Loading...
10D-019 1st floor Beam CalcCS Structureâ„¢ 2.14.50 [Build 4] kmBeamEngine 4.13.4.1 Materials Database 1530 JazabEd167MainStLeeds101515 -10-23-15 2:08pm 1 of 2 All product names are trademarks of their respective owners Copyright (C) 2015 by Simpson Strong-Tie Company Inc. ALL RIGHTS RESERVED.**Passing is defined as when the member, floor joist, beam or girder, shown on this drawing meets applicable design criteria for Loads, Loading Conditions, and Spans listed on this sheet. The design must be reviewed by a qualified designer or design professional as required for approval. This design assumes product installation according to the manufacturer`s specifications. Doug Hodgins rk Miles Inc. 21 West St. West Hatfield Ma. Member Data Description: CalcB7 Member Type: Beam Application: Floor Comments:Top Lateral Bracing: Continuous Bottom Lateral Bracing: Continuous Standard Load: Moisture Condition: Dry Building Code: IBC/IRC Live Load: 0 PLF Deflection Criteria: L/360 live, L/240 total Dead Load: 0 PLF Deck Connection: Nailed Member Weight: 17.6 PLF Filename: C:\KMW\JOBS\ Other Loads Type (Description) Side Begin End Trib. Width Other Start End Dead Start End Category Replacement Uniform (PLF) Top 0' 0.00" 10' 2.00" 478 120 Live Replacement Uniform (PLF) Top 10' 2.00" 14' 4.50" 460 172 Live Replacement Uniform (PLF) Top 14' 4.50" 18' 3.75" 229 57 Live Replacement Uniform (PLF) Top 18' 3.75" 20' 2.00" 229 57 Live Replacement Uniform (PLF) Top 20' 2.00" 21' 2.63" 478 120 Live Replacement Uniform (PLF) Top 21' 2.63" 23' 10.00" 478 120 Live Replacement Uniform (PLF) Top 23' 10.00" 30' 5.00" 478 120 Live Point (LBS) Top 0' 7.13" 546 320 Live Point (LBS) Top 10' 0.50" 1435 476 Live Point (LBS) Top 14' 4.50" 1695 1166 Live Point (LBS) Top 20' 3.75" 0 24 Live Point (LBS) Top 30' 0.38" 1465 849 Live 1 2 3 4 10 2 0 10 0 0 10 3 0 30 5 0 Bearings and Reactions Input Min Gravity Gravity Location Type Material Length Required Reaction Uplift 1 0' 0.000" Wall SPF Plate (425psi) N/A 1.508" 3364# -- 2 10' 2.000" Wall SPF Plate (425psi) N/A 4.690" 10465# -- 3 20' 2.000" Wall SPF Plate (425psi) N/A 3.219" 7183# -- 4 30' 5.000" Wall SPF Plate (425psi) N/A 2.199" 4907# -- Maximum Load Case Reactions Used for applying point loads (or line loads) to carrying members Live Dead 1 2618# 746# 2 7652# 2814# 3 5335# 1848# 4 3584# 1323# Design spans 9' 6.875" 10' 0.000" 9' 10.375" Product: 1-3/4x11-7/8 VERSA-LAM 2.0 3100 SP 3 ply PASSES DESIGN CHECKS Design assumes continuous lateral bracing along the top chord. Design assumes continuous lateral bracing along the bottom chord. Allowable Stress Design Actual Allowable Capacity Location Loading Positive Moment 7431.# 33189.# 22% 14.38' Even Spans D+L Negative Moment 8185.# 33189.# 24% 10.17' Adjacent 1 D+L Shear 4112.# 11845.# 34% 10.18' Adjacent 1 D+L TL Deflection 0.0614" 0.5000" L/999+ 14.67' Even Spans D+L LL Deflection 0.0526" 0.3288" L/999+ 25.1' Odd Spans L Control: Shear DOLs: Live=100% Snow=115% Roof=125% Wind=160% Design assumes a repetitive member use increase in bending stress: 4 % Manufacturer's installation guide MUST be consulted for multi-ply connection details and alternatives