Loading...
25C-123 2018-09-29 Permit Set-notesSITE PLANSCALE: 1/8" = 1'-0"EXISTING SITE PLANSCALE: 1/8" = 1'-0"BRIDGE ST.BRIDGE ST.EXISTING HOUSE222 BRIDGE ST.EXISTING HOUSE222 BRIDGE ST.DISCONNECT AND REMOVE EXISTINGFIRST AND SECOND FLOOR PORCH ANDSTAIRS. REMOVE ENTIRE STRUCTUREINCLUDING EXISTING CONCRETEFOOTINGS17' +/-12'-3" +/-15'-6" +/-NEW SECOND FLOOR EGRESSCALLED NORTHScaleProject No.DateDrawn by033-2017222 Bridge Street, Northampton MA First and Second Floor Porch RemodelNo.DescriptionDate as notedS1.0Site Plan JGSJ. Sexton Construction & Design, LLC 49 Edward Drive Holyoke, MA 01040 413-210-1778Sept. 29, 2017 EXISTING PLANSCALE: 1/4" = 1'-0"NEW SECOND FLOOR PLANSCALE: 1/4" = 1'-0"NEW FIRST FLOOR PLANSCALE: 1/4" = 1'-0"EXISTING HOUSEEXISTING HOUSEEXISTING HOUSEEXISTING FRONT PORCHEXISTING FRONT PORCHEXISTING FRONT PORCHDISCONNECT AND REMOVE EXISTINGSECOND FLOOR EGRESS STAIR. REMOVEENTIRE STRUCTURE INCLUDINGEXISTING CONCRETE FOOTINGSEXISTING SECOND FLOORDOOR TO REMAINDISCONNECT AND REMOVE EXISTINGFIRST FLOOR PORCH AND STAIRS.REMOVE ENTIRE STRUCTURE INCLUDINGEXISTING CONCRETE FOOTINGS10-0"4-0"4'-0"19'10'-0"NEW FIRST FLOOR PORCHNEW NEW SECONDFLOOR EGRESS4'-0"7'-4"3'-4"7'-4' as notedA1.0Demolition & New Work Plan JGSScaleProject No.DateDrawn by033-2017222 Bridge Street, Northampton MA First and Second Floor Porch RemodelNo.DescriptionDateJ. Sexton Construction & Design, LLC 49 Edward Drive Holyoke, MA 01040 413-210-1778Sept. 29, 2017 FIRST FLOOR PORCH FRAMING PLANSCALE: 1/2" = 1'-0"4"X4" P.T. HANDRAIL POST.6"X6" P.T. POST. POST SHALL EXTEND UPTO SUPPORT SECOND FLOOR EGRESSBEAM CONSTRUCTED OF (2) 2"X10" P.T.SECURE TO 6"X6" POST WITH HIDDENDOUBLE 2"X10" SIMPSON HANGER2"X8" P.T. JOIST 16"O.C. SECURE TO LEDGER WITHSIMPSON 2"X8" JOIST HANGER. SECURE TOCARRYING BEAM WITH SIMPSON HURRICANE TIE.TYPICAL ALL LOCATIONSFULL SIZE BLOCKING ATCENTER SPAN2"X10" P.T. LEDGER BOARD.SECURE TO STRUCTURE WITHSIMPSON LEDGER LOCKS.1" FASCIA BOARDFULL SIZE RIM JOIST6"X6" P.T. POST. POST SHALL EXTEND UPTO SUPPORT SECOND FLOOR EGRESSSTAIR STRINGER AT 16"O.C. STRINGER TO BECONSTRUCTED FROM 2"X12" P.T. WOOD4"X4" P.T. POST TO SUPPORT HANDRAIL6"X6" P.T. POST. POST SHALL EXTEND UPTO SUPPORT SECOND FLOOR EGRESSINSTALL GALV. FLASHING AT ALLLOCATIONS WHERE LEDGER/DECKSECURES TO HOUSE. EXTEND DRIP EDGEOVER LEDGER.6"X6" P.T. POST. POST SHALL EXTEND UPTO SUPPORT SECOND FLOOR EGRESSBEAM CONSTRUCTED OF (2) 2"X10" P.T.SECURE TO 6"X6" POST WITH HIDDENDOUBLE 2"X10" SIMPSON HANGER1" FASCIA BOARD4"X4" P.T. HANDRAIL POST.BEAM CONSTRUCTED OF (2) 2"X10" P.T.SECURE TO 6"X6" POST WITH HIDDENDOUBLE 2"X10" SIMPSON HANGERSTAIR STRINGER MADE FROM 2X12. INSTALL 16"O.C.SECOND FLOOR PORCH FRAMING PLANSCALE: 1/2" = 1'-0"4"X4" P.T. POST TO SUPPORT HANDRAILFULL SIZE BLOCKING ATCENTER SPANBEAM CONSTRUCTED OF(2) 2"X10" P.T. SECURE TO6"X6" POST WITH (2) 12" DIA.GALV. HEX BOLTSBEAM CONSTRUCTED OF(2) 2"X10" P.T. SECURE TO6"X6" POST WITH (2) 12" DIA.GALV. HEX BOLTSBEAM CONSTRUCTED OF(2) 2"X10" P.T. SECURE TO6"X6" POST WITH (2) 12" DIA.GALV. HEX BOLTSFULL SIZE RIM JOIST2"X8" P.T. JOIST 16"O.C. SECURE TO LEDGER WITHSIMPSON 2"X8" JOIST HANGER. SECURE TOCARRYING BEAM WITH SIMPSON HURRICANE TIE.TYPICAL ALL LOCATIONS4"X4" P.T. HANDRAIL POST. as notedA1.1First & Second Floor Framing Plan JGSScaleProject No.DateDrawn by033-2017222 Bridge Street, Northampton MA First and Second Floor Porch RemodelNo.DescriptionDateJ. Sexton Construction & Design, LLC 49 Edward Drive Holyoke, MA 01040 413-210-1778Sept. 29, 2017 WEST ELEVATIONSCALE: 1/2" = 1'-0"SOUTH ELEVATOINSCALE: 1/2" = 1'-0"HANDRAIL NOT SHOWNFOR CLARITYNEW SECOND FLOORSTAIR EGRESSHANDRAIL NOT SHOWNFOR CLARITYNEW SECOND FLOORSTAIR EGRESS as notedA1.2Elevations JGSScaleProject No.DateDrawn by033-2017222 Bridge Street, Northampton MA First and Second Floor Porch RemodelNo.DescriptionDateJ. Sexton Construction & Design, LLC 49 Edward Drive Holyoke, MA 01040 413-210-1778Sept. 29, 2017 as notedA2.0TYPICAL CONNECTION DETAILS JGSScaleProject No.DateDrawn by033-2017222 Bridge Street, Northampton MA First and Second Floor Porch Remodel Sept. 29, 2017No.DescriptionDateJ. Sexton Construction & Design, LLC 49 Edward Drive Holyoke, MA 01040 413-210-1778