Loading...
44 -135 P15919 1020 Florence Rd Northampton final air leakage reportAir Leakage Property Anthony Bombard 1020 Florence Rd Northampton, MA 01062 Weather:Chicopee, MA 1020 Florence Rd P15919 1020 Florence Rd Northampton-final.blg Organization Center for EcoTechnology 413-586-7350 John Saveson Builder Charles Amo Whole House Infiltration ASHRAE 62.2 - Ventilation Requirements The ASHRAE 62.2 flow rates shown above are the CONTINUOUS mechanical fresh air ventilation which will meet the 'whole-building' requirement under that version of the standard. Both values incorporate any appropriate 'infiltration credit'. Intermittent mechanical ventilation may be used if the flow rate is adjusted accordingly. For example, the runtime can be reduced to 12 hours per day using a doubled flow rate, as long as the system provides ventilation at least once every 3 hours. For more detail, refer to the appropriate standard. REM/Rate - Residential Energy Analysis and Rating Software v15.4.2 This information does not constitute any warranty of energy cost or savings. © 1985-2017 Noresco, Boulder, Colorado. HERS Confirmed 2018-06-05 Rating No:P15919 Rater ID:1911963 Duct Leakage Ventilation Blower Door Test Heating Cooling Natural ACH 0.12 0.10 ACH @ 50 Pascals 2.05 2.05 CFM @ 25 Pascals 559 559 CFM @ 50 Pascals 877 877 Eff. Leakage Area (sq.in) 48.1 48.1 Specific Leakage Area 0.00016 0.00016 ELA/100 sf shell (sq.in) 0.79 0.79 CFM50/sf shell 0.14 0.14 Leakage to Outside Units heating & cooling CFM @ 25 Pascals 29 CFM25 / CFMfan 0.0231 CFM25 / CFA 0.0136 CFM per Std 152 N/A CFM per Std 152 / CFA N/A CFM @ 50 Pascals 46 Eff. Leakage Area (sq.in) 2.50 Thermal Efficiency N/A Total Duct Leakage Units CFM25/CFA Total Duct Leakage 0.0907 Mechanical Balanced ASHRAE ASHRAE Sensible Recovery Eff. (%) 72.0 62.2-2010 62.2-2013 Total Recovery Eff. (%) 0.0 Rate (cfm)87 59 72 Hours/Day 16.8 24.0 24.0 Fan Watts 46.0 Cooling Ventilation Natural Ventilation Fuel Summary Property Anthony Bombard 1020 Florence Rd Northampton, MA 01062 Weather:Chicopee, MA 1020 Florence Rd P15919 1020 Florence Rd Northampton-final.blg Organization Center for EcoTechnology 413-586-7350 John Saveson Builder Charles Amo REM/Rate - Residential Energy Analysis and Rating Software v15.4.2 This information does not constitute any warranty of energy cost or savings. © 1985-2017 Noresco, Boulder, Colorado. HERS Confirmed 2018-06-05 Rating No:P15919 Rater ID:1911963 Annual Energy Cost $/yr Propane 1896 Electric 1364 Annual End-Use Cost $/yr Heating 1565 Cooling 91 Water Heating 376 Lights & Appliances 1227 Photovoltaics -0 Service Charge 0 Total 3259 Annual End-Use Consumption Heating (Gallons)498 Heating (kWh)208 Cooling (kWh)414 Water Heating (Gallons)123 Lights & Appliances (kWh)5577 Total (Gallons)621 Total (kWh)6199 Annual Energy Demands kW Heating 0.1 Cooling 1.1 Water Heating (Winter Peak)0.0 Water Heating (Summer Peak)0.0 Lights & Appliances (Winter Peak)0.4 Lights & Appliances (Summer Peak)1.1 Total Winter Peak 0.5 Total Summer Peak 2.2 Utility Rates Electricity Electricity 2018 Propane Propane 2018 RESNET Home Energy Rating Standard Disclosure REM/Rate - Residential Energy Analysis and Rating Software v15.4.2 This information does not constitute any warranty of energy cost or savings. © 1985-2017 Noresco, Boulder, Colorado. For home located at:1020 Florence Rd City:Northampton State:MA I attest that the above information is true and correct to the best of my knowledge. As a Rater or Rating Provider I abide by the rating quality control provisions of the Mortgage Industry National Home Energy Rating Standard as set forth by the Residential Energy Services Network (RESNET). The national rating quality control provisions of the rating standard are contained in Chapter One 4.C.8. of the standard and are posted at http://resnet.us/standards/RESNET_Mortgage_Industry_National_HERS_Standards.pdf. The Home Energy Rating Standard Disclosure for this home is available from the rating provider. John Saveson Rater's Printed Name 1911963 Certification # June 06, 2018 DateRater's Signature 1.X The Rater or Rater's employer is receiving a fee for providing the rating on this home. 2.In addition to the rating, the Rater or Rater's employer has also provided the following consulting services for this home. 3.X The Rater or Rater's employer is: 4.X The Rater or Rater's employer is a supplier or installer of products, which may include: Vendor of recycled building materials. RESNET Form 0300-2 5.This home has been verified under the provisions of Chapter 6, Section 603 'Technical Requirements for Sampling' of the Mortgage Industry National Home Energy Rating Standard as set forth by the Residential Energy Services Network (RESNET). Installed in this home by: OR is in the business of: HVAC Systems Rater Employer Rater Employer A. Mechanical system design A. The seller of this home or their agent Thermal Insulation Systems Rater Employer Rater Employer B. Moisture control or indoor air quality consulting B. The mortgagor for some portion of the financial payments on this home Air sealing of envelope or duct systems Rater Employer Rater Employer C. Performance testing and/or commissioning other than required for the rating itself X C. An employee, contractor or consultant of the electric and/or natural gas utility serving this home Windows or window shading systems Rater Employer Rater Employer D. Training for sales or construction personnel Energy efficient appliances Rater Employer Rater Employer E. Other (specify below) Construction (builder, developer, construction contractor, etc.) Rater Employer Rater Employer Other (specify below):Rater Employer Rater X Employer