Loading...
28 -021 First floor Beam CalcsCS Structure™ 2.14.50 [Build 4] kmBeamEngine 4.13.4.1 Materials Database 1530 RossJdPurseglove091515 - Level 9-22-15 10:36am 1 of 3 All product names are trademarks of their respective owners Copyright (C) 2015 by Simpson Strong-Tie Company Inc. ALL RIGHTS RESERVED.**Passing is defined as when the member, floor joist, beam or girder, shown on this drawing meets applicable design criteria for Loads, Loading Conditions, and Spans listed on this sheet. The design must be reviewed by a qualified designer or design professional as required for approval. This design assumes product installation according to the manufacturer`s specifications. Doug Hodgins rk Miles Inc. 21 West St. West Hatfield Ma. Member Data Description: CalcB1 Member Type: Beam Application: Floor Comments:Top Lateral Bracing: Continuous Bottom Lateral Bracing: Continuous Standard Load: Moisture Condition: Dry Building Code: IBC/IRC Live Load: 0 PLF Deflection Criteria: L/360 live, L/240 total Dead Load: 0 PLF Deck Connection: Nailed Member Weight: 14.0 PLF Filename: C:\KMW\JOBS\ Other Loads Type (Description) Side Begin End Trib. Width Other Start End Dead Start End Category Replacement Uniform (PLF) Top 0' 0.00" 7' 3.88" 678 169 Live Replacement Uniform (PLF) Top 7' 3.88" 15' 9.88" 678 169 Live Replacement Uniform (PLF) Top 15' 9.88" 23' 1.75" 678 169 Live Point (LBS) Top 0' 4.63" 0 219 Live 1 2 3 1 2 8 10 7 2 11 4 2 23 1 12 Bearings and Reactions Input Min Gravity Gravity Location Type Material Length Required Reaction Uplift 1 1' 2.500" Wall SPF Plate (425psi) N/A 2.068" 4613# -- 2 11' 9.625" Wall SPF Plate (425psi) N/A 5.198" 11598# -- 3 23' 1.750" Wall SPF Plate (425psi) N/A 1.798" 4011# -- Maximum Load Case Reactions Used for applying point loads (or line loads) to carrying members Live Dead 1 3735# 879# 2 9135# 2464# 3 3248# 764# Design spans 0' 9.875" (left cant) 10' 7.125" 10' 11.500" Product: 1-3/4x9-1/2 VERSA-LAM 2.0 3100 SP 3 ply PASSES DESIGN CHECKS Design assumes continuous lateral bracing along the top chord. Design assumes continuous lateral bracing along the bottom chord. Allowable Stress Design Actual Allowable Capacity Location Loading Positive Moment 9307.# 21774.# 42% 18.38' Odd Spans D+L Negative Moment 12500.# 21774.# 57% 11.8' Adjacent 2 D+L Shear 5179.# 9476.# 54% 11.81' Adjacent 2 D+L TL Deflection 0.2396" 0.5479" L/548 17.83' Odd Spans D+L LL Deflection 0.2050" 0.3653" L/641 17.83' Odd Spans L TL Defl., Lt. -0.0559" 0.2000" 2L/353 0' Even Spans D+L LL Defl., Lt. -0.0480" 0.2000" 2L/411 0' Even Spans L Control: Negative Moment DOLs: Live=100% Snow=115% Roof=125% Wind=160% Design assumes a repetitive member use increase in bending stress: 4 % Manufacturer's installation guide MUST be consulted for multi-ply connection details and alternatives CS Structure™ 2.14.50 [Build 4] kmBeamEngine 4.13.4.1 Materials Database 1530 RossJdPurseglove091515 - Level 9-22-15 10:36am 2 of 3 All product names are trademarks of their respective owners Copyright (C) 2015 by Simpson Strong-Tie Company Inc. ALL RIGHTS RESERVED.**Passing is defined as when the member, floor joist, beam or girder, shown on this drawing meets applicable design criteria for Loads, Loading Conditions, and Spans listed on this sheet. The design must be reviewed by a qualified designer or design professional as required for approval. This design assumes product installation according to the manufacturer`s specifications. Doug Hodgins rk Miles Inc. 21 West St. West Hatfield Ma. Member Data Description: CalcB5 Member Type: Beam Application: Floor Comments:Top Lateral Bracing: Continuous Bottom Lateral Bracing: Continuous Standard Load: Moisture Condition: Dry Building Code: IBC/IRC Live Load: 0 PLF Deflection Criteria: L/360 live, L/240 total Dead Load: 0 PLF Deck Connection: Nailed Member Weight: 13.2 PLF Filename: C:\KMW\JOBS\ Other Loads Type (Description) Side Begin End Trib. Width Other Start End Dead Start End Category Replacement Uniform (PLF) Top 0' 0.00" 12' 8.25" 220 55 Live Point (LBS) Top 0' 4.63" 2 479 Live Point (LBS) Top 0' 4.63" 994 0 Snow Point (LBS) Top 6' 2.75" 5 675 Live Point (LBS) Top 6' 2.75" 1706 0 Snow 1 2 10 8 12 1 11 8 12 8 4 Bearings and Reactions Input Min Gravity Gravity Location Type Material Length Required Reaction Uplift 1 0' 0.000" Wall SPF Plate (425psi) N/A 1.713" 3275# -- 2 10' 8.750" Wall SPF Plate (425psi) N/A 1.500" 2707# -- Maximum Load Case Reactions Used for applying point loads (or line loads) to carrying members Live Snow Dead 1 1142# 1736# 1117# 2 1513# 964# 849# Design spans 10' 4.125" 1' 6.875" (right cant) Product: SYP (PT MCA) #1 2 x 12 3 ply PASSES DESIGN CHECKS Design assumes continuous lateral bracing along the top chord. Design assumes continuous lateral bracing along the bottom chord. Allowable Stress Design Actual Allowable Capacity Location Loading Positive Moment 7997.# 10461.# 76% 6.23' Odd Spans D+0.75(L+S) Negative Moment 357.# 9097.# 3% 10.73' Total Load D+L Shear 2122.# 6792.# 31% 10.21' Total Load D+0.75(L+S) LL Deflection 0.1018" 0.3448" L/999+ 5.56' Odd Spans 0.75(L+S) TL Deflection 0.1490" 0.5172" L/833 5.56' Odd Spans D+0.75(L+S) LL Defl., Rt. -0.0491" 0.2000" 2L/768 12.69' Odd Spans 0.75(L+S) TL Defl., Rt. -0.0714" 0.2000" 2L/528 12.69' Odd Spans D+0.75(L+S) Control: Positive Moment DOLs: Live=100% Snow=115% Roof=125% Wind=160% Design assumes a repetitive member use increase in bending stress: 15 % This member has been designed in accordance with NDS 2005 CS Structure™ 2.14.50 [Build 4] kmBeamEngine 4.13.4.1 Materials Database 1530 RossJdPurseglove091515 - Level 9-22-15 10:36am 3 of 3 All product names are trademarks of their respective owners Copyright (C) 2015 by Simpson Strong-Tie Company Inc. ALL RIGHTS RESERVED.**Passing is defined as when the member, floor joist, beam or girder, shown on this drawing meets applicable design criteria for Loads, Loading Conditions, and Spans listed on this sheet. The design must be reviewed by a qualified designer or design professional as required for approval. This design assumes product installation according to the manufacturer`s specifications. Doug Hodgins rk Miles Inc. 21 West St. West Hatfield Ma. Member Data Description: CalcB6 Member Type: Beam Application: Floor Comments:Top Lateral Bracing: Continuous Bottom Lateral Bracing: Continuous Standard Load: Moisture Condition: Dry Building Code: IBC/IRC Live Load: 0 PLF Deflection Criteria: L/360 live, L/240 total Dead Load: 0 PLF Deck Connection: Nailed Member Weight: 13.2 PLF Filename: C:\KMW\JOBS\ Other Loads Type (Description) Side Begin End Trib. Width Other Start End Dead Start End Category Replacement Uniform (PLF) Top 0' 0.00" 12' 8.25" 220 55 Live Point (LBS) Top 6' 5.50" 5 675 Live Point (LBS) Top 6' 5.50" 1706 0 Snow Point (LBS) Top 12' 3.63" 2 479 Live Point (LBS) Top 12' 3.63" 994 0 Snow 1 2 1 11 8 10 8 12 12 8 4 Bearings and Reactions Input Min Gravity Gravity Location Type Material Length Required Reaction Uplift 1 1' 11.500" Wall SPF Plate (425psi) N/A 1.500" 2707# -- 2 12' 8.250" Wall SPF Plate (425psi) N/A 1.713" 3275# -- Maximum Load Case Reactions Used for applying point loads (or line loads) to carrying members Live Snow Dead 1 1513# 964# 849# 2 1142# 1736# 1117# Design spans 1' 6.875" (left cant) 10' 4.125" Product: SYP (PT MCA) #1 2 x 12 3 ply PASSES DESIGN CHECKS Design assumes continuous lateral bracing along the top chord. Design assumes continuous lateral bracing along the bottom chord. Allowable Stress Design Actual Allowable Capacity Location Loading Positive Moment 7997.# 10461.# 76% 6.46' Even Spans D+0.75(L+S) Negative Moment 357.# 9097.# 3% 1.96' Total Load D+L Shear 2122.# 6792.# 31% 1.97' Total Load D+0.75(L+S) LL Deflection 0.1018" 0.3448" L/999+ 7.13' Even Spans 0.75(L+S) TL Deflection 0.1489" 0.5172" L/833 7.13' Even Spans D+0.75(L+S) LL Defl., Lt. -0.0491" 0.2000" 2L/768 0' Even Spans 0.75(L+S) TL Defl., Lt. -0.0714" 0.2000" 2L/528 0' Even Spans D+0.75(L+S) Control: Positive Moment DOLs: Live=100% Snow=115% Roof=125% Wind=160% Design assumes a repetitive member use increase in bending stress: 15 % This member has been designed in accordance with NDS 2005