Loading...
21 -004 CS Header Beam CalcsCS Structure™ 2016.5.1 [Build 2] kmBeamEngine 2016.5.0.2 Materials Database 1555 KeiterScottKeiter - Level 8 7-29-16 1:29pm 1 of 6 All product names are trademarks of their respective owners Copyright (C) 2016 by Simpson Strong-Tie Company Inc. ALL RIGHTS RESERVED.**Passing is defined as when the member, floor joist, beam or girder, shown on this drawing meets applicable design criteria for Loads, Loading Conditions, and Spans listed on this sheet. The design must be reviewed by a qualified designer or design professional as required for approval. This design assumes product installation according to the manufacturer`s specifications. Doug Hodgins rk Miles Inc. 21 West St. West Hatfield Ma. Member Data Description: CalcB1 Member Type: Beam Application: Floor Comments:Top Lateral Bracing: Continuous Bottom Lateral Bracing: Continuous Standard Load: Moisture Condition: Dry Building Code: IBC/IRC Live Load: 0 PLF Deflection Criteria: L/360 live, L/240 total Dead Load: 0 PLF Deck Connection: Nailed Member Weight: 18.1 PLF Filename: C:\KMW\JOBS\ Other Loads Type (Description) Side Begin End Trib. Width Other Start End Dead Start End Category Replacement Uniform (PLF) Top 0' 0.00" 11' 4.50" 27 7 Live Replacement Uniform (PLF) Top 0' 0.00" 14' 3.00" -53 -13 Live Replacement Uniform (PLF) Top 0' 0.00" 14' 3.00" 27 7 Live Replacement Uniform (PLF) Top 0' 0.00" 14' 3.00" 40 13 Live Replacement Uniform (PLF) Top 0' 0.00" 14' 3.00" 47 15 Snow Replacement Uniform (PLF) Top 11' 4.50" 14' 3.00" 27 7 Live Point (LBS) Top 7' 1.50" 5 900 Live Point (LBS) Top 7' 1.50" 1917 0 Snow 1 2 14 3 0 14 3 0 Bearings and Reactions Input Min Gravity Gravity Location Type Material Length Required Reaction Uplift 1 0' 0.000" Wall SPF Plate (425psi) N/A 1.500" 2334# -341# 2 14' 3.000" Wall SPF Plate (425psi) N/A 1.500" 2334# -341# Maximum Load Case Reactions Used for applying point loads (or line loads) to carrying members Live Snow Dead 1 663# 1288# 871# 2 663# 1288# 871# Design spans 14' 1.750" Product: 1-3/4x11-7/8 VERSA-LAM 2.0 3100 SP 3 ply PASSES DESIGN CHECKS Design assumes continuous lateral bracing along the top chord. Design assumes continuous lateral bracing along the bottom chord. Review gravity uplift reaction force of 341lbs at bearing 1 and ensure that the structure can resist appropriately. Review gravity uplift reaction force of 341lbs at bearing 2 and ensure that the structure can resist appropriately. Allowable Stress Design Actual Allowable Capacity Location Loading Positive Moment 12616.'# 38167.'# 33% 7.12' Total Load D+S Negative Moment 1209.'# 33189.'# 3% 7.12' Total Load D+L Shear 2171.# 13622.# 15% 0.06' Total Load D+0.75(L+S) TL Deflection 0.2639" 0.7073" L/643 7.12' Total Load D+0.75(L+S) LL Deflection 0.1648" 0.4715" L/999+ 7.12' Total Load 0.75(L+S) Control: TL Deflection DOLs: Live=100% Snow=115% Roof=125% Wind=160% Design assumes a repetitive member use increase in bending stress: 4 % Manufacturer's installation guide MUST be consulted for multi-ply connection details and alternatives CS Structure™ 2016.5.1 [Build 2] kmBeamEngine 2016.5.0.2 Materials Database 1555 KeiterScottKeiter - Level 8 7-29-16 1:29pm 2 of 6 All product names are trademarks of their respective owners Copyright (C) 2016 by Simpson Strong-Tie Company Inc. ALL RIGHTS RESERVED.**Passing is defined as when the member, floor joist, beam or girder, shown on this drawing meets applicable design criteria for Loads, Loading Conditions, and Spans listed on this sheet. The design must be reviewed by a qualified designer or design professional as required for approval. This design assumes product installation according to the manufacturer`s specifications. Doug Hodgins rk Miles Inc. 21 West St. West Hatfield Ma. Member Data Description: CalcB15 Member Type: Beam Application: Floor Comments:Top Lateral Bracing: Continuous Bottom Lateral Bracing: Continuous Standard Load: Moisture Condition: Dry Building Code: IBC/IRC Live Load: 0 PLF Deflection Criteria: L/360 live, L/240 total Dead Load: 0 PLF Deck Connection: Nailed Member Weight: 12.0 PLF Filename: C:\KMW\JOBS\ Other Loads Type (Description) Side Begin End Trib. Width Other Start End Dead Start End Category Replacement Uniform (PLF) Top 0' 0.00" 6' 3.00" 27 7 Live Replacement Uniform (PLF) Top 0' 0.00" 10' 3.00" -53 -13 Live Replacement Uniform (PLF) Top 0' 0.00" 10' 3.00" 9 2 Live Replacement Uniform (PLF) Top 0' 0.00" 10' 3.00" 27 13 Live Replacement Uniform (PLF) Top 0' 0.00" 10' 3.00" 1 112 Live Replacement Uniform (PLF) Top 0' 0.00" 10' 3.00" 318 0 Snow Replacement Uniform (PLF) Top 6' 3.00" 10' 3.00" 27 7 Live 1 2 10 3 0 10 3 0 Bearings and Reactions Input Min Gravity Gravity Location Type Material Length Required Reaction Uplift 1 0' 0.000" Wall SPF Plate (425psi) N/A 1.583" 2355# -275# 2 10' 3.000" Wall SPF Plate (425psi) N/A 1.583" 2355# -275# Maximum Load Case Reactions Used for applying point loads (or line loads) to carrying members Live Snow Dead 1 322# 1612# 743# 2 322# 1612# 743# Design spans 10' 1.750" Product: 1-3/4x11-7/8 VERSA-LAM 2.0 3100 SP 2 ply PASSES DESIGN CHECKS Minimum 1.58" bearing required at bearing # 1 Minimum 1.58" bearing required at bearing # 2 Design assumes continuous lateral bracing along the top chord. Design assumes continuous lateral bracing along the bottom chord. Review gravity uplift reaction force of 276lbs at bearing 1 and ensure that the structure can resist appropriately. Review gravity uplift reaction force of 276lbs at bearing 2 and ensure that the structure can resist appropriately. Allowable Stress Design Actual Allowable Capacity Location Loading Positive Moment 5974.'# 24466.'# 24% 5.13' Total Load D+S Negative Moment 701.'# 21275.'# 3% 5.13' Total Load D+L Shear 1896.# 9081.# 20% 9.69' Total Load D+S TL Deflection 0.1133" 0.5073" L/999+ 5.13' Total Load D+S LL Deflection 0.0776" 0.3382" L/999+ 5.13' Total Load S Control: Positive Moment DOLs: Live=100% Snow=115% Roof=125% Wind=160% Manufacturer's installation guide MUST be consulted for multi-ply connection details and alternatives CS Structure™ 2016.5.1 [Build 2] kmBeamEngine 2016.5.0.2 Materials Database 1555 KeiterScottKeiter - Level 8 7-29-16 1:29pm 3 of 6 All product names are trademarks of their respective owners Copyright (C) 2016 by Simpson Strong-Tie Company Inc. ALL RIGHTS RESERVED.**Passing is defined as when the member, floor joist, beam or girder, shown on this drawing meets applicable design criteria for Loads, Loading Conditions, and Spans listed on this sheet. The design must be reviewed by a qualified designer or design professional as required for approval. This design assumes product installation according to the manufacturer`s specifications. Doug Hodgins rk Miles Inc. 21 West St. West Hatfield Ma. Member Data Description: CalcB16 Member Type: Beam Application: Floor Comments:Top Lateral Bracing: Continuous Bottom Lateral Bracing: Continuous Standard Load: Moisture Condition: Dry Building Code: IBC/IRC Live Load: 0 PLF Deflection Criteria: L/360 live, L/240 total Dead Load: 0 PLF Deck Connection: Nailed Member Weight: 12.0 PLF Filename: C:\KMW\JOBS\ Other Loads Type (Description) Side Begin End Trib. Width Other Start End Dead Start End Category Replacement Uniform (PLF) Top 0' 0.00" 0' 7.50" 27 7 Live Replacement Uniform (PLF) Top 0' 0.00" 10' 3.00" -53 -13 Live Replacement Uniform (PLF) Top 0' 0.00" 10' 3.00" 9 2 Live Replacement Uniform (PLF) Top 0' 0.00" 10' 3.00" 27 13 Live Replacement Uniform (PLF) Top 0' 0.00" 10' 3.00" 1 115 Live Replacement Uniform (PLF) Top 0' 0.00" 10' 3.00" 318 0 Snow Replacement Uniform (PLF) Top 0' 7.50" 5' 1.50" 27 7 Live Replacement Uniform (PLF) Top 5' 1.50" 6' 10.50" 27 7 Live Replacement Uniform (PLF) Top 6' 10.50" 10' 3.00" 27 7 Live 1 2 10 3 0 10 3 0 Bearings and Reactions Input Min Gravity Gravity Location Type Material Length Required Reaction Uplift 1 0' 0.000" Wall SPF Plate (425psi) N/A 1.592" 2369# -275# 2 10' 3.000" Wall SPF Plate (425psi) N/A 1.592" 2369# -275# Maximum Load Case Reactions Used for applying point loads (or line loads) to carrying members Live Snow Dead 1 322# 1613# 756# 2 322# 1613# 756# Design spans 10' 1.750" Product: 1-3/4x11-7/8 VERSA-LAM 2.0 3100 SP 2 ply PASSES DESIGN CHECKS Minimum 1.59" bearing required at bearing # 1 Minimum 1.59" bearing required at bearing # 2 Design assumes continuous lateral bracing along the top chord. Design assumes continuous lateral bracing along the bottom chord. Review gravity uplift reaction force of 276lbs at bearing 1 and ensure that the structure can resist appropriately. Review gravity uplift reaction force of 276lbs at bearing 2 and ensure that the structure can resist appropriately. Allowable Stress Design Actual Allowable Capacity Location Loading Positive Moment 6008.'# 24466.'# 24% 5.12' Total Load D+S Negative Moment 701.'# 21275.'# 3% 5.12' Total Load D+L Shear 1907.# 9081.# 20% 9.69' Total Load D+S TL Deflection 0.1140" 0.5073" L/999+ 5.12' Total Load D+S LL Deflection 0.0776" 0.3382" L/999+ 5.12' Total Load S Control: Positive Moment DOLs: Live=100% Snow=115% Roof=125% Wind=160% Manufacturer's installation guide MUST be consulted for multi-ply connection details and alternatives CS Structure™ 2016.5.1 [Build 2] kmBeamEngine 2016.5.0.2 Materials Database 1555 KeiterScottKeiter - Level 8 7-29-16 1:29pm 4 of 6 All product names are trademarks of their respective owners Copyright (C) 2016 by Simpson Strong-Tie Company Inc. ALL RIGHTS RESERVED.**Passing is defined as when the member, floor joist, beam or girder, shown on this drawing meets applicable design criteria for Loads, Loading Conditions, and Spans listed on this sheet. The design must be reviewed by a qualified designer or design professional as required for approval. This design assumes product installation according to the manufacturer`s specifications. Doug Hodgins rk Miles Inc. 21 West St. West Hatfield Ma. Member Data Description: CalcB17 Member Type: Beam Application: Floor Comments:Top Lateral Bracing: Continuous Bottom Lateral Bracing: Continuous Standard Load: Moisture Condition: Dry Building Code: IBC/IRC Live Load: 0 PLF Deflection Criteria: L/360 live, L/240 total Dead Load: 0 PLF Deck Connection: Nailed Member Weight: 12.0 PLF Filename: C:\KMW\JOBS\ Other Loads Type (Description) Side Begin End Trib. Width Other Start End Dead Start End Category Replacement Uniform (PLF) Top 0' 0.00" 1' 11.00" 79 24 Snow Replacement Uniform (PLF) Top 0' 0.00" 7' 10.00" 27 7 Live Replacement Uniform (PLF) Top 0' 0.00" 23' 10.00" -53 -13 Live Replacement Uniform (PLF) Top 0' 0.00" 23' 10.00" 9 2 Live Replacement Uniform (PLF) Top 0' 0.00" 23' 10.00" 27 13 Live Replacement Uniform (PLF) Top 1' 11.00" 10' 11.00" 79 24 Snow Replacement Uniform (PLF) Top 7' 10.00" 23' 10.00" 27 7 Live Replacement Uniform (PLF) Top 10' 11.00" 12' 11.00" 79 24 Snow Replacement Uniform (PLF) Top 12' 11.00" 21' 11.00" 79 24 Snow Replacement Uniform (PLF) Top 21' 11.00" 23' 10.00" 79 24 Snow Point (LBS) Top 0' 0.63" 0 2 Live Point (LBS) Top 0' 0.63" 1 167 Live Point (LBS) Top 0' 0.63" 408 0 Snow Point (LBS) Top 11' 11.00" 16 2457 Live Point (LBS) Top 11' 11.00" 5759 0 Snow Point (LBS) Top 23' 9.38" 1 170 Live Point (LBS) Top 23' 9.38" 408 0 Snow 1 2 3 4 1 11 0 9 0 0 2 0 0 9 0 0 1 11 0 23 10 0 Bearings and Reactions Input Min Gravity Gravity Location Type Material Length Required Reaction Uplift 1 1' 11.000" Wall SPF Plate (425psi) N/A 1.500" 937# -315# 2 10' 11.000" Wall SPF Plate (425psi) N/A 3.647" 5425# -613# 3 12' 11.000" Wall SPF Plate (425psi) N/A 3.648" 5426# -613# 4 21' 11.000" Wall SPF Plate (425psi) N/A 1.500" 937# -315# Maximum Load Case Reactions Used for applying point loads (or line loads) to carrying members Live Snow Dead 1 362# 460# 320# 2 720# 3824# 1601# 3 720# 3825# 1601# 4 362# 460# 320# Design spans 1' 10.375" (left cant) 9' 0.000" 2' 0.000" 9' 0.000" 1' 10.375" (right cant) Product: 1-3/4x11-7/8 VERSA-LAM 2.0 3100 SP 2 ply PASSES DESIGN CHECKS Minimum 3.65" bearing required at bearing # 2 Minimum 3.65" bearing required at bearing # 3 Design assumes continuous lateral bracing along the top chord. Design assumes continuous lateral bracing along the bottom chord. Review gravity uplift reaction force of 315lbs at bearing 1 and ensure that the structure can resist appropriately. Review gravity uplift reaction force of 614lbs at bearing 2 and ensure that the structure can resist appropriately. Review gravity uplift reaction force of 614lbs at bearing 3 and ensure that the structure can resist appropriately. Review gravity uplift reaction force of 315lbs at bearing 4 and ensure that the structure can resist appropriately. CS Structure™ 2016.5.1 [Build 2] kmBeamEngine 2016.5.0.2 Materials Database 1555 KeiterScottKeiter - Level 8 7-29-16 1:29pm 5 of 6 All product names are trademarks of their respective owners Copyright (C) 2016 by Simpson Strong-Tie Company Inc. ALL RIGHTS RESERVED.**Passing is defined as when the member, floor joist, beam or girder, shown on this drawing meets applicable design criteria for Loads, Loading Conditions, and Spans listed on this sheet. The design must be reviewed by a qualified designer or design professional as required for approval. This design assumes product installation according to the manufacturer`s specifications. Doug Hodgins rk Miles Inc. 21 West St. West Hatfield Ma. Allowable Stress Design Actual Allowable Capacity Location Loading Positive Moment 3387.'# 24466.'# 13% 11.92' Odd Spans D+S Negative Moment 1739.'# 24466.'# 7% 12.92' Adjacent 3 D+0.75(L+S) Shear 4503.# 9081.# 49% 12.02' Adjacent 3 D+S TL Deflection 0.0119" 0.4500" L/999+ 5.97' Even Spans D+0.75(L+S) LL Deflection 0.0090" 0.3000" L/999+ 5.97' Even Spans 0.75(L+S) TL Defl., Lt. -0.0086" 0.2000" 2L/999+ 0' Even Spans D+0.75(L+S) LL Defl., Lt. -0.0067" 0.2000" 2L/999+ 0' Even Spans 0.75(L+S) TL Defl., Rt. -0.0086" 0.2000" 2L/999+ 23.83' Even Spans D+0.75(L+S) LL Defl., Rt. -0.0067" 0.2000" 2L/999+ 23.83' Even Spans 0.75(L+S) Control: Shear DOLs: Live=100% Snow=115% Roof=125% Wind=160% Manufacturer's installation guide MUST be consulted for multi-ply connection details and alternatives CS Structure™ 2016.5.1 [Build 2] kmBeamEngine 2016.5.0.2 Materials Database 1555 KeiterScottKeiter - Level 8 7-29-16 1:29pm 6 of 6 All product names are trademarks of their respective owners Copyright (C) 2016 by Simpson Strong-Tie Company Inc. ALL RIGHTS RESERVED.**Passing is defined as when the member, floor joist, beam or girder, shown on this drawing meets applicable design criteria for Loads, Loading Conditions, and Spans listed on this sheet. The design must be reviewed by a qualified designer or design professional as required for approval. This design assumes product installation according to the manufacturer`s specifications. Doug Hodgins rk Miles Inc. 21 West St. West Hatfield Ma. Member Data Description: CalcB21 Member Type: Beam Application: Floor Comments:Top Lateral Bracing: Continuous Bottom Lateral Bracing: Continuous Standard Load: Moisture Condition: Dry Building Code: IBC/IRC Live Load: 0 PLF Deflection Criteria: L/360 live, L/240 total Dead Load: 0 PLF Deck Connection: Nailed Member Weight: 9.6 PLF Filename: C:\KMW\JOBS\ Other Loads Type (Description) Side Begin End Trib. Width Other Start End Dead Start End Category Replacement Uniform (PLF) Top 0' 0.00" 3' 6.00" 410 0 Snow Replacement Uniform (PLF) Top 0' 0.00" 3' 6.00" 150 283 Live Replacement Uniform (PLF) Top 3' 6.00" 6' 3.00" -53 -13 Live Replacement Uniform (PLF) Top 3' 6.00" 6' 3.00" 9 2 Live Replacement Uniform (PLF) Top 3' 6.00" 6' 3.00" 13 13 Live Replacement Uniform (PLF) Top 3' 6.00" 6' 3.00" 27 7 Live Replacement Uniform (PLF) Top 3' 6.00" 6' 3.00" 1 109 Live Replacement Uniform (PLF) Top 3' 6.00" 6' 3.00" 265 0 Snow Point (LBS) Top 3' 3.25" 93 189 Snow Point (LBS) Top 3' 4.25" 229 0 Snow Point (LBS) Top 3' 4.25" 114 645 Live 1 2 6 3 0 6 3 0 Bearings and Reactions Input Min Gravity Gravity Location Type Material Length Required Reaction Uplift 1 0' 0.000" Wall SPF Plate (425psi) N/A 1.702" 2532# -8# 2 6' 3.000" Wall SPF Plate (425psi) N/A 1.500" 2152# -109# Maximum Load Case Reactions Used for applying point loads (or line loads) to carrying members Live Snow Dead 1 455# 1323# 1198# 2 312# 1126# 1026# Design spans 6' 1.750" Product: 1-3/4x9-1/2 VERSA-LAM 2.0 3100 SP 2 ply PASSES DESIGN CHECKS Minimum 1.70" bearing required at bearing # 1 Design assumes continuous lateral bracing along the top chord. Design assumes continuous lateral bracing along the bottom chord. Allowable Stress Design Actual Allowable Capacity Location Loading Positive Moment 4477.'# 16051.'# 27% 3.27' Total Load D+S Negative Moment 106.'# 13958.'# 0% 4.35' Total Load D+L Shear 1968.# 7265.# 27% 0.06' Total Load D+0.75(L+S) TL Deflection 0.0566" 0.3073" L/999+ 3.12' Total Load D+S LL Deflection 0.0279" 0.2049" L/999+ 3.12' Total Load S Control: Positive Moment DOLs: Live=100% Snow=115% Roof=125% Wind=160% Manufacturer's installation guide MUST be consulted for multi-ply connection details and alternatives