Loading...
fwdconfirmedhersratingdraftreports250glendale Home Energy Rating Summary Report - Draft.pdfEStarV3Summary ENERGY STAR v3.0 Home Verification Summary Property N/A 250 Glendale Road Northhampton, MA 01062 Weather:Northampton, MA Lot 1 Glendale Road 250 Glendale Road 14.6.4.blg Organization Infrared New England 508-728-1099 Norbert Reichhold Builder Chris Gonzalez REM/Rate - Residential Energy Analysis and Rating Software v14.6.4 This information does not constitute any warranty of energy cost or savings. © 1985-2016 Noresco, Boulder, Colorado. HERS Confirmed 2017-06-29 Rating No:690 Rater ID:5209289 Confirmed: - No Registry ID Building Information Rating Conditioned Area (sq ft) 3594 HERS Index 45 Conditioned Volume (cubic ft) 26706 HERS Index w/o PV 45 Insulated Shell Area (sq ft) 8369 HERS Index Target (SAF Adjusted) 64 Number of Bedrooms 4 HERS Index of Reference Design Home 68 Housing Type Single-family detached Size Adjustment Factor 0.94 Foundation Type Unconditioned basement This home DOES NOT MEET the EPA's requirements for an ENERGY STAR Home. HERS Index w/o PV <= HERS Index of Reference Design Home AND HERS Index <= HERS Index Target to comply. Building Shell Ceiling w/Attic R38,CE,6-24,F U=0.026 Window Type U:0.25, SHGC:0.25 Sealed Attic None Window U-Value: 0.250, SHGC: 0.250 Vaulted Ceiling R38,CE,6-24,C U=0.025 Window/Wall Ratio 0.15 Above Grade Walls R21,FG1,6-16 U=0.058 Infiltration Type Blower door test Found. Walls(Cond) None Infiltration Htg: 730 Clg: 730 CFM50 Found. Walls(Uncond) R0,10.6E,10" R=10.6 Duct Leakage to Outside 13.00 CFM @ 25 Pascals Floors R38,FG2,12-24 U=0.034 Total Duct Leakage 107.00 CFM @ 25 Pascals Slab Floors None Mechanical Systems Heating Fuel-fired air distribution, 116.0 kBtuh, 96.7 AFUE. Cooling Air conditioner, 48.0 kBtuh, 13.0 SEER. Water Heating Instant water heater, Prop, 0.99 EF. Programmable Thermostat Heat=Yes; Cool=Yes Ventilation System Exhaust Only: 73 cfm, 15.0 watts. Lights and Appliances Percent Interior Lighting 100.00 Clothes Dryer Fuel Electric Percent Exterior Lighting 100.00 Clothes Dryer EF 3.01 Refrigerator (kWh/yr) 717.00 Clothes Washer LER 96.00 Dishwasher kWh/yr 260 Clothes Washer Capacity 3.81 Ceiling Fan (cfm/Watt): 0.00 Range/Oven Fuel Electric Note: Where feature level varies in home, the dominant value is shown. Air Leakage Report.pdfAirLeakage Air Leakage Property N/A 250 Glendale Road Northhampton, MA 01062 Weather:Northampton, MA Lot 1 Glendale Road 250 Glendale Road 14.6.4.blg Organization Infrared New England 508-728-1099 Norbert Reichhold Builder Chris Gonzalez Whole House Infiltration ASHRAE 62.2 - Ventilation Requirements The ASHRAE 62.2 flow rates shown above are the CONTINUOUS mechanical fresh air ventilation which will meet the 'whole-building' requirement under that version of the standard. Both values incorporate any appropriate 'infiltration credit'. Intermittent mechanical ventilation may be used if the flow rate is adjusted accordingly. For example, the runtime can be reduced to 12 hours per day using a doubled flow rate, as long as the system provides ventilation at least once every 3 hours. For more detail, refer to the appropriate standard. REM/Rate - Residential Energy Analysis and Rating Software v14.6.4 This information does not constitute any warranty of energy cost or savings. © 1985-2016 Noresco, Boulder, Colorado. HERS Confirmed 2017-06-29 Rating No:690 Rater ID:5209289 Duct Leakage Ventilation Blower Door Test Heating Cooling Natural ACH 0.10 0.07 ACH @ 50 Pascals 1.64 1.64 CFM @ 25 Pascals 465 465 CFM @ 50 Pascals 730 730 Eff. Leakage Area (sq.in) 40.1 40.1 Specific Leakage Area 0.00008 0.00008 ELA/100 sf shell (sq.in) 0.48 0.48 Leakage to Outside Units 1st & 2nd Floor CFM @ 25 Pascals 13 CFM25 / CFMfan 0.0052 CFM25 / CFA 0.0036 CFM per Std 152 N/A CFM per Std 152 / CFA N/A CFM @ 50 Pascals 20 Eff. Leakage Area (sq.in) 1.12 Thermal Efficiency N/A Total Duct Leakage Units CFM25/CFA Total Duct Leakage 0.0298 Mechanical Exhaust Only ASHRAE Sensible Recovery Eff. (%) 0.0 62.2-2010 Total Recovery Eff. (%) 0.0 Rate (cfm) 73 73 Hours/Day 24.0 24.0 Fan Watts 15.0 Cooling Ventilation Natural Ventilation BLOWER DOOR TEST-[Stretch Code-2009].pdfCustomer Information BLOWER DOOR TEST – Stretch Code 2009 Customer Information Test Conditions Name: C.I.L Reality Date: 6/27/17 Address: 157 Charter Oak Avenue Time: 12:15 pm City/State/Zip: Hartford, CT 06106 Temperature: 70 F Phone: Chris Gonzalez (860)-490-0934 / (860)-509-6757 Wind Speed: 8 mph Email: cgonzalez@cil.org Relative Humidity: 56% Test Location Base Pressure: 0.1 pa Range: 0.1 pa / 0.3 pa Street: 250 Glendale Road Test Pressure: - 50 pa City/State/Zip: Northhampton, MA 01062 Volume : 26,706 cu/ft Comments: PASSED @ 1.64 air changes per hour Fan Model: Retrotec 5000 Serial Number: 100402 Fan Flow Ring: B4-ring Fan Flow Pressure: 730 CFM Test Criteria: 4 air changes per hour Test Results: 1.64 ACH Test Performed by: Gerald T. Brady Certified HERS Rater # 3118495 Address: 18 Fiske Street, Shrewsbury, MA. 01545 Phone: 508-728-1099 Signature: www.InfraredNewEngland.com “See what’s hot and what’s not.” DUCT TEST-[Stretch Code].pdfDUCT LEAKAGE TEST – IECC 403 DUCT LEAKAGE TEST – Stretch Code CUSTOMER INFORMATION Name: C.I.L Reality Address: 157 Charter Oak Avenue City/State/Zip Code: Hartford, CT 06106 Phone: Chris Gonzalez (860)-490-0934 / (860)-509-6757 Email: cgonzalez@cil.org TEST LOCATION Street: 250 Glendale Road City/State/Zip Code: Northhampton, MA 01062 TEST CONDITIONS Date: 6/27/17 Time: 12:00 pm Indoor Temp: 68 F Outdoor Temp: 70 F Supply Location: Attic Return Location: Attic Pressurization: 25 pa Depressurization: Fan Model: Retrotec DU200 Serial Number: FT9010335 TOTAL LEAKAGE RESULTS Zone / Sq/ft Duct-A Pressure Fan-B Pressure Flow Ring Flow Pressure / Leakage % 1st - 2nd Floor / 3,594 sf 25.0 pa 11.7 pa Open 107 cfm / 3.0% LEAKAGE TO OUTDOORS RESULTS Zone / Sq/ft Duct-A Pressure Fan-B Pressure Flow Ring Flow Pressure / Leakage % 1st - 2nd Floor / 3,594 sf 25.0 pa 69.1 pa Low 13 cfm / 0.4% HVAC Contractor: Suburban Heating and Cooling Comments: Testing Performed By: Gerald T. Brady Certified HERS Rater # 3118495 Address: 18 Fiske Street, Shrewsbury, MA. 01545 Phone: 508-728-1099 Signature: www.InfraredNewEngland.com “See what’s hot and what’s not.” TBC.pdf ENERGY STAR Qualified Homes Thermal Bypass Inspection Checklist Posted 06/02/08 ENERGY STAR Qualified Homes Thermal Bypass Inspection Checklist Home Address: City: State: . Thermal Bypass Inspection Guidelines Corrections Needed Builder Verified Rater Verified N/A Requirements: Insulation shall be installed in full contact with sealed interior and exterior air barrier except for alternate to interior air barrier under item no. 2 (W lls Adjoining Exterior Walls or Unconditioned Spaces) a All Climate Zones: 1.1 Overall Alignment Throughout Home 1.2 Garage Band Joist Air Barrier (at bays adjoining conditioned space) 1.3 Attic Eave Baffles Where Vents/Leakage Exist Only at Climate Zones 4 and Higher: 1.4 Slab-edge Insulation (A maximum of 25% of the slab edge may be uninsulated in Climate Zones 4 and 5.) Best Practices Encouraged, Not Req’d.: 1.5 Air Barrier At All Band Joists (Climate Zones 4 and higher) 1. Overall Air Barrier and Thermal Barrier Alignment 1.6 Minimize Thermal Bridging (e.g., OVE framing, SIPs, ICFs) Requirements: • Fully insulated wall aligned with air barrier at both interior and exterior, OR • Alternate for Climate Zones 1 thru 3, sealed exterior air barrier aligned with RESNET Grade 1 insulation fully supported • Continuous top and bottom plates or sealed blocking 2.1 Wall Behind Shower/Tub 2.2 Wall Behind Fireplace 2.3 Insulated Attic Slopes/Walls 2.4 Attic Knee Walls 2.5 Skylight Shaft Walls 2.6 Wall Adjoining Porch Roof 2.7 Staircase Walls 2. Walls Adjoining Exterior Walls or Unconditioned Spaces 2.8 Double Walls Requirements: • Air barrier is installed at any exposed fibrous insulation edges • Insulation is installed to maintain permanent contact with sub-floor above including necessary supports (e.g., staves for blankets, netting for blown-in) • Blanket insulation is verified to have no gaps, voids or compression. • Blown-in insulation is verified to have proper density with firm packing 3.1 Insulated Floor Above Garage 3. Floors between Conditioned and Exterior Spaces 3.2 Cantilevered Floor Requirements: Openings to unconditioned space are fully sealed with solid blocking or flashing and any remaining gaps are sealed with caulk or foam (provide fire-rated collars and caulking where required) 4.1 Duct Shaft 4. Shafts 4.2 Piping Shaft/Penetrations 4.3 Flue Shaft Requirements: • All attic penetrations and dropped ceilings include a full interior air barrier aligned with insulation with any gaps fully sealed with caulk, foam or tape • Movable insulation fits snugly in opening and air barrier is fully gasketed 5.1 Attic Access Panel (fully gasketed and insulated) 5.2 Attic Drop-down Stair (fully gasketed and insulated) 5.3 Dropped Ceiling/Soffit (full air barrier aligned with insulation) 5.4 Recessed Lighting Fixtures (ICAT labeled and sealed to drywall) 5. Attic/ Ceiling Interface 5.5 Whole-house Fan (insulated cover gasketed to the opening) Requirements: Gap between drywall shaft wall (i.e., common wall) and the structural framing between units is fully sealed at all exterior boundary conditions 6. Common Walls Between Dwelling Units 6.1 Common Wall Between Dwelling Units Home Energy Rating Provider: _______________________ Rater Inspection Date: _______________ Builder Inspection Date: _______________ Home Energy Rater Company Name: ___________________________ Builder Company Name: _______________________________________ Home Energy Rater Signature: ________________________________ Builder Employee Signature:_____________________________________