32C-149 263-271 Pleasant St permit application 2012-05-02PR'M kR1 d)JJT~l-1> 0 c:..
File # BP-20l2-0950 ~\l~ IX.IS\\"'~
APPLICANT/CONTACT PERSON TEAGNO CONSTRUCTION INC
ADDRESS/PHONE 228 TRIANGLE ST AMHERST (413) 549-0803
PROPERTY LOCATION 263 -271 PLEASANT ST
MAP 32CPARCEL 149 001 ZONE CB(lOO)l
THIS SECTION FOR OFFICIAL USE ONLY:
PERMIT APPLICATION CHECKLIST
ENCLOSED REQUIRED DATE
ZONING FORM FILLED OUT
Fee Paid
Building Pennit Filled out ,1%tjJ~
TypeofConstruction: REPLACE FAILING BRICK ON EASTERN END, REPAIR & REINFORCE
FOUNDATION & REPLACE STOREFRONTS
New Construction
Non Structural interior renovations
Addition to Existing
Accessory Structure
Buildin Plans Included:
Owner/ Statement or License 034716
3 sets of Plans I Plot Plan
THE FOLLOWING ACTION HAS BEEN TAKEN ON TIDS APPLICATION BASED ON
INFORMATION PJlESENTED:
__Approved _'_1/_ AAddditional pennits required (see below)
PLANNING BOARD PERMIT REQUIRED UNDER:§ _________
Intermediate Project: ___Site Plan AND/OR ____Special Pennit With Site Plan
Major Project: Site Plan AND/OR Special Pennit With Site Plan
WNING BOARD PERMIT REQUIRED UNDER:
Finding'-____ Special _.......________ Variance*____
__----'Received & Recorded at Registry ofDeeds ProofEnclosed'--____
__Other Pennits Required:
___Curb Cut from DPW ___Water Availability ___Sewer Availability
__---'Septic Approval Board ofHealth ____Well Water Potability Board ofHealth
___Pennit from Conservation Commission _-,0~Pennit from CB Architecture Committee
---Pennit from Elm Street Commission ____,Pennit DPW Storm Water Management
__-,Demolition Delay
Signature ofBuildm'gOffiCial Date /'
Note: Issuance of a Zoning permit does not relieve a applicant's burden to comply with all zoning
requirements and obtain all required permits from Board of Health, Conservation Commission, Department
of public works and other applicable permit granting authorities.
*Variances are granted only to those applicants who meet the strict standards ofMGL 40A. Contact Office of
Planning & Development for more information.
Versionl.7 Commercial Buildin
City of Northampton
,--,--..,.-"..----~--1juilding Department
DEPt OF BUILDING INSPECTIONS
HECi.~" ,'::0 212 Main Street Sew(3rlSeptiq t\vaila,b,iHty,..;.'='i..;,.'____.-'--'---.,...,-.,.'-,..;.,..;.--,.,..
Room 100 Water~II.Avail~biUty-:-:'..;,.~'..,-'"'...,.'.,...;'-'7'~----,.,==~-
22mI? N rthampton, MA 01060 TvJ~Sets()fSfr ....
pnone 41 587-1240 Fax 413-587-1272 PlotJSite:F'lan~ .othe~~s~ecl~'···"
, REPAIR, RENOVATE, CHANGE THE USE OR OCCUPANCY OF, OR DEMOLISH ANY BUIL.DING
OTHER THAN A ONE OR TWO FAMIL. Y DWEL.LlNG
, ' <-..: --.'
StC}tus of Permit:
Curb CuttP~i\lew,~ie~rmit_':;~~~-:-c-'--,-.,.'-_""';
SECTION 1 -SITE INFORMATION
This section to be completed by office
Map L.ot Unit
Zone Overlay District
CB District
SECTION 2 -PROPERTY OWNERSHIP/AUTHORIZED AGENT
Item
1. Building
2. Electrical
3. Plumbing
4. Mechanical (HVAC)
5. Fire Protection
6. Total (1 + 2 + 3 + 4 + 5)
Signature:
Building Commissionerllnspector of Buildings
Current Mailing Address: [=~~..--I _.5~
Telephone
(a) Building Permit Fee
Building Permit Fee
This Section For Official Use Onl
Date
Issued
Date
Official Use Only
Joo
Versionl.7 Commercial Building Permit May 15, 2000
SECTION 4-CONSTRUCTION SERVICES FOR PROJECTS LESS THAN 35,000 I
CUBIC FEET OF ENCLOSED SPACE ~------------.------------------~
Interior Alterations D Existing Wall Signs D Demolition D Repairs p( Additions D Accessory Building D
! Exterior Alteration D Existing Ground Sign 0 New Signs D Roofing 0 Change of Use D Other D .;;/:
·::::;::::'k'1~~~if~~~~~,,;:c¥·~~~~eT-~'
M Mixed Use ~
S Special Use Specify: LD
COMPLETE THIS SECTION IF EXISTING BUILDING UNDERGOING RENOVATIONS, ADDITIONS AND/OR CHANGE IN USE
Existing Use Group: If"")· ..~...__...._.,! Proposed Use Group: L...__._.._..~:::::;::.:;::=======:::::~~==:.II'-t:::-(JCf.l r-'5
Existing Hazard Index 780 CMR 34): 1"'-\-·="',...."I""...,,""....L·......._·········_-1 Proposed Hazard Index 780 CMR 34): L~~"·!
SECTION 6 BUILDING HEIGHT AND AREA I
OFFICE USE ONLY BUILDING AREA EXISTING PROPOSED NEW CONSTRUCTION
Floor Area per Floor (sf) )00 CRrw-ief:>
1st L .~=~=~~~~.=-~.~~======~~]
......._.....___........,\
Total Proposed NTW Co-".!struction (§fL__' j
;~"""_~""'"__,___.,~~~,_~~_--' __,,-..J
Total Height (ft) i 1
~-.~.~..-.. -~.~...-..---~
Total Height ft !
7. Wate( ~upply (M.G.L c. 40, § 54) 7.1 FI90(L~9ne-lnformation: 7.3 Sewage Disposal System:
Public lli1 Private D Zone L ... _.__.J Outside Flood ZoneD Municipal D On site disposal systemD
L"". J. :~...L-. ..."... "... ~. .·".".·._....w.. . "......~.__..~...w ••••_.p.............._
SECTION 5 -USE GROUPAND CONSr~UCTION TYPE I
A Assembly 0
B Business D
E Educational 0
F Factory 0
H High Hazard D
I Institutional D
M Mercantile D
R Residential D
S Storage D
U Utility D
USE GROUP (Check as applicable)
A-1 D A-2 D
A-4 D A-5 D
A-3 D
F-1 0 F-2 D
1-1 D 1-2 D 1-3 D
R-1
S-1
D
D
Specify: I
R-2
S-2
D
D
R-3 D
···-._..·w·...... ··· . ............... ......... . ....••
CONSTRUCTION TYPE
1A D
1B D
2A
2B I
0
D
2C 0
3A D
3B D
4 D
5A D
)8J:.5B
j
I "
Versionl.? Commercial Building Pennit May 15,2000
roposed Required by Zoning
This column to be filled in by
Building Department
'-8-.-N-O-RTH-A-M-P~T-O-N-Z-O-NIN-"-G---' AJ() e~/J t
Lot Size
Fronta e
Setbacks Front
• Building Height
Bldg. Square Footage
Open Space Footage
(Lot area minus bldg & paved
arl4n )
# of Parkin S aces
Fill:
(volume & Location)
Existing
A. Has a Special Permit/Variance/Finding ever been issued for/on the site?
NO 0 DONT KNOW @ YES 0
IF YES, date issued:
IF YES: Was the permit recorded at the Registry of Deeds?
NO 0 D~~:~~?~~~~Q
IF YES: enter Book.
YES
and/or Docu'ment #
, ~~•• ~,_~"",-,-,-,,,__-,_,,,,, """" '''-,,"~~".,.w.wmN
B. Does the site contain a brook, body of water or wetlands? NO % DONT KNOW 0 YES 0
IF YES, has a permit been or need to be obtained from the Conservation Commission?
Needs to be obtained Obtained , ~ate Issued:
o o
C. Do any signs exist on the property? YES .,.@ 0NO
IF YES, describe size, type and location:
NO~
E. Will the construction activity disturb (clearing, grading, excavation, or filling) over 1 acre or is it part of a common plan
that will disturb over 1 acre? YES 0 NO (lJ .
IF YES, then a Northampton Storm Water Management Permit from the DPW is required.
Version 1.7 Commercial Building Permit May 15, 2000
SECTION 9-PROFESSIONAL DESIGN AND CONSTRUCTION SERVICES -FOR BUILDINGS AND STRUCTURES SUBJECT TO
CONSTRUCTION CONTROL PURSUANT TO 780 CMR 116 (CONTAINING MORE THAN 35,000 C.F. OF ENCLOSED SPACE)
['!I~~if/'(l!
Telephone
Telephone
Signature
9.3 General Contractor
NotJ\PpliC:Cl~le 0
l7tfJl"..
Registration
[~T:"'" '(2
[~.~~~'..
Area of Responsibility
········~'J~3m.·::~'t......
IZ····
,~S'f-opol,-:::r-.:.~rp!-!!~~~-+':---=£-!!!~~_--sC~)S3~'I~il~t.,
Telephone
Not Applicable 0
/
Version1.7 Commercial Building Permit May 15, 2000
SECTION 10-STRUCTURAL PEER REVIEW (780 CMR 110.11)
I=n.nin.",,,,,'inn Structural Peer Review uired
-TO BE COMPLETED WHEN
OWNERS AGENT OR CONTRACTOR APPLIES FOR BUILDING PERMIT
No
lto'~~~~~~~=d~~~~========~==========================
ing permit applicatiop,:_ ""'."".',:"-:'-'r'-'"
ft
b~~bI.&df:t;~:l!,;g~~~~Mbl=*::!.::::!~~~~~=:±~~~======d__-, a~/Authorized
Agent hereby declare that the statements and information on the foregoing application are true and accurate, to the best of my knowledge
and belief.
Expiration ate
Telephone
SECTION 13 -WORKERS' COMPENSATION INSLIRANCE AFFIDAVIT (M.G.L. c. 152, § 25C(6))
Workers Compensation Insurance affidavit must be completed and submitted with this application. Failure to provide this affidavit will result in the denial of the issuance of
Affidavit Attached Yes
City of Northampton
Massachusetts
DEPARTMENT OF BUILDING INSPECTIONS
212 Main Street _ Municipal Building
Northampton, MA 01060
INSPECTOR
Louis Hasbrouck Fax: 413-587-1272 Chuck lVIiller
Building Commissioner Phone: 413-587-1240 Assistant Commissioner
SECONDARY CONSTRUCTION CONTROL DOCUMENT
(For professional Engineers/Architects responsible for a portion of a controlled project)
Project Title: McCarthy Properties Facade Repair and Reconstruction Date:__-=2..:..4.:..A::£p.:.:ri::,.1::.20.:..;1;;,;;2~____
Project Location: 263-271 Pleasant Street, Northampton Map: 32C Parcel:~Zone:~
Scope of Project: Remove failing brick wall, repair foundation beneath, reconstruct replacement brick wall.
In accordance with the Eighth edition Massachusetts State Building Code, 780 CMR Section 107.6:
I, _____--::.P..;;.et;;,;;e;;;..r;:.;Fr;;.::o;..:.;th;;,;;in:;;;jg;o;;h;;,;;am=-_____________ Mass. Registration # _...;.7...:,.80...;,1____
being a registered professional ~I!I&l:IliArchitect hereby CERTIFY that I have prepared or directly supervised
the preparation of all design plans, computations and speCifications concerning:
( ] fire i2feiestieFl' OQ Architectural [J Str:uctln:al i" I MeehaflieaJ (] Eleetrieal
[ ] Othel (SpeClfyt=___________________________
for the above named project and that to the best of my knowledge, such plans, computations and specifications
meet the applicable provisions of the Massachusetts State Building Code, all acceptable engineering practices
and all applicable Laws for the proposed·project.
Furthermore, I understand and AGREE that I shall perform the necessary professional services to determine that
the above mentioned portions of the work proceed in accordance with the documents approved for the building
permit.
Upon completion of the work, I shall submit to the building official a final report as to the satisfactory
Completion of the above mentioned work.
(seal)
The Office of
PETER FROTHINGHAM
Registered Architect
181 Main Street, Suite One
Northampton MA 01060
USA
4135855910
24 April 2012
Mr. Louis Hasbrouck, Building Commissioner
Puchalski Municipal Building
212 Main Street
Northampton MA 01060
Re: 1101 -McCarthy Properties Fa<;ade Repairs and Reconstruction
Subject: Central Business Architecture Commission Review
Mr. Hasbrouck,
This letter accompanies an application for a building permit for the repair and reconstruction of a
failing portion of the east wall of an existing building, effectively the tan brick portion which
includes the addresses 263-271 Pleasant Street, Northampton MA. The scope of work is to
remove the delanIinating exterior brick wall at the upper stories as well as the first floor storefront
in order to repair and augment the foundation wall beneath. We propose to reconstruct this wall
with new storefront and a brick veneer wall to be substantially similar to the existing.
Central Business Architecture Ordinance Section 156-5 lists numerous instances when a project
can be exempt from review. In particular, Section 156-5.C.18 explains: "Restoration offeatures
of the same general design and appearance as existed historically on a structure when the
Building Commissioner or Committee finds that there is adequate evidence to believe that
the restoration is historically accurate and the restoration will not damage other historic
features nor alter the historic character of the building."
We respectfully request such an exemption. In support of our request that this above named
project be exempt from CBAC review, attached are images of existing conditions and proposed
reconstruction for your review.
Sincerely,
q7~frtAt..J~
Peter Frothingham
Page 1 of2
EXISTING:
PROPOSED:
Page2of2
PrlntForrnThe Commonwealth ofMassachusetts
Department ofIndustJ'ial Accidents
Office ofInvestigations
1 Congress Street, Suite 100
Boston, MA 02114-2017
www,mass,govldia
Workers' Compensation Insurance Affidavit: Builders/ContractorslElectricians/Plumbers
Applicant Information Please Print Legibly
Name (Business/OrganizationlIndividual): -Ji2~JNC> t! OIJSTJt, vCT;()/J., :z;c)(
Address: ~~G> Tf ~ D-S/e ~.
City/State/Zip: (!'If. OlfJO)-Phone #:
Are ~an employer? Check th appropriate box:
I. ErI am a employer with A 0
employees (full and/or part-time). *
2.0 I am a sole proprietor or partner
ship and have no employees
working for me in any capacity.
[No workers' compo insurance
required.]
3.0 I am a homeowner doing all work
myself. [No workers' compo
insurance required.] t
4. 0 I am a ?eneral contractor and I
~ave hIred the sub-contractors
hsted on the attached sheet.
These sub-contractors have
employees and have workers'
compo insurance.t
5. 0 We are a corporation and its
officers have exercised their
right of exemption per MGL
c. 152, §1(4), and we have no
employees. [No workers'
compo insurance required.]
J-S-fJ --of7J?
Type of project (required):
6. 0 New construction
7. [3-Remodeling
8. 0 Demolition
9. 0 Building addition
10.0 Electrical repairs or additions
11.0 Plumbing repairs or additions
12.0 Roofrepairs
13.[3'Dther 4T4t1.lDI't. RW8J ~
"'Any applicant that checks box #1 must also fill out the section below showing their workers' compensation policy information.
t Homeowners who submit this affidavit indicating they are doing all work and then hire outside contractors must submit a new affidavit indicating such.
!Contractors that check this box must attached an additional sheet showing the name of the sub-contractors and state whether or not those entities have
employees. Ifthe sub-contraetors have employees, they must provide their workers' compo poliey number.
I am an employer that is providing workers' compensation insurance for my employees. Below is the policy and job site
information.
Insurance Company Name:_...nC-l---=..-.-:..I-=---=-:-.-:..M---,-.-:.._'_________________...,----:-______
Policy # or Self-ins. Lic.#: W,y -C S'006;{J.3ok'c>'~
Job Site Address: d 63 -j 6 7 'P /ru A-Ari n.
Attach a copy of the workers' compensation policy declaration page (showing the policy number and ex ration date).
Failure to secure coverage as required under Section 25A ofMGL C. 152 can lead to the imposition of criminal penalties of a
fine up to $1,500.00 and/or one-year imprisonment, as well as civil penalties in the form of a STOP WORK ORDER and a fine
ofup to $250.00 a day against the violator. Be advised that a copy of this statement may be forwarded to the Office of
Investigations of the DIA for insurance coverage verification.
th...a...to.;t.;,;h,;;,e...i.;.i;nfi~o...r.;,;m;,;a""'ition provided above is true and correct.
Expiration Date:-I-'+~l--==--L---==--_
City/State/Zip:'~aoLLf-.LLL.~:W'--.f-J~f'J.
~",",-=-.......""""."""/!""""=""""~""""""""",,,,,,..&~~~...
Official use only. Do not write in this area, to be completed by city or town official
City or Town: ________________ PermitlLicense
Issuing Authority (circle one):
1. Board of Health 2, Building Department 3. CitylTown Clerk 4. Electrical Inspector 5, Plumbing Inspector
6.0ther ________________
Contact Phone
Phone#: 713 -£o/f-I/O ">
. NOTICE NOTICE
TO
TO
EMPLOYEES EMPLOYEES
.The ComDlonwealth of Massachusetts
DEPARTMENT OFINDUSTRIAL .ACCIDENTS .
. 600 Washi:qgton Street, Boston, Massachus~tts 02111
617-727-4900 .
As l'f'nuir:ed hyM~<;<\achusetts Gen~ra1 Law, Cha,pter 152, Sections 21, 22 &30, this"wilI give you
nC~1ce that I(we) have provided fot payment to our injured employees under the above mentioned.
. chapter by insuring with:
ASSOCIATED INDUSTRIES OF MASSACHUSETTS MUTUAL INSURANCE COMFANY .
NAME OF INSURANCE COMPANY
54 THIRD AVENUE1 P,O. BOX 4070, BURLINGTON, MA 01803-0970
ADllIP..ESS OlF ]NSl.JRANCE COMPAN'"J{
WMZ 8006223012012 .~..-
POLICY NUMBER
04/01/2012 -04/01/2013
EFFECTIVE DATES
Phillips Insurance Agency Inc.
. NAME OF INSURANCE AGENT
97 Center Street
Chicopee, MA 01013
ADDRESS
(413) 594-5984
PHONE
Teagno Construction, Inc. 228 Triangle Street Amherst, MA 01002
EMPLOYER ADDRESS
02109/2012 .
EMPLOYER'S WORKERS COMPENSATION OFFICER (IF ANY) DATE
MEDICAL TREATMENT
The above named insurer is required in cases of personal injuries arising out of and in the course of employment to furnish
adequate and reasonable hospital and medical services in accordance with the provisions of the Workers Compensation Act .
. A copy of the First Report of Injury must be given to the injured employee. The employee may select his or her own physician.
The reasonable cost of the services provided by the treating physician will be paid by the insurer, ifthe treatment is necessary
.. and reasonably connected to the work related injury. Incases requiring hospitaI attention, employees are hereby notified that
the insurer has arranged for such attention at the .
NEAREST AND BEST MEDICAL FACILITY
" I
NAME OF HOSPITAL ADDRESS
TO BE POSTED BY EMPLOYER
-Harold R. Cutler, P.E.
Consulting Fire Protection Engineer
165 Landham Road
Sudbury, MA 01776 -3156
Voice & fax 978-443-7088
Email hcutlercfpe@Verizon.net
May 2,2012
PIN 2132
Office of the Building Commissioner
Puchalski Municipal Building
Northampton, MA 01060
Attention: Louis Hasbrouck
Building Commissioner
Dear Mr. Hasbrouck:
Subject: Request for Acceptance of a Compliance Alternative
. Height Limitation
263-271 Pleasant Street, Northampton
This letter is submitted on behalf of the McCarthy Properties, Inc., the owner of, the
building at 263-271 Pleasant Street, Northampton and Peter Frothingham, the architect
for the proposed renovation project at the building. It is submitted to request your
department's consideration and acceptance of a compliance alternatives in accordance
with Section 101.5.0 of the Existing Building Code of Massachusetts (EBCM) with
respect to the story height limitation for an unsprinklered building of Type VB
construction and Use Groups B, M, A-3 and R-2 occupancy.
In addition to references to the EBCM, this letter will also refer to the requirements of
the Eighth Edition of the Massachusetts State Building Code (MSBC8) for new
construction.
Existing Conditions
Key characteristics of the existing building for purposes of this discussion may be
summarized as follows:
1. The existing construction type is Type IIIB based on non-combustible exterior
masonry walls having two-hour fire ratings and interior unrated and combustible
or non-combustible structural elements and floor and roof assemblies.
2. The building has three stories and a basement.
Louis Hasbrouck, NHBD Page 2 May 2,2012
3. The building's dimensional height is 38' high above average grade measured
from average grade to the highest point of the existing flat roof.
4. The building area is approximately 6,420 sf based on the footprint of the building.
5. The aggregate area of all stories is 18,140 sf.
6. The primary existing occupancy classifications are Use Group B (offices), M
(retail stores), A-2nc (bar with an occupant load of less than 100 persons) and R
2 (apartments).
7. The existing occupancies are arranged as non-separated mixed uses.
8. The building is provided with a fire detection and alarm system that includes the
following features: (a) system connected smoke detectors and manual pull
stations in the three interior exit stairs at the front of the building that serve the
Second and Third Floor apartments, (b) system connected smoke and heat
detectors in the basement of the building, (c) system connected heat detectors
on the exterior rear decks that serve as rear exits for the Second and Third Floor
apartments and (d) a variety of photocell smoke detectors, heat detectors, and
audible signaling devices in the various first floor spaces.
9. The 'fire alarm system includes a connection to the Northampton Fire Department
for transmission of alarms to that department.
10. Single or multiple station smoke detectors are provided vwithin individual
apartments.
11. Automatic sprinkler protection is not provided.
12.The means of egress is based on exit access corridors and aisles leading to
enclosed exit stairs or doors to the exterior at grade at the front of the building
and rear exterior porches and exterior stairs or doors to the exterior at grade at
the rear of the building.
Proposed Renovations
It is proposed to remove and replace the existing brick masonry fayade of a portion of
the front wall of the building with a new, lighter and better-insulated exterior wall. The
proposed work is required to reduc_e the loading on a compromised foundation due to
significant differential settlement orihe foundation. The project will involve removing the
top 12-20" inches of foundation, repairing as needed the remaining brick to ensure good
bearing surfaces, and replacing the upper portion of the foundation with a reinforced
concrete bond-beam.
On top of this new foundation cap, there will be a fayade similar in appearance to the
existing fayade but lighter in weight using an anchored brick veneer backed by wood
studs supported by new steel beam and columns at first floor level. The wall assembly
will include a 1" cavity, an inch of XPS insulation (taped, as air and moisture barrier).
three-quarter inch plywood sheathing and fiberglass batt insulation between studs.
The 51 feet of new wall will be only 14% of the 370 feet of the total perimeter of the
building. The remainder of the perimeter will continue to be the existing substantial brick
masonry walls.
Louis Hasbrouck, NHBD Page 3 May 2,2012
As a result of the reconstruction of the front wall with combustible materials as structural
elements without a fire rating, the proposed project results in a change of construction
type for the building from Type IIIB to Type VB construction.
Analysis of Height and Area Limitations
The attached Table No.1 documents calculation of the allowable heights and areas of a
building with the characteristics of the building at 263-271 Pleasant Street upon
completion of the current project including its Type VB construction. These calculations
indicate the building will satisfy the Code's area limitations for all of its occupancies after
credit is taken for the 100% of the perimeter that faces public streets and unoccupied
open spaces.
The calculations in Table No.1 indicate the building, based on its post-project Type VB
construction, will satisfy the dimensional height but will not satisfy the story height
limitations for any of its occupancies as a nonseparated mixed-use building. The
following is a summary of those story height restrictions:
• The story height limitation for Use Group A-20ccupancy is one story. The Use
Group A-2 space is located on the First Floor of the building
• The story height limitation for Use Group B occupancy is two stories. The Use
Group B spaces are located on the First Floor of the building
• The story height limitation for Use Group M occupancy is one story. The Use
Group M spaces are located on the First Floor of the building
• The story height limitation for Use Group R-2 occupancy is two stories. The Use
Group R-2 spaces are located on the Second and Third Floors of the building
If the building were arranged with separated mixed uses, the Use Group A-2, Band M
occupancies would be located as permitted on the First Floor of the Building. Only the
spaces of R-2 occupancy would be above the allowable story heights for that
occupancy. The required occupancy separations would have to have be two-hour fire
rated Second Floor assemblies. The existing floor assemblies are unrated.
Compliance Alternative Request
Your acceptance of a compliance alternative to the story height limitations for all four
occupancies of the building is requested.
We believe the requested story height compliance alternative is justified by the following
factors concerning this building and the proposed project:
1. The project is being undertaken to correct an unsafe structural condition.
2. The project will not result in a change of occupancy of the building or expansion
of the existing height or area of the building.
3. Eighty-six percent of the perimeter wall of the building will continue to qualify for
the current Type IIiB construction.
Louis Hasbrouck, NHBD Page 4 May 2,2012
4. The building is subdivided by an unpierced masonry wall having a minimum fire
rating in excess of two hours into a southern section having floor areas of 3,895
sf on each floor and a northern section having 1100r areas of 2,500 sf or less on
each floor.
5. The building is provided with a fire detection and alarm system that includes
system connected smoke detectors in the three interior stairways serving the
residential floors and heat detectors on the exterior rear decks and stairs.
6. The maximum travel distances on an individual 1100r to a front or rear exit stair or
to a door to the exterior are not more than 36 feet. That distance is compared to
a maximum travel distance of 200 feet permitted for the four occupancies in an
unsprinklered building.
7. The exit stairs are only three stories high.
8. The upper levels of the building are within reach of fire department ground
ladders and aerial ladders.
Conclusions
The reconstruction of 14% of the exterior wall with wood-framed construction requires
derating of the construction type of the building from Type IIiB to Type VB construction.
However, that change has little impact on the conditions in the building affecting the
safety of building occupants including the fire detection and alarm system that will
provide an early warning of a fire condition and the short travel distances to interior and
exterior exits. The overall small size of the building will facilitate fire department
operations inside and outside the building.
Our Request
On the basis of the above analysis of the hazards and protection characteristics of the
building at 263-271 Pleasant Street, we request your acceptance of the above listed
features and characteristics as a compliance alternative to the code requirements
related to the story height limitations of the code for new construction.
Thank you for your cooperation.
Very truly yours
Harold R. Cutler
cc: Peter Frothingham
Louis Hasbrouck, NHBD Page 5 May 2,2012
TABLE. NO 1
ALLOWABLE HEIGHT AND AREA CALCULATIONS
BUILDINGS OF USE GROUPA"?1.~!M AND R-?()<::C;~PANCY
BASIC BUILDING A",D SITE CHARACTERISTICS
OCCUPANCY A-2
CONSTRUCTION TYPE V-B
HEIGHT (FT.) . 38
HEIGHT (ST.). 3
6,420
TOTAL BUIL,[)ING AREA(SF~)
LARGEST SINGLE FLOOR AREA (SF.)
18,140
SPRINKLER~(rOR N)., N
% FRONTAGE : 100
, ,,-.,-, -" ---.".-.
30WIDTH OF PUBLIC WAY OR OPEN SPACE (FT.).
,
B
V-B
38
3
6,420
18,140
N
100
30
M
V-B
38
3
6,420
18,140
N
100
30
R-2,
V-B
38
3
6,420
18,140
N
100
30
(SEE RESTRICTIONS IN SECTION 506.2.1)
(20 =< W <= 30)
ALLOWABLE HEIGHT DETERMINATION
TABLE 503 LIMITATION (FT'/ST.)
INCREASE FOR SPRINKLERS (504.2)
ALLOWABLE HEIGHT (FT.!ST:)
,
40/1
0
40/1
40/2 40/1 40/2
010 0/0 0/0
40/240/2 40/1
,
,ALLOWABLE SINGLE FLOOR AREA DETERMINATION
TABLE 503 L1MITATI()N(SF.)
BASIC ALLOWANCE FACTOR(506.1)
INCREASE FOR FRONTAGE (506.2)
"=(% FRONTAGE -25%)*(WIDTH/30)"
INCREASE FOR SPRINKLERS (506~3)
"= 2.00 FOR MULTISTORY BUILDINGS"
"= 3.00 FOR SINGLE STORY BUILDINGS"
TOTAL ALLOWABLE AREA MULTIPLIER
,,'
;'
6,000 9,000
1.00 1.00
0.75 0.75 ,
9,000 7,000'
1.00 1.00'
0.75 0.75
0.00 II 0.00 II 0.00'
1.75
TOTAL ALLOWABLE SING~g FLOOR AREA (SF.) 110,5001115,7501115.75011 12,250
ALLOWABLE AGGREGATE BUILDING AREA DETERMINATION
ALLOWABLE BUILDING AREAFAcToR (SOj,3) 3 II 311 311 3
u: 1 *(ALLOWABLE FLOOR AREA FOR' ~T. BUILDINGS',,) ,
"= 2*(ALLOWABLE FLOOR AREA FOR 2 ST. BUILDINGS';)
"= 3*(ALLOWABLE FLOOR AREA FOR MORE THAN2ST.;'):
ALLOWABLE BUILDING AREA (TOTAL FOR ALL FLOORSt' , "'-13-'-,5-0-01I......4_7.!.."2 50..;....L,,,l1______ 47.:......2..::..50~U 36,750