Loading...
36 -075 HOENER DECK A-18-25-16FOR REVIEWmlCONSTRUCTASSOCIATES, INC.36 SERVICE CENTERNORTHAMPTON, MA 01060tel: 584-1224 fax: 584-7504EXISTING ANDPROPOSED PLANSA-1SCALE AS NOTEDPROPOSED DECK PLAN1/4" = 1'-0"1NEW WOOD DECKPROPOSED DECK FRAMING PLAN1/4" = 1'-0"2BEDROOMKITCHENCH.DN1RDN4RPRESSURE TREATED WOOD DECKINGREMOVE EXISTINGSTAIR AND LANDINGPRE-MANUFACTURED HANDRAIL POST AND BALUSTER SYSTEM, TYPICAL2 X 6 PRESSURE TREATEDTREADS AT NEW STAIR TOGRADECH.12'-0"16'-0"23'-0"8'-0"8'-0"± 6"± 6"4'-0"5'-6"5'-6"5'-6"5'-6"EXISTING HOUSE2 X 8 PRESSURE TREATED WOOD JOISTS, 16" ON CENTER(5) POURED CONCRETE FOOTING PIERS,WITH FLARED BOTTOMS, 4'-0" BELOWGRADE, MINIMUM2 X 8 PRESSURE TREATED LEDGER,WITH (2) SDS, 24" ON CENTERJOIST HANGER, TYPICAL2 X 8 PRESSURE TREATED BAND JOIST, TYPICAL(2) 2 X 10 PRESSURE TREATED GRADE BEAM, WITH PT PLYWOOD FLITCH (5) 2 X 12 PRESSURE-TREATED STAIR STRINGERS 33RENOVATIONS FOR:HOENERRESIDENCE 363 WESTHAMPTON ROADNORTHAMPTON, MA 01060BABA123CCDrawn ByDate Issue 1233DECK SECTION 3/4" = 1'-0"2 X 8, 16" O.C. PRESSURE-TREATED JOISTS.LEDGERJOIST HANGER6"EXISTING DOORSTEP DOWNFLASHING ATLENGTH OFLEDGER8" POURED CONCRETE PIERWITH FLARED BOTTOM1/2" X 10" ANCHOR BOLTSIMPSON CONNECTOR4 X 4 PT POST2 X 8, 16" O.C. PRESSURE-TREATED BAND JOIST5/4 X 6 PRESSURE-TREATED DECKING3'-0"SIMPSON DTT2Z CONNECTORAT EACH POST4 X 4 PT POST WITH COVERAND CAP, BALUSTRADESYSTEMAPPROX. 2'-5"4'-0" MINIMUM(2) SDS @ 24"ON CENTER