Loading...
10 -024 ICYNENE MD-C-200T Product Specs US ICYNENE MD-C-200™ - USA Dec. 2, 2010 ICYNENE MD-C-200™ - US Product Specification Sheet PRODUCT SPECIFICATION 1. PRODUCT NAME Icynene MD-C-200™ ICYNENE MD-C-200™ is a trademark for medium density, closed cell polyurethane spray foam insulation. ICYNENE MD-C-200™ is a 2.0 lb/ft3 density insulation and air barrier material. 2. MANUFACTURER ICYNENE MD-C-200™ is made on site from liquid components supplied by Icynene Inc. Installation and on-site manufacturing are supplied by independent Icynene Licensed Dealers. 3. PRODUCT DESCRIPTION ICYNENE MD-C-200™ is a 2.0 lb/ft3, closed cell insulation and air barrier material. It insulates and air seals at the same time. Convective air movement inside cavities is virtually eliminated, providing more uniform temperatures throughout the building. The result is superior quality construction, with higher comfort levels and lower heating and cooling costs. Energy savings vary depending on building design, location, etc. ICYNENE MD-C-200™ expands to fill cavities within the building envelope. It doesn’t have to be cut or fitted into the space. ICYNENE MD-C-200™ is applied by spraying the foam into an open wall, crawl space, ceiling surface or cathedral ceiling cavities. There it expands in a matter of seconds to provide a foam blanket of millions of tiny closed cells, filling building cavities and sealing cracks and crevices in the process. 4. TECHNICAL DATA (Based on Core Samples) Thermal Performance Aged Thermal Resistance, 1” aged 90 days @ 140 o F, R/in: ASTM C518: R-6.7 (hr.ft2 -°F)/BTU ICYNENE MD-C-200™ provides improved performance over traditional air permeable insulations at equivalent R-values. ICYNENE MD-C-200™ is not subject to loss of R-value due to windy conditions, settling, convection or air infiltration; nor is it prone to traditional moisture intrusion via convective air flow or diffusion. Air Permeance/Air Barrier /Air Seal Icynene MD-C-200™ fills any shaped cavity, and adheres to most construction materials, creating assemblies with very low air- permeance. Additional interior or exterior air infiltration protection within the building is subject to applicable codes. Air permeability of core foam: ASTM E283 data < 0.02 L/S-m2 @ 75 Pa for 1 in thickness. In all buildings insulated and air sealed with Icynene MD-C-200™, adequate mechanical ventilation/air supply should be provided for optimum IAQ (Indoor Air Quality). See ASHRAE Guidelines. Water Vapor Permeance ICYNENE MD-C-200™ is a Class II vapor retarder which reduces the amount of moisture that can diffuse through the insulation. Water vapor transmission properties: ASTM E96 (Desiccant Method): 0.9 Perms @ 1.5” Water Absorption Properties ICYNENE MD-C-200™ meets FEMA criteria for resisting water absorption. Fungi Resistance ASTM C1338 No Fungus growth Burn Characteristics ICYNENE MD-C-200™ is a combustible product and is therefore, consumed by flame, but will not sustain flame upon removal of the flame source. It leaves a charcoal residue. It will not melt or drip. It should be applied in accordance with applicable building codes. Passed NFPA 285 and ASTM E119 60 minute rated wall assembly testing: ICYNENE MD-C-200™ is code compliant for IBC construction types I, II, III IV & V and IRC construction. Surface Burning Characteristics @ 4” - ASTM E84*: Flame Spread <25 Smoke Development <450 *Flame spread rating not intended to reflect hazards under actual fire conditions. NFPA 286: MD-C-200™ can be applied in wall and ceiling cavities with thicknesses up to 11 1/4 in. It must be covered with 1/2" of gypsum board or DC- 315 intumescent paint coating @ 22 wet mils. Vented Attic: MD-C-200™ can be applied in the floor of the attic with thicknesses up to 12 inches and it can be left uncovered. ICYNENE MD-C-200™ - USA Dec. 2, 2010 ICYNENE MD-C-200™ - US Product Specification Sheet Unvented Attic: MD-C-200™ can be applied to the underside of the roof deck in thicknesses up to 12 inches and it can be left bare. MD-C-200™ can be applied on walls in thicknesses up to 12 inches and it can be left bare. Environmental / Health / Safety Icynene MD-C-200™ contains no PBDE’s. Not to be installed within (3") of heat emitting devices, where the temperature is in excess of 180°F, in accordance with applicable codes. 5. INSTALLATIONS ICYNENE MD-C-200™ is installed by a network of independent Icynene Licensed Dealers. Formulations are available for all climate zones and altitudes. 6. AVAILABILITY Check regional Yellow Pages™ or contact Icynene Inc. at 800-758- 7325 or visit our website at www.Icynene.com. 7. WARRANTY WHEN INSTALLED PROPERLY IN ACCORDANCE WITH INSTRUCTIONS, THE COMPANY WARRANTS THAT THE PROPERTIES OF THE PRODUCT MEET PRODUCT SPECIFICATIONS AS OUTLINED IN THIS PRODUCT SPECIFICATION SHEET. SAVE AND EXCEPT ANY EXCLUSIONS REFERENCED IN THE WARRANTY. 8. TECHNICAL Icynene Licensed Dealers and Icynene Inc. provide support on both technical and regulatory issues. 9. REGULATORY ICYNENE MD-C-200™ has been tested as per the requirements of the International Code Council – Evaluation Service’s AC 377 Acceptance Criteria. For regulatory issues concerning ICYNENE MD-C-200™, contact Icynene at 800.758.7325. 10.9. RELATED REFERENCES All physical properties were determined through testing by accredited third party agencies. Icynene Inc. reserves the right to change specifications in its effort of continuous improvement. Please confirm that technical data literature is current. 11. PACKAGING AND STORAGE Packaging Package - 55 US gallon, closed top steel drums Component ‘A’ –520 lb. net weight per drum. Polyisocyanate MDI Component ‘B’ – 480 lb. net weight per drum ICYNENE MD-C-200™ - Resin Storage ICYNENE MD-C-200™ (Component A) and (Component B) ideally should be stored between 60 º F and 85 º F. Component A should be protected from freezing. 1212. INSTALLATION SPECIFICATIONS Refer to the ICYNENE MD-C- 200™ Technical Data Sheet. Telephone: 905.363.4040 Toll Free: 800.758.7325 Facsimile: 905.363.0102 Website: www.Icynene.com E-mail: inquiry@icynene.com