Loading...
10D-019 Structural Ridge CalcsCS Structure™ 2.14.50 [Build 4] kmBeamEngine 4.13.4.1 Materials Database 1530 JazabEd167MainStLeeds101515 -10-23-15 1:50pm 1 of 2 All product names are trademarks of their respective owners Copyright (C) 2015 by Simpson Strong-Tie Company Inc. ALL RIGHTS RESERVED.**Passing is defined as when the member, floor joist, beam or girder, shown on this drawing meets applicable design criteria for Loads, Loading Conditions, and Spans listed on this sheet. The design must be reviewed by a qualified designer or design professional as required for approval. This design assumes product installation according to the manufacturer`s specifications. Doug Hodgins rk Miles Inc. 21 West St. West Hatfield Ma. Member Data Description: CalcG1 Member Type: Girder Application: Roof Comments:Top Lateral Bracing: Continuous Slope: 0.00 / 12 Bottom Lateral Bracing: Continuous Standard Load: Moisture Condition: Dry Building Code: IBC/IRC Live Load: 0 PLF Deflection Criteria: L/360 live, L/240 total Dead Load: 0 PLF Deck Connection: Nailed Member Weight: 11.7 PLF Filename: C:\KMW\JOBS\ Other Loads Type (Description) Side Begin End Trib. Width Other Start End Dead Start End Category Replacement Uniform (PLF) Top 0' 0.00" 12' 9.50" 1 91 Live Replacement Uniform (PLF) Top 0' 0.00" 12' 9.50" 1 91 Live Replacement Uniform (PLF) Top 0' 0.00" 12' 9.50" 262 0 Snow Replacement Uniform (PLF) Top 0' 0.00" 12' 9.50" 262 0 Snow 1 2 12 9 8 12 9 8 Bearings and Reactions Input Min Gravity Gravity Location Type Material Length Required Reaction Uplift 1 0' 0.000" Wall SPF Plate (425psi) N/A 2.921" 4345# -- 2 12' 9.500" Girder SPF Plate (425psi) N/A N/A 4345# -- Maximum Load Case Reactions Used for applying point loads (or line loads) to carrying members Live Snow Dead 1 9# 3176# 1168# 2 9# 3176# 1168# Design spans 12' 1.375" Product: 1-3/4x11-7/8 VERSA-LAM 2.0 3100 SP 2 ply PASSES DESIGN CHECKS Design assumes continuous lateral bracing along the top chord. Design assumes continuous lateral bracing along the bottom chord. Allowable Stress Design Actual Allowable Capacity Location Loading Positive Moment 13159.# 24466.# 53% 6.44' Total Load D+S Shear 3635.# 9081.# 40% 11.89' Total Load D+S TL Deflection 0.3559" 0.6057" L/408 6.44' Total Load D+S LL Deflection 0.2602" 0.4038" L/558 6.44' Total Load S Control: LL Deflection DOLs: Live=100% Snow=115% Roof=125% Wind=160% Manufacturer's installation guide MUST be consulted for multi-ply connection details and alternatives Minimum bearing length requirements at hangared connections depend on the connection style and are not included in this design. CS Structure™ 2.14.50 [Build 4] kmBeamEngine 4.13.4.1 Materials Database 1530 JazabEd167MainStLeeds101515 -10-23-15 1:50pm 2 of 2 All product names are trademarks of their respective owners Copyright (C) 2015 by Simpson Strong-Tie Company Inc. ALL RIGHTS RESERVED.**Passing is defined as when the member, floor joist, beam or girder, shown on this drawing meets applicable design criteria for Loads, Loading Conditions, and Spans listed on this sheet. The design must be reviewed by a qualified designer or design professional as required for approval. This design assumes product installation according to the manufacturer`s specifications. Doug Hodgins rk Miles Inc. 21 West St. West Hatfield Ma. Member Data Description: CalcG2 Member Type: Girder Application: Roof Comments:Top Lateral Bracing: Continuous Slope: 0.00 / 12 Bottom Lateral Bracing: Continuous Standard Load: Moisture Condition: Dry Building Code: IBC/IRC Live Load: 0 PLF Deflection Criteria: L/360 live, L/240 total Dead Load: 0 PLF Deck Connection: Nailed Member Weight: 11.7 PLF Filename: C:\KMW\JOBS\ Other Loads Type (Description) Side Begin End Trib. Width Other Start End Dead Start End Category Replacement Uniform (PLF) Top 0' 0.00" 10' 3.50" 0 55 Live Replacement Uniform (PLF) Top 0' 0.00" 10' 3.50" 0 55 Live Replacement Uniform (PLF) Top 0' 0.00" 10' 3.50" 161 0 Snow Replacement Uniform (PLF) Top 0' 0.00" 10' 3.50" 161 0 Snow 1 2 10 3 8 10 3 8 Bearings and Reactions Input Min Gravity Gravity Location Type Material Length Required Reaction Uplift 1 0' 0.000" Wall SPF Plate (425psi) N/A 1.500" 2135# -- 2 10' 3.500" Girder SPF Plate (425psi) N/A N/A 2135# -- Maximum Load Case Reactions Used for applying point loads (or line loads) to carrying members Live Snow Dead 1 4# 1547# 587# 2 4# 1547# 587# Design spans 9' 7.375" Product: 1-3/4x11-7/8 VERSA-LAM 2.0 3100 SP 2 ply PASSES DESIGN CHECKS Design assumes continuous lateral bracing along the top chord. Design assumes continuous lateral bracing along the bottom chord. Allowable Stress Design Actual Allowable Capacity Location Loading Positive Moment 5131.# 24466.# 20% 5.19' Total Load D+S Shear 1695.# 9081.# 18% 0.4' Total Load D+S TL Deflection 0.0874" 0.4807" L/999+ 5.19' Total Load D+S LL Deflection 0.0634" 0.3205" L/999+ 5.19' Total Load S Control: Positive Moment DOLs: Live=100% Snow=115% Roof=125% Wind=160% Manufacturer's installation guide MUST be consulted for multi-ply connection details and alternatives Minimum bearing length requirements at hangared connections depend on the connection style and are not included in this design.