Loading...
10D-019 CS Beam in loft area CalcCS Structureâ„¢ 2.14.50 [Build 4] kmBeamEngine 4.13.4.1 Materials Database 1530 JazabEd167MainStLeeds101515 -10-23-15 1:54pm 1 of 1 All product names are trademarks of their respective owners Copyright (C) 2015 by Simpson Strong-Tie Company Inc. ALL RIGHTS RESERVED.**Passing is defined as when the member, floor joist, beam or girder, shown on this drawing meets applicable design criteria for Loads, Loading Conditions, and Spans listed on this sheet. The design must be reviewed by a qualified designer or design professional as required for approval. This design assumes product installation according to the manufacturer`s specifications. Doug Hodgins rk Miles Inc. 21 West St. West Hatfield Ma. Member Data Description: CalcG3 Member Type: Girder Application: Floor Comments:Top Lateral Bracing: Continuous Bottom Lateral Bracing: Continuous Standard Load: Moisture Condition: Dry Building Code: IBC/IRC Live Load: 0 PLF Deflection Criteria: L/360 live, L/240 total Dead Load: 0 PLF Deck Connection: Nailed Member Weight: 17.6 PLF Filename: C:\KMW\JOBS\ Other Loads Type (Description) Side Begin End Trib. Width Other Start End Dead Start End Category Replacement Uniform (PLF) Top 0' 0.00" 4' 0.00" 0 63 Live Replacement Uniform (PLF) Top 4' 0.00" 12' 3.00" 125 63 Live Replacement Uniform (PLF) Top 12' 3.00" 19' 0.88" 52 26 Live Point (LBS) Top 0' 4.63" 5 821 Live Point (LBS) Top 0' 4.63" 1639 0 Snow Point (LBS) Top 12' 2.25" 103 167 Live 1 2 19 0 14 19 0 14 Bearings and Reactions Input Min Gravity Gravity Location Type Material Length Required Reaction Uplift 1 0' 0.000" Wall SPF Plate (425psi) N/A 1.500" 3333# -- 2 19' 0.875" Wall SPF Plate (425psi) N/A 1.500" 1426# -- Maximum Load Case Reactions Used for applying point loads (or line loads) to carrying members Live Snow Dead 1 702# 1639# 1577# 2 778# 0# 647# Design spans 18' 5.625" Product: 1-3/4x11-7/8 VERSA-LAM 2.0 3100 SP 3 ply PASSES DESIGN CHECKS NOTE: Pass-thru framing is required at point loads over bearings. Design assumes continuous lateral bracing along the top chord. Design assumes continuous lateral bracing along the bottom chord. Allowable Stress Design Actual Allowable Capacity Location Loading Positive Moment 8036.# 33189.# 24% 9.62' Total Load D+L Shear 1375.# 11845.# 11% 0.4' Total Load D+L TL Deflection 0.3286" 0.9234" L/674 9.62' Total Load D+L LL Deflection 0.1808" 0.6156" L/999+ 9.62' Total Load L Control: TL Deflection DOLs: Live=100% Snow=115% Roof=125% Wind=160% Design assumes a repetitive member use increase in bending stress: 4 % Manufacturer's installation guide MUST be consulted for multi-ply connection details and alternatives Point loads over bearings are NOT included in the Design calculations, but ARE included in the Reaction table