41 -069 CS 2nd floor girder CalcsCS Structure™ 2016.11 [Build 16] kmBeamEngine 2016.9.0.3 Materials Database 1557 AudetteLarryCooke - Level 8 6- 2-17 9:18am 1 of 8 All product names are trademarks of their respective owners Copyright (C) 2016 by Simpson Strong-Tie Company Inc. ALL RIGHTS RESERVED.**Passing is defined as when the member, floor joist, beam or girder, shown on this drawing meets applicable design criteria for Loads, Loading Conditions, and Spans listed on this sheet. The design must be reviewed by a qualified designer or design professional as required for approval. This design assumes product installation according to the manufacturer`s specifications. Doug Hodgins rk Miles Inc. 21 West St. West Hatfield Ma. Member Data Description: CalcG10 Member Type: Girder Application: Roof Comments:Top Lateral Bracing: Continuous Slope: 0.00 / 12 Bottom Lateral Bracing: Continuous Standard Load: Moisture Condition: Dry Building Code: IBC/IRC Live Load: 0 PLF Deflection Criteria: L/360 live, L/240 total Dead Load: 0 PLF Deck Connection: Nailed Member Weight: 28.4 PLF Filename: C:\KMW\JOBS\ Other Loads Type (Description) Side Begin End Trib. Width Other Start End Dead Start End Category Replacement Uniform (PLF) Top 0' 0.00" 2' 3.00" 58 271 Live Replacement Uniform (PLF) Top 0' 0.00" 2' 3.00" 458 0 Snow Replacement Uniform (PLF) Top 2' 3.00" 11' 8.50" 58 332 Live Replacement Uniform (PLF) Top 2' 3.00" 11' 8.50" 607 0 Snow Replacement Uniform (PLF) Top 11' 8.50" 15' 5.50" 58 332 Live Replacement Uniform (PLF) Top 11' 8.50" 15' 5.50" 607 0 Snow Replacement Uniform (PLF) Top 15' 5.50" 17' 9.50" 58 332 Live Replacement Uniform (PLF) Top 15' 5.50" 17' 9.50" 607 0 Snow Point (LBS) Top 17' 4.88" 1 95 Live Point (LBS) Top 17' 4.88" 270 0 Snow 1 2 17 9 8 17 9 8 Bearings and Reactions Input Min Gravity Gravity Location Type Material Length Required Reaction Uplift 1 0' 0.000" Wall SPF Plate (425psi) N/A 2.664" 7924# -- 2 17' 9.500" Wall SPF Plate (425psi) N/A 2.914" 8670# -- Maximum Load Case Reactions Used for applying point loads (or line loads) to carrying members Live Snow Dead 1 499# 4939# 2985# 2 501# 5480# 3190# Design spans 17' 2.750" Product: 1-3/4x14 VERSA-LAM 2.0 3100 SP 4 ply PASSES DESIGN CHECKS Design assumes continuous lateral bracing along the top chord. Design assumes continuous lateral bracing along the bottom chord. Allowable Stress Design Actual Allowable Capacity Location Loading Positive Moment 35661.'# 69451.'# 51% 8.79' Total Load D+S Shear 7177.# 21413.# 33% 16.54' Total Load D+S TL Deflection 0.5945" 0.8615" L/347 8.79' Total Load D+S LL Deflection 0.3727" 0.5743" L/554 8.79' Total Load S Control: TL Deflection DOLs: Live=100% Snow=115% Roof=125% Wind=160% Design assumes a repetitive member use increase in bending stress: 4 % Manufacturer's installation guide MUST be consulted for multi-ply connection details and alternatives CS Structure™ 2016.11 [Build 16] kmBeamEngine 2016.9.0.3 Materials Database 1557 AudetteLarryCooke - Level 8 6- 2-17 9:18am 2 of 8 All product names are trademarks of their respective owners Copyright (C) 2016 by Simpson Strong-Tie Company Inc. ALL RIGHTS RESERVED.**Passing is defined as when the member, floor joist, beam or girder, shown on this drawing meets applicable design criteria for Loads, Loading Conditions, and Spans listed on this sheet. The design must be reviewed by a qualified designer or design professional as required for approval. This design assumes product installation according to the manufacturer`s specifications. Doug Hodgins rk Miles Inc. 21 West St. West Hatfield Ma. Member Data Description: CalcG12 Member Type: Girder Application: Floor Comments:Top Lateral Bracing: Continuous Bottom Lateral Bracing: Continuous Standard Load: Moisture Condition: Dry Building Code: IBC/IRC Live Load: 0 PLF Deflection Criteria: L/360 live, L/240 total Dead Load: 0 PLF Deck Connection: Nailed Member Weight: 9.6 PLF Filename: C:\KMW\JOBS\ Other Loads Type (Description) Side Begin End Trib. Width Other Start End Dead Start End Category Replacement Uniform (PLF) Top 0' 0.00" 0' 8.00" 240 80 Live Replacement Uniform (PLF) Top 0' 8.00" 5' 8.00" 240 80 Live Replacement Uniform (PLF) Top 5' 8.00" 6' 1.50" 123 79 Live Replacement Uniform (PLF) Top 6' 1.50" 7' 10.00" 124 80 Live Point (LBS) Top 5' 8.00" 3 589 Live Point (LBS) Top 5' 8.00" 1130 0 Snow 1 2 7 10 0 7 10 0 Bearings and Reactions Input Min Gravity Gravity Location Type Material Length Required Reaction Uplift 1 0' 0.000" Wall SPF Plate (425psi) N/A 1.500" 1368# -- 2 7' 10.000" Wall SPF Plate (425psi) N/A 1.500" 1914# -- Maximum Load Case Reactions Used for applying point loads (or line loads) to carrying members Live Snow Dead 1 868# 301# 492# 2 699# 830# 767# Design spans 7' 5.750" Product: 1-3/4x9-1/2 VERSA-LAM 2.0 3100 SP 2 ply PASSES DESIGN CHECKS Design assumes continuous lateral bracing along the top chord. Design assumes continuous lateral bracing along the bottom chord. Allowable Stress Design Actual Allowable Capacity Location Loading Positive Moment 3466.'# 16051.'# 21% 5.41' Total Load D+0.75(L+S) Shear 1769.# 7265.# 24% 6.91' Total Load D+0.75(L+S) TL Deflection 0.0673" 0.3740" L/999+ 3.92' Total Load D+0.75(L+S) LL Deflection 0.0418" 0.2493" L/999+ 3.92' Total Load 0.75(L+S) Control: Shear DOLs: Live=100% Snow=115% Roof=125% Wind=160% Manufacturer's installation guide MUST be consulted for multi-ply connection details and alternatives CS Structure™ 2016.11 [Build 16] kmBeamEngine 2016.9.0.3 Materials Database 1557 AudetteLarryCooke - Level 8 6- 2-17 9:18am 3 of 8 All product names are trademarks of their respective owners Copyright (C) 2016 by Simpson Strong-Tie Company Inc. ALL RIGHTS RESERVED.**Passing is defined as when the member, floor joist, beam or girder, shown on this drawing meets applicable design criteria for Loads, Loading Conditions, and Spans listed on this sheet. The design must be reviewed by a qualified designer or design professional as required for approval. This design assumes product installation according to the manufacturer`s specifications. Doug Hodgins rk Miles Inc. 21 West St. West Hatfield Ma. Member Data Description: CalcG14 Member Type: Girder Application: Floor Comments:Top Lateral Bracing: Continuous Bottom Lateral Bracing: Continuous Standard Load: Moisture Condition: Dry Building Code: IBC/IRC Live Load: 0 PLF Deflection Criteria: L/360 live, L/240 total Dead Load: 0 PLF Deck Connection: Nailed Member Weight: 9.6 PLF Filename: C:\KMW\JOBS\ Other Loads Type (Description) Side Begin End Trib. Width Other Start End Dead Start End Category Replacement Uniform (PLF) Top 0' 0.00" 8' 3.00" 105 60 Live Replacement Uniform (PLF) Top 0' 6.25" 8' 3.00" 80 90 Live Replacement Uniform (PLF) Top 8' 3.00" 12' 3.00" 0 35 Live Replacement Uniform (PLF) Top 8' 3.00" 12' 3.00" 105 60 Live 1 2 12 3 0 12 3 0 Bearings and Reactions Input Min Gravity Gravity Location Type Material Length Required Reaction Uplift 1 0' 0.000" Wall SPF Plate (425psi) N/A 1.500" 1881# -- 2 12' 3.000" Wall SPF Plate (425psi) N/A 1.500" 1600# -- Maximum Load Case Reactions Used for applying point loads (or line loads) to carrying members Live Dead 1 1009# 871# 2 836# 764# Design spans 11' 8.250" Product: 1-3/4x9-1/2 VERSA-LAM 2.0 3100 SP 2 ply PASSES DESIGN CHECKS Design assumes continuous lateral bracing along the top chord. Design assumes continuous lateral bracing along the bottom chord. Allowable Stress Design Actual Allowable Capacity Location Loading Positive Moment 5438.'# 13958.'# 38% 6.02' Total Load D+L Shear 1666.# 6317.# 26% 0.19' Total Load D+L TL Deflection 0.2646" 0.5844" L/530 6.02' Total Load D+L LL Deflection 0.1407" 0.3896" L/996 6.02' Total Load L Control: TL Deflection DOLs: Live=100% Snow=115% Roof=125% Wind=160% Manufacturer's installation guide MUST be consulted for multi-ply connection details and alternatives CS Structure™ 2016.11 [Build 16] kmBeamEngine 2016.9.0.3 Materials Database 1557 AudetteLarryCooke - Level 8 6- 2-17 9:18am 4 of 8 All product names are trademarks of their respective owners Copyright (C) 2016 by Simpson Strong-Tie Company Inc. ALL RIGHTS RESERVED.**Passing is defined as when the member, floor joist, beam or girder, shown on this drawing meets applicable design criteria for Loads, Loading Conditions, and Spans listed on this sheet. The design must be reviewed by a qualified designer or design professional as required for approval. This design assumes product installation according to the manufacturer`s specifications. Doug Hodgins rk Miles Inc. 21 West St. West Hatfield Ma. Member Data Description: CalcG23 Member Type: Girder Application: Roof Comments:Top Lateral Bracing: Continuous Slope: 0.00 / 12 Bottom Lateral Bracing: Continuous Standard Load: Moisture Condition: Dry Building Code: IBC/IRC Live Load: 0 PLF Deflection Criteria: L/360 live, L/240 total Dead Load: 0 PLF Deck Connection: Nailed Member Weight: 36.5 PLF Filename: C:\KMW\JOBS\ Other Loads Type (Description) Side Begin End Trib. Width Other Start End Dead Start End Category Point (LBS) Top 0' 4.63" 104 0 Snow Point (LBS) Top 0' 4.63" 0 134 Live Point (LBS) Top 14' 0.44" 2 473 Live Point (LBS) Top 14' 0.44" 992 0 Snow Point (LBS) Top 20' 7.44" 21 420 Live Point (LBS) Top 20' 7.44" 940 0 Snow 1 2 21 0 1 21 0 1 Bearings and Reactions Input Min Gravity Gravity Location Type Material Length Required Reaction Uplift 1 0' 0.000" Wall SPF Plate (425psi) N/A 1.500" 1084# -- 2 21' 0.063" Wall SPF Plate (425psi) N/A 1.500" 2717# -- Maximum Load Case Reactions Used for applying point loads (or line loads) to carrying members Live Snow Dead 1 1# 426# 658# 2 22# 1609# 1109# Design spans 20' 2.812" Product: 1-3/4x24 VERSA-LAM 2.0 3100 SP 3 ply PASSES DESIGN CHECKS Design assumes continuous lateral bracing along the top chord. Design assumes continuous lateral bracing along the bottom chord. Allowable Stress Design Actual Allowable Capacity Location Loading Positive Moment 8143.'# 144176.'# 5% 14.04' Total Load D+S Shear 1284.# 27531.# 4% 19.61' Total Load D+S TL Deflection 0.0418" 1.0117" L/999+ 11.51' Total Load D+S LL Deflection 0.0207" 0.6744" L/999+ 11.51' Total Load S Control: Positive Moment DOLs: Live=100% Snow=115% Roof=125% Wind=160% Design assumes a repetitive member use increase in bending stress: 4 % Manufacturer's installation guide MUST be consulted for multi-ply connection details and alternatives CS Structure™ 2016.11 [Build 16] kmBeamEngine 2016.9.0.3 Materials Database 1557 AudetteLarryCooke - Level 8 6- 2-17 9:18am 5 of 8 All product names are trademarks of their respective owners Copyright (C) 2016 by Simpson Strong-Tie Company Inc. ALL RIGHTS RESERVED.**Passing is defined as when the member, floor joist, beam or girder, shown on this drawing meets applicable design criteria for Loads, Loading Conditions, and Spans listed on this sheet. The design must be reviewed by a qualified designer or design professional as required for approval. This design assumes product installation according to the manufacturer`s specifications. Doug Hodgins rk Miles Inc. 21 West St. West Hatfield Ma. Member Data Description: CalcG25 Member Type: Girder Application: Roof Comments:Top Lateral Bracing: Continuous Slope: 0.00 / 12 Bottom Lateral Bracing: Continuous Standard Load: Moisture Condition: Dry Building Code: IBC/IRC Live Load: 0 PLF Deflection Criteria: L/360 live, L/240 total Dead Load: 0 PLF Deck Connection: Nailed Member Weight: 18.1 PLF Filename: C:\KMW\JOBS\ Other Loads Type (Description) Side Begin End Trib. Width Other Start End Dead Start End Category Replacement Uniform (PLF) Top 0' 0.00" 4' 0.00" -53 -13 Live Replacement Uniform (PLF) Top 0' 0.00" 4' 0.00" 0 13 Live Replacement Uniform (PLF) Top 0' 0.00" 4' 0.00" 27 7 Live Replacement Uniform (PLF) Top 0' 0.00" 16' 2.75" 27 7 Live Replacement Uniform (PLF) Top 4' 0.00" 10' 0.00" -53 -13 Live Replacement Uniform (PLF) Top 4' 0.00" 10' 0.00" 13 13 Live Replacement Uniform (PLF) Top 4' 0.00" 16' 2.75" 27 7 Live Replacement Uniform (PLF) Top 10' 0.00" 16' 2.75" -53 -13 Live Replacement Uniform (PLF) Top 10' 0.00" 16' 2.75" 27 13 Live Point (LBS) Top 0' 4.63" -52 -15 Snow Point (LBS) Top 0' 4.63" 0 1 Live Point (LBS) Top 0' 4.63" 0 3 Live Point (LBS) Top 0' 4.63" 1 198 Live Point (LBS) Top 0' 4.63" 486 0 Snow Point (LBS) Top 0' 4.63" 4 573 Live Point (LBS) Top 0' 4.63" 1405 0 Snow 1 2 16 2 12 16 2 12 Bearings and Reactions Input Min Gravity Gravity Location Type Material Length Required Reaction Uplift 1 0' 0.000" Wall SPF Plate (425psi) N/A 1.500" 3013# -- 2 16' 2.750" Wall SPF Plate (425psi) N/A 1.500" 920# -374# Maximum Load Case Reactions Used for applying point loads (or line loads) to carrying members Live Snow Dead 1 493# 1839# 1107# 2 573# 0# 347# Design spans 15' 5.500" Product: 1-3/4x11-7/8 VERSA-LAM 2.0 3100 SP 3 ply PASSES DESIGN CHECKS Design assumes continuous lateral bracing along the top chord. Design assumes continuous lateral bracing along the bottom chord. Review gravity uplift reaction force of 374lbs at bearing 2 and ensure that the structure can resist appropriately. Allowable Stress Design Actual Allowable Capacity Location Loading Positive Moment 3402.'# 33189.'# 10% 8.11' Total Load D+L Negative Moment 1448.'# 33189.'# 4% 8.11' Total Load D+L Shear 796.# 11845.# 6% 15.07' Total Load D+L TL Deflection 0.0999" 0.7729" L/999+ 8.11' Total Load D+L LL Deflection 0.0606" 0.5153" L/999+ 8.11' Total Load L CS Structure™ 2016.11 [Build 16] kmBeamEngine 2016.9.0.3 Materials Database 1557 AudetteLarryCooke - Level 8 6- 2-17 9:18am 6 of 8 All product names are trademarks of their respective owners Copyright (C) 2016 by Simpson Strong-Tie Company Inc. ALL RIGHTS RESERVED.**Passing is defined as when the member, floor joist, beam or girder, shown on this drawing meets applicable design criteria for Loads, Loading Conditions, and Spans listed on this sheet. The design must be reviewed by a qualified designer or design professional as required for approval. This design assumes product installation according to the manufacturer`s specifications. Doug Hodgins rk Miles Inc. 21 West St. West Hatfield Ma. Control: TL Deflection DOLs: Live=100% Snow=115% Roof=125% Wind=160% Design assumes a repetitive member use increase in bending stress: 4 % Manufacturer's installation guide MUST be consulted for multi-ply connection details and alternatives CS Structure™ 2016.11 [Build 16] kmBeamEngine 2016.9.0.3 Materials Database 1557 AudetteLarryCooke - Level 8 6- 2-17 9:18am 7 of 8 All product names are trademarks of their respective owners Copyright (C) 2016 by Simpson Strong-Tie Company Inc. ALL RIGHTS RESERVED.**Passing is defined as when the member, floor joist, beam or girder, shown on this drawing meets applicable design criteria for Loads, Loading Conditions, and Spans listed on this sheet. The design must be reviewed by a qualified designer or design professional as required for approval. This design assumes product installation according to the manufacturer`s specifications. Doug Hodgins rk Miles Inc. 21 West St. West Hatfield Ma. Member Data Description: CalcG27 Member Type: Girder Application: Floor Comments:Top Lateral Bracing: Continuous Bottom Lateral Bracing: Continuous Standard Load: Moisture Condition: Dry Building Code: IBC/IRC Live Load: 0 PLF Deflection Criteria: L/360 live, L/240 total Dead Load: 0 PLF Deck Connection: Nailed Member Weight: 18.1 PLF Filename: C:\KMW\JOBS\ Other Loads Type (Description) Side Begin End Trib. Width Other Start End Dead Start End Category Replacement Uniform (PLF) Top 0' 0.00" 0' 8.50" 44 18 Snow Replacement Uniform (PLF) Top 0' 0.00" 14' 3.00" -53 -13 Live Replacement Uniform (PLF) Top 0' 0.00" 14' 3.00" 13 13 Live Replacement Uniform (PLF) Top 0' 8.50" 1' 8.50" 1 262 Live Replacement Uniform (PLF) Top 0' 8.50" 1' 8.50" 449 0 Snow Replacement Uniform (PLF) Top 1' 8.50" 2' 4.19" 1 265 Live Replacement Uniform (PLF) Top 1' 8.50" 2' 4.19" 458 0 Snow Replacement Uniform (PLF) Top 2' 4.19" 3' 4.19" 1 269 Live Replacement Uniform (PLF) Top 2' 4.19" 3' 4.19" 466 0 Snow Replacement Uniform (PLF) Top 3' 4.19" 4' 4.19" 1 273 Live Replacement Uniform (PLF) Top 3' 4.19" 4' 4.19" 477 0 Snow Replacement Uniform (PLF) Top 4' 4.19" 5' 4.19" 1 277 Live Replacement Uniform (PLF) Top 4' 4.19" 5' 4.19" 487 0 Snow Replacement Uniform (PLF) Top 5' 4.19" 6' 4.19" 1 281 Live Replacement Uniform (PLF) Top 5' 4.19" 6' 4.19" 497 0 Snow Replacement Uniform (PLF) Top 6' 4.19" 7' 4.75" 1 285 Live Replacement Uniform (PLF) Top 6' 4.19" 7' 4.75" 506 0 Snow Replacement Uniform (PLF) Top 7' 4.75" 14' 3.00" 2 334 Live Replacement Uniform (PLF) Top 7' 4.75" 14' 3.00" 633 0 Snow Point (LBS) Top 0' 5.75" 1 77 Live Point (LBS) Top 0' 5.75" 219 0 Snow Point (LBS) Top 13' 10.38" 0 1 Live Point (LBS) Top 13' 10.38" 1 76 Live Point (LBS) Top 13' 10.38" 219 0 Snow 1 2 14 3 0 14 3 0 Bearings and Reactions Input Min Gravity Gravity Location Type Material Length Required Reaction Uplift 1 0' 0.000" Wall SPF Plate (425psi) N/A 2.508" 5596# -330# 2 14' 3.000" Wall SPF Plate (425psi) N/A 3.023" 6745# -253# Maximum Load Case Reactions Used for applying point loads (or line loads) to carrying members Live Snow Dead 1 -364# 3481# 2116# 2 -363# 4275# 2469# Design spans 13' 8.250" Product: 1-3/4x11-7/8 VERSA-LAM 2.0 3100 SP 3 ply PASSES DESIGN CHECKS Design assumes continuous lateral bracing along the top chord. Design assumes continuous lateral bracing along the bottom chord. Review gravity uplift reaction force of 330lbs at bearing 1 and ensure that the structure can resist appropriately. Review gravity uplift reaction force of 253lbs at bearing 2 and ensure that the structure can resist appropriately. CS Structure™ 2016.11 [Build 16] kmBeamEngine 2016.9.0.3 Materials Database 1557 AudetteLarryCooke - Level 8 6- 2-17 9:18am 8 of 8 All product names are trademarks of their respective owners Copyright (C) 2016 by Simpson Strong-Tie Company Inc. ALL RIGHTS RESERVED.**Passing is defined as when the member, floor joist, beam or girder, shown on this drawing meets applicable design criteria for Loads, Loading Conditions, and Spans listed on this sheet. The design must be reviewed by a qualified designer or design professional as required for approval. This design assumes product installation according to the manufacturer`s specifications. Doug Hodgins rk Miles Inc. 21 West St. West Hatfield Ma. Allowable Stress Design Actual Allowable Capacity Location Loading Positive Moment 20827.'# 38167.'# 54% 7.41' Total Load D+S Negative Moment 1133.'# 33189.'# 3% 7.02' Total Load D+L Shear 5461.# 13622.# 40% 13.18' Total Load D+S TL Deflection 0.4781" 0.6844" L/343 7.02' Total Load D+S LL Deflection 0.2981" 0.4562" L/550 7.02' Total Load S Control: TL Deflection DOLs: Live=100% Snow=115% Roof=125% Wind=160% Design assumes a repetitive member use increase in bending stress: 4 % Manufacturer's installation guide MUST be consulted for multi-ply connection details and alternatives