Loading...
38C-020 CF-A-110F SEMERGENCY W1 F S EMERGENCYW1 1'-6" MIN 6'-0"5'-0"5'-0"36" X 80"36" X 80"1'-9"1'-9" FLOORING TO BE FLUSH. THRESHOLD NOT TO EXCEED 1/2" IN HEIGHT, TYP. FLOORING TO BE FLUSH. THRESHOLD NOT TO EXCEED 1/2" IN HEIGHT, TYP. ACOUSTIC CEILING. 7'-6" MIN HEIGHT. ENLARGED TOILET/SHOWER ROOMS SCALE: 1/2" = 1'-0" @ 24"X36"1 Architects 196 Pleasant Street, Suite 202 Northampton, MA 01060 413-585-0641 http://www.tdouglasarchitects.com REGISTERED ARCHITECT, COMMONWEALTH OF MASSACHUSETTS This drawing is not intended nor shall it be used for construction purposes unless the Signed professional seal of a registered architect employed by Thomas Douglas Architects is affixed in the space below. The Architect shall be deemed the author of these documents and shall retain all common law, statutory and other reserved rights, including the copyright. THOMAS DOUGLAS Rev Date Description Project Title INTERIOR RENOVATIONS project PIONEER VALLEY CROSS FIT 375 SOUTH STREET NORTHAMPTON, MA Issue Date: Drawn By: Checked By: Project ID: Drawing No. Project North 1 4/05/2013 PERMIT SET Sheet Title Scale: ##/##/#### DB DB/TD 130XX AS NOTED ENLARGED PLANS & INTERIOR ELEVATIONS A-110 INTERIOR ELEVATIONS OF TOILET ROOM Scale: 1/2" = 1'-0"4 GWB 8'-0"6"3'-0"3'-6"2'-0"1'-5"1'-6" TOILET PAPER DISPENSER, TYP A GRAB BARS.PROVIDE WD BLOCKING AS REQUIRED. ACOUSTIC TILED CEILING COVER PIPES WITH MOLDED VINYL MATERIAL WALL MIRROR 2'-10"GWB CPAPER TOWELS 8'-0"COVER PIPES WITH MOLDED VINYL MATERIAL CENTERLINE OF OUTLETS AND SWITCHES 44" A.F.F WALL MOUNTED SINK D 3'-6"3'-0"2'-0"3'-0" 1'-0"GRAB BARS. PROVIDE WD BLOCKING AS REQUIRED. GWB TOILET ROLL HOLDER 7'-4 1/2" WALL MOUNTED SOAP DISPENCERS, WASTEBASKETS, AND "EMPLOYEES MUST WASH HANDS" SIGNAGE REQUIRED IN EACH TOILET ROOM. TOILET ROOMS TO HAVE NEW FLOORING TBD, PAINTED GWB WALLS, AND ACOUSTIC TILE CEILINGS. D INSTANT HOT WATER MOUNTED ABOVE ACOUTIC CEILING. F S FS EMERGENCY EMERGENCYS S F EMERGENCYF S EMERGENCY W1W1C1 C1 C1 C1 SMOKE HS HS EMERGENCY EXIT EMERGENCY SMOKE EMERGENCY HS MEN'S HC RESTROOM MEN'S HC SHOWER SELF CLOSING HARDWARE ON TOILET & SHOWER RM DOORS, TYP FLOORING TO BE FLUSH. THRESHOLD NOT TO EXCEED 1/2" IN HEIGHT, TYP. DROPPED CEILING, 2X2 ACOUSTICAL TILE, TYP. ACCESSIBLE, ROLL-INN SHOWER STALL. SEE SPEC SHEET.9'-11"FLOORING TBD. 1'-8 3/4" INFILL EXISTING OPENING W BLOCK TO MATCH SURROUNDING. WOMEN'S HC SHOWER GRAB BARS. BLOCKING AS REQUIRED.36" X 80"36" X 80"36" X 80"36" X 80"NEW OPENING IN BLOCK WALL. ENGINEER TO DETERMINE SIZE OF STEEL HEADER. 36" X 84" MIN.4'-0"5'-0"3'-0"5'-0" 14'-2 1/4" 1'-6"MIN 1'-6"MIN 36" X 36" SEE SPEC 36" X 36" SEE SPEC 12'-3 1/2"3'-0"7'-4 1/2"7'-4 1/2" 2'-0 1/2" INSULATE EXTERIOR WALLS, MIN R-19. 1'-8 3/4"1'-6"1'-6"3'-6"STOR CENTER OPENING ]WOMEN'S HC RESTROOM 7'-6"ENLARGED TOILET ROOMS SCALE: 1/2" = 1'-0" @ 24"X36"2 RAMP UP 1" per 12"071'-11"7'-0"1'-0"4'-0"P EXIT EMERGENCY NOTE: RAMP AND HANDRAILS TO COMPLY WITH 521 CMR 24 GUARD/ RAILING PROVIDED BY TENANT'S EQUIPMENT. ENLARGED INTERIOR RAMP SCALE: 1/2" = 1'-0" @ 24"X36"3