28 -014 TUR PERMIT FEB 4 2019Proposed Renovations to 249 SYLVESTER ROAD Florence, Massachusetts 42'-4" 15'-2"12'-0"15'-2"28'-4"10'-8"UP UPfilter HWH furnace elec panelSANITARY LINE EXISTING BASEMENT PLAN Scale: 1/4" = 1'-0"EX1 0 5 10 FT January 14, 2019 LINE OF EXISTING SANITARY LINE, ABOVE Proposed Renovations to 249 SYLVESTER ROAD Florence, Massachusetts February 4, 2019utility sinkW D EXISTING LAUNDRY ROOM PLAN Scale: 1/2" = 1'-0"EX2 0 1 2 3 4 5 FT Proposed Renovations to 249 SYLVESTER ROAD Florence, Massachusetts February 11, 2019 W/D 36" sink base24" drawer base18" trash basefuture storage by ownernew barn door REMOVE EXISTING DOOR RELOCATE EXISTING WASHER AND DRYER. INSTALL AS STACKED UNITS filler filler PROPOSED LAUNDRY ROOM PLAN Scale: 1/2" = 1'-0"SD3 0 1 2 3 4 5 FT Proposed Renovations to 249 SYLVESTER ROAD Florence, Massachusetts February 4, 2019 UP UPfilter HWH furnace elec panel42'-4" 15'-2"12'-0"15'-2"10'-8"RELOCATE SANITARY LINE INTO NEW WALL STORAGE GYM PLAYROOM MECHANICAL ROOM ALIGN 30X8030X80 30X80±10'-4 1/2"3 1/2"±12'-11"10'-0" ±13'-1 1/4" COORDINATE W/ OWNER IN FIELD 3 1/2"±8'-5 3/4"28'-4"pair 30X80 TV REMOVE EXISTING INSULATION AT BASEMENT PERIMETER. INSTALL NEW 1/2" GWB. INSULATE FURRED WALL W/ CLOSED CELL FOAM INSULATION. TYPICAL. NEW 2X4 @ 16" OC. WOOD WALL W/ 1/2" GWB EA. SIDE. 1X4 PAINTED WOOD BASE. 5/4"X4" PAINTED WOOD TRIM AT DOOR AND WINDOW FRAMES. TYPICAL. ALIGN ±10" GWB SOFFIT AT HVAC / DUCT, ABOVE 3 1/2" 1'-6" FUR OUT WALL TO INCOPORATE / HIDE EX. SANITARY LINE & OTHER EXPOSED UTILITIES.2'-0"GWB SOFFIT AT HVAC / DUCT, ABOVE 5'-6"EXISTING INSULATION TO REMAIN AT MECHANICAL ROOM SPACE2'-6"ALIGN OPEN UP KNEE WALL BELOW STAIRS TO EXPAND ACCESS TO STORAGE NICHE. DETERMINE WIDTH IN FIELD.STORAGE NICHE BASEMENT PLAN Scale: 1/4" = 1'-0"A1 0 5 10 FT GENERAL NOTES: HVAC and Plumbing - Furnish and install all new supply and return ductwork, pipe, fittings, grills, registers, dampers and diffusers to accommodate new “finished space” in Basement area. - All connections to existing HVAC System as needed. - Furnish and install new properly sized Zone Control Damper and Programmable Thermostat. - Existing Zone Control to remain. Connect new Zone Damper to available terminal on existing Zone Control. - Any/all boxing in, or soffiting of new (and existing) ductwork, to be done by others. (Note: All existing ductwork, to remain “as is”.) - Relocate existing sewer line in “Playroom”, to new lower location. - All sundry, material and labor. - All wiring to complete installation. - Start up and test procedures. ELECTRIC - Wire new basement to code to include: - Remove relocate existing circuits throughout basement - Wire for new lighting circuit and circuit for gym to be Arc Fault protected - 20 Recessed Lights/Flat Disc LED. - Smoke/carbon detectors to remain - Rework switching and add 2 Receptacle outlets in Mechanical area - Add catv behind new tv location INSULATION - 3” Demilec Heatlok HFO R21 Closed Cell at exterior basement walls in finished areas only Proposed Renovations to 249 SYLVESTER ROAD Florence, Massachusetts February 4, 2019 UP UPfilter HWH furnace elec panelCATV SMOKE CO SMOKE CO SMOKE CO SDS4S4SDTO EXISTING BASMENT LIGHTING SD CATV CATV TO EXISTING BASMENT LIGHTING S4TO EXISTING BASMENT LIGHTING R1 R1 R1 R1 R1 R1 R1 R1 R1 CATV SMOKE CO SD S4 RECESSED OR SURFACE MOUNT LED LIGHT FIXTURE OUTLET CABLE T.V. COMBINATION SMOKE/CO MONITOR DIMMER LIGHT SWITCH 4-WAY LIGHT SWITCH KEY: GWB SOFFIT AT HVAC / DUCT, ABOVE GWB SOFFIT AT HVAC / DUCT, ABOVE R1 R1 R1 R1 S1 SURFACE MOUNT LED LIGHT FIXTURE S1 REFLECTED CEILING PLAN Scale: 1/4" = 1'-0"A2 0 5 10 FT GENERAL NOTES: INSTALL NEW OUTLETS AT SPACING AS REQUIRED BY CODE. ADJUST LAYOUT OF NEW OUTLETS TO WORK WITH EXISTING POWER OUTLETS.