38C-020 CF-A-110F
SEMERGENCY W1
F
S EMERGENCYW1
1'-6" MIN 6'-0"5'-0"5'-0"36" X 80"36" X 80"1'-9"1'-9"
FLOORING TO BE
FLUSH. THRESHOLD
NOT TO EXCEED 1/2"
IN HEIGHT, TYP.
FLOORING TO BE
FLUSH. THRESHOLD
NOT TO EXCEED 1/2"
IN HEIGHT, TYP.
ACOUSTIC CEILING.
7'-6" MIN HEIGHT.
ENLARGED TOILET/SHOWER ROOMS
SCALE: 1/2" = 1'-0" @ 24"X36"1
Architects
196 Pleasant Street, Suite 202
Northampton,
MA 01060
413-585-0641
http://www.tdouglasarchitects.com
REGISTERED ARCHITECT,
COMMONWEALTH OF
MASSACHUSETTS
This drawing is not intended nor shall it be
used for construction purposes unless the
Signed professional seal of a registered
architect employed by Thomas Douglas
Architects is affixed in the space below. The
Architect shall be deemed the author of these
documents and shall retain all common law,
statutory and other reserved rights, including
the copyright.
THOMAS DOUGLAS
Rev Date Description
Project Title
INTERIOR RENOVATIONS
project
PIONEER VALLEY
CROSS FIT
375 SOUTH STREET
NORTHAMPTON, MA
Issue Date:
Drawn By:
Checked By:
Project ID:
Drawing No.
Project North
1 4/05/2013 PERMIT SET
Sheet Title
Scale:
##/##/####
DB
DB/TD
130XX
AS NOTED
ENLARGED PLANS &
INTERIOR ELEVATIONS
A-110
INTERIOR ELEVATIONS OF TOILET ROOM
Scale: 1/2" = 1'-0"4
GWB
8'-0"6"3'-0"3'-6"2'-0"1'-5"1'-6"
TOILET PAPER
DISPENSER, TYP
A
GRAB
BARS.PROVIDE
WD BLOCKING
AS REQUIRED.
ACOUSTIC TILED
CEILING
COVER PIPES WITH
MOLDED VINYL
MATERIAL
WALL MIRROR
2'-10"GWB
CPAPER TOWELS 8'-0"COVER PIPES WITH
MOLDED VINYL
MATERIAL
CENTERLINE OF OUTLETS
AND SWITCHES 44" A.F.F
WALL MOUNTED SINK
D
3'-6"3'-0"2'-0"3'-0"
1'-0"GRAB BARS.
PROVIDE WD
BLOCKING AS
REQUIRED.
GWB
TOILET ROLL
HOLDER
7'-4 1/2"
WALL MOUNTED SOAP DISPENCERS,
WASTEBASKETS, AND "EMPLOYEES
MUST WASH HANDS" SIGNAGE
REQUIRED IN EACH TOILET ROOM.
TOILET ROOMS TO HAVE NEW
FLOORING TBD, PAINTED GWB
WALLS, AND ACOUSTIC TILE
CEILINGS.
D
INSTANT HOT WATER MOUNTED
ABOVE ACOUTIC CEILING.
F
S
FS
EMERGENCY EMERGENCYS S
F
EMERGENCYF S
EMERGENCY
W1W1C1 C1
C1 C1
SMOKE
HS
HS
EMERGENCY
EXIT
EMERGENCY
SMOKE
EMERGENCY HS
MEN'S
HC RESTROOM
MEN'S HC
SHOWER
SELF CLOSING HARDWARE
ON TOILET & SHOWER RM
DOORS, TYP
FLOORING TO BE
FLUSH. THRESHOLD
NOT TO EXCEED 1/2"
IN HEIGHT, TYP.
DROPPED CEILING, 2X2
ACOUSTICAL TILE, TYP.
ACCESSIBLE, ROLL-INN
SHOWER STALL. SEE
SPEC SHEET.9'-11"FLOORING TBD.
1'-8 3/4"
INFILL EXISTING
OPENING W BLOCK
TO MATCH
SURROUNDING.
WOMEN'S HC
SHOWER
GRAB BARS.
BLOCKING AS
REQUIRED.36" X 80"36" X 80"36" X 80"36" X 80"NEW OPENING IN
BLOCK WALL.
ENGINEER TO
DETERMINE SIZE OF
STEEL HEADER. 36"
X 84" MIN.4'-0"5'-0"3'-0"5'-0"
14'-2 1/4"
1'-6"MIN 1'-6"MIN
36" X 36"
SEE SPEC
36" X 36"
SEE SPEC
12'-3 1/2"3'-0"7'-4 1/2"7'-4 1/2"
2'-0 1/2"
INSULATE EXTERIOR
WALLS, MIN R-19.
1'-8 3/4"1'-6"1'-6"3'-6"STOR
CENTER OPENING
]WOMEN'S
HC RESTROOM
7'-6"ENLARGED TOILET ROOMS
SCALE: 1/2" = 1'-0" @ 24"X36"2
RAMP UP
1" per 12"071'-11"7'-0"1'-0"4'-0"P EXIT
EMERGENCY
NOTE: RAMP AND HANDRAILS TO
COMPLY WITH 521 CMR 24
GUARD/ RAILING
PROVIDED BY
TENANT'S
EQUIPMENT.
ENLARGED INTERIOR RAMP
SCALE: 1/2" = 1'-0" @ 24"X36"3