the HIC Program can be found at www.mass.gov/oca Information on the Construction Supervisor License can be found at www.mass.goy/dps 2. When substantial work is planned,provide the information below: Total floor area(sq.ft.) (including garage,finished basement/attics,decks or porch) Gross living area(sq.ft.) Habitable room count Number of fireplaces Number of bedrooms Number of bathrooms Number of half/baths Type of heating system Number of decks/porches Type of cooling system Enclosed Open 3. "Total Project Square Footage"maybe substituted for"Total Project Cost" ALL ENERGY 159 Front St Chicopee MA 01013 www.allenergys olar.com Property Owner ' Authc►rized AgentForm I hereby authorize All Energy Solar to act as my authorized agent in dealing with to obtain any and all required permits for the installation of a solar Photovoltaic system on my property located at �Jr OjAY�k(/ C� J Property Owner Date Printed Name .,''` �ac,�^art'' S�►� �r ,E tl The Commonwealth of Massachusetts T Department of Industrial Accidents I Congress Street,Suite 100 Boston, MA 02114-2017 ii,wi:mass.govIdia Wcst kers' Compensation Insurance Affidavit:Builders/Contractors/Electricians/Plumbers. TO BE FILED WITH THE PERMITTING AUTHORITY. Analicant Information Please Print Leoibl Name (Business/Organization/Individual):All Energy Solar Address: 159 Front Street City/State/Zip: Chicopee, MA 01013 Phone #:413-461-7621 Are von an emplotier?Check the Appropriate box: Type of project(required): LQ I am a employer with 98 employees(fill and/or pan-tine)." 7. 0 New construction 2.[]l am a sole proprietor or partnership and have no employees worl:iva for me in $. []Remodeling any capacity.[No workers'comp.insurance required.] 9. ❑Demolition 3.[:]l atm a homeowner doing all work myself.[No workers'comp.insurance required.]t 4.❑I am a homeowner acid will be hiring contractors to conduct iY PPent•t all work on n property. I will 10 Building addition ensure that all contractors either have workers'compensation insurance or are sole 11.[:]Electrical repairs or additions proprietors with no employees. 12.❑Plumbing repairs or additions 5.❑I am a general contractor and I have hired the subcontractors listed on the attached sheet. 13.❑Roof repairs These sub-contractors have employees and have workers'comp.insurance. 14.QOtlier solar 6.0 We are a corporation and its officers have exercised thein right of exemption per MGL c. 152.§1(4).and we have no employees.[No workers'comp.insurance required.] *Any applicant that checks box#1 must also fill out the section below shorting their workers'compensation policy information. t Homeowners who submit this affidavit indicating they are doing all work and then hire outside contractors must submit a new affidavit indicating such. tContractors that check this box must attached an additional sheet showing the name of the sib-contractors and state whether or not those entities have employees. If the sub-contractors have employees.they must provide their workers'comp.policy number. I atm an employer that is providing workers'contpensation insurance for tit•einplopees. Below is the policy and job site information. Insurance Company Name:Ace American Insurance Company Policy#or Self-ins.Li,. #: C65756377 Expiration Date: 10/1/2019 .lob site Address: 85 Winterberry Lane City/State/Zip: Northampton, MA 01062 Attach a copy of the workers'compensation policy declaration page(showing the policy number and expiration date). Failure to secure coverage as required under MGL c. 152,§25A is a criminal violation punishable by a fine up to$1,500.00 and/or one-year imprisonment,as well as civil penalties in the form of a STOP WORK ORDER and a fine of up to$250.00 a day against the violator.A copy of this statement may be forwarded to the Office of Investigations of the DIA for insurance coverage verification. 1 do hereby certify under lite pains mrd penalties of perjury that the information provided above is true and correct. Signature: Date: 8/28/19 Phone#:413-461-7621 Official use only. Do not it-rite in this area,to be completed bI cin or tor+-rt official. Cite or Town: Permit/License# Issuing Authority(circle one): 1.Board of Health 2.Building Department 3.City/Town Clerk 4.Electrical Inspector S.Plumbing Inspector 6.Other Contact Person: Phone#: ARC DESIGN 409 N. MAIN STREET E LMER, NJ 08318 (856) 712-2166 ]FAX: (856) 358-1511 Construction Code Office Date: August 5,2019 Re: Roof Certification Letter Subj: Smith Residence 85 Winterberry Lane Northampton,MA 01062 We have provided a review of the roof constructions of the above named property in regards to verifying the capacity of the existing roof for installation of a new Solar Panel Array. We have found the structure to be of wood frame construction. The roof is of 2x8 Ceiling Joist @ 16" with a 2x knee and a single layer of shingles system. The wood framed roof structure bears directly upon the framed exterior wall system. The existing members as installed will meet the required IRC-2015 design span ratings with sufficient capacity to cant'the 4#/sf additional load imposed by the proposed solar array per the details below. Installation of solar rack systems shall be as follows: Each panel row shall be supported upon 2 mounting rails. Rails shall be anchored directly to the metal roofing panel with a mating roof clip(S-5, UniRac, or equal). Rail attachment points to roof shall be 48-60"o.c. along rail length. Solar panel mounting systems installed parallel to the plane of a roof shall be no more than 12" above the roof when measured perpendicular to the roof surface. When installed per the above specifications the system shall meet the required 124 MPH wind load and 40 PSF ground snow load requirements. Should you have any further question or comment please feel free to contact our office. Respectfully, o J SA. G� CY -4 James A. Clancy 5 Cn Professional Engineer MA License#46775 James A. Clancy, PE a5 601 Asbury Avenue �S National Park, NJ 08063 Massachusetts PE Lic#46775 A B C D E F G H GENERALNOTES 1. FIELD VERIFY ALL MEASUREMENTS A ALL - - 2. ITEMS BELOW MAY NOT BE ON THIS PAGE ENERGY - - 3. NO SPECIAL ACCESS INSTRUCTIONS - 4. THERE ARE NO CLEARANCE ISSUES DUE I - - TO OVERHEADPOWERLINES 5. UTILITY ACDISCONNECT AND PV PRODUCTION METER ARE LOCATED TOGETHER IN A READILY ACCESSIBLE CONTRACTOR LOCATION WITHIN 10'OF THE MAIN SERVICE METER 2 6. 2417 UNESCORTED KEYLESS ACCESS ALL ENERGY SOLAR SHALL BE PROVIDED FOR THE UTILITY METERS AND AC DISCONNECT PHONE: 1642 620-3370 CARROL 1711-4" 1 DIBTANCES ADDRESS:1642 CARROLL AVE PV SOLAR PANELS-OFTYAZERS:S MAX ST PAUL,MN 55104 OPTIMIZERS-INVERTER 59 MAX UC.NO.: / INVERTER-PV PRODUCTIONAL METER 7 HIC.NO.: PI PRODUCTIONAL METER-UTILITY FUSED AC DISCONNECT:7 ELE.NO.: UTILITY FUSED AC DISCONNECT-MAIN ELECTRIGL PANEL AWN ELECTRICAL PAFEL-B14ARECTOR METER:5 UNAUTHDRIZED USE OF THIS DRAWING SET WITHOUT WRITTEN PERMISSION FROM CONTRACTOR IS IN VIOLATION OF US COPYRIGHT LAWS AND WILL BE SUBJECT TO CIVIL 3 ARRAY 2 1 DAMAGES AND PROSECUTIONS SOUR MODULES -PROPERTYUNE NEW PV SYSTEM:15.360 kVp � ----'--- 1001-3" (E) EXISTING ZACHARY SMITH AREA OF WORK I (N) NEW I - 27624 ARRAYI SOLAR MODULES 1 85 WINTERBERRYLN ° NORTHAMPTON,MA 01062 APN:NHAMM:0036B:0222L:0001 o .� ENGINEER OF RECORD D ENTRANCE O 1081-0" 1401-101 INTERIOR PV EQUIPMENT y E)(1)MAIN SERVICE PANEL / ACCOUNT&26524-36025 METER N:59180720 OID N:- 5 EXTERIOR PV EQUIPMENT (E)(1)BI-DIRECTIONAL METER <T0101 PAPERSIZE.n-xrr IANSIBI (N)(1)UTILITY FUSED AC DISCONNECT - (N)(1)PVPRODUCTIONAL METER / SITE PLAN _ (N)(1)INVERTER / DATE: 08.15.2019 - _ - DESIGN BY:I.S. CHECKED BY: M.M. SITE PLAN N REVISIONS 1132' W E 1/32'=1'-0' 0 76'1' 32'2' ® B A-101.00 A B C D E F G H ISHEET 3I A B C D E F G H GENERAL NOTES 1 1. FIELD VERIFY ALL MEASUREMENTS _��-/ALL 2. ITEMS BELOW MAY NOT BE ON THIS PAGE ENERGY 3. NO SPECIAL ACCESS INSTRUCTIONS snl.ae ROOF RAFERS ROOF MATERIAL IS 1 LAYER ASPHALT SHINGLE ROOF ATT.TYP.@ 48"MAX. 77(8"KNEE WALL&COLLAR CONTRACTOR TIE@24"0 C. 2 504" ALL ENERGY SOLAR 348" PHONE: (800)6203370 I. ADDRESS:1642 CARROLL AVE I i I I ST PAUL,MN 55104 4 ' 4_— I_4 SOLAR(PV)MODULE LIC.NO.: I I I I IT7 7 ARRAY I I I I I I I I I I I I I I I I I I I I I AY 2 HIC.NO.: ElI I I I I I i I I I I I I ---_.._ RAILS ELE.NO.: V I I I I I I I I I I + 1 DRAWN3SIET USE ofWRI I I I I I I I I I I I I I I I I I I I I I DRAVANc SET vnTHour WRITTEN ❑ I I I I I I I I I 1 I I I 1 I 1 I I 1 I PERMISSION FROM CONTRACTOR IS IN �.._____�-r. ,�, -� _' ATTACHMENTS VIOLATION OF U.COPYRIGHT LAWS AND WILL BE SUB.ECT TO CIVIL 3 Fl ❑ DAMAGESANDPROSECVTIONS. I I I I I I I I I I I 1 1 1 1 1 1 0 NEW PV SYSTEM:15.360 kWp I _I_ _._ ARRAY ZACH SMITH - - _- -3Z4 _ — --' FLUSH MOUNT SOLAR MODULES ATTACHED TO ROOF SURFACE(SEE 27624 SHEETS-501 FOR MOUNTING DETAILS) 348" 851MNTERBERRY LN NORTHAMPTON,MA 01062 4 NAME DESCRIPTION QTYJ APN:NHAMM:00366:02221-:0001 RACKING&MISC MATERIALS ENGINEER OF RECORD RAIL SPLICES 242-01214 ULTRA RAIL SPLICE 12 SNAP-N-RACK ATTACHMENTS KITS 242-92093 SNR ATTACHMENT KIT 48 FLASHINGS 232-01375 COMP FLASHING 96 L-FEET 242-01220 ULTRA RAIL UMBRELLA L FOOT 96 LAG BOLTS 242-92266 UMBRELLA LAG,TYPE 3,41N,SS 96 RAIL LENGTH 232-02451 UR-40 RAIL,1681N 24 GROUND LUG 242-02101 GROUND LUG ASSEMBLY,6-12 AWGI 6 MID CLAMP 242-02054 BONDING MID CLAMP 84 5 PAPERsze,UNIVERSAL END CLAMP 242-02215 UNIVERSAL END CLAMP 24 .I;LANs el SOLAR ATTACHMENT PLAN 40" DATE: 08.15.2019 DESIGN BY:I.S. MODULE: CHECKED BY: M.M. 6 SOLAR ATTACHMENT PLAN " 66.3811 LG ELECTRONICS REVISIONS 01 LG320N1 K-A5 0 54' 10'-8' s F azo WATTS A-103.00 A B C D E F G H 15HEe`' A B C D E F G H GENERALNOTES 1 1. FIELD VERIFY ALL MEASUREMENTS �L/ALL ARRAY 1 2. ITEMS BELOW MAY NOT BEONTHIS PAGE ENERGY 3. NO SPECIAL ACCESS INSTRUCTIONS SOLAR 4. THERE ARE NO CLEARANCE ISSUES DUE TO OVERHEAD POWERLINES 5. UTILITY AC DISCONNECT AND PV FR PRODUCTION METER ARE LOCATED CONTRACTOR TOGETHER IN A READILY ACCESSIBLE LOCATION WITHIN 10'OF THE MAIN SERVICE METER ALL ENERGY SOLAR 2 6. 2411 UNESCORTED KEYLESS ACCESS TO)ARRAYSHALL BE FRONDED FOR THE UTILITY 384° 396° PHONE: (600)620-3370 ADDRESS:1642 CARROLL AVE 300" 312" ST PAUL,MN 55104 LIC,NO.: HIC.NO.: HillO ELE.NO.: UNAUTHORIZED USE OF TMS (] m DRAWNG SET WTHOUT MITTEN PERMISSION FROM CONTRACTOR IS IN VIOLATION OF U S.COPYRIGHT LAWS AND MALL BE SUBJECT TO CIVIL 3pAMAGES MD PROSECUTIONS. TO(E)UTILITY TO(E)BI-DIRECTIONAL METER (N)(1)INVERTER NEW PV SYSTEM:15.360 kWp TO(E)MSP BUILDING ELEVATION (SE SIDE OF HOUSE) (N)(1)UTILITY FUSED AC DISCONNECT 01 NorroscALE ZACH SMITH ' (N)(1)PRODUCTION METER 27624 ARRAY 2 85 WINTERBERRY LN NORTHAMPTON,MA 01062 4 APN:NHAMM:0036B:0222L:0001 ENGINEER OF RECORD HE FE] 288" 276" 5 216" 204" ® F" PAPERSIZE.fl'v tr lAN$I BI M] H u IH ELEVATION PLAN 0 Lul Fl DATE: 06.15.2019 DESIGN BY:I.S. CHECKED BY: M.M. 6 02 BUILDING ELEVATION (NW SIDE OF HOUSE) REVISIONS UL NOT TO SCALE A-104.00 A B C D E f G H ISHEETsI A B C D E F G H O GENERAL NOTES \t/ALL II 27 - 1. FIELD VERIFY ALL MEASUREMENTS ' ENERGY 4 5 8 SOLAR 3 I , 11 13 14 15 18 22 12 CONTRACTOR 23 24 25 2 ALL ENERGY SOLAR RACKING DETAIL (LONGITUDINAL) O SHEET KEYNOTES PHONE: (800)6203370 NOT TO SCALE ADDRESS:1642 CARROLL AVE 1. ROOF MATERIAL.ASPHALT SHINGLE ST PAUL,MN 55104 2. ROOF STRUCTURE.KNEE WALL d COLLAR TIE 3. ATTACHMENT TYPE:SNAP-N-RACK ULTRA RAIL COMP KIT LIG NO.: VA 4. MODULE MANUFACTURER:LG ELECTRONICS HIC.NO.: RACKING DETAIL TRANSVERSE 5. MODULEMODELL66.38 K-AS ELE.UT1O0RTHS D 1 6 MODULE WIDTH 66.38' ORADTNGR1E WTH O ARI 7. MODULE WIDTH'.40' oRAw�NC SEi vAT1K)Ui KRITTEN NOT TO SCALE 8. MODULE WEIGHT.39.68 LBS. PERMIT FROM CONTRACTOR ISIN 9. EE SHEET M103 FOR DIMENSION(S)SANo WILLSESDBJECTTOCIVIL 3 10. MIN.FIRE OFFSET NO FIRE CODE ENFORCED DAMAGESAND PROSECLMONs. O O 11. TRUSS SP ACING:241N.O.C. 12. TRUSS SIZE:26 NOMINAL NEW PV SYSTEM:15.360 kWp 13. LAG BOLT DIAMETER:51161N. 14. LAG BOLT EMBEDMENT:2.51N, 0 � 15. TOTAL AREA 88507 SO.TS FT. 6. ZACH SMITH - 10 1 6. TOTAL AREA.885.07 S0.FT. 17. TOTAL WEIGHT:2120.64 LBS, 18. WEIGHT PER ATTACHMENT:22.09 LBS, 4 19. DISTRIBUTED LOAD:2.4 PSF L f276262 20. MAX.HORIZONTAL STANDOFF:481N, 21. MAX.VERTICAL STANDOFF: 0 t1 LANDSCAPE:25 IN.,PORTRAIT:331N. 85 WINTERBERRY LN 22. STANDOFF STAGGERING:YES 23. RAIL MANUFACTURER(OR EQUIV.):SNAP N RACK NORTHAMPTON,MA 01062 4 24, RAIL MODEL(OR EQUIVALENT):UR-40 RAIL 25, RAIL WEIGHT:0.42PLF. APN:NHAMM:0036B:0222L:0001 26. MAX.RAFTER SPAN:B' ENGINEER OF RECORD 27. MODULE CLEARANCE:31N.MIN.,6IN.MAX. O RACKING DETAIL (TOP) U NOT TOSCALE 5 p PAPER SEE.11"e 17(ANSI B) ASSEMBLY DETAILS DATE: 08.152019 DESIGN BY:I.S. CHECKED BY: M.M. 6 � DETAIL (TRANSVERSE) D5 DETAIL (LONGITUDINAL) REVISIONS u� WTO SCALE V NOT TO SCALE S-501.00 A R C D E F G H (Seat 11) A B C D E F G H 1 I:/ALL _ ENERGY DESCRPTION: DRAWN BY: DESCRIPTION: -_- DRAWN BY r SNAPNRACK,UR-40 RAIL mwatklns =i,1� SNAPNRACK,ULTRA RAIL COMP KIT mwatklns 5miciL�� U ac —— Solar Mounting Solutions Solar Mounting Solutions REVISION: _ ..._..._ REVISION: � .. ........_ ....—.__ PART NUMBER(S): PART NUMBER(S)'. w �•�-�m_Gw� CONTRACTOR ..oewaeo®.wl�e 232-02449,232-02450,232-02451 SEE BELOW 2 ... ALL ENERGY SOLAR UR-40 RAIL \ \ i PHONE: (800)620J370 PROPERTIES -- � f ��.; - I ADDRESS:1642 CARROLL AVE SKU FINISH ST PAUL,MN 55104 232-02449 MILLv 232-02450 CLEAR/ LIGNO.: 232-02451 BLACK / �/� , .� ELE NO.: UNAUTHORIZED USE OF THIS ( / 1 DRAW NG 5E FROM TRAT EN PERMISSION FROM CO NACT OR IN` IUS COPYRRIGHL T LAWS S AN KILL LLBE SUBJECT TO CIVIL / DANAGESANDPROSECU ONS ' NEW PV SYSTEM:15.360 kWp ®- ZACH SMITH - m 31 27624 1111III 85 WINTERBERRYLN A31 I 0 NORTHAMPTON,MA 01062 4 I APN:NHAMM:0036B:0222L:0001 I ENGINEER OF RECORD EQUIVALENT PROPERTIES 1.624 A 0.3571n' I �... .. Ixz 0.125 ins \1'l] CENTROID IYY 0.132 i 0 Sx(TOP) _ 0.150 ina 792 Sz(BOT) 0.158 ina )� Sy(LEFT) 0.175 ina ....._-- PARTS LIST - - Sy(RIGHT) 0.175 ina - ITEM QT'Y 'PART NUMBER DESCRIPTION -- 1___-...I_f= 1 1 242-92266 SNAPNRACK,UMBRELLA LAG,TYPE 3,41N,SS 2 1 242-01219,242-01220 SNAPNRACK,ULTRA FOOT FOR U FLASHING,SILVER/BLACK — 5 ALL DIMENSIONS IN INCHES - - - -- PAPER SIZE n"ar�ANslsi 3 1 232-01375,232-01376 SNAPNRACK,COMP FLASHING,9IN X 121N,SILVER/BLACK ALUM MATERIALS: 6000 SERIES ALUMINUM OPTIONS: MATERIALS: 6000 SERIES ALUMINUM,STAINLESS STEEL,RUBBER - -- - RESOURCE DOCUMENT ........... .__—_ _.._.. DESIGN LOAD(LBS): N/A CLEAR/BLACK ANODIZED �DESIGN LOAD(LBS): 405 UP,788 DOWN,236 SIDE ULTIMATE LOAD(LBS): _.N/A MILL FINISH IMATE LOAD(LBS): 2006 UP,4000 DOWN,1070 SIDE DATE: 08.152019 TORQUE SPECIFICATION: N/A LB-FT ,BUNDLES OF 144 QUE SPECIFICATION: 12 LB-FT DESIGN BY:IS. CERTIFICATION: LL 2703,FILE E359313 BOXES OF 6 "CERTIFICATION:-- UL 2703,FILE E359313;WIND-DRIVEN RAIN TEST FROM UL SUBIECi 2582 WEIGHT(LBS): 5.85 WEIGHT(LBS); .0.80 CHECKED BY: M.M. 6 REVISIONS R-004.00 A B C D E F G H IB BET 1S) A B C D E F G H I DESCRIPTION _.... _._ _ _-_.. DRANM BY: DESCRIPTION: _ DRAWN BY: rr _\1 /ALL ENERGY SNAPNRACK,ULTRA RAIL COMP KIT mwagdns Qv. SNAPNRACK,ULTRA RAIL COMP KIT mwatlons Solar Mounting Solutions REVISION: Solar Mounting Solutions _._... REVISION: .. _.._.... _ ___.. PART NUMBER(S), PART NUMBER(S): SEE BELOW SEE BELOW ---- -----�r CONTRACTOR —` UMBRELLA L FOOT PROPERTIES 2 /// \ SKU DESCRIPTION ALL ENERGY SOLAR 242-01219 ULTRA RAIL UMBRELLA L FOOT,SILVER F: 242-01220 ULTRA RAIL UMBRELLA L FOOT,BLACK PHONE: (600)620-3370 1.37 01.00- ADDRESS:1642 CARROLL AVE .38 M 30 ST PAUL,MN 55104 ................. SLOT LIC.NO 1 1 1.SD I\ F UNAUTNDRIZED ll SE OF THIS 3.25. 1 �' �......t DRAWING SET WITHOUT WRITTEN 2.76 —. 1 PERMISSION FROM CONTRACTOR IS IN 1.62.-+ ANDWLVIOLONE UB EOPv JECT IGWCIVIL s TO 3 I,Z _ �.1 I. I WM4GES AND PROSECUTIONS. 1.80 - 1 1.50 ..^' NEW PV SYSTEM:15.360 kWp - -11 2 COMP FLASHING PROPERTIES L7 SKU DESCRIPTION ZACH SMITH I � 3 232-01375 COMP FLASHING,9-X 12',BLACK ALUM _ 232-01376.COMP FLASHING,9"X 12",SILVER ALUM 27624 85 WINTERBERRY LN 4 C NORTHAMPTON,MA 01062 o r- ����� 30 ^ '- 01 °0 APN:NHAMM:00366:0222L:0001 0,75 N. w ENGINEER OF RECORD �-- 11.75 PARTS LIST 1 4.20 ITEM QTY PART NUMBER DESCRIPTION 1050 .. NAP IN_..RACK,UMBREL _. .. i-— 2 1 242 01219 242-01220 SNAPNRACK ULTRA FOOT FOR U FLASHING,SILVER/BLACK � l _ 3 1 232-013759232601376 SNAPNRACK COMP FLASHING, IN X LA LAG,TYPE 3,121N,S SILVER/BLACK ALUM'. rA o 5 - -'x•35PAPER SIIE 11'.IP IANSI BI [MATEPSALS 6000 SERIES ALUMINUM,STAINLESS STEEL,RUBBER '. 3.25 /1'I _ DESIGN LOAD(LBS): 405 UP,788 DOWN,236 SIDE RESOURCE DOCUMENT ULTIMATE LOAD(LBS) -;.2006 UP,4000 DOWN,1070 SIDE _ _�— TORQUE SPECIFICATION: 12 LB-FT - H 45 w DATE: 06.15.2019 CERTIFICATION: UL 2703,FILE E359313;WIND-DRIVEN RAIN TEST FROM UL SUB3ECT 2582 .. WEIGHT(LBS): 0.80 ALL DIMENSIONS IN INCHES DESIGN BY:I.S. CHECKED BY: MM. REVISIONS 6 R-005.00 A B C D E F G --- A 8 C D E F G H I./ALL LIGN . ENERGY s0un LG NeON'2 Black ®usa= �. LG320N1K-V5 LG320N1K-V5 GeoealDatar, e ,z_ CONTRACTOR ---- _-- — Mena xcvoN,x.v6 c"663"- `" ""iin1bi`R"'J 330 ALL ENERGY SOLAR 2 333 320W -- CA Ca 4^oon (ba°) 1/PMYPtt�tiL [el Nu,araB.bet lF} MWor.n Uvd ,tAl 9b3 -ear o--wn(Law.M ,6ebmm.,At6me.Aomm OP�[6eJrwM"NA35pI IVl A°.B 1°.,9 --- - ----The LG LG NeONo 2 is LG's bei selling Solar module,and is one of the most 6untMnexa7 _... -w�2a,,uu m,�nR c:.,,�t Mo0YE11kYiay T%1 ,e] PHONE: (800)620-3310 Dowerful and vefsatile modules on the market today-Featuring LG's Cello °-3 --__ ---- ADDRESS:1642 CARROLL AVE Nev,Technology,the LG NeONAr 2 increases power output. updates include F—iA.xamer�irrm�ao�oea". : ^�^� .�+.cwd� ,x: , ST PAUL,MN 55104 an extended performance warranty from 86%to 896%to give customers r,,r.twynr ,.Mir-.]en Op"Cardioms LIC.NO.: higher performance and reliabil c�.r nwe3M.i.a uciur aww6yao.�.. _. t<l- ,ntxA,z,u3,o-f; 9 Pe Iry. ____... - ____.. M...-sxrAweT _ D7__ .0 9c HIC.NO.: — C E o ENE.NO.: Certifications ar,O Warranty 1Ytlr lol6t W(Fwa) _,- LA pa) 5}o0 r,t3 UNAUT"iZEDUSEOF'THS RI ORAWNGSETWITHOUT RACTEN ,wa-°esy�buxsn.y'nan 6] PERMISSION FROM LONiRPLTOR IS IN „ "� Com"'f1p1y itp 9rv;�.w is"ta,�RO SMH�, MOLATION OF U.S.COPYRIGHT LAWS Pare Configuration AND HALL BE SUBJECT TO CIVIL 3A4— °N�s wC,C,f n.e.araurwvrr_ lW_, 35 DAMAGES AND PROSECUTIONS SW w,Cw.or-ren 3se.,,ms Nwral Mehr w—mosriiii ul bso USAr_t_ A—Crr-�, b 3°3 ..a�..a_...a`..m Ix-)- so"'•'3°"": NEW PV SYSTEM:15.360 kWp n.-w.rArna� rAmae r..Pram. m t ,. nasWrrrsw/e - lh1 eve r,e R.aq .ctu_]9o,ucuuRoc,mm tM� sax MmrR-6xt w..>,ry __. 35 rvav �- Imm/inch) ZACH SMITH - - 27624 PAa IrV'cl 936. '--- I -1 85 WINTERBERRY LN NORTHAMPTON,MA 01062 ° Ercmio+apaw6fNMOT) APN:NHAMM:003613:02221-:0001 G1m'" ENGINEER OF RECORD In ANPCum l eoH ;(Al� ]s] � Features prix,r3mYt WrerervAtt!In 3G3 4,stCwtcumr(ts) tA1 Enhanced Performance Warranty Enhanced Product Warranty -V C— LIS I f LG NeONir 2 has an enhanced perfomame LG has extended the warranty of the NeONO 2 •x warranty.After 25 years,LG NeONO 2,s guar- to 25 years,which is among the top of industry .need to perform at minimum 89.6%of-tial standards. performance. _ 5 � PAPER SIZE n"a 1T'(ANSI BI Better Performance on a Sunny Day Roof Aesthetics ,c a RESOURCE DOCUMENT LG NeONO 2 now performs better on sunny LG Ne0!Vo 2 has been designed arch aesthetics m days,thanks to its Improved temperature mind using thinner wires that appear all black at a Coefficient distarce.The LG NeONo 2 can increase the aesthetic DATE: 08.15.2019 Value of your home with a.more modern design. '3"irl DESIGN BY;I.S. About LG Electronics BY: M.M. Lcs .....__ s � G tMl �. � �...w�n�- ,�,� olio .. Y� Rn✓' N r-a err mepa ryuma].errvn ,nWN •elism � W3](M,x YS.,,K.Vero, REVISIONS LG W 6n69 R-001.00 A B C 0 ME F G H (SHEEr 12) L Office of Consumer Affairs and Business Regulation 1000 Washington Street - Suite 710 Boston, Massachusetts 02118 Home Improvement Contractor Registration Type: Corporation -_ Registration: 175144 ALL ENERGY SOLAR INC =- " —� Expiration: 04/24/2021 159 FRONT ST CHICOPEE,MA 01013 Update Address and Raturn Card. -SCA-1 0-26I-M7 Office of Consumer Affairs&Business Regulation HOME IMPROVEMENT CONTRACTOR Registration valid for Individual use only TYPE:Comoration before the expiration date. If found return to: Reoistrid! ExpiraIIQ Office of Consumer Affairs and Business Regulation 175144 04124!2021 1000 Washington Street -Sulte 710 ALL ENERGY SOLAR INC Boston,MA 02118 MICHAEL ALLEN �~ 159 FRONT ST CHICOPEE,MA 01013 Not valid without signature Undersecretary Massachusetts Departmaint of Public SaWy f Board of Building Regulations and Standards L tc!ense: GS•1©9847 SCOTT FOURNIER 67 PEARL STREET SOUTH HADLEY MA 01076 nmissi+o ner 12/04t2019 ALLENER-02 SANDERSON ACORO CERTIFICATE OF LIABILITY INSURANCE DATE(MMIDDnrrv)7/15/2019 THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER.THIS CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S),AUTHORIZED REPRESENTATIVE OR PRODUCER,AND THE CERTIFICATE HOLDER. IMPORTANT: If the certificate holder is an ADDITIONAL INSURED,the policy(les)must have ADDITIONAL INSURED provisions or be endorsed. If SUBROGATION IS WAIVED, subject to the terms and conditions of the policy,certain policies may require an endorsement. A statement on this certificate does not confer rights to the certificate holder in lieu of such endorsement(s). PRODUCER CONTACT NAME: SF Insurance Group LLC PHONE FAX 744 Ryan Dr Ste 101 (A/C,No,Ext): 715)294-5946 AIC,No):(715)755-3228 Hudson,WI 54016 Ey4wp .sandemon sfinsurancegroup.com INSURERS AFFORDING COVERAGE NAIC A INSURER A:PrOSI Flt INSURED INSURER B: All Energy Solar Inc _INSURER C: 1264 Energy Lane INSURER D: Saint Paul,MN 55108 INSURER E INSURER F COVERAGES CERTIFICATE NUMBER: REVISION NUMBER: THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED. NOTWITHSTANDING ANY REQUIREMENT, TERM OR CONDITION OF ANY CONTRACTOR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN, THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CONDITIONS OF SUCH POLICIES.LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS. INSR TYPE OF INSURANCE ADDL SUBR POLICY NUMBER POLICY EFF POLICY EXPLTR LIMITS A X COMMERCIAL GENERAL LUUIILITY EACH OCCURRENCE 1,000,000 CLAIMS-MADE ]X OCCURPK201900016768 3/26/2019 31262020 DAMAGE TO Roccurrence) 111 ENTED 100,000 MED EXP(Any oneperson) 5,000 PERSONAL 3 ADV INJURY 1,000,000 GEN'L AGGREGATE LIMIT APPLIES PER: GENERAL AGGREGATE 2,000,000 POLICY F�wpT F-]LOC PRODUCTS-COMP/OP AGO 2,000,000 OTHER CAPPED DESIGNAT 5,000,000 COMBINED SINGLE LIMIT 1,000,000 A AUTOMOBILE LIABILITY E accident) _ ANY AUTO AU201900016763 3/26/2019 3/26/2020 BODILY INJURY(Per arson _ OWNED SCHEDULED AUTOS ONLY X AUTOS BODILY INJURY Per accident X AUTOS ONLY X AUTO ONEDY PROs rd AMAGE A X UMBRELLA LIAB X OCCUR PPFAeeCH OCCURRENCE 5'000'000 EXCESS LIAR CLAIMS-MADE UM201900007951 3126/2019 3/2612020 AGGREGATE 5,000,000 DED I X I RETENTIONS 10,000 WORKERS COMPENSATION AND EMPLOYERS'LUIBILITY YIN IMUTE i I R ANY PROPRIETOR/PARTNER/EXECUTIVE ❑ E.L.EACH ACCIDENT OFFICER/MEMBEF.t EXCLUDED? N/A (Mandatory in NH) E.L.DISEASE-EA EMPLOYE If yes,describe under DESCRIPTION OF OPERATIONS below E.L.DISEASE-POLICY LIMIT III DESCRIPTION OF OPERATIONS/LOCATIONS I VEHICLES (ACORD 101,Additional Remarks Schedule,may be attached if more space Is required) CERTIFICATE HOLDER CANCELLATION SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE Ci of Northampton THE EXPIRATION DATE THEREOF, NOTICE WILL BE DELIVERED IN City P ACCORDANCE WITH THE POLICY PROVISIONS. Building Commissioner's Office 212 Main St. Northampton,MA 01060 AUTHORIZED REPRESENTATIVE :ltilEG/��7'LIJ�"Gf//���r✓Eµli i�� ACORD 25(2016/03) ©1988-2015 ACORD CORPORATION. All rights reserved. The ACORD name and logo are registered marks of ACORD