Loading...
10160 - 2901Not For Construction 10160 - 1 2901 - Northampton, Massachusetts - 1452013 April 21, 2015 UniSpec II- Store Planning 102513 SECTION 10160 - METAL TOILET COMPARTMENTS PART 1 - GENERAL 1.1 SUMMARY A. Work Includes: 1. Stainless steel toilet compartments and screens, floor mounted, head rail braced, Owner furnished, Contrac- tor installed. B. Related Sections: 1. Section 01640 - Owner Furnished Products: General procedures related to Owner furnished products. 2. Section 06100 - Rough Carpentry: Framing and plates within walls. 3. Section 10810 - Toilet Accessories: Coordinate compartment installation with subsequent accessory instal- lation. 1.2 REFERENCES A. American National Standards Institute (ANSI): ANSI A117.1 - Specification for Making Buildings and Facilities Accessible To and Usable by Physically Handicapped People. B. Americans with Disabilities Act (ADA), ADA-ADAAGS - 2010 ADA Standards for Accessible Design. C. State and local disabled accessibility requirements and guidelines. 1.3 DELIVERY, STORAGE AND HANDLING A. Transport, handle, store, and protect products in compliance with the requirements of Section 01600. B. Receive Owner Furnished products in accordance with the requirements of Section 01640. C. Product Delivery: Owner’s Supplier will deliver products to site to be received by Contractor. Contact Owner’s Supplier to coordinate product delivery and installation. D. Acceptance at Site: Inspect products upon delivery to Site to verify quantity, and report discrepancies in quantity delivered or damage. E. Product Packaging: Products will be delivered in manufacturer's original packaging with identification markings on each component or package. PART 2 - PRODUCTS 2.1 OWNER FURNISHED PRODUCTS A. Owner’s Supplier will furnish products as specified herein under provisions of Section 01640 for installation by Contractor. 1. Owner’s Supplier: Haines, Jones & Cadbury, Inc., Contact: Customer Service, (800) 459-7099, fax (479) 756-8998, Email: WMT@hjcinc.com. B. Descriptions and related provisions of products by Owner’s Supplier as specified herein are included as require- ments for Supplier of products to be furnished by Owner and are included as information only to Contractor. 2.2 MANUFACTURERS Not For Construction 10160 - 2 2901 - Northampton, Massachusetts - 1452013 April 21, 2015 A. Subject to compliance with project requirements, provide stainless steel toilet compartments and screens, as manufactured by the following: 1. Mills Partitions (A Subsidiary of Bradley) 2. Accurate Partitions Corp. 3. Flush Metal Partition Corp. 4. Global Steel Products, Deer Park, NY. B. Products of named manufacturers shall strictly comply with all material and fabrication provisions specified below. 2.3 METAL TOILET PARTITIONS (OWNER FURNISHED, CONTRACTOR INSTALLED) A. Stainless Steel Compartments and Screens: Provide the following: 1. Model: a. Sentinel Overhead Braced – Series 400 by Mills. b. Stainless Steel by Accurate Partitions. c. Stainless Steel by Flush Metal. d. Stainless Steel by Global Steel Products. 2. Panels: Form panels as two-piece interlocking unit with corners brazed and finished smooth. Panel face shall be stainless steel 304, insulated honeycomb core adhered to inner surfaces with moisture resistant ad- hesive. a. Side Panels and Doors: 22 gauge sheet steel, 1 inch thick composite panel. b. Pilasters: Min 22 gauge sheet steel, 1-1/4 inch thick composite panel. 3. Finish: Textured "diamond" pattern similar to Rigidized 5WL. Pattern in panels shall be without seams. B. Urinal Screens: Wall hung type, 24" x 48" to match toilet compartments. C. Pilaster Shoes: 3 inches high; one-piece stainless steel. D. Headrail: Extruded clear anodized type 6463T5 aluminum channel; anti-grip design. E. Wall and Side Panel Mounting Brackets: 18 gauge stainless steel #4 finish. Brackets shall be one piece continuous roll-formed shape, pre-punched and free of sharp edges. Resistance and/or spot welded brackets will not be acceptable. F. Join panel and pilaster with full length continuous stainless steel bracket to eliminate sight between stalls. G. Hardware: 1. Hinge: Cast stainless steel, wrap-around and through-bolted. 2. Latch: Cast stainless steel service mounted slide latch, thru-bolted. Strike keeper shall be wrap-around type, thru-bolted. 3. Coat Hook and Wall Bumper: Cast stainless steel with rubber bumper. 4. Pull Handle: Cast stainless steel, through-bolted to door. H. Screws/Fasteners: Tamper proof, stainless steel, 6-Lobe/Pin sex bolts. PART 3 - EXECUTION 3.1 PREPARATION A. Take site dimensions prior to fabrication of any items. Verify correct spacing of plumbing fixtures. B. Verify correct location of built-in framing, anchorage, and bracing. 3.2 INSTALLATION Not For Construction 10160 - 3 2901 - Northampton, Massachusetts - 1452013 April 21, 2015 A. Install partitions secure, rigid, plumb, level, and square. Secure units in position with manufacturer’s anchoring devices and in accordance with manufacturer’s instructions. 1. Provide for adjustment due to minor floor variations. 2. Install adjacent components for consistency of line and plane. B. Maintain 1/2 inch space between wall and panels, and between wall and pilasters. C. Attach panels and pilasters to bracket with through sleeve, tamperproof bolts, and nuts. Locate head rail joints at pilaster centerlines. D. Anchor urinal screen panels to walls with brackets in accordance with manufacturer's instructions to suit supporting wall construction. E. Attach panel brackets securely to walls using anchor devices. F. Conceal floor fastenings with pilaster shoes. G. Equip each door with hinges, one door latch and one coat hook and bumper. Align hardware to uniform clearance at vertical edges of doors, not exceeding 1/4 inch. H. Install pull handles on both sides of toilet partition doors for handicapped and ambulatory stalls. 3.3 ADJUSTING A. In Swinging Doors: Adjust hinges to hold doors in partially open position when unlatched. B. Out Swinging Doors: Adjust hinges to gently return doors to closed position. 3.4 CLEANING A. Protection and Cleaning of Stainless Steel Toilet Compartments and Screens Prior to Possession 1. Remove protective plastic coating from stainless steel partitions. Remove any residue from the plastic coating with mild soap and water. 2. Caution: Muriatic acid or other caustic chemicals shall not be used to clean stainless steel products. Muri- atic acid for cleaning masonry or similar hydrochloric acid type cleaners must immediately be neutralized and scrubbed off with clean water if splashed, sprayed, spilled or otherwise in contact with a stainless steel component. 3. Immediately prior to possession, clean stainless steel toilet compartments and screens thoroughly using soap, ammonia, or mild detergent and water. Apply with sponge or soft cloth, rinse with clear water and wipe dry. Always rub in the direction of polish lines. Rinse thoroughly with fresh water after every clean- ing operation. Clean and polish toilet partitions to a spotless luster. Wipe dry to avoid water marks. END OF SECTION Not For Construction 10160 - 4 2901 - Northampton, Massachusetts - 1452013 April 21, 2015