10 -024 ICYNENE MD-C-200T Product Specs US ICYNENE MD-C-200™ - USA
Dec. 2, 2010 ICYNENE MD-C-200™ - US Product Specification Sheet
PRODUCT SPECIFICATION
1. PRODUCT NAME
Icynene MD-C-200™
ICYNENE MD-C-200™ is a
trademark for medium density,
closed cell polyurethane spray foam
insulation. ICYNENE MD-C-200™
is a 2.0 lb/ft3 density insulation and
air barrier material.
2. MANUFACTURER
ICYNENE MD-C-200™ is made on
site from liquid components
supplied by Icynene Inc. Installation
and on-site manufacturing are
supplied by independent Icynene
Licensed Dealers.
3. PRODUCT DESCRIPTION
ICYNENE MD-C-200™ is a 2.0
lb/ft3, closed cell insulation and air
barrier material. It insulates and air
seals at the same time. Convective
air movement inside cavities is
virtually eliminated, providing more
uniform temperatures throughout the
building.
The result is superior quality
construction, with higher comfort
levels and lower heating and cooling
costs. Energy savings vary
depending on building design,
location, etc.
ICYNENE MD-C-200™ expands to
fill cavities within the building
envelope. It doesn’t have to be cut
or fitted into the space.
ICYNENE MD-C-200™ is applied
by spraying the foam into an open
wall, crawl space, ceiling surface or
cathedral ceiling cavities. There it
expands in a matter of seconds to
provide a foam blanket of millions
of tiny closed cells, filling building
cavities and sealing cracks and
crevices in the process.
4. TECHNICAL DATA
(Based on Core Samples)
Thermal Performance
Aged Thermal Resistance,
1” aged 90 days @ 140 o F, R/in:
ASTM C518: R-6.7 (hr.ft2 -°F)/BTU
ICYNENE MD-C-200™ provides
improved performance over
traditional air permeable insulations
at equivalent R-values. ICYNENE
MD-C-200™ is not subject to loss
of R-value due to windy conditions,
settling, convection or air
infiltration; nor is it prone to
traditional moisture intrusion via
convective air flow or diffusion.
Air Permeance/Air Barrier /Air
Seal
Icynene MD-C-200™ fills any
shaped cavity, and adheres to most
construction materials, creating
assemblies with very low air-
permeance. Additional interior or
exterior air infiltration protection
within the building is subject to
applicable codes.
Air permeability of core foam:
ASTM E283 data
< 0.02 L/S-m2 @ 75 Pa for 1 in
thickness.
In all buildings insulated and air
sealed with Icynene MD-C-200™,
adequate mechanical ventilation/air
supply should be provided for
optimum IAQ (Indoor Air Quality).
See ASHRAE Guidelines.
Water Vapor Permeance
ICYNENE MD-C-200™ is a Class
II vapor retarder which reduces the
amount of moisture that can diffuse
through the insulation.
Water vapor transmission properties:
ASTM E96 (Desiccant Method):
0.9 Perms @ 1.5”
Water Absorption Properties
ICYNENE MD-C-200™ meets
FEMA criteria for resisting water
absorption.
Fungi Resistance
ASTM C1338
No Fungus growth
Burn Characteristics
ICYNENE MD-C-200™ is a
combustible product and is
therefore, consumed by flame, but
will not sustain flame upon removal
of the flame source. It leaves a
charcoal residue. It will not melt or
drip. It should be applied in
accordance with applicable building
codes.
Passed NFPA 285 and ASTM E119
60 minute rated wall assembly
testing:
ICYNENE MD-C-200™ is code
compliant for IBC construction
types I, II, III IV & V and IRC
construction.
Surface Burning Characteristics @
4” - ASTM E84*:
Flame Spread <25
Smoke Development <450
*Flame spread rating not intended to reflect hazards
under actual fire conditions.
NFPA 286:
MD-C-200™ can be applied in wall
and ceiling cavities with thicknesses
up to 11 1/4 in. It must be covered
with 1/2" of gypsum board or DC-
315 intumescent paint coating @ 22
wet mils.
Vented Attic:
MD-C-200™ can be applied in the
floor of the attic with thicknesses up
to 12 inches and it can be left
uncovered.
ICYNENE MD-C-200™ - USA
Dec. 2, 2010 ICYNENE MD-C-200™ - US Product Specification Sheet
Unvented Attic:
MD-C-200™ can be applied to the
underside of the roof deck in
thicknesses up to 12 inches and it
can be left bare.
MD-C-200™ can be applied on
walls in thicknesses up to 12 inches
and it can be left bare.
Environmental / Health / Safety
Icynene MD-C-200™ contains no
PBDE’s.
Not to be installed within (3") of
heat emitting devices, where the
temperature is in excess of 180°F, in
accordance with applicable codes.
5. INSTALLATIONS
ICYNENE MD-C-200™ is installed
by a network of independent
Icynene Licensed Dealers.
Formulations are available for all
climate zones and altitudes.
6. AVAILABILITY
Check regional Yellow Pages™ or
contact Icynene Inc. at 800-758-
7325 or visit our website at
www.Icynene.com.
7. WARRANTY
WHEN INSTALLED PROPERLY
IN ACCORDANCE WITH
INSTRUCTIONS, THE
COMPANY WARRANTS THAT
THE PROPERTIES OF THE
PRODUCT MEET PRODUCT
SPECIFICATIONS AS OUTLINED
IN THIS PRODUCT
SPECIFICATION SHEET. SAVE
AND EXCEPT ANY
EXCLUSIONS REFERENCED IN
THE WARRANTY.
8. TECHNICAL
Icynene Licensed Dealers and
Icynene Inc. provide support on both
technical and regulatory issues.
9. REGULATORY
ICYNENE MD-C-200™ has been
tested as per the requirements of the
International Code Council –
Evaluation Service’s AC 377
Acceptance Criteria.
For regulatory issues concerning
ICYNENE MD-C-200™, contact
Icynene at 800.758.7325.
10.9. RELATED REFERENCES
All physical properties were
determined through testing by
accredited third party agencies.
Icynene Inc. reserves the right to
change specifications in its effort of
continuous improvement. Please
confirm that technical data literature
is current.
11. PACKAGING AND
STORAGE
Packaging
Package - 55 US gallon, closed top
steel drums
Component ‘A’ –520 lb. net weight
per drum. Polyisocyanate MDI
Component ‘B’ – 480 lb. net weight
per drum
ICYNENE MD-C-200™ - Resin
Storage
ICYNENE MD-C-200™
(Component A) and (Component B)
ideally should be stored between 60
º F and 85 º F.
Component A should be protected
from freezing.
1212. INSTALLATION
SPECIFICATIONS
Refer to the ICYNENE MD-C-
200™ Technical Data Sheet.
Telephone: 905.363.4040
Toll Free: 800.758.7325
Facsimile: 905.363.0102
Website: www.Icynene.com
E-mail: inquiry@icynene.com