2017-01-25 L1 Ramp & Storefronts - STAMPEDA-1PROPOSED L1 RAMP AND STOREFRONTS
DEMO PLAN - LEVEL L1 SCALE: AS NOTED
ON DRAWINGS
VERIFY ALL DIMENSIONS IN THE FIELD
L1 ELEV.
0'-0"
L1 ELEV.
0'-0"
DEMO PORTION OF WALL AS NECESSARY FOR INSTALLATION OF
NEW WINDOW
FLOORING & CEILING IN THIS AREA TO
BE REVIEWED AFTER WALL DEMO, FOR
EXTENT OF REPAIR/REPLACEMENT
EXISTING PIPING
TO REMAIN
OUTLINE OF
CONTRACTOR WORK AREA
EXISTING TIMBER COLUMNS TO REMAIN
OUTLINE OFCONTRACTOR
WORK AREA
NO WORK IN
THIS AREA
NO WORK IN
THIS AREA HERRELL'S ELEV.
-3'-0"
STE. 050 LOWER ELEV.
-1'-6"
STE. 080 UPPER ELEV.
2'-6"
L1 ELEV.
0'-0"
UP
DN
DN
SUITE 050
SUITE 080
5'-3 1/2"16'-4 3/4"11"4 3/4"6'-9 3/4"1'-1 1/4"5'-9"DEMO FLOOR ATBOTTOM OF RAMP -SEE A-10
FLOORING & CEILING IN THIS AREA TO
BE REVIEWED AFTER WALL DEMO, FOR EXTENT OF REPAIR/REPLACEMENT
EXISTING HISTORICSTAIRS
6"EXISTING COLUMN SURROUND
TO REMAIN
DEMO EXISTING BUILT-IN COUNTERS
DEMO PORTIONOF EXISTING
HALF WALL 1'-0"
UP
EXISTINGRAMP15'-0"
02
15'-0"
03
14'-11 1/2"
0401
UPTHIS WALL TO BEDEMO’ED DURINGBATHROOM PROJECT
41'-0"
NEW RAMP OUTLINE
DN
WOMEN'S RM
MEN'S RM4"5'-2"1
A-3
1
A-4
1
A-5
DEMO PLAN - LEVEL L1
3/16" = 1'-0"1
NOTES:
1. DEMO EXISTING WALL, DOORS, STAIRS AS NOTED WITHIN WORK AREA.2. PROTECT ADJACENT FINISHES, WINDOWS, COLUMNS, PIPING, ETC. TO REMAIN DURING CONSTRUCTION.
DATE: 1/9/17
EX. PIPING AT ENTRYWAYS EX. PIPING AT HALL
PERMIT SET - FOR CONSTRUCTION
196 Pleasant St.
Northampton
MA 01060
413-585-0641
REGISTERED ARCHITECT, COMMONWEALTH OF MASSACHUSETTS
This drawing is not intended nor shall it be used for con-struction purposes unless the signed professional seal of a registered architect employed by Thomas Douglas
Architects is affixed in the space below. The Architect shall be deemed the author of these documents and
shall retain all common law, statutory and other reserved rights, including the copyright.
THOMAS DOUGLAS ARCHITECTS, INC.
A-2PROPOSED L1 RAMP AND STOREFRONTS
DEMO PLAN - LEVEL L2 SCALE: AS NOTED
ON DRAWINGS
VERIFY ALL DIMENSIONS IN THE FIELD
UP
UP
SHELF SHELF3'-0" X 8'-0"
WORK TABLE 3'-0" X 7'-0"WORK TABLETABLEUP
8'-0"BOILER ROOM
UTILITY/
STORAGE
ELEC. ROOM
WORK ROOM
6'-8" X 2'-4 1/2"
UTILITY SINKS6'-0 1/2"STORAGE ROOM
L1 CORRIDOR
UP
UP3'-6 1/2"12'-1 1/2"28'-10 1/2"
RAMP OUTLINE ABOVE
EXISTING MASONRYWALL & COLUMNS
RELOCATE EX.SHELF DURINGCONTRUCTION
EXISTING MASONRY
WALL
EX. BEAM ABOVE
RAMP OUTLINE
ABOVE
OUTLINE OFCONTRACTORWORK AREA
OUTLINE OF
CONTRACTOR
WORK AREA
NO WORK ON BOILER ROOM PLASTER
WALL IN THIS CONTRACT.
EXISTING METAL STUD, GWB, & PLASTER WALL. DEMO
GWB TO METAL STUDS @ UTIL./STORAGE ROOM.
REMOVE SINK,SHELVES, & ALL PIPING
IN THIS AREA. STORE
FOR REINSTALLATION.
15'-0"
02
15'-0"
03
14'-11 1/2"
01 04
OUTLINE OFCONTRACTOR
WORK AREA
2'-1"2'-1"
SAWCUT & REMOVE PORTION OF CONCRETE SLAB FOR INSTALLATION
OF NEW PIER FOOTING
DEMO
PORTION OF WALL & CEILING IN
THIS AREA.
SEE SHEETS
A-15 & A-16.
1
A-3
1
A-4
1
A-5
DEMO PLAN - LEVEL L2 (FLOOR DIRECTLY BELOW PROPOSED RAMP)
3/16" = 1'-0"1
DATE: 1/9/17
196 Pleasant St.
Northampton
MA 01060
413-585-0641
REGISTERED ARCHITECT, COMMONWEALTH OF MASSACHUSETTS
This drawing is not intended nor shall it be used for con-struction purposes unless the signed professional seal of a registered architect employed by Thomas Douglas
Architects is affixed in the space below. The Architect shall be deemed the author of these documents and
shall retain all common law, statutory and other reserved rights, including the copyright.
THOMAS DOUGLAS ARCHITECTS, INC.
PERMIT SET - FOR CONSTRUCTION
A-3PROPOSED L1 RAMP AND STOREFRONTS
DEMO SECTIONS/ELEVATIONS SCALE: AS NOTED
ON DRAWINGS
VERIFY ALL DIMENSIONS IN THE FIELD
EX. 11 1/2”x14” ± BEAM (PROJECTS
BELOW TIN CLG)12'-2"±EX. TIN CEILING ON MTL LATH, PLASTER &
WOOD FURRING
11'-9"±VARIESEX. 11 1/2”x14” ±
BEAM
(BEYOND)
EX. STAIRS TO BE REMOVED10'-7"EX. PIPE TO REMAIN,
PROTECT IN PLACE
UTILTY/STORAGE ROOM
CAREFULLY REMOVE ALL WALL MOUNTED PIPES, CONDUITS, SHELVING & EQUIPMENT, STORE FOR REINSTALLATION. DEMO
GWB, ON THIS SIDE OF WALL ONLY, STUDS TO REMAIN. ALL PIPES
THAT PENETRATE WALL TO REMAIN IN PLACE.
DEMO EX. DOOR & CASING.
EX. WINDOW & CASING TO REMAIN.
PROTECT DURING CONSTRUCTION.
EX. HALF WALL @ STAIR
DEMO PLEXIGLAS WINDOW &
WOOD CAP
DEMO DOOR FRAME,
LOWER WINDOW &
FRAME
EX. GWB OVER MTLSTUDS
EX. BRICK WALL
DEMO EX.
WINDOW,CASING & WALLAS INDICATED
EX. BRICK PIER, TYP
WORK ROOM STORAGE ROOM
EX. PIPING TO REMAIN. PROTECT
IN PLACE.
EXISTINGOPENING TOBEYOND
SUITE 080
EX. WINDOW & CASING TO REMAIN.
PROTECT DURING CONSTRUCTION.TYP.
EXISTING
STAIRS TO
LEVEL L1
DEMO EX. BRICK AS
NECESSARY TO ACCOMMODATE NEW
RAMP STRINGERS
02 03 0401
DEMO EX. FLOORING &2X14± JOISTS IN THE AREA
OF NEW RAMP AS
INDICATED EXISTING
STAIRS TOLEVEL L1
1'-0"
EXISTING STOREFRONT TO REMAIN STOREFRONT TO BE DEMOLISHED EXISTING STOREFRONT TO REMAIN
HERRELL'S
10'-6" ±
LEVEL L1
13'-6" ±
LEVEL L2
0'-0"
EXISTING LONGITUDINAL SECTION
3/16" = 1'-0"1
DATE: 1/9/17
196 Pleasant St.
Northampton
MA 01060
413-585-0641
REGISTERED ARCHITECT, COMMONWEALTH OF MASSACHUSETTS
This drawing is not intended nor shall it be used for con-struction purposes unless the signed professional seal of a registered architect employed by Thomas Douglas
Architects is affixed in the space below. The Architect shall be deemed the author of these documents and
shall retain all common law, statutory and other reserved rights, including the copyright.
THOMAS DOUGLAS ARCHITECTS, INC.
PERMIT SET - FOR CONSTRUCTION
A-4PROPOSED L1 RAMP AND STOREFRONTS
DEMO SECTIONS/ELEVATIONS SCALE: AS NOTED
ON DRAWINGS
VERIFY ALL DIMENSIONS IN THE FIELD
EXISTING
TEMPERED
GLASS
EX. STAIRS TO
BE REMOVED
EX. DUCT TO REMAIN,
PROTECT IN PLACE ±10'-7"UTILTY/STORAGE ROOM
EX. UTIL. SINKS
SHELVES
CAREFULLY REMOVE ALL WALL MOUNTED PIPES, CONDUITS, SHELVING & EQUIPMENT, STORE FOR REINSTALLATION. DEMO
GWB, ON THIS SIDE OF WALL ONLY, STUDS TO REMAIN. ALL PIPES
THAT PENETRATE WALL TO REMAIN IN PLACE.
PAPERTOWELSDISP.
SHELVES
REMOVE SECTIONS OF EX. TIN & PLYWOOD CEILING AS
NECESSARY FOR INSTALLATION
OF NEW BLOCKING
EXISTING STOREFRONT TO REMAIN STOREFRONT TO BE DEMOLISHED
EXISTING
OPENING TO
BEYONDSUITE 050DEMO EX.
FLOORING
2X14± JOISTS
AS INDICATEDAT AREA OFRAMP
ALL EXISTING UTILITIES @ CEILING TO REMAIN OPERATIONAL DURING DEMO &
CONSTRUCTION. PROVIDE TEMPORARY SUPPORT AS
NECESSARY FOR INSTALLATION & BLOCKING.
WORK ROOM
CORRIDORSTORAGE ROOM
EX. BRICK WALL
EX. TIN CEILING, HEIGHT VARIES.
EX. STOREFRONT WALL
SUPPORT POST
DEMO EX. STOREFRONT
WALL SUPPORT POST
DEMO PORTIONS OF EXISTING CLG ONLY AS NECESSARY TO
ATTACH NEW SUPPORT POSTS TO EX. FRAMING ABOVE.EX. DROPPED BEAM.EX. PLUMBING OR SPRINKLER LINES
EX. 2x14 FLOOR JOISTS.
EX. GWB WALL
TO
CORNUCOPIATO HERRELL’S
HERRELL'S
10'-6" ±
LEVEL L1
13'-6" ±
LEVEL L2
0'-0"
DEMO SECTION
3/16" = 1'-0"2
DATE: 1/9/17
196 Pleasant St.
Northampton
MA 01060
413-585-0641
REGISTERED ARCHITECT, COMMONWEALTH OF MASSACHUSETTS
This drawing is not intended nor shall it be used for con-struction purposes unless the signed professional seal of a registered architect employed by Thomas Douglas
Architects is affixed in the space below. The Architect shall be deemed the author of these documents and
shall retain all common law, statutory and other reserved rights, including the copyright.
THOMAS DOUGLAS ARCHITECTS, INC.
PERMIT SET - FOR CONSTRUCTION
A-5PROPOSED L1 RAMP AND STOREFRONTS
DEMO SECTIONS/ELEVATIONS SCALE: AS NOTED
ON DRAWINGS
VERIFY ALL DIMENSIONS IN THE FIELD
BOILER ROOM
EX. 11 1/2” x 14” ± BEAM
(SUPPORTS FLOOR JOISTS@ LOWER LEVEL OF RAMP)
EX. 11 1/2” x 16” ±
BEAM
COL. 2
EX. STEAM PIPE RISER TO REMAIN.
PROTECT IN PLACE.
UTILTY/STORAGE ROOM
REMOVE PORTION OF EX. FLOOR FOR
NEW RAMP
EXISTING STOREFRONT WALLS TO BE DEMO’ED.
DEMO EXISTING
CURVED
PLEXIGLAS
SKYLIGHTS &
WOOD FRAME
DEMO EXISTING
RAILING/ WALL
CAP. REMOVE &
REINSTALL METAL RAILING.
EXISTING WINDOWS &
FRAMES TO REMAIN.
EXISTING HALF WALL &
STAIRS TO REMAIN
UTIL.SINKS
SUITE 080 HALLWAY (RAMP)SUITE 050
SAWCUT &REMOVE PORTION
OF FLOOR JOISTS
FLOOR JOISTS TO REMAIN EX. FLOOR JOISTS TO REMAIN. SHALL BERESUPPORTED BY NEW BEARING WALL BELOW.
DEMO EX. GWB,
METAL STUDS
TO REMAIN.
SAWCUT EX. TIN CEILING IN UTLITY/STORAGE ROOM ONLY AS
NECESSARY FOR INSTALLATION OF
NEW PSL POSTS.
DEMO PORTION OF EX. GWB WALL ASNECESSARY FOR CONSTRUCTION OF NEWLOAD-BEARING WALL.
EXISTING
OPENING TO
BEYOND
A
HERRELL'S
10'-6" ±
LEVEL L1
13'-6" ±
LEVEL L2
0'-0"
DEMO SECTION
3/16" = 1'-0"3
DATE: 1/9/17
196 Pleasant St.
Northampton
MA 01060
413-585-0641
REGISTERED ARCHITECT, COMMONWEALTH OF MASSACHUSETTS
This drawing is not intended nor shall it be used for con-struction purposes unless the signed professional seal of a registered architect employed by Thomas Douglas
Architects is affixed in the space below. The Architect shall be deemed the author of these documents and
shall retain all common law, statutory and other reserved rights, including the copyright.
THOMAS DOUGLAS ARCHITECTS, INC.
PERMIT SET - FOR CONSTRUCTION
A-6PROPOSED L1 RAMP AND STOREFRONTS
PROPOSED PLAN - LEVEL L1 SCALE: AS NOTED
ON DRAWINGS
UP
UP
DN
SUITE 050
SUITE 080
EXISTING STAIRS
EXISTING HISTORICSTAIRS
2'-0 1/8"
UP
EXISTINGRAMP15'-0"
02
15'-0"
03
14'-11 1/2"
0401
UPDN WOMEN'S RM
MEN'S RM
A
RAMP OUTLINE
DNDN
15'-0" HORIZONTAL 1'-0"
MIN.
21'-0" HORIZONTAL5'-0"
LEVEL
LANDING
RAMP 1:12 MAX.
1 A-6TYP.EX. STOREFRONT GLAZING WITH NEW
SAFETY FILM @ SELECT LOCATIONS.
SEE ELEVATIONS.
EX. STOREFRONT GLAZING WITH
NEW SAFETY FILM
EX. STOREFRONT GLAZING
NEW STOREFRONT GLAZING
3'-0"
NEW STOREFRONT GLAZING
NEW
STORE
F
R
O
N
T
NEW STEEL HANDRAILS BOLTED
INTO WALL & WALL COLUMNS. PROVIDE SOLID BLOCKING BEHIND ALL CONNECTIONS.±5'-0"(44" MIN. REQ.)NEW CUSTOM WOOD SLIDING DOOR - WHITE OAK & TEMPERED
GLAZING.
EX. WOOD COLUMN SURROUND TO REMAIN.
PROTECT IN PLACE.
RAMP 1:12 MAX.
NEW HALF WALL SEGMENT,
MATCH EXISTING FINISH.40.00°4"5'-0"NEW STOREFRONT GLAZING3'-10"3'-9"3'-9"3'-9"3'-10"
3'-10"3'-9"3'-10"2'-6"2'-6"3'-9"3'-9"NEW STOREFRONTGLAZING40.00
°
TO CORNUCOPIA
TO HERRELL'S
GLAZIN
G
1
A-12
1
A-10
1
A-11
1A-17
2
A-17
PROPOSED PLAN - LEVEL L1
3/16" = 1'-0"1
VERIFY ALL DIMENSIONS IN THE FIELD
DATE: 1/9/17
196 Pleasant St.
Northampton
MA 01060
413-585-0641
REGISTERED ARCHITECT, COMMONWEALTH OF MASSACHUSETTS
This drawing is not intended nor shall it be used for con-struction purposes unless the signed professional seal of a registered architect employed by Thomas Douglas
Architects is affixed in the space below. The Architect shall be deemed the author of these documents and
shall retain all common law, statutory and other reserved rights, including the copyright.
THOMAS DOUGLAS ARCHITECTS, INC.
PERMIT SET - FOR CONSTRUCTION
SHELF SHELF3'-0" X 8'-0"
WORK TABLE 3'-0" X 7'-0"WORK TABLETABLE8'-0"BOILER ROOM
UTILITY/
STORAGE
ELEC. ROOM
WORK ROOM
6'-8" X 2'-4 1/2"
UTILITY SINKS6'-0 1/2"STORAGE ROOM
L1 CORRIDOR
UP
UP3'-6 1/2"12'-1 1/2"28'-10 1/2"
INSTALL NEW FRAMING AT
DEMO’ED SKYLIGHT
OPENINGS & PATCH & PAINT
GWB @ AREA OF DEMO’EDSKYLIGHT
INSTALL TEMPORARY
SUPPORTS FOR TIN CEILING
ASSEMBLY IN BOILER ROOM.
NEW 3 1/2”x3 1/2” PSL STUDS BELOW
EACH EX. JOIST END, WITH 3/4”
PLYWOOD SHEATHING & FRP IN UTIL./STORAGE ROOM. SEE NOTE 1.
EX. METAL STUDS & PLASTER
IN BOILER ROOM TO REMAIN.
15'-0"
02
15'-0"
03
14'-11 1/2"
0401
OUTLINE OF RAMP
ABOVE.
NEW 3-1/2” x 3-1/2”
PSL POST ON
SIMPSON PB44
POST BASE EMBEDDED IN NEW 24”x24”x8”
CONCRETE PIER
2'-1"2'-1"
A
1
A-12
1
A-10
1A-11
A-7PROPOSED L1 RAMP AND STOREFRONTS
PROPOSED PLAN - LEVEL L2 SCALE: AS NOTED
ON DRAWINGS
VERIFY ALL DIMENSIONS IN THE FIELD
PROPOSED PLAN - LEVEL L2 (FLOOR DIRECTLY BELOW PROPOSED RAMP)
3/16" = 1'-0"1
DATE: 1/9/17
196 Pleasant St.
Northampton
MA 01060
413-585-0641
REGISTERED ARCHITECT, COMMONWEALTH OF MASSACHUSETTS
This drawing is not intended nor shall it be used for con-struction purposes unless the signed professional seal of a registered architect employed by Thomas Douglas
Architects is affixed in the space below. The Architect shall be deemed the author of these documents and
shall retain all common law, statutory and other reserved rights, including the copyright.
THOMAS DOUGLAS ARCHITECTS, INC.
PERMIT SET - FOR CONSTRUCTION
A-8PROPOSED L1 RAMP AND STOREFRONTS
PROPOSED RCP - LEVEL L1 SCALE: AS NOTED
ON DRAWINGS
SUITE 050
SUITE 080
02 03 0401
A
WOMEN'S RM
MEN'S RM
A1
A1 A1 A1
EXISTING CELIING.
EXISTING MEDALLION FROM
ABOVE NEWEL POST.EXISTING SLOPED CEILINGENTRYWAY ENTABULATURE ANDMOLDING, TO CEILING
EX. PIPES
EXISTING
STRUCTURAL
POST TO CEILING
ENTRYWAY ENTABULATURE ANDMOLDING, TO CEILING
TO CORNUCOPIA
TO HERRELL'S ABOVE STAIRS UP TO LANDINGNEW STRUCTURAL POSTS TO EXISTING STRUCTURE ABOVE TIN
CEILING, TYP @ EACH MULLION AT ALL NEW STOREFRONT WALLS.
EXISTING DROPPED
BOX BEAM TO REMAIN
ARCHITECT/OWNER/CONTRACTOR TO
REVIEW IN FIELD FRAMING CONDITIONS
AT EXISTING WOOD COLUMN SURROUND TO FINALIZE FRAMING.
EXISTING BEAM.
EX. PIPES
1
A-12
1
A-10
1
A-11
A1
A1 A1 A1
PROPOSED RCP - LEVEL L1
3/16" = 1'-0"1
VERIFY ALL DIMENSIONS IN THE FIELD
NOTES:
1. PATCH/REPAIR/REPLACE AREAS OF TIN
CEILING AFFECTED BY DEMO OF EXISTING STOREFRONTS AS DIRECTED
BY OWNER.
2. OWNER TO REVIEW EXISTING LIGHTING AT NEW RAMP CORRIDOR TO DETERMINE IF NEW FIXTURES WILL BE
INSTALLED. PENDANT FIXTURES
INDICATED ARE FOR RECOMMENDED
LOCATIONS ONLY.
3. OWNER TO COORDINATE ALL
REMOVAL/RELOCATION OF EXISTING LIGHT FIXTURES AND FINAL LOCATION
OF DUPLEX OUTLETS.
4. OWNER TO COORDINATE REMOVAL/RELOCATION OF ALL EXISTING UTILITIES IN THE AREA OF NEW ENTRY &
STOREFRONTS.
DATE: 1/9/17
196 Pleasant St.
Northampton
MA 01060
413-585-0641
REGISTERED ARCHITECT, COMMONWEALTH OF MASSACHUSETTS
This drawing is not intended nor shall it be used for con-struction purposes unless the signed professional seal of a registered architect employed by Thomas Douglas
Architects is affixed in the space below. The Architect shall be deemed the author of these documents and
shall retain all common law, statutory and other reserved rights, including the copyright.
THOMAS DOUGLAS ARCHITECTS, INC.
PERMIT SET - FOR CONSTRUCTION
BOILER ROOM
UTILITY/
STORAGE
ELEC. ROOM
WORK ROOM
STORAGE ROOM
L1 CORRIDOR
EXISTING PIPES & DUCTS
TO REMAIN, PROTECT IN
PLACE (NOT ALL ELEMENTS
SHOWN)
NEW
CEILING @ 9’2”±, GWB,
PAINTED TO
MATCH
ADJACENT
EXISTING CEILING
@ 15’0”±, TOREMAIN
EXISTING CEILING @8’4”±, TO REMAIN
EXISTING CEILING
@ 8’5 1/2”±, TO
REMAIN
EXISTINGCEILING @
8’-10” TO
REMAIN
EXISTING
CEILING TO
REMAIN
NEW PSL
STUD WALL
15'-0"
02
15'-0"
03
14'-11 1/2"
0401
OUTLINE OF NEWRAMP ABOVE
OUTLINE OFCONTRACTOR
WORK AREA
SEE NOTES
FOR PHASE II
WORK IN THISROOM
EX. DROPPED
BEAM
WORK IN THIS AREA OF THE CEILING LIMITED
TO INSTALLATION OF SOLID BLOCKING
BETWEEN JOISTS, NEW PSL POST & REPAIROF CEILING AS NECESSARY. PROVIDE
SUPPORT OF ALL EXISTING UTILITIES ASNECESSARY.
EXISTING
SLOPED
CEILING, TO
REMAIN
1
A-12
1
A-10
1
A-11
A-9PROPOSED L1 RAMP AND STOREFRONTS
PROPOSED RCP - LEVEL L2 SCALE: AS NOTED
ON DRAWINGS
VERIFY ALL DIMENSIONS IN THE FIELD
PROPOSED RCP - L2
3/16" = 1'-0"1
NOTES:
1. PHASE 1 CEILING WORKS CONSISTS
OF:
A. TEMPORARY SUPPORTING ALL
CEILING HUNG CONDUITS PIPES, WIRING, ETC. AT AREA OF DEMO & NEW
CONSTRUCTION AT UTILITY/STORAGE
ROOM & BOILER ROOM.
B. CAREFULLY SAWCUTTING, ONLY AS NECESSARY, PORTIONS OF EXISTING
CEILING IN UTILITY/STORAGE ROOM FOR INSTALLATION OF NEW PSL POSTS & TOP
PLATES.
C. RESUPPORT OF EXISTING UTILTIES
TO STRUCTURE ABOVE. NO UTILITIES SHALL BE SUPPORTED FROM CEILING WITHOUT SOLID BLOCKING ABOVE.
2. PHASE II WORK IN BOILER ROOM
CONSISTS OF:
A. PROTECT ALL UTILITIES & EQUIPMENT DURING DEMO & CONSTRUCTION.
B. CAREFULLY SAWCUT & REMOVE ALL
TIN CEILINGS, METAL LATH & PLASTER.
C. RESUPPORT OF EXISTING UTILIES TO STRUCTURE ABOVE OR EXISTING
SUPERSTRUCTURE. NO UTILITIES SHALL BE SUPPORTED FROM CEILING WITHIN
SOLID BLOCKING ABOVE.
D. INSTALL NEW 5/8" GWB CEILING SHALL BE ATTACHED TO UNDERSIDE OF EXISTING CEILING JOISTS, TAPED &
COMPLETELY FIRE SEALED AT
PERIMETER & FIRE CAULKED AT ALL PIPE
PENETRATIONS.
E. ALL EXISTING WALL PENETRATIONS
SHALL BE SEALED WITH FIRE RATED CAULKING.
DATE: 1/9/17
196 Pleasant St.
Northampton
MA 01060
413-585-0641
REGISTERED ARCHITECT, COMMONWEALTH OF MASSACHUSETTS
This drawing is not intended nor shall it be used for con-struction purposes unless the signed professional seal of a registered architect employed by Thomas Douglas
Architects is affixed in the space below. The Architect shall be deemed the author of these documents and
shall retain all common law, statutory and other reserved rights, including the copyright.
THOMAS DOUGLAS ARCHITECTS, INC.
PERMIT SET - FOR CONSTRUCTION
A-10PROPOSED L1 RAMP AND STOREFRONTS
INTERIOR ELEVATIONS SCALE: AS NOTED
ON DRAWINGS
STORAGE ROOM
EXISTING
STAIRS TO
LEVEL L1
EX. 11 1/2”x14” ± BEAM (BEYOND, EXTENDS BELOW TIN CLG)
EX. TIN CEILING ON LATH & PLASTER
11'-6 7/8"±VARIESEX. 11
1/2”x14” ± BEAM
UTILTY/STORAGE
ROOM
WORK ROOM
GWB
GWBGWBGWB INSTALL NEW FRAMING & PATCH & PAINT GWB @ AREA OF DEMO’D DOOR
EX. SOFFITTO REMAIN
NEW 2x10 RAMP STRUCTURE BUILT OVER EX. FLOOR
NEW 2x BLOCKING
BETWEEN EX. JOISTS
AT 1/3 POINTS OF NEW RAMP WIDTH, TYP.
1A-1315'-0"
02
15'-0"
03
14'-11 1/2"
0401
NEWSAFETY
FILM
(BOTH
SIDES)
1x6 BASEBOARD WITH
HALF-LAP SPLICE JOINTS, TYP.
SIM.
NEW SAFETY FILM
NEW SLIDING BARN DOOR ON S.S. TRACK
EX. HALF
WALL WITH
NEW CAP
REINSTALL
METAL RAILING
EXISTING STOREFRONT WITH NEW SAFETY FILM WHERE INDICATEDNEW STOREFRONT WITH ALL TEMPERED GLASS
NEW 2x10
STRINGERS @ 12”o.c. & 3/4” T&G PLYWOOD DECKING.
SOLID BLOCKING @ 48” o.c.
NEWSTOREFRONTENTRY
SUITE 080
PAINT EX. CASING
EXISTING EXPOSED STEAM PIPEEXISTING STEAM PIPE WITHIN NEW GWB WALL
GWB
GWB
EXISTING EXPOSED SPRINKLER PIPE
1'-5"1'-8"1'-5"1'-8"GWB WINDOW CASINGWALL TRIM
EX. BRICK WALL
NEWSAFETY
FILM
(BOTH
SIDES)
NEWSAFETY
FILM
(BOTH
SIDES)
NEWSAFETY
FILM
(BOTH
SIDES)
PROVIDE SOLID BLOCKING FOR HANDRAIL CONNECTIONS
PROVIDE
HANDRAIL
CONNECTIONS AT EACH VERTICAL MULLION
SEE SHEET A-16 FOR
NEW WORK IN THIS AREA
1'-8"5'-10"1'-10"HERRELL'S
10'-6" ±
LEVEL L1
13'-6" ±
LEVEL L2
0'-0"
3
A-16
VERIFY ALL DIMENSIONS IN THE FIELD
PROPOSED INTERIOR ELEVATION
3/16" = 1'-0"1
PAINT EX. CASING
12" MIN.
GWB
JOIST HANGER AT EACH NEW STRINGER - SIMPSON LSSU210.
(3) TRUSSLOK SCREWS @ 16”o.c.
(3) 1 3/4” x 11 7/8” LVL JOISTS SUPPORTED AT EX. BEAM AND NEW BEARING WALL OR (2) LVL JOISTS SISTERED INTO EXISTING FLOOR JOIST WITH TRUSSLOCK SCREWS AND WITH SOLID
BEARING BOTH ENDS.
DEMO PORTION OF
FINISHED FLOOR AS NECESSARY FOR INSTALLATION OF SOLID WOOD TRANSITION AT
BOTTOM OF RAMP.
EXISTING TIN, METAL LATH & PLASTER
CEILING.
NOTES:
1. RAMP DECKING SHALL BE 3/4" T&G PLYWOOD DECKING, DOC-PS1. APA RATED 24/48 APPLIED W/10d COMMON NAILS AT
6"o.c. AT ALL PANEL EDGES AND 12"o.c. AT ALL PANEL FIELDS.
CONSTRUCTION ADHESIVE AT ALL JOISTS & EDGES.
2. FINISH FLOORING SHALL BE: GERFLOR CREATION CLIC SYSTEM STYLE/COLOR: 0577 ALBION
SIZE: 8"x48.8" VINYL PLANKS RUN PLANKS PERPENDICULAR TO
RAMP RUN.
DATE: 1/9/17
196 Pleasant St.
Northampton MA 01060413-585-0641
REGISTERED ARCHITECT, COMMONWEALTH OF MASSACHUSETTS
This drawing is not intended nor shall it be used for con-struction purposes unless the signed professional seal of a registered architect employed by Thomas Douglas Architects is affixed in the space below. The Architect shall be deemed the author of these documents and shall retain all common law, statutory and other reserved rights, including the copyright.
THOMAS DOUGLAS ARCHITECTS, INC.
PERMIT SET - FOR CONSTRUCTION
A-11PROPOSED L1 RAMP AND STOREFRONTS
INTERIOR ELEVATIONS SCALE: AS NOTED
ON DRAWINGS
VERIFY ALL DIMENSIONS IN THE FIELD
OPEN
EXISTING STOREFRONT WITH NEW SAFETY FILM AS INDICATED NEW STOREFRONT WITH ALL TEMPERED GLASS
EX. FLOOR
1 3/4” FLOORING
2X14± JOISTS
11'-6 7/8"±VARIESUTILTY/STORAGE ROOMFRP TO 8'-0"GWBGWB
NEW SAFETYFILM
1x6 BASEBOARD WITH HALF-LAP SPLICE JOINTS, TYP.
NEW 3 1/2” x 3 1/2” PSL STUD WALL. FINISH WITH 3/4” T&G
PLYWOOD AND FRP.
NEW DOUBLE TOP PLATE TO SUPPORT EX. JOISTS
EX. HALF WALL WITH
NEW CAP
WORK ROOMSTORAGE ROOM 1'-8"5'-10"1'-10"NEWSTOREFRONTENTRY SUITE050
OPENOPENOPENOPENOPENOPENOPEN
NEW SAFETYFILM
NEW SAFETYFILMNEW SAFETYFILMNEW SAFETYFILM
NEW SAFETYFILM
NEW SAFETYFILM
NEW SAFETYFILM EX. TEMEPERED
GLAZING
WINDOW CASING WALL TRIM GWB
GWB GWBGWB
EXISTING PIPING
NEW SUPPORT POSTS TO
EXISTING
STRUCTURE ABOVE TIN CEILING. REPAIR TIN CEILING AS DIRECTED
BY OWNER.
PROVIDEHANDRAILCONNECTORSAT EACH
VERTICAL
MULLION.1'-5"1'-8"1
A-13
EX. DUCTTO REMAIN,PROTECTIN PLACE
NEW 2x BLOCKINGBETWEEN EX. JOISTSAT 1/3 POINTS OF NEWRAMP WIDTH, TYP.
NEW 2x10 RAMP
STRUCTURE BUILT
OVER EX. FLOOR
3 1/2” x 3 1/2” PSLPOST (BEYOND)
GWB
GWB
SIMPSON STRONG-TIEA23 CLIP ANGLE
OPEN
HERRELL'S
10'-6" ±
LEVEL L1
13'-6" ±
LEVEL L2
0'-0"
PROPOSED INTERIOR ELEVATION
3/16" = 1'-0"1
NOTES:
1. HANDRAILS SHALL BE GALVANIZED
STEEL, PAINTED. RETURN ALL ENDS TO
WALL/COLUMN. PROVIDE SOLID
BLOCKING AT ALL WALL CONNECTIONS.
DATE: 1/9/17
196 Pleasant St.
Northampton MA 01060413-585-0641
REGISTERED ARCHITECT, COMMONWEALTH OF MASSACHUSETTS
This drawing is not intended nor shall it be used for con-struction purposes unless the signed professional seal of a registered architect employed by Thomas Douglas Architects is affixed in the space below. The Architect shall be deemed the author of these documents and shall retain all common law, statutory and other reserved rights, including the copyright.
THOMAS DOUGLAS ARCHITECTS, INC.
PERMIT SET - FOR CONSTRUCTION
A-12PROPOSED L1 RAMP AND STOREFRONTS
INTERIOR ELEVATIONS SCALE: AS NOTED
ON DRAWINGS2'-10"1'-6"3'-4"EX. RISER (BEYOND)
BEAM WRAPTO REMAIN
EXISTING WOOD STAIRS EX. RAMP TO SUITE 040
EXISTING TINCEILING TO REMAIN
HALLWAY TO
NEW RAMP &
HERRELL'S
TO
RAMPNEWENTRYSUITE 080
NEWENTRYSUITE 050 1'-8"5'-10"1'-10"EXISTING STOREFRONT TO REMAINNEW STOREFRONT WITH ALL TEMPERED GLASS NEW STOREFRONT WITH ALL TEMPERED GLASS
1x6 BASEBOARD WITH
HALF-LAP SPLICE JOINTS.
WINDOW CASINGWALL TRIM
EX. NEWEL POSTBASE @ CLG
A
PROPOSED INTERIOR ELEVATION
3/16" = 1'-0"1
PROPOSED SECTION: ENLARGED DETAIL
3/16" = 1'-0"2
UTIL.
SINKS
BOILER ROOM
HALLWAY (RAMP)
TOWARDS
HERRELL'S
COL. 2
FACE OF EX. 11 1/2” x 14” ±BEAM (SUPPORTS LOWER
LEVEL OF RAMP)
UTILITY/STORAGE ROOM
EX. 1 1/2” PLASTER FINISH IN
BOILER ROOM TO REMAIN,
PATCH & REPAIR AS NEEDED
NEW 3 1/2” x 3 1/2” PSL STUDS IN BEARING WALL TO SUPPORT NEW DOUBLE PLATE & EX. 2x14 JOISTS. HORIZONTAL
BLOCKING @ 1/3 POINTS.
EX. 2x14 JOISTS
NEW 2x10STRINGERS
SUPPORTING
NEW RAMP
NEW DOUBLE 2x4 PLATE AT TOP
OF NEW PSL WALL DIRECTLY
SUPPORTING EX. 2x14 JOISTS
EX. MTL STUDS TO REMAIN.
EX. PIPE RISER TO REMAIN.PROTECT IN PLACE.
NEW STUD WALL &
GWB/STOREFRONT TOENCLOSE RISER
OPEN TOWORK
ROOM
EX. 2x14 JOISTS
NEW 3/4” PLYWOOD WITH FRP IN UTIL./STORAGE ROOM. SOLID
BLOCKING @ ALL HORIZONTAL
JOINTS IN SHEATHING.
A
NEW 2x4 P.T. SOLE PLATE
BOLTED INTO CONCRETE SLAB 11'-6 7/8" ±V.I.F.1
A-13
3
A-12
HERRELL'S
10'-6" ±
LEVEL L1
13'-6" ±
LEVEL L2
0'-0"
VERIFY ALL DIMENSIONS IN THE FIELD
NEW 2x10
STRINGERS
SUPPORTING
NEW RAMP
EX. 111/2” x16” ±
BEAM
2X BLOCKING TO
SUPPORT EX.
FLOORING
EX. VERTICAL STEAM PIPE
NEW 5/4x12 LEDGER
ATTACHED TO SIDE OF EX. BEAM
NEW 2x6 PARTITION WALL AT EX. PIPE.
EX.WOOD
COLUMN
EX. VERTICAL PIPE
DETAIL: RAMP AT EXISTING BEAM
3/4" = 1'-0"3
4 3/4"2"TENANTRAMP
3/4” PLYWOOD CONTINUOUS FROM JOIST ENDS DOWN TO BOTTOM OF NEW PRESSURE TREATED SOLE PLATE.1'-8"BOILER ROOM
UTILITY/WORK ROOM 1'-10"5'-10"EXISTING 1 1/2” PLASTER TO REMAINNEW FRP OVER 3/4” PLYWOODSHEATHING, NAILED TO EACH
NEW STUD AT 12”o.c. AND TO
END OF EACH JOIST AND
BLOCKING AT 6”o.c.
CUT HOLES IN EXISTING DROP
TIN CEILING ASSEMBLY FOR
NEW PSL STUDS. KEEPPENETRATION SIZES TO AMINIMUM. SUPPORT REMAININGCEILING.
EXISTING SUBFLOOR AND FINISH FLOOR TO
REMAIN. CUT BACK EX. FINISH FLOOR FOR
INSTALLATION OF DOUBLE SOLE PLATE.
EXISTING 3-5/8” METAL STUD WALL & TOP PLATE TO REMAIN IN PLACE.
1x6
1x6
1x41x4
1x41x4
4 3/4"
INSTALL NEW 3 1/2” x 31/2” PSL STUDS BENEATH EACH EXISTING JOIST TO BE CUT. ADD CONTINUOUS DOUBLE TOP PLATE AND PRESSURE TREATED SOLE PLATE.2"1x41x4
4 3/4"2"1x41x42"1x41x4
2"3/4"JAMBS, MULLIONS, SILLS, AND STOPS
WITH
OVOLO
PROFILE.
TEMPERED
SAFETY GLAZING
JAMBS & MULLION PLAN VIEW
VARIESEXISTING TIN/MTL LATH & PLASTER CLG.
INSTALL SOLID 2x BLOCKING BETWEEN ALL FLOOR JOISTS @ NEW BEARING WALL.
EXISTING 2x14 JOISTS
STRINGER LEDGERED TO NEW
3/4” PLYWOOD ON BEARING
WALL, WITH SOLID BLOCKING.
NEW 3/4” T&GPLYWOOD ON 2x10STRINGERS.
HEAD, PAINTED
POPLAR
CASING
OVERLAPS
WINDOW FRAME
BY 3/4”. TYP.
SILL, PAINTED
POPLAR
NEOPRENEGASKET, TYP.
1x4 TRIM, TYP.
PROPOSED STOREFRONT WALL SECTION
1 1/2" = 1'-0"4
DATE: 1/9/17
196 Pleasant St.
Northampton MA 01060413-585-0641
REGISTERED ARCHITECT, COMMONWEALTH OF MASSACHUSETTS
This drawing is not intended nor shall it be used for con-struction purposes unless the signed professional seal of a registered architect employed by Thomas Douglas Architects is affixed in the space below. The Architect shall be deemed the author of these documents and shall retain all common law, statutory and other reserved rights, including the copyright.
THOMAS DOUGLAS ARCHITECTS, INC.
PERMIT SET - FOR CONSTRUCTION
4"2"1'-10"4"2"3/4"TENANTRAMP
4"2"1/2” HARDWOOD PLYWOOD WITH
MITERED EDGES OVER
2x STRUCTURE,
PAINTED: 1 PRIME COAT, 2 TOP COATS.
GWB SIGN
BAND
4
3
OPENTOBEYOND+/- 3'-0 3/4"ENTABLATURE7'-6"OPENINGELEV.
10'-6 3/4" ±
SECURITY CURTAIN POCKET BEHIND PANEL
DOOR WITH CONCEALED
HAFELE HINGES &
SILENCERS.
1/2” HARDWOOD PLYWOOD
WITH MITERED EDGES
OVER 2x STRUCTURE, PAINTED: 1 PRIME COAT, 2 TOP COATS AT ENTIRE STOREFRONT ENTRY.
SIGN BAND
CURTAIN TRACK &
CANVAS SECURITY CURTAIN
CORRIDORTENANT
CONTINUOUS CROWN MOULDING, PROFILE CB4220.
CONTINUOUS CROWN
MOULDING, PROFILE CB4236.
1x PAINT GRADE POPLAR
1/2” GWB AT BOTH SIDES OF ENTABLATURE
2x6 BOX BEAM
2x CRIPPLE STUDS AT 16”o.c.
2x4 CROSSBRACING ATTACHEDTO EACH CRIPPLE
STUD AND
TOE-NAILED TO BOX
BEAM.
1x6 POPLAR BASE WITH 1x3 BASE SHOE
1/2” HARDWOOD PLYWOOD
5'-9"1'-6 1/2"1 1/2"5 1/2"11"1 1/2"
11 1/2"
5 1/2"
1 1/2"
2X3BLOCKING
PANELDOOR
PROPOSED STOREFRONT ENTRY OUTSIDE ELEVATION
1/2" = 1'-0"1
A-13PROPOSED L1 RAMP AND STOREFRONTS
DETAILS SCALE: AS NOTED
ON DRAWINGS
VERIFY ALL DIMENSIONS IN THE FIELDPROPOSED STOREFRONT ENTRY SECTION
3/4" = 1'-0"3PROPOSED STOREFRONT ENTRY PLAN
3/4" = 1'-0"2
3"
3 1/2"
5 1/2"
3 1/2"
3"
1 1/2"11"5 1/2"1 1/2"
1 1/2"1'-6"
1/2” HARDWOOD PLYWOOD,
KERFED ON THE INSIDE FACE AND CURVED.
2X4 FRAMING
2X6 JACK STUD AND KING
STUD. KING STUD SHALL
BE ATTACHED TO EX. STRUCTURE ABOVE CEILING.
2X6 FRAMING WALL. ADJUST AS NECESARY AT WOOD COLUMN ENCLOSURE AT SUITE 080.
2X6 FRAMING WALL
2X FINS AT 16”o.c. VERTICALLY
DATE: 1/9/17
196 Pleasant St.
Northampton MA 01060413-585-0641
REGISTERED ARCHITECT, COMMONWEALTH OF MASSACHUSETTS
This drawing is not intended nor shall it be used for con-struction purposes unless the signed professional seal of a registered architect employed by Thomas Douglas Architects is affixed in the space below. The Architect shall be deemed the author of these documents and shall retain all common law, statutory and other reserved rights, including the copyright.
THOMAS DOUGLAS ARCHITECTS, INC.
PERMIT SET - FOR CONSTRUCTION
A-14PROPOSED L1 RAMP AND STOREFRONTS
FRAMING PLAN - LEVEL L1 SCALE: AS NOTED
ON DRAWINGS
UP
DN
SUITE 050
SUITE 080
EXISTING HISTORICSTAIRS
UP
EXISTINGRAMP02 03 0401
UPDN
WOMEN'S RM
MEN'S RMNEW 3 1/2” x 3 1/2” PSL POST DIRECTLY BELOW NEW LVL HEADER.
EXISTING2x14±JOISTS
NEW 2x10 STRINGERS
@ 12”o.c. AT RAMP.
3/4” PLYWOOD RIM JOIST @ END
OF EX. JOISTS.
NEW 2x4 DOUBLE TOP PLATE & P.T. SOLE
PLATE AT BEARING WALL, SUPPORTING EX.
2x14± JOISTS.
NEW (2) 1-3/4” x 11-7/8” LVL BELOW JOIST ENDS (ABOVE WORK ROOM) WITH 8”
MINIMUM BEARING ON BRICK WALL AND
3-1/2” x 3-1/2” PSL POST (BELOW). ATTACH TO
PSL POST WITH SIMPSON EPCZ POST CAP.
ARCHITECT TO REVIEW EXISTING FRAMING
CONDITIONS DURING DEMO.
EXISTING
2x14±
JOISTS
(2) 1 3/4” X 11 7/8” LVL
HEADER. PROVIDE
SOLID BLOCKING
BEHIND.
SOLID BLOCKING, TYP.
NEW KNEE WALL
SUPPORTS ON EX. FLOOR, WITH SOLID
BLOCKING BETWEEN
JOISTS.
NEW 2x10 FLOORJOISTS @ 12”o.c. BEAR
ON EXISTING BEAM &
NEW STUD WALL.
TO HERRELL’S
1
A-12
1
A-10
1
A-11
PROPOSED PLAN - LEVEL L1
3/16" = 1'-0"1
VERIFY ALL DIMENSIONS IN THE FIELD
DATE: 1/9/17
196 Pleasant St.
Northampton MA 01060413-585-0641
REGISTERED ARCHITECT, COMMONWEALTH OF MASSACHUSETTS
This drawing is not intended nor shall it be used for con-struction purposes unless the signed professional seal of a registered architect employed by Thomas Douglas Architects is affixed in the space below. The Architect shall be deemed the author of these documents and shall retain all common law, statutory and other reserved rights, including the copyright.
THOMAS DOUGLAS ARCHITECTS, INC.
PERMIT SET - FOR CONSTRUCTION
A-15PROPOSED L1 RAMP AND STOREFRONTS
EXISTING CONDITIONS AT BOTTOM OF RAMP SCALE: AS NOTED
ON DRAWINGS
VERIFY ALL DIMENSIONS IN THE FIELD1'-4 1/2"7'-0"EXISTING BEAM,
JOISTS, FLOOR
SYSTEM TO REMAIN
DEMO EXISTING CURVED
PLEXIGLAS
SKYLIGHTS & WOOD FRAME
DEMO EXISTING
RAILING/ WALL
CAP. REMOVE & REINSTALL METAL RAILING.
DEMO EXISTING DOORFRAME & LOWERWINDOW. UPPERWINDOW & FRAME TOREMAIN.
EXISTING WINDOWS & FRAMES TO REMAIN.
EXISTINGCOVE &
LIGHTING
TO
REMAIN
EXISTING HALF WALL &
STAIRS TO REMAIN
A
EXISTING ELEVATION - SLIDING DOOR
3/16" = 1'-0"1
CAREFULLY REMOVE ALL WALL MOUNTED PIPES, CONDUITS, SHELVING & EQUIPMENT, STORE FOR REINSTALLATION. DEMO GWB, ON THIS SIDE OF WALL ONLY, STUDS TO REMAIN. ALL PIPES
THAT PENETRATE WALL TO REMAIN IN PLACE.
EX. HALF WALL @ STAIR
DEMO
PLEXIGLAS
WINDOW &
WOOD CAP
DEMO DOOR
FRAME, LOWER WINDOW & FRAME
STORAGE ROOM
04
EXISTING
STAIRS TO
LEVEL L1
1'-0"
EXISTING ELEVATION - SLIDING DOOR
3/16" = 1'-0"2
DN
03
14'-11 1/2"
04
MEN'S RM
A1 A1 TO HERRELL'S
3
A-16
1
A-16
2
A-16
1
A-15
2
A-15
KEY TO SLIDING DOOR DRAWINGS
3/16" = 1'-0"
DATE: 1/9/17
196 Pleasant St.
Northampton MA 01060413-585-0641
REGISTERED ARCHITECT, COMMONWEALTH OF MASSACHUSETTS
This drawing is not intended nor shall it be used for con-struction purposes unless the signed professional seal of a registered architect employed by Thomas Douglas Architects is affixed in the space below. The Architect shall be deemed the author of these documents and shall retain all common law, statutory and other reserved rights, including the copyright.
THOMAS DOUGLAS ARCHITECTS, INC.
PERMIT SET - FOR CONSTRUCTION
A-16PROPOSED L1 RAMP AND STOREFRONTS
NEW BARN DOOR AT BOTTOM OF RAMP SCALE: AS NOTED
ON DRAWINGS
VERIFY ALL DIMENSIONS IN THE FIELD
PROPOSED SLIDING DOOR AT FORMER SKYLIGHT
EXISTINGWINDOWS &FRAMES TOREMAIN.
EXISTINGWINDOW &FRAME TOREMAIN.
EX. HALF WALL
WITH NEW CAP. REINSTALL METAL RAILING.
NEW SLIDING DOOR ON BARN DOOR HARDWARE TRACK
NEW 1x6 TRIM BAND AT HARDWARE TRACK, REPLACES EX. 2” TRIM
BENEATH SILL
STORAGE ROOM
A
EXISTINGWINDOWS &FRAMES TOREMAIN.
EXISTINGWINDOW &FRAME TOREMAIN.
NEW SLOPED
SURFACE
BETWEEN CAP
& SLIDING DOOR. 3/4” HARDWOOD PLYWOOD
OVER 2x8
JOISTS.
NEW SLIDING DOOR
ON BARN DOOR
HARDWARE TRACK
NEW GWB CEILING OVER
2x12 JOISTS.
FINISH FLOOR
TO MATCH EXISTING.9'-4 1/4"4 1/2"8'-0"STORAGE ROOM
A
PROPOSED ELEVATION - SLIDING DOOR WITH STAIR & HALF WALL
3/16" = 1'-0"1 NEW SLIDING DOOR WITH NEW SLOPED SURFACE
3/16" = 1'-0"2 NEW SLIDING DOOR
3/16" = 1'-0"3
EXISTING EXPOSED SPRINKLER PIPE
SLIDING BARN DOOR HARDWARE
DATE: 1/9/17
196 Pleasant St.
Northampton MA 01060413-585-0641
REGISTERED ARCHITECT, COMMONWEALTH OF MASSACHUSETTS
This drawing is not intended nor shall it be used for con-struction purposes unless the signed professional seal of a registered architect employed by Thomas Douglas Architects is affixed in the space below. The Architect shall be deemed the author of these documents and shall retain all common law, statutory and other reserved rights, including the copyright.
THOMAS DOUGLAS ARCHITECTS, INC.
PERMIT SET - FOR CONSTRUCTION
A-17PROPOSED L1 RAMP AND STOREFRONTS
DETAILS SCALE: AS NOTED
ON DRAWINGS
VERIFY ALL DIMENSIONS IN THE FIELD
EX. WOOD
COLUMN
EX.
STOREFRONT
02
A
UPPER RAMP2x10 STUD WALL WITH(1) LAYER 5/8” GWB
EACH SIDE
NEW METAL RAILING
HOLD FRAMING MIN. 2”OFF FACE OF STEAM
PIPE.
EX. STEAM PIPE
RAMP LANDING
EDGE OF RAMP
NEW
HANDRAILS
EXISTING
STOREFRONT
SOLID MULLION
AS NECESSARY
5/8” GWB OVER 2x4 FRAMING
NEW TEMPERED
STOREFRONT WINDOW
NEW 2x4 KNEE WALL WITH CAP TO MATCH
ADJACENT EX. KNEE
WALL
WALL FRAMING DETAIL @ SUITE 080
1" = 1'-0"1 WALL FRAMING DETAIL @ SUITE 050
1" = 1'-0"2
DATE: 1/9/17
196 Pleasant St.
Northampton
MA 01060
413-585-0641
REGISTERED ARCHITECT, COMMONWEALTH OF MASSACHUSETTS
This drawing is not intended nor shall it be used for con-struction purposes unless the signed professional seal of a registered architect employed by Thomas Douglas
Architects is affixed in the space below. The Architect shall be deemed the author of these documents and
shall retain all common law, statutory and other reserved rights, including the copyright.
THOMAS DOUGLAS ARCHITECTS, INC.
PERMIT SET - FOR CONSTRUCTION