15B-050 NDZ spec (1)Specification Catalog 5 Series 500R11 Indoor Split Geothermal Heat Pump 2-6 ton (single speed) 2-6 ton (dual capacity) 5 SERIES 500R11 SPECIFICATION CATALOG Table of Contents The 5 Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4 Model Nomenclature . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5 AHRI Data. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-7 5 Series Indoor Split Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8 5 Series Design Features. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9-10 The AuroraTM Control System. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11-16 Operation Logic Data Table . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17 Water Quality . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18 Dimensional Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19 Physical Data. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .20 Electrical Data. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .20 Model Nomenclature - Air Handler . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21 Air Handler Compatibility . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21 Physical Data - Envision Air Handler. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .22 Line Set Sizes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .22 Model Nomenclature - Coil. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .23 Refrigerant Coil Compatibility . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .23 Reference Calculations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .24 Legend and Notes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .24 Operating Limits. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .25 Operating Parameters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .25-26 Pressure Drop . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .27 Performance Data. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .28-44 Wiring Schematics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45-46 Engineering Guide Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .47-48 Revision Guide. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .49 4 5 SERIES 500R11 SPECIFICATION CATALOG 5 Series indoor splits are designed for indoor installations, and are connected to an indoor air handler via refrigerant lines and control wiring. NSZ and NDZ units utilize the ozone-safe R-410A refrigerant to meet the most stringent EPA requirements now and for many years to come. Easily accessible controls and connections for refrigerant piping and water piping make this unit simple to install in a wide variety of applications. Heavy gauge metal cabinets are coated with durable poly paint for long lasting beauty and protection. No matter what the installation, the 5 Series indoor split will provide exceptional performance and comfort for many years. And because there is no outdoor blower like ordinary air conditioners or heat pumps, the NSZ and NDZ is exceptionally quiet. A new sophisticated AuroraTM Control system is modular and designed to grow with the application. The Aurora ‘Base’ Control (ABC) features a microprocessor control to sequence all components during operation for optimum performance. Plus, the ABC provides easy-to-use troubleshooting features with fault lights, on-board diagnostics, and a hand held Aurora Interface Diagnostic (AID) Tool. 5 Series products are performance-certifi ed to AHRI/ISO 13256-1 standards, ETL listed, ENERGY STAR® qualifi ed, and tested in an ISO 17025 accredited testing lab. As a leader in the industry, WaterFurnace is dedicated to innovation, quality, and customer satisfaction. In fact, every unit built is exposed to a wide range of quality control procedures throughout the assembly process and is then subjected to a rigorous battery of computerized run tests to certify that it meets or exceeds performance standards for effi ciency and safety, and will perform fl awlessly at startup. As further affi rmation of our quality standards, each unit carries our exclusive Quality Assurance emblem, signed by the fi nal test technician. WaterFurnace International’s corporate headquarters ISO 9001:2008 and manufacturing facility is located in Fort Wayne, IN. A scenic three-acre pond located in front of the building serves as our geothermal heating and cooling source to comfort-condition our 110,000 square feet of manufacturing and offi ce space. As a pioneer, and now a leader in the indus- try, the team of WaterFurnace engineers, customer support staff, and skilled assembly technicians is dedicated to providing the fi nest comfort systems available. All 5 Series products are safety listed under UL1995 thru ETL and performance listed with AHRI in accordance with standard 13256-1. The 5 Series is also ENERGY STAR rated. 500R11 Geothermal Heat Pump 5 5 SERIES 500R11 SPECIFICATION CATALOG Model Nomenclature N D Z 049 *1 1 0 C N N 0 A 1 2 3 4-6 7 8 9 10 11 12 13 14 15 Model N – 5 Series Stage D – Dual Capacity S – Single Capacity Cabinet Configuration Z – Indoor Split Unit Capacity 022, 026, 030, 036, 038, 042, 048, 049, 060, 064, 070, 072 Vintage * - Factory Use Only Voltage 1 – 208-230/60/1 Hot Water Generation 0 – None 1 – Hot Water Generation with Factory Installed Pump IntelliStart Option N – None A - IntelliStart Controls A – AuroraTM Base Control (ABC) Future Options 0 – None Future Options N – None Future Options N – None Water Coax Option C – Copper N – CuproNickel Future Option 0 - None Rev.: 06 June 2013D A 16 6 5 SERIES 500R11 SPECIFICATION CATALOG AHRI Data Cooling capacities based upon 80.6°F DB, 66.2°F WB entering air temperature Heating capacities based upon 68°F DB, 59°F WB entering air temperature All ratings based upon operation at the lower voltage of dual voltage rated models. Refer to the air handler compatibility table for matching air handler. AHRI/ASHRAE/ISO 13256-1 English (IP) Units Model Capacity Modulation Flow Rate Water Loop Heat Pump Ground Water Heat Pump Ground Loop Heat Pump Cooling Brine EWT 86°F Heating Brine EWT 68°F Cooling EWT 59°F Heating EWT 50°F Cooling Brine Full Load 77°F Part Load 68°F Heating Brine Full Load 32°F Part Load 41°F gpm cfm Capacity Btu/h EER Btu/h/W Capacity Btu/h COP Capacity Btu/h EER Btu/h/W Capacity Btu/h COP Capacity Btu/h EER Btu/h/W Capacity Btu/h COP 026 Full 8 900 25,000 14.6 30,500 5.1 27,800 21.8 25,000 4.6 26,200 17.0 19,500 3.9 Part 7 700 18,500 16.6 22,000 5.6 21,300 28.4 17,700 4.8 21,000 24.5 16,200 4.4 038 Full 9 1200 34,000 14.6 40,100 5.0 34,300 20.4 33,100 4.5 35,000 17.1 25,700 3.8 Part 8 800 25,000 16.6 30,000 5.3 25,200 27.0 24,400 4.4 27,000 25.3 22,100 4.2 049 Full 12 1500 45,900 14.0 56,800 4.7 50,500 20.2 46,700 4.4 47,700 16.1 37,000 3.8 Part 11 1300 35,000 16.2 43,000 5.5 37,300 25.8 33,000 4.7 38,000 22.9 30,500 4.3 064 Full 16 1800 56,300 14.7 67,100 4.6 63,800 19.2 55,800 4.3 59,100 15.5 43,200 3.6 Part 14 1500 42,900 15.7 49,500 5.1 50,000 24.9 41,000 4.3 47,900 22.2 36,800 3.9 072 Full 18 1800 60,400 13.3 80,600 4.6 67,900 17.8 63,100 3.9 62,700 15.0 50,300 3.4 Part 16 1600 49,700 14.6 60,200 4.8 57,200 22.8 48,400 4.0 53,800 20.0 42,800 3.8 022 Single 8 800 19,700 16.3 23,500 5.3 23,300 27.9 18,900 4.5 21,800 19.5 14,000 3.7 030 Single 8 1000 25,800 17.3 32,000 5.5 28,500 24.9 25,300 4.9 26,800 19.8 19,700 4.0 036 Single 9 1200 31,400 17.6 37,600 5.5 33,900 27.0 30,000 4.7 31,900 19.8 24,000 4.0 042 Single 10 1400 39,000 17.3 41,400 5.3 42,900 25.3 33,000 4.5 39,900 19.9 25,300 3.7 048 Single 12 1500 44,200 15.5 55,400 5.2 48,900 23.8 45,100 4.5 46,200 18.1 35,300 3.8 060 Single 15 1800 54,600 14.4 66,300 4.6 62,300 21.1 52,900 4.1 57,000 17.1 44,500 3.6 070 Single 18 1800 60,200 13.2 76,000 4.2 68,500 19.2 63,000 3.7 63,200 15.1 50,800 3.3 1/3/12 Energy Star Compliance Table Model Tier 3 Ground Water Ground Loop 026 Yes Yes 038 Yes Yes 049 Yes Yes 064 Yes Yes 072 No Yes 022 Yes Yes 030 Yes Yes 036 Yes Yes 042 Yes Yes 048 Yes Yes 060 Yes Yes 070 No No NOTE: This product meets Energy Star requirements when purchased with a minimum 5 year warranty and appropriate coil components are used. Ask your contractor for details. 1/3/12 Energy Star Rating Criteria In order for water-source heat pumps to be Energy Star rated they must meet or exceed the minimum efficiency requirements listed below. Tier 3: 1/1/2012 – No Effective End Date Published EER COP Closed loop water-to-air 17.1 3.6 Open loop water-to-air 21.1 4.1 Closed loop water-to-water 16.1 3.1 Open loop water-to-water 20.1 3.5 7 5 SERIES 500R11 SPECIFICATION CATALOG The performance standard AHRI/ASHRAE/ISO 13256-1 became effective January 1, 2000 and replaces ARI Standards 320, 325, and 330. This new standard has three major categories: Water Loop (comparable to ARI 320), Ground Water (ARI 325), and Ground Loop (ARI 330). Although these standards are similar there are some differences: Unit of Measure: The Cooling COP The cooling efficiency is measured in EER (US version measured in Btu/h per Watt. The Metric version is measured in a cooling COP (Watt per Watt) similar to the traditional COP measurement. Water Conditions Differences Entering water temperatures have changed to reflect the centigrade temperature scale. For instance the water loop heating test is performed with 68°F (20°C) water rounded down from the old 70°F (21.1°C). Air Conditions Differences Entering air temperatures have also changed (rounded down) to reflect the centigrade temperature scale. For instance the cooling tests are performed with 80.6°F (27°C) dry bulb and 66.2°F (19°C) wet bulb entering air instead of the traditional 80°F (26.7°C) DB and 67°F (19.4°C) WB entering air temperatures. 80.6/66.2 data may be converted to 80/67 using the entering air correction table. This represents a significantly lower relative humidity than the old 80/67 of 50% and will result in lower latent capacities. Pump Power Correction Calculation Within each model, only one water flow rate is specified for all three groups and pumping Watts are calculated using the following formula. This additional power is added onto the existing power consumption. • Pump power correction = (gpm x 0.0631) x (Press Drop x 2990) / 300 Where ‘gpm’ is waterflow in gpm and ‘Press Drop’ is the pressure drop through the unit heat exchanger at rated water flow in feet of head. Blower Power Correction Calculation Blower power is corrected to zero external static pressure using the following equation. The nominal airflow is rated at a specific external static pressure. This effectively reduces the power consumption of the unit and increases cooling capacity but decreases heating capacity. These Watts are significant enough in most cases to increase EER and COPs fairly dramatically over ARI 320, 325, and 330 ratings. • Blower Power Correction = (cfm x 0.472) x (esp x 249) / 300 Where ‘cfm’ is airflow in cfm and ‘esp’ is the external static pressure at rated airflow in inches of water gauge. ISO Capacity and Efficiency Calculations The following equations illustrate cooling calculations: • ISO Cooling Capacity = Cooling Capacity (Btu/h) + (Blower Power Correction (Watts) x 3.412) • ISO EER Efficiency (W/W) = ISO Cooling Capacity (Btu/h) x 3.412 / [Power Input (Watts) - Blower Power Correction (Watts) + Pump Power Correction (Watt)] The following equations illustrate heating calculations: • ISO Heating Capacity = Heating Capacity (Btu/h) - (Blower Power Correction (Watts) x 3.412) • ISO COP Efficiency (W/W) = ISO Heating Capacity (Btu/h) x 3.412 / [Power Input (Watts) - Blower Power Correction (Watts) + Pump Power Correction (Watt)] Comparison of Test Conditions Conversions: Airflow (lps) = cfm x 0.472; WaterFlow (lps) = GPM x 0.0631; ESP (Pascals) = ESP (in wg) x 249; Press Drop (Pascals) = Press Drop (ft hd) x 2990 ARI 320 ISO/AHRI 13256-1 WLHP ARI 325 ISO/AHRI 13256-1 GWHP ARI 330 ISO/AHRI 13256-1 GLHP Cooling Entering Air - DB/WB °F 80/67 80.6/66.2 80/67 80.6/66.2 80/67 80.6/66.2 Entering Water - °F 85 86 50/70 59 77 77 Fluid Flow Rate * ** ** ** ** ** Heating Entering Air - DB/WB °F 70 68 70 68 70 68 Entering Water - °F 70 68 50/70 50 32 32 Fluid Flow Rate * ** ** ** ** ** Note *: Flow rate is set by 10°F rise in standard cooling test Note **: Flow rate is specified by the manufacturer Part load entering water conditions not shown. WLHP = Water Loop Heat Pump; GWHP = Ground Water Heat Pump; GLHP = Ground Loop Heat Pump AHRI Data cont. 8 5 SERIES 500R11 SPECIFICATION CATALOG 5 Series Indoor Split Features COMPRESSOR: Copeland Scroll™ (022-070 single speed) and Copeland Scroll UltraTech™ (dual capacity 026-072) represent the latest technology DOUBLE ISOLATED COMPRESSOR: Double isolated compressor mounting to reduce noise and vibration AURORA CONTROLS & AID TOOL: Aurora ‘Base’ Control and Aurora AID Tool COAXIAL HEAT EXCHANGER: Standard large high efficiency copper (optional cupronickel) coax with our exclusive void-free and robotically applied ThermaShield insulation coating BALANCED PORT EXPANSION VALVE: Balanced port expansion valve for steady superheat control and reliable efficiency and operation at any condition (not shown) DISCHARGE MUFFLER: Helps quiet compressor gas pulsations SWIVEL LOOP CONNECTIONS: Leak free swivel water connections provide a hand tight gasket connection that easily handles the temperature extremes of geothermal earth loops INTELLISTART®: Optional single phase soft starter INSULATION: Cleanable foil lined insulation to prevent mold growth; corrosion resistant composite drain pan CABINET FINISH: Heavy gauge galvanized sheet metal cabinet has 1,000 hr. salt spray rated gray powder coat paint for long life ACCESS PANELS: Lift out front bottom access panel, lift out panels for easier removal and servicing AID TOOL PORT: AID Tool port provides quick AID Tool connection ACCUMULATOR: Safeguards the compressor against liquid refrigerant flowback SERVICE VALVES: Brass service valves with service port for easy installation, charging, and service RECESSED LINE SET: Line set stubs are recessed to protect service valves during shipment DECORATIVE COVER: Matching painted cover for line set stubs after brazing enhances cabinet appearance LIQUID LINE FILTER DRIER: Removes moisture and contaminates from the refrigerant stream ensuring trouble-free operation (not shown) 9 5 SERIES 500R11 SPECIFICATION CATALOG What’s New? • Latest technology compressors - Copeland K5 Scrolls™ in single speed units (sizes 022, 030, 036, 042, 048, 060, 070) - Copeland UltraTech™ K5 Compressors in dual capacity units (sizes 026, 038, 049, 064, 072) • AuroraTM Communicating Control Features - Traditional Safety Sensors: HP, LP, condensate overflow, freeze detection loop - Communicating Modular Design: Communicating modular design for flexibility and expandability - Electric Heat Powered Blower and Controls: Prevents the compressor from tripping out and disabling heat in the house - Internet Ready: With optional Aurora WebLink (AWL) device and Tendril Web Portal (Future Availability) • Advanced Service Features - Aurora Controls with the AID Tool provide advanced service diagnostics. With this device setup and configurations as well as real-time sensors fault and lockout history can be monitored and much more. - Aurora can be internet capable simply by adding the Aurora WebLink (AWL). This device will connect your Aurora system to web for remote monitoring and control. It also comes standard with an SD drive for storing operating and performance data. Providing ‘black box’ capability (Future Availability) Application Flexibility • Approved for indoor installation. • Safe, efficient operation in a wide range of liquid temperatures (20° F to 120° F) and flow rates (as low as 1.5 GPM/ton in open loop applications when EWT >50°F) • Easily accessible loop pump wiring Operating Efficiencies • AHRI 13256-1 rating for heating COPs, cooling EERs and low water flow requirements • High-stability expansion valve delivers optimum refrigerant flow over a wide range of conditions • Efficient Copeland scroll compressors provide superior comfort levels • Accumulator is on all models for added compressor reliability • Oversized coaxial tube water-to-refrigerant heat exchanger operates at low liquid pressure drops • Convoluted cupronickel water tube functions efficiently at low flow rates, and provides freeze-damage resistance • Utilizes the ozone-friendly R-410A refrigerant which produces higher efficiencies and warmer discharge air temperatures Service Advantages • Hinged/removable control box for added serviceability • Removable panels: three for the compressor compartment provide quick access to all internal components • Easily accessible thermal expansion valve • Brass, swivel-type water connections for quick connection union, and elimination of wrenches and sealants during installation; sweat type connections are on the hot water generator • Designed for front access in tight applications • LED fault and status lights on the Aurora board with memory for easy diagnostics • Aurora AID Tool provides enhanced service information via communication directly with the Aurora control including sensor inputs, fault history, and much more • Detachable thermostat connection strip for wiring convenience • Hot water pump shut-off switch for easy startup and service • Control box has quick-attach wiring plugs for easy removal • High- and low-pressure service ports in refrigerant circuit Microprocessor Benefits • Communicating monochromatic or color digital auto- changeover thermostat with 3-stage heating/2-stage cooling holds precise temperature and provides varying blower speed control 5 Series Design Features 10 5 SERIES 500R11 SPECIFICATION CATALOG Options and Accessories • AID Tool: The Aurora Interface and Diagnostics (AID) Tool is a plug-in configuration and troubleshooting tool for the Aurora Control System • Aurora WebLink (AWL) (Future Availability): The Aurora Control System can be made internet capable simply by adding the Aurora WebLink (AWL) device. The AWL will connect your Aurora system to the web for remote monitoring and control. It also comes standard with an SD disc for storing operating and performance data providing true ‘black box’ capability for troubleshooting • Closed loop flow center and loop circulating kits. • Additional accessory relay • Bramec III, 6x6 modular mounting pad • IntelliStart compressor soft starter • NRAC encased and uncased coil assemblies Manufacturing Quality • All units are computer run-tested, with conditioned source water, in all modes to ensure efficiency and reliability • All refrigerant brazing is performed in a nitrogen atmosphere • All units are deep evacuated to less than 150 microns prior to refrigerant charging • All joints are helium leak-tested to ensure an annual leak rate of less than 1/4 ounce • All major components bar coded; eliminating possibility of mismatched parts built into unit • All assembly technicians thoroughly trained in proper quality procedures • All units have model number and serial number embedded in control for local or remote retrieval • WaterFurnace International, Inc. is an ISO 9001:2008 certified manufacturing facility • WaterFurnace International, Inc. engineering labs are ISO 17025 accredited 5 Series Design Features cont. 11 5 SERIES 500R11 SPECIFICATION CATALOG The Aurora™ Control System Aurora ‘Base’ Control The Aurora ‘Base’ Control (ABC) System is a complete residential and commercial comfort system that brings all aspects of the HVAC system into one cohesive module network. The ABC features microprocessor control and HP, LP, and freeze detection, over/under voltage faults, along with communicating thermostat capability for complete fault detection text at the thermostat. Aurora uses the Modbus communication protocol to communicate between modules. Each module contains the logic to control all features that are connected to the module. The Aurora ‘Base’ Control (ABC) has two Modbus channels. The first channel is configured as a master for connecting to devices such as a communicating thermostat, expansion board, or other slave devices. The second channel is configured as a slave for connecting the Aurora Interface Diagnostics Tool (AID Tool). Service Device Description Aurora ‘Base’ Aurora Interface and Diagnostics (AID) Tool Allows setup, monitoring and troubleshooting of any Aurora Control. NOTE: Although the ABC has basic compatibility with all Aurora, new product features may not be available on older AID Tools. To simplify the basic compatibility ensure the version of AID is at least the same or greater than the ABC software version. For Service (Ver. 1.xx or greater) Add On Thermostats and Zoning Description Aurora ‘Base’ TP32U03/04 - MonoChrome Traditional Y1, Y2 Thermostat Elite Stat with full English fault codes and alerts, traditional Y1, Y2 thermostat Optional TP32S01/02 - Traditional Y1, Y2 Thermostat Traditional Y1, Y2 thermostat Optional IntelliZone® Zoning Compatibility IntelliZone® is a non-communicating zoning system requiring Y1, Y2 signals and controls the ECM blower motor directly. Optional (ECM Preferred) 12 5 SERIES 500R11 SPECIFICATION CATALOG The Aurora Control System cont. Aurora ‘Base’ Control NOTE: Refer to the Aurora Base Control Application and Troubleshooting Guide and the Instruction Guide: Aurora Interface and Diagnostics (AID) Tool for additional information. Control Features Software ABC Standard Version 2.0 Single or Dual Capacity Compressors Either single or dual capacity compressors can be operated. Other Control Features • Random start at power up • Anti-short cycle protection • High and low pressure cutouts • Loss of charge • Water coil freeze detection • Over/under voltage protection • Load shed • Emergency shutdown • Hot gas reheat operation (where applicable) • Diagnostic LED • Test mode push button switch • Alarm output • Accessory output with N.O. and N.C. • Modbus communication (master) • Modbus communication (slave) Field Selectable Options via Hardware DIP Switch (SW1) – Test/Configuration Button (See SW1 Operation Table) Test Mode The control is placed in the test mode by holding the push button switch SW1 for 2 - 5 seconds. In test mode most of the control timings will be shortened by a factor of sixteen (16). LED3 (green) will flash at 1 second on and 1 second off. Additionally, when entering test mode LED1 (red) will flash the last lockout one time. Test mode will automatically time out after 30 minutes. Test mode can be exited by pressing and holding the SW1 button for 2 to 5 seconds or by cycling the power. NOTE: Test mode will automatically be exited after 30 minutes. Reset Configuration Mode The control is placed in reset configuration mode by holding the push button switch SW1 for 50 to 60 seconds. This will reset all configuration settings and the EEPROM back to the factory default settings. LED3 (green) will turn off when entering reset configuration mode. Once LED3 (green) turns off, release SW1 and the control will reset. DIP Switch (SW2) SW2-1 FP1 Selection – Low water coil temperature limit setting for freeze detection. On = 30°F; Off = 15°F. SW2-2 FP2 Selection – On = 30°F; Off = N/A SW2-3 RV – O/B - thermostat type. Heat pump thermostats with “O” output in cooling or “B” output in Heating can be selected. On = O; Off = B. SW2-4 Access Relay Operation (P2) and 2-5 Access Relay Operation SW2-4 SW2-5 Cycle with Blower ON ON Cycle with Compressor OFF OFF Water Valve Slow Opening ON OFF Cycle with Comm. T-stat Hum Cmd OFF ON Cycle with Blower - The accessory relay will cycle with the blower output. Cycle with Compressor - The accessory relay will cycle with the compressor output. Water Valve Slow Opening - The accessory relay will cycle and delay both the blower and compressor output for 90 seconds. SW2-6 CC Operation – selection of single or dual capacity compressor. On = Single Stage; Off = Dual Capacity SW2-7 Lockout and Alarm Outputs (P2) – selection of a continuous or pulsed output for both the LO and ALM Outputs. On = Continuous; Off = Pulsed SW2-8 Future Use Alarm Jumper Clip Selection From the factory, ALM is connected to 24 VAC via JW2. By cutting JW2, ALM becomes a dry contact connected to ALG. 13 5 SERIES 500R11 SPECIFICATION CATALOG The Aurora ‘Base’ Control System cont. Safety Features The following safety features are provided to protect the compressor, heat exchangers, wiring and other components from damage caused by operation outside of design conditions. Fuse – a 3 amp automotive type plug-in fuse provides protection against short circuit or overload conditions. Anti-Short Cycle Protection – 4 minute anti-short cycle protection for the compressor. Random Start – 5 to 80 second random start upon power up. Fault Retry – in the fault condition, the control will stage off the outputs and then “try again” to satisfy the thermostat Y input call. Once the thermostat input calls are satisfied, the control will continue on as if no fault occurred. If 3 consecutive faults occur without satisfying the thermostat Y input call, then the control will go to Lockout mode. Lockout – when locked out, the blower will operate continuously, and PSC blower motor output will remain on. The Alarm output (ALM) and Lockout output (L) will be turned on. The fault type identification display LED1 (Red) shall flash the fault code. To reset lockout conditions with SW2-8 On, thermostat inputs “Y1”, “Y2”, and “W” must be removed for at least 3 seconds. To reset lockout conditions with SW2-8 Off, thermostat inputs “Y1”, “Y2”, “W”, and “DH” must be removed for at least 3 seconds. Lockout may also be reset by turning power off for at least 30 seconds or by enabling the emergency shutdown input for at least 3 seconds. High Pressure – fault is recognized when the Normally Closed High Pressure Switch, P4-9/10 opens, no matter how momentarily. The High Pressure Switch is electrically in series with the Compressor Contactor and serves as a hard- wired limit switch if an overpressure condition should occur. Low Pressure - fault is recognized when the Normally Closed Low Pressure Switch, P4-7/8 is continuously open for 30 seconds. Closure of the LPS any time during the 30 second recognition time restarts the 30 second continuous open requirement. A continuously open LPS shall not be recognized during the 2 minute startup bypass time. Loss of Charge – fault is recognized when the Normally Closed Low Pressure Switch, P4-7/8 is open prior to the compressor starting. Freeze Detection (Coax) - set points shall be either 30°F or 15°F. When the thermistor temperature drops below the selected set point, the control shall begin counting down the 30 seconds delay. If the thermistor value rises above the selected set point, then the count should reset. The resistance value must remain below the selected set point for the entire length of the appropriate delay to be recognized as a fault. This fault will be ignored for the initial 2 minutes of the compressor run time. Over/Under Voltage Shutdown - An over/under voltage condition exists when the control voltage is outside the range of 18 VAC to 30 VAC. If the over/under voltage shutdown lasts for 15 minutes, the lockout and alarm relay will be energized. Over/under voltage shutdown is self- resetting in that if the voltage comes back within range of 18 VAC to 30 VAC for at least 0.5 seconds, then normal operation is restored. Operation Description Power Up - The unit will not operate until all the inputs and safety controls are checked for normal conditions. The unit has a 5 to 80 second random start delay at power up. Then the compressor has a 4 minute anti-short cycle delay after the random start delay. Standby In standby mode, Y1, Y2, W, DH, and G are not active. Input O may be active. The blower and compressor will be off. Heating Operation Heating, 1st Stage (Y1) - The blower is started immediately and the compressor is energized 10 seconds after the Y1 input is received. Heating, 2nd Stage (Y1, Y2) - The compressor will be staged to full capacity 20 seconds after Y2 input is received. The ECM blower will shift to high speed. Heating, 3rd Stage (Y1, Y2, W) - The hot water pump is de- energized and the first stage of electric heat is energized 10 seconds after the W command is received. If the demand continues the second stage of electric heat will be energized after 5 minutes. Emergency Heat (W Only) - When the unit is matched with an air handler listed in the Air Handler Compatibility table, the thermostat will send the "W" input to the air handler's control board. The blower is started on high speed, and the first stage of resistance heat is energized 10 seconds after the "W" input. Continuing demand will engage the additional stages of resistance heat 90 seconds after the first stage. Cooling Operation In all cooling operations, the reversing valve directly tracks the O input. Thus, anytime the O input is present, the reversing valve will be energized. Cooling, 1st Stage (Y1, O) - The blower is started immediately and the compressor is energized 10 seconds after the Y1 input is received. Cooling, 2nd Stage (Y1, Y2, O) - The compressor will be staged to full capacity 20 seconds after Y2 input is received. The ECM blower will shift to high speed. Blower (G) - The blower will start immediately upon receiving a thermostat G command. If there are no other commands from the thermostat the ECM will run on “G” speed until the G command is removed. Regardless of blower input (G) from the thermostat, the blower will remain on for 30 seconds at the end of each heating, cooling, and emergency heat cycle. 14 5 SERIES 500R11 SPECIFICATION CATALOG The Aurora ‘Base’ Control System cont. CC2 FactoryFault ALGALMLSESACC cStatus AuroraTM Base Control RV – K1 CC2CC – K2 CC Hi – K3 Fan – K4 Alarm – K5 Acc – K6 ACC noACC ncO/BCRLOGY1Y2WDH3A-FuseO/BCRLOGY1Y2WDHLOG HICCG CC FG F R HPHP LP FP2 FP2 FP1 REVREV CFMPWMECM PWM FactoryFactory Fan Connection RR CCCC R (-) (+)RS 485EH2CEH1CCO (+)(-)RCRS485ExpFactory Com1 Com2 Config G G G YR SW1 Test FP1 – 15oF/30oF JW2 - Alarm P11 P5 P2 P1 P8 P7 P9 P6 P3 SW2 P13P4 FP2 – 15oF/30oF RV – B/O ACC – Dip 1 ACC – Dip 2 CC – Dual/Single L – Pulse/Continuous Reheat/Normal Factory UseField ConnectionsField ConnectionsCLP FP1 F CC G Y1 1 2 3 4 5 6 7 8 Off On N/A RS485 NETEH1LED 1 LED 3 LED 2 LED 5 LED 4 5.0 in.6.25 in.5.5 in.5.75 in.Emergency Shutdown - Four (4) seconds after a valid ES input, P2-7 is present, all control outputs will be turned off and remain off until the emergency shutdown input is no longer present. The first time that the compressor is started after the control exits the emergency shutdown mode, there will be an anti-short cycle delay followed by a random start delay. Input must be tied to common to activate. Load Shed - The LS input disables all outputs with the exception of the blower output. When the LS input has been cleared, the anti-short cycle timer and random start timer will be initiated. Input must be tied to common to activate. Aurora ‘Base’ Control LED Displays These three LEDs display the status, configuration, and fault codes for the control. These can also be read in plain English via the Aurora AID Tool. Status LED (LED3, Green) Description of Operation Fault LED, Green Normal Mode ON Control is Non-functional OFF Test Mode Slow Flash Lockout Active Fast Flash Dehumidification Mode Flash Code 2 (Future Use) Flash Code 3 (Future Use) Flash Code 4 Load Shed Flash Code 5 ESD Flash Code 6 (Future Use) Flash Code 7 Configuration LED (LED2, Yellow) Description of Operation Configuration LED, Yellow No Software Overwritten Flashing ECM Setting DIP Switch was Overwritten Slow Flash ECM Configuration Mode Fast Flash Fault LED (LED1, Red) Red Fault LED LED Flash Code*Lockout Reset/ Remove ABC Basic FaultsNormal - No Faults OFF – Fault - Input 1 No Auto Fault - High Pressure 2 Yes Hard or Soft Fault - Low Pressure 3 Yes Hard or Soft Fault - Freeze Detection FP2 4 Yes Hard or Soft Fault - Freeze Detection FP1 5 Yes Hard or Soft Fault - Condensate Overflow 7 Yes Hard or Soft Fault - Over/Under Voltage 8 No Auto Fault - FP1 & FP2 Sensor Error 11 Yes Hard or Soft NOTE: All codes >11 use long flash for tens digit and short flash for the ones digit. 20, 30, 40, 50, etc. are skipped. Aurora Interface and Diagnostics (AID) Tool The Aurora Interface and Diagnostics (AID) Tool is a device that is a member of the Aurora network. The AID Tool is used to troubleshoot equipment which uses the Aurora control via Modbus RTU communication. The AID Tool provides diagnostics, fault management, ECM setup, and system configuration capabilities to the Aurora family of controls. An AID Tool is recommended, although not required, for ECM airflow settings. The AID Tool simply plugs into the exterior of the cabinet in the AID Tool port. ABC Control Board Layout 15 5 SERIES 500R11 SPECIFICATION CATALOG In ground water situations where scaling could be heavy or where biological growth such as iron bacteria will be present, a closed loop system is recommended. The heat exchanger coils in ground water systems may, over a period of time, lose heat exchange capabilities due to a buildup of mineral deposits inside. These can be cleaned, but only by a qualified service mechanic, as special solutions and pumping equipment are required. Hot water generator coils can likewise become scaled and possibly plugged. In areas Water Quality with extremely hard water, the owner should be informed that the heat exchanger may require occasional flushing. Units with cupronickel heat exchangers are recommended for open loop applications due to the increased resistance to build-up and corrosion, along with reduced wear caused by acid cleaning. Failure to adhere to the guidelines in the water quality table could result in the loss of warranty. Material Copper 90/10 Cupronickel 316 Stainless Steel pH Acidity/Alkalinity 7 - 9 7 - 9 7 - 9 Scaling Calcium and Magnesium Carbonate (Total Hardness) less than 350 ppm (Total Hardness) less than 350 ppm (Total Hardness) less than 350 ppm Corrosion Hydrogen Sulfide Less than 0.5 ppm (rotten egg smell appears at 0.5 ppm)10 - 50 ppm Less than 1 ppm Sulfates Less than 125 ppm Less than 125 ppm Less than 200 ppm Chlorine Less than 0.5 ppm Less than 0.5 ppm Less than 0.5 ppm Chlorides Less than 20 ppm Less than 125 ppm Less than 300 ppm Carbon Dioxide Less than 50 ppm 10 - 50 ppm 10 - 50 ppm Ammonia Less than 2 ppm Less than 2 ppm Less than 20 ppm Ammonia Chloride Less than 0.5 ppm Less than 0.5 ppm Less than 0.5 ppm Ammonia Nitrate Less than 0.5 ppm Less than 0.5 ppm Less than 0.5 ppm Ammonia Hydroxide Less than 0.5 ppm Less than 0.5 ppm Less than 0.5 ppm Ammonia Sulfate Less than 0.5 ppm Less than 0.5 ppm Less than 0.5 ppm Total Dissolved Solids (TDS) Less than 1000 ppm 1000 - 1500 ppm 1000 - 1500 ppm LSI Index +0.5 to -0.5 +0.5 to -0.5 +0.5 to -0.5 Iron Fouling (Biological Growth) Iron, FE2+ (Ferrous) Bacterial Iron Potential < 0.2 ppm < 0.2 ppm < 0.2 ppm Iron Oxide Less than 1 ppm, above this level deposition will occur Less than 1 ppm, above this level deposition will occur Less than 1 ppm, above this level deposition will occur Erosion Suspended Solids Less than 10 ppm and filtered for max. of 600 micron size Less than 10 ppm and filtered for max. of 600 micron size Less than 10 ppm and filtered for max. of 600 micron size Threshold Velocity (Fresh Water)< 6 ft/sec < 6 ft/sec < 6 ft/sec NOTES: Grains = ppm divided by 17 mg/L is equivalent to ppm 2/22/12 16 5 SERIES 500R11 SPECIFICATION CATALOG Dimensional Data Dimensions are in inches. Decorative molding and water connections extend 1.2 in. [30.5 mm] beyond the front of the cabinet. Models Height Width Depth Water In Water Out Service Valve HWG In HWG Out Low Voltage External Pump Line Voltage Knock Out Knock OutLiquid Gas ABCDEFGH JKLMNP 022-030 in. 19.30 22.50 26.50 1.93 6.93 15.20 16.80 9.40 11.90 12.10 14.30 9.50 4.60 8.20 cm. 49.00 57.10 67.30 4.90 17.60 38.60 42.70 23.90 30.20 30.70 36.30 24.10 11.70 20.80 036-072 in. 21.25 25.62 31.60 2.30 7.21 16.40 18.30 10.30 13.30 12.10 14.30 9.50 4.70 9.10 cm. 54.00 65.10 80.30 5.80 18.50 41.70 46.50 26.20 33.80 30.70 36.30 24.10 11.90 23.10 MKL A D E H J F G N P C B 17 5 SERIES 500R11 SPECIFICATION CATALOG Physical Data Model 022 030 036 042 048 060 070 026 038 049 064 72 Compressor (1 each) Single Speed Scroll Dual Capacity Scroll Factory Charge R410a, oz [kg]5 6 [1.59] 56 [1.59] 5 6 [1.59] 74 [2.1] 9 0 [2.55] 92 [2.61] 108 [3.06] 52 [1.47] 5 6 [1.59] 9 0 [2.55] 92 [2.61] 104 [2.95] Coax and Water Piping Water Connections Size - Swivel- in [mm] 1 [25.4] 1 [25.4] HWG Connection Size - Female Sweat (I.D.) - in [mm]1/2 [12.7] 1/2 [12.7] Brass Service Valve - Liquid Line - in [mm]3/8 [9.525] 1/2 [12.7] 3/8 [9.525] 1/2 [12.7] Brass Service Valve - Suction Line - in [mm]5/8 [15.875] 3/4 [19.05] 7/8 [22.225] 5/8 [15.875] 3/4 [19.05] 7/8 [22.225] Coax and Piping Water Volume - gal [l]0.7 [2.6] 1.0 [3.8] 1.3 [4.9] 1.3 [4.9] 1.6 [6.1] 1.6 [6.1] 2.3 [8.7] 0.7 [2.6] 1.3 [4.9] 1.6 [6.1] 1.6 [6.1] 2.3 [8.7] Weight - Operating, lb [kg]164 [74] 174 [79] 212 [96] 213 [97] 246 [112] 251 [114] 2 9 2 [132] 189 [186] 236 [107] 250 [113] 2 7 1 [123] 290 [132] Weight - Packaged, lb [kg]184 [83] 194 [88] 232 [105] 233 [106] 266 [121] 27 1 [123] 312 [142] 209 [95] 256 [116] 270 [122] 291 [132] 310 [141] 6/27/11NOTES: All units have TXV expansion devices, and 1/2 in. [12.2 mm] and 3/4 in. [19.1 mm] electrical knockouts. Brass service valves are sweat type valves. Model Rated Voltage Voltage Min/Max Compressor HWA Pump FLA Ext Loop FLA Total Unit FLA Min Circ Amp Max Fuse/ HACRMCC RLA LRA LRA* 022 208-230/60/1 187/253 14.0 9.0 48.0 17.0 0.4 5.4 14.8 17.1 25 030 208-230/60/1 187/253 20.0 12.8 58.3 21.0 0.4 5.4 18.6 21.8 30 036 208-230/60/1 187/253 22.0 14.1 73.0 26.0 0.4 5.4 19.9 23.4 35 042 208-230/60/1 187/253 26.0 16.6 79.0 28.0 0.4 5.4 22.4 26.6 40 048 208-230/60/1 187/253 31.0 19.8 109.0 38.0 0.4 5.4 25.6 30.6 50 060 208-230/60/1 187/253 41.2 26.4 134.0 47.0 0.4 5.4 32.2 38.8 60 070 208-230/60/1 187/253 44.2 28.3 158.0 63.0 0.4 5.4 34.1 41.2 70 026 208-230/60/1 187/253 18.2 11.6 58.3 21.0 0.4 5.4 17.4 20.3 30 038 208-230/60/1 187/253 23.8 15.2 83.0 30.0 0.4 5.4 21.0 24.8 40 049 208-230/60/1 187/253 33.0 21.1 104.0 37.0 0.4 5.4 26.9 32.2 50 064 208-230/60/1 187/253 42.3 27.1 152.9 54.0 0.4 5.4 32.9 39.7 70 072 208-230/60/1 187/253 46.3 29.6 179.2 63.0 0.4 5.4 35.4 42.8 75 4/3/13Rated voltage of 208-230/60/1 HACR circuit breaker in USA only All fuses Class RK-5 * With optional IntelliStart Electrical Data 18 5 SERIES 500R11 SPECIFICATION CATALOG Model Nomenclature - Air Handler Air Handler Compatibility NAH 036 *00 0 1 R 1-3 4-6 7 8-9 10 11 12 Model NAH – Envision Series Air Handler Unit CapacityRefrigeration (DX) Models with Nominal CFM 022 MBTUH 800 026 MBTUH 925 030 MBTUH 980 036 MBTUH 1225 042 MBTUH 1425 048 MBTUH 1625 060 MBTUH 1760 Hydronic Models with Nominal CFM 026 MBTUH 925 036 MBTUH 1225 048 MBTUH 1625 060 MBTUH 1760 Vintage * = Factory Use Only Air Coil R – Refrigerant H - Hydronic Motor 1 – ECM 208-230/60/1 Disconnect 0 – No Breaker Installed (only on 5kW & 10kW Heaters) 1 – Breaker Installed (only on 15kW & 20kW Heaters) Electric Heat 00 – None 05 – 5kW (022 – 036 only) 10 – 10kW (030 – 060 only) 15 – 15kW (042 – 060 only) 20 – 20kW (060 only) Rev.: 08 April 2013D NOTE: To field convert the NAH042-060 to bottomflow air discharge, the NAHBC kit must be ordered. Air Handler Sizing Selection The Envision Air Handlers are designed for R-410A refrigerant and should be matched with 5 Series Split compressor section according to the table below. Air Handler Indoor Split Model (Single) Indoor Split Model (Dual Capacity) Outdoor Split Model (Dual Capacity)Airfl ow (CFM) Electric Heat (kW) NAH022****1R NSZ022 - 800 5 NAH026****1R - NDZ026 NDS026 925 5 NAH030****1R NSZ030 - - 980 5, 10 NAH036****1R NSZ036 - - 1225 5, 10 NAH036****1R - NDZ038 NDS038 1225 5, 10 NAH042****1R NSZ042 - - 1425 10, 15 NAH048****1R NSZ048 - - 1625 10, 15 NAH048****1R - NDZ049 NDS049 1625 10, 15 NAH060****1R NSZ060 - - 1760 10, 15, 20 NAH060****1R - NDZ064 NDS064 1760 10, 15, 20 NAH060****1R NSZ070 - - 1760 10, 15, 20 NAH060****1R - NDZ072 NDS072 1760 10, 15, 20 19 5 SERIES 500R11 SPECIFICATION CATALOG Physical Data - Air Handler Line Set Sizes Air Handler Model Number (Refrigerant) NAH022 NAH026 NAH030 NAH036 NAH042 NAH048 NAH060 Evaporator Coil Air Coil Total Face Area - ft2 [m2] 5.83 [0.54] Tube Outside Diameter - in [mm] 3/8 [9.52] Number of Rows 2 3 Fins Per Inch 12 Suction Line Connection - in [mm] Sweat 5/8 [15.87] 7/8 [22.22] Liquid Line Connection - in [mm] Sweat 3/8 [9.52] Refrigerant R-410a Nominal Cooling Capacity - Ton [kW] 1.8 [6.44] 2.1 [7.59] 2.5 [8.79] 3.0 [10.55] 3.5 [12.30] 4.0 [14.06] 5 [17.58] Condensate Drain Connection - (FPT) in [mm] 3/4 [19.05] Blower Wheel Size - (Dia x W) in [mm] 11 x 10 [279 x 254] Blower Motor Type/Speeds Variable Speed ECM Blower Motor Output - hp [W] 1/2 [373] 1 [746] Filter Standard - 1" [51mm] MERV3 Disposable - in [mm] 20 x 24 [508 x 635] Electrical Characteristics (60hz)208/230/60/1 Shipping Weight - lbs [kg] 215 [97.52] 220 [99.79] Operating Weight - lbs [kg] 195 [88.45] 200 [90.71] 04/10/13 NOTES: * The "Charge Amount with NAH Air Handler" column is based on the charge amount for a NAH Air Handler+Compressor Section/Split. Additional charge will have to be added accordingly for line set length. After Charge is added adjustments can be made to get appropriate subcooling and superheat. Additional charge for R-410A is 0.50 oz. per ft. for 3/8 in. and 1.0 oz. per ft. for 1/2 in. tube. Unit Size Air Handler 20 feet 40 feet 60 feet Factory Charge (oz.) *Charge Amount with NAH Air Handler (oz.)Suction Liquid Suction Liquid Suction Liquid 022 NAH022 5/8” OD 3/8” OD 5/8” OD 3/8” OD 3/4” OD 3/8” OD 56 78 030 NAH030 5/8” OD 3/8” OD 3/4” OD 3/8” OD 3/4” OD 3/8” OD 56 78 036 NAH036 5/8” OD 3/8” OD 3/4” OD 3/8” OD 3/4” OD 1/2” OD 56 86 042 NAH042 3/4” OD 3/8” OD 3/4” OD 3/8” OD 7/8” OD 1/2” OD 74 99 048 NAH048 3/4” OD 3/8” OD 7/8” OD 3/8” OD 7/8” OD 1/2” OD 90 115 060 NAH060 7/8” OD 1/2” OD 7/8” OD 1/2” OD 1-1/8” OD 1/2” OD 92 112 070 NAH060 7/8” OD 1/2” OD 7/8” OD 1/2” OD 1-1/8” OD 1/2” OD 108 132 026 NAH026 5/8” OD 3/8” OD 3/4” OD 3/8” OD 3/4” OD 1/2” OD 52 74 038 NAH036 3/4” OD 3/8” OD 3/4” OD 3/8” OD 3/4” OD 1/2” OD 56 86 049 NAH048 3/4” OD 3/8” OD 7/8” OD 3/8” OD 7/8” OD 1/2” OD 90 115 064 NAH060 7/8” OD 1/2” OD 7/8” OD 1/2” OD 1-1/8” OD 1/2” OD 92 112 072 NAH060 7/8” OD 1/2” OD 7/8” OD 1/2” OD 1-1/8” OD 1/2” OD 104 132 4/6/10 20 5 SERIES 500R11 SPECIFICATION CATALOG Model Nomenclature - Coil Refrigerant Coil Compatibility NR A C 026 C 1-2 3 4 5-7 8 Model NR – Envision Series Refrigerant Coil NH – Envision Series Hydronic Coil Configuration A – “A” Coil Type C - Coil Cabinet C – Enclosed (Cased) U - Uncased Capacity Refrigerant (DX) Models 026 MBTUH 036 MBTUH 048 MBTUH 060 MBTUH Hydronic Models 060 MBTUH Rev.: 08 April 2013D NOTE: All refrigerant coils include TXV. Encased/Uncased Coil Indoor Split Model (Single) Indoor Split Model (Dual Capacity) Outdoor Split Model (Dual Capacity) Recommended Airfl ow (CFM) NRAC026*NSZ022 - 800 NRAC026*- NDZ026 NDS026 925 NRAC026*NSZ030 - - 980 NRAC036*NSZ036 - - 1225 NRAC036*- NDZ038 NDS038 1225 NRAC048*NSZ042 - - 1425 NRAC048*NSZ048 - - 1625 NRAC048*- NDZ049 NDS049 1625 NRAC060*NSZ060 - - 1760 NRAC060*- NDZ064 NDS064 1760 NRAC060*NSZ070 - - 1760 NRAC060*- NDZ072 NDS072 1760 7/14/08 21 5 SERIES 500R11 SPECIFICATION CATALOG Reference Calculations Legend and Notes cfm = airflow, cubic feet/minute EWT = entering water temperature, Fahrenheit gpm = water flow in gallons/minute WPD = water pressure drop, PSI and feet of water EAT = entering air temperature, Fahrenheit (dry bulb/wet bulb) HC = air heating capacity, MBtu/h TC = total cooling capacity, MBtu/h SC = sensible cooling capacity, MBtu/h kW = total power unit input, kilowatts HR = total heat of rejection, MBtu/h HE = total heat of extraction, MBtu/h HWC = hot water generator capacity, MBtu/h EER = Energy Efficient Ratio = Btu output/Watt input COP = Coefficient of Performance = Btu output/Btu input LWT = leaving water temperature, °F LAT = leaving air temperature, °F TH = total heating capacity, MBtu/h LC = latent cooling capacity, MBtu/h S/T = sensible to total cooling ratio Hot water generator capacity based on 0.4 gpm flow per nominal unit ton at 90°F entering hot water temperature. Performance Data tables do not include water pumping watts and are based upon 15% (by volume) methanol antifreeze solution. Multiple Flow Rates (for EWT) are shown in the Performance Data tables. The lowest flow rate shown is used for geothermal open loop/well water systems with a minimum 50° F. The second flow rate shown is the minimum geothermal closed loop flow rate. The third flow rate shown is optimum for geothermal closed loop and the suggested flow rate for boiler tower applications. Interpolation between EWT, gpm and cfm data is permissible. Extrapolation for heating data down to 25°F is permissible. Catalog illustrations cover the general appearance of products at time of publication. We reserve the right to make changes in design and construction at any time without notice. ABBREVIATIONS AND DEFINITIONS: Heating Calculations:Cooling Calculations: LWT = EWT + LAT(DB) = EAT(DB) - LC = TC - SC S/T = HR gpm x 500 SC cfm x 1.08 SC TC HE gpm x 500LWT = EWT - LAT = EAT + TH = HC + HWC HC cfm x 1.08 22 5 SERIES 500R11 SPECIFICATION CATALOG Cooling -- No Hot Water Generator Entering Water Temp °F Water Flow gpm/Ton NSZ022 thru NSZ060 NSZ070 NSZ022 thru NSZ070 Suction Pressure PSIG Discharge Pressure PSIG Suction Pressure PSIG Discharge Pressure PSIG Superheat Subcooling Water Temp Rise °F Air Temp Drop °F DB 50 1.5 115-150 205-245 115-130 205-245 12-22 7-14 5-22 18-24 3.0 110-145 200-235 110-125 200-235 14-26 6-12 8-12 18-24 70 1.5 125-160 260-300 125-160 275-300 8-14 8-12 5-19 18-22 3.0 115-150 265-295 115-135 265-295 9-16 4-16 5-12 18-22 90 1.5 125-160 320-370 125-160 330-370 8-14 6-13 14-22 18-22 3.0 120-150 305-355 120-150 325-365 9-16 4-16 5-12 18-22 Heating -- No Hot Water Generator Entering Water Temp °F Water Flow gpm/Ton NSZ022 thru NSZ060 NSZ070 NSZ022 thru NSZ070 Suction Pressure PSIG Discharge Pressure PSIG Suction Pressure PSIG Discharge Pressure PSIG Superheat Subcooling Water Temp Drop °F Air Temp Rise °F DB 30 1.5 65-85 290-310 65-85 330-360 7-13 2-21 7-10 18-24 3.0 70-90 265-330 70-90 335-365 6-12 2-21 3-7 22-26 50 1.5 95-120 320-345 95-120 395-430 6-12 2-21 5-11 21-34 3.0 100-125 280-365 100-125 375-405 6-12 4-22 5-11 24-33 70 1.5 135-155 315-380 135-155 435-485 8-14 10-20 8-14 26-46 3.0 135-156 315-395 135-155 440-490 8-14 10-20 3-10 25-48 Operating Parameters Single Speed Models - NSZ022 thru NSZ070 (with NAH Series Air Handler) NOTES: Cooling performance based on entering air temperatures of 80°F DB, 67°F WB. Heating performance based on entering air temperatures of 70°DB. 5/29/08 Operating Limits Operating Limits Cooling Heating (°F) (°C) (°F) (°C) Air Limits Min. Ambient Air 45 7.2 45 7.2 Rated Ambient Air 80 26.7 70 21.1 Max. Ambient Air 100 37.8 85 29.4 Min. Entering Air 50 10.0 40 4.4 Rated Entering Air db/wb 80.6/66.2 27/19 68 20.0 Max. Entering Air db/wb 110/83 43/28.3 80 26.7 Water Limits Min. Entering Water 30 -1.1 20 -6.7 Normal Entering Water 50-110 10-43.3 30-70 -1.1 Max. Entering Water 120 48.9 90 32.2 NOTE: Minimum/maximum limits are only for start-up conditions, and are meant for bringing the space up to occupancy temperature. Units are not designed to operate at the minimum/maximum conditions on a regular basis. The operating limits are dependant upon three primary factors: 1) water temperature, 2) return air temperature, and 3) ambient temperature. When any of the factors are at the minimum or maximum levels, the other two factors must be at the normal level for proper and reliable unit operation. 23 5 SERIES 500R11 SPECIFICATION CATALOG Operating Parameters NDZ026 thru NDZ072 (with NAH Series Air Handler) First Stage Operation Cooling -- No Hot Water Generator Entering Water Temp °F Water Flow gpm/Ton NDZ026 thru NDZ064 NDZ072 NDZ026 thru NDZ072 Suction Pressure PSIG Discharge Pressure PSIG Suction Pressure PSIG Discharge Pressure PSIG Superheat Subcooling Water Temp Rise °F Air Temp Drop °F DB 50 1.5 130-150 193-230 130-150 200-245 8-16 7-14 7-20 18-24 3.0 128-153 190-230 125-140 205-240 8-16 3-10 9-14 18-25 70 1.5 130-150 238-282 135-150 240-280 6-16 4-16 9-18 18-25 3.0 130-155 238-262 125-145 245-270 6-18 5-11 5-10 18-24 90 1.5 133-148 308-340 130-155 300-365 7-16 6-18 4-11 19-25 3.0 138-153 303-333 130-165 305-350 7-18 7-14 5-9 17-22 Heating -- No Hot Water Generator Entering Water Temp °F Water Flow gpm/Ton NDZ026 thru NDZ064 NDZ072 NDZ026 thru NDZ072 Suction Pressure PSIG Discharge Pressure PSIG Suction Pressure PSIG Discharge Pressure PSIG Superheat Subcooling Water Temp Drop °F Air Temp Rise °F DB 30 1.5 78-100 275-325 85-105 325-385 6-11 4-16 2-8 20-29 3.0 78-110 285-325 90-120 335-375 6-11 4-16 3-7 20-32 50 1.5 105-120 305-350 100-130 340-400 5-12 4-16 5-12 24-32 3.0 110-125 305-355 110-125 345-395 9-15 2-14 4-9 20-34 70 1.5 140-155 305-355 130-165 370-430 5-12 2-14 8-12 24-39 3.0 145-160 330-360 140-160 375-425 7-17 7-15 4-9 24-39 Second Stage Operation Cooling -- No Hot Water Generator Entering Water Temp °F Water Flow gpm/Ton NDZ026 thru NDZ064 NDZ072 NDZ026 thru NDZ072 Suction Pressure PSIG Discharge Pressure PSIG Suction Pressure PSIG Discharge Pressure PSIG Superheat Subcooling Water Temp Rise °F Air Temp Drop °F DB 50 1.5 120-140 200-245 105-150 210-270 7-17 6-14 7-16 19-26 3.0 115-140 195-290 110-130 215-260 7-15 4-11 8-12 20-24 70 1.5 121-136 265-310 105-150 280-350 9-15 6-18 7-15 19-25 3.0 123-139 265-310 110-140 285-320 10-16 8-16 8-12 18-24 90 1.5 122-140 310-360 115-140 325-385 8-14 6-18 10-16 18-24 3.0 123-139 310-350 120-135 330-355 8-14 7-15 8-12 17-23 Heating -- No Hot Water Generator Entering Water Temp °F Water Flow gpm/Ton NDZ026 thru NDZ064 NDZ072 NDZ026 thru NDZ072 Suction Pressure PSIG Discharge Pressure PSIG Suction Pressure PSIG Discharge Pressure PSIG Superheat Subcooling Water Temp Drop °F Air Temp Rise °F DB 30 1.5 72-89 295-350 70-100 320-370 7-18 10-20 4-13 18-24 3.0 73-87 305-330 75-90 315-365 7-18 10-20 4-16 18-27 50 1.5 100-120 320-365 95-130 375-430 6-14 6-18 4-10 23-34 3.0 105-120 355-365 100-125 370-420 6-14 6-18 4-9 20-37 70 1.5 142-158 360-380 130-165 400-470 6-12 4-15 6-15 28-38 3.0 138-152 365-390 135-160 405-465 7-14 4-15 6-12 24-42 NOTES: Cooling performance based on entering air temperatures of 80°F DB, 67°F WB. Heating performance based on entering air temperatures of 70°DB. 5/29/08 24 5 SERIES 500R11 SPECIFICATION CATALOG Pressure Drop Single Speed Dual Capacity Model GPM Pressure Drop (PSI) 30°F 50°F 70°F 90°F 110°F 022 3 4.5 6 8 0.9 1.7 2.8 4.7 0.9 1.6 2.7 4.4 0.8 1.5 2.5 4.1 0.7 1.4 2.3 3.9 0.7 1.3 2.2 3.6 030 4 6 8 10 1.3 2.7 4.5 6.8 1.2 2.5 4.2 6.3 1.2 2.4 3.9 5.4 1.1 2.2 3.7 5.4 1.0 2.2 3.4 5.0 036 5 7 9 12 1.0 2.1 3.6 6.3 1.0 1.9 3.3 5.9 0.9 1.8 3.0 5.5 0.8 1.7 2.8 5.1 0.8 1.6 2.6 4.8 042 5 8 11 14 0.8 2.1 4.2 7.6 0.7 2.1 4.1 6.7 0.7 1.9 3.8 6.3 0.7 1.8 3.5 5.8 0.6 1.7 3.3 5.4 048 6 9 12 16 1.1 2.3 3.9 6.7 1.0 2.1 3.7 6.3 1.0 2.0 3.4 5.9 0.9 1.9 3.2 5.5 0.8 1.7 3.0 5.1 060 9 12 15 20 2.4 3.9 5.7 9.5 2.2 3.6 5.3 8.9 2.1 3.4 5.0 8.3 2.0 3.2 4.7 7.8 1.8 2.9 4.3 7.2 070 12 15 18 24 3.0 4.4 6.0 9.7 2.8 4.0 5.5 9.1 2.6 3.8 5.1 8.5 2.4 3.5 4.8 7.9 2.2 3.3 4.4 7.3 5/28/13 Model GPM Pressure Drop (psi) 30°F 50°F 70°F 90°F 110°F 026 full load 4 6 8 10 1.4 2.8 4.7 7.0 1.3 2.6 4.4 6.6 1.2 2.4 4.1 6.2 1.1 2.3 3.8 5.8 1.0 2.1 3.5 5.3 026 part load 3 5 7 9 0.8 2.0 3.6 5.8 0.7 1.8 3.4 5.5 0.7 1.7 3.2 5.1 0.7 1.6 3.0 4.8 0.6 1.5 2.8 4.4 038 full load 5 7 9 11 1.2 2.2 3.4 4.9 1.2 2.1 3.2 4.6 1.1 1.9 3.0 4.3 1.0 1.8 2.8 4.0 1.0 1.7 2.6 3.7 038 part load 4 6 8 10 0.9 1.7 2.8 4.2 0.8 1.6 2.6 3.9 0.8 1.5 2.5 3.7 0.7 1.4 2.3 3.4 0.7 1.3 2.1 3.2 049 full load 6 9 12 15 1.2 2.4 3.9 5.7 1.2 2.2 3.6 5.3 1.1 2.1 3.4 5.0 1.0 2.0 3.2 4.7 1.0 1.8 2.9 4.3 049 part load 5 8 11 14 0.9 2.0 3.4 5.0 0.9 1.8 3.1 4.7 0.8 1.7 2.9 4.4 0.8 1.6 2.8 4.1 0.7 1.5 2.5 3.8 064 full load 8 12 16 20 1.8 3.8 6.5 9.7 1.7 3.5 6.0 9.1 1.6 3.3 5.6 8.5 1.4 3.0 5.2 8.0 1.3 2.8 4.8 7.4 064 part load 6 10 14 18 1.0 2.6 5.0 8.1 0.9 2.5 4.7 7.6 0.9 2.3 4.4 7.1 0.8 2.1 4.1 6.6 0.8 2.0 3.8 6.1 072 full load 12 15 18 21 3.2 4.5 6.0 7.8 3.0 4.2 5.7 7.3 2.8 4.0 5.3 6.8 2.6 3.7 4.9 6.4 2.4 3.4 4.6 5.9 072 part load 10 13 16 19 2.3 3.6 5.0 6.5 2.1 3.3 4.6 6.2 2.0 3.0 4.3 5.8 1.9 2.8 4.0 5.4 1.7 2.6 3.7 5.0 5/30/06 25 5 SERIES 500R11 SPECIFICATION CATALOG NSZ022 - Performance Data NSZ022 - Single Speed (700 cfm) EWT °F Flow GPM WPD HEATING - EAT 70°F COOLING - EAT 80/67 °F PSI FT Airflow CFM HC kBtuh Power kW HE kBtuh LAT °F COP HWC kBtuh Airflow CFM TC kBtuh SC kBtuh S/T Ratio Power kW HR kBtuh EER HWC kBtuh 20 3.0 0.9 2.2 Operation not recommended Operation not recommended4.5 1.8 4.2 6.0 2.9 6.8 600 12.1 1.18 8.1 88.7 3.02 1.6 700 12.3 1.19 8.3 86.3 3.03 1.5 30 3.0 0.9 2.1 Operation not recommended Operation not recommended 4.5 1.7 4.0 600 14.3 1.19 10.2 92.0 3.52 1.7 600 21.8 14.8 0.68 0.63 24.0 34.8 - 700 14.6 1.20 10.5 89.3 3.56 1.6 700 22.2 16.1 0.73 0.66 24.4 33.6 - 6.0 2.8 6.6 600 14.6 1.20 10.5 92.5 3.56 1.8 600 21.9 14.8 0.67 0.61 24.0 36.1 - 700 14.8 1.21 10.6 89.5 3.58 1.6 700 22.5 16.1 0.72 0.64 24.6 35.2 - 40 3.0 0.9 2.0 Operation not recommended Operation not recommended 4.5 1.7 3.9 600 16.8 1.22 12.7 96.0 4.05 1.9 600 22.5 14.7 0.65 0.69 24.9 32.9 - 700 17.2 1.22 13.0 92.7 4.11 1.8 700 23.0 16.1 0.70 0.72 25.4 32.0 - 6.0 2.8 6.4 600 17.1 1.23 12.9 96.4 4.07 2.0 600 22.7 14.7 0.65 0.67 25.0 34.2 - 700 17.4 1.23 13.2 93.1 4.15 1.8 700 23.2 16.1 0.69 0.70 25.6 33.4 - 50 3.0 0.9 2.0 600 18.2 1.22 14.1 98.2 4.37 2.1 600 23.0 14.5 0.63 0.80 25.7 28.6 1.0 700 18.6 1.22 14.4 94.6 4.46 1.9 700 23.5 15.8 0.67 0.84 26.3 28.1 1.1 4.5 1.6 3.8 600 19.2 1.25 14.9 99.6 4.49 2.1 600 23.2 14.6 0.63 0.76 25.8 30.4 1.0 700 19.5 1.25 15.3 95.8 4.58 2.0 700 23.7 15.9 0.67 0.80 26.4 29.8 1.0 6.0 2.7 6.2 600 19.4 1.27 15.1 100.0 4.49 2.2 600 23.5 14.6 0.62 0.74 26.0 31.7 0.9 700 19.9 1.26 15.6 96.3 4.63 2.0 700 24.0 15.9 0.67 0.77 26.6 31.0 1.0 60 3.0 0.8 1.9 600 20.6 1.27 16.3 101.8 4.75 2.3 600 22.2 14.4 0.65 0.90 25.3 24.7 1.2 700 21.1 1.26 16.8 97.9 4.91 2.2 700 22.7 15.6 0.69 0.94 25.9 24.2 1.3 4.5 1.6 3.7 600 21.6 1.30 17.2 103.3 4.88 2.4 600 22.5 14.5 0.65 0.85 25.4 26.3 1.1 700 22.1 1.29 17.7 99.3 5.03 2.2 700 22.9 15.8 0.69 0.89 26.0 25.8 1.2 6.0 2.6 6.0 600 21.9 1.31 17.5 103.9 4.89 2.5 600 22.7 14.5 0.64 0.83 25.5 27.3 1.1 700 22.5 1.30 18.1 99.8 5.08 2.3 700 23.1 15.8 0.68 0.86 26.1 26.9 1.2 70 3.0 0.8 1.8 600 23.0 1.32 18.5 105.5 5.10 2.6 600 22.0 14.3 0.65 1.02 25.5 21.5 1.5 700 23.6 1.30 19.1 101.2 5.33 2.4 700 22.4 15.5 0.69 1.06 26.0 21.1 1.6 4.5 1.5 3.6 600 24.0 1.35 19.4 107.1 5.22 2.7 600 22.1 14.4 0.65 0.96 25.4 23.0 1.4 700 24.8 1.33 20.2 102.7 5.45 2.5 700 22.7 15.7 0.69 1.00 26.1 22.6 1.5 6.0 2.5 5.8 600 24.5 1.37 19.8 107.8 5.25 2.8 600 22.4 14.4 0.64 0.94 25.6 23.8 1.3 700 25.1 1.34 20.5 103.2 5.50 2.6 700 22.8 15.7 0.69 0.97 26.2 23.5 1.5 80 3.0 0.8 1.8 600 25.0 1.38 20.3 108.6 5.32 2.9 600 21.0 13.9 0.66 1.16 25.0 18.1 1.9 700 25.7 1.34 21.1 104.0 5.61 2.7 700 21.5 15.1 0.70 1.20 25.6 17.9 2.0 4.5 1.5 3.4 600 26.1 1.41 21.3 110.3 5.43 3.0 600 21.2 14.1 0.66 1.10 24.9 19.3 1.8 700 27.0 1.37 22.3 105.6 5.75 2.8 700 21.7 15.3 0.71 1.13 25.6 19.1 1.9 6.0 2.4 5.6 600 26.5 1.43 21.7 111.0 5.46 3.1 600 21.5 14.1 0.65 1.06 25.1 20.2 1.6 700 27.4 1.39 22.7 106.2 5.79 2.9 700 21.9 15.3 0.70 1.10 25.6 19.9 1.8 90 3.0 0.7 1.7 600 27.0 1.44 22.1 111.7 5.51 3.3 600 19.4 13.6 0.70 1.32 23.9 14.8 2.4 700 27.9 1.40 23.2 107.0 5.87 3.0 700 19.9 14.7 0.74 1.36 24.5 14.6 2.5 4.5 1.4 3.3 600 28.2 1.47 23.2 113.5 5.61 3.4 600 19.6 13.7 0.70 1.25 23.9 15.7 2.2 700 29.2 1.42 24.4 108.6 6.02 3.1 700 20.0 14.9 0.74 1.28 24.4 15.6 2.4 6.0 2.3 5.4 600 28.7 1.49 23.6 114.2 5.63 3.5 600 19.9 13.7 0.69 1.21 24.0 16.5 2.1 700 29.7 1.44 24.8 109.3 6.06 3.2 700 20.2 14.9 0.74 1.25 24.5 16.2 2.3 100 3.0 0.7 1.7 Operation not recommended Operation not recommended 4.5 1.4 3.2 600 18.8 13.4 0.71 1.41 23.6 13.3 2.7 700 19.2 14.5 0.76 1.45 24.2 13.2 3.0 6.0 2.2 5.2 600 19.0 13.4 0.70 1.37 23.7 13.9 2.5 700 19.4 14.5 0.75 1.41 24.2 13.7 2.8 110 3.0 0.7 1.6 Operation not recommended 4.5 1.3 3.1 600 16.9 12.9 0.76 1.59 22.3 10.6 3.3 700 17.3 14.0 0.81 1.64 22.8 10.5 3.6 6.0 2.2 5.0 600 17.1 12.9 0.75 1.54 22.4 11.1 3.1 700 17.4 14.0 0.80 1.59 22.9 11.0 3.4 120 3.0 0.7 1.5 Operation not recommended 4.5 1.3 2.9 600 15.6 12.4 0.80 1.80 21.8 8.7 4.0 700 15.9 13.5 0.85 1.85 22.3 8.6 4.3 6.0 2.1 4.8 600 15.8 12.4 0.79 1.75 21.7 9.0 3.7 700 16.1 13.5 0.84 1.80 22.3 9.0 4.1 Multiple Flow Rates (for EWT) are shown in the table above. The lowest flow rate shown is used for geothermal open loop/well water systems with a minimum 50° F. The second flow rate shown is the minimum geothermal closed loop flow rate. The third flow rate shown is optimum for geothermal closed loop and the suggested flow rate for boiler tower applications. 26 5 SERIES 500R11 SPECIFICATION CATALOG NSZ030 - Performance Data NSZ030 - Single Speed (900 cfm) EWT °F Flow GPM WPD HEATING - EAT 70°F COOLING - EAT 80/67 °F PSI FT Airflow CFM HC kBtuh Power kW HE kBtuh LAT °F COP HWC kBtuh Airflow CFM TC kBtuh SC kBtuh S/T Ratio Power kW HR kBtuh EER HWC kBtuh 20 4.0 1.5 3.5 Operation not recommended Operation not recommended6.0 3.1 7.2 8.0 5.2 12.1 700 16.6 1.52 11.4 92.0 3.19 2.2 900 16.9 1.56 11.6 87.4 3.18 1.9 30 4.0 1.5 3.4 Operation not recommended Operation not recommended 6.0 3.0 7.0 700 19.1 1.52 13.9 95.2 3.68 2.3 700 24.3 15.5 0.64 0.83 27.1 29.4 - 900 19.5 1.55 14.2 90.0 3.69 2.1 900 24.9 17.4 0.70 0.89 28.0 27.9 - 8.0 5.1 11.8 700 19.5 1.53 14.3 95.9 3.74 2.4 700 24.5 15.5 0.63 0.81 27.2 30.1 - 900 19.9 1.56 14.5 90.5 3.73 2.2 900 25.3 17.3 0.68 0.86 28.3 29.4 - 40 4.0 1.4 3.3 Operation not recommended Operation not recommended 6.0 2.9 6.8 700 22.3 1.57 17.0 99.5 4.17 2.6 700 26.3 16.8 0.64 0.90 29.4 29.0 - 900 22.9 1.59 17.4 93.5 4.21 2.4 900 27.0 18.8 0.70 0.97 30.4 27.8 - 8.0 4.9 11.4 700 22.9 1.59 17.4 100.2 4.22 2.7 700 26.5 16.7 0.63 0.89 29.6 29.9 - 900 23.3 1.61 17.9 94.0 4.26 2.4 900 27.4 18.8 0.68 0.94 30.6 29.1 - 50 4.0 1.4 3.2 700 24.5 1.61 19.0 102.4 4.45 2.8 700 28.1 17.9 0.64 1.04 31.6 26.9 1.3 900 25.0 1.63 19.5 95.7 4.51 2.6 900 28.9 20.2 0.70 1.11 32.7 26.0 1.4 6.0 2.8 6.6 700 25.3 1.62 19.7 103.4 4.58 2.9 700 28.1 18.1 0.64 1.00 31.6 28.0 1.2 900 25.9 1.63 20.3 96.6 4.65 2.6 900 29.0 20.3 0.70 1.07 32.6 27.1 1.3 8.0 4.8 11.1 700 25.8 1.64 20.2 104.2 4.62 3.0 700 28.4 18.1 0.64 0.99 31.8 28.9 1.1 900 26.5 1.65 20.8 97.2 4.71 2.7 900 29.3 20.3 0.69 1.04 32.9 28.1 1.3 60 4.0 1.4 3.1 700 27.4 1.68 21.7 106.3 4.79 3.1 700 27.4 17.6 0.64 1.15 31.3 23.9 1.6 900 28.2 1.68 22.4 99.0 4.91 2.9 900 28.2 19.8 0.70 1.22 32.4 23.2 1.7 6.0 2.8 6.4 700 28.4 1.70 22.6 107.5 4.90 3.2 700 27.5 17.7 0.65 1.10 31.2 24.9 1.5 900 29.2 1.69 23.4 100.0 5.05 3.0 900 28.3 19.8 0.70 1.17 32.3 24.2 1.6 8.0 4.6 10.7 700 28.9 1.72 23.1 108.3 4.94 3.3 700 27.8 17.7 0.64 1.08 31.5 25.7 1.4 900 29.7 1.71 23.9 100.6 5.10 3.1 900 28.6 19.9 0.69 1.14 32.5 25.0 1.5 70 4.0 1.3 3.0 700 30.5 1.76 24.5 110.4 5.07 3.5 700 27.6 17.9 0.65 1.28 31.9 21.5 2.0 900 31.4 1.76 25.4 102.3 5.24 3.3 900 28.4 20.1 0.71 1.35 33.0 21.0 2.1 6.0 2.7 6.2 700 31.5 1.79 25.4 111.7 5.16 3.6 700 27.6 17.9 0.65 1.23 31.9 22.4 1.8 900 32.5 1.77 26.5 103.4 5.38 3.4 900 28.5 20.1 0.70 1.30 32.9 21.9 2.0 8.0 4.5 10.4 700 32.1 1.81 25.9 112.5 5.19 3.7 700 27.9 17.9 0.64 1.21 32.1 23.1 1.7 900 33.1 1.79 27.0 104.0 5.41 3.4 900 28.8 20.1 0.70 1.27 33.1 22.6 1.9 80 4.0 1.3 2.9 700 33.0 1.84 26.7 113.6 5.24 4.0 700 26.4 17.7 0.67 1.43 31.3 18.4 2.4 900 34.0 1.82 27.8 105.0 5.49 3.7 900 27.2 19.8 0.73 1.50 32.4 18.1 2.6 6.0 2.6 5.9 700 34.2 1.87 27.8 115.2 5.35 4.1 700 26.5 17.7 0.67 1.38 31.2 19.2 2.3 900 35.3 1.84 29.0 106.3 5.62 3.8 900 27.4 19.8 0.72 1.44 32.3 19.0 2.5 8.0 4.3 10.0 700 34.7 1.90 28.2 115.9 5.35 4.2 700 26.8 17.7 0.66 1.35 31.4 19.9 2.1 900 35.9 1.86 29.5 106.9 5.65 3.9 900 27.6 19.9 0.72 1.42 32.5 19.5 2.4 90 4.0 1.2 2.8 700 35.5 1.94 28.9 117.0 5.35 4.4 700 24.4 16.7 0.68 1.60 29.9 15.3 3.0 900 36.8 1.90 30.3 107.8 5.67 4.1 900 25.2 18.7 0.74 1.66 30.9 15.2 3.2 6.0 2.5 5.7 700 36.9 1.97 30.1 118.8 5.47 4.6 700 24.6 16.7 0.68 1.54 29.8 16.0 2.8 900 38.2 1.93 31.6 109.3 5.80 4.2 900 25.4 18.7 0.74 1.60 30.8 15.9 3.1 8.0 4.2 9.6 700 37.3 2.00 30.5 119.4 5.46 4.7 700 24.8 16.8 0.68 1.50 30.0 16.5 2.6 900 38.8 1.95 32.1 109.9 5.82 4.4 900 25.6 18.8 0.73 1.57 31.0 16.3 2.9 100 4.0 1.2 2.7 Operation not recommended Operation not recommended 6.0 2.4 5.5 700 23.5 16.7 0.71 1.73 29.4 13.5 3.5 900 24.2 18.7 0.77 1.79 30.3 13.5 3.8 8.0 4.0 9.3 700 23.7 16.8 0.71 1.70 29.5 14.0 3.3 900 24.4 18.8 0.77 1.76 30.4 13.9 3.6 110 4.0 1.1 2.6 Operation not recommended 6.0 2.3 5.3 700 20.0 15.7 0.79 1.94 26.6 10.3 4.3 900 20.6 17.5 0.85 1.99 27.4 10.3 4.6 8.0 3.9 8.9 700 20.1 15.8 0.78 1.89 26.6 10.6 4.0 900 20.8 17.6 0.84 1.95 27.5 10.7 4.4 120 4.0 1.1 2.5 Operation not recommended 6.0 2.2 5.1 700 19.4 15.2 0.78 2.18 26.8 8.9 5.1 900 19.9 16.9 0.85 2.24 27.6 8.9 5.6 8.0 3.7 8.6 700 19.5 15.3 0.78 2.13 26.7 9.1 4.8 900 20.2 16.9 0.84 2.18 27.6 9.2 5.3 Multiple Flow Rates (for EWT) are shown in the table above. The lowest flow rate shown is used for geothermal open loop/well water systems with a minimum 50° F. The second flow rate shown is the minimum geothermal closed loop flow rate. The third flow rate shown is optimum for geothermal closed loop and the suggested flow rate for boiler tower applications. 27 5 SERIES 500R11 SPECIFICATION CATALOG NSZ036 - Performance Data NSZ036 - Single Speed (1250 cfm) EWT °F Flow GPM WPD HEATING - EAT 70°F COOLING - EAT 80/67 °F PSI FT Airflow CFM HC kBtuh Power kW HE kBtuh LAT °F COP HWC kBtuh Airflow CFM TC kBtuh SC kBtuh S/T Ratio Power kW HR kBtuh EER HWC kBtuh 20 5.0 1.0 2.4 Operation not recommended Operation not recommended7.0 2.1 4.9 9.0 3.6 8.2 1050 20.5 1.81 14.3 88.0 3.31 2.6 1250 20.8 1.85 14.5 85.4 3.30 2.4 30 5.0 1.0 2.3 Operation not recommended Operation not recommended 7.0 2.1 4.7 1050 23.1 1.83 16.8 90.4 3.69 2.8 1050 27.3 17.6 0.65 1.02 30.7 26.7 - 1250 23.6 1.87 17.2 87.5 3.70 2.6 1250 28.0 19.7 0.70 1.10 31.8 25.4 - 9.0 3.5 8.0 1050 23.7 1.85 17.4 90.9 3.75 2.9 1050 27.5 17.6 0.64 1.00 30.9 27.5 - 1250 24.1 1.89 17.7 87.9 3.74 2.6 1250 28.5 19.7 0.69 1.06 32.1 26.8 - 40 5.0 1.0 2.3 Operation not recommended Operation not recommended 7.0 2.0 4.6 1050 27.3 1.89 20.9 94.1 4.24 3.2 1050 29.9 19.6 0.66 1.12 33.7 26.7 - 1250 28.0 1.92 21.4 90.7 4.28 2.9 1250 30.7 21.9 0.71 1.20 34.8 25.6 - 9.0 3.4 7.8 1050 28.0 1.91 21.5 94.7 4.29 3.2 1050 30.1 19.5 0.65 1.10 33.9 27.5 - 1250 28.6 1.94 22.0 91.2 4.33 3.0 1250 31.2 21.9 0.70 1.16 35.1 26.8 - 50 5.0 1.0 2.2 1050 29.2 1.92 22.7 95.8 4.47 3.4 1050 32.2 21.1 0.66 1.29 36.6 25.0 1.5 1250 29.9 1.93 23.3 92.1 4.53 3.2 1250 33.2 23.8 0.72 1.37 37.8 24.2 1.6 7.0 1.9 4.5 1050 30.2 1.93 23.6 96.6 4.59 3.5 1050 32.3 21.3 0.66 1.24 36.5 26.1 1.4 1250 30.9 1.94 24.3 92.9 4.67 3.2 1250 33.2 23.9 0.72 1.32 37.7 25.2 1.5 9.0 3.3 7.5 1050 30.8 1.95 24.2 97.2 4.63 3.6 1050 32.6 21.3 0.65 1.21 36.7 26.9 1.3 1250 31.6 1.96 24.9 93.4 4.73 3.3 1250 33.6 23.9 0.71 1.29 38.0 26.2 1.5 60 5.0 0.9 2.1 1050 33.4 1.99 26.6 99.5 4.92 3.8 1050 31.9 21.6 0.68 1.40 36.7 22.8 1.8 1250 34.3 2.00 27.5 95.4 5.04 3.6 1250 32.9 24.3 0.74 1.49 38.0 22.1 1.9 7.0 1.9 4.3 1050 34.6 2.01 27.7 100.5 5.03 4.0 1050 32.0 21.8 0.68 1.35 36.6 23.7 1.7 1250 35.5 2.01 28.7 96.3 5.18 3.7 1250 33.0 24.4 0.74 1.43 37.9 23.1 1.9 9.0 3.1 7.3 1050 35.2 2.04 28.3 101.1 5.07 4.1 1050 32.4 21.8 0.67 1.32 36.9 24.5 1.6 1250 36.2 2.03 29.3 96.8 5.23 3.7 1250 33.4 24.4 0.73 1.40 38.1 23.9 1.8 70 5.0 0.9 2.1 1050 36.4 2.03 29.5 102.1 5.25 4.3 1050 32.4 22.5 0.69 1.55 37.7 20.8 2.3 1250 37.5 2.02 30.6 97.7 5.43 4.0 1250 33.4 25.3 0.76 1.64 39.0 20.3 2.4 7.0 1.8 4.2 1050 37.6 2.06 30.6 103.2 5.34 4.5 1050 32.5 22.6 0.70 1.50 37.6 21.7 2.1 1250 38.8 2.04 31.8 98.7 5.57 4.1 1250 33.5 25.3 0.75 1.58 38.8 21.2 2.3 9.0 3.0 7.0 1050 38.3 2.09 31.2 103.8 5.38 4.6 1050 32.8 22.6 0.69 1.47 37.8 22.4 2.0 1250 39.5 2.06 32.4 99.2 5.60 4.2 1250 33.8 25.4 0.75 1.55 39.1 21.9 2.2 80 5.0 0.9 2.0 1050 40.2 2.11 33.0 105.4 5.57 4.8 1050 31.6 22.4 0.71 1.73 37.5 18.3 2.8 1250 41.5 2.09 34.4 100.7 5.83 4.5 1250 32.6 25.1 0.77 1.81 38.7 18.0 3.0 7.0 1.7 4.0 1050 41.6 2.15 34.3 106.7 5.68 5.0 1050 31.7 22.5 0.71 1.66 37.4 19.1 2.6 1250 43.0 2.11 35.8 101.9 5.97 4.6 1250 32.7 25.1 0.77 1.74 38.6 18.8 2.9 9.0 2.9 6.8 1050 42.3 2.18 34.8 107.3 5.69 5.1 1050 32.0 22.5 0.70 1.63 37.6 19.7 2.5 1250 43.7 2.14 36.4 102.4 6.00 4.7 1250 33.0 25.2 0.76 1.71 38.8 19.4 2.7 90 5.0 0.8 1.9 1050 42.5 2.16 35.1 107.4 5.76 5.4 1050 29.6 21.8 0.74 2.05 36.6 14.4 3.5 1250 44.0 2.11 36.8 102.6 6.10 5.0 1250 30.5 24.4 0.80 2.14 37.8 14.3 3.7 7.0 1.7 3.9 1050 44.1 2.19 36.6 108.9 5.89 5.6 1050 29.8 21.8 0.73 1.97 36.5 15.1 3.3 1250 45.7 2.14 38.4 103.8 6.24 5.2 1250 30.7 24.4 0.79 2.05 37.7 15.0 3.6 9.0 2.8 6.6 1050 44.6 2.23 37.0 109.4 5.87 5.8 1050 30.1 21.9 0.73 1.93 36.7 15.6 3.1 1250 46.3 2.17 38.9 104.3 6.26 5.3 1250 31.0 24.5 0.79 2.02 37.9 15.4 3.4 100 5.0 0.8 1.8 Operation not recommended Operation not recommended 7.0 1.6 3.8 1050 29.0 21.7 0.75 2.06 36.0 14.1 4.1 1250 29.9 24.2 0.81 2.13 37.1 14.0 4.4 9.0 2.7 6.3 1050 29.2 21.8 0.75 2.01 36.1 14.5 3.8 1250 30.2 24.3 0.81 2.08 37.3 14.5 4.2 110 5.0 0.8 1.8 Operation not recommended 7.0 1.6 3.6 1050 26.1 20.2 0.77 2.27 33.9 11.5 5.0 1250 26.9 22.5 0.84 2.34 34.9 11.5 5.4 9.0 2.6 6.1 1050 26.3 20.3 0.77 2.22 33.9 11.8 4.6 1250 27.2 22.6 0.83 2.29 35.0 11.9 5.1 120 5.0 0.7 1.7 Operation not recommended 7.0 1.5 3.5 1050 24.5 19.9 0.81 2.55 33.2 9.6 6.0 1250 25.2 22.1 0.88 2.61 34.1 9.6 6.5 9.0 2.5 5.8 1050 24.6 20.0 0.81 2.49 33.1 9.9 5.5 1250 25.5 22.2 0.87 2.55 34.2 10.0 6.2 Multiple Flow Rates (for EWT) are shown in the table above. The lowest flow rate shown is used for geothermal open loop/well water systems with a minimum 50° F. The second flow rate shown is the minimum geothermal closed loop flow rate. The third flow rate shown is optimum for geothermal closed loop and the suggested flow rate for boiler tower applications. 28 5 SERIES 500R11 SPECIFICATION CATALOG NSZ042 - Performance Data NSZ042 - Single Speed (1350 cfm) EWT °F Flow GPM WPD HEATING - EAT 70°F COOLING - EAT 80/67 °F PSI FT Airflow CFM HC kBtuh Power kW HE kBtuh LAT °F COP HWC kBtuh Airflow CFM TC kBtuh SC kBtuh S/T Ratio Power kW HR kBtuh EER HWC kBtuh 20 5.0 0.8 1.9 Operation not recommended Operation not recommended8.0 2.3 5.3 11.0 4.4 10.3 1150 23.3 2.15 16.0 88.8 3.18 3.9 1350 23.6 2.13 16.3 86.2 3.25 3.6 30 5.0 0.8 1.8 Operation not recommended Operation not recommended 8.0 2.2 5.1 1150 27.1 2.19 19.7 91.8 3.63 4.2 1150 37.5 23.3 0.62 1.37 42.2 27.3 - 1350 27.4 2.17 20.0 88.8 3.71 3.8 1350 39.3 26.2 0.67 1.45 44.3 27.0 - 11.0 4.3 10.0 1150 27.5 2.19 20.0 92.1 3.68 4.3 1150 37.9 23.3 0.62 1.33 42.5 28.4 - 1350 27.8 2.17 20.4 89.1 3.76 3.9 1350 39.7 26.2 0.66 1.41 44.5 28.1 - 40 5.0 0.8 1.8 Operation not recommended Operation not recommended 8.0 2.1 4.9 1150 30.9 2.28 23.1 94.9 3.97 4.6 1150 39.1 24.9 0.64 1.46 44.1 26.8 - 1350 31.3 2.24 23.7 91.5 4.10 4.2 1350 40.9 28.0 0.68 1.54 46.1 26.5 - 11.0 4.2 9.7 1150 31.4 2.29 23.6 95.3 4.03 4.7 1150 39.5 24.9 0.63 1.42 44.4 27.8 - 1350 31.9 2.25 24.2 91.9 4.16 4.3 1350 41.3 28.0 0.68 1.50 46.4 27.5 - 50 5.0 0.7 1.7 1150 33.2 2.29 25.4 96.7 4.25 5.0 1150 39.8 25.7 0.65 1.66 45.5 24.0 2.3 1350 33.8 2.24 26.1 93.2 4.41 4.6 1350 41.5 28.9 0.70 1.74 47.4 23.8 2.4 8.0 2.1 4.8 1150 34.6 2.34 26.6 97.8 4.32 5.1 1150 40.2 26.0 0.65 1.58 45.6 25.5 2.2 1350 35.2 2.29 27.4 94.1 4.50 4.7 1350 41.9 29.2 0.70 1.66 47.6 25.2 2.3 11.0 4.1 9.4 1150 35.3 2.36 27.2 98.4 4.38 5.3 1150 40.6 26.0 0.64 1.53 45.9 26.5 2.0 1350 35.9 2.30 28.1 94.6 4.57 4.8 1350 42.3 29.2 0.69 1.61 47.8 26.2 2.2 60 5.0 0.7 1.7 1150 36.4 2.36 28.4 99.3 4.53 5.6 1150 39.7 26.4 0.66 1.82 45.9 21.8 2.8 1350 37.1 2.29 29.3 95.5 4.74 5.1 1350 41.2 29.6 0.72 1.91 47.7 21.6 3.0 8.0 2.0 4.6 1150 38.0 2.43 29.8 100.6 4.59 5.7 1150 40.2 26.6 0.66 1.73 46.1 23.2 2.6 1350 38.9 2.35 30.8 96.6 4.84 5.3 1350 41.7 29.9 0.72 1.82 47.9 22.9 2.8 11.0 3.9 9.1 1150 38.9 2.45 30.6 101.4 4.66 5.9 1150 40.6 26.6 0.66 1.68 46.3 24.1 2.4 1350 39.8 2.37 31.7 97.3 4.92 5.4 1350 42.2 29.9 0.71 1.77 48.2 23.9 2.7 70 5.0 0.7 1.6 1150 39.5 2.43 31.2 101.8 4.76 6.2 1150 39.8 27.2 0.68 2.01 46.7 19.8 3.5 1350 40.4 2.35 32.4 97.7 5.03 5.8 1350 41.3 30.6 0.74 2.11 48.5 19.6 3.7 8.0 1.9 4.5 1150 41.4 2.52 32.8 103.3 4.82 6.4 1150 40.4 27.5 0.68 1.91 47.0 21.1 3.3 1350 42.4 2.43 34.1 99.1 5.12 5.9 1350 41.9 30.9 0.74 2.00 48.7 20.9 3.6 11.0 3.8 8.8 1150 42.5 2.55 33.8 104.2 4.89 6.6 1150 40.8 27.5 0.67 1.86 47.2 22.0 3.1 1350 43.6 2.45 35.2 99.9 5.21 6.1 1350 42.3 30.9 0.73 1.94 49.0 21.8 3.4 80 5.0 0.7 1.6 1150 42.5 2.47 34.0 104.2 5.03 7.0 1150 38.3 26.6 0.69 2.24 46.0 17.1 4.5 1350 43.6 2.37 35.5 99.9 5.38 6.5 1350 39.6 29.9 0.75 2.34 47.6 16.9 4.7 8.0 1.9 4.3 1150 44.7 2.57 35.9 106.0 5.09 7.2 1150 39.0 26.9 0.69 2.12 46.3 18.4 4.2 1350 45.9 2.46 37.5 101.5 5.47 6.7 1350 40.3 30.2 0.75 2.22 47.9 18.2 4.5 11.0 3.7 8.5 1150 45.9 2.61 37.0 107.0 5.16 7.5 1150 39.4 26.9 0.68 2.06 46.5 19.1 3.9 1350 47.3 2.49 38.8 102.4 5.56 6.9 1350 40.7 30.2 0.74 2.15 48.1 18.9 4.3 90 5.0 0.7 1.5 1150 45.3 2.52 36.7 106.5 5.27 7.9 1150 36.3 25.8 0.71 2.50 44.8 14.5 5.6 1350 46.6 2.40 38.4 102.0 5.69 7.3 1350 37.4 29.0 0.78 2.61 46.3 14.3 5.9 8.0 1.8 4.2 1150 47.8 2.64 38.8 108.5 5.31 8.1 1150 37.0 26.1 0.70 2.37 45.1 15.7 5.2 1350 49.3 2.50 40.8 103.8 5.77 7.5 1350 38.2 29.3 0.77 2.46 46.6 15.5 5.7 11.0 3.5 8.2 1150 49.3 2.68 40.1 109.7 5.38 8.4 1150 37.4 26.1 0.70 2.30 45.3 16.3 4.8 1350 50.9 2.54 42.2 104.9 5.87 7.8 1350 38.6 29.3 0.76 2.39 46.7 16.1 5.4 100 5.0 0.6 1.5 Operation not recommended Operation not recommended 8.0 1.7 4.0 1150 35.6 25.6 0.72 2.64 44.6 13.5 6.5 1350 36.7 28.7 0.78 2.74 46.0 13.4 7.0 11.0 3.4 7.9 1150 36.0 25.6 0.71 2.56 44.7 14.1 6.0 1350 37.0 28.7 0.78 2.66 46.1 13.9 6.7 110 5.0 0.6 1.4 Operation not recommended 8.0 1.7 3.9 1150 32.5 23.7 0.73 2.94 42.5 11.1 7.9 1350 33.3 26.6 0.80 3.05 43.7 10.9 8.6 11.0 3.3 7.6 1150 32.8 23.7 0.72 2.86 42.6 11.5 7.4 1350 33.7 26.6 0.79 2.96 43.8 11.4 8.2 120 5.0 0.6 1.3 Operation not recommended 8.0 1.6 3.7 1150 30.6 23.4 0.76 3.27 41.8 9.4 9.6 1350 31.3 26.3 0.84 3.38 42.9 9.3 10.4 11.0 3.2 7.3 1150 30.9 23.4 0.76 3.18 41.8 9.7 8.9 1350 31.7 26.3 0.83 3.28 42.9 9.6 9.9 Multiple Flow Rates (for EWT) are shown in the table above. The lowest flow rate shown is used for geothermal open loop/well water systems with a minimum 50° F. The second flow rate shown is the minimum geothermal closed loop flow rate. The third flow rate shown is optimum for geothermal closed loop and the suggested flow rate for boiler tower applications. 29 5 SERIES 500R11 SPECIFICATION CATALOG NSZ048 - Performance Data NSZ048 - Single Speed (1500 cfm) EWT °F Flow GPM WPD HEATING - EAT 70°F COOLING - EAT 80/67 °F PSI FT Airflow CFM HC kBtuh Power kW HE kBtuh LAT °F COP HWC kBtuh Airflow CFM TC kBtuh SC kBtuh S/T Ratio Power kW HR kBtuh EER HWC kBtuh 20 6.0 1.1 2.6 Operation not recommended Operation not recommended9.0 2.3 5.4 12.0 4.0 9.2 1300 29.9 2.76 20.5 91.3 3.18 5.1 1500 30.3 2.73 20.9 88.7 3.24 4.6 30 6.0 1.1 2.5 Operation not recommended Operation not recommended 9.0 2.3 5.3 1300 34.3 2.84 24.6 94.4 3.54 5.3 1300 44.7 28.0 0.63 1.62 50.2 27.6 - 1500 34.7 2.81 25.1 91.4 3.61 4.9 1500 46.8 31.4 0.67 1.71 52.6 27.3 - 12.0 3.9 9.0 1300 34.8 2.84 25.1 94.8 3.59 5.5 1300 45.1 28.0 0.62 1.57 50.5 28.7 - 1500 35.2 2.81 25.6 91.7 3.67 5.0 1500 47.3 31.4 0.66 1.66 52.9 28.4 - 40 6.0 1.1 2.5 Operation not recommended Operation not recommended 9.0 2.2 5.1 1300 39.4 2.96 29.3 98.1 3.90 5.9 1300 46.4 29.5 0.64 1.78 52.5 26.1 - 1500 40.0 2.91 30.0 94.7 4.02 5.4 1500 48.5 33.2 0.68 1.88 54.9 25.8 - 12.0 3.8 8.7 1300 40.1 2.97 30.0 98.6 3.95 6.1 1300 46.9 29.5 0.63 1.73 52.8 27.2 - 1500 40.7 2.92 30.7 95.1 4.08 5.5 1500 49.0 33.2 0.68 1.82 55.2 26.9 - 50 6.0 1.0 2.4 1300 42.3 3.00 32.0 100.1 4.13 6.4 1300 47.4 30.7 0.65 2.07 54.5 22.9 2.7 1500 42.9 2.93 32.9 96.5 4.29 5.9 1500 49.4 34.4 0.70 2.18 56.8 22.7 2.8 9.0 2.1 4.9 1300 44.0 3.07 33.5 101.3 4.20 6.6 1300 47.9 31.0 0.65 1.97 54.6 24.3 2.5 1500 44.7 3.00 34.5 97.6 4.37 6.0 1500 49.9 34.8 0.70 2.08 57.0 24.0 2.7 12.0 3.7 8.4 1300 44.9 3.09 34.3 101.9 4.26 6.8 1300 48.4 31.0 0.64 1.92 54.9 25.3 2.3 1500 45.6 3.01 35.4 98.2 4.44 6.2 1500 50.4 34.8 0.69 2.02 57.3 25.0 2.6 60 6.0 1.0 2.3 1300 46.5 3.09 35.9 103.1 4.41 7.1 1300 46.3 30.3 0.65 2.30 54.1 20.2 3.3 1500 47.3 3.01 37.1 99.2 4.61 6.6 1500 48.1 34.0 0.71 2.41 56.3 19.9 3.5 9.0 2.1 4.8 1300 48.5 3.18 37.7 104.6 4.47 7.4 1300 46.9 30.6 0.65 2.19 54.3 21.5 3.0 1500 49.5 3.08 39.0 100.6 4.70 6.8 1500 48.7 34.4 0.71 2.29 56.5 21.2 3.3 12.0 3.5 8.2 1300 49.6 3.21 38.7 105.4 4.53 7.6 1300 47.4 30.6 0.65 2.12 54.6 22.3 2.8 1500 50.7 3.11 40.1 101.3 4.78 7.0 1500 49.2 34.4 0.70 2.23 56.8 22.1 3.1 70 6.0 1.0 2.2 1300 50.7 3.19 39.8 106.1 4.66 8.0 1300 46.1 30.6 0.66 2.57 54.9 17.9 4.1 1500 51.8 3.08 41.3 102.0 4.92 7.4 1500 47.8 34.4 0.72 2.69 57.0 17.7 4.3 9.0 2.0 4.6 1300 53.1 3.30 41.8 107.8 4.72 8.3 1300 46.8 31.0 0.66 2.44 55.1 19.2 3.8 1500 54.3 3.18 43.5 103.5 5.01 7.6 1500 48.5 34.8 0.72 2.56 57.2 19.0 4.1 12.0 3.4 7.9 1300 54.5 3.34 43.1 108.8 4.78 8.5 1300 47.3 31.0 0.65 2.37 55.4 19.9 3.5 1500 55.8 3.21 44.8 104.4 5.09 7.9 1500 49.0 34.8 0.71 2.48 57.5 19.7 3.9 80 6.0 0.9 2.1 1300 54.0 3.27 42.9 108.5 4.85 9.0 1300 44.2 30.0 0.68 2.88 54.0 15.3 5.2 1500 55.4 3.14 44.7 104.2 5.18 8.4 1500 45.7 33.7 0.74 3.01 55.9 15.2 5.5 9.0 1.9 4.5 1300 56.8 3.40 45.2 110.5 4.90 9.3 1300 45.0 30.3 0.67 2.73 54.3 16.5 4.8 1500 58.4 3.25 47.3 106.0 5.26 8.6 1500 46.5 34.0 0.73 2.85 56.2 16.3 5.2 12.0 3.3 7.6 1300 58.5 3.45 46.7 111.6 4.97 9.6 1300 45.4 30.3 0.67 2.65 54.5 17.1 4.5 1500 60.1 3.29 48.9 107.1 5.35 8.9 1500 47.0 34.0 0.72 2.77 56.4 17.0 5.0 90 6.0 0.9 2.1 1300 57.4 3.35 46.0 110.9 5.02 10.2 1300 41.2 28.6 0.69 3.22 52.2 12.8 6.5 1500 59.1 3.19 48.2 106.5 5.42 9.4 1500 42.5 32.1 0.76 3.35 53.9 12.7 6.9 9.0 1.9 4.3 1300 60.6 3.51 48.6 113.2 5.07 10.5 1300 42.1 28.9 0.69 3.04 52.5 13.8 6.0 1500 62.4 3.33 51.1 108.5 5.50 9.7 1500 43.4 32.4 0.75 3.17 54.2 13.7 6.6 12.0 3.2 7.4 1300 62.5 3.57 50.3 114.5 5.14 10.8 1300 42.5 28.9 0.68 2.95 52.6 14.4 5.6 1500 64.4 3.38 52.9 109.8 5.59 10.0 1500 43.8 32.4 0.74 3.08 54.3 14.2 6.2 100 6.0 0.9 2.0 Operation not recommended Operation not recommended 9.0 1.8 4.2 1300 40.6 28.5 0.70 3.41 52.3 11.9 7.5 1500 41.8 32.0 0.77 3.54 53.9 11.8 8.1 12.0 3.1 7.1 1300 41.0 28.5 0.69 3.31 52.3 12.4 7.0 1500 42.2 32.0 0.76 3.44 53.9 12.3 7.7 110 6.0 0.8 1.9 Operation not recommended 9.0 1.7 4.0 1300 36.7 26.4 0.72 3.80 49.7 9.7 9.2 1500 37.7 29.7 0.79 3.93 51.1 9.6 10.0 12.0 3.0 6.8 1300 37.1 26.4 0.71 3.69 49.7 10.1 8.5 1500 38.1 29.7 0.78 3.82 51.1 10.0 9.5 120 6.0 0.8 1.8 Operation not recommended 9.0 1.7 3.8 1300 34.8 25.9 0.74 4.24 49.2 8.2 11.1 1500 35.6 29.1 0.82 4.38 50.5 8.1 12.0 12.0 2.8 6.6 1300 35.1 25.9 0.74 4.11 49.2 8.5 10.3 1500 36.0 29.1 0.81 4.25 50.5 8.5 11.5 Multiple Flow Rates (for EWT) are shown in the table above. The lowest flow rate shown is used for geothermal open loop/well water systems with a minimum 50° F. The second flow rate shown is the minimum geothermal closed loop flow rate. The third flow rate shown is optimum for geothermal closed loop and the suggested flow rate for boiler tower applications. 30 5 SERIES 500R11 SPECIFICATION CATALOG NSZ060 - Performance Data NSZ060 - Single Speed (2000 cfm) EWT °F Flow GPM WPD HEATING - EAT 70°F COOLING - EAT 80/67 °F PSI FT Airflow CFM HC kBtuh Power kW HE kBtuh LAT °F COP HWC kBtuh Airflow CFM TC kBtuh SC kBtuh S/T Ratio Power kW HR kBtuh EER HWC kBtuh 20 9.0 2.5 5.7 Operation not recommended Operation not recommended12.0 4.0 9.2 15.0 5.9 13.5 1500 36.4 3.64 24.0 92.5 2.93 6.2 2000 37.1 3.71 24.5 87.2 2.93 5.7 30 9.0 2.4 5.5 Operation not recommended Operation not recommended 12.0 3.9 8.9 1500 41.0 3.65 28.6 95.3 3.30 6.7 1500 64.1 42.0 0.66 2.10 71.3 30.5 - 2000 41.9 3.71 29.2 89.4 3.30 6.1 2000 62.1 43.3 0.70 2.54 70.8 24.4 - 15.0 5.7 13.1 1500 42.3 3.74 29.6 96.1 3.32 6.9 1500 64.8 42.1 0.65 2.10 72.0 30.8 - 2000 43.2 3.81 30.2 90.0 3.32 6.3 2000 63.1 42.8 0.68 2.38 71.2 26.6 - 40 9.0 2.3 5.3 Operation not recommended Operation not recommended 12.0 3.7 8.7 1500 50.3 3.82 37.3 101.1 3.86 7.4 1500 73.4 47.4 0.65 2.40 81.6 30.6 - 2000 51.5 3.90 38.2 93.8 3.87 6.8 2000 72.7 49.5 0.68 2.81 82.3 25.9 - 15.0 5.5 12.7 1500 51.7 3.91 38.4 101.9 3.88 7.6 1500 74.1 47.6 0.64 2.39 82.3 31.0 - 2000 52.7 3.97 39.2 94.4 3.89 6.9 2000 73.6 49.3 0.67 2.65 82.6 27.7 - 50 9.0 2.2 5.2 1500 54.1 3.96 40.6 103.4 4.00 8.0 1500 64.2 43.4 0.68 2.74 73.5 23.4 3.4 2000 54.6 4.01 41.0 95.3 4.00 7.4 2000 64.4 45.0 0.70 3.06 74.8 21.0 3.6 12.0 3.6 8.4 1500 54.6 3.95 41.2 103.7 4.05 8.2 1500 64.3 43.5 0.68 2.64 73.3 24.4 3.2 2000 56.1 4.05 42.3 96.0 4.06 7.6 2000 64.4 45.5 0.71 3.00 74.6 21.4 3.4 15.0 5.3 12.3 1500 56.0 4.03 42.3 104.6 4.07 8.5 1500 64.9 43.7 0.67 2.62 73.9 24.8 2.9 2000 57.1 4.09 43.1 96.4 4.09 7.7 2000 65.0 45.5 0.70 2.86 74.8 22.7 3.3 60 9.0 2.2 5.0 1500 62.1 4.10 48.1 108.3 4.44 8.9 1500 69.9 46.2 0.66 3.04 80.3 23.0 4.1 2000 63.1 4.13 49.0 99.2 4.48 8.3 2000 71.5 49.1 0.69 3.33 82.9 21.4 4.4 12.0 3.5 8.1 1500 63.6 4.11 49.5 109.3 4.53 9.2 1500 70.1 46.4 0.66 2.93 80.1 23.9 3.8 2000 64.5 4.17 50.3 99.9 4.53 8.5 2000 71.8 49.3 0.69 3.24 82.9 22.2 4.2 15.0 5.2 11.9 1500 65.0 4.19 50.7 110.1 4.55 9.5 1500 70.8 46.7 0.66 2.91 80.7 24.4 3.6 2000 66.3 4.24 51.9 100.7 4.59 8.7 2000 72.2 49.6 0.69 3.12 82.8 23.2 4.0 70 9.0 2.1 4.9 1500 65.4 4.26 50.9 110.4 4.50 10.1 1500 58.6 40.5 0.69 3.32 69.9 17.6 5.2 2000 66.8 4.28 52.2 100.9 4.58 9.3 2000 61.2 44.0 0.72 3.58 73.4 17.1 5.5 12.0 3.4 7.9 1500 67.7 4.30 53.1 111.8 4.62 10.4 1500 58.9 40.8 0.69 3.20 69.8 18.4 4.8 2000 68.1 4.32 53.3 101.5 4.61 9.6 2000 61.8 44.0 0.71 3.44 73.5 17.9 5.2 15.0 5.0 11.6 1500 69.0 4.37 54.1 112.6 4.63 10.7 1500 59.4 41.1 0.69 3.16 70.2 18.8 4.5 2000 70.6 4.41 55.5 102.7 4.69 9.8 2000 61.8 44.5 0.72 3.34 73.2 18.5 5.0 80 9.0 2.0 4.7 1500 72.9 4.36 58.0 115.0 4.90 11.3 1500 65.4 44.6 0.68 3.81 78.4 17.2 6.5 2000 74.2 4.37 59.3 104.4 4.98 10.5 2000 67.1 47.7 0.71 4.06 80.9 16.5 6.9 12.0 3.3 7.6 1500 76.2 4.44 61.0 117.0 5.03 11.7 1500 65.8 45.0 0.68 3.66 78.2 18.0 6.1 2000 76.8 4.39 61.8 105.6 5.13 10.8 2000 67.8 47.7 0.70 3.87 81.0 17.5 6.6 15.0 4.8 11.2 1500 77.4 4.49 62.0 117.8 5.05 12.0 1500 66.4 45.4 0.68 3.60 78.7 18.4 5.7 2000 78.9 4.53 63.5 106.5 5.11 11.1 2000 68.1 48.2 0.71 3.76 80.9 18.1 6.3 90 9.0 2.0 4.5 1500 75.0 4.52 59.5 116.3 4.86 12.7 1500 54.1 38.8 0.72 4.08 68.0 13.3 8.2 2000 76.2 4.52 60.8 105.3 4.94 11.8 2000 54.5 40.8 0.75 4.32 69.3 12.6 8.7 12.0 3.2 7.3 1500 78.9 4.63 63.1 118.7 5.00 13.1 1500 54.5 39.1 0.72 3.92 67.9 13.9 7.7 2000 79.9 4.52 64.5 107.0 5.18 12.1 2000 55.1 40.8 0.74 4.09 69.0 13.5 8.3 15.0 4.7 10.8 1500 80.0 4.68 64.0 119.4 5.01 13.5 1500 55.1 39.5 0.72 3.85 68.2 14.3 7.1 2000 81.4 4.71 65.3 107.7 5.07 12.5 2000 55.6 41.2 0.74 3.97 69.2 14.0 7.9 100 9.0 1.9 4.4 Operation not recommended Operation not recommended 12.0 3.1 7.1 1500 60.1 42.9 0.71 4.59 75.7 13.1 9.5 2000 60.7 44.7 0.74 4.70 76.7 12.9 10.3 15.0 4.5 10.4 1500 60.7 43.4 0.72 4.49 76.0 13.5 8.8 2000 61.3 45.2 0.74 4.58 76.9 13.4 9.8 110 9.0 1.8 4.2 Operation not recommended 12.0 2.9 6.8 1500 47.9 35.7 0.75 4.95 64.8 9.7 11.6 2000 48.4 37.2 0.77 5.00 65.4 9.7 12.6 15.0 4.3 10.0 1500 48.4 36.2 0.75 4.82 64.8 10.0 10.8 2000 48.9 37.7 0.77 4.87 65.5 10.0 12.0 120 9.0 1.7 4.0 Operation not recommended 12.0 2.8 6.5 1500 46.1 36.3 0.79 5.62 65.3 8.2 14.1 2000 45.1 37.0 0.82 5.64 64.4 8.0 15.3 15.0 4.2 9.6 1500 46.5 36.8 0.79 5.47 65.2 8.5 13.1 2000 45.9 37.3 0.81 5.47 64.6 8.4 14.5 Multiple Flow Rates (for EWT) are shown in the table above. The lowest flow rate shown is used for geothermal open loop/well water systems with a minimum 50° F. The second flow rate shown is the minimum geothermal closed loop flow rate. The third flow rate shown is optimum for geothermal closed loop and the suggested flow rate for boiler tower applications. 31 5 SERIES 500R11 SPECIFICATION CATALOG NSZ070 - Performance Data NSZ070 - Single Speed (2200 cfm) EWT °F Flow GPM WPD HEATING - EAT 70°F COOLING - EAT 80/67 °F PSI FT Airflow CFM HC kBtuh Power kW HE kBtuh LAT °F COP HWC kBtuh Airflow CFM TC kBtuh SC kBtuh S/T Ratio Power kW HR kBtuh EER HWC kBtuh 20 12.0 3.0 7.0 Operation not recommended Operation not recommended15.0 4.4 10.2 18.0 6.0 13.9 1700 43.8 4.87 27.1 93.8 2.63 7.5 2200 44.8 4.97 27.9 88.9 2.64 6.8 30 12.0 3.0 6.8 Operation not recommended Operation not recommended 15.0 4.3 9.9 1700 50.5 4.98 33.5 97.5 2.97 7.9 1700 58.9 36.9 0.63 2.39 67.1 24.7 - 2200 51.7 5.09 34.3 91.8 2.98 7.3 2200 62.8 42.2 0.67 2.79 72.3 22.5 - 18.0 5.8 13.5 1700 50.7 5.00 33.6 97.6 2.97 8.2 1700 59.3 36.5 0.62 2.38 67.4 24.9 - 2200 51.9 5.11 34.5 91.8 2.98 7.4 2200 63.1 41.7 0.66 2.78 72.6 22.7 - 40 12.0 2.9 6.6 Operation not recommended Operation not recommended 15.0 4.1 9.6 1700 58.9 5.20 41.1 102.1 3.32 8.8 1700 62.2 39.2 0.63 2.63 71.1 23.7 - 2200 60.3 5.26 42.4 95.4 3.36 8.0 2200 66.0 44.8 0.68 3.03 76.3 21.8 - 18.0 5.7 13.1 1700 59.3 5.23 41.4 102.3 3.32 9.0 1700 62.6 39.0 0.62 2.61 71.5 24.0 - 2200 60.7 5.28 42.7 95.6 3.37 8.2 2200 66.5 44.6 0.67 3.01 76.7 22.1 - 50 12.0 2.8 6.4 1700 64.9 5.36 46.6 105.4 3.55 9.5 1700 65.2 41.2 0.63 3.01 75.4 21.6 3.6 2200 66.5 5.38 48.1 98.0 3.62 8.8 2200 68.9 47.1 0.68 3.43 80.6 20.1 3.8 15.0 4.0 9.3 1700 66.2 5.41 47.8 106.1 3.59 9.8 1700 65.5 41.4 0.63 2.92 75.5 22.4 3.4 2200 67.9 5.42 49.4 98.6 3.67 9.0 2200 69.2 47.3 0.68 3.33 80.6 20.8 3.7 18.0 5.5 12.7 1700 66.8 5.45 48.2 106.4 3.59 10.1 1700 66.1 41.6 0.63 2.89 76.0 22.9 3.1 2200 68.5 5.45 49.9 98.8 3.68 9.2 2200 69.9 47.5 0.68 3.29 81.2 21.2 3.5 60 12.0 2.7 6.2 1700 71.9 5.57 52.9 109.2 3.78 10.6 1700 62.7 39.8 0.64 3.31 74.0 18.9 4.4 2200 73.8 5.54 54.9 101.1 3.90 9.8 2200 66.0 45.6 0.69 3.72 78.7 17.7 4.7 15.0 3.9 9.0 1700 74.0 5.65 54.8 110.3 3.84 11.0 1700 62.9 40.0 0.63 3.22 73.9 19.6 4.1 2200 76.0 5.61 56.8 102.0 3.97 10.1 2200 66.3 45.7 0.69 3.62 78.6 18.3 4.5 18.0 5.3 12.3 1700 74.9 5.70 55.5 110.8 3.85 11.3 1700 63.7 40.5 0.64 3.17 74.6 20.1 3.8 2200 76.8 5.64 57.6 102.3 3.99 10.4 2200 67.1 46.3 0.69 3.57 79.3 18.8 4.2 70 12.0 2.6 6.0 1700 79.3 5.80 59.5 113.2 4.01 12.0 1700 62.5 40.4 0.65 3.69 75.1 16.9 5.5 2200 81.4 5.72 61.9 104.3 4.17 11.1 2200 65.5 46.3 0.71 4.11 79.5 15.9 5.9 15.0 3.8 8.7 1700 82.2 5.91 62.1 114.8 4.08 12.3 1700 62.7 40.5 0.65 3.59 74.9 17.5 5.2 2200 84.4 5.81 64.6 105.5 4.26 11.4 2200 65.8 46.3 0.70 3.99 79.4 16.5 5.6 18.0 5.1 11.9 1700 83.4 5.96 63.0 115.4 4.10 12.7 1700 63.6 41.4 0.65 3.53 75.7 18.0 4.8 2200 85.6 5.85 65.7 106.0 4.29 11.7 2200 66.7 47.4 0.71 3.93 80.1 17.0 5.3 80 12.0 2.5 5.8 1700 84.7 6.03 64.2 116.2 4.12 13.4 1700 59.9 38.7 0.65 4.12 73.9 14.5 7.0 2200 87.1 5.88 67.0 106.7 4.34 12.4 2200 62.6 44.3 0.71 4.53 78.0 13.8 7.4 15.0 3.6 8.4 1700 88.6 6.16 67.6 118.3 4.22 13.9 1700 60.1 38.7 0.64 4.00 73.8 15.0 6.5 2200 91.1 6.00 70.7 108.3 4.45 12.8 2200 62.8 44.3 0.71 4.40 77.8 14.3 7.1 18.0 5.0 11.5 1700 90.0 6.22 68.8 119.0 4.24 14.3 1700 61.1 39.9 0.65 3.92 74.5 15.6 6.0 2200 92.7 6.04 72.1 109.0 4.49 13.2 2200 63.9 45.7 0.72 4.31 78.6 14.8 6.7 90 12.0 2.4 5.6 1700 90.5 6.26 69.2 119.3 4.24 15.1 1700 55.0 35.9 0.65 4.57 70.6 12.0 8.8 2200 93.2 6.06 72.5 109.2 4.51 14.0 2200 57.2 41.1 0.72 4.98 74.2 11.5 9.3 15.0 3.5 8.1 1700 95.3 6.43 73.4 121.9 4.35 15.6 1700 55.2 35.8 0.65 4.45 70.3 12.4 8.2 2200 98.2 6.20 77.1 111.3 4.64 14.4 2200 57.4 41.1 0.72 4.84 73.9 11.8 8.9 18.0 4.8 11.1 1700 97.0 6.50 74.8 122.8 4.37 16.0 1700 56.3 37.3 0.66 4.35 71.1 12.9 7.6 2200 100.1 6.26 78.8 112.1 4.69 14.9 2200 58.5 42.7 0.73 4.73 74.7 12.4 8.4 100 12.0 2.3 5.4 Operation not recommended Operation not recommended 15.0 3.4 7.8 1700 53.6 35.4 0.66 5.01 70.7 10.7 10.2 2200 55.5 40.6 0.73 5.39 73.9 10.3 11.0 18.0 4.6 10.7 1700 54.7 37.1 0.68 4.88 71.4 11.2 9.4 2200 56.7 42.6 0.75 5.24 74.6 10.8 10.5 110 12.0 2.2 5.2 Operation not recommended 15.0 3.3 7.5 1700 47.5 31.4 0.66 5.58 66.5 8.5 12.4 2200 49.0 36.1 0.74 5.94 69.3 8.2 13.5 18.0 4.4 10.2 1700 48.7 33.3 0.68 5.41 67.1 9.0 11.6 2200 50.2 38.2 0.76 5.76 69.9 8.7 12.8 120 12.0 2.2 5.0 Operation not recommended 15.0 3.1 7.2 1700 45.1 31.8 0.71 6.27 66.5 7.2 15.0 2200 46.4 36.5 0.79 6.60 68.9 7.0 16.3 18.0 4.3 9.8 1700 46.3 34.0 0.73 6.06 67.0 7.6 14.0 2200 47.6 39.0 0.82 6.38 69.4 7.5 15.5 Multiple Flow Rates (for EWT) are shown in the table above. The lowest flow rate shown is used for geothermal open loop/well water systems with a minimum 50° F. The second flow rate shown is the minimum geothermal closed loop flow rate. The third flow rate shown is optimum for geothermal closed loop and the suggested flow rate for boiler tower applications. 32 5 SERIES 500R11 SPECIFICATION CATALOG NDZ026 - Performance Data NDZ026 - Dual Capacity Low Speed (700 cfm) EWT °F Flow GPM WPD HEATING - EAT 70°F COOLING - EAT 80/67 °F PSI FT Airflow CFM HC kBtuh Power kW HE kBtuh LAT °F COP HWC kBtuh Airflow CFM TC kBtuh SC kBtuh S/T Ratio Power kW HR kBtuh EER HWC kBtuh 20 3.0 0.8 1.9 Operation not recommended Operation not recommended5.0 2.0 4.7 7.0 3.7 8.7 500 11.3 1.10 7.5 90.9 3.01 1.7 700 11.4 1.11 7.7 85.1 3.03 1.5 30 3.0 0.8 1.8 Operation not recommended Operation not recommended 5.0 2.0 4.5 500 13.0 1.11 9.2 94.0 3.42 1.7 500 19.4 12.9 0.66 0.56 21.3 34.8 - 700 13.2 1.12 9.4 87.5 3.46 1.5 700 19.7 14.1 0.71 0.59 21.7 33.5 - 7.0 3.6 8.4 500 13.2 1.12 9.4 94.5 3.46 1.7 500 19.5 12.9 0.66 0.54 21.3 36.0 - 700 13.4 1.13 9.6 87.7 3.48 1.6 700 20.0 14.1 0.70 0.57 21.9 35.1 - 40 3.0 0.8 1.8 Operation not recommended Operation not recommended 5.0 1.9 4.4 500 15.3 1.12 11.5 98.3 4.00 1.7 500 20.1 13.4 0.67 0.61 22.2 32.8 - 700 15.6 1.13 11.8 90.6 4.06 1.6 700 20.5 14.6 0.71 0.64 22.7 31.9 - 7.0 3.5 8.2 500 15.6 1.13 11.7 98.8 4.02 1.8 500 20.3 13.4 0.66 0.59 22.3 34.1 - 700 15.9 1.13 12.0 91.0 4.10 1.6 700 20.7 14.6 0.71 0.62 22.8 33.3 - 50 3.0 0.7 1.7 500 16.5 1.12 12.7 100.6 4.34 1.8 500 20.5 13.8 0.67 0.72 23.0 28.3 0.6 700 16.9 1.12 13.1 92.3 4.42 1.7 700 20.9 15.0 0.72 0.75 23.5 27.8 0.7 5.0 1.8 4.3 500 17.4 1.14 13.5 102.2 4.46 1.8 500 20.7 13.9 0.67 0.69 23.1 30.1 0.6 700 17.7 1.14 13.8 93.4 4.54 1.7 700 21.1 15.2 0.72 0.72 23.6 29.5 0.6 7.0 3.4 7.9 500 17.6 1.16 13.7 102.6 4.46 1.9 500 20.9 13.9 0.66 0.67 23.2 31.4 0.5 700 18.0 1.15 14.1 93.9 4.60 1.7 700 21.4 15.2 0.71 0.70 23.7 30.7 0.6 60 3.0 0.7 1.7 500 18.7 1.14 14.8 104.6 4.82 1.9 500 19.8 13.5 0.68 0.82 22.6 24.3 0.9 700 19.1 1.12 15.3 95.3 4.98 1.8 700 20.2 14.7 0.73 0.85 23.1 23.8 0.9 5.0 1.8 4.1 500 19.6 1.16 15.6 106.3 4.95 2.0 500 20.0 13.7 0.68 0.77 22.7 25.9 0.8 700 20.1 1.15 16.1 96.6 5.11 1.8 700 20.5 14.9 0.73 0.81 23.2 25.4 0.9 7.0 3.3 7.6 500 19.9 1.18 15.9 106.9 4.96 2.1 500 20.2 13.7 0.67 0.75 22.8 26.9 0.7 700 20.4 1.16 16.5 97.0 5.16 1.9 700 20.6 14.9 0.72 0.78 23.3 26.4 0.8 70 3.0 0.7 1.6 500 21.0 1.15 17.0 108.8 5.34 2.2 500 19.8 13.7 0.69 0.93 23.0 21.3 1.2 700 21.5 1.13 17.6 98.4 5.58 2.0 700 20.2 14.9 0.74 0.97 23.5 20.9 1.2 5.0 1.7 4.0 500 21.9 1.17 17.9 110.5 5.47 2.2 500 20.0 13.8 0.69 0.88 23.0 22.7 1.1 700 22.6 1.16 18.6 99.8 5.71 2.1 700 20.5 15.1 0.74 0.92 23.6 22.3 1.2 7.0 3.2 7.4 500 22.3 1.19 18.3 111.3 5.50 2.3 500 20.2 13.8 0.68 0.86 23.2 23.5 1.0 700 22.9 1.17 18.9 100.3 5.76 2.1 700 20.6 15.1 0.73 0.89 23.7 23.2 1.1 80 3.0 0.7 1.6 500 22.8 1.18 18.7 112.2 5.65 2.4 500 18.7 13.2 0.71 1.07 22.4 17.5 1.6 700 23.4 1.15 19.5 101.0 5.96 2.2 700 19.1 14.3 0.75 1.10 22.9 17.3 1.7 5.0 1.7 3.9 500 23.8 1.21 19.7 114.0 5.77 2.5 500 18.9 13.3 0.71 1.01 22.3 18.7 1.5 700 24.6 1.18 20.5 102.5 6.11 2.3 700 19.3 14.5 0.75 1.04 22.9 18.5 1.6 7.0 3.1 7.1 500 24.2 1.22 20.0 114.8 5.80 2.6 500 19.1 13.3 0.70 0.98 22.4 19.5 1.4 700 25.0 1.19 20.9 103.0 6.15 2.4 700 19.5 14.5 0.75 1.01 22.9 19.2 1.6 90 3.0 0.7 1.5 500 24.7 1.21 20.6 115.7 5.99 2.7 500 17.1 12.5 0.73 1.22 21.3 14.0 2.2 700 25.5 1.17 21.5 103.8 6.38 2.5 700 17.5 13.5 0.77 1.26 21.8 13.9 2.3 5.0 1.6 3.7 500 25.8 1.24 21.5 117.7 6.10 2.8 500 17.3 12.6 0.73 1.16 21.2 14.9 2.0 700 26.7 1.19 22.6 105.3 6.54 2.6 700 17.6 13.7 0.78 1.19 21.7 14.9 2.2 7.0 3.0 6.9 500 26.2 1.25 21.9 118.5 6.12 2.9 500 17.5 12.6 0.72 1.12 21.3 15.7 1.9 700 27.2 1.21 23.0 105.9 6.59 2.7 700 17.8 13.7 0.77 1.16 21.7 15.4 2.1 100 3.0 0.6 1.5 Operation not recommended Operation not recommended 5.0 1.6 3.6 500 16.7 12.5 0.75 1.32 21.2 12.6 2.6 700 17.0 13.6 0.80 1.36 21.6 12.5 2.8 7.0 2.9 6.6 500 16.9 12.5 0.74 1.28 21.2 13.2 2.4 700 17.2 13.6 0.79 1.32 21.7 13.0 2.7 110 3.0 0.6 1.4 Operation not recommended 5.0 1.5 3.4 500 14.6 11.5 0.79 1.50 19.7 9.7 3.3 700 14.9 12.5 0.84 1.54 20.2 9.7 3.6 7.0 2.8 6.4 500 14.8 11.5 0.78 1.46 19.7 10.1 3.1 700 15.1 12.5 0.83 1.50 20.2 10.0 3.4 120 3.0 0.6 1.3 Operation not recommended 5.0 1.4 3.3 500 14.0 11.4 0.82 1.71 19.8 8.2 4.1 700 14.2 12.4 0.87 1.75 20.2 8.1 4.4 7.0 2.7 6.1 500 14.1 11.4 0.81 1.65 19.7 8.5 3.8 700 14.4 12.4 0.86 1.70 20.2 8.5 4.2 Multiple Flow Rates (for EWT) are shown in the table above. The lowest flow rate shown is used for geothermal open loop/well water systems with a minimum 50° F. The second flow rate shown is the minimum geothermal closed loop flow rate. The third flow rate shown is optimum for geothermal closed loop and the suggested flow rate for boiler tower applications. 33 5 SERIES 500R11 SPECIFICATION CATALOG NDZ026 - Performance Data NDZ026 - Dual Capacity High Speed (900 cfm) EWT °F Flow GPM WPD HEATING - EAT 70°F COOLING - EAT 80/67 °F PSI FT Airflow CFM HC kBtuh Power kW HE kBtuh LAT °F COP HWC kBtuh Airflow CFM TC kBtuh SC kBtuh S/T Ratio Power kW HR kBtuh EER HWC kBtuh 20 4.0 1.4 3.2 Operation not recommended Operation not recommended6.0 2.9 6.6 8.0 4.8 11.1 700 15.7 1.42 10.9 90.8 3.25 2.0 900 16.0 1.43 11.1 86.4 3.27 1.8 30 4.0 1.4 3.2 Operation not recommended Operation not recommended 6.0 2.8 6.4 700 18.1 1.46 13.1 93.9 3.63 2.2 700 26.1 17.2 0.66 0.94 29.3 27.9 - 900 18.4 1.47 13.4 89.0 3.68 2.0 900 26.5 18.8 0.71 0.99 29.9 26.9 - 8.0 4.7 10.8 700 18.4 1.47 13.4 94.4 3.68 2.2 700 26.2 17.2 0.66 0.91 29.3 28.9 - 900 18.7 1.48 13.6 89.2 3.69 2.0 900 26.8 18.8 0.70 0.95 30.1 28.2 - 40 4.0 1.3 3.1 Operation not recommended Operation not recommended 6.0 2.7 6.2 700 21.0 1.52 15.8 97.8 4.06 2.4 700 26.4 17.7 0.67 1.02 29.9 26.0 - 900 21.4 1.52 16.2 92.0 4.13 2.2 900 26.9 19.3 0.72 1.07 30.6 25.2 - 8.0 4.5 10.4 700 21.4 1.53 16.1 98.3 4.08 2.5 700 26.7 17.7 0.66 0.99 30.0 27.0 - 900 21.8 1.53 16.5 92.4 4.16 2.3 900 27.2 19.3 0.71 1.03 30.8 26.4 - 50 4.0 1.3 3.0 700 22.7 1.55 17.4 100.0 4.28 2.6 700 26.3 17.9 0.68 1.19 30.3 22.2 1.2 900 23.1 1.55 17.8 93.8 4.36 2.4 900 26.8 19.5 0.73 1.23 31.0 21.7 1.3 6.0 2.6 6.0 700 23.8 1.59 18.4 101.5 4.40 2.7 700 26.5 18.1 0.68 1.13 30.4 23.6 1.1 900 24.3 1.59 18.8 95.0 4.48 2.5 900 27.1 19.7 0.73 1.17 31.1 23.1 1.2 8.0 4.4 10.1 700 24.2 1.61 18.7 101.9 4.40 2.8 700 26.8 18.1 0.67 1.09 30.5 24.6 1.0 900 24.7 1.60 19.3 95.4 4.53 2.6 900 27.4 19.7 0.72 1.14 31.2 24.0 1.2 60 4.0 1.2 2.9 700 25.5 1.64 19.9 103.7 4.57 3.0 700 26.0 17.8 0.68 1.29 30.4 20.2 1.4 900 26.1 1.62 20.6 96.8 4.72 2.7 900 26.5 19.3 0.73 1.34 31.0 19.8 1.5 6.0 2.5 5.8 700 26.7 1.67 21.0 105.3 4.69 3.1 700 26.2 17.9 0.68 1.22 30.4 21.5 1.3 900 27.4 1.66 21.7 98.2 4.84 2.8 900 26.8 19.5 0.73 1.27 31.1 21.1 1.5 8.0 4.2 9.8 700 27.2 1.69 21.4 105.9 4.71 3.1 700 26.5 17.9 0.68 1.19 30.5 22.3 1.3 900 27.8 1.67 22.1 98.6 4.89 2.9 900 27.0 19.5 0.72 1.23 31.2 21.9 1.4 70 4.0 1.2 2.8 700 28.5 1.72 22.6 107.6 4.84 3.3 700 25.6 17.7 0.69 1.43 30.5 17.9 1.8 900 29.1 1.69 23.4 100.0 5.06 3.1 900 26.1 19.2 0.74 1.49 31.2 17.6 1.9 6.0 2.4 5.6 700 29.7 1.76 23.7 109.3 4.96 3.4 700 25.8 17.8 0.69 1.35 30.5 19.1 1.7 900 30.6 1.73 24.7 101.5 5.17 3.2 900 26.4 19.5 0.74 1.41 31.3 18.8 1.8 8.0 4.1 9.5 700 30.3 1.78 24.2 110.0 4.99 3.5 700 26.1 17.8 0.68 1.32 30.6 19.8 1.5 900 31.1 1.75 25.1 102.0 5.22 3.3 900 26.6 19.5 0.73 1.36 31.3 19.5 1.7 80 4.0 1.2 2.7 700 31.0 1.83 24.8 111.1 4.98 3.7 700 24.6 17.4 0.71 1.59 30.0 15.5 2.2 900 31.9 1.78 25.9 102.9 5.26 3.5 900 25.1 18.9 0.75 1.64 30.7 15.3 2.4 6.0 2.4 5.4 700 32.4 1.87 26.0 112.9 5.09 3.8 700 24.8 17.5 0.71 1.50 30.0 16.5 2.1 900 33.5 1.82 27.3 104.4 5.39 3.6 900 25.4 19.1 0.75 1.55 30.7 16.4 2.3 8.0 4.0 9.2 700 33.0 1.89 26.5 113.6 5.11 4.0 700 25.1 17.5 0.70 1.46 30.1 17.3 1.9 900 34.0 1.84 27.8 105.0 5.43 3.7 900 25.6 19.1 0.75 1.51 30.7 17.0 2.1 90 4.0 1.1 2.6 700 33.7 1.94 27.1 114.6 5.10 4.2 700 23.3 16.8 0.72 1.75 29.3 13.3 2.8 900 34.9 1.88 28.5 105.9 5.44 3.9 900 23.9 18.2 0.76 1.81 30.0 13.2 3.0 6.0 2.3 5.2 700 35.2 1.98 28.4 116.6 5.20 4.3 700 23.5 17.0 0.72 1.66 29.2 14.2 2.6 900 36.4 1.91 29.9 107.5 5.58 4.0 900 24.1 18.5 0.77 1.71 29.9 14.1 2.8 8.0 3.8 8.8 700 35.8 2.01 28.9 117.3 5.22 4.4 700 23.9 17.0 0.71 1.60 29.3 14.9 2.4 900 37.1 1.94 30.5 108.2 5.61 4.1 900 24.3 18.5 0.76 1.66 29.9 14.6 2.7 100 4.0 1.1 2.5 Operation not recommended Operation not recommended 6.0 2.2 5.1 700 22.4 16.5 0.74 1.86 28.7 12.0 3.2 900 22.8 17.9 0.78 1.91 29.4 11.9 3.5 8.0 3.7 8.5 700 22.6 16.5 0.73 1.80 28.8 12.6 3.0 900 23.0 17.9 0.78 1.86 29.4 12.4 3.3 110 4.0 1.0 2.4 Operation not recommended 6.0 2.1 4.9 700 20.5 15.5 0.76 2.06 27.5 10.0 3.9 900 20.9 16.9 0.81 2.12 28.1 9.9 4.2 8.0 3.5 8.2 700 20.7 15.5 0.75 2.00 27.5 10.4 3.6 900 21.1 16.9 0.80 2.06 28.1 10.3 4.0 120 4.0 1.0 2.3 Operation not recommended 6.0 2.0 4.7 700 19.0 14.9 0.79 2.31 26.8 8.2 4.7 900 19.3 16.2 0.84 2.37 27.4 8.2 5.1 8.0 3.4 7.9 700 19.1 14.9 0.78 2.23 26.7 8.6 4.4 900 19.5 16.2 0.83 2.30 27.4 8.5 4.8 Multiple Flow Rates (for EWT) are shown in the table above. The lowest flow rate shown is used for geothermal open loop/well water systems with a minimum 50° F. The second flow rate shown is the minimum geothermal closed loop flow rate. The third flow rate shown is optimum for geothermal closed loop and the suggested flow rate for boiler tower applications. 34 5 SERIES 500R11 SPECIFICATION CATALOG NDZ038 - Performance Data NDZ038 - Dual Capacity Low Speed (1050 cfm) EWT °F Flow GPM WPD HEATING - EAT 70°F COOLING - EAT 80/67 °F PSI FT Airflow CFM HC kBtuh Power kW HE kBtuh LAT °F COP HWC kBtuh Airflow CFM TC kBtuh SC kBtuh S/T Ratio Power kW HR kBtuh EER HWC kBtuh 20 4.0 0.9 2.1 Operation not recommended Operation not recommended6.0 1.7 4.0 8.0 2.9 6.7 900 15.5 1.47 10.5 85.9 3.10 2.5 1050 16.1 1.50 11.0 84.2 3.15 2.2 30 4.0 0.9 2.0 Operation not recommended Operation not recommended 6.0 1.7 3.9 900 17.2 1.45 12.3 87.7 3.48 2.4 900 26.6 16.8 0.63 0.73 29.1 36.5 - 1050 17.9 1.49 12.8 85.8 3.53 2.2 1050 27.3 18.6 0.68 0.74 29.8 36.8 - 8.0 2.8 6.5 900 18.3 1.49 13.2 88.8 3.61 2.5 900 27.0 17.3 0.64 0.72 29.5 37.4 - 1050 19.1 1.53 13.9 86.8 3.66 2.2 1050 27.8 19.1 0.69 0.74 30.3 37.7 - 40 4.0 0.8 1.9 Operation not recommended Operation not recommended 6.0 1.6 3.8 900 20.3 1.48 15.3 90.9 4.03 2.5 900 27.7 18.0 0.65 0.79 30.4 35.1 - 1050 21.0 1.51 15.9 88.6 4.09 2.3 1050 28.4 19.9 0.70 0.80 31.2 35.3 - 8.0 2.7 6.3 900 21.4 1.51 16.3 92.0 4.15 2.6 900 28.1 18.5 0.66 0.78 30.8 35.9 - 1050 22.2 1.54 16.9 89.5 4.21 2.3 1050 28.9 20.4 0.71 0.80 31.6 36.2 - 50 4.0 0.8 1.9 900 22.4 1.50 17.3 93.0 4.36 2.6 900 28.6 19.3 0.67 0.90 31.6 31.8 0.9 1050 23.1 1.53 17.9 90.4 4.44 2.4 1050 29.4 21.3 0.73 0.92 32.5 32.1 1.0 6.0 1.6 3.7 900 23.2 1.51 18.0 93.9 4.51 2.7 900 28.8 19.4 0.67 0.88 31.8 33.0 0.8 1050 23.9 1.52 18.7 91.1 4.59 2.4 1050 29.6 21.5 0.72 0.89 32.7 33.2 0.9 8.0 2.6 6.1 900 24.3 1.54 19.0 95.0 4.62 2.7 900 29.3 19.9 0.68 0.87 32.3 33.8 0.8 1050 25.0 1.56 19.7 92.0 4.70 2.5 1050 30.1 22.0 0.73 0.88 33.1 34.1 0.9 60 4.0 0.8 1.8 900 25.3 1.53 20.0 96.0 4.83 2.8 900 27.4 18.6 0.68 1.00 30.9 27.3 1.2 1050 25.9 1.54 20.6 92.8 4.91 2.6 1050 28.2 20.6 0.73 1.02 31.7 27.6 1.3 6.0 1.5 3.6 900 26.3 1.53 21.1 97.0 5.03 2.9 900 27.7 18.7 0.67 0.98 31.0 28.3 1.1 1050 26.9 1.54 21.6 93.7 5.12 2.7 1050 28.5 20.7 0.73 1.00 31.9 28.5 1.2 8.0 2.5 5.9 900 27.2 1.57 21.8 98.0 5.09 3.0 900 28.1 19.2 0.68 0.97 31.5 29.0 1.1 1050 27.8 1.57 22.4 94.5 5.18 2.7 1050 28.9 21.2 0.73 0.99 32.3 29.3 1.2 70 4.0 0.8 1.8 900 28.0 1.56 22.7 98.9 5.27 3.1 900 27.1 18.8 0.69 1.14 31.0 23.8 1.7 1050 28.6 1.56 23.3 95.2 5.37 2.9 1050 27.8 20.8 0.75 1.16 31.8 24.0 1.8 6.0 1.5 3.5 900 29.3 1.55 24.0 100.1 5.52 3.2 900 27.3 18.9 0.69 1.11 31.1 24.7 1.6 1050 29.8 1.55 24.5 96.3 5.63 3.0 1050 28.1 21.0 0.75 1.13 32.0 24.9 1.7 8.0 2.5 5.7 900 30.0 1.59 24.6 100.9 5.55 3.3 900 27.8 19.4 0.70 1.10 31.5 25.3 1.5 1050 30.6 1.58 25.2 96.9 5.65 3.1 1050 28.6 21.5 0.75 1.12 32.4 25.5 1.6 80 4.0 0.7 1.7 900 30.7 1.59 25.3 101.6 5.66 3.5 900 26.1 18.4 0.71 1.30 30.5 20.1 2.3 1050 31.1 1.58 25.7 97.4 5.77 3.3 1050 26.8 20.4 0.76 1.32 31.3 20.3 2.5 6.0 1.4 3.3 900 32.2 1.58 26.8 103.1 5.97 3.6 900 26.3 18.6 0.71 1.26 30.6 20.8 2.2 1050 32.6 1.57 27.2 98.7 6.09 3.3 1050 27.0 20.5 0.76 1.29 31.4 21.0 2.4 8.0 2.4 5.5 900 32.6 1.61 27.1 103.6 5.93 3.7 900 26.7 19.0 0.71 1.25 31.0 21.4 2.0 1050 33.0 1.60 27.5 99.1 6.05 3.4 1050 27.5 21.1 0.77 1.28 31.8 21.5 2.2 90 4.0 0.7 1.6 900 33.3 1.62 27.8 104.3 6.04 4.0 900 24.2 17.2 0.71 1.48 29.2 16.4 3.1 1050 33.6 1.60 28.1 99.6 6.16 3.7 1050 24.8 19.1 0.77 1.50 30.0 16.5 3.3 6.0 1.4 3.2 900 35.0 1.60 29.5 106.0 6.41 4.1 900 24.4 17.3 0.71 1.44 29.3 17.0 2.9 1050 35.2 1.58 29.8 101.1 6.54 3.8 1050 25.1 19.2 0.77 1.47 30.1 17.1 3.1 8.0 2.3 5.3 900 35.2 1.63 29.6 106.2 6.31 4.2 900 24.8 17.8 0.72 1.43 29.6 17.4 2.7 1050 35.3 1.61 29.8 101.2 6.44 3.9 1050 25.5 19.7 0.77 1.45 30.4 17.5 3.0 100 4.0 0.7 1.6 Operation not recommended Operation not recommended 6.0 1.3 3.1 900 23.5 17.6 0.75 1.64 29.1 14.3 3.8 1050 24.2 19.5 0.81 1.67 29.9 14.4 4.1 8.0 2.2 5.1 900 23.9 18.1 0.76 1.63 29.5 14.7 3.5 1050 24.6 20.0 0.81 1.66 30.2 14.8 3.9 110 4.0 0.7 1.5 Operation not recommended 6.0 1.3 3.0 900 21.1 16.6 0.79 1.87 27.5 11.3 4.8 1050 21.7 18.3 0.85 1.90 28.2 11.4 5.2 8.0 2.1 4.9 900 21.4 17.0 0.79 1.85 27.8 11.6 4.4 1050 22.0 18.8 0.85 1.89 28.5 11.7 4.9 120 4.0 0.6 1.5 Operation not recommended 6.0 1.2 2.9 900 20.0 16.4 0.82 2.12 27.2 9.4 5.9 1050 20.5 18.2 0.88 2.16 27.9 9.5 6.4 8.0 2.0 4.7 900 20.3 16.8 0.83 2.10 27.5 9.7 5.5 1050 20.9 18.6 0.89 2.14 28.2 9.7 6.1 Multiple Flow Rates (for EWT) are shown in the table above. The lowest flow rate shown is used for geothermal open loop/well water systems with a minimum 50° F. The second flow rate shown is the minimum geothermal closed loop flow rate. The third flow rate shown is optimum for geothermal closed loop and the suggested flow rate for boiler tower applications. 35 5 SERIES 500R11 SPECIFICATION CATALOG NDZ038 - Performance Data NDZ038 - Dual Capacity High Speed (1250 cfm) EWT °F Flow GPM WPD HEATING - EAT 70°F COOLING - EAT 80/67 °F PSI FT Airflow CFM HC kBtuh Power kW HE kBtuh LAT °F COP HWC kBtuh Airflow CFM TC kBtuh SC kBtuh S/T Ratio Power kW HR kBtuh EER HWC kBtuh 20 5.0 1.3 3.0 Operation not recommended Operation not recommended7.0 2.3 5.2 9.0 3.5 8.1 1050 22.1 2.12 14.9 89.5 3.06 2.8 1250 22.9 2.18 15.4 86.9 3.07 2.5 30 5.0 1.2 2.9 Operation not recommended Operation not recommended 7.0 2.2 5.1 1050 25.5 2.16 18.1 92.5 3.46 3.0 1050 34.5 20.5 0.59 1.47 39.5 23.5 - 1250 26.2 2.23 18.7 89.4 3.46 2.8 1250 36.5 22.8 0.63 1.55 41.8 23.5 - 9.0 3.4 7.9 1050 25.9 2.18 18.5 92.9 3.48 3.1 1050 34.7 22.5 0.65 1.42 39.6 24.4 - 1250 26.8 2.25 19.1 89.8 3.49 2.8 1250 36.8 25.0 0.68 1.51 42.0 24.3 - 40 5.0 1.2 2.8 Operation not recommended Operation not recommended 7.0 2.1 4.9 1050 29.8 2.29 22.0 96.3 3.81 3.4 1050 35.8 21.9 0.61 1.62 41.4 22.1 - 1250 30.7 2.34 22.7 92.7 3.85 3.1 1250 37.8 24.4 0.65 1.70 43.6 22.2 - 9.0 3.3 7.6 1050 30.4 2.31 22.5 96.8 3.85 3.5 1050 36.1 23.8 0.66 1.57 41.5 23.0 - 1250 31.3 2.36 23.3 93.2 3.89 3.2 1250 38.2 26.4 0.69 1.67 43.8 22.9 - 50 5.0 1.2 2.7 1050 32.3 2.35 24.3 98.5 4.03 3.6 1050 36.0 22.8 0.63 1.92 42.6 18.8 1.7 1250 33.2 2.38 25.1 94.6 4.10 3.4 1250 37.9 25.4 0.67 2.02 44.8 18.8 1.9 7.0 2.1 4.8 1050 33.4 2.40 25.3 99.5 4.09 3.8 1050 36.8 23.1 0.63 1.81 43.0 20.4 1.6 1250 34.5 2.43 26.2 95.6 4.16 3.5 1250 38.7 25.7 0.66 1.90 45.2 20.4 1.8 9.0 3.2 7.4 1050 34.2 2.42 25.9 100.2 4.14 3.9 1050 37.2 24.7 0.66 1.76 43.2 21.1 1.5 1250 35.3 2.45 26.9 96.1 4.21 3.5 1250 39.1 27.4 0.70 1.85 45.5 21.1 1.7 60 5.0 1.1 2.6 1050 35.6 2.46 27.2 101.4 4.24 4.1 1050 35.7 23.4 0.66 2.04 42.6 17.4 2.1 1250 36.7 2.48 28.3 97.2 4.35 3.8 1250 37.4 26.0 0.70 2.14 44.7 17.5 2.2 7.0 2.0 4.6 1050 37.2 2.53 28.6 102.8 4.31 4.2 1050 36.5 23.6 0.65 1.94 43.1 18.8 2.0 1250 38.4 2.55 29.7 98.4 4.42 3.9 1250 38.2 26.2 0.69 2.02 45.1 18.9 2.1 9.0 3.1 7.2 1050 38.1 2.56 29.4 103.6 4.36 4.4 1050 36.9 24.9 0.68 1.89 43.3 19.5 1.8 1250 39.3 2.57 30.6 99.1 4.49 4.0 1250 38.7 27.6 0.71 1.98 45.4 19.5 2.0 70 5.0 1.1 2.5 1050 39.0 2.59 30.1 104.4 4.40 4.6 1050 35.6 24.2 0.68 2.24 43.3 15.9 2.6 1250 40.3 2.59 31.5 99.9 4.56 4.3 1250 37.2 26.9 0.72 2.33 45.1 16.0 2.8 7.0 1.9 4.5 1050 41.0 2.68 31.8 106.1 4.48 4.7 1050 36.5 24.5 0.67 2.15 43.9 17.0 2.4 1250 42.3 2.68 33.2 101.3 4.63 4.4 1250 38.1 27.1 0.71 2.22 45.7 17.2 2.6 9.0 3.0 6.9 1050 42.0 2.71 32.8 107.1 4.54 4.9 1050 36.9 25.4 0.69 2.09 44.1 17.6 2.3 1250 43.5 2.70 34.3 102.2 4.72 4.5 1250 38.6 28.2 0.73 2.18 46.0 17.7 2.5 80 5.0 1.1 2.5 1050 41.5 2.70 32.3 106.6 4.50 5.2 1050 34.4 23.8 0.69 2.44 42.7 14.1 3.2 1250 42.9 2.68 33.8 101.8 4.70 4.8 1250 35.7 26.5 0.74 2.51 44.3 14.2 3.4 7.0 1.9 4.3 1050 43.9 2.81 34.3 108.7 4.58 5.3 1050 35.3 24.1 0.68 2.35 43.3 15.0 3.0 1250 45.4 2.78 35.9 103.6 4.78 4.9 1250 36.7 26.8 0.73 2.42 45.0 15.2 3.3 9.0 2.9 6.7 1050 45.1 2.84 35.4 109.8 4.65 5.5 1050 35.7 24.7 0.69 2.31 43.6 15.5 2.8 1250 46.7 2.80 37.1 104.6 4.88 5.1 1250 37.2 27.4 0.74 2.37 45.3 15.6 3.1 90 5.0 1.0 2.4 1050 44.0 2.82 34.4 108.8 4.57 5.8 1050 32.5 23.2 0.71 2.63 41.4 12.3 4.0 1250 45.6 2.78 36.1 103.8 4.81 5.3 1250 33.6 25.8 0.77 2.70 42.8 12.5 4.3 7.0 1.8 4.2 1050 46.8 2.95 36.7 111.2 4.65 6.0 1050 33.4 23.5 0.70 2.56 42.1 13.1 3.8 1250 48.4 2.90 38.6 105.9 4.90 5.5 1250 34.7 26.1 0.75 2.62 43.6 13.2 4.1 9.0 2.8 6.5 1050 48.2 2.99 38.0 112.5 4.73 6.1 1050 33.8 23.7 0.70 2.51 42.4 13.4 3.5 1250 49.9 2.92 40.0 107.0 5.01 5.7 1250 35.0 26.3 0.75 2.57 43.8 13.6 3.9 100 5.0 1.0 2.3 Operation not recommended Operation not recommended 7.0 1.7 4.0 1050 32.2 23.3 0.72 2.85 41.9 11.3 4.7 1250 33.3 25.9 0.78 2.90 43.1 11.5 5.0 9.0 2.7 6.2 1050 32.6 23.2 0.71 2.80 42.1 11.6 4.3 1250 33.6 25.7 0.76 2.85 43.3 11.8 4.8 110 5.0 1.0 2.2 Operation not recommended 7.0 1.7 3.9 1050 29.5 21.9 0.74 3.12 40.1 9.5 5.7 1250 30.3 24.3 0.80 3.14 41.0 9.6 6.1 9.0 2.6 6.0 1050 29.8 21.6 0.73 3.06 40.2 9.7 5.3 1250 30.6 23.8 0.78 3.09 41.1 9.9 5.8 120 5.0 0.9 2.1 Operation not recommended 7.0 1.6 3.7 1050 27.7 21.4 0.77 3.48 39.6 8.0 6.8 1250 28.3 23.9 0.84 3.48 40.2 8.2 7.4 9.0 2.5 5.8 1050 28.0 20.9 0.75 3.42 39.6 8.2 6.3 1250 28.6 23.0 0.81 3.43 40.3 8.3 7.0 Multiple Flow Rates (for EWT) are shown in the table above. The lowest flow rate shown is used for geothermal open loop/well water systems with a minimum 50° F. The second flow rate shown is the minimum geothermal closed loop flow rate. The third flow rate shown is optimum for geothermal closed loop and the suggested flow rate for boiler tower applications. 36 5 SERIES 500R11 SPECIFICATION CATALOG NDZ049 - Performance Data NDZ049 - Dual Capacity Low Speed (1350 cfm) EWT °F Flow GPM WPD HEATING - EAT 70°F COOLING - EAT 80/67 °F PSI FT Airflow CFM HC kBtuh Power kW HE kBtuh LAT °F COP HWC kBtuh Airflow CFM TC kBtuh SC kBtuh S/T Ratio Power kW HR kBtuh EER HWC kBtuh 20 5.0 0.9 2.2 Operation not recommended Operation not recommended8.0 2.0 4.6 11.0 3.4 7.8 1150 22.2 2.05 15.2 87.9 3.17 4.1 1350 23.0 2.08 15.9 85.8 3.24 3.7 30 5.0 0.9 2.1 Operation not recommended Operation not recommended 8.0 1.9 4.4 1150 25.6 2.09 18.4 90.6 3.58 4.2 1150 35.0 20.6 0.59 1.18 39.1 29.7 - 1350 26.3 2.10 19.2 88.1 3.67 3.8 1350 36.3 24.2 0.67 1.25 40.6 28.9 - 11.0 3.3 7.6 1150 26.2 2.10 19.0 91.1 3.65 4.3 1150 35.1 20.5 0.58 1.10 38.9 31.9 - 1350 27.1 2.13 19.8 88.6 3.73 3.9 1350 36.1 24.2 0.67 1.17 40.0 30.8 - 40 5.0 0.9 2.0 Operation not recommended Operation not recommended 8.0 1.9 4.3 1150 29.3 2.16 21.9 93.6 3.97 4.5 1150 37.0 22.5 0.61 1.30 41.5 28.5 - 1350 30.4 2.16 23.0 90.8 4.11 4.1 1350 38.3 26.5 0.69 1.37 42.9 27.9 - 11.0 3.2 7.4 1150 30.3 2.18 22.9 94.4 4.07 4.6 1150 37.2 22.4 0.60 1.22 41.3 30.5 - 1350 31.3 2.19 23.8 91.5 4.18 4.2 1350 38.2 26.4 0.69 1.29 42.6 29.7 - 50 5.0 0.9 2.0 1150 30.4 2.16 23.0 94.5 4.13 4.7 1150 37.8 24.0 0.64 1.68 43.5 22.5 1.6 1350 31.4 2.16 24.0 91.5 4.26 4.3 1350 38.9 28.3 0.73 1.75 44.9 22.2 1.6 8.0 1.8 4.2 1150 32.8 2.23 25.1 96.4 4.31 4.8 1150 38.6 24.1 0.62 1.45 43.5 26.5 1.4 1350 34.0 2.21 26.4 93.3 4.50 4.4 1350 39.8 28.4 0.71 1.52 45.0 26.1 1.6 11.0 3.1 7.2 1150 34.0 2.24 26.4 97.4 4.44 5.0 1150 38.8 24.1 0.62 1.37 43.5 28.4 1.3 1350 35.1 2.24 27.5 94.1 4.59 4.5 1350 40.0 28.4 0.71 1.44 44.9 27.8 1.5 60 5.0 0.8 1.9 1150 33.2 2.24 25.6 96.7 4.34 5.1 1150 37.6 24.0 0.64 1.81 43.7 20.8 2.2 1350 34.4 2.23 26.8 93.6 4.53 4.8 1350 38.8 28.2 0.73 1.89 45.2 20.5 2.3 8.0 1.8 4.0 1150 35.9 2.30 28.1 98.9 4.58 5.3 1150 38.2 24.1 0.63 1.61 43.7 23.8 2.0 1350 37.3 2.27 29.6 95.6 4.82 4.9 1350 39.4 28.4 0.72 1.68 45.1 23.4 2.2 11.0 3.0 6.9 1150 37.5 2.32 29.5 100.2 4.74 5.5 1150 38.6 24.2 0.63 1.52 43.8 25.3 1.9 1350 38.8 2.29 31.0 96.6 4.96 5.0 1350 39.8 28.5 0.72 1.59 45.2 25.0 2.1 70 5.0 0.8 1.8 1150 35.9 2.32 28.0 98.9 4.54 5.7 1150 37.8 25.2 0.67 1.99 44.6 19.0 3.1 1350 37.3 2.29 29.5 95.6 4.77 5.3 1350 39.0 29.6 0.76 2.09 46.1 18.7 3.3 8.0 1.7 3.9 1150 39.0 2.36 30.9 101.4 4.84 5.9 1150 38.2 25.4 0.67 1.81 44.3 21.1 2.9 1350 40.5 2.32 32.6 97.8 5.12 5.4 1350 39.4 29.9 0.76 1.89 45.8 20.9 3.1 11.0 2.9 6.7 1150 40.7 2.39 32.6 102.8 5.00 6.1 1150 38.8 25.6 0.66 1.73 44.7 22.5 2.7 1350 42.3 2.33 34.3 99.0 5.31 5.6 1350 40.0 30.0 0.75 1.79 46.1 22.3 3.0 80 5.0 0.8 1.8 1150 38.1 2.38 30.0 100.7 4.70 6.4 1150 36.6 24.1 0.66 2.17 44.0 16.8 4.3 1350 39.6 2.34 31.6 97.2 4.97 5.9 1350 37.7 28.3 0.75 2.27 45.5 16.6 4.5 8.0 1.6 3.8 1150 41.4 2.40 33.2 103.3 5.05 6.6 1150 36.8 24.4 0.66 2.02 43.7 18.2 4.0 1350 43.1 2.34 35.1 99.5 5.39 6.1 1350 37.9 28.7 0.76 2.10 45.0 18.0 4.3 11.0 2.8 6.5 1150 43.5 2.43 35.2 105.0 5.25 6.8 1150 37.6 24.6 0.65 1.93 44.2 19.5 3.7 1350 45.3 2.36 37.2 101.0 5.61 6.2 1350 38.8 28.9 0.74 2.01 45.6 19.3 4.1 90 5.0 0.7 1.7 1150 40.2 2.43 31.9 102.4 4.85 7.1 1150 34.5 22.2 0.64 2.38 42.6 14.5 5.7 1350 41.8 2.38 33.7 98.7 5.16 6.6 1350 35.6 26.1 0.73 2.47 44.0 14.4 6.0 8.0 1.6 3.6 1150 43.7 2.44 35.4 105.2 5.25 7.3 1150 34.5 22.5 0.65 2.25 42.2 15.3 5.3 1350 45.5 2.36 37.5 101.2 5.65 6.8 1350 35.5 26.4 0.75 2.34 43.4 15.2 5.8 11.0 2.7 6.2 1150 46.1 2.47 37.7 107.1 5.48 7.5 1150 35.5 22.7 0.64 2.16 42.8 16.4 4.9 1350 48.1 2.39 39.9 103.0 5.90 7.0 1350 36.6 26.7 0.73 2.25 44.3 16.2 5.5 100 5.0 0.7 1.7 Operation not recommended Operation not recommended 8.0 1.5 3.5 1150 32.9 23.1 0.70 2.53 41.5 13.0 6.9 1350 33.9 27.2 0.80 2.63 42.9 12.9 7.5 11.0 2.6 6.0 1150 34.1 23.5 0.69 2.44 42.4 14.0 6.4 1350 35.1 27.6 0.79 2.55 43.8 13.8 7.1 110 5.0 0.7 1.6 Operation not recommended 8.0 1.5 3.4 1150 29.5 21.8 0.74 2.82 39.1 10.5 8.7 1350 30.5 25.6 0.84 2.94 40.5 10.4 9.5 11.0 2.5 5.8 1150 30.9 22.2 0.72 2.73 40.2 11.3 8.1 1350 31.8 26.0 0.82 2.85 41.5 11.1 9.0 120 5.0 0.7 1.5 Operation not recommended 8.0 1.4 3.3 1150 27.2 21.2 0.78 3.15 38.0 8.6 10.8 1350 28.2 24.9 0.89 3.29 39.4 8.6 11.7 11.0 2.4 5.6 1150 28.8 21.6 0.75 3.06 39.2 9.4 10.1 1350 29.5 25.4 0.86 3.21 40.5 9.2 11.2 Multiple Flow Rates (for EWT) are shown in the table above. The lowest flow rate shown is used for geothermal open loop/well water systems with a minimum 50° F. The second flow rate shown is the minimum geothermal closed loop flow rate. The third flow rate shown is optimum for geothermal closed loop and the suggested flow rate for boiler tower applications. 37 5 SERIES 500R11 SPECIFICATION CATALOG NDZ049 - Performance Data NDZ049 - Dual Capacity High Speed (1550 cfm) EWT °F Flow GPM WPD HEATING - EAT 70°F COOLING - EAT 80/67 °F PSI FT Airflow CFM HC kBtuh Power kW HE kBtuh LAT °F COP HWC kBtuh Airflow CFM TC kBtuh SC kBtuh S/T Ratio Power kW HR kBtuh EER HWC kBtuh 20 6.0 1.3 3.0 Operation not recommended Operation not recommended9.0 2.5 5.7 12.0 4.0 9.2 1350 30.7 2.74 21.3 91.0 3.28 5.2 1550 31.7 2.82 22.1 88.9 3.29 4.7 30 6.0 1.2 2.9 Operation not recommended Operation not recommended 9.0 2.4 5.5 1350 35.0 2.87 25.2 94.0 3.58 5.5 1350 46.3 28.5 0.62 1.90 52.8 24.4 - 1550 36.1 2.96 26.0 91.5 3.57 5.1 1550 49.1 31.8 0.65 2.02 56.0 24.3 - 12.0 3.9 8.9 1350 35.5 2.90 25.6 94.4 3.60 5.7 1350 46.8 28.5 0.61 1.81 53.0 25.9 - 1550 36.7 2.99 26.5 91.9 3.60 5.2 1550 49.5 31.7 0.64 1.93 56.1 25.7 - 40 6.0 1.2 2.8 Operation not recommended Operation not recommended 9.0 2.3 5.3 1350 39.9 3.00 29.7 97.4 3.90 6.1 1350 48.0 30.2 0.63 2.10 55.2 22.9 - 1550 41.1 3.06 30.6 94.5 3.93 5.6 1550 50.8 33.6 0.66 2.22 58.4 22.9 - 12.0 3.7 8.7 1350 40.6 3.03 30.3 97.9 3.93 6.3 1350 48.6 30.2 0.62 2.01 55.4 24.2 - 1550 42.0 3.09 31.4 95.1 3.97 5.7 1550 51.2 33.6 0.66 2.13 58.5 24.1 - 50 6.0 1.2 2.7 1350 42.7 3.10 32.1 99.3 4.03 6.6 1350 48.6 31.0 0.64 2.50 57.2 19.4 2.9 1550 44.1 3.14 33.3 96.3 4.11 6.1 1550 51.2 34.4 0.67 2.64 60.2 19.4 3.1 9.0 2.2 5.2 1350 44.4 3.16 33.6 100.4 4.11 6.8 1350 49.2 31.4 0.64 2.35 57.2 21.0 2.7 1550 45.6 3.21 34.7 97.3 4.17 6.2 1550 51.8 34.9 0.67 2.46 60.2 21.0 2.9 12.0 3.6 8.4 1350 45.2 3.20 34.3 101.0 4.15 7.0 1350 49.7 31.5 0.63 2.26 57.4 22.0 2.5 1550 46.7 3.24 35.7 97.9 4.23 6.4 1550 52.3 35.0 0.67 2.37 60.4 22.0 2.8 60 6.0 1.1 2.6 1350 46.6 3.23 35.6 102.0 4.23 7.4 1350 48.1 31.3 0.65 2.66 57.1 18.1 3.6 1550 48.1 3.24 37.0 98.7 4.34 6.8 1550 50.4 34.7 0.69 2.78 59.9 18.2 3.8 9.0 2.2 5.0 1350 48.7 3.31 37.4 103.4 4.31 7.6 1350 48.9 31.7 0.65 2.51 57.4 19.5 3.3 1550 50.2 3.33 38.8 100.0 4.42 7.0 1550 51.2 35.2 0.69 2.62 60.2 19.6 3.6 12.0 3.5 8.1 1350 49.8 3.35 38.4 104.2 4.36 7.8 1350 49.4 31.8 0.65 2.43 57.7 20.3 3.1 1550 51.4 3.36 40.0 100.7 4.49 7.2 1550 51.8 35.4 0.68 2.54 60.4 20.4 3.4 70 6.0 1.1 2.5 1350 50.4 3.34 39.0 104.6 4.42 8.3 1350 47.8 31.9 0.67 2.91 57.7 16.4 4.5 1550 52.0 3.33 40.6 101.1 4.57 7.7 1550 49.9 35.4 0.71 3.01 60.2 16.6 4.7 9.0 2.1 4.9 1350 52.9 3.44 41.2 106.3 4.50 8.6 1350 48.8 32.3 0.66 2.77 58.3 17.7 4.2 1550 54.6 3.43 42.8 102.6 4.66 7.9 1550 51.0 35.8 0.70 2.87 60.8 17.8 4.5 12.0 3.4 7.9 1350 54.3 3.49 42.4 107.2 4.56 8.8 1350 49.3 32.5 0.66 2.69 58.5 18.3 3.9 1550 56.0 3.47 44.2 103.5 4.73 8.1 1550 51.6 36.1 0.70 2.79 61.1 18.5 4.3 80 6.0 1.1 2.5 1350 53.5 3.52 41.5 106.7 4.45 9.3 1350 45.8 31.2 0.68 3.15 56.5 14.5 5.6 1550 55.2 3.48 43.4 103.0 4.65 8.6 1550 47.7 34.6 0.73 3.24 58.7 14.7 6.0 9.0 2.0 4.7 1350 56.5 3.65 44.0 108.7 4.54 9.6 1350 47.0 31.5 0.67 3.03 57.3 15.5 5.3 1550 58.3 3.60 46.0 104.8 4.74 8.9 1550 48.9 34.9 0.71 3.11 59.5 15.7 5.7 12.0 3.3 7.6 1350 58.1 3.69 45.5 109.8 4.62 9.9 1350 47.5 31.8 0.67 2.96 57.6 16.0 4.9 1550 60.0 3.64 47.6 105.8 4.83 9.2 1550 49.4 35.3 0.71 3.04 59.8 16.2 5.4 90 6.0 1.0 2.4 1350 56.5 3.68 43.9 108.7 4.49 10.5 1350 43.0 29.9 0.70 3.38 54.6 12.7 7.1 1550 58.4 3.61 46.1 104.9 4.74 9.7 1550 44.6 33.2 0.74 3.46 56.4 12.9 7.5 9.0 2.0 4.5 1350 59.9 3.84 46.8 111.1 4.58 10.8 1350 44.3 30.2 0.68 3.29 55.5 13.5 6.6 1550 61.9 3.76 49.1 107.0 4.83 10.0 1550 46.0 33.5 0.73 3.35 57.4 13.7 7.2 12.0 3.2 7.3 1350 61.8 3.87 48.6 112.4 4.67 11.2 1350 44.8 30.5 0.68 3.22 55.8 13.9 6.1 1550 63.9 3.80 50.9 108.2 4.92 10.3 1550 46.4 33.9 0.73 3.29 57.6 14.1 6.8 100 6.0 1.0 2.3 Operation not recommended Operation not recommended 9.0 1.9 4.4 1350 42.3 29.6 0.70 3.65 54.8 11.6 8.2 1550 43.7 32.7 0.75 3.70 56.3 11.8 8.9 12.0 3.1 7.1 1350 42.8 29.9 0.70 3.59 55.0 11.9 7.6 1550 44.1 33.2 0.75 3.64 56.5 12.1 8.5 110 6.0 1.0 2.2 Operation not recommended 9.0 1.8 4.2 1350 38.2 27.6 0.72 3.97 51.8 9.6 10.0 1550 39.3 30.5 0.78 4.00 52.9 9.8 10.9 12.0 2.9 6.8 1350 38.6 28.0 0.72 3.92 52.0 9.9 9.3 1550 39.7 31.0 0.78 3.95 53.2 10.0 10.4 120 6.0 0.9 2.1 Operation not recommended 9.0 1.7 4.0 1350 35.5 26.4 0.74 4.42 50.6 8.0 12.1 1550 36.3 29.2 0.80 4.42 51.4 8.2 13.2 12.0 2.8 6.5 1350 35.8 26.9 0.75 4.37 50.8 8.2 11.3 1550 36.6 29.7 0.81 4.37 51.6 8.4 12.5 Multiple Flow Rates (for EWT) are shown in the table above. The lowest flow rate shown is used for geothermal open loop/well water systems with a minimum 50° F. The second flow rate shown is the minimum geothermal closed loop flow rate. The third flow rate shown is optimum for geothermal closed loop and the suggested flow rate for boiler tower applications. 38 5 SERIES 500R11 SPECIFICATION CATALOG NDZ064 - Performance Data NDZ064 - Dual Capacity Low Speed (1500 cfm) EWT °F Flow GPM WPD HEATING - EAT 70°F COOLING - EAT 80/67 °F PSI FT Airflow CFM HC kBtuh Power kW HE kBtuh LAT °F COP HWC kBtuh Airflow CFM TC kBtuh SC kBtuh S/T Ratio Power kW HR kBtuh EER HWC kBtuh 20 6.0 1.0 2.4 Operation not recommended Operation not recommended10.0 2.7 6.2 14.0 5.1 11.8 1250 25.8 2.66 16.8 89.1 2.85 4.9 1500 26.7 2.69 17.5 86.5 2.91 4.4 30 6.0 1.0 2.3 Operation not recommended Operation not recommended 10.0 2.6 6.0 1250 30.0 2.74 20.6 92.2 3.21 4.9 1250 45.9 27.0 0.59 1.42 50.8 32.2 - 1500 31.0 2.77 21.6 89.2 3.28 4.5 1500 47.3 30.8 0.65 1.49 52.4 31.7 - 14.0 5.0 11.5 1250 31.0 2.74 21.7 93.0 3.32 5.1 1250 46.0 26.9 0.59 1.39 50.8 33.1 - 1500 32.1 2.77 22.6 89.8 3.39 4.6 1500 47.2 30.7 0.65 1.47 52.2 32.2 - 40 6.0 1.0 2.3 Operation not recommended Operation not recommended 10.0 2.5 5.9 1250 35.4 2.83 25.7 96.2 3.66 5.2 1250 47.3 27.7 0.59 1.56 52.6 30.2 - 1500 36.3 2.84 26.6 92.4 3.75 4.8 1500 48.7 31.5 0.65 1.64 54.3 29.7 - 14.0 4.8 11.1 1250 36.5 2.84 26.8 97.0 3.76 5.4 1250 47.4 27.6 0.58 1.53 52.6 31.0 - 1500 37.5 2.85 27.8 93.1 3.85 4.9 1500 48.7 31.4 0.65 1.61 54.2 30.3 - 50 6.0 0.9 2.2 1250 39.8 2.88 30.0 99.5 4.05 5.5 1250 48.4 28.0 0.58 1.81 54.6 26.7 1.8 1500 40.9 2.88 31.0 95.2 4.16 5.1 1500 49.8 31.8 0.64 1.91 56.3 26.1 1.9 10.0 2.5 5.7 1250 40.4 2.93 30.4 99.9 4.04 5.7 1250 48.5 28.3 0.58 1.75 54.5 27.8 1.7 1500 41.3 2.91 31.4 95.5 4.16 5.2 1500 50.0 32.1 0.64 1.83 56.2 27.3 1.8 14.0 4.7 10.8 1250 41.6 2.95 31.6 100.8 4.14 5.8 1250 48.7 28.3 0.58 1.71 54.5 28.4 1.5 1500 42.6 2.93 32.6 96.3 4.26 5.3 1500 50.1 32.1 0.64 1.80 56.2 27.9 1.7 60 6.0 0.9 2.1 1250 44.3 2.97 34.1 102.8 4.37 6.0 1250 46.7 27.4 0.59 2.02 53.6 23.1 2.5 1500 45.2 2.95 35.2 97.9 4.50 5.6 1500 48.1 31.0 0.64 2.12 55.3 22.7 2.7 10.0 2.4 5.5 1250 45.7 3.02 35.3 103.8 4.42 6.2 1250 46.9 27.7 0.59 1.96 53.6 23.9 2.4 1500 46.4 2.98 36.2 98.6 4.56 5.7 1500 48.3 31.3 0.65 2.05 55.3 23.6 2.5 14.0 4.5 10.4 1250 46.8 3.05 36.3 104.6 4.49 6.4 1250 47.1 27.7 0.59 1.92 53.6 24.5 2.2 1500 47.5 3.01 37.2 99.3 4.63 5.9 1500 48.5 31.3 0.65 2.01 55.3 24.2 2.4 70 6.0 0.9 2.0 1250 48.7 3.07 38.2 106.0 4.65 6.7 1250 45.9 27.8 0.61 2.29 53.7 20.1 3.6 1500 49.5 3.01 39.2 100.5 4.81 6.2 1500 47.3 31.1 0.66 2.38 55.4 19.9 3.8 10.0 2.3 5.3 1250 50.7 3.12 40.1 107.6 4.77 6.9 1250 46.1 28.0 0.61 2.22 53.7 20.8 3.3 1500 51.3 3.05 40.9 101.7 4.93 6.4 1500 47.6 31.5 0.66 2.32 55.5 20.5 3.6 14.0 4.4 10.1 1250 51.7 3.15 40.9 108.3 4.81 7.1 1250 46.4 28.1 0.61 2.17 53.8 21.4 3.1 1500 52.2 3.08 41.7 102.3 4.97 6.5 1500 47.8 31.6 0.66 2.27 55.6 21.1 3.4 80 6.0 0.9 2.0 1250 52.8 3.16 42.0 109.1 4.89 7.4 1250 43.9 26.8 0.61 2.58 52.7 17.0 4.9 1500 53.2 3.09 42.7 102.9 5.05 6.9 1500 45.2 29.9 0.66 2.67 54.3 16.9 5.2 10.0 2.2 5.1 1250 55.7 3.21 44.8 111.3 5.09 7.7 1250 44.2 27.0 0.61 2.52 52.8 17.6 4.6 1500 56.0 3.12 45.4 104.6 5.27 7.1 1500 45.6 30.3 0.66 2.62 54.5 17.4 5.0 14.0 4.2 9.8 1250 56.4 3.25 45.3 111.8 5.08 7.9 1250 44.5 27.2 0.61 2.48 53.0 18.0 4.3 1500 56.6 3.16 45.8 104.9 5.25 7.3 1500 45.9 30.5 0.66 2.57 54.7 17.9 4.7 90 6.0 0.8 1.9 1250 56.7 3.25 45.6 112.0 5.11 8.3 1250 40.6 25.4 0.63 2.92 50.6 13.9 6.6 1500 56.9 3.17 46.1 105.1 5.26 7.7 1500 41.8 28.2 0.67 3.00 52.1 13.9 7.0 10.0 2.1 5.0 1250 60.6 3.30 49.3 114.9 5.37 8.6 1250 41.1 25.7 0.62 2.85 50.8 14.4 6.1 1500 60.6 3.18 49.7 107.4 5.57 8.0 1500 42.3 28.6 0.68 2.95 52.4 14.3 6.6 14.0 4.1 9.4 1250 61.0 3.36 49.5 115.2 5.32 8.8 1250 41.4 25.9 0.63 2.82 51.0 14.7 5.7 1500 60.8 3.24 49.8 107.5 5.51 8.2 1500 42.7 28.8 0.67 2.90 52.6 14.7 6.3 100 6.0 0.8 1.8 Operation not recommended Operation not recommended 10.0 2.1 4.8 1250 39.4 25.7 0.65 3.26 50.5 12.1 8.0 1500 40.6 28.5 0.70 3.34 52.0 12.1 8.6 14.0 3.9 9.1 1250 39.8 26.1 0.66 3.21 50.7 12.4 7.4 1500 41.0 28.8 0.70 3.29 52.3 12.5 8.2 110 6.0 0.8 1.8 Operation not recommended 10.0 2.0 4.6 1250 35.4 24.3 0.69 3.69 48.0 9.6 10.1 1500 36.6 26.7 0.73 3.77 49.4 9.7 10.9 14.0 3.8 8.7 1250 35.9 24.7 0.69 3.64 48.3 9.9 9.4 1500 37.0 27.1 0.73 3.71 49.7 10.0 10.4 120 6.0 0.7 1.7 Operation not recommended 10.0 1.9 4.4 1250 33.1 24.4 0.74 4.19 47.4 7.9 12.5 1500 34.2 26.6 0.78 4.23 48.6 8.1 13.5 14.0 3.6 8.4 1250 33.7 24.9 0.74 4.14 47.8 8.1 11.6 1500 34.7 27.1 0.78 4.18 49.0 8.3 12.9 Multiple Flow Rates (for EWT) are shown in the table above. The lowest flow rate shown is used for geothermal open loop/well water systems with a minimum 50° F. The second flow rate shown is the minimum geothermal closed loop flow rate. The third flow rate shown is optimum for geothermal closed loop and the suggested flow rate for boiler tower applications. 39 5 SERIES 500R11 SPECIFICATION CATALOG NDZ064 - Performance Data NDZ064 - Dual Capacity High Speed (1800 cfm) EWT °F Flow GPM WPD HEATING - EAT 70°F COOLING - EAT 80/67 °F PSI FT Airflow CFM HC kBtuh Power kW HE kBtuh LAT °F COP HWC kBtuh Airflow CFM TC kBtuh SC kBtuh S/T Ratio Power kW HR kBtuh EER HWC kBtuh 20 8.0 1.8 4.2 Operation not recommended Operation not recommended12.0 3.8 8.8 16.0 6.5 15.1 1500 38.2 3.68 25.7 93.6 3.04 6.0 1800 39.2 3.85 26.0 90.1 2.98 5.4 30 8.0 1.8 4.1 Operation not recommended Operation not recommended 12.0 3.7 8.6 1500 44.1 3.69 31.5 97.2 3.50 6.3 1500 57.9 37.0 0.64 2.32 65.8 24.9 - 1800 45.3 3.93 31.9 93.3 3.38 5.8 1800 58.4 40.3 0.69 2.47 66.8 23.7 - 16.0 6.4 14.7 1500 44.7 3.79 31.8 97.6 3.46 6.5 1500 58.5 37.4 0.64 2.28 66.3 25.6 - 1800 45.8 3.97 32.2 93.5 3.38 5.9 1800 58.9 40.6 0.69 2.43 67.2 24.3 - 40 8.0 1.7 4.0 Operation not recommended Operation not recommended 12.0 3.6 8.3 1500 50.7 3.94 37.3 101.3 3.77 7.0 1500 60.2 38.0 0.63 2.67 69.3 22.5 - 1800 51.9 4.11 37.9 96.7 3.70 6.4 1800 61.1 41.4 0.68 2.83 70.7 21.6 - 16.0 6.2 14.2 1500 51.5 4.01 37.8 101.8 3.76 7.2 1500 60.8 38.4 0.63 2.62 69.7 23.2 - 1800 52.7 4.15 38.5 97.1 3.72 6.5 1800 61.6 41.7 0.68 2.79 71.1 22.1 - 50 8.0 1.7 3.8 1500 54.1 4.10 40.1 103.4 3.87 7.5 1500 61.1 38.3 0.63 3.12 71.8 19.6 3.4 1800 55.3 4.23 40.8 98.4 3.83 7.0 1800 62.4 41.7 0.67 3.32 73.7 18.8 3.6 12.0 3.5 8.1 1500 57.2 4.18 43.0 105.3 4.01 7.8 1500 61.8 38.7 0.63 3.06 72.2 20.2 3.2 1800 58.4 4.29 43.8 100.0 3.99 7.1 1800 63.0 42.1 0.67 3.25 74.1 19.4 3.5 16.0 6.0 13.8 1500 58.2 4.23 43.8 105.9 4.03 8.0 1500 62.4 39.1 0.63 3.00 72.6 20.8 3.0 1800 59.4 4.33 44.7 100.6 4.02 7.3 1800 63.6 42.4 0.67 3.19 74.5 19.9 3.3 60 8.0 1.6 3.7 1500 60.7 4.38 45.7 107.5 4.06 8.5 1500 59.7 38.0 0.64 3.37 71.2 17.7 4.2 1800 62.0 4.46 46.8 101.9 4.08 7.8 1800 61.2 41.3 0.67 3.58 73.5 17.1 4.4 12.0 3.4 7.8 1500 63.5 4.46 48.3 109.2 4.18 8.7 1500 60.3 38.3 0.64 3.30 71.6 18.3 3.9 1800 64.8 4.51 49.4 103.4 4.21 8.0 1800 61.9 41.7 0.67 3.51 73.9 17.7 4.2 16.0 5.8 13.4 1500 64.8 4.51 49.5 110.0 4.22 9.0 1500 60.9 38.7 0.64 3.24 72.0 18.8 3.6 1800 66.3 4.56 50.8 104.1 4.27 8.2 1800 62.5 42.1 0.67 3.45 74.3 18.1 4.0 70 8.0 1.6 3.6 1500 67.3 4.69 51.3 111.6 4.20 9.5 1500 60.2 38.3 0.64 3.74 73.0 16.1 5.2 1800 68.8 4.72 52.7 105.4 4.28 8.8 1800 62.1 41.6 0.67 3.99 75.7 15.6 5.5 12.0 3.3 7.5 1500 69.8 4.76 53.6 113.1 4.30 9.8 1500 60.8 38.7 0.64 3.67 73.4 16.6 4.9 1800 71.4 4.77 55.1 106.7 4.38 9.0 1800 62.8 42.0 0.67 3.90 76.1 16.1 5.3 16.0 5.6 12.9 1500 71.6 4.82 55.1 114.2 4.36 10.1 1500 61.4 39.1 0.64 3.61 73.7 17.0 4.5 1800 73.3 4.82 56.8 107.7 4.46 9.3 1800 63.4 42.5 0.67 3.84 76.5 16.5 5.0 80 8.0 1.5 3.5 1500 74.0 5.00 56.9 115.7 4.34 10.7 1500 56.7 37.0 0.65 4.06 70.6 14.0 6.6 1800 75.7 4.97 58.7 108.9 4.46 9.9 1800 58.8 40.2 0.68 4.33 73.6 13.6 7.0 12.0 3.2 7.3 1500 75.7 5.06 58.5 116.8 4.39 11.0 1500 57.3 37.3 0.65 3.98 70.9 14.4 6.2 1800 77.5 5.01 60.4 109.9 4.54 10.2 1800 59.4 40.6 0.68 4.24 73.9 14.0 6.7 16.0 5.4 12.5 1500 78.0 5.12 60.6 118.2 4.46 11.4 1500 57.9 37.8 0.65 3.91 71.2 14.8 5.7 1800 80.0 5.06 62.7 111.1 4.63 10.5 1800 60.1 41.0 0.68 4.17 74.3 14.4 6.4 90 8.0 1.4 3.3 1500 80.7 5.34 62.5 119.8 4.43 12.0 1500 52.2 35.7 0.68 4.35 67.0 12.0 8.3 1800 82.6 5.26 64.7 112.5 4.60 11.1 1800 54.5 38.7 0.71 4.64 70.3 11.8 8.8 12.0 3.0 7.0 1500 81.8 5.40 63.3 120.5 4.44 12.4 1500 52.8 36.0 0.68 4.27 67.4 12.4 7.7 1800 83.8 5.29 65.8 113.1 4.65 11.5 1800 55.0 39.1 0.71 4.54 70.5 12.1 8.4 16.0 5.2 12.0 1500 84.6 5.47 65.9 122.2 4.53 12.8 1500 53.3 36.4 0.68 4.19 67.6 12.7 7.2 1800 86.8 5.34 68.6 114.6 4.76 11.8 1800 55.6 39.5 0.71 4.47 70.9 12.4 8.0 100 8.0 1.4 3.2 Operation not recommended Operation not recommended 12.0 2.9 6.8 1500 51.3 35.1 0.68 4.71 67.4 10.9 9.6 1800 53.7 38.1 0.71 5.02 70.9 10.7 10.4 16.0 5.0 11.6 1500 51.8 35.5 0.68 4.63 67.6 11.2 8.9 1800 54.3 38.5 0.71 4.94 71.1 11.0 9.9 110 8.0 1.3 3.1 Operation not recommended 12.0 2.8 6.5 1500 45.4 32.1 0.71 5.04 62.6 9.0 11.8 1800 47.8 34.8 0.73 5.38 66.2 8.9 12.8 16.0 4.8 11.2 1500 45.8 32.4 0.71 4.95 62.7 9.2 10.9 1800 48.2 35.2 0.73 5.29 66.3 9.1 12.1 120 8.0 1.3 3.0 Operation not recommended 12.0 2.7 6.3 1500 44.2 32.6 0.74 5.56 63.1 7.9 14.2 1800 46.7 35.4 0.76 5.94 67.0 7.9 15.4 16.0 4.6 10.7 1500 44.6 33.0 0.74 5.46 63.2 8.2 13.2 1800 47.1 35.8 0.76 5.84 67.1 8.1 14.7 Multiple Flow Rates (for EWT) are shown in the table above. The lowest flow rate shown is used for geothermal open loop/well water systems with a minimum 50° F. The second flow rate shown is the minimum geothermal closed loop flow rate. The third flow rate shown is optimum for geothermal closed loop and the suggested flow rate for boiler tower applications. 40 5 SERIES 500R11 SPECIFICATION CATALOG NDZ072 - Performance Data NDZ072 - Dual Capacity Low Speed (1700 cfm) EWT °F Flow GPM WPD HEATING - EAT 70°F COOLING - EAT 80/67 °F PSI FT Airflow CFM HC kBtuh Power kW HE kBtuh LAT °F COP HWC kBtuh Airflow CFM TC kBtuh SC kBtuh S/T Ratio Power kW HR kBtuh EER HWC kBtuh 20 10.0 2.7 6.2 Operation not recommended Operation not recommended13.0 3.6 8.3 16.0 6.5 15.0 1400 31.5 3.37 20.0 90.8 2.74 5.8 1700 33.0 3.41 21.4 88.0 2.84 5.3 30 10.0 2.6 6.0 Operation not recommended Operation not recommended 13.0 3.4 7.9 1400 35.2 3.39 23.6 93.3 3.04 5.9 1400 49.5 30.2 0.61 1.79 55.6 27.6 - 1700 36.9 3.43 25.2 90.1 3.15 5.4 1700 51.2 34.7 0.68 1.91 57.7 26.8 - 16.0 6.4 14.8 1400 36.7 3.39 25.2 94.3 3.17 6.1 1400 49.5 30.2 0.61 1.72 55.4 28.7 - 1700 38.5 3.43 26.7 90.9 3.28 5.5 1700 51.0 34.7 0.68 1.85 57.3 27.6 - 40 10.0 2.6 6.0 Operation not recommended Operation not recommended 13.0 3.3 7.6 1400 41.4 3.49 29.5 97.4 3.47 6.3 1400 51.7 32.0 0.62 1.97 58.4 26.3 - 1700 43.2 3.50 31.2 93.5 3.62 5.8 1700 53.4 36.6 0.68 2.08 60.5 25.6 - 16.0 6.2 14.3 1400 42.8 3.50 30.9 98.3 3.59 6.5 1400 51.8 32.0 0.62 1.91 58.3 27.2 - 1700 44.7 3.51 32.7 94.4 3.73 5.9 1700 53.4 36.5 0.68 2.03 60.3 26.4 - 50 10.0 2.5 5.8 1400 46.2 3.53 34.2 100.6 3.84 6.6 1400 53.6 33.4 0.62 2.27 61.3 23.6 2.0 1700 48.3 3.49 36.4 96.3 4.05 6.1 1700 55.2 37.9 0.69 2.38 63.4 23.2 2.1 13.0 3.2 7.4 1400 46.9 3.57 34.8 101.0 3.85 6.8 1400 53.7 33.7 0.63 2.19 61.2 24.5 1.9 1700 48.8 3.55 36.7 96.6 4.03 6.3 1700 55.4 38.3 0.69 2.31 63.2 24.0 2.0 16.0 6.0 13.9 1400 48.3 3.59 36.1 101.9 3.94 7.0 1400 53.9 33.7 0.63 2.13 61.1 25.3 1.8 1700 50.4 3.57 38.2 97.4 4.13 6.4 1700 55.5 38.3 0.69 2.25 63.2 24.7 1.9 60 10.0 2.4 5.5 1400 51.4 3.64 39.0 104.0 4.13 7.3 1400 52.0 33.0 0.63 2.49 60.5 20.9 2.9 1700 53.6 3.57 41.4 99.2 4.40 6.7 1700 53.6 37.3 0.70 2.60 62.5 20.6 3.0 13.0 3.1 7.2 1400 52.9 3.68 40.3 105.0 4.21 7.5 1400 52.3 33.3 0.64 2.41 60.5 21.7 2.7 1700 55.0 3.62 42.6 99.9 4.45 6.9 1700 53.8 37.7 0.70 2.52 62.4 21.3 2.9 16.0 5.8 13.4 1400 54.1 3.72 41.4 105.8 4.26 7.7 1400 52.5 33.4 0.64 2.37 60.5 22.2 2.5 1700 56.2 3.65 43.8 100.6 4.51 7.1 1700 54.1 37.8 0.70 2.47 62.5 21.9 2.7 70 10.0 2.3 5.3 1400 56.7 3.77 43.8 107.5 4.40 8.0 1400 51.7 33.5 0.65 2.79 61.2 18.5 4.0 1700 59.0 3.66 46.5 102.1 4.72 7.4 1700 53.2 37.7 0.71 2.89 63.0 18.4 4.3 13.0 3.0 7.0 1400 58.9 3.81 45.8 108.9 4.52 8.3 1400 52.0 33.9 0.65 2.70 61.2 19.3 3.8 1700 61.2 3.70 48.5 103.3 4.84 7.7 1700 53.5 38.1 0.71 2.80 63.0 19.1 4.1 16.0 5.6 12.9 1400 59.9 3.87 46.7 109.6 4.54 8.5 1400 52.3 34.1 0.65 2.66 61.3 19.6 3.5 1700 62.2 3.76 49.4 103.9 4.86 7.9 1700 53.9 38.3 0.71 2.75 63.3 19.6 3.9 80 10.0 2.2 5.1 1400 61.1 3.87 47.9 110.4 4.63 9.0 1400 49.3 32.7 0.66 3.10 59.9 15.9 5.6 1700 63.3 3.73 50.6 104.5 4.97 8.3 1700 50.8 36.6 0.72 3.19 61.7 15.9 5.9 13.0 2.9 6.8 1400 64.3 3.92 50.9 112.5 4.81 9.2 1400 49.7 33.1 0.67 3.02 60.0 16.4 5.2 1700 66.6 3.76 53.8 106.3 5.19 8.5 1700 51.2 37.0 0.72 3.11 61.8 16.4 5.6 16.0 5.5 12.7 1400 65.0 3.97 51.5 113.0 4.80 9.5 1400 50.1 33.3 0.67 2.98 60.2 16.8 4.8 1700 67.3 3.82 54.2 106.6 5.16 8.8 1700 51.6 37.3 0.72 3.06 62.1 16.9 5.3 90 10.0 2.1 4.9 1400 65.6 3.99 52.0 113.4 4.82 10.0 1400 45.5 31.1 0.68 3.45 57.3 13.2 7.4 1700 67.8 3.82 54.7 106.9 5.20 9.3 1700 46.9 34.5 0.74 3.52 58.9 13.3 7.9 13.0 2.7 6.2 1400 69.8 4.04 56.0 116.2 5.07 10.3 1400 46.0 31.4 0.68 3.38 57.5 13.6 6.9 1700 72.2 3.84 59.1 109.3 5.51 9.6 1700 47.4 35.0 0.74 3.45 59.2 13.7 7.5 16.0 5.3 12.2 1400 70.3 4.10 56.3 116.5 5.03 10.6 1400 46.5 31.7 0.68 3.32 57.8 14.0 6.4 1700 72.5 3.91 59.1 109.5 5.43 9.9 1700 47.9 35.2 0.74 3.40 59.5 14.1 7.2 100 10.0 2.1 4.9 Operation not recommended Operation not recommended 13.0 2.6 6.0 1400 44.1 31.3 0.71 3.82 57.1 11.6 9.0 1700 45.5 34.7 0.76 3.86 58.7 11.8 9.8 16.0 5.0 11.6 1400 44.7 31.7 0.71 3.76 57.5 11.9 8.4 1700 46.0 35.1 0.76 3.81 59.0 12.1 9.3 110 10.0 2.0 4.6 Operation not recommended 13.0 2.6 6.0 1400 39.2 29.4 0.75 4.26 53.7 9.2 11.4 1700 40.5 32.4 0.80 4.28 55.1 9.5 12.4 16.0 4.8 11.1 1400 39.9 29.8 0.75 4.21 54.2 9.5 10.6 1700 41.0 32.8 0.80 4.23 55.4 9.7 11.8 120 10.0 1.9 4.4 Operation not recommended 13.0 2.4 5.5 1400 36.6 28.6 0.78 4.81 53.0 7.6 14.1 1700 38.0 31.4 0.83 4.79 54.3 7.9 15.3 16.0 4.6 10.6 1400 37.4 29.1 0.78 4.73 53.5 7.9 13.1 1700 38.4 31.9 0.83 4.72 54.5 8.1 14.6 Multiple Flow Rates (for EWT) are shown in the table above. The lowest flow rate shown is used for geothermal open loop/well water systems with a minimum 50° F. The second flow rate shown is the minimum geothermal closed loop flow rate. The third flow rate shown is optimum for geothermal closed loop and the suggested flow rate for boiler tower applications. 41 5 SERIES 500R11 SPECIFICATION CATALOG NDZ072 - Performance Data NDZ072 - Dual Capacity High Speed (2200 cfm) EWT °F Flow GPM WPD HEATING - EAT 70°F COOLING - EAT 80/67 °F PSI FT Airflow CFM HC kBtuh Power kW HE kBtuh LAT °F COP HWC kBtuh Airflow CFM TC kBtuh SC kBtuh S/T Ratio Power kW HR kBtuh EER HWC kBtuh 20 12.0 3.8 8.8 Operation not recommended Operation not recommended15.0 5.8 13.4 18.0 8.6 19.9 1850 44.0 4.15 29.9 92.0 3.11 7.7 2200 45.7 4.41 30.6 89.2 3.03 6.9 30 12.0 3.7 8.5 Operation not recommended Operation not recommended 15.0 5.7 13.2 1850 51.0 4.31 36.3 95.5 3.47 8.1 1850 63.3 38.6 0.61 2.51 71.9 25.2 - 2200 52.8 4.58 37.2 92.2 3.38 7.4 2200 64.5 42.0 0.65 2.67 73.6 24.2 - 18.0 8.1 18.7 1850 51.5 4.35 36.6 95.8 3.47 8.3 1850 63.9 39.3 0.61 2.47 72.4 25.9 - 2200 53.4 4.63 37.6 92.5 3.38 7.6 2200 65.1 42.3 0.65 2.62 74.1 24.8 - 40 12.0 3.6 8.3 Operation not recommended Operation not recommended 15.0 5.6 12.9 1850 59.2 4.57 43.6 99.6 3.79 8.9 1850 65.8 41.1 0.62 3.03 76.2 21.7 - 2200 61.2 4.79 44.9 95.8 3.74 8.2 2200 67.1 44.7 0.67 3.22 78.1 20.8 - 18.0 8.2 18.9 1850 60.0 4.63 44.2 100.0 3.80 9.2 1850 66.5 41.9 0.63 2.98 76.7 22.3 - 2200 62.1 4.84 45.6 96.1 3.76 8.4 2200 67.8 45.1 0.66 3.17 78.6 21.4 - 50 12.0 3.5 8.1 1850 63.0 4.77 46.7 101.5 3.87 9.6 1850 67.0 42.8 0.64 3.68 79.6 18.2 3.8 2200 65.1 4.94 48.3 97.4 3.87 8.9 2200 68.4 46.5 0.68 3.91 81.8 17.5 4.0 15.0 5.5 12.7 1850 66.5 4.86 50.0 103.3 4.02 9.9 1850 67.7 43.2 0.64 3.61 80.0 18.8 3.5 2200 68.7 5.02 51.6 98.9 4.02 9.1 2200 69.1 47.0 0.68 3.83 82.1 18.0 3.8 18.0 7.7 17.8 1850 67.7 4.92 51.0 103.9 4.04 10.2 1850 68.4 44.1 0.64 3.55 80.5 19.3 3.3 2200 70.0 5.07 52.7 99.4 4.05 9.4 2200 69.8 47.4 0.68 3.77 82.6 18.5 3.7 60 12.0 3.4 7.9 1850 70.8 5.08 53.5 105.4 4.09 10.8 1850 65.8 42.8 0.65 3.91 79.2 16.8 4.6 2200 73.1 5.18 55.4 100.8 4.14 10.0 2200 67.2 46.3 0.69 4.16 81.4 16.2 4.9 15.0 5.2 12.0 1850 74.0 5.17 56.3 107.0 4.20 11.2 1850 66.5 43.3 0.65 3.83 79.6 17.4 4.3 2200 76.4 5.25 58.4 102.1 4.26 10.3 2200 67.8 46.8 0.69 4.07 81.7 16.7 4.7 18.0 7.5 17.3 1850 75.6 5.23 57.8 107.8 4.24 11.5 1850 67.2 43.9 0.65 3.77 80.1 17.9 4.0 2200 78.1 5.30 60.0 102.9 4.32 10.5 2200 68.6 47.3 0.69 4.01 82.2 17.1 4.5 70 12.0 3.3 7.6 1850 78.7 5.39 60.3 109.4 4.28 12.2 1850 65.8 43.7 0.66 4.35 80.7 15.1 5.8 2200 81.2 5.43 62.7 104.2 4.38 11.2 2200 67.2 47.0 0.70 4.63 83.0 14.5 6.2 15.0 5.0 11.6 1850 81.5 5.48 62.8 110.8 4.36 12.5 1850 66.4 44.1 0.66 4.26 81.0 15.6 5.4 2200 84.1 5.49 65.4 105.4 4.49 11.6 2200 67.8 47.4 0.70 4.53 83.3 15.0 5.9 18.0 7.0 16.2 1850 83.6 5.55 64.7 111.8 4.42 12.9 1850 67.2 44.6 0.66 4.19 81.5 16.0 5.0 2200 86.4 5.55 67.5 106.4 4.56 11.9 2200 68.5 48.0 0.70 4.46 83.8 15.4 5.6 80 12.0 3.2 7.4 1850 85.7 5.75 66.1 112.9 4.36 13.7 1850 62.9 42.5 0.68 4.68 78.9 13.5 7.3 2200 88.5 5.71 69.0 107.2 4.54 12.7 2200 64.3 45.9 0.72 4.98 81.2 12.9 7.8 15.0 4.8 11.1 1850 87.7 5.83 67.8 113.9 4.41 14.1 1850 63.6 42.9 0.68 4.58 79.2 13.9 6.9 2200 90.5 5.75 70.9 108.1 4.61 13.0 2200 64.9 46.4 0.71 4.87 81.5 13.3 7.4 18.0 6.7 15.5 1850 90.4 5.91 70.2 115.2 4.48 14.5 1850 64.3 43.6 0.68 4.50 79.6 14.3 6.4 2200 93.4 5.82 73.5 109.3 4.71 13.4 2200 65.6 46.9 0.71 4.79 81.9 13.7 7.1 90 12.0 3.0 6.9 1850 92.8 6.12 71.9 116.4 4.44 15.4 1850 58.8 40.4 0.69 4.89 75.5 12.0 9.2 2200 95.8 6.00 75.4 110.3 4.68 14.2 2200 60.1 43.9 0.73 5.21 77.8 11.5 9.8 15.0 4.5 10.4 1850 94.1 6.19 73.0 117.1 4.45 15.8 1850 59.4 40.8 0.69 4.79 75.7 12.4 8.6 2200 97.1 6.03 76.6 110.9 4.72 14.7 2200 60.6 44.3 0.73 5.10 78.0 11.9 9.3 18.0 6.5 15.0 1850 97.3 6.27 75.9 118.7 4.54 16.3 1850 60.1 41.6 0.69 4.71 76.1 12.8 8.0 2200 100.5 6.09 79.7 112.3 4.84 15.1 2200 61.3 44.7 0.73 5.02 78.4 12.2 8.9 100 12.0 2.9 6.7 Operation not recommended Operation not recommended 15.0 4.4 10.2 1850 57.0 40.2 0.71 5.28 75.0 10.8 10.7 2200 58.1 43.4 0.75 5.62 77.3 10.3 11.6 18.0 6.3 14.6 1850 57.6 40.8 0.71 5.19 75.3 11.1 9.9 2200 58.8 43.9 0.75 5.52 77.6 10.6 11.0 110 12.0 2.8 6.5 Operation not recommended 15.0 4.3 9.9 1850 50.8 37.2 0.73 5.52 69.7 9.2 13.1 2200 51.9 40.0 0.77 5.87 71.9 8.8 14.2 18.0 6.1 14.1 1850 51.4 37.6 0.73 5.43 69.9 9.5 12.2 2200 52.5 40.4 0.77 5.77 72.2 9.1 13.5 120 12.0 2.7 6.2 Operation not recommended 15.0 4.1 9.5 1850 48.2 36.1 0.75 6.06 68.8 8.0 15.8 2200 49.1 39.0 0.79 6.45 71.1 7.6 17.2 18.0 5.8 13.4 1850 48.7 36.5 0.75 5.96 69.0 8.2 14.7 2200 49.7 39.2 0.79 6.32 71.2 7.9 16.3 Multiple Flow Rates (for EWT) are shown in the table above. The lowest flow rate shown is used for geothermal open loop/well water systems with a minimum 50° F. The second flow rate shown is the minimum geothermal closed loop flow rate. The third flow rate shown is optimum for geothermal closed loop and the suggested flow rate for boiler tower applications. 42 5 SERIES 500R11 SPECIFICATION CATALOG Wiring Schematics Split Wiring Schematic - 208-230/60/1 4/3/1397P840-21 CC T2 T1 Compressor C R SBlue G L1L2 Black 208-230/60/1Unit Power Supply Violet(7) RedTan(6) Black(3) Black(2) Cap Ext Pump 1/2 hp Total 208-230/60/1 Pump G 1 2 PB1 1 2 Pump Violet(8) Circuit Breaker Circuit Breaker Optional InternalHot Water Generation Pump 1 5A 5A DHW Pump PurpleHot Water Limit Switch130°F Blue 1 2 3 Blue Cabinet HW Switch Water Solenoid (see Open Loop Groundwater Systems section) Aurora LED Flash Codes Status LED (LED3, Green) Status LED (LED1, Green)Configuration LED (LED2, Yellow) Fault LED (LED3, Red) Random Start Delay (Alternating Colors) Fast FlashFast Flash Fast Flash 1 second on and 1 second off 100 milliseconds on and 100 milliseconds off 100 milliseconds on and 400 milliseconds off with a 2 second pause before repeating Slow Flash Fast Flash Flash Code Normal Mode Control is Non-Functional Test Mode Lockout Active Dehumidification Mode Future Use Future Use Load Shed ESD OFF ON Slow Flash Fast Flash Flash Code 2 Flash Code 3 Flash Code 6 Flash Code 4 Flash Code 5 Future Use Flash Code 7 Configuration LED (LED2, Yellow) No Software Overide OFFDIP Switch Overide Slow Flash Fault LED (LED1, Red)Normal Mode Input Fault Lockout High Pressure Lockout Low Pressure Lockout Future Use Freeze Detection – FP1 Reserved Condensate Overflow Lockout Over/Under Voltage Shutdown Future Use Future UseFP1 and FP2 Sensor Error Flash Code 1 OFF Flash Code 2 Flash Code 3 Flash Code 4 Flash Code 5 Flash Code 8 Flash Code 6 Flash Code 7 Flash Code 9 Flash Code 10Flash Code 11 DESCRIPTION SW2-4 SW2-5 Cycle with Blower ON ON Cycle with Compressor OFF OFF Water Valve Slow Opening ON OFFCycle with Comm. T-stat Hum Cmd OFF ON ABC SW2 Accessory Relay RVCCHP Black Black Blue Blue LP TYellow Yellow FP1 Orange Orange RV Black(15) Violet(14) Green(11) UltraTech Dual Capacity Units Only RCP CS Blue(16)Blue(18) AID Tool CFM P13 P4 SW1 P5JW2P9 LO O/B Y2 W DH P8 P7 RS485 NET RS485 NET P6 RS485 EXP P3 SW2 On Future Use L Output TypeCC – Dual/SingleAcc – Dip 5Acc – Dip 4RV – B/OFP2 – 15°F/30°FFP1 – 15°F/30°F Com1LED5Com2LED5 Test Mode F1-3A P1 C PWM 12345678 ALM ALG ACC COM ACC NO ACC NC R C G Y1 EH2CEH1CCOCR-+C R-+ Off Fault LED1 R Status LED3 ConfigLED2 CC2 CC F C RFFGCCCCGCC2HICC2LOCC2G REVREV FP1 FP1 FP2 FP2 LPS LPSHPSHPS Aurora Base Control (ABC)K1-RV RelayK2-CC Relay K3-CC2 RelayK4-Fan RelayK5-Alarm Relay K6-Acc Relay F R C CCGY1C R ES LS P2 EH1 YGG G Event Normal Mode Test Mode Random Start Delay Compressor On DelayCompressor Minimum On Time Compressor Short Cycle Delay Blower Off DelayFault Recognition Delay – High Pressure Start-Up Bypass – Low Pressure Fault Recognition Delay – Low Pressure Start-Up Bypass – Low Water Coil Limit Fault Recognition Delay – Low Water Coil Limit Fault Recognition Delay – Condensate Overflow Thermostat Call Recognition Time Less than 1 second 5 to 80 seconds 1 second 5 seconds < 1 second 30 seconds 2 secondsLess than 1 second 2 minutes 5 seconds 4 minutes 15 seconds 2 minutes 2 minutes 30 seconds 30 seconds 30 seconds 30 seconds 30 seconds 30 seconds 30 seconds 30 seconds 2 seconds 2 seconds Aurora Timing Events Water Valve Slow Open Delay 90 seconds90 seconds Notes 1 – Field installed SPST relay required for duel fuel applications Y1 Y2 O R C L C R Fossil Fuel Furnace Thermostat 24 VAC Common Common 24 VAC Fault Signal Reversing Valve 2nd Stage Compressor 1st Stage Compressor Y1 Y2 O R C LO Split GGFan W W Auxiliary Heat Relay Duel Fuel Wiring DiagramUsing Field Installed Relay Note 1: Field installed SPST dual fuel relay (Required for dual fuel installation) Auxiliary Heat Relay P2 P1 Auxiliary Heat Relay ES = chassis CC2 FactoryFault ALGALMLSESACC cStatus AURORA BASE CONTROL™ RV – K1 CC2CC – K2 CC Hi – K3 Fan – K4 Alarm – K5 Acc – K6 ACC noACC ncO/BCRLOGY1Y2WDH3A-FuseO/BCRLOGY1Y2WDHLOG HICCGCCFGFR HPHPLP FP2FP2FP1 REVREV CFMPWMECM PWM FactoryFactory Fan Connection RR CCCC R (-) (+)RS 485EH2CEH1CCO (+)(-)RCRS485 ExpFactoryCom1 Com2 Config G G G YR SW1 Test FP1 – 15oF/30oF JW2 - Alarm P11 P5 P2 P1 P8 P7 P9 P6 P3 SW2 P13P4 FP2 – 15oF/30oF RV – B/O ACC – Dip 4 ACC – Dip 5 CC – Dual/Single L – Pulse/Continuous Reheat/Normal Factory UseField ConnectionsField ConnectionsCLP FP1 F CC G Y1 1 2 3 4 5 6 7 8 Off On N/A RS485 NETEH1LED1 LED3 LED2 LED4 LED5 Current Transducer (CT) Thermistor Light emitting diode - Green Relay coil Capacitor w/ bleed resistor Switch - Condensate overflow Switch - High pressure Switch - Low pressure Polarized connector Factory Low voltage wiring Factory Line voltage wiring Field low voltage wiring Field line voltage wiring Optional block DC Voltage PCB traces Junction Quick connect terminal Wire nut Field wire lug Ground Fuse CC -CO -K5 -K6 -CR3 -CR4 - F1 and F2 - WCL - HE -HP - LP - PB1, PB2 - PS -RV -SW1 -SW1 - SW2 - TS - Compressor ContactorCondensate overflow sensorDHW pump relayLoop pump relay Fuses Water Coil Limit Sensor Heater elementHigh pressure switch Low pressure switch Power blocksPower stripReversing Valve coilDIP package 5 position AXBTEST MODE ABC Board DIP package 8 position ABC Board Thermal limit switch Legend Relay Contacts-N.O., N.C. G T 132P L1 PSC Fan Speed Relay PSC Fan Power Relay HWL -Hot water limit sensorSC -Start ContactorStart RelaySR - CS - Compressor Solenoid Breaker Freeze protection sensorFP1 - 43 5 SERIES 500R11 SPECIFICATION CATALOG Wiring Schematics cont. Split Wiring Schematic with IntelliStart - 208-230/60/1 4/3/1397P840-22 CC T2 T1 Compressor C R SBlue G L1L2208-230/60/1Unit Power Supply Violet(7) Tan(6) Black(3) Black(2) Cap Ext Pump 1/2 hp Total 208-230/60/1 Pump G 1 2 PB1 1 2 Pump Violet(8) Circuit Breaker Circuit Breaker Optional InternalHot Water Generation Pump 1 5A 5A DHW Pump PurpleHot Water Limit Switch130°F Blue 1 2 3 Blue CabinetHW Switch Run Winding Active Start Common IntelliStart Black Blue PinkBlack Red Water Solenoid (see Open Loop Groundwater Systems section) Aurora LED Flash Codes Status LED (LED3, Green) Status LED (LED1, Green) Configuration LED (LED2, Yellow) Fault LED (LED3, Red) Random Start Delay (Alternating Colors) Fast Flash Fast Flash Fast Flash 1 second on and 1 second off 100 milliseconds on and 100 milliseconds off 100 milliseconds on and 400 milliseconds off with a 2 second pause before repeating Slow Flash Fast Flash Flash Code Normal Mode Control is Non-FunctionalTest Mode Lockout Active Dehumidification Mode Future Use Future Use Load Shed ESD OFF ON Slow Flash Fast Flash Flash Code 2 Flash Code 3 Flash Code 6 Flash Code 4 Flash Code 5 Future Use Flash Code 7 Configuration LED (LED2, Yellow) No Software Overide OFF DIP Switch Overide Slow Flash Fault LED (LED1, Red) Normal Mode Input Fault LockoutHigh Pressure Lockout Low Pressure Lockout Future Use Freeze Detection – FP1 Reserved Condensate Overflow Lockout Over/Under Voltage Shutdown Future UseFuture Use FP1 and FP2 Sensor Error Flash Code 1 OFF Flash Code 2 Flash Code 3 Flash Code 4 Flash Code 5 Flash Code 8 Flash Code 6 Flash Code 7 Flash Code 9Flash Code 10 Flash Code 11 DESCRIPTION SW2-4 SW2-5 Cycle with Blower ON ON Cycle with Compressor OFF OFF Water Valve Slow Opening ON OFFCycle with Comm. T-stat Hum Cmd OFF ON ABC SW2 Accessory Relay RVCCHP Black Black Blue Blue LP TYellow Yellow FP1 Orange Orange RV Black(15) Violet(14) Green(11) UltraTech Dual Capacity Units Only RCP CS Blue(16)Blue(18) AID Tool CFM P13 P4 SW1 P5JW2P9 LO O/B Y2 W DH P8 P7 RS485 NET RS485 NET P6 RS485 EXP P3 SW2 On Future Use L Output TypeCC – Dual/SingleAcc – Dip 5Acc – Dip 4RV – B/OFP2 – 15°F/30°FFP1 – 15°F/30°F Com1LED5Com2LED5 Test Mode F1-3A P1 C PWM 12345678 ALM ALG ACC COM ACC NO ACC NC R C G Y1 EH2CEH1CCOCR-+C R-+ Off FaultLED1 R StatusLED3 ConfigLED2 CC2 CC F C R F FG CC CCG CC2HICC2LOCC2G REVREV FP1 FP1 FP2 FP2 LPS LPSHPSHPS Aurora Base Control(ABC)K1-RV RelayK2-CC Re lay K3-CC2 Re layK4-Fan RelayK5-Alarm Relay K6-Acc Relay F R C CCGY1C R ES LS P2 EH1 YGG G Event Normal Mode Test Mode Random Start Delay Compressor On Delay Compressor Minimum On Time Compressor Short Cycle Delay Blower Off DelayFault Recognition Delay – High Pressure Start-Up Bypass – Low Pressure Fault Recognition Delay – Low Pressure Start-Up Bypass – Low Water Coil Limit Fault Recognition Delay – Low Water Coil Limit Fault Recognition Delay – Condensate Overflow Thermostat Call Recognition Time Less than 1 second 5 to 80 seconds 1 second 5 seconds < 1 second 30 seconds 2 secondsLess than 1 second 2 minutes 5 seconds 4 minutes 15 seconds 2 minutes 2 minutes 30 seconds 30 seconds 30 seconds 30 seconds 30 seconds 30 seconds 30 seconds 30 seconds 2 seconds 2 seconds Aurora Timing Events Water Valve Slow Open Delay 90 seconds90 seconds Notes 1 – Field installed SPST relay required for duel fuel applications Y1 Y2 O R C L C R Fossil Fuel Furnace Thermostat 24 VAC Common Common 24 VAC Fault Signal Reversing Valve 2nd Stage Compressor 1st Stage Compressor Y1 Y2 O R C LO Split GGFan W W Auxiliary Heat Relay Duel Fuel Wiring Diagram Using Field Installed Relay Note 1: Field installed SPST dual fuel relay (Required for dual fuel installation) Auxiliary Heat Relay P2 P1 Auxiliary Heat Relay ES = chassis CC2 FactoryFault ALGALMLSESACC cStatus AURORA BASE CONTROL™ RV – K1 CC2CC – K2 CC Hi – K3 Fan – K4 Alarm – K5 Acc – K6 ACC noACC ncO/BCRLOGY1Y2WDH3A-FuseO/BCRLOGY1Y2WDHLO G HICCGCCFGFR HPHPLP FP2FP2FP1 REVREV CFMPWMECM PWM FactoryFactory Fan Connection RR CCCC R (-) (+)RS 485EH2CEH1CCO (+)(-)RCRS485 ExpFactoryCom1 Com2 Config G G G YR SW1 Test FP1 – 15oF/30oF JW2 - Alarm P11 P5 P2 P1 P8 P7 P9 P6 P3 SW2 P13P4 FP2 – 15oF/30oF RV – B/O ACC – Dip 4 ACC – Dip 5 CC – Dual/Single L – Pulse/Continuous Reheat/Normal Factory UseField ConnectionsField ConnectionsCLP FP1 F CC G Y1 1 2 3 4 5 6 7 8 Off On N/A RS485 NETEH1LED1 LED3 LED2 LED4 LED5 Current Transducer (CT) Thermistor Light emitting diode - Green Relay coil Capacitor w/ bleed resistor Switch - Condensate overflow Switch - High pressure Switch - Low pressure Polarized connector Factory Low voltage wiringFactory Line voltage wiringField low voltage wiringField line voltage wiringOptional blockDC Voltage PCB tracesJunction Quick connect terminal Wire nut Field wire lug Ground Fuse CC -CO -K5 -K6 -CR3 -CR4 - F1 and F2 - WCL - HE -HP - LP - PB1, PB2 - PS - RV - SW1 - SW1 - SW2 - TS - Compressor ContactorCondensate overflow sensorDHW pump relayLoop pump relay Fuses Water Coil Limit Sensor Heater elementHigh pressure switch Low pressure switch Power blocks Power strip Reversing Valve coil DIP package 5 position AXB TEST MODE ABC Board DIP package 8 position ABC Board Thermal limit switch Legend Relay Contacts- N.O., N.C. G T 132P L1 PSC Fan Speed RelayPSC Fan Power Relay HWL -Hot water limit sensorSC -Start ContactorStart RelaySR - CS - Compressor Solenoid Breaker Freeze protection sensorFP1 - 44 5 SERIES 500R11 SPECIFICATION CATALOG Engineering Guide Specifi cations General Furnish and install WaterFurnace Water Source Heat Pumps, as indicated on the plans. The geothermal heating/cooling units shall be reverse cycle split system configuration designed for use with DX heating and cooling coils. Units shall be AHRI/ISO 13256-1 certified and listed by a nationally recognized safety-testing laboratory or agency, such as ETL Testing Laboratory. Each unit shall be computer run-tested at the factory with conditioned water and operation verified to catalog data. Each unit shall be mounted on a pallet and shipped in a corrugated box or stretch-wrapped. The units shall be designed to operate with entering liquid temperature between 20°F and 120°F [-6.7°C and 48.9°C]. Casing and Cabinet The cabinet shall be fabricated from heavy-gauge galvanized steel and finished with corrosion-resistant powder coating. This corrosion protection system shall meet the stringent 1000 hour salt spray test per ASTM B117. The interior shall be insulated with 1/2-inch thick, multi- density, cleanable aluminum foil coated glass fiber with edges sealed or tucked under flanges. Standard cabinet panel insulation must meet NFPA 90A requirements, air erosion and mold growth limits of UL-181, stringent fungal resistance test per ASTM-C1071 and ASTM G21, and shall meet zero level bacteria growth per ASTM G22. Unit insulation must meet these stringent requirements or unit(s) will not be accepted. Refrigerant Circuit All units shall contain a sealed refrigerant circuit including a hermetic motor-compressor, thermostatic expansion valve, reversing valve, coaxial tube water-to-refrigerant heat exchanger, compressor discharge muffler, accumulator, and service ports. Compressors shall be high-efficiency scroll single speed or dual capacity type designed for heat pump duty and mounted on rubber vibration isolators. Compressor motors shall be single-phase PSC with overload protection. The coaxial water-to-refrigerant heat exchanger shall be designed for low water pressure drop and constructed of a convoluted copper (cupronickel option) inner tube and a steel outer tube. Refrigerant to water heat exchangers shall be of copper inner water tube and steel refrigerant outer tube design, rated to withstand 600 psig (4135 kPa) working refrigerant pressure and 450 psig (3101 kPa) working water pressure. The thermostatic expansion valve shall provide proper superheat over the entire liquid temperature range with minimal “hunting.” All units shall have the source coaxial tube refrigerant- to-water heat exchanger and the optional hot water generator coil coated with ThermaShield. Refrigerant suction lines shall be insulated to prevent condensation at low liquid temperatures. Electrical A control box shall be located within the unit compressor compartment and shall contain a 2 pole compressor contactor, circuit breakers for protecting loop pumps, terminal block for thermostat wiring, and solid-state controller for complete unit operation. Electromechanical operation WILL NOT be accepted. Units shall be name- plated for use with time delay fuses or HACR circuit breakers. Unit controls shall be 24 volt and provide heating or cooling as required by the remote thermostat/sensor. An Aurora, a microprocessor-based controller, interfaces with a multi-stage electronic thermostat to monitor and control unit operation shall be provided. The control shall provide operational sequencing, high and low pressure switch monitoring, freeze detection, hot water limit thermistor sensing, lockout mode control, hot water and loop pump control, LED status and fault indicators, fault memory, field selectable options, and accessory output. The Lockout signal output shall have a pulsed option so that DDC systems can read specific lockout conditions from the control. A detachable terminal block with screw terminals will be provided for field control wiring. All units shall have knockouts for entrance of low and line voltage wiring. The control box shall be harness plug wired for easy removal. An optional Aurora Interface Diagnostic (AID) Tool shall communicate with the Aurora control allowing quick and easy access to setup, monitoring, and troubleshooting of any Aurora control. The device shall include the features of fault description and history, manual operation capability, sensor readings, timings, and other diagnostic tools. Optional IntelliStart® (compressor Soft Starter) shall be factory installed for use in applications that require low starting amps, reduced compressor start-up noise, off-grid, and improved start-up behavior. IntelliStart shall reduce normal starting current by 60% on 208/60/1 units. Piping Supply and return water connections shall be 1 in. [25.4 mm] FPT brass swivel fittings, which provide a union and eliminate the need for pipe wrenches and sealants when making field connections. The optional hot water generator shall have sweat type connections. All water piping shall be insulated to prevent condensation at low liquid temperatures. 45 5 SERIES 500R11 SPECIFICATION CATALOG Engineering Guide Specifi cations cont. Options and Accessories Cupronickel Heat Exchanger An optional cupronickel water-to-refrigerant heat exchanger shall be provided. Hot Water Generator An optional ThermaShield coated heat reclaiming hot water generator coil of vented double-wall copper construction suitable for potable water shall be provided. The coil and hot water circulating pump shall be factory mounted inside the unit with integral electronic high limit temperature monitoring and external on/off switch. Thermostat (field-installed) A multi-stage auto-changeover electronic digital thermostat shall be provided. The thermostat shall offer three heating and two cooling stages with precise temperature control. An OFF-HEAT-AUTO-COOL-EMERG system switch, OFF-AUTO blower switch, and indicating LEDs shall be provided. The thermostat shall display in °F or °C. The thermostat shall be a traditional 24 VAC type. Flow Center (field-installed) A self-contained module shall provide all liquid flow, fill and connection requirements for ground source closed loop systems up to 20 gpm. The pumps shall be wired to a power block located in the nearest unit. The heat pump units shall contain low voltage pump slaving control so that two units may share one flow center. 46 5 SERIES 500R11 SPECIFICATION CATALOG Pages: Description:Date: By: All First Published 09 Oct 2013 DS Revision Guide Manufactured by WaterFurnace International, Inc. 9000 Conservation Way Fort Wayne, IN 46809 www.waterfurnace.com ©2013 WaterFurnace International, Inc., 9000 Conservation Way, Fort Wayne, IN 46809-9794. WaterFurnace has a policy of continual product research and development and reserves the right to change design and specifi cations without notice. SC2503SN 10/13 CUS ISO 17025 Accredited