24D-288 168 CRESCENT ST BP-2020-0128 GIs#: COMMONWEALTH OF MASSACHUSETTS Map:Block:24D-288 CITY OF NORTHAMPTON Lot:-001 PERSONS CONTRACTING WITH UNREGISTERED CONTRACTORS Permit: Building DO NOT HAVE ACCESS TO THE GUARANTY FUND (MGL c.142A) Category: SOLAR ELECTRIC SYSTEM BUILDING PERMIT Permit# BP-2020-0128 Proiect# JS-2020-000206 Est.Cost: $16829.00 Fee: $75.00 PERMISSION IS HEREBY GRANTED TO: Const.Class: Contractor., License: Use Group: DEVLIN CONTRACTING & MAINTENANCE 111884 Lot Size(sq.ft.): 4704.48 Owner: SHOTLAND JEFFREY Zoning: URB(100)/ Applicant. DEVLIN CONTRACTING & MAINTENANCE AT. 168 CRESCENT ST Applicant Address: Phone: Insurance: 86 FINNF,LL DRIVE SUITE 21 (781) 812-0420 Workers Compensation WEYMOUTHMA02188 ISSUED ON.8/1/2019 0:00:00 TO PERFORM THE FOLLOWING WORK:13 PANEL ROOF MOUNT SOLAR - 4.225 KW POST THIS CARD SO IT IS VISIBLE FROM THE STREET Inspector of Plumbing Inspector of Wiring D.P.W. Building Inspector Underground: Service: Meter: Footings: Rough: Rough: House# Foundation: Driveway Final: Final: Final: Rough Frame: Gas: Fire Department Fireplace/Chimney: Rough: Oil: Insulation: Final: Smoke: Final: THIS PERMIT MAY BE REVOKED BY THE CITY OF NORTHAMPTON UPON VIOLATION OF ANY OF ITS RULES AND REGULATIONS. Certificate of Occupancy Signature: FeeType: Date Paid: Amount: Building 8/1/2019 0:00:00 $75.00 212 Main Street,Phone(413)587-1240, Fax:(413)587-1.272 Louis Hasbrouck—Building Commissioner :z'- a Llq,. 090t0VY1'N01d1NVHta0 4 Department use only Io3dSN1 U ldlln9 d0 �--� City of No ha �us o Permit: -, .r Building D part ent C rb Cu Driveway Permit 212 Mal Stret slot �(�(' S wer/S ptic Availability Room 100 W 3terAA ell Availability Northampton MA 1060 Ly lo Sets of Structural Plans n = phone 413-587-1240 Fax 4t/Site Plans ecify APPLICATION TO CONSTRUCT,ALTER, REPAIR, RENOVATE OR DEMOLISH A ONE OR TWO FAMILY DWELLING SECTION 1 -SITE INFORMATION Q v - 20 —I Z2F 1.1 Property Address: This section to be completed by office Ibt� Cresccf-)T St- Map Lot Unit NCharm . mA 010c Zone Overlay District Elm St.District CB District SECTION 2-PROPERTY OWNERSHIP/AUTHORIZED AGENT 2.1 Owner of Record: ST. me(Print) Current Mallin Addr ss: l , �!%gi � I ll Telephone Sig a 2.2 Authorized A ent: i e(Print) urrent Mailing Address: Signatur Telephone SECTION 3 -ESTIMATED CONSTRUCTION COSTS Item Estimated Cost(Dollars)to be Official Use Only completed by permit applicant 1. Building 41 (a)Building Permit Fee 2. Electrical _ \ (b)Estimated Total Cost of �YJ Construction from 6 3. Plumbing Building Permit Fee �( 4. Mechanical(HVAC) `fT� 5. Fire Protection 6. Total=0 +2+ 3+4+5) , �� Check Number This Section For Official Use Only Building Permit Number: Date Issued: Signature: Z017 Building Commissioner/Inspector of Buildings Date EMAIL ADDRESS (REQUIRED; EITHER HOMEOWNER OR CONTRACTOR) Section 4. ZONING All Information Must Be Completed. Permit Can Be Denied Due To Incomplete Information Existing Proposed Required by Zoning This column to be filled in by Building Department Lot Size Frontage Setbacks Front Side L: R: L: R: Rear Building Height Bldg. Square Footage % Open Space Footage % (Lot arca minus bldg&paved parking) #of Parking Spaces Fill: volume&Location A. Has a Special Permit/Variance/Finding a er been issued for/on the site? NO O DON'T KNOW YES O IF YES, date issued: IF YES: Was the permit recorded at the Registry of Deeds? NO O DON'T KNOW © YES IF YES: enter Book Page and/or Document# B. Does the site contain a brook, body of water or wetlands? NO e DON'T KNOW O YES O IF YES, has a permit been or need to be obtained from the Conservation Commission? Needs to be obtained ® Obtained O Date Issued: C. Do any signs exist on the property? YES O NO IF YES, describe size, type and location: D. Are there any proposed changes to or additions of signs intended for the property? YES ® NO IF YES, describe size, type and location: E. Will the construction activity disturb(clearing,grading,excavation,or filling)over 1 acre or is it part of a common plan that will disturb over 1 acre? YES O NO O IF YES,then a Northampton Storm Water Management Permit from the DPW is required. SECTION 5-DESCRIPTION OF PROPOSED WORK(check all applicable) New House ❑ Addition ❑ Replacement Windows Alteration(s) ❑ Roofing ❑ Or Doors F-1 Accessory Bldg. ❑ Demolition ❑ New Signs [❑] Decks [E:] Siding ] Other IW Brief De cription of Proposed �'�'r-�`S L''�' Work: ' ( P4-CJSe, t11(ciz ,c Ifln tyrpoci s-Cfuict. stYucairw Lxq Alteration of existing bedroom Yes No Adding new bedroom Yes No jLC�.t Attached Narrative Renovating unfinished basement Yes No Plans Attached Roll -Sheet 6a. If New house and or addition to existing housing, complete the following: a. Use of building : One Family Two Family Other b. Number of rooms in each family unit: Number of Bathrooms c. Is there a garage attached? d. Proposed Square footage of new construction. Dimensions e. Number of stories? f. Method of heating? Fireplaces or Woodstoves Number of each g. Energy Conservation Compliance. Masscheck Energy Compliance form attached? h. Type of construction i. Is construction within 100 ft.of wetlands? Yes No. Is construction within 100 yr. floodplain Yes No j. Depth of basement or cellar floor below finished grade k. Will building conform to the Building and Zoning regulations? Yes No. I. Septic Tank City Sewer Private well City water Supply SECTION 7a-OWNER AUTHORIZATION -TO BE COMPLETED WHEN OWNERS AGENT OR CONTRACTOR APPLIES FOR BUILDING PERMIT I, dcpp � as Owner of the subject property ��l`` � o t h authorize b1n M �.�C �'1 ►U � 1 t act oh my behalf,77== z by this building permit application. —f, Signa ure of Owner Date I'* Ain Cinbachng fMQihrrmncf as Owner/Authorized Agent hereby declare that the statement a d information on the foregoing app ication are true and accurate,to the best of my knowledge and belief. Signed under the pains and penalties of perjury. O` Print Name r Sign ure of Owner/Agent Date SECTION 8-CONSTRUCTION SERVICES 8.1 Licensed Construction Su ervisor: Not Applicable ❑ Name of License Holder GS' I I I Ek-S9 License Number l`�-�{� Expiration Date �l Z. �L� i a ure Telephone 9.Registered Home Improvement Contractor: Not Applicable ❑ Company Name Registration Number roll �fi�. ZI ��rFl? ISG a , 3, 2-1 OZ!ZS16 Expiration Date Telephone . SECTION 10-WORKERS' COMPENSATION INSURANCE AFFIDAVIT(M.G.L.c. 152,§25C(6)) Workers Compensation Insurance affidavit must be completed and submitted with this application. Failure to provide this affidavit will result in the denial of the issuance of the building permit. Signed Affidavit Attached Yes....... ❑ No...... ❑ City of Northampton Massachusetts a��S,S scf`r DEPARTMENT OF BUILDING INSPECTIONS D 212 Main Street • Municipal Building Jti• �+� Northampton, MA 01060 Jg •• ,�0 AFFIDAVIT Home Improvement Contractor Law Supplement to Permit Application The Office of Consumer Affairs and Business Regulation("OCABR")regulates the registration of contractors and subcontractors performing improvements or renovations on detached one to four family homes.Prior to performing work on such homes,a contractor must be registered as a Home Improvement Contractor("HIC"). M.G.L.Chapter 142A requires that the"reconstruction, alteration,renovation,repair,modernization, conversion, improvement, removal, demolition,or construction of an addition to any pre-existing owner-occupied building containing at least one but not more than four dwelling units....or to structures which are adjacent to such residence or building"be done by registered contractors. Note:If the homeowner has contracted with a corporation or LLC,that entity must be registered Type of Work:LSdo l- spa) Est. Cost: 1(c), Address of Work:, Cmacnt & Kb4f lUj�ptw1._ 9 jq Date of Permit Application: la . 19 1 hereby certify that: Registration is not required for the following reason(s): _Work excluded by law(explain): _Job under$1,000.00 Owner obtaining own permit(explain): Building not owner-occupied Other(specify): OWNERS OBTAINING THEIR OWN PERMIT OR ENTERING INTO CONTRACTS WITH UNREGISTERED CONTRACTORS OR SUBCONTRACTORS FOR APPLICABLE HOME IMPROVEMENT WORK ARE NOT ELIGIBLE FOR AND DO NOT HAVE ACCESS TO THE ARBITRATION PROGRAM OR GUARANTY FUND UNDER M.G.L.Chapter 142A.SUCH OWNERS ALSO ASSUME THE RESPONSIBILITES FOR ALL WORK PERFORMED UNDER THE BUILDING PERMIT.SEE NEXT PAGE FOR MORE INFORMATION. Signed under the penalties of perjury: I hereby apply for a building permit as the agent of the owner: Date Contractor Name HIC Registration No. OR: Notwithstanding the above notice, I hereby apply for a building permit as the owner of the above property: Date Owner Name and Signature City of Northampton �5 . . s. Massachusetts (. DEPARTMENT OF BUILDING INSPECTIONS yv. . \ 212 Main Street *Municipal Building b.,. D Northampton, MA 01060 ssyjy ,^JP Debris Disposal Affidavit In accordance of the provisions of MGL c 40, S54, I acknowledge that as a condition of the building permit all debris resulting from the construction activity governed by this Building Permit shall be disposed of in a properly licensed solid waste disposal facility, as defined by MGL c 111, S 150A. The debris from construction work being performed at: II (=L V' --)C 11-. CfPSCPn-1- (Please print house number and street name) Is to be disposed of at: Z� OfflDst' Q- 4YdinCCnf0a0q (Please print name and location of facility) Or will be disposed of in a dumpster onsite rented or leased from: (Company Name and Address) Signat ermit Applicant or Owner Date If, for any reason, the debris will not be disposed of as indicated, the Applicant or Owner shall notify the Building Department as to the location where the debris will be disposed. Commonwealth of Massachusetts t� Division of Professional Licensure Board of Building Regulations and Standards ConstrylCtl6d%Upsrvisar CS-111884 fir, f Wires:08/2112021 J BENJAMIN T O'CONNELL 74 BAYVIEW AVE QUINCY MA 02160 Commissioner .�e �irrma��aca�/�o���a•J1a�i-Jct/J Office of Consumer Affairs&Business Regulation HOME IMPROVEMENT CONTRACTOR TYPE:Supplement Card Registration valid for individual use only Registration Expiration before the expiration date. If found return to: 182869 08/03/2021 Office of Consumer Affairs and Business Regulation DEVLIN CONTRACTING AND MAINTENANCE INC. 10 Park Plaza-Suite 6170 Boston,MA 02116 BENJAMIN OCONf}i LL ` � . 86 FINNELL DR tl21"` WEYMOUTH,MA 02188 Undersecretary Not vaii without signature t'b The Commonwealth of Massachusetts Department of Industrial Accidents Office of Investigations 600 Washington Street Boston, MA 02111 www.mass.gov/dia Workers' Compensation Insurance Affidavit: Builders/Contractors/Electricians/Plumbers Applicant Information Please Print Leeibly Name (Business/Organization/Individual): Devlin Contracting&Maintenance Address: 86 Finnell Dr.Ste.21 City/State/Zip: e mouth, Ma 02188 Phone 4: 781-812-0240 Are you an employer?Check the appropriate box: Type of project(required): 1. I am a employer with 15 4. [1I am a general contractor and 1 6. New construction employees(full and/or part-time).* have hired the sub-contractors 2. I am a sole proprietor or partner- listed on the attached sheet. + Remodeling ship and have no employees These sub-contractors have 8. 0 Demolition working for me in any capacity. workers' comp. insurance. 9. ® Building addition [No workers' comp.insurance 5. [3 We are a corporation and its 10 [0 Electrical repairs or additions required.] officers have exercised their 3.El I am a homeowner doing all work right of exemption per MGL I I .E3 Plumbing repairs or additions myself. [No workers' comp. c. 152, §1(4),and we have no 12.[0Roof repairs insurance required.] t employees. [No workers' 13.00ther Solar Install comp. insurance required.] *Any applicant that checks box#I must also fill out the section below showing their workers'compensation policy information. t Homeowners who submit this affidavit indicating they are doing all work and then hire outside contractors must submit a new affidavit indicating such. =Contractors that check this box must attached an additional sheet showing the name of the sub-contractors and their workers'comp.policy information. I am an employer that is providing workers'compensation insurance for my employees. Below is the policy and job site information. Insurance Company Name: Guard-Insurance Policy #or Self-ins. Lic.#: Expiration Date: 04/03/2020 168 Crescent St. Northampton, Ma 010E Job Site Address: City/State/Zip: Attach a copy of the workers' compensation policy declaration page(showing the policy number and expiration date). Failure to secure coverage as required under Section 25A of MGL c. 152 can lead to the imposition of criminal penalties of a fine up to$1,500.00 and/or one-year imprisonment,as well as civil penalties in the form of a STOP WORK ORDER and a fine of up to$250.00 a day against the violator. Be advised that a copy of this statement may be forwarded to the Office of Investigations of the DIA for insurce coverage verification. I do hereby certify and 'ns a penalties of perjury that the information provided above is true and correct. 07/30/2019 Si nature: Date: Phone#: 781-812-0240 Official use only. Do not write in this area,to be completed by city or town official. City or Town: Permit/License# Issuing Authority(circle one): 1. Board of Health 2. Building Department 3. City/Town Clerk 4. Electrical Inspector 5. Plumbing Inspector 6. Other Contact Person: Phone#: DEVLCON-01 MGOMEZ �4*� o CERTIFICATE OF LIABILITY INSURANCE DATE(MMI019 DDNYYY) THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER.THIS CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S),AUTHORIZED REPRESENTATIVE OR PRODUCER,AND THE CERTIFICATE HOLDER. IMPORTANT: If the certificate holder is an ADDITIONAL INSURED,the policy(ies)must have ADDITIONAL INSURED provisions or be endorsed. If SUBROGATION IS WAIVED, subject to the terms and conditions of the policy,certain policies may require an endorsement. A statement on this certificate does not confer rights to the certificate holder in lieu of such endorsement(s). PRODUCER C NTACT R.S.Gilmore Insurance �A/c°O,Nr o,EXt:(508)699-7511 W .Noy(608)695-3597 27 Elm St M North Attleboro,MA 02760 INSURERS AFFORDING COVERAGE NAIC# INSURER A:EMC Insurance Com anies 25186 INSURED INSURERB:AmGuard Ins Co Devlin Contracting&Maintenance,Inc. INSURER C: 86 Finnell Drive INSURER D: Weymouth,MA 02188 INSURER E INSURER F: COVERAGES CERTIFICATE NUMBER: REVISION NUMBER: THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED. NOTWITHSTANDING ANY REQUIREMENT, TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN, THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CONDITIONS OF SUCH POLICIES.LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS. INSR TYPE OF INSURANCE ADDL SUBR POLICY NUMBER POLICY EFF POLICY EXPINSD MM LIMITS A X COMMERCIAL GENERAL LIABILITY EACH OCCURRENCE 1,000,000 CLAIMS-MADE FX]OCCUR 6DO2139 3/20/2019 3/20/2020 DAMAGE TO RENTED moel $ 500,000 MED EXP(Any one arson $ 10,000 PERSONAL&ADV INJURY $ 1,000,000 GEN'L AGGREGATE LIMIT APPLIES PER: GENERAL AGGREGATE $ 2,000,000 POLICY ElJECT LOC PRODUCTS-COMP/OP AGG $ 2,000,000 OTHER: $ A COMBINED SINGLE LIMIT 1,000,000 AUTOMOBILE LIABILITY $ ANY AUTO 6Z02139 3/20/2019 3/20/2020 BODILY INJURY Perperson) OWNED SCHEDULED AUTOS ONLY Ix AUUTNOSSWNE BODILY INJURY Per accidentXAUTOS ONLY AUTOS ONLDY P�2e0Rd�t AMAGE A X UMBRELLA LIAB X OCCUR EACH OCCURRENCE 5,000,000 EXCESS LIAB CLAIMS-MADE 6JO2139 3/20/2019 3/20/2020 AGGREGATE $ 5'000'000 DED I X I RETENTION$ 10,000 $ B WORKERS COMPENSATION PER OTH- AND EMPLOYERS'LIABILITY R2WC014523 4/3/2019 4/3/2020 1,000,000 ANY PROPRIETOR/PARTNER/EXECUTIVE ( Y� E.L EACH ACCIDENT $ FICER/MEMBER EXCLUDED? N/A (Mandatory in NH) E.L.DISEASE-EA EMPLOYEE $ 1,000,000 If Yes,describe under 1,000,000 DESCRIPTION OF OPERATIONS below E.L.DISEASE-POLICY LIMIT DESCRIPTION OF OPERATIONS/LOCATIONS/VEHICLES (ACORD 101,Additional Remarks Schedule,may be attached if more space is required) CERTIFICATE HOLDER CANCELLATION SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE For Informational Purposes THE EXPIRATION DATE THEREOF, NOTICE WILL BE DELIVERED IN P ACCORDANCE WITH THE POLICY PROVISIONS. Only AUTHORIZED REPRESENTATIVE 3 ACORD 25(2016/03) ©1988-2015 ACORD CORPORATION. All rights reserved. The ACORD name and logo are registered marks of ACORD Richard B. Gordon, P,E. P.O. Box 264911l'arrrivilleeVA 23901 Phe 434.394.2326•E-mail: grichardpe@aol.com July 29,2019 Northampton(Hampshire County)Building Dept. Northampton (Hampshire County),MA Re: Solar Electric Panels Roof Structural Framing Support To th.Bhom it May Concern: i hereby certify that I am a Licensed Professional Engineer in the State of Massachusetts. Please note the following conclusions regarding framing structure,roof loading,and proposed site location of installation: 1. Existing roof framing: Conventional wood framing 2x6 at 24"o.c.with approximate 13'-4"span (horizontal rafter projection). This existing structure is definitely capable to support all of the loads that are indicated below for this photovoltaic project after sister rafters with a 2x6 full length end bearing to end bearing using Paslode 650649 or Paslode 650647(2)10d nails V o.c. Use also adhesive such as Loctite PL or Liquid Nails LN907 or LN903 lova V®C,between the rafter and the member used to sister. Sister required only at those rafters that have rail a nchors mounted into them. 2. Roof Loadinq 0 2.85 psf dead load (modules plus all mounting hardware) 0 24 psf snow live load(40 psf ground snow live load reference) 0 6.26 psf dead load roof materials with 2x6 sister(1.13 psf 2x6 at 24"©,c.,1.5 psf wood sheathing,2.6 psf asphalt shingles) 0 Exposure Category B, 118 mph wind uplift live load of 20.57 psf(wi]nd resistance) 3. Address of proposed installation: Residence of Shotland.168 Crescent ST.)Northampton,MA 01060 'his installation design will be in general conformance to the manufacturer's specifications,and is in compliance with all applicable laws,codes,and ordinances,and specifically, International Residential Code/ IRC 2015. The spacing and fastening of the mounting brackets is to have a maximum of 48"o.c.between mounting brackets and secured using 5/16"diameter corrosive resistant steel lag bolts. In order to evenly distribute the load across the roof rafters,there shall be a minimum of 2 mounting brackets per rafter&min. 2'/:" penetration of lag bolt per bracket,which is adequate to resist all 118 mph wind live Icads including wind shear. Modules installed within 18"of ridge and perimeter of roof is to have 3"anchor penetration. Very truly yours, µOFM SS r ® R,CHA ° a ELECTRICAL FCMRt+ICA �C N�INEERING at �' wO X1193 4r �Fc, ti`�� CIVIL s,e � ENGINEERING t� Rchard B.Gordon, P.E. MA. P.E. Lic.#43393 P.E. Lic. Exp.date: 06-30-2020 Civil, Mechanical,&Electrical Engineering lrule DEVLIN CONTRACTING & IV AINTEN414 ANCE 86 Finnell Dr#21 Weymouth, MAl 02188 P: 7:;1-8 12-0240 F: 781-012.-0319 Homeowner°s Agent Autha dzaWn Form State of Massachusetts wnd a (print name) am the owner of the property Borated at a&J-ess: (print address) D hereby/ autharrfte DeOn Gontracfing and MainAenance, ffac to act as my Agent for the Urnited purpose of appy ging for and obtaining ioca8 building and , other permits from the Authority Having Jurisdiction as requi ed for the instaBlation of a PhotoVOtaic System located on my Property, Customer Signature: Date- � �G Print Name: ,r A B C D E F G H GENERAL NOTES SHEET LIST TABLE �/ twi 1 1.1.1 PROJECT NOTES: NEW PV SYSTEM: 4.225 kWp SHEETNIAfER SHEET TITLE DE Y LILY 11.2 THIS PHOTOVOLTAIC T-00, COVER PAGE �������,,,•��s�.:.•MN<, (F/)SYSTEM SFWL COMPLY WITH THE NATIONAL CODE(NEC)ARTICLE eilI ACTLISTING AND INSTALLATION INSTRUCTIONS AND THE RELEVANT CODES AS SPECIFIED G-001 NOTES BYTEAUTHORITY HAVING JURSDICTION'S(AHJ)APPLICABLE CODES. SHOTLANd RESIDENCE A-101 SITE PLAN 1.1.3 THE UTILITY INTERCONNECTION APPLICATION MUST BE APPROVED AND PV SYSTEM INSPECTED PRIOR TO PARALLEL OPERATION 168 CRESCENT ST A-102 ELECTRICAL PLAN CONTRACTOR 1.1.4 GROUND FAULT DETECTION AND INTERRUPTION (GFDn DEVICE IS X103 SOLAR ATTACHMENT PLAN INTEGRATED WITH THE MCROINVERTER IN ACCORDANCE WITH NEC DEVLIN CONTRACTING AND 6LL P NORTHAMPTON MA 01060 Ems' DESIGNTNE BLE MAINTENANCE,INC 2 1.1.5 ALL PV SYSTEM COMPONENTS; MODULES, UTILITY-INIERACTIVf 1 E-602 DESIGN TABLES INVERTERS,AND SOURCE CIRCUIT COMBINER BOXES ARE IDENTIFIED ANDLISTED FOR Q Q PV MODULES UL11103HIEC6173DAIND EC612 SYSTEMS A70CLASSCFS REQUIRED BY NEC IRE ASSESSOR'S#: NHAMM:024DE.0288L:0001 E-603 PLACARDS PHONE: 781.8120240 INVERTERS:UL 1741 CERTIFIED,IEEE 1547,929,519 S-501 ASSEMBLY DETAILS ADDRESS:86 FINNELL DR#21 COMBINER BOX(ES):UL 1703 OR UL 1741 ACCESSORY R-001 RESOURCE DOCUMENT WEYMOUTH,MA 02188 1.16 MAX DC VOLTAGE CALCULATED USING MANUFACTURER PROVIDED TEMP LIC.NO.: COEFFICIENT FOR VOC.IF UNAVAILABLE,MAX DC VOLTAGE CALCULATED R-002 RESOURCE DOCUMENT FCC N0: ACCORDING TO NEC 690.7ELE.NO.: R-003 RESOURCE DOCUMENT 1.1.7 ALL INVERTERS,PHOTOVOLTAIC MODULES,PHOTOVOLTAIC PANELS,AND UTAU740WED USE OF TwS SOURCE CIRCUIT COMBINERS INTENDED FOR USE IN A PHOTOVOLTAIC R-004 RESOURCE DOCUMENT ORAWNGSETWTHOUTMMEH PEWASSON FROM CONTRACTOR IS IN POWER SYSTEM WILL BE IDENTIFIED AND LISTED FOR THE APPLICATION R-005 RESOURCE DOCUMENT VIOLATIONOF u S CONRIGHT UWS PER 690.4(D).SHALL BE INSTALLED ACCORDING TO ANY INSTRUCTIONS �`:., ANA suSO �OCIIML 3 FROM LISTING OR LABELING INEC 110.31. R-006 RESOURCE DOCUMENT ONS 1.1.8 ALL SIGNAGE TO BE PLACED IN ACCORDANCE WITH LOCAL BUILDING NEW PV SYSTEM:4.225 kWp CODE. IF EXPOSED TO SUNLIGHT,IT SHALL BE UY RESISTANT.ALL PLAQUES AND SIGNAGE WILL BE INSTALLED AS REQUIRED BY THE NEC SH OT LAN D AND AHJ PROJECT INFORMATION 1.2.1 SCOPE OF WORK: RESIDENCE 1.2.2 PRIME CONTRACTOROWNER IS RESPONSIBLE FOR THE DESIGN AND NAME: JEFF SHOTLAND SPECIFICATIONS OF THE GRID-TIED PHOTOVOLTAIC SYSTEM RETROFIT. 168 CRESCENT ST PRIME CONTRACTOR WILL BE RESPONSIBLE FOR COLLECTING EXISTING PROJECTIANAGER NORTHAMPTON,MA 01060 ONSITE REQUIREMENTS TO DESIGN, SPECIFY, AND INSTALL THE EXTERIOR ROOFMOUNTED PORTION OF THE PHOTOVOLTAIC SYSTEMS AERIAL PHOTO NAMENE. APN PHOOENE: 7619e6-9e00 4 DETAILED IN THIS DOCUMENT. 01 NHAMM:024DB:0288L:0001 NOT TO SCALE CONTRACTOR 13.1 WORK INCLUDES: ENGINEER OF RECORD NAME: DEVUNCONTRACTING AND 13.2 PV ROOF ATTACHMENTS-UNIRAC FLAT FLASHING 1.3.3 PV RACKING SYSTEM INSTALLATION-UNIRACSTANDARD MAINTENANCE,INC PHONE: 781.812-0240 1.34 PV MODULE AND INVERTER INSTALLATION-HANWHAQ-CELLS tsi Q.PEAK DUO-G5 3251 ENPHASE 1Q7-60.2-US SAN 1.3.5 PV EQUIPMENTGROINDING AUTHORIIESHAVING JURISDICTION BUILDING 1.3.6 PV SYSTEM WIRING TO A ROOF-MOUNTED JUNC TION BOX HACOUNTY ,.3.7 PV LOAD CENTERS(IF INCLUDED) ZONING FtAWSHIRE MPSHIRE COUNTY 1.3.8 PV METERINCA"ITORING(IF INCLUDED) /�/ �>, UTllltt- 1.3.9 PVDISCONNECTS C\ \ DESIGN SFECIFICATIONS 1.3.10 PV GROUNDING ELECTRODE 8 BONDING TO(E)GEC r, 5 13.11 PV FINAL COMMISSIONING `� OONSTRU. II PAPER SIZE ll'v tl'IANSI BI 1.3.12(E)ELECTRICAL EQUIPMENT RETROFIT FOR PV ZONING: IC+! SNGLENTIALY 13.13 SIGNAGE PLACED IN ACCORDANCE WITH LOCAL BUILDING CODE \ ZONING: RESIDENTIAL COVER PAGE �� GROUND SkOV!L".AD 49PSF WIND SCOPE OF WORK �� \\ WIND SPE CU.4E. 818 MPH DATE: 112.2019 SYSTEM SIZE. STC:13025W=4225kW /\ DESIGN 8Y:MC. PTC.131300.7W=3.909kW DC APPLICABLE CODES 8 STANDARDS (13)HANNMAQ-CELLSOPEAKDUO-G5325 �� BUILDING MASSACHUSETTS RESIDENTIAL CHECKED BY: M.M (13)ENPHASE IQ7-60-2-US mN BUILDING CODE,9TH EDITION,AS 6 ATTACHMENT TYPE. UNIRAC FLAT FLASHING 02 ��t�MAP WTE ELECTRICAL NNEC 20DQBO CMR) REVISIONS FIRE: MASSACHUSETTS COMPREHENSIVE T-001.00 MSP UPGRADE NO I S FRE SAFETY CODE(527 CMR 1.00) A m 8 C 0 E F G H (SHEET 1) A 8 C D E F G 2.1.1 SITE NOTES: 4.5.1 GROUNDING NOTES: 2.1.2 A LADDER WILL BE IN PLACE FOR INSPECTION IN COMPLIANCE WITH OSHA 2.5.2 GROUNDING SYSTEM COMPONENTS SHALL BE LISTED FOR THEIR PURPOSE, REGULATIONS. AND GROUNDING DEVISES EXPOSED TO THE ELEMENTS SHALL BE RATED FOR D E V L I N 1 21.3 THE PV MODULES ARE CONSIDERED NON-COMBUSTIBLE AND THIS SYSTEM IS SUCH USE. [bITIM1G,p6A WLN,ENatxCE A UTILITY INTERACTIVE SYSTEM WITH NO STORAGE BATTERIES. 2.5.3 PV EQUIPMENT SHALL BE GROUNDED ACCORDING TO NEC 690.43 AND 2.1.4 THE SOLAR PV INSTALLATION WILL NOT OBSTRUCT ANY PLUMBING, MINIMUM NEC TABLE 250.122. MECHANICAL,OR BUILDING ROOF VENTS. 2.5.4 METAL PARTS OF MODULE FRAMES,MODULE RACKING,AND ENCLOSURES 215 PROPER ACCESS AND WORKING CLEARANCE AROUND EXISTING AND CONSIDERED GROUNDED IN ACCORD WITH 250.134 AND 250.136(A). PROPOSED ELECTRICAL EQUIPMENT WILL BE PROVIDED AS PER SECTION NEC 2.5.5 EQUIPMENT GROUNDING CONDUCTORS SHALL BE SIZED ACCORDING TO NEC 110.26, 690.45 AND MICROINVERTER MANUFACTORERS'INSTRUCTIONS. CONTRACTOR 2.1.6 ROOF COVERINGS SHALL BE DESIGNED, INSTALLED,AND MAINTAINED IN 2.5.6 EACH MODULE WILL BE GROUNDED USING WEER GROUNDING CLIPS AS ACCORDANCE WITH THIS CODE AND THE APPROVED MANUFACTURER'S SHOWN IN MANUFACTURER DOCUMENTATION AND APPROVED BY THE AHJ. IF DEVUN CONTRACTING AND 2 INSTRUCTIONS SUCH THAT THE ROOF COVERING SERVES TO PROTECT THE WEEBS ARE NOT USED,MODULE GROUNDING LUGS MUST BE INSTALLED AT MAINTENANCE,INC BUILDING OR STRUCTURE. THE SPECIFIED GROUNDING LUG HOLES PER THE MANUFACTURERS' INSTALLATION REQUIREMENTS. 2.21 EQUIPMENT LOCATIONS: 2 5 THE GROUNDING CONNECTION TO A MODULE SHALL BE ARRANGED SUCH PHONE: 781-812-0240 2.2.2. ALL EQUIPMENT SHALL MEET MINIMUM SETBACKS AS REQUIRED BY NEC THAT THE REMOVAL OF A MODULE DOES NOT INTERRUPT A GROUNDING ADDRESS:86 FINNELL DR 421 110.26. CONDUCTOR TO ANOTHER MODULE. WEYMOUTH,MA 02188 2.2.3 WIRING SYSTEMS INSTALLED IN DIRECT SUNLIGHT MUST BE RATED FOR 25.8 GROUNDING AND BONDING CONDUCTORS,IF INSULATED,SHALL BE COLORED EXPECTED OPERATING TEMPERATURE AS SPECIFIED BY NEC 690.31(A),(C) GREEN OR MARKED GREEN IF#4 AWG OR LARGER[NEC 250.119) LIC.NO.: AND NEC TABLES 310.15(B)(2)(A)AND 310.15(8)(3)(C). 2.5.9 THE GROUNDING ELECTRODE SYSTEM COMPLIES WITH NEC 690.47 AND NEC HIC.NO.: 2.24 JUNCTION AND PULL BOXES PERMITTED INSTALLED UNDER PV MODULES 250.50 THROUGH 250.106. IF EXISTING SYSTEM IS INACCESSIBLE, OR ELE.NO.: ACCORDING TO NEC 690.34, INADEQUATE,A GROUNDING ELECTRODE SYSTEM PROVIDED ACCORDING TO UNAUINORVED USE OF THIS DRAAING SET AITNOUTARITTEN 2.2.5 ADDITIONAL AC DISCONNECT(S)SHALL BE PROVIDED WHERE THE INVERTER NEC 250,NEC 690.47 AND AHJ. PERMISSION FROM CONTRACTOR MIN IS NOT WITHIN SIGHT OF THE AC SERVICING DISCONNECT. 2.5.10 GROUND-FAULT DETECTION SHALL COMPLY WITH NEC 690.41(B)(1)AND 2 TO OI TION Of US COPYRIGHT UNG () ANOWU_BE SUBJECT TO CML 3 2.2.6 ALL EQUIPMENT SHALL BE INSTALLED ACCESSIBLE TO QUALIFIED PERSONNEL REDUCE FIRE HAZARDS DAMAGES ANO PROSECUTIONS ACCORDING TO NEC APPLICABLE CODES. 2.2.7 ALL COMPONENTS ARE LISTED FOR THEIR PURPOSE AND RATED FOR 2.6.1 DISCONNECTION AND OVERCURRENT PROTECTION NOTES: NEW PV SYSTEM:4.225 kWp OUTDOOR USAGE WHEN APPROPRIATE. 2.6.2 DISCONNECTING SWITCHES SHALL BE WIRED SUCH THAT WHEN THE SWITCH S H OT LAN D IS OPENED THE CONDUCTORS REMAINING ENERGIZED ARE CONNECTED TO 231 STRUCTURAL NOTES: THE TERMINALS MARKED"LINE SIDE'(TYPICALLY THE UPPER TERMINALS). 2.3.2 RACKING SYSTEM & PV ARRAY WILL BE INSTALLED ACCORDING TO 2.6.3 DISCONNECTS TO BE ACCESSIBLE TO QUALIFIED UTILITY PERSONNEL, BE RESIDENCE CODE-COMPLIANT INSTALLATION MANUAL. TOP CLAMPS REQUIRE A LOCKABLE,AND BE A VISIBLE-BREAK SWITCH DESIGNATED SPACE BETWEEN MODULES,AND RAILS MUST ALSO EXTEND A 2.64 PV SYSTEM CIRCUITS INSTALLED ON OR IN BUILDINGS SHALL INCLUDE A MINIMUM DISTANCE BEYOND EITHER EDGE OF THE ARRAY7SUBARRAY, RAPID SHUTDOWN FUNCTION TO REDUCE SHOCK HAZARD FOR EMERGENCY 168 CRESCENT ST ACCORDING TO RAI MANUFACTURER'S INSTRUCTIONS. RESPONDERS IN ACCORDANCE WITH 690.12(A)THROUGH(D). NORTHAMPTON,MA 01060 2.3.3 JUNCTION BOX WILL BE INSTALLED PER MANUFACTURERS SPECIFICATIONS. 2.6.5 ALL OCPD RATINGS AND TYPES SPECIFIED ACCORDING TO NEC 690.8,690.9, APN: IF ROOF-PENETRATING TYPE,IT SHALL BE FLASHED&SEALED PER LOCAL AND 240. NHAMM:024DB:0288L:0001 4 REQUIREMENTS. 2.6.6 MICROINVERTER BRANCHES CONNECTED TO A SINGLE BREAKER OR 2.3.4 ROOFTOP PENETRATIONS FOR PV RACEWAY WILL BE COMPLETED AND GROUPED FUSES IN ACCORDANCE WITH NEC 110.3(8). ENGINEER OF RECORD SEALED W7 APPROVED CHEMICAL SEALANT PER CODE BY A LICENSED 2.6.7 IF REQUIRED BY AHJ,SYSTEM WILL INCLUDE ARC-FAULT CIRCUIT PROTECTION CONTRACTOR. ACCORDING TO NEC 690.11 AND UL1699B. 2.3.5 ALL PV RELATED ROOF ATTACHMENTS TO BE SPACED NO GREATER THAN THE SPAN DISTANCE SPECIFIED BY THE RACKING MANUFACTURER. 2.7.1 INTERCONNECTION NOTES: 2 1 WHEN POSSIBLE, ALL PV RELATED RACKING ATTACHMENTS WILL BE 2.7.2 LOAD-SIDE INTERCONNECTION SHALL BE IN ACCORDANCE WITH(NEC 705.12 STAGGERED AMONGST THE ROOF FRAMING MEMBERS. (B)] 2.1.3 THE SUM OF THE UTILITY OCPD AND INVERTER CONTINUOUS OUTPUT MAY 241 WIRING&CONDUIT NOTES: NOT EXCEED 120%OF BUSBAR RATING[NEC 705.12(0)(2)(3)1. 2.4.2 ALL CONDUIT AND WIRE WILL BE LISTED AND APPROVED FOR THEIR PURPOSE. 2.7.4 THE SUM OF 125 PERCENT OF THE POWER SOURCE(S)OUTPUT CIRCUIT CONDUIT AND WIRE SPECIFICATIONS ARE BASED ON MINIMUM CODE CURRENT AND THE RATING OF THE OVERCURRENT DEVICE PROTECTING THE REQUIREMENTS AND ARE NOT MEANT TO LIMIT UP-SIZING. BUSBAR SHALL NOT EXCEED 120 PERCENT OF THE AMPACITY OF THE 5 2.4.3 CONDUCTORS SIZED ACCORDING TO NEC 690 8,NEC 690.7 BUSBAR,PV DEDICATED BACKFEED BREAKERS MUST BE LOCATED OPPOSITE PAPER s¢E.11',Ir MSI u 24A VOLTAGE DROP LIMITED TO 1.5% END OF THE BUS FROM THE UTILITY SOURCE OCPO[NEC 705.12(13)(2)(3)]. NOTES 245 DC WIRING LIMITED TO MODULE FOOTPRINT MICROINVERTER WIRING 2.7.5 AT MULTIPLE ELECTRIC POWER SOURCES OUTPUT COMBINER PANEL,TOTAL SYSTEMS SHALL BE LOCATED AND SECURED UNDER THE ARRAY W7 SUITABLE RATING OF ALL OVERCURRENT DEVICES SHALL NOT EXCEED AMPACITY OF WIRING CLIPS. BUSBAR. HOWEVER, THE COMBINED OVERCURRENT DEVICE MAY BE DATE: 7.12.2019 2 4 6 AC CONDUCTORS COLORED OR MARKED AS FOLLOWS EXCLUDED ACCORDING TO NEC 705.12(B)(2)(3)(C). DESIGN BY:MC. PHASE A OR Li-BLACK 2.7.6 FEEDER TAP INTERCONECTION (LOAD SIDE)ACCORDING TO NEC 705.12 PHASE B OR L2-RED,OR OTHER CONVENTION IF THREE PHASE (13)(2)(1) CHECKED BY: MM. PHASE C OR L3-BLUE,YELLOW,ORANGE",OR OTHER CONVENTION 2.7.7 SUPPLY SIDE TAP INTERCONNECTION ACCORDING TO NEC 705.12(A)WITH NEUTRAL-WHITE OR GREY SERVICE ENTRANCE CONDUCTORS IN ACCORDANCE WITH NEC 230.42 REVISIONS 6 IN 4-WIRE DELTA CONNECTED SYSTEMS THE PHASE WITH HIGHER VOLTAGE 2.7.8 BACKFEEDING BREAKER FOR ELECTRIC POWER SOURCES OUTPUT IS EXEMPT TO BE MARKED ORANGE[NEC 110.15] FROM ADDITIONAL FASTENING[NEC 705.12(B)(5)1. G-001.00 1.00 A m B C D E F G r ase-r z z A B C D E F G H GENERAL NOTES ,. FIELD VERIFY ALL MEASUREMENTS J&DE V ILI,N 2, ITEMS BELOW MAY NOT BE ON THIS PAGE ------- PROPERTYLINE CONTRACTOR DEYLIN CONTRACTING AND 2 GRESG�NI S� MAINTENANCE,INC PHONE: 781-812 0 24 0 ADDRESS:86 FINNELL DR#21 WEYMOUTH,MA 02188 LIC.NO.: HIC.NO.: i ELE.NO.: UNAUTH IZED VIWT1 Of U SsC OF RIG DRAWING SET WTHOUT MMEN PERMISSION FROM CONTRACTOR IS IN \ YIO ANO W LL OF U 5 COPYRIGHT UN5 3 DANUGES BE SPRIEST U CMS MMAGES AND PgOSECURONS ENTRANCE 27'-0" \ NEW PV SYSTEM:4.225 kWp \ SHOTLAND `� 1910 RESIDENCE .\ 168 CRESCENT ST NORTHAMPTON,MA 01060 APN: 4 \ �,\ \ NHAMM:024DB:0288L:0001 acLOAD cENrER ` . ENGINEER OF RECORD MA SMART GENERATION METER \ AC CISCON ECT \` LIIILITY AETER 8'-8' AREA OF WORK \ \ 38'-0'I 5 \ PAPERwE ii-or1AN.4W \ SITE PLAN DATE: 1.12.2019 DESIGN BY:MC CHECKED BY: MM SITE PLAN " 8 REVISIONS j7 W E ,N6•_,.r ® 5 A-101.00 A B C D E F G H ,SET 31 A B C D E F G H GENERAL NOTES 1 1 FIELD VERIFY ALL MEASUREMENTS �t D E V L I N 2. ITEMS BELOW MAY NOT BE ON THIS PAGE covruwc+mcs uwN+x:w.0 A MODULE STRINGING CONTRACTOR DEVLIN CONTRACTING AND 2 ARRAY 2-0.975 kW MAINTENANCE,INC N31 IN)MODULES TILT 34 DEGREES - ROOF PITCH.8.12 AZIMUTH-61 DEGREES PHONE: 781.812.0240 ADDRESS:86 FINNELL DR 921 WEYMOUTH,MA 02188 LIC.NO.: HIC.NO.: ELE.NO.: INTERIOR PV EQUIPMENT UNAUTHORZED USE GF THIS (E)(1)MAIN ELECTRICAL PANEL PEA NGSETWTHOUTM17EN RMISSION FROM CONTRACTOR IS IN /� ND TIW OF U S COPYRIGHT UYb 3 A �,.A 7 ( A i M SANOUPO CUTCIONS NEW PV SYSTEM:4.225 kWp SHOTLAND O v RESIDENCE (N)(1)JUNCTION BOX � A O O 168 CRESCENT ST L J Li' NORTHAMPTON,MA 01060 o ARRAY 13258 kW (x10(N)MODULES APN 4 G TILT 34 DEGREES NHAMM:024DB:0288L:0001 ROOF PITCH 8:12 AZIMUTH 241 DEGREES ENGINEER OF RECORD EXTERIOR PV EQUIPMENT (E)(1)UTILITY METER M(1)AC DISCONNECT PA(1)MA SMART GENERATION METER Q'A(1)AC LOAD CENTER 5 PAPER SUE ir.Ir PAS191 ELECTRICAL PLAN 39.4" DATE: 7.121019 DESIGN BY:MC. MODULE CHECKED B Y: M.M.HANWHAQ-CELLS REVISIONS s ELECTRICAL PLAN 663" Q.PEAK DUO-G5 325o D® y ( 325 WATTS 3 L A-102.00 A B C D E F mG H ISHEETn B C D E F G H GENERAL NOTEv 1. FIELD VERIFY ALL MEASUREMENTS DEVLIN 2. ITEMS BELOW MAY NOT BE ON THIS PAGE c-a^^�,�^�•..�.N,..<L.I ——— ROOF RAFTERS CONTRACTOR DEVLIN CONTRACTING AND 16'-7" MAINTENANCE,INC -- PHONE: 781412-0240 1 I I 1 I 1 1 I I 1 ADDRESS:BB FINNELL DR 121 KYMDUTH,MA 02188 I I 1 I I 1 1 I 1 I LIC.NO.: I 1 1 1 I I I I I I 1 I 1 I 1 HIC.NO.: I 1 I I I I I I 1 (I 1 1 I 1 I 1 ELE,NO.: 1 1 1 1 I 1 I I I I I I I I 1 I UNAUTPORM USE OF THIS ORAWNGSETWTHOUTARITTEN I 1 I I I I I 1 I I 1 1 PERMISSION FROM CONTRACTOR IS IN 1 I 1 I I I I I MIX TION OF u S COPYRIGHT UMB I 1 1 I I 1 1 I I I 1 I I I I I MA ESANDPROSECUT10115 1 I 1 I 1 1 I I 1 I I I I I 1 I 1 1 1 1 I 1 I 1 I 1 I 1 NEW PV SYSTEM:4.225 kWp I 1 I 1 1 I I I 1 1 I 1 I I 1 1 SHOTLAND ' d. !. a ' FLUSH MOUNT SQL.-R MODULE: RESIDENCE _r -I IED Y 1 - r- f I 1 I -t I .'.TT,1�ED TO ROOF SURfX',E GE 1 -♦ -. - __I._.1-_ 1-. L 1- ♦ I SHEET S 501 FOR MOUNTING rf-±IS; ' — 168 CRESCENT ST 1 1 I, ROOF MpTERV115 2LAYER.SHt=_T`wI+GLE NORTHAMPTON,MA 01060 I I 1 I T I 1 I I 1 I 1 1 I p l I 1 I I I I LPN: ' NHAMM:024DB:0288L:0001 2T-9" ENGINEER OF RECORD I-- -�1 Richard B.Gordon,P.E. MA.P E Llc.#49993 E.LIc.Exp.date 06-30-2020 Cml,Mechanical,&Electrical Engineering ELECTRICAL `:GINEERINo LML yy•'"STs/° ENGNEERING vi7T� PAPER 92E IV,1 r IANSI III ,July 29,2019 SOLAR ATTACHMENT PLAN 39.4" DATE: 712.2019 DF14GN BY M MODULE. CHECKED BY: MM NWHA 6 SOLAR ATTACHMENT PLAN 56 3" Q.PEAK WAQ-CELLS REVISIONS 01 va^=r o® a 5 I 5TTS0-G5325 A-103,00 B - C D E F L G H (SIE ET5) A B C D E F G H CONDUCTOR AND CONDUIT SCHEDULE W/ELECTRICAL CALCULATIONS CURRENT-CARRYING CONDUCTORS ID TYPICAL CONDUCTOR CONDUIT OCPD EGC TEMP CORR.FACTOR CONDUIT FILL FACTOR CONT CURRENT MAX CURRENT(125%) BASEAMP C--�rTEJAMP TERM TEMP RATING AMP TERMINAL ®���'� N CONDUIT 101 1 tOAWG THWN2,COPPER 0.5'DIAEMT 2 20A 8AWG THWN-2,COPPER 076(547'C) 1 13A 1625A 40A i0 a> 75°C 35A 02 1 10 AWG THWN-2,COPPER 05'DIA EMT 2 N/A 8AWG THWN-2,COPPER 096(32.7-C) 1 13A 1625A 40A ill'A 75'C 35A 1 10 A'NG TIT.RN-2,COPPCR 05'ulA EM7 WA 0AWG T!WN-2,COPPC: 0.96(327-C) 13A 40A :8„ A 7 10AWGTHWN-2,COPPER 05"CIA EMT 2 20A 8AWG THWN-2.COPPER 0.96(327-C) 1 13A 1625A 40A 58'A 75'C 35A A MODULE STRINGING CONTRACTOR DEVLIN CONTRACTING AND 2 MAINTENANCE.INC MAIN SERVICE PANEL 60A LOAD CENTER TO UTILITY 240/120 V 10 3VV PHONE: 781812.0240 120/240V,10,3W GRID(OH) MAIN BUSS:100A ADDRESS:86 FINNELL DR#21 MAX.CONTINUOUS CURRENT:48A A A A� MAX BREAKER SIZE PrEYMOUTH,MA 02188 MAX.OCPD:60A (100A x 1.2)-100A=20A LIC.No.: HIC.NO.: L1 ELE.NO.: UNAUTHORIZED USE OF THIS ENPHASE ENVOY N DRAWNGSET WTHOUTnwTTEN 1. PV SYSTEM EQUIPEED WITH COMMUNICATIONS L2 VIO TIONOOF FROM cowRCCHT uWb" GATEWAY DA"AIIIAGEGES ANOU�ECuroNS 3 RAPID SHUTDOWN 2, SYSTEM COMPLIANT WITH NEW PV SYSTEM:4.225 kWp NEC 690.12. (E)120V OUTLET i (E) SH®TLAND UTILITY L EE METER RESIDENCE 168 CRESCENT ST 5A GROUND MA SMART AC DISCONNECT ROD NORTHAMPTON,MA 01060 ® ADN GENERATION 30A 4 METER —� NHAMM:024D8:0288L:0001 L (E)GROUNDING ENGINEER OF RECORD N ELECTRODE ENPHASE (E)MAIN IQ7-60-2-US TOP LUGS 100A - - - - — 01 A 1 20A oz 03 oa N (N) IT TO(E) 13 20A/2P LOADS IN BRANCH RED L2 B ACR 6 L1 PAPER WE tt'v 17'(ANSI BI L1N L2' . - — LINE DIAGRAM HANWHA Q-CELLS JUNCTION BOX LOAD LINE DATE: 712.2019 Q.PEAK DUO-G5 325 EQUIPMENT LEFT ! EQUIPMENT RIGHT 325W LINE IS(N)NEW LINE IS(E)EXISTING DESIGN BY MC BOTTOM LUGS UNLESS OTHERWISE NOTED CHECKED BY: MM. REVfSIONS 6 E-601.00 A B C D E F G H (SHEETS) A B C D E F G H D,EVLIN SYSTEM SUMMARY MODULES BRANCH pt REF QTY MANE AND MODEL PMAX PTC ISC IMP VOC VMP TEMP COEFF.OF VOC FUSE RATING INVERTERS PER BRANCH 13 PM" 13 HANWHA QCElL80 PEAK DUO-G5325 325W 300.7W 10.14A 42 40.4V 3365V 10113VPC(-0.28%/'C) 20A MAX AC CURRENT 134 MAX AC OUTPUT POWER 3,25OW INVERTERS CONTRACTOR ARRAY STC POWER 4,225W DCPD MAX OUTPUT MAX INPUT CEC WEIGHTED ARRAY PTC POWER 3,909W REFMll MAKE AND MODEL AC VOLTAGE GROUND RATING RATED POWER CURRENT CURRENT INPUTVOLTAG EFFICIENCY DEVLIN CONTRACTING AND 2 MAX AC CURRENT 134 11-1ENPHASE 107-602-US 240V FLOATING 20A I 24OW I 1A 15A I 48V 1 970% MAINTENANCE,INC MAX AC POWER 3,25OW DERATED(CEC)AC POWER 3,25OW DISCONNECTS OCPDS REF.QTY MAKE AND MODEL RATED CURRENT MAX RATED VOLTAGE REF I OTY I RATED CURRENT MAX VOLTAGE PHONE: 781-812.0240 DESIGN TEMPERATURES L-11 EATON OG221URB OR EQUIV iA- 240VAG CB 1,3 2 20A 240VAG ADDRESS:B6 FINNELL OR 021 ASHRAE EXTREME LOW -259-C(-146-F),SOURCE.BARNES MUNI(42.16',-72 72-) CB2 1 SA 240VAC WEYMOUTH,MA 02188 ASHRAE 2%HIGH 321-C(90 9'F),SOURCE BARNES MUNI(42 16',-72 72-) 111 LIC.NO.: HIC.NO.: ELE.NO.: UNAUTHORVEO USE a THIS DRANING SET`MTHOUT MITTEN BILL OF MATERIALS Haunon as uGS COM cin LIMNS CATEGORY MAKE MODELNUMBER REF OTY UNIT I OTYIUNIT DESCRIPTION ANO IMLL BE SUBJECT TO CIVIL 3 MODULE HANWHA Q-CELLS O.PEAK DUO-G5325 PM!-13 13 PIECES 1 HANWHA Q-CELLS Q.PEAK DUO-G5 325 325W 120 RALF CUT CELLS,MONOCRYSTALLINE SILICON DAMAGES 00 MOSECUnGNS INVERTER ENPHASE 107-60-2-US I1-13 13 PIECES 1 ENPHASE 107-60-2-US240WINVERTER NEW PV SYSTEM:4.225kWp DISCONNECT EATON DG221URB SW1 1 PIECE 1 EATON DG221URB,2-POLE,30A,240VAC OR EQUIVALENT PRODUCTION METER GENERIC MANUFACTURER GEN-METER-80A Mi 1 PIECE 1 MA SMART GENERATION METER SHOTLAND MISC ELECTRICAL EQUIPMENT GEN-CABLE-CLIP HDWRi6-01 65 PIECES 1 GENERIC CABLE CLIP AC COMBINER PANEL ENPHASE IO PANEL EP1 1 PIECE 1 ENPHASE IQ COMBINER(X.10-AMl-240-B) MONITORING ENPHASEENVOYENV! 1 PIECE 1 ENPHASE ENVOY RESIDENCE WIRING ENPHASE Q-12-17-240 ENI 13 13 PIECES 1 ENPHASE ENGAGE(TM)TRUNK CABLE FOR 60 CELLS MODULE LANDSCAPE LAYOUT HARING ENPHASE GTERM-10 EN14 1 BUNDLE 10 ENPHASE ENGAGE(TM)BRANCH TERMINATOR WIRING ENPHASE GSEAL-10 EN15 1 BUNDLE 10 ENPHASE ENGAGE(TM)WATERTIGHT SEXING CAP 168 CRESCENT ST WIRING GEN40-AWG-THWN-2-CURD WRIA 90 FEET 1 10 AWGTHWR-2,COPPER RED(LINE 1) NORTHAMPTON,MA 01060 WIRING GEN-I0-AWG-THWN-2CU-BLK WR1-4 90 FEET 1 10AWGTHWTI-2,COPPER,BLACK(LINE 2) APN: WIRING GEN.10AWGTHWN-2-CU-WH WR2.4 50 FEET 1 10 AWG THWN-2,COPPER WHITE(NEUTRAL) 4 WIRING GEN8AWG-THWN-2CU-GR WR1-4 90 FEET 1 8AWG THWN-2,COPPER,GREEN(GROUND) NHAMM:024DB:0288L:0001 WIREWAY ENPHASE ET-SPLK-05 EN16 1 BUNDLE 5 ENPHASE ENGAGE(TM)ENGAGE COUPLER WREWAY GEN-EMT-0-501A WW1 90 FEET 1EMT CONDUIT,05'DIA ENGINEER OF RECORD OCPD GENERIC MANUFACTURER GEN-CB-20A-240VAC C81,3 2 PIECES 1 CIRCUIT BREAKER,20A 240VAC OCPO GENEPoC MANUFACTURER GEN-CB-SA-240VAC CB2 1 PIECE 1 CIRCUIT BREAKER,5A,240VAC TRANSITION BOX GENERIC MANUFACTURER GEN-JB JB1 1 PIECE 1 JUNCTION BOX 5 PAPERSIZE 1J-.1rJAN5JBI DESIGN TABLES DATE: 7.12.2019 DESIGN BY:MC. CHECKED BY: MR REVISIONS 6 E-602.00 A SIT B C D E F GSS H ISNEE I n A B C D E F G H 0 !CAUTION! 0 J&DE LIN POWER TO THIS BUILDING IS ALSO SUPPLIED FROM ROOF MOUNTED SOLAR ARRAYS WITH SAFETY DISCONNECTS AS SHOWN: CONTRACTOR DEAN CONTRACTING AND 2 PVARRAY MAINTENANCE,INC • • MAIN DISTRIBUTION PHONE: 781.812.0240 RAPIDWITH • UTILITY DISCONNECT ADDRESS:86 FINNELL DR 121 WEYMOUTH,MA 02188 FRONT BACK TURN RAPID SHUTDOWN LIC.NO.: LABEL 3 SW1CH TO THE'OFF" HIC.NO.: AT EACH DISCONNECTING MEANS FOR POSITION TO SHUTDOWN PVARRAY ELE.NO.: PHOTOVOLTAIC EQUIPMENT PV SYSTEM AND REDUCE UNAUTHORMED USE of THIS [NEC69013AND690151 SHOCK HAZARD IN ARRAY NTNG SETROTH U N PERMIGLON FROM CONTRACTOR IS IN it NOTAOF TION U S COPYRIGHT UN5 AND WILLBET CML 3 LABEL 1 LABEL 2 � I'V DISCONNECT OAMAGEG ANO DPROSPROGECUTWNG AT RAPID SHUTDOWN SYSTEM AT RAPID SHUTDOWN SYSTEM [NEC 690.56(C)(1)(A)1 (NEC 690.%(C)(1)(B)1. DIRECTORY NEW PV SYSTEM:4.225 kWp PERMANENT PLAQUE OR INTERACTIVE PHOTOVOLTAIC SYSTEM DIRECTORY PROVIDING 0 0SHOTLAND CONNECTED SERVICE THE LOCATION OF THE 10 0 PHOTOVOLTAIC SYSTEM DISCONNECT LOCATED DISCONNECTING MEANS RESIDENCE SW SIDE OF THE HOUSE AND THE PHOTOVOLTAIC LABELS LABEL? PLAQUE SYSTEM DISCONNECTING 168 CRESCENT ST MEANS IF NOT IN THE AT POINT OF INTERCONNECTION,LABEL.SUCH AS LABEL 5 OR LABEL 6 MUST IDENTIFY SAME LOCATION NORTHAMPTON,MA 01060 PHOTOVOLTAIC SYSTEM [NEC 690.56(B)1 (NEC 70512(B)(4)1 WHERE THE PV SYSTEMS APN: 4PHOTOVOLTAIC ARE REMOTELY LOCATED NHAMM:024DB:0288L:0001 SYSQ INTERACTIVE PHOTOVOLTAIC SYSTEM o o AC DISCONNECT a PHOTOVOLTAIC EQUIPPED RAPID DIR EOM CTORY INEACH A ENGINEER OF RECORD CONNECTED ACCORDANCE WITH 70510 OPERATING CURRENT TTA AC SHUTDOWN SHALL BE PROVIDED AT OPERATNO40LTAGE NOVAC EACH PV SYSTEM LABELS LABELS LABEL 10 DISCONNECTING MEANS AT UTILITY METER AT POINT OF INTERCONNECTION,MARKED AT RAPID SHUTDOWN SNATCH PV SYSTEM EQUIPMENT [NEC 690 56(8)1 AT DISCONNECTING MEANS [NEC 690 56(C)1 AND DISCONNECTING [NEC 690.541 LETTERS AT LEAST 3/8 INCH,WHITE ON RED MEANS SHALL NOT BE BACKGROUND,REFLECTIVE INSTALLED IN BATHROOMS FC 80511.1.1 [NEC 690 4(D),(E)1 lvVARNiNG PHOTOVOLTAIC0 PHOTOVOLTAIC O PAPER SIN Ir,Ir UNO 8) POWER SOURCE AC DISCONNECT PLACARDS LABEL 11 LABEL 12 LABEL 13 AT EXPOSED RACEWAYS,CABLE TRAYS,AND OTHER WIRING AT EACH AC DISCONNECTING MEANS AT POINT OF INTERCONNECTION DATE: 1.12.2019 METHODS,SPACED AT MAXIMUM 10 FT SECTION OR WHERE [NEC 690 13(8)1 OVERCURRENT DEVICE SEPARATED BY ENCLOSURES,WALLS,PARTITIONS,CEILINGS, LABELING NOTES [NEC 7D5 12(6)(2)(3)(8)1 DESIGN BY:MC. OR FLOORS 1 1 LABELING REQUIREMENTS BASED ON THE 2017 NATIONAL ELECTRICAL CODE,INTERNATIONAL FIRE CODE 605 11,OSHA CHECKED BY: MM. (NEC 690 31(G)1 STANDARD 1910145,ANSI Z535 LETTERS AT LEAST 318 INCH,WHITE ON RED BACKGROUND, 12 MATERIAL BASED ON THE REQUIREMENTS OF THE AUTHORITY HAVING JURISDICTION REVISIONS 6 REFLECTIVE 13 LABELS TO BE OF SUFFICIENT DURABILITY TO WITHSTAND THE ENVIRONMENT INVOLVED [IFC 605 11 1 11 14 LABELS TO BE A MINIMUM LETTER HEIGHT OF 318'AND PERMANENTLY AFFIXED 15 ALERTING WORDS TO BE COLOR CODED 'DANGER'WILL HAVE RED BACKGROUND,'WARNING'INCL HAVE ORANGE E�603,00 BACKGROUND,'CAUTION'WLL HAVE YELLOW BACKGROUND[ANSI 25351 A B C D E F G H (SHEET el A B C .-...__..�.--- ---�- —� - E F _. G I H Da 2C _ GENERAL NOTES ryEVLIN VWX .. sot ! 27, 1. FELDVERIFYALL MEASUREMENTS 4 5 B I y 1 23 24 ]5 I ) 11 13 14 \-15&022 --� CONTRACTOR L aVo DEVLIWCONTRACTING AND 2 MAINTENANCE,INC RACKING DETAIL (LONGITUDINAL) I i I 181-812 0240 FD2 I Q SHEET KEYNOTES PHONE: 86FINNELL NOT TO SCALE ADDRESS:86 FINNELL DR#21 1 ROLL MATERIAL ASPHALT SHINGLE WEYMOUTH,MA 02188 2 POU S-RUCTURE COLLAR TIE 3, A74WAENT TYPE UNIRAC FLAT FLASHING LIC.NO.: 4 I,JDCJLE MANUFACTURER-HANWHA Q-CELLS HIC.NO.: 5 M.'CJLE MODEL Q PEAK DUO-G5325 ELE.NO.: RACKING DETAIL (TRANSVERSE) 6 "jLE LENGTH 1IN UNAUTNGSETMIHOUTWI F1 q Sister rafters with a 2x6 full len th end beano So entl beano usln Peslode 650649 Or Paslode 650647 7 MJCJLE WIDTH 391 2 ORANING sEFROMCON WRITTEN 9 ® 9 9 8. MDOJLE WEIGHT 41.2 LBS PERK TON OF U 5 COP iRGHTOR IS S D� NOT TO SCALE (2)10d nails I'D c. Use also adhesive such as Loctite PL or Lpuid Nails LN907 or LN903 low VOID, g SEE SHEET A-103 FOR DIMENSION(S) OVATE BE SUBIECT*Oc VL�WS 3 between the rafter and the member used to sister. Sister required only at those rafters that have rail 10 6JIN FIRE OFFSET NO FIRE CODE ENFORCED 64MAGES AND PROSECUTIONS 10 O9 anchors mounted into them. 11 RAFTER SPE 2XISING NOMIN4 IN 0 AL NEW PV SYSTEM:4.225 kWp 12 RAF BOLTDIAMETEOMINAL --� 13 LAG BOLT DIAMETER.5116 IN 14 U3 SOLT EMBEDMENT 2.1121N ' 15 TOTAL$OF ATTACHMENTS 42 SHOT LAN 10 I 16 TGTAL AREA 235.83 SQ FT 17 TOT A L VPIGHT67112RESIDENCE 18 VEIGHT aER ATTACHMENEN T 1598 LBS 19. DISTRIBUTED LOAD 2 55 PSF 20 WX HORIZONTAL STANDOFF 481N 168 CRESCENT ST 21 NAX•IERTICAL STANDOFF- O LANDSCAPE 31 IN.,PORTRAIT.50 IN NORTHAMPTON,MA 01060 22 Si ANOOFF STAGGERING YES APN: 23RAILMANUFACTURER(OREQUN.).UNIRAC 4 24 PAIL MODEL(OR EQUIVALENT)-STANDARD NHAMM:024DB:0288L:0001 25 RNL WEa;HT.0 728 PLP 26 MAX RAFTER SPAN 1601N ENGINEER OF RECORD 27 MODULE CLEARANCE:3 IN.MIN.61N MAX Richard B Gordon,P.E MA.P E.Llc.#49993 5 P E Lic Exp date. 06-30-2020 D3 RACKING DETAIL (TOP) CivlElectrical Engineneenng NOT TO$DALE ,,c ��LEcrRIcnE N;INEERING CIVIL 5 u �i' i i' ENGINEERING PAPERffiE 11'41r IINSIBI ASSEMBLY DETAILS July 29,2019 DATE: 7,12.2019 I DESIGN BY:MC CHECKED BY: M.M. REVISIONS DETAIL TRANSVERSE [-p-5] DETAIL LONGITUDINAL --- --- D4NOT TO SCALE NOT TO SCALE S-501,00 I A ------_-- 8 -"-' C - D — E-'------7---- f G --B--�-- H (SHEETS) A R C D E F G H GENERAL NOTES NEW PV SYSTEM. 4.225 kW SHEET LIST TABLE ��DEVLINI 1 11.1 PROJECT NOTES: SHEETMAI WET TITLE � N L av,>LNILrw._L 11.2 THIS PHOTOVOLTAIC(PJ)SYSTEM SHALL COMPLY WITH THE NATIONAL T-001 COVER PAGE ELECTRIC CODE(NEC)ARTICLE ALL MANUFACTUREIRS'S LISTING AND INSTALLATION INSTRUCTIOAND THE RELEVANT CODES AS SPECIFIED G-001 NOTES BY THE AUTHOR TYHAVINGJURISDICT)MS(AHJ)APPLICABLECODES. SHOTLAND RESIDENCE A-101 SITE PLAN 11.3 THE UTILITY INTERCONNECTION APPLICATION MUST BE APPROVED AND PV SYSTEM INSPECTED PRIOR TO PARALLEL OPERATION 168 CRESCENT ST X102 ELECTRICAL PIAN CONTRACTOR 1.1.4 GROUND FAULT DETECTION AND INTERRUPTION (GFDI) DEVICE IS X103 SOLAR ATTACHMENT PLAN INTEGRATED WITH THE MICROINVERTER IN ACCORDANCE WITH NEC E-fi01 LINE DIAGRAM DEVLiN CONTRACTING AND 690.41(8) NORTHAMPTON MA 01060 MAINTENANCE,INC 2 1.1.5 ALL PV SYSTEM COMPONENTS; MODULES, UTILITY-INTERACTIVE T E-802 DESIGN TABLES INVERTERS,AND SOURCE CIRCUIT COMBINER BOXES ARE IDENTIFIED AND Q Q LISTED FOR USE IN PHOTOVOLTAIC SYSTEMS AS REQUIRED BY NEC 690.4: ASSESSORI S TI'. NHAMM:024®E.O�BBL.0001 E-603 PLACARDS PHONE: 781-8120240 PV MODULES:UL1703,IEC61730,AND IEC61215,AND NFPA 70 CLASS C FIRE (S-501 ASSEMBLY DETAILS ADDRESS:86 FINNELL DR#21 INVERTERS:UL 1741 CERTIFIED,IEEE 1547,929,519 WEYMOUTH,MA 02188 COMBINER BOX(ES):UL 1703 OR UL 1741 ACCESSORY R-001 RESOURCE DOCUMENT 11.6 MAX DC VOLTAGE CALCULATED USING MANUFACTURER PROVIDED TEMP R-002 RESOURCE DOCUMENT LIC.NO.: COEFFICIENT FOR VOC.IF UNAVAILABLE,MAX DC VOLTAGE CALCULATED HIC.NO.: ACCORDING TO NEC 690.7 R-003 RESOURCE DOCUMENT ELE.NO.: 11.7 ALL INVERTERS,PHOTOVOLTAIC MODULES,PHOTOVOLTAIC PANELS,AND UNAUIRORQEO USE OF THIS R-M RESOURCE DOCUMENT ORANANCSET WITHOUTWRmEN SOURCE CIRCUIT COMBINERS INTENDED FOR USE IN A PHOTOVOLTAIC PERNSSIONFROM CONTRACTOR ISIN POWER SYSTEM WILL BE IDENTIFIED AND LISTED FOR THE APPLICATIONR-0OS RESOURCE DOCUMENT WOLATION OF U S CONRIGHT TANS AND WILL BE SUBJECT TO CML 3 PER 6904(0).SHALL BE INSTALLED ACCORDING TO ANY INSTRUCTIONS OANIGES AND PROSECUTORS FROM LISTING OR LABELING(NEC 110.31. R-II08 RESOURCE DOCUMENT 1.1.8 ALL SIGNAGE TO BE PLACED IN ACCORDANCE WITH LOCAL BUILDING NEW PV SYSTEM:4.225 kWp CODE.IF EXPOSED TO SUNLIGHT,IT SHALL BE UV RESISTANT.ALL PLAQUES AND SIGNAGE WILL BE INSTALLED AS REQUIRED BY THE NEC SH OTLAND ANDAHJ PROJECT INFORMATION 1.21 SCOPE OF WORK: OWNER RESIDENCE 1.2.2 PRIME CONTRACTOR IS RESPONSIBLE FOR THE DESIGN AND NAME: JEFF SHOTLAND SPECIFICATIONS OF THE GRID-TIED PHOTOVOLTAIC SYSTEM RETROFIT. 168 CRESCENT ST PRIME CONTRACTOR WILL BE RESPONSIBLE FOR COLLECTING EXISTING PROJECT9AAAGER NORTHAMPTON,MA 01060 ONSITE REQUIREMENTS TO DESIGN, SPECIFY, AND INSTALL TIE AERIAL PHOTO NAME: CINDYINGEMI APN EXTERIOR ROOF MOUNTED PORTION OF THE PHOTOVOLTAIC SYSTEMS q DETAILED INTHIS DOCUMENT. 01 PHONE: 781-98E9800 NHAMM:024DB:0288L:0001 NOT TO SCALE CONTRACTOR 1.3.1 WORK INCLUDES: NAME: DEVLIN CONTRACTING AND ENGINEER OF RECORD 1.3.2 PV ROOF ATTACHMENTS-UNIRAC FLAT FLASHING MAINTENANCE,INC 1.13 PV RACKING SYSTEM INSTALLATION-UNIRAC STANDARDPHONE: 781812-0240 1.3.4 PV MODULE AND INVERTER INSTALLATION-HANWHAQ-CELLS S� C.PEAK DUO-G5 3251 ENPHASE IQ7-60-2-US AUTHORITIES HAVING JURISDICTION 1.3.5 PV EQUIPMENT GROUNDING BUILDING HAMPSHIRE COUNTY BUILDING 1.3.6 PVSYSTEMWIRING TO A ROOF-MOUNTED JUNCTIONBOX \ B 1.3.7 PV LOAD CENTERS(IF INCLUDED) "\�`\ UTIILIITY HAMPSHIRE COUNTY 1.3.8 PV METERING7MONITORING(IFINCLUDED) ` 1.3.9 PVDISCONNECTS \ DESIGN SPECIFICATIONS 1.3.10 PV GROUNDING ELECTRODE&BONDING TO(E)GEC U OCCUPANC' II 5 1.311 PV FINAL COMMISSIONING `� T� RARERs¢En N+r wal el 1.3.12(E)ELECTRICAL EQUIPMENT RETROFIT FOR PV \ ZONING: N: SINGLENTIALY 1.3.13 SIGNAGE PLACED IN ACCORDANCE WITH LOCAL BUILDING CODE \ ZONING: RESIDENTIAL COVER PAGE GROUND SkOWL^Ap 40PSF MNDEXPoYSLAtE. B DATE: 1.12.2019 SCOPE OF WORK WIND SPEED 118 MPH SYSTEM SIZE. STC:13 z 325W=4 2251W ` > DESIGN BY:MC. PTC:13 z 300.7W=3.909111111 DO APPLICABLE CODES d STANDARDS (13)HANWHAO-CELLS Q.PEAK DUI 325 BUILDING MASSACHUSETTS RESIDENTIAL CHECKED BY: MM. (13)ENPHASE IQ7-60-2-US N BUILDING CODE,9TH EDITION,AS AMENDE6 OL^ PLAT MAP ELECTRICAL NEC201D(IBOCMR) REVISIONS ATTACHMENT TYPE: UNIRAC FLAT FLASHING NOT TO SCALE w( E FIRE: MASSACHUSETTS COMPREHENSIVE T-001.00 MSP UPGRADE NO S FIRE SAFETY CODE(527CMIR1.00) A B C D E F G H (SHEET t) A B C D E F H 2.1 1 SITE NOTES: 4.51 GROUNDING NOTES: 2.1.2 A LADDER WILL BE IN PLACE FOR INSPECTION IN COMPLIANCE VATH OSHA 2.5.2 GROUNDING SYSTEM COMPONENTS SHALL BE LISTED FOR THEIR PURPOSE, REGULATIONS. AND GROUNDING DEVISES EXPOSED TO THE ELEMENTS SHALL BE RATED FOR �t D EVLIN 1 21.3 THE PV MODULES ARE CONSIDERED NON-COMBUSTIBLE AND THIS SYSTEM IS SUCH USE. conriuernea Memru N A UTILITY INTERACTIVE SYSTEM WITH NO STORAGE BATTERIES. 2.5.3 PV EQUIPMENT SHALL BE GROUNDED ACCORDING TO NEC 690.43 AND 2.1.4 THE SOLAR PV INSTALLATION WILL NOT OBSTRUCT ANY PLUMBING, MINIMUM NEC TABLE 250.122 MECHANICAL,OR BUILDING ROOF VENTS. 254 METAL PARTS OF MODULE FRAMES,MODULE RACKING,AND ENCLOSURES 215 PROPER ACCESS AND WORKING CLEARANCE AROUND EXISTING AND CONSIDERED GROUNDED IN ACCORD WITH 250.134 AND 250.136(A). PROPOSED ELECTRICAL EQUIPMENT WILL BE PROVIDED AS PER SECTION NEC 2.5.5 EQUIPMENT GROUNDING CONDUCTORS SHALL BE SIZED ACCORDING TO NEC 110.26. 690.45 AND MICROINVERTER MANUFACTORERSINSTRUCTIONS. CONTRACTOR 2.1.6 ROOF COVERINGS SHALL BE DESIGNED, INSTALLED,AND MAINTAINED IN 2.5.6 EACH MODULE WILL BE GROUNDED USING WEEK GROUNDING CLIPS AS ACCORDANCE WITH THIS CODE AND THE APPROVED MANUFACTURER'S SHOWN IN MANUFACTURER DOCUMENTATION AND APPROVED BY THE AHJ. IF DEVLIN CONTRACTING AND 2 INSTRUCTIONS SUCH THAT THE ROOF COVERING SERVES TO PROTECT THE WEEBS ARE NOT USED,MODULE GROUNDING LUGS MUST BE INSTALLED AT MAINTENANCE,INC BUILDING OR STRUCTURE. THE SPECIFIED GROUNDING LUG HOLES PER THE MANUFACTURERS' INSTALLATION REQUIREMENTS. 22.1 EQUIPMENT LOCATIONS: 25.1 THE GROUNDING CONNECTION TO A MODULE SHALL BE ARRANGED SUCH PHONE: 781-812-0240 2.2.2 ALL EQUIPMENT SHALL MEET MINIMUM SETBACKS AS REQUIRED BY NEC THAT THE REMOVAL OF A MODULE DOES NOT INTERRUPT A GROUNDING AODRESS:85FUELL DR#21 110.26. CONDUCTOR TO ANOTHER MODULE. YrEYMOUTH,MA 02188 2 2.3 WIRING SYSTEMS INSTALLED IN DIRECT SUNLIGHT MUST BE RATED FOR 25.8 GROUNDING AND BONDING CONDUCTORS,IF INSULATED,SHALL BE COLORED EXPECTED OPERATING TEMPERATURE AS SPECIFIED BY NEC 890.31(A),(C) GREEN OR MARKED GREEN IF AM AWG OR LARGER[NEC 250.1191 LIC.NO.: AND NEC TABLES 310.15(B)(2)(A)AND 310.15(13)(3)(C). 25.9 THE GROUNDING ELECTRODE SYSTEM COMPLIES WITH NEC 690.47 AND NEC HIC,NO.: 2.2.4 JUNCTION AND PULL BOXES PERMITTED INSTALLED UNDER PV MODULES 250.50 THROUGH 250.106. IF EXISTING SYSTEM IS INACCESSIBLE, OR ELE.NO.: ACCORDING TO NEC 690.34. INADEQUATE,A GROUNDING ELECTRODE SYSTEM PROVIDED ACCORDING TO UNAUTHORIZED USE OF THIS URAWNG SET WTHOUT MRTTEN 225 ADDITIONAL AC DISCONNECT(S)SHALL BE PROVIDED WHERE THE INVERTER NEC 250,NEC 690.47 AND AHJ. PERMISSION FROM CONTRACTOR ISIN ISNOT WITHIN SIGHT Of THE AC SERVICING DISCONNECT. 2.5.10 GROUND-FAULT DETECTION SHALL COMPLY WITH NEC 690.41(8)(1)AND(2)TO AND WU a SUBJECT TO CML 2.2.6 ALL EQUIPMENT SHALL BE INSTALLED ACCESSIBLE TO QUALIFIED PERSONNEL REDUCE FIRE HAZARDS OAMAGESANDPROSECUTIONS ACCORDING TO NEC APPLICABLE CODES. 2.2.7 ALL COMPONENTS ARE LISTED FOR THEIR PURPOSE AND RATED FOR 2.6.1 DISCONNECTION AND OVER-CURRENT PROTECTION NOTES: NEW PV SYSTEM:4.225 kWp OUTDOOR USAGE WHEN APPROPRIATE. 2.6.2 DISCONNECTING SWITCHES SHALL BE WIRED SUCH THAT WHEN THE SWITCH SH OT LAN D IS OPENED THE CONDUCTORS REMAINING ENERGIZED ARE CONNECTED TO 231 STRUCTURAL NOTES: THE TERMINALS MARKED'LINE SIDE'(TYPICALLY THE UPPER TERMINALS). 23.2 RACKING SYSTEM 8 PV ARRAY WILL BE INSTALLED ACCORDING TO 26.3 DISCONNECTS TO BE ACCESSIBLE TO QUALIFIED UTILITY PERSONNEL, BE RESIDENCE CODE-COMPLIANT INSTALLATION MANUAL. TOP CLAMPS REQUIRE A LOCKABLE,AND BE A VISIBLE-BREAK SWITCH DESIGNATED SPACE BETWEEN MODULES,AND RAILS MUST ALSO EXTEND A 2.6.4 PV SYSTEM CIRCUITS INSTALLED ON OR IN BUILDINGS SHALL INCLUDE A MINIMUM DISTANCE BEYOND EITHER EDGE OF THE ARRAYISUBARRAY, RAPID SHUTDOWN FUNCTION TO REDUCE SHOCK HAZARD FOR EMERGENCY 168 CRESCENT ST ACCORDING TO RAI MANUFACTURER'S INSTRUCTIONS. RESPONDERS IN ACCORDANCE WITH 690.12(A)THROUGH(D). NORTHAMPTON,MA 01060 233 JUNCTION BOX WILL BE INSTALLED PER MANUFACTURERS'SPECIFICATIONS. 2.6.5 ALL OCPD RATINGS AND TYPES SPECIFIED ACCORDING TO NEC 690.8,690 9, APN: IF ROOF-PENETRATING TYPE,IT SHALL BE FLASHED 8 SEALED PER LOCAL AND 240. NHAMM:024DB:0288L:0001 4 REQUIREMENTS. 2.6.6 MICROINVERTER BRANCHES CONNECTED TO A SINGLE BREAKER OR 2.3.4 ROOFTOP PENETRATIONS FOR PV RACEWAY WILL BE COMPLETED AND GROUPED FUSES IN ACCORDANCE WITH NEC 110.3(8). SEALED W7 APPROVED CHEMICAL SEALANT PER CODE BY A LICENSED 2.6.7 If REQUIRED BY AHJ,SYSTEM WILL INCLUDE ARC-FAULT CIRCUIT PROTECTION ENGINEER OF RECORD CONTRACTOR. ACCORDING TO NEC 690.11 AND UL1699B 2.3.5 ALL PV RELATED ROOF ATTACHMENTS TO BE SPACED NO GREATER THAN THE SPAN DISTANCE SPECIFIED BY THE RACKING MANUFACTURER. 2.7.1 INTERCONNECTION NOTES: 236 WHEN POSSIBLE, ALL PV RELATED RACKING ATTACHMENTS WLL BE 2.7.2 LOAD-SIDE INTERCONNECTION SHALL BE IN ACCORDANCE WITH[NEC 705.12 STAGGERED AMONGST THE ROOF FRAMING MEMBERS. (B)] 2.7.3 THE SUM OF THE UTILITY OCPD AND INVERTER CONTINUOUS OUTPUT MAY 2 4.1 HARING 8 CONDUIT NOTES: NOT EXCEED 120%OF BUSBAR RATING[NEC 705.12(0)(2)(3)]. 242 ALL CONDUIT AND WIRE WILL BE LISTED AND APPROVED FOR THEIR PURPOSE. 2.7.4 THE SUM OF 125 PERCENT OF THE POWER SOURCE(S)OUTPUT CIRCUIT CONDUIT AND WIRE SPECIFICATIONS ARE BASED ON MINIMUM CODE CURRENT AND THE RATING OF THE OVERCURRENT DEVICE PROTECTING THE REQUIREMENTS AND ARE NOT MEANT TO LIMIT UP-SIZING BUSBAR SHALL NOT EXCEED 120 PERCENT OF THE AMPACITY OF THE S 2 4.3 CONDUCTORS SIZED ACCORDING TO NEC 690.8,NEC 690.7. BUSBAR,PV DEDICATED BACKFEED BREAKERS MUST BE LOCATED OPPOSITE PAPER SO n•.+rywsl N 244 VOLTAGE DROP LIMITED TO 1.5%. END OF THE BUS FROM THE UTILITY SOURCE DCPD[NEC 705.12(B)(2)(3)]. NOTES 245 DC WIRING LIMITED TO MODULE FOOTPRINT. MICROINVERTER WIRING 2.7.5 AT MULTIPLE ELECTRIC POWER SOURCES OUTPUT COMBINER PANEL,TOTAL SYSTEMS SHALL BE LOCATED AND SECURED UNDER THE ARRAY W7 SUITABLE RATING OF ALL OVERCURRENT DEVICES SHALL NOT EXCEED AMPACITY OF WIRING CLIPS. BUSBAR. HOWEVER, THE COMBINED OVERCURRENT DEVICE MAY BE DATE: 7.12.2019 246 AC CONDUCTORS COLORED OR MARKED AS FOLLOWS EXCLUDED ACCORDING TO NEC 705.12(B)(2)(3)(C). DESIGN BY:MC. PHASE A OR Li-BLACK 2.7.6 FEEDER TAP INTERCONECTION (LOAD SIDE) ACCORDING TO NEC 705.12 PHASE B OR 1_2-RED,OR OTHER CONVENTION IF THREE PHASE (BX2)(1) CHECKED BY: MM. PHASE C OR L3-BLUE,YELLOW,ORANGE",OR OTHER CONVENTION 2.7.7 SUPPLY SIDE TAP INTERCONNECTION ACCORDING TO NEC 705.12(A)WITH NEUTRAL-WHITE OR GREY SERVICE ENTRANCE CONDUCTORS IN ACCORDANCE WITH NEC 230.42 REVISIONS 6 IN 4-WIRE DELTA CONNECTED SYSTEMS THE PHASE WITH HIGHER VOLTAGE 2.7.8 BACKFEEDING BREAKER FOR ELECTRIC POWER SOURCES OUTPUT IS EXEMPT TO BE MARKED ORANGE[NEC 110.151. FROM ADDITIONAL FASTENING[NEC 705.12(B)(5)1. G-001.00 A B m C D E F G H (SHEF T>, a B C D E F G H GENERAL NOTES FIELD VERIFY ALL MEASUREMENTS CI D EM N / 2. ITEMS BELOWMAYNOTBEON THIS PAGE / ------- PROPERTYLINE CONTRACTOR DEVLIN CONTRACTING AND Ntst MAINTENANCE,INC C� - PHONE: 781-812-0240 ADDRESS:86 FINNELL DR 021 WEYMOUTH,MA 02188 LIC.NO.: INC.NO.: i ELE.NO.: UNAUT/\ DRAWNGRVED SETICSEGFTws \\ \ PERMING SN FROM CON TRACTOR / PERMISSION FROM CONTRACTOR IS IN \ \ WS MOWILLSUBJECT OCMLPYR HT u DAMAGES AND PROSECUTIONS ENTRANCE 27'-0" \ NEW PV SYSTEM:4.225 kWp SHOTLAND RESIDENCE 168 CRESCENT ST NORTHAMPTON,MA 01060 \� APN: 4 ��` NHAMM:024DB:0288L:0001 AC LOAD CENTER ��` • ENGINEER OF RECORD MM SMARTGEIAC DISCONNECT IS N METER AC \ \ pSCONNECT � UTIUTYMETER 8'-8" �• AREA OFWORK � \ 38'-0" S PAPER SIZE TI'x TT PNSIw SITE PLAN DATE: 7.12.2018 DESIGN BY:MC CHECKEDBY: M.M. SITE PLAN " 6 REVISIONS 1116'z1116°=1'-0" 0® w S E A-101.00 B C D E F G h (SHEET 3) A B C D E F G H GENERAL NOTES 1 FELDVERIFY ALL A&SUREAENTS Jr, DEVLIN 2. ITERS BELOW MAY NOT BE ON THIS PAGE iPxr,nc:M.vNT�w,cF A MODULE STRINGING CONTRACTOR DEVLIN CONTRACTING AND ARRAY 2-0.975 kW MAINTENANCE,INC (x3l(M MODULES TILT 34 DEGREES ROOF PITCH:8:12 AZIMUTH 61 DEGREES PHONE: 781-812-0240 ADDRESS:86 FINNELL DR N21 IEWEYMOUTH,AAA 02188 LIC.NO.: HIC.NO.: ELE.NO.: INTERIOR PV EQUIPMENT uNauTHOH¢Eo USE of 1HIs (E)(1)MAIN ELECTRICAL PANEL NRAWNG SET YATNOUT WRITTEN PERMISSION FROM CONTRACTOR IS IN MOIATION OFU 5 COPYRIGHT TAWS 3 �A O AI4IMMSANOP OSECU GNI CAIVxiESAND BJECT OTpM NEW PV SYSTEM:4.225 kWp SHOTLAND O O RESIDENCE (N)(1)JUNCTION BOX 168 CRESCENT ST ( 1 I A l O A `/ NORTHAMPTON,MA 01060 o ARRAY 1-3 250 kW APN: (x101('1)MODULES a o TILT 34 DEGREES NHAMM:024DB:0288L:0001 ROOF PITCH-812 AZIMUTH 241 DEGREES ENGINEER OF RECORD EXTERIOR PV EQUIPMENT (E)(1)UTILITY METER lM(1)AC DISCONNECT 0)MA SMART GENERATION METER 94(1)AC LOAD CENTER S PAPER9REw iTIANSi9) ELECTRICAL PLAN 39.4" DATE: 7.12.2019 DESIGN BY:1AC. MODULE: CHECKED BY. M.M. F h HANWHA s REVSIONSELECTRICAL PLAN 63" QPEAK DUO-G5 325 o 325 WATTS 1— A-102,00 A B C D E F G H (sr4eT4) 1 A B C D E F G H GENERAL NOTES `' 1 1. FIEVERIFY ALL NFASIIREAIFNTS ,t D E�/L IN 2 ITEMS BELOW MAY NOT BE ON THIS PAGE ROOF RAFTERS CONTRACTOR DEVLIN CONTRACTING AND 2 1 fi�-7° MAINTENANCE,INC PHONE: 781-812-0240 r I T I 1 1 1 1 1 I ADDRESS:86 PNNELL DR 41 LIC.NO.: WEYMOUTH,MA 02188 I 1 1 I 1 1 I I I T I I 1 I 1 1 I 1 I I I I 1 1 1 I I 1 I I r I 1 I I I HIC.NO.: I I I I I I I I I I I I I I I I ELE.NO.: 1 1 I I I I 1 I I I I I I I I I 1 UNAUTHORIZED USE OF THIS 1 _.♦_;_.. _ _.-1_j... 1 I 1 I 1 I 1 DRAVVNG SET WTHOUT MITTEN 1 I 1 PERMISSION FROM CONTRACTOR IS IN I I 1 I I 1 1 1 VIOLATION Of US COPYRIGHT LAWS I 1 I I I I I I I 1 1 I 1 1 I I AN)M BESUBJECTTOCI 3 VIL I 1 I I I I I I I I I I I I DAIMOES AND PROSECUTIONS I 1 I 1 1 I I I I 1 I I I I NEW PV SYSTEM:4.225 kWp t.-A— 1 1 SHOTLAND FLUSN MOUNT SOUR MIRESIDENCE 1 T 4 -t' 1- I-_.t I i I 'I - I ..TA3HED TO ROOF SIRFASE."i_[-- +--a— —1--a-. 1— a- 1- ♦. -I- a, 1 SHEET S$DI FOR MOUNTING I".+FS: 168 CRESCENT ST I 1 I0 I I 1 I I 1 I I I I 1 I 1 —�— ROOF AISTER4.L IS 2 LAYER :T 1NR+GLE 1 I 1 1 1 1 1 4,111, NORTHAMPTON,MA 01060 APN: 4NHAMM:024DB:0288L:0001 27'-9" _ ENGINEER OF RECORD Richard B.Gordon,P.E. MA.P E Llc.At 49993 IF E.Llc.Exp.date 06-30-2020 Civil,Mechanical,8:Electrical +TMbc " Engineering ELECTRICAL NGINEERINC y 0 q xP CML AThle EN INEERING 5 PAPER SIZE 11'11T(ANSI B) July 29,2019 SOLAR ATTACHMENT PLAN 39 4' DATE: 712.2019 j'"� OFSIGN BY:MC T MODULE. CHECKEDBY: MM. 6 7 SOLAR ATTACHMENT PLAN 5 S' Q.PEAK UO-G53Q-CELLS RESIGNS 01 Q.PEAK DUO-G5 325 178•=P o 6 1- 325 WATTS A"103.00 A B C D E F G H (SHEET 5) A B C D E F G H CONDUCTOR AND CONDUIT SCHEDULE W/ELECTRICAL CALCULATIONS CURRENT CARRYING CONDUCTORS ID TYPICAL CONDUCTOR CONDUIT OCPD EGC TEMP.CORR.FACTOR CONDUIT FILL FACTOR CONT CURRENT MAX CURRENT(125%) BASE AMP CRATED AMP. TERM TEMP RATING AMP 0 TERMINAL IN CONDUIT D EVLI N 1 01 1 10 AWG THWN 2,COPPER 0.5°DIA EMT 2 20A B AWG THWN 2.COPPER 0 76(54.7•C) 1 13A 1625A 40A Ei 75'C 35A wrl 1 10 AWG THWN-2,COPPER 05"DIA EMT 2 NIA 8AWG THWN-2,COPPER 096(32.7•C) 1 13A 1625A 40A i8 ea 75'C 35A 3 10 A'NG THWN-2,COFPCR 'v1A cdT NIA 8i:VG TV.VN-2,COP"C: 096(327'C) i3A iE eSA 4CA 78.4 35A 1 10 AWG THWN 2,COPPER 05'DIA EMT 2 20A 8AWG THWN-2.COPPER 0.96(32 7'C) 1 13A 16.25A 40A 38 nA 751C 35A A MODULE STRINGING CONTRACTOR DE W N CONTRACTING AND 2 MAINTENANCE,INC MAIN SERVICE PANEL 60A LOAD CENTER TO UTILITY 240/120 V 10,3W PHONE: 781-812-0240 120/240V,10,3W GRID(OH) MAIN BUSS:100A ADDRESS:86 FINNELL DR#21 MAX.CONTINUOUS CURRENT:48A n n A MAX BREAKER SIZE: WEYMOUTH,MA 02188 MAX.OCPD:60A (100A x 1.2)-100A=20A LIC.NO.: HIC.NO.: LL1 ELE.NO.: UNAUTHORIZED USE 9 THIS ENPHASE ENVOY N DRAWNG SET WITHOUT MITTEN PERMISSION FROM CONTRACTOR IS IN 1. PV SYSTEM EQUIPEED WITH COMMUNICATIONS L2 ANOµ1TLON OF UB EONCI F HT uWS 3 RAPID SHUTDOWN GATEWAY DAMAOESANDPROSEOUTIONS 2. SYSTEM COMPLIANT WITH NEW PV SYSTEM:4.225 kWp NEC 690.12. IE)120V OUTLET , (E) SH®TLAND UTILITY METER RESIDENCE 5A GROUND 168 CRESCENT ST MA SMART AC DISCONNECT ROD NORTHAMPTON,MA 01060 ® GENERATION 30A APN: 4 METER NHAMM:024DB:0288L 0001 N G (E)GROUNDING ENGINEER OF RECORD ELECTRODE ENPHASE (E)MAIN IQ7-60-2-US TOP LUGS 100A A - 01 C=1 13 I. 0 20A 02 osL I oa N 20�2P GADS IN BRANCH RED L2 5 L1 PAPER 512E tI'.tT(AN518) LINE DIAGRAM HANWHA Q-CELLS JUNCTION BOX LOAD -' LINE Q.PEAK DUO-G5 325 EQUIPMENT LEFT EQUIPMENT RIGHT DATE: 2291s 325W LINE IS(N)NEW LINE IS(E)EXISTING DESIGN BY MC BOTTOM LUGS UNLESS OTHERWISE NOTED CHECKED BY: M.M. 6 REVISIONS E-601.00 A B C D E fm G H (SHEET 6) A B C D E F G H DEVLIN SYSTEM SUMMARY MODULES BRANCH M1 F. QTY. MAKE AND MODEL PMAX PTC ISC IMP VOC VMP TEMP.COEFF.OF VOC FUSE RATING INVERTERS PER BRANCH 13 PI41-13 13 HANWHA G CELLS O.PEAK DUO.05325 325W 300.7W 10.14A 9.661 40.4V 33.65V -0.113V/'C(-0 28'k/-C) 20A MAX AC CURRENT 13A MAX AC OUTPUT POWER 3,25OW INVERTERS CONTRACTOR ARRAY STC POWER 4,225W OCPD MAX OUTPUT MAX INPUT CEC WE ARRAY PTC POWER 3,909W F. TY MAKE AND MODEL VOL GROUND RATING RATED POWER CURRENT CURRENT INPUTVOLT EFFICIENCY DEVLIN CONTRACTING AND 2 MAXACCURRENT 13A �1-11 13 ENPHASE 10740-2-US 240V FLOATING 20A I 24OW I ,A ISA 48V 97.0% MAINTENANCE,INC ---R 3,250W DERATED(CEC)AC POWER 3.25OW DISCONNECTS OCPDS REF.QTY. MAKE AND MODEL RATED CURRENT I MAX RATED VOLTAGE 1 REF. QTY. RATED CURRENT MAX VOLTAGE PHONE: 781-012.0240 DESIGN TEMPERATURES SWI I EATON OG221URB OR EQUIV. 30A 240VAC CB1.t 2 20A 240VAC ADDRESS:86FBYELLDR121 ASHRAE EXTREME LOW .25.9'C(.14.6'F),SOURCE.BARNES MUNI(42.1x,-72.727 CO2 1 5A 240VAC WEYMDUTH,MA 02188 ASHRAE 2%MC�i 32.7'C(9).9'F),SOURCE BARNES MUM(42.16';.72.72') LIC.NO.: HIC.NO.: ELE.NO.: UNAUTHORIZED USE OF THIS DRAMNG SET WTHOUT WTTEN PERMISSON BILL OF MATERIALS NW PON OF U S COWn""GGT TAMS CATEGORY MAKE MODELNUMBER REF OTY UNIT OTYAJMT DESCRIPTION MA ESANDROSE UnONS 3 MODULE HANWHACHCELLS O.PEAK DUO-G5325 PMI.13 t3 PIECES 1 HANWHAO-CELLSO.PEAK DUO-G5325325WI20 HALF-CUT CELLS,MONOCRYSTALLINE SILICON uAA1ACESA+o vnosecuno"s INVERTER ENPHASE 10740-2-US I1-13 13 PIECES I ENPHASE 10740.2-US 240W INVERTER NEW PV SYSTEM:4.225 kWp DISCONNECT EATON DG221URB SW7 I PIECE 1 EATON DG221URB,2-POLE,30A,240VAC OR EQUIVALENT PRODUCTION METER GENERIC MANUFACTURER GEN-METER-BOA M1 1 PIECE I MA SMART GENERATION METER SHOTLAND MISC ELECTRICAL EQUIPMENT GEN-CABLE-CLIP HDWR16-81 65 PIECES i GENERIC CABLE CLIP AC COMBINER PANEL ENPRASE-IQ-PANEL Epi 1 PIECE 1 ENPHASE IQ COMBINER(X.10-AMI-240-8) MONITORING ENPHASE-ENVOY ENVI I PIECE 1 ENPHASEENVOY RESIDENCE WIRING ENPHASE 0.12-17-240 ENI-13 13 PIECES 1 ENPiASE ENGAGE(TM)TRUNK CABLE FOR 60 CELLS MODULE LANDSCAPE LAYOUT WIRING ENPHASE UTERM-10 EN14 1 B UNDLE ENPHASE ENGAGE(TM)BRANCH TERMINATOR WIRING ENPHASE 65EAL-10 ENIS 1 ENPHASE ENGAGE(TM)WATERTIGHT SEALING CAP 168 CRESCENT ST WRING GEN-1O -THAN-2-CURD WR14 9010AWGTHNM-2,COPPERRED(LINE1) NORTHAMPTON,MA 01060 WRING GEN-10.AWCTHWN-2-CU-BLK WR14 9D10 AWGTHWN-2,COPPER BLACK(LINE2) APN: WRING GEN-10AWS-THINN-&CU-WH WR2-1 50 10 AWG THWN-2,COPPER WHITE(NEUTRAL) 4 WRING GENA-AWG-THWN-2CU-GR WR14 908AMTHWN-2,COPPER,GREEN(GROUND) NHAMM:024DB:0288L:0001 WREWAY ENPHASE ET SPLX-05 EN16 1 ENPHASE ENGAGE QM)ENGAGE COURER WREWAY GEN EMT-0_SDIA WW14 90EMrc.N.""..5•DIA ENGINEER OF RECORD CCPD GENERIC MANUFACTURER CEWCB-20A-240VAC 081,3 2 PIECES 1 1 CIRCUIT BREAKER,20A,240VAC OCPD GENERIC MANUFACTURER GEN-CB-SA-240VAC C82 1 PIECE 1 CIRCUIT BREAKER,5A,240VAG TRANSITION BOX GENERIC MANUFACTURER GEN-JB JB1 1 PIECE 1 JUNCTION BOX 5 PAPER SIZE Ii'.Ir(ANSI BI DESIGN TABLES DATE: 7.121019 DESIGN BY:MC. CHECKED BY: MM. REVISIONS 6 E-602.00 A B C D E F G H A B C D E F G H ° !CAUTION! ° ir�DEVLiN POWER TO THIS BUILDING IS ALSO SUPPLIED FROM ROOF MOUNTED SOLAR ARRAYS WITH SAFETY DISCONNECTS AS SHOWN: CONTRACTOR DEVLIN CONTRACTING AND 2 PV ARRAY MAINTENANCE.INC • • m MAIN DISTRIBUTION PHONE: 781812 0240 RAPIDWITH D UTILITY DISCONNECT ADDRESS:86 FINNELL DR 021 WEYMOUTH,AIA 02188 TURN RAPID SHUTDOWN FRONT BACK LIC.NO.: LABEL 3 SWCH TO THE'OFF HIC.NO.: AT EACH DISCONNECTING MEANS FOR POSITION TO SHUTDOWN PVARRAY ELE,NO.: PHOTOVOLTAIC EQUIPMENT PV SYSTEM AND EDUCE JNAUT ORIZED USE OF THS [NEC 69013 AND 690151 SHOCK HAZARD IN ARRAY DRAMING SET AITHOUT MITTEN PERMISSION FROM CONTRACTOR IS N 7 MOIATg OF U 5 COPIPoGHT LAMS 4' AND"L BE SUBJECT TO CIVIL 3 LABEL LABEL PV DISCONNECT CAMAGES AND PROSECUTIONS AT RAPID SHUTDOWN SYSTEV AT RAPID SHUTDOWN SYSTEM [NEC 690 56(C)I1)(A)J [NEC 690%(C)(1)(B)1. DIRECTORY NEW PV SYSTEM:4.225 kWp _M 6 _._ PERMANENT PLAQUE ORDIRY ICAIITit?i''i INTERACTIVE PHOTOVOLTAIC SYSTEM THELOCATIONCTORY OF a O SHOTLAND O CONNECTED C1 SERVICCATION OF THE PHOTOVOLTAIC SYSTEM DISCONNECT LOCATED DISCONNECTING MEANS RESIDENCE SW SIDE OF THE HOUSE AND THE PHOTOVOLTAIC LABEL 6 LABEL 7 PLAQUE SYSTEM DISCONNECTING 168 CRESCENT ST MEANS IF NOT IN THE AT POINT OF INTERCONNECTION,LABEL.SUCH AS LABEL 5 OR LABEL 6 MUST IDENTIFY SAME LOCATION NORTHAMPTON,MA 01060 PHOTOVOLTAIC SYSTEM (NEC 690.56(8)1 APN: [NEC 70512(B)(4)) WHERE THE PV SYSTEMS 4 PHOTOVOLTAIC ARE REMOTELY LOCATED NHAMM:024DB:0288L:0001 SYSTEMEACH 0 INTERACTIVE PHOTOVOLTAIC SYSTEM o a AC DISCONNECT o PHOTOVOLTAIC EQUIPPED WITH RAPID DIR EOM CTORY NTHER A ENGINEER OF RECORD CONNECTED ACCORDANCE WITH 70510 OPERA NG CURRENT 13A Ac SHUTDOWN SHALL BE PROVIDED AT OPERATNGVOLTAGE 240VAC EACH PV SYSTEM LABELS F ABEL 5 LABEL 10 DISCONNECTING MEANS AT UTILITY METER AT POINT OF INTERCONNECTION,MARKED AT RAPID SHUTDOWN SNITCH PV SYSTEM EQUIPMENT [NEC 690 56(8)1 AT DISCONNECTING MEANS [NEC 69056(C)J AND DISCONNECTING [NEC 690.541 LETTERS AT LEAST 3/8 INCH,WHITE ON RED MEANS SHALL NOT BE BACKGROUND,REFLECTIVE INSTALLED IN BATHROOMS FC 606 111.1 [NEC 690 4(D),(E)1 WARNING PHOTOVOLTAIC o PHOTOVOLTAIC a FMPERS0 71A"B) POWER SOURCE__ AC DISCONNECT PLACARDS LABEL 11 LABEL 12 LABEL 13 AT EXPOSED RACEWAYS,CABLE TRAYS,AND OTHER HARING AT EACH AC DISCONNECTING MEANS AT POINT OF INTERCONNECTION DATE: 712.2019 METHODS,SPACED AT MAXIMUM 10 FT SECTION OR WHERE [NEC 69013(B)1 OVERCURRENT DEVICE DESIGN BY:MC. SEPARATED BY ENCLOSURES,WALLS,PARTITIONS,CEILINGS, LABELING NOTES [NEC 705 12(B)(2)(3)(B)J OR FLOORS 1 1 LABELING REQUIREMENTS BASED ON THE 2017 NATIONAL ELECTRICAL CODE,INTERNATIONAL FIRE CODE 60511,OSHA CHECKED BY: MM. [NEC 690 31(G)1 STANDARD 1910145,ANSI Z535 LETTERS AT LEAST 378 INCH,WHITE ON RED BACKGROUND. 12 MATERIAL BASED ON THE REQUIREMENTS OF THE AUTHORITY HAVING JURISDICTION REVISIONS 6 REFLECTIVE 13 LABELS TO BE OF SUFFICIENT DURABILITY TO WITHSTAND THE ENVIRONMENT INVOLVED [IFC 605 11 1 11 14 LABELS TO BE A MINIMUM LETTER HEIGHT OF 378'AND PERMANENTLY AFFIXED 15 ALERTING WORDS TO BE COLOR CODED 'DANGER'WILL HAVE RED BACKGROUND'WARNING*WILL HAVE ORANGE E•603.00 BACKGROUND,'CAUTION'HALL HAVE YELLOW BACKGROUND[ANSI Z5351 A B C m0 E F G ir H (SHEETB) T H - B — C _E'----- E G a H D4 ® GENERAL NOTES rD5N S,�t .. EVUN 4 5 e 3T _ 1. EELDVERIFY ALL MEASUREMENTS 3 24 25 tjj 0 15 18 22 12 CONTRACTOR 3 b b DEVLIN CONTRACTING AND 2 MAINTENANCE.INC � RACKING DETAIL (LONGITUDINAL)D2 0 SHEET KEYNOTES RHONE: 181-812-0240 NOT TO SCALE ADDRESS: L DR A921 1 ROC4'MATERIAL ASPHALT SHINGLE WEYMOUTH, EYMOUYMOU MA02t168 02188 ' 2 ROOF STRUCTURE COLLAR TIE �PL 3. ,4i TACKMENT TYPE UNIRAC FLAT FLASHING LIC.NO.: 4 NCCULE MANUFACTURER HANMMA 0-CELLS HIC.NO.: H RACKING DETAIL TRANSVERSE 5 MY ILETPEAK DUO-G5325 ELI.NO.: 6 NOLl1LE LENGTH 6831N uuurHomzeoUSE arws LD1 Sister rafters with a 2x6 full length end bearing to end beam using Paslode 650649 or Paslode 650647 7 NCCULE WDTH 39 41N DRAWNG SET HOUTMITTEN 9 9 9 9 PERMISSION FROM CONTRACTOR IS IN NOT TO SCALE 8. SEE SHE WEIGHT 412 LBS NCMArON OF US COPYRIGHT uws (2)10d nails 1'o.c. Use also adhesive such as Loctite PL or Liquid Nails LN907 or LN903 low VOC, B. SEE SHEETA-103 FOR DIMENSION(S) ANoxxL a sus,•Ecr rotML 3 between the rafter and the member used to sister. Sister required only at those rafters that have rail 10 MN FIRE OFFSET NO FIRE CODE ENFORCED DIVAGESANOPROSECUDONS o Q anchorN 12 FTER SIZE.2X6 NOMINAL s mounted into them 11 FTER SPACING 0 C NEW PV SYSTEM:4.225 kWp 13 LIG BUT DIAMETER:5M61N 14 UR+SOLT EMBEDMENT 2-112 IN 15 TOTAL#OF ATTACHMENTS 42 SHOTLAND 10 I 16. TOTAL AREA 235.83 SO FT ' 17 TOTAL V.EIGHT 67CHMEN LEIS RESIDENCE 18 MICa1TPERATTACHMENT 1598 L&S 19. D15TFIBUTED LOAD 2 85 PSF 20 W..X HORIZONTAL STANDOFF 48 IN 168 CRESCENT ST 21 BMX VERTICAL STANDOFF O O LANDSCAPE 311N..PORTRAIT.501N NORTHAMPTON,MA 01060 22 SIANOOFF STAGGERING YES APN: 23RAIL MANUFACTURER(OR EOUIV.).UNIRAC 4 z4 PAILMODEL(OREQUIVALENT)STANDARD NHAMM:024DB:0288L:0001 25 RRL*E,3HT,0728PLF 26 MAX RAFTER SPAN 160 IN ENGINEER OF RECORD 27 MODULE CLEARANCE:31N,MIN,6 I MAX Richard B Gordon.P.E. O MA.P E.LIc.#49993 RACKING DETAIL (TOP) PE Lic.Exp date: 06-3trical �� Civil,Mechanical,&Electrical Engineering D3 NOT TOSCALE t ``'�u ELECTRICAL NGINEERING y� 4 CML 5 h t 7 ENGINEERING PAPER9RE 1,'oT(NISIBI ASSEMBLY DETAILS July 29,2019 DATE: 7.12.2019 DESIGN BY:MC CHECKED BY: MM 1 6I DETAIL (TRANSVERSE) DETAIL LONGITUDINAL) REVISIONS � NOT i0 SCALE D5 NOT TO SCALE S-501.00 �---A - ■�- -----B---- C r--.p--�----E---- ----- F - T_----- _.---� - H SHeersl