Loading...
10D-019 1st floor Beam CalcsCS Structure™ 2.14.50 [Build 4] kmBeamEngine 4.13.4.1 Materials Database 1530 JazabEd167MainStLeeds101515 -10-23-15 2:08pm 1 of 4 All product names are trademarks of their respective owners Copyright (C) 2015 by Simpson Strong-Tie Company Inc. ALL RIGHTS RESERVED.**Passing is defined as when the member, floor joist, beam or girder, shown on this drawing meets applicable design criteria for Loads, Loading Conditions, and Spans listed on this sheet. The design must be reviewed by a qualified designer or design professional as required for approval. This design assumes product installation according to the manufacturer`s specifications. Doug Hodgins rk Miles Inc. 21 West St. West Hatfield Ma. Member Data Description: CalcG3 Member Type: Girder Application: Floor Comments:Top Lateral Bracing: Continuous Bottom Lateral Bracing: Continuous Standard Load: Moisture Condition: Dry Building Code: IBC/IRC Live Load: 0 PLF Deflection Criteria: L/360 live, L/240 total Dead Load: 0 PLF Deck Connection: Nailed Member Weight: 36.0 PLF Filename: C:\KMW\JOBS\ Other Loads Type (Description) Side Begin End Trib. Width Other Start End Dead Start End Category Replacement Uniform (PLF) Top 0' 0.00" 9' 10.00" -138 -18 Live Replacement Uniform (PLF) Top 0' 0.00" 10' 1.06" 310 77 Live Replacement Uniform (PLF) Top 10' 1.06" 17' 11.75" 624 213 Live Replacement Uniform (PLF) Top 17' 11.75" 19' 11.75" 858 317 Live Replacement Uniform (PLF) Top 19' 10.00" 20' 10.63" 136 101 Live Replacement Uniform (PLF) Top 19' 11.75" 23' 6.00" 584 197 Live Replacement Uniform (PLF) Top 20' 10.63" 23' 6.00" 136 101 Live Replacement Uniform (PLF) Top 23' 6.00" 30' 1.00" -138 -18 Live Replacement Uniform (PLF) Top 23' 6.00" 30' 1.00" 310 77 Live Point (LBS) Top 9' 8.50" 1861 582 Live Point (LBS) Top 17' 11.75" 0 24 Live Point (LBS) Top 19' 11.75" 0 24 Live Point (LBS) Top 23' 6.00" 935 358 Live Point (LBS) Top 29' 8.38" 935 358 Live 1 2 3 4 9 10 0 10 0 0 10 3 0 30 1 0 Bearings and Reactions Input Min Gravity Gravity Location Type Material Length Required Reaction Uplift 1 0' 0.000" Girder SPF Plate (425psi) N/A N/A 1743# -524# 2 9' 10.000" Wall SPF Plate (425psi) N/A 2.430" 9545# -- 3 19' 10.000" Wall SPF Plate (425psi) N/A 3.905" 11435# -12# 4 30' 1.000" Wall SPF Plate (425psi) N/A 1.500" 3659# -- Maximum Load Case Reactions Used for applying point loads (or line loads) to carrying members Live Dead 1 1374# 369# 2 7156# 2389# 3 8108# 3327# 4 2739# 920# Design spans 9' 4.750" 10' 0.000" 9' 10.375" Product: AFP Treated Beam 3 1/2 X 18 2 ply PASSES DESIGN CHECKS NOTE: Pass-thru framing is required at point loads over bearings. Design assumes continuous lateral bracing along the top chord. Design assumes continuous lateral bracing along the bottom chord. Review gravity uplift reaction force of 524lbs at bearing 1 and ensure that the structure can resist appropriately. Allowable Stress Design Actual Allowable Capacity Location Loading Positive Moment 6612.# 74250.# 8% 24.27' Odd Spans D+L Negative Moment 9942.# 74250.# 13% 19.83' Adjacent 2 D+L Shear 4210.# 24750.# 17% 19.84' Adjacent 2 D+L TL Deflection 0.0238" 0.4932" L/999+ 24.77' Odd Spans D+L LL Deflection 0.0192" 0.3288" L/999+ 24.77' Odd Spans L CS Structure™ 2.14.50 [Build 4] kmBeamEngine 4.13.4.1 Materials Database 1530 JazabEd167MainStLeeds101515 -10-23-15 2:08pm 2 of 4 All product names are trademarks of their respective owners Copyright (C) 2015 by Simpson Strong-Tie Company Inc. ALL RIGHTS RESERVED.**Passing is defined as when the member, floor joist, beam or girder, shown on this drawing meets applicable design criteria for Loads, Loading Conditions, and Spans listed on this sheet. The design must be reviewed by a qualified designer or design professional as required for approval. This design assumes product installation according to the manufacturer`s specifications. Doug Hodgins rk Miles Inc. 21 West St. West Hatfield Ma. Control: Shear DOLs: Live=100% Snow=115% Roof=125% Wind=160% Manufacturer's installation guide MUST be consulted for multi-ply connection details and alternatives Point loads over bearings are NOT included in the Design calculations, but ARE included in the Reaction table Minimum bearing length requirements at hangared connections depend on the connection style and are not included in this design. CS Structure™ 2.14.50 [Build 4] kmBeamEngine 4.13.4.1 Materials Database 1530 JazabEd167MainStLeeds101515 -10-23-15 2:08pm 3 of 4 All product names are trademarks of their respective owners Copyright (C) 2015 by Simpson Strong-Tie Company Inc. ALL RIGHTS RESERVED.**Passing is defined as when the member, floor joist, beam or girder, shown on this drawing meets applicable design criteria for Loads, Loading Conditions, and Spans listed on this sheet. The design must be reviewed by a qualified designer or design professional as required for approval. This design assumes product installation according to the manufacturer`s specifications. Doug Hodgins rk Miles Inc. 21 West St. West Hatfield Ma. Member Data Description: CalcG4 Member Type: Girder Application: Floor Comments:Top Lateral Bracing: Continuous Bottom Lateral Bracing: Continuous Standard Load: Moisture Condition: Dry Building Code: IBC/IRC Live Load: 0 PLF Deflection Criteria: L/360 live, L/240 total Dead Load: 0 PLF Deck Connection: Nailed Member Weight: 17.6 PLF Filename: C:\KMW\JOBS\ Other Loads Type (Description) Side Begin End Trib. Width Other Start End Dead Start End Category Replacement Uniform (PLF) Top 0' 0.00" 18' 7.00" 27 7 Live Replacement Uniform (PLF) Top 0' 0.00" 18' 7.00" 27 7 Live Point (LBS) Top 0' 4.63" 1353 0 Snow Point (LBS) Top 0' 4.63" 3719 1869 Live Point (LBS) Top 0' 4.63" 166 0 Snow Point (LBS) Top 0' 4.63" 28 192 Live Point (LBS) Top 3' 11.88" 822 229 Live Point (LBS) Top 18' 2.38" 28 129 Live Point (LBS) Top 18' 2.38" 0 162 Live Point (LBS) Top 18' 2.38" 166 0 Snow Point (LBS) Top 18' 2.38" 275 411 Live Point (LBS) Top 18' 2.38" 698 0 Snow Point (LBS) Top 18' 2.38" 988 0 Snow Point (LBS) Top 18' 2.38" 2369 1374 Live 1 2 3 7 5 2 11 1 14 18 7 0 Bearings and Reactions Input Min Gravity Gravity Location Type Material Length Required Reaction Uplift 1 0' 0.000" Wall SPF Plate (425psi) N/A 1.500" 6548# -- 2 7' 5.125" Wall SPF Plate (425psi) N/A 1.500" 1640# -- 3 18' 7.000" Wall SPF Plate (425psi) N/A 1.500" 5775# -- Maximum Load Case Reactions Used for applying point loads (or line loads) to carrying members Live Snow Dead 1 4257# 1520# 2215# 2 1138# 0# 503# 3 2916# 1852# 2198# Design spans 7' 0.500" 10' 9.250" Product: 1-3/4x11-7/8 VERSA-LAM 2.0 3100 SP 3 ply PASSES DESIGN CHECKS NOTE: Pass-thru framing is required at point loads over bearings. Design assumes continuous lateral bracing along the top chord. Design assumes continuous lateral bracing along the bottom chord. Allowable Stress Design Actual Allowable Capacity Location Loading Positive Moment 1844.# 33189.# 5% 3.99' Odd Spans D+L Negative Moment 1498.# 33189.# 4% 7.43' Total Load D+L Shear 964.# 11845.# 8% 6.72' Total Load D+L TL Deflection 0.0084" 0.3521" L/999+ 3.91' Odd Spans D+L LL Deflection 0.0070" 0.2347" L/999+ 3.91' Odd Spans L CS Structure™ 2.14.50 [Build 4] kmBeamEngine 4.13.4.1 Materials Database 1530 JazabEd167MainStLeeds101515 -10-23-15 2:08pm 4 of 4 All product names are trademarks of their respective owners Copyright (C) 2015 by Simpson Strong-Tie Company Inc. ALL RIGHTS RESERVED.**Passing is defined as when the member, floor joist, beam or girder, shown on this drawing meets applicable design criteria for Loads, Loading Conditions, and Spans listed on this sheet. The design must be reviewed by a qualified designer or design professional as required for approval. This design assumes product installation according to the manufacturer`s specifications. Doug Hodgins rk Miles Inc. 21 West St. West Hatfield Ma. Control: Shear DOLs: Live=100% Snow=115% Roof=125% Wind=160% Design assumes a repetitive member use increase in bending stress: 4 % Manufacturer's installation guide MUST be consulted for multi-ply connection details and alternatives Point loads over bearings are NOT included in the Design calculations, but ARE included in the Reaction table