24A-103 415 PROSPECT STREET STRUCTURAL DRAWING-S5-GENERAL NOTES AND DETAILSJACOB SMITH ENGINEERING AND DESIGN 5NIELDS / DUFFY RESIDENCE 415 PROSPECT STREET NORTHAMPTON MA 01060 GENERAL STRUCTURAL NOTES:DESIGN LIVE LOADS: 2009 I.R.C. and Commonwealth of Massachusetts, 8th Edition Amendments* Live Load uniform floor:L.L. = 40 psf* SnowPg = 40 psf* Wind90 mph, exposure C, 3-Sec gustDESIGN CODES:* National Design Specifications (N.D.S.)* American Institute of Steel Construction (AISC)* American Concrete Institute (ACI)* Concrete Reinforcing Steel Institute (CRSI)FOUNDATION:* Foundation are designed without an engineer's soil investigation. Foundation design criteria was assumed for purposes of foundationdesign could be confirmed by a soils engineer, at owner's expense, prior to construction. (This procedure may require revisions tofoundation design, at additional expense to the owner, if soils engineer determines that such design criteria are inappropriate for thisbuilding site.)* Footings shall be placed on undisturbed natural soil or compacted fill tested and approved by soils engineer.* Maximum design soil pressure: 2500 psfCONCRETE AND REINFORCEMENT:* Concrete shall conform to with the current ACI-301 Standard Specifications of Structural Concrete.Minimum 28 day compressive strength (F'c) and design properties as followsFoundation elements:F'c = 3000 psi min.Water/Cement ratio = .53 maxSlump = 5" maxEntrained Air = 6% max* Deformed reinforcement: New billet steel, ASTM A615 grade 60.* Reinforcement shall be fabricated and placed per ACI Manual of Standard Practice (ACI-315). &RQFUHWHFRYHURYHUUHLQIRUFHPHQWò´IRUFRQFUHWHSODFHGDJDLQVWIRUPV´IRUFRQFUHWHSODFHGDJDLQVWHDUWK* Keep reinforcement clean and free of dirt, oil, and scale. Oil forms prior to placing reinforcement.* Do not use Calcium Chloride in any add mixtures with reinforced concrete.* Appearance of finished concrete shall be approved by the Architect.WOOD FRAMING:* Dimension lumber is designed and shall be supplied using Jacob Smith Engineering and Design values design criteria.* General Framing: Spruce Pine Fir #1 and better (Maximum Moisture Content 19%) U.N.O.Plates:Sill plates: Pressure Treated Timber Strand LSL by Trus Joist or Pressure treated Doug Fir or Southern Pine #1 or better:Top and Bottom plates: Spruce Pine Fir #1 and better.1RWH³3UHVVXUH7UHDWHG/XPEHU´VKDOOEHIUDPLQJPDWHULDORIWKHVSHFLILHGVSHFLHVZKLFKKDVEHHQSUHVVXUHWUHDWHGZLWKGHFD\DQGinsect resistant solution, meeting all current standards for wood in contact with concrete or earth.Sill plates in contact with masonry or concrete foundations, footings or slabs may be treated Timber Strand LSL (zinc boratetreatment). Sodium borate treatment may also be acceptable for sill plate applications when protected from weather.Acceptable treatment mediums for wood in contact with earth or in exterior applications include ACQ-C and ACQ-D (AlkalineCopper Quaternary) and copper azole (CBA-A and CBA-B). DO NOT USE WOODS WHICH HAVE BEEN TREATED WITHAMMONIA BASED CARRIERS. All connectors shall meet the recommendations of the pressure treated wood manufactures, butshall be not less than Hot Dipped Galvanized meeting requirements of ASTM A653, such as Simpson ZMAX. (G185). All screws,nails and bolts shall match hangers and other connectors, and shall meet ASTM A123 for individual connectors, and ASTM A153 forfasteners.For durability, it is our recommendation that connectors used in exposed conditions with treated limber be stainless steel.Do not mix galvanized and stainless products.Do not allow aluminum to contact treated wood.* Laminated Veneer Lumber (L.V.L.): Fb min = 3000 psi, E min = 2.0 x10^6 psi* Studs: 2x6 Spruce Pine Fir No. 1/ No. 2 Grade.* Timber elements: Doug Fir #1 grade and better. (Maximum Moisture Content 19%)* Roof Sheathing: minimum 716" thick, DOC-PS1 CDX plywood APA rated 24/16 nailed with 8d common nails at 6" on center at allpanel edges and 12" on center at all panel fields.* Wall sheathing: 716" thick DOC-PS1 CDX plywood APA 2416 , nail with 8d common nails at 6" on center at all panel edges and 12" oncenter at all panel fields.* Floor sheathing: 2332" thick DOC-PS1, Tongue and Groove, APA rated 4824, nail with 10d common nails at 6" o.c. at all panel edges and12" o.c. at all panel fields.* Nailing per shall comply with IBC Table 2304.9.1 except where more or larger nailing shown on drawings.* All roof rafters, joists, beams shall be anchored to supports with metal framing anchors.* Provide continuous wall studs each side of wall openings equal to one half or greater of number of studs interrupted by openings.* All wall studs shall be continuous from floor to floor or from floor to roof.* Cross bridge all dimensional lumber roof and floor joists at midspan and provide solid blocking or rim joists at all joist supports andjoist ends.* Solid blocking between trusses at bearings.* Metal connectors: Simpson Strong Ties unless otherwise noted, install with number and type of nails to achieve maximum ratedcapacity. Note that heavy duty and skewed hangers may require special order.* All beams shall be braced against rotation at points of bearing.* Unless otherwise indicated, install two lengths of solid blocking x joist depth x 12 inches long in floor framing under column loads.Columns must have a continuous load path to foundation.* Lead holes for lag bolts shall be 60% to 70% of lag shank diameter in compliance with AITC criteria.STRUCTURAL STEEL:* All structural steel work shall conform with the current AISC construction manual and AWS structural welding code D1.1* Angles, channels, plate, and miscellaneous: ASTM A36.* Wide Flange Beams: ASTM A992* Threaded rod anchors: ASTM F1554 grade 36* Pipe Columns: ASTM A53, Grade "B".* Bolts shall be of a length that will fully engage the nuts. Bolt heads and nuts shall bear evenly against the metal.* All columns base plates set on concrete shall have leveling nuts and be packed solid to engage the entire base plate with 5000 psinon-shrink, non-metalic grout. Conform with ASTM C1107* Epoxy adhesive shall be "HILTI HIT HY-200"STRUCTURAL ERECTION AND BRACING REQUIREMENTS.* The structural drawings illustrate the completed structure with all elements in their final positions, properly supported and braced.The contractor, in the proper sequence, shall provide proper shoring and bracing as may be required to achieve the final completedstructure.* Observations of foundation reinforcing or steel framing required by the owner, lender, building department or any other party will beaccomplished by the engineer at the owner's expense. At least 24 hours advance notice is requested.* Fabricator and / or supplier of structural steel, and roof trusses, shall submit shop and erection drawings for architecturaland engineering review. Submit two prints for each drawing. Allow ten working days for review. No materials shall befabricated until shop drawings are approved.BUILDING SECTION1. See General Notes on this sheet.2. Coordinate all dimensions, elevations and openings with Architectural drawings.1S5SCALE: 12" = 1'-0"