Loading...
28 -021 porch Beam CalcsCS Structure™ 2.14.50 [Build 4] kmBeamEngine 4.13.4.1 Materials Database 1530 RossJdPurseglove091515 - Level 9-22-15 10:44am 1 of 3 All product names are trademarks of their respective owners Copyright (C) 2015 by Simpson Strong-Tie Company Inc. ALL RIGHTS RESERVED.**Passing is defined as when the member, floor joist, beam or girder, shown on this drawing meets applicable design criteria for Loads, Loading Conditions, and Spans listed on this sheet. The design must be reviewed by a qualified designer or design professional as required for approval. This design assumes product installation according to the manufacturer`s specifications. Doug Hodgins rk Miles Inc. 21 West St. West Hatfield Ma. Member Data Description: CalcB6 Member Type: Beam Application: Roof Comments:Top Lateral Bracing: Continuous Slope: 0.00 / 12 Bottom Lateral Bracing: Continuous Standard Load: Moisture Condition: Dry Building Code: IBC/IRC Live Load: 0 PLF Deflection Criteria: L/360 live, L/240 total Dead Load: 0 PLF Deck Connection: Nailed Member Weight: 4.4 PLF Filename: C:\KMW\JOBS\ Other Loads Type (Description) Side Begin End Trib. Width Other Start End Dead Start End Category Replacement Uniform (PLF) Top 0' 0.00" 12' 7.25" 1 76 Live Replacement Uniform (PLF) Top 0' 0.00" 12' 7.25" 227 0 Snow Point (LBS) Top 0' 2.63" 35 10 Snow 1 2 3 6 1 12 6 5 8 12 7 4 Bearings and Reactions Input Min Gravity Gravity Location Type Material Length Required Reaction Uplift 1 0' 0.000" Wall SPF Plate (425psi) N/A 1.500" 724# -- 2 6' 1.750" Wall SPF Plate (425psi) N/A 1.811" 2309# -- 3 12' 7.250" Wall SPF Plate (425psi) N/A 1.500" 707# -- Maximum Load Case Reactions Used for applying point loads (or line loads) to carrying members Live Snow Dead 1 1# 536# 187# 2 5# 1706# 603# 3 1# 522# 185# Design spans 5' 11.125" 6' 0.875" Product: Spruce-Pine-Fir #2 2 x 8 2 ply PASSES DESIGN CHECKS Design assumes continuous lateral bracing along the top chord. Design assumes continuous lateral bracing along the bottom chord. Allowable Stress Design Actual Allowable Capacity Location Loading Positive Moment 808.# 2645.# 30% 9.79' Total Load D+S Negative Moment 1386.# 2645.# 52% 6.15' Total Load D+S Shear 977.# 2251.# 43% 6.16' Total Load D+S LL Deflection 0.0223" 0.2024" L/999+ 9.79' Total Load S TL Deflection 0.0302" 0.3036" L/999+ 9.79' Total Load D+S Control: Negative Moment DOLs: Live=100% Snow=115% Roof=125% Wind=160% This member has been designed in accordance with NDS 2005 CS Structure™ 2.14.50 [Build 4] kmBeamEngine 4.13.4.1 Materials Database 1530 RossJdPurseglove091515 - Level 9-22-15 10:44am 2 of 3 All product names are trademarks of their respective owners Copyright (C) 2015 by Simpson Strong-Tie Company Inc. ALL RIGHTS RESERVED.**Passing is defined as when the member, floor joist, beam or girder, shown on this drawing meets applicable design criteria for Loads, Loading Conditions, and Spans listed on this sheet. The design must be reviewed by a qualified designer or design professional as required for approval. This design assumes product installation according to the manufacturer`s specifications. Doug Hodgins rk Miles Inc. 21 West St. West Hatfield Ma. Member Data Description: CalcB7 Member Type: Beam Application: Roof Comments:Top Lateral Bracing: Continuous Slope: 0.00 / 12 Bottom Lateral Bracing: Continuous Standard Load: Moisture Condition: Dry Building Code: IBC/IRC Live Load: 0 PLF Deflection Criteria: L/360 live, L/240 total Dead Load: 0 PLF Deck Connection: Nailed Member Weight: 4.4 PLF Filename: C:\KMW\JOBS\ Other Loads Type (Description) Side Begin End Trib. Width Other Start End Dead Start End Category Replacement Uniform (PLF) Top 0' 0.00" 12' 7.25" 1 76 Live Replacement Uniform (PLF) Top 0' 0.00" 12' 7.25" 227 0 Snow Point (LBS) Top 12' 4.63" 35 10 Snow 1 2 3 6 5 8 6 1 12 12 7 4 Bearings and Reactions Input Min Gravity Gravity Location Type Material Length Required Reaction Uplift 1 0' 0.000" Wall SPF Plate (425psi) N/A 1.500" 707# -- 2 6' 5.500" Wall SPF Plate (425psi) N/A 1.811" 2309# -- 3 12' 7.250" Wall SPF Plate (425psi) N/A 1.500" 724# -- Maximum Load Case Reactions Used for applying point loads (or line loads) to carrying members Live Snow Dead 1 1# 522# 185# 2 5# 1706# 603# 3 1# 536# 187# Design spans 6' 0.875" 5' 11.125" Product: Spruce-Pine-Fir #2 2 x 8 2 ply PASSES DESIGN CHECKS Design assumes continuous lateral bracing along the top chord. Design assumes continuous lateral bracing along the bottom chord. Allowable Stress Design Actual Allowable Capacity Location Loading Positive Moment 808.# 2645.# 30% 2.81' Total Load D+S Negative Moment 1386.# 2645.# 52% 6.46' Total Load D+S Shear 977.# 2251.# 43% 6.15' Total Load D+S LL Deflection 0.0223" 0.2024" L/999+ 2.81' Total Load S TL Deflection 0.0302" 0.3036" L/999+ 2.81' Total Load D+S Control: Negative Moment DOLs: Live=100% Snow=115% Roof=125% Wind=160% This member has been designed in accordance with NDS 2005 CS Structure™ 2.14.50 [Build 4] kmBeamEngine 4.13.4.1 Materials Database 1530 RossJdPurseglove091515 - Level 9-22-15 10:44am 3 of 3 All product names are trademarks of their respective owners Copyright (C) 2015 by Simpson Strong-Tie Company Inc. ALL RIGHTS RESERVED.**Passing is defined as when the member, floor joist, beam or girder, shown on this drawing meets applicable design criteria for Loads, Loading Conditions, and Spans listed on this sheet. The design must be reviewed by a qualified designer or design professional as required for approval. This design assumes product installation according to the manufacturer`s specifications. Doug Hodgins rk Miles Inc. 21 West St. West Hatfield Ma. Member Data Description: CalcB8 Member Type: Beam Application: Roof Comments:Top Lateral Bracing: Continuous Slope: 0.00 / 12 Bottom Lateral Bracing: Continuous Standard Load: Moisture Condition: Dry Building Code: IBC/IRC Live Load: 0 PLF Deflection Criteria: L/360 live, L/240 total Dead Load: 0 PLF Deck Connection: Nailed Member Weight: 4.4 PLF Filename: C:\KMW\JOBS\ Other Loads Type (Description) Side Begin End Trib. Width Other Start End Dead Start End Category Replacement Uniform (PLF) Top 0' 0.00" 5' 7.75" -23 -7 Snow Replacement Uniform (PLF) Top 0' 0.00" 5' 7.75" 71 20 Snow Replacement Uniform (PLF) Top 0' 0.00" 11' 3.50" 4 1 Snow Replacement Uniform (PLF) Top 0' 0.00" 11' 3.50" 23 7 Snow Replacement Uniform (PLF) Top 5' 7.75" 11' 3.50" -23 -7 Snow Replacement Uniform (PLF) Top 5' 7.75" 11' 3.50" 71 20 Snow 1 2 11 3 8 11 3 8 Bearings and Reactions Input Min Gravity Gravity Location Type Material Length Required Reaction Uplift 1 0' 0.000" Wall SPF Plate (425psi) N/A 1.500" 716# -137# 2 11' 3.500" Wall SPF Plate (425psi) N/A 1.500" 716# -137# Maximum Load Case Reactions Used for applying point loads (or line loads) to carrying members Snow Dead 1 538# 178# 2 538# 178# Design spans 10' 10.250" Product: Spruce-Pine-Fir #2 2 x 8 2 ply PASSES DESIGN CHECKS Design assumes continuous lateral bracing along the top chord. Design assumes continuous lateral bracing along the bottom chord. Allowable Stress Design Actual Allowable Capacity Location Loading Positive Moment 1944.# 2645.# 73% 5.65' Total Load D+S Negative Moment 376.# 2645.# 14% 5.65' Total Load D+S Shear 637.# 2251.# 28% 10.53' Total Load D+S LL Deflection 0.2322" 0.3618" L/560 5.65' Total Load S TL Deflection 0.3091" 0.5427" L/421 5.65' Total Load D+S Control: Positive Moment DOLs: Live=100% Snow=115% Roof=125% Wind=160% This member has been designed in accordance with NDS 2005