Loading...
2017-01-25 L1 Ramp & Storefronts - STAMPEDA-1PROPOSED L1 RAMP AND STOREFRONTS DEMO PLAN - LEVEL L1 SCALE: AS NOTED ON DRAWINGS VERIFY ALL DIMENSIONS IN THE FIELD L1 ELEV. 0'-0" L1 ELEV. 0'-0" DEMO PORTION OF WALL AS NECESSARY FOR INSTALLATION OF NEW WINDOW FLOORING & CEILING IN THIS AREA TO BE REVIEWED AFTER WALL DEMO, FOR EXTENT OF REPAIR/REPLACEMENT EXISTING PIPING TO REMAIN OUTLINE OF CONTRACTOR WORK AREA EXISTING TIMBER COLUMNS TO REMAIN OUTLINE OFCONTRACTOR WORK AREA NO WORK IN THIS AREA NO WORK IN THIS AREA HERRELL'S ELEV. -3'-0" STE. 050 LOWER ELEV. -1'-6" STE. 080 UPPER ELEV. 2'-6" L1 ELEV. 0'-0" UP DN DN SUITE 050 SUITE 080 5'-3 1/2"16'-4 3/4"11"4 3/4"6'-9 3/4"1'-1 1/4"5'-9"DEMO FLOOR ATBOTTOM OF RAMP -SEE A-10 FLOORING & CEILING IN THIS AREA TO BE REVIEWED AFTER WALL DEMO, FOR EXTENT OF REPAIR/REPLACEMENT EXISTING HISTORICSTAIRS 6"EXISTING COLUMN SURROUND TO REMAIN DEMO EXISTING BUILT-IN COUNTERS DEMO PORTIONOF EXISTING HALF WALL 1'-0" UP EXISTINGRAMP15'-0" 02 15'-0" 03 14'-11 1/2" 0401 UPTHIS WALL TO BEDEMO’ED DURINGBATHROOM PROJECT 41'-0" NEW RAMP OUTLINE DN WOMEN'S RM MEN'S RM4"5'-2"1 A-3 1 A-4 1 A-5 DEMO PLAN - LEVEL L1 3/16" = 1'-0"1 NOTES: 1. DEMO EXISTING WALL, DOORS, STAIRS AS NOTED WITHIN WORK AREA.2. PROTECT ADJACENT FINISHES, WINDOWS, COLUMNS, PIPING, ETC. TO REMAIN DURING CONSTRUCTION. DATE: 1/9/17 EX. PIPING AT ENTRYWAYS EX. PIPING AT HALL PERMIT SET - FOR CONSTRUCTION 196 Pleasant St. Northampton MA 01060 413-585-0641 REGISTERED ARCHITECT, COMMONWEALTH OF MASSACHUSETTS This drawing is not intended nor shall it be used for con-struction purposes unless the signed professional seal of a registered architect employed by Thomas Douglas Architects is affixed in the space below. The Architect shall be deemed the author of these documents and shall retain all common law, statutory and other reserved rights, including the copyright. THOMAS DOUGLAS ARCHITECTS, INC. A-2PROPOSED L1 RAMP AND STOREFRONTS DEMO PLAN - LEVEL L2 SCALE: AS NOTED ON DRAWINGS VERIFY ALL DIMENSIONS IN THE FIELD UP UP SHELF SHELF3'-0" X 8'-0" WORK TABLE 3'-0" X 7'-0"WORK TABLETABLEUP 8'-0"BOILER ROOM UTILITY/ STORAGE ELEC. ROOM WORK ROOM 6'-8" X 2'-4 1/2" UTILITY SINKS6'-0 1/2"STORAGE ROOM L1 CORRIDOR UP UP3'-6 1/2"12'-1 1/2"28'-10 1/2" RAMP OUTLINE ABOVE EXISTING MASONRYWALL & COLUMNS RELOCATE EX.SHELF DURINGCONTRUCTION EXISTING MASONRY WALL EX. BEAM ABOVE RAMP OUTLINE ABOVE OUTLINE OFCONTRACTORWORK AREA OUTLINE OF CONTRACTOR WORK AREA NO WORK ON BOILER ROOM PLASTER WALL IN THIS CONTRACT. EXISTING METAL STUD, GWB, & PLASTER WALL. DEMO GWB TO METAL STUDS @ UTIL./STORAGE ROOM. REMOVE SINK,SHELVES, & ALL PIPING IN THIS AREA. STORE FOR REINSTALLATION. 15'-0" 02 15'-0" 03 14'-11 1/2" 01 04 OUTLINE OFCONTRACTOR WORK AREA 2'-1"2'-1" SAWCUT & REMOVE PORTION OF CONCRETE SLAB FOR INSTALLATION OF NEW PIER FOOTING DEMO PORTION OF WALL & CEILING IN THIS AREA. SEE SHEETS A-15 & A-16. 1 A-3 1 A-4 1 A-5 DEMO PLAN - LEVEL L2 (FLOOR DIRECTLY BELOW PROPOSED RAMP) 3/16" = 1'-0"1 DATE: 1/9/17 196 Pleasant St. Northampton MA 01060 413-585-0641 REGISTERED ARCHITECT, COMMONWEALTH OF MASSACHUSETTS This drawing is not intended nor shall it be used for con-struction purposes unless the signed professional seal of a registered architect employed by Thomas Douglas Architects is affixed in the space below. The Architect shall be deemed the author of these documents and shall retain all common law, statutory and other reserved rights, including the copyright. THOMAS DOUGLAS ARCHITECTS, INC. PERMIT SET - FOR CONSTRUCTION A-3PROPOSED L1 RAMP AND STOREFRONTS DEMO SECTIONS/ELEVATIONS SCALE: AS NOTED ON DRAWINGS VERIFY ALL DIMENSIONS IN THE FIELD EX. 11 1/2”x14” ± BEAM (PROJECTS BELOW TIN CLG)12'-2"±EX. TIN CEILING ON MTL LATH, PLASTER & WOOD FURRING 11'-9"±VARIESEX. 11 1/2”x14” ± BEAM (BEYOND) EX. STAIRS TO BE REMOVED10'-7"EX. PIPE TO REMAIN, PROTECT IN PLACE UTILTY/STORAGE ROOM CAREFULLY REMOVE ALL WALL MOUNTED PIPES, CONDUITS, SHELVING & EQUIPMENT, STORE FOR REINSTALLATION. DEMO GWB, ON THIS SIDE OF WALL ONLY, STUDS TO REMAIN. ALL PIPES THAT PENETRATE WALL TO REMAIN IN PLACE. DEMO EX. DOOR & CASING. EX. WINDOW & CASING TO REMAIN. PROTECT DURING CONSTRUCTION. EX. HALF WALL @ STAIR DEMO PLEXIGLAS WINDOW & WOOD CAP DEMO DOOR FRAME, LOWER WINDOW & FRAME EX. GWB OVER MTLSTUDS EX. BRICK WALL DEMO EX. WINDOW,CASING & WALLAS INDICATED EX. BRICK PIER, TYP WORK ROOM STORAGE ROOM EX. PIPING TO REMAIN. PROTECT IN PLACE. EXISTINGOPENING TOBEYOND SUITE 080 EX. WINDOW & CASING TO REMAIN. PROTECT DURING CONSTRUCTION.TYP. EXISTING STAIRS TO LEVEL L1 DEMO EX. BRICK AS NECESSARY TO ACCOMMODATE NEW RAMP STRINGERS 02 03 0401 DEMO EX. FLOORING &2X14± JOISTS IN THE AREA OF NEW RAMP AS INDICATED EXISTING STAIRS TOLEVEL L1 1'-0" EXISTING STOREFRONT TO REMAIN STOREFRONT TO BE DEMOLISHED EXISTING STOREFRONT TO REMAIN HERRELL'S 10'-6" ± LEVEL L1 13'-6" ± LEVEL L2 0'-0" EXISTING LONGITUDINAL SECTION 3/16" = 1'-0"1 DATE: 1/9/17 196 Pleasant St. Northampton MA 01060 413-585-0641 REGISTERED ARCHITECT, COMMONWEALTH OF MASSACHUSETTS This drawing is not intended nor shall it be used for con-struction purposes unless the signed professional seal of a registered architect employed by Thomas Douglas Architects is affixed in the space below. The Architect shall be deemed the author of these documents and shall retain all common law, statutory and other reserved rights, including the copyright. THOMAS DOUGLAS ARCHITECTS, INC. PERMIT SET - FOR CONSTRUCTION A-4PROPOSED L1 RAMP AND STOREFRONTS DEMO SECTIONS/ELEVATIONS SCALE: AS NOTED ON DRAWINGS VERIFY ALL DIMENSIONS IN THE FIELD EXISTING TEMPERED GLASS EX. STAIRS TO BE REMOVED EX. DUCT TO REMAIN, PROTECT IN PLACE ±10'-7"UTILTY/STORAGE ROOM EX. UTIL. SINKS SHELVES CAREFULLY REMOVE ALL WALL MOUNTED PIPES, CONDUITS, SHELVING & EQUIPMENT, STORE FOR REINSTALLATION. DEMO GWB, ON THIS SIDE OF WALL ONLY, STUDS TO REMAIN. ALL PIPES THAT PENETRATE WALL TO REMAIN IN PLACE. PAPERTOWELSDISP. SHELVES REMOVE SECTIONS OF EX. TIN & PLYWOOD CEILING AS NECESSARY FOR INSTALLATION OF NEW BLOCKING EXISTING STOREFRONT TO REMAIN STOREFRONT TO BE DEMOLISHED EXISTING OPENING TO BEYONDSUITE 050DEMO EX. FLOORING 2X14± JOISTS AS INDICATEDAT AREA OFRAMP ALL EXISTING UTILITIES @ CEILING TO REMAIN OPERATIONAL DURING DEMO & CONSTRUCTION. PROVIDE TEMPORARY SUPPORT AS NECESSARY FOR INSTALLATION & BLOCKING. WORK ROOM CORRIDORSTORAGE ROOM EX. BRICK WALL EX. TIN CEILING, HEIGHT VARIES. EX. STOREFRONT WALL SUPPORT POST DEMO EX. STOREFRONT WALL SUPPORT POST DEMO PORTIONS OF EXISTING CLG ONLY AS NECESSARY TO ATTACH NEW SUPPORT POSTS TO EX. FRAMING ABOVE.EX. DROPPED BEAM.EX. PLUMBING OR SPRINKLER LINES EX. 2x14 FLOOR JOISTS. EX. GWB WALL TO CORNUCOPIATO HERRELL’S HERRELL'S 10'-6" ± LEVEL L1 13'-6" ± LEVEL L2 0'-0" DEMO SECTION 3/16" = 1'-0"2 DATE: 1/9/17 196 Pleasant St. Northampton MA 01060 413-585-0641 REGISTERED ARCHITECT, COMMONWEALTH OF MASSACHUSETTS This drawing is not intended nor shall it be used for con-struction purposes unless the signed professional seal of a registered architect employed by Thomas Douglas Architects is affixed in the space below. The Architect shall be deemed the author of these documents and shall retain all common law, statutory and other reserved rights, including the copyright. THOMAS DOUGLAS ARCHITECTS, INC. PERMIT SET - FOR CONSTRUCTION A-5PROPOSED L1 RAMP AND STOREFRONTS DEMO SECTIONS/ELEVATIONS SCALE: AS NOTED ON DRAWINGS VERIFY ALL DIMENSIONS IN THE FIELD BOILER ROOM EX. 11 1/2” x 14” ± BEAM (SUPPORTS FLOOR JOISTS@ LOWER LEVEL OF RAMP) EX. 11 1/2” x 16” ± BEAM COL. 2 EX. STEAM PIPE RISER TO REMAIN. PROTECT IN PLACE. UTILTY/STORAGE ROOM REMOVE PORTION OF EX. FLOOR FOR NEW RAMP EXISTING STOREFRONT WALLS TO BE DEMO’ED. DEMO EXISTING CURVED PLEXIGLAS SKYLIGHTS & WOOD FRAME DEMO EXISTING RAILING/ WALL CAP. REMOVE & REINSTALL METAL RAILING. EXISTING WINDOWS & FRAMES TO REMAIN. EXISTING HALF WALL & STAIRS TO REMAIN UTIL.SINKS SUITE 080 HALLWAY (RAMP)SUITE 050 SAWCUT &REMOVE PORTION OF FLOOR JOISTS FLOOR JOISTS TO REMAIN EX. FLOOR JOISTS TO REMAIN. SHALL BERESUPPORTED BY NEW BEARING WALL BELOW. DEMO EX. GWB, METAL STUDS TO REMAIN. SAWCUT EX. TIN CEILING IN UTLITY/STORAGE ROOM ONLY AS NECESSARY FOR INSTALLATION OF NEW PSL POSTS. DEMO PORTION OF EX. GWB WALL ASNECESSARY FOR CONSTRUCTION OF NEWLOAD-BEARING WALL. EXISTING OPENING TO BEYOND A HERRELL'S 10'-6" ± LEVEL L1 13'-6" ± LEVEL L2 0'-0" DEMO SECTION 3/16" = 1'-0"3 DATE: 1/9/17 196 Pleasant St. Northampton MA 01060 413-585-0641 REGISTERED ARCHITECT, COMMONWEALTH OF MASSACHUSETTS This drawing is not intended nor shall it be used for con-struction purposes unless the signed professional seal of a registered architect employed by Thomas Douglas Architects is affixed in the space below. The Architect shall be deemed the author of these documents and shall retain all common law, statutory and other reserved rights, including the copyright. THOMAS DOUGLAS ARCHITECTS, INC. PERMIT SET - FOR CONSTRUCTION A-6PROPOSED L1 RAMP AND STOREFRONTS PROPOSED PLAN - LEVEL L1 SCALE: AS NOTED ON DRAWINGS UP UP DN SUITE 050 SUITE 080 EXISTING STAIRS EXISTING HISTORICSTAIRS 2'-0 1/8" UP EXISTINGRAMP15'-0" 02 15'-0" 03 14'-11 1/2" 0401 UPDN WOMEN'S RM MEN'S RM A RAMP OUTLINE DNDN 15'-0" HORIZONTAL 1'-0" MIN. 21'-0" HORIZONTAL5'-0" LEVEL LANDING RAMP 1:12 MAX. 1 A-6TYP.EX. STOREFRONT GLAZING WITH NEW SAFETY FILM @ SELECT LOCATIONS. SEE ELEVATIONS. EX. STOREFRONT GLAZING WITH NEW SAFETY FILM EX. STOREFRONT GLAZING NEW STOREFRONT GLAZING 3'-0" NEW STOREFRONT GLAZING NEW STORE F R O N T NEW STEEL HANDRAILS BOLTED INTO WALL & WALL COLUMNS. PROVIDE SOLID BLOCKING BEHIND ALL CONNECTIONS.±5'-0"(44" MIN. REQ.)NEW CUSTOM WOOD SLIDING DOOR - WHITE OAK & TEMPERED GLAZING. EX. WOOD COLUMN SURROUND TO REMAIN. PROTECT IN PLACE. RAMP 1:12 MAX. NEW HALF WALL SEGMENT, MATCH EXISTING FINISH.40.00°4"5'-0"NEW STOREFRONT GLAZING3'-10"3'-9"3'-9"3'-9"3'-10" 3'-10"3'-9"3'-10"2'-6"2'-6"3'-9"3'-9"NEW STOREFRONTGLAZING40.00 ° TO CORNUCOPIA TO HERRELL'S GLAZIN G 1 A-12 1 A-10 1 A-11 1A-17 2 A-17 PROPOSED PLAN - LEVEL L1 3/16" = 1'-0"1 VERIFY ALL DIMENSIONS IN THE FIELD DATE: 1/9/17 196 Pleasant St. Northampton MA 01060 413-585-0641 REGISTERED ARCHITECT, COMMONWEALTH OF MASSACHUSETTS This drawing is not intended nor shall it be used for con-struction purposes unless the signed professional seal of a registered architect employed by Thomas Douglas Architects is affixed in the space below. The Architect shall be deemed the author of these documents and shall retain all common law, statutory and other reserved rights, including the copyright. THOMAS DOUGLAS ARCHITECTS, INC. PERMIT SET - FOR CONSTRUCTION SHELF SHELF3'-0" X 8'-0" WORK TABLE 3'-0" X 7'-0"WORK TABLETABLE8'-0"BOILER ROOM UTILITY/ STORAGE ELEC. ROOM WORK ROOM 6'-8" X 2'-4 1/2" UTILITY SINKS6'-0 1/2"STORAGE ROOM L1 CORRIDOR UP UP3'-6 1/2"12'-1 1/2"28'-10 1/2" INSTALL NEW FRAMING AT DEMO’ED SKYLIGHT OPENINGS & PATCH & PAINT GWB @ AREA OF DEMO’EDSKYLIGHT INSTALL TEMPORARY SUPPORTS FOR TIN CEILING ASSEMBLY IN BOILER ROOM. NEW 3 1/2”x3 1/2” PSL STUDS BELOW EACH EX. JOIST END, WITH 3/4” PLYWOOD SHEATHING & FRP IN UTIL./STORAGE ROOM. SEE NOTE 1. EX. METAL STUDS & PLASTER IN BOILER ROOM TO REMAIN. 15'-0" 02 15'-0" 03 14'-11 1/2" 0401 OUTLINE OF RAMP ABOVE. NEW 3-1/2” x 3-1/2” PSL POST ON SIMPSON PB44 POST BASE EMBEDDED IN NEW 24”x24”x8” CONCRETE PIER 2'-1"2'-1" A 1 A-12 1 A-10 1A-11 A-7PROPOSED L1 RAMP AND STOREFRONTS PROPOSED PLAN - LEVEL L2 SCALE: AS NOTED ON DRAWINGS VERIFY ALL DIMENSIONS IN THE FIELD PROPOSED PLAN - LEVEL L2 (FLOOR DIRECTLY BELOW PROPOSED RAMP) 3/16" = 1'-0"1 DATE: 1/9/17 196 Pleasant St. Northampton MA 01060 413-585-0641 REGISTERED ARCHITECT, COMMONWEALTH OF MASSACHUSETTS This drawing is not intended nor shall it be used for con-struction purposes unless the signed professional seal of a registered architect employed by Thomas Douglas Architects is affixed in the space below. The Architect shall be deemed the author of these documents and shall retain all common law, statutory and other reserved rights, including the copyright. THOMAS DOUGLAS ARCHITECTS, INC. PERMIT SET - FOR CONSTRUCTION A-8PROPOSED L1 RAMP AND STOREFRONTS PROPOSED RCP - LEVEL L1 SCALE: AS NOTED ON DRAWINGS SUITE 050 SUITE 080 02 03 0401 A WOMEN'S RM MEN'S RM A1 A1 A1 A1 EXISTING CELIING. EXISTING MEDALLION FROM ABOVE NEWEL POST.EXISTING SLOPED CEILINGENTRYWAY ENTABULATURE ANDMOLDING, TO CEILING EX. PIPES EXISTING STRUCTURAL POST TO CEILING ENTRYWAY ENTABULATURE ANDMOLDING, TO CEILING TO CORNUCOPIA TO HERRELL'S ABOVE STAIRS UP TO LANDINGNEW STRUCTURAL POSTS TO EXISTING STRUCTURE ABOVE TIN CEILING, TYP @ EACH MULLION AT ALL NEW STOREFRONT WALLS. EXISTING DROPPED BOX BEAM TO REMAIN ARCHITECT/OWNER/CONTRACTOR TO REVIEW IN FIELD FRAMING CONDITIONS AT EXISTING WOOD COLUMN SURROUND TO FINALIZE FRAMING. EXISTING BEAM. EX. PIPES 1 A-12 1 A-10 1 A-11 A1 A1 A1 A1 PROPOSED RCP - LEVEL L1 3/16" = 1'-0"1 VERIFY ALL DIMENSIONS IN THE FIELD NOTES: 1. PATCH/REPAIR/REPLACE AREAS OF TIN CEILING AFFECTED BY DEMO OF EXISTING STOREFRONTS AS DIRECTED BY OWNER. 2. OWNER TO REVIEW EXISTING LIGHTING AT NEW RAMP CORRIDOR TO DETERMINE IF NEW FIXTURES WILL BE INSTALLED. PENDANT FIXTURES INDICATED ARE FOR RECOMMENDED LOCATIONS ONLY. 3. OWNER TO COORDINATE ALL REMOVAL/RELOCATION OF EXISTING LIGHT FIXTURES AND FINAL LOCATION OF DUPLEX OUTLETS. 4. OWNER TO COORDINATE REMOVAL/RELOCATION OF ALL EXISTING UTILITIES IN THE AREA OF NEW ENTRY & STOREFRONTS. DATE: 1/9/17 196 Pleasant St. Northampton MA 01060 413-585-0641 REGISTERED ARCHITECT, COMMONWEALTH OF MASSACHUSETTS This drawing is not intended nor shall it be used for con-struction purposes unless the signed professional seal of a registered architect employed by Thomas Douglas Architects is affixed in the space below. The Architect shall be deemed the author of these documents and shall retain all common law, statutory and other reserved rights, including the copyright. THOMAS DOUGLAS ARCHITECTS, INC. PERMIT SET - FOR CONSTRUCTION BOILER ROOM UTILITY/ STORAGE ELEC. ROOM WORK ROOM STORAGE ROOM L1 CORRIDOR EXISTING PIPES & DUCTS TO REMAIN, PROTECT IN PLACE (NOT ALL ELEMENTS SHOWN) NEW CEILING @ 9’2”±, GWB, PAINTED TO MATCH ADJACENT EXISTING CEILING @ 15’0”±, TOREMAIN EXISTING CEILING @8’4”±, TO REMAIN EXISTING CEILING @ 8’5 1/2”±, TO REMAIN EXISTINGCEILING @ 8’-10” TO REMAIN EXISTING CEILING TO REMAIN NEW PSL STUD WALL 15'-0" 02 15'-0" 03 14'-11 1/2" 0401 OUTLINE OF NEWRAMP ABOVE OUTLINE OFCONTRACTOR WORK AREA SEE NOTES FOR PHASE II WORK IN THISROOM EX. DROPPED BEAM WORK IN THIS AREA OF THE CEILING LIMITED TO INSTALLATION OF SOLID BLOCKING BETWEEN JOISTS, NEW PSL POST & REPAIROF CEILING AS NECESSARY. PROVIDE SUPPORT OF ALL EXISTING UTILITIES ASNECESSARY. EXISTING SLOPED CEILING, TO REMAIN 1 A-12 1 A-10 1 A-11 A-9PROPOSED L1 RAMP AND STOREFRONTS PROPOSED RCP - LEVEL L2 SCALE: AS NOTED ON DRAWINGS VERIFY ALL DIMENSIONS IN THE FIELD PROPOSED RCP - L2 3/16" = 1'-0"1 NOTES: 1. PHASE 1 CEILING WORKS CONSISTS OF: A. TEMPORARY SUPPORTING ALL CEILING HUNG CONDUITS PIPES, WIRING, ETC. AT AREA OF DEMO & NEW CONSTRUCTION AT UTILITY/STORAGE ROOM & BOILER ROOM. B. CAREFULLY SAWCUTTING, ONLY AS NECESSARY, PORTIONS OF EXISTING CEILING IN UTILITY/STORAGE ROOM FOR INSTALLATION OF NEW PSL POSTS & TOP PLATES. C. RESUPPORT OF EXISTING UTILTIES TO STRUCTURE ABOVE. NO UTILITIES SHALL BE SUPPORTED FROM CEILING WITHOUT SOLID BLOCKING ABOVE. 2. PHASE II WORK IN BOILER ROOM CONSISTS OF: A. PROTECT ALL UTILITIES & EQUIPMENT DURING DEMO & CONSTRUCTION. B. CAREFULLY SAWCUT & REMOVE ALL TIN CEILINGS, METAL LATH & PLASTER. C. RESUPPORT OF EXISTING UTILIES TO STRUCTURE ABOVE OR EXISTING SUPERSTRUCTURE. NO UTILITIES SHALL BE SUPPORTED FROM CEILING WITHIN SOLID BLOCKING ABOVE. D. INSTALL NEW 5/8" GWB CEILING SHALL BE ATTACHED TO UNDERSIDE OF EXISTING CEILING JOISTS, TAPED & COMPLETELY FIRE SEALED AT PERIMETER & FIRE CAULKED AT ALL PIPE PENETRATIONS. E. ALL EXISTING WALL PENETRATIONS SHALL BE SEALED WITH FIRE RATED CAULKING. DATE: 1/9/17 196 Pleasant St. Northampton MA 01060 413-585-0641 REGISTERED ARCHITECT, COMMONWEALTH OF MASSACHUSETTS This drawing is not intended nor shall it be used for con-struction purposes unless the signed professional seal of a registered architect employed by Thomas Douglas Architects is affixed in the space below. The Architect shall be deemed the author of these documents and shall retain all common law, statutory and other reserved rights, including the copyright. THOMAS DOUGLAS ARCHITECTS, INC. PERMIT SET - FOR CONSTRUCTION A-10PROPOSED L1 RAMP AND STOREFRONTS INTERIOR ELEVATIONS SCALE: AS NOTED ON DRAWINGS STORAGE ROOM EXISTING STAIRS TO LEVEL L1 EX. 11 1/2”x14” ± BEAM (BEYOND, EXTENDS BELOW TIN CLG) EX. TIN CEILING ON LATH & PLASTER 11'-6 7/8"±VARIESEX. 11 1/2”x14” ± BEAM UTILTY/STORAGE ROOM WORK ROOM GWB GWBGWBGWB INSTALL NEW FRAMING & PATCH & PAINT GWB @ AREA OF DEMO’D DOOR EX. SOFFITTO REMAIN NEW 2x10 RAMP STRUCTURE BUILT OVER EX. FLOOR NEW 2x BLOCKING BETWEEN EX. JOISTS AT 1/3 POINTS OF NEW RAMP WIDTH, TYP. 1A-1315'-0" 02 15'-0" 03 14'-11 1/2" 0401 NEWSAFETY FILM (BOTH SIDES) 1x6 BASEBOARD WITH HALF-LAP SPLICE JOINTS, TYP. SIM. NEW SAFETY FILM NEW SLIDING BARN DOOR ON S.S. TRACK EX. HALF WALL WITH NEW CAP REINSTALL METAL RAILING EXISTING STOREFRONT WITH NEW SAFETY FILM WHERE INDICATEDNEW STOREFRONT WITH ALL TEMPERED GLASS NEW 2x10 STRINGERS @ 12”o.c. & 3/4” T&G PLYWOOD DECKING. SOLID BLOCKING @ 48” o.c. NEWSTOREFRONTENTRY SUITE 080 PAINT EX. CASING EXISTING EXPOSED STEAM PIPEEXISTING STEAM PIPE WITHIN NEW GWB WALL GWB GWB EXISTING EXPOSED SPRINKLER PIPE 1'-5"1'-8"1'-5"1'-8"GWB WINDOW CASINGWALL TRIM EX. BRICK WALL NEWSAFETY FILM (BOTH SIDES) NEWSAFETY FILM (BOTH SIDES) NEWSAFETY FILM (BOTH SIDES) PROVIDE SOLID BLOCKING FOR HANDRAIL CONNECTIONS PROVIDE HANDRAIL CONNECTIONS AT EACH VERTICAL MULLION SEE SHEET A-16 FOR NEW WORK IN THIS AREA 1'-8"5'-10"1'-10"HERRELL'S 10'-6" ± LEVEL L1 13'-6" ± LEVEL L2 0'-0" 3 A-16 VERIFY ALL DIMENSIONS IN THE FIELD PROPOSED INTERIOR ELEVATION 3/16" = 1'-0"1 PAINT EX. CASING 12" MIN. GWB JOIST HANGER AT EACH NEW STRINGER - SIMPSON LSSU210. (3) TRUSSLOK SCREWS @ 16”o.c. (3) 1 3/4” x 11 7/8” LVL JOISTS SUPPORTED AT EX. BEAM AND NEW BEARING WALL OR (2) LVL JOISTS SISTERED INTO EXISTING FLOOR JOIST WITH TRUSSLOCK SCREWS AND WITH SOLID BEARING BOTH ENDS. DEMO PORTION OF FINISHED FLOOR AS NECESSARY FOR INSTALLATION OF SOLID WOOD TRANSITION AT BOTTOM OF RAMP. EXISTING TIN, METAL LATH & PLASTER CEILING. NOTES: 1. RAMP DECKING SHALL BE 3/4" T&G PLYWOOD DECKING, DOC-PS1. APA RATED 24/48 APPLIED W/10d COMMON NAILS AT 6"o.c. AT ALL PANEL EDGES AND 12"o.c. AT ALL PANEL FIELDS. CONSTRUCTION ADHESIVE AT ALL JOISTS & EDGES. 2. FINISH FLOORING SHALL BE: GERFLOR CREATION CLIC SYSTEM STYLE/COLOR: 0577 ALBION SIZE: 8"x48.8" VINYL PLANKS RUN PLANKS PERPENDICULAR TO RAMP RUN. DATE: 1/9/17 196 Pleasant St. Northampton MA 01060413-585-0641 REGISTERED ARCHITECT, COMMONWEALTH OF MASSACHUSETTS This drawing is not intended nor shall it be used for con-struction purposes unless the signed professional seal of a registered architect employed by Thomas Douglas Architects is affixed in the space below. The Architect shall be deemed the author of these documents and shall retain all common law, statutory and other reserved rights, including the copyright. THOMAS DOUGLAS ARCHITECTS, INC. PERMIT SET - FOR CONSTRUCTION A-11PROPOSED L1 RAMP AND STOREFRONTS INTERIOR ELEVATIONS SCALE: AS NOTED ON DRAWINGS VERIFY ALL DIMENSIONS IN THE FIELD OPEN EXISTING STOREFRONT WITH NEW SAFETY FILM AS INDICATED NEW STOREFRONT WITH ALL TEMPERED GLASS EX. FLOOR 1 3/4” FLOORING 2X14± JOISTS 11'-6 7/8"±VARIESUTILTY/STORAGE ROOMFRP TO 8'-0"GWBGWB NEW SAFETYFILM 1x6 BASEBOARD WITH HALF-LAP SPLICE JOINTS, TYP. NEW 3 1/2” x 3 1/2” PSL STUD WALL. FINISH WITH 3/4” T&G PLYWOOD AND FRP. NEW DOUBLE TOP PLATE TO SUPPORT EX. JOISTS EX. HALF WALL WITH NEW CAP WORK ROOMSTORAGE ROOM 1'-8"5'-10"1'-10"NEWSTOREFRONTENTRY SUITE050 OPENOPENOPENOPENOPENOPENOPEN NEW SAFETYFILM NEW SAFETYFILMNEW SAFETYFILMNEW SAFETYFILM NEW SAFETYFILM NEW SAFETYFILM NEW SAFETYFILM EX. TEMEPERED GLAZING WINDOW CASING WALL TRIM GWB GWB GWBGWB EXISTING PIPING NEW SUPPORT POSTS TO EXISTING STRUCTURE ABOVE TIN CEILING. REPAIR TIN CEILING AS DIRECTED BY OWNER. PROVIDEHANDRAILCONNECTORSAT EACH VERTICAL MULLION.1'-5"1'-8"1 A-13 EX. DUCTTO REMAIN,PROTECTIN PLACE NEW 2x BLOCKINGBETWEEN EX. JOISTSAT 1/3 POINTS OF NEWRAMP WIDTH, TYP. NEW 2x10 RAMP STRUCTURE BUILT OVER EX. FLOOR 3 1/2” x 3 1/2” PSLPOST (BEYOND) GWB GWB SIMPSON STRONG-TIEA23 CLIP ANGLE OPEN HERRELL'S 10'-6" ± LEVEL L1 13'-6" ± LEVEL L2 0'-0" PROPOSED INTERIOR ELEVATION 3/16" = 1'-0"1 NOTES: 1. HANDRAILS SHALL BE GALVANIZED STEEL, PAINTED. RETURN ALL ENDS TO WALL/COLUMN. PROVIDE SOLID BLOCKING AT ALL WALL CONNECTIONS. DATE: 1/9/17 196 Pleasant St. Northampton MA 01060413-585-0641 REGISTERED ARCHITECT, COMMONWEALTH OF MASSACHUSETTS This drawing is not intended nor shall it be used for con-struction purposes unless the signed professional seal of a registered architect employed by Thomas Douglas Architects is affixed in the space below. The Architect shall be deemed the author of these documents and shall retain all common law, statutory and other reserved rights, including the copyright. THOMAS DOUGLAS ARCHITECTS, INC. PERMIT SET - FOR CONSTRUCTION A-12PROPOSED L1 RAMP AND STOREFRONTS INTERIOR ELEVATIONS SCALE: AS NOTED ON DRAWINGS2'-10"1'-6"3'-4"EX. RISER (BEYOND) BEAM WRAPTO REMAIN EXISTING WOOD STAIRS EX. RAMP TO SUITE 040 EXISTING TINCEILING TO REMAIN HALLWAY TO NEW RAMP & HERRELL'S TO RAMPNEWENTRYSUITE 080 NEWENTRYSUITE 050 1'-8"5'-10"1'-10"EXISTING STOREFRONT TO REMAINNEW STOREFRONT WITH ALL TEMPERED GLASS NEW STOREFRONT WITH ALL TEMPERED GLASS 1x6 BASEBOARD WITH HALF-LAP SPLICE JOINTS. WINDOW CASINGWALL TRIM EX. NEWEL POSTBASE @ CLG A PROPOSED INTERIOR ELEVATION 3/16" = 1'-0"1 PROPOSED SECTION: ENLARGED DETAIL 3/16" = 1'-0"2 UTIL. SINKS BOILER ROOM HALLWAY (RAMP) TOWARDS HERRELL'S COL. 2 FACE OF EX. 11 1/2” x 14” ±BEAM (SUPPORTS LOWER LEVEL OF RAMP) UTILITY/STORAGE ROOM EX. 1 1/2” PLASTER FINISH IN BOILER ROOM TO REMAIN, PATCH & REPAIR AS NEEDED NEW 3 1/2” x 3 1/2” PSL STUDS IN BEARING WALL TO SUPPORT NEW DOUBLE PLATE & EX. 2x14 JOISTS. HORIZONTAL BLOCKING @ 1/3 POINTS. EX. 2x14 JOISTS NEW 2x10STRINGERS SUPPORTING NEW RAMP NEW DOUBLE 2x4 PLATE AT TOP OF NEW PSL WALL DIRECTLY SUPPORTING EX. 2x14 JOISTS EX. MTL STUDS TO REMAIN. EX. PIPE RISER TO REMAIN.PROTECT IN PLACE. NEW STUD WALL & GWB/STOREFRONT TOENCLOSE RISER OPEN TOWORK ROOM EX. 2x14 JOISTS NEW 3/4” PLYWOOD WITH FRP IN UTIL./STORAGE ROOM. SOLID BLOCKING @ ALL HORIZONTAL JOINTS IN SHEATHING. A NEW 2x4 P.T. SOLE PLATE BOLTED INTO CONCRETE SLAB 11'-6 7/8" ±V.I.F.1 A-13 3 A-12 HERRELL'S 10'-6" ± LEVEL L1 13'-6" ± LEVEL L2 0'-0" VERIFY ALL DIMENSIONS IN THE FIELD NEW 2x10 STRINGERS SUPPORTING NEW RAMP EX. 111/2” x16” ± BEAM 2X BLOCKING TO SUPPORT EX. FLOORING EX. VERTICAL STEAM PIPE NEW 5/4x12 LEDGER ATTACHED TO SIDE OF EX. BEAM NEW 2x6 PARTITION WALL AT EX. PIPE. EX.WOOD COLUMN EX. VERTICAL PIPE DETAIL: RAMP AT EXISTING BEAM 3/4" = 1'-0"3 4 3/4"2"TENANTRAMP 3/4” PLYWOOD CONTINUOUS FROM JOIST ENDS DOWN TO BOTTOM OF NEW PRESSURE TREATED SOLE PLATE.1'-8"BOILER ROOM UTILITY/WORK ROOM 1'-10"5'-10"EXISTING 1 1/2” PLASTER TO REMAINNEW FRP OVER 3/4” PLYWOODSHEATHING, NAILED TO EACH NEW STUD AT 12”o.c. AND TO END OF EACH JOIST AND BLOCKING AT 6”o.c. CUT HOLES IN EXISTING DROP TIN CEILING ASSEMBLY FOR NEW PSL STUDS. KEEPPENETRATION SIZES TO AMINIMUM. SUPPORT REMAININGCEILING. EXISTING SUBFLOOR AND FINISH FLOOR TO REMAIN. CUT BACK EX. FINISH FLOOR FOR INSTALLATION OF DOUBLE SOLE PLATE. EXISTING 3-5/8” METAL STUD WALL & TOP PLATE TO REMAIN IN PLACE. 1x6 1x6 1x41x4 1x41x4 4 3/4" INSTALL NEW 3 1/2” x 31/2” PSL STUDS BENEATH EACH EXISTING JOIST TO BE CUT. ADD CONTINUOUS DOUBLE TOP PLATE AND PRESSURE TREATED SOLE PLATE.2"1x41x4 4 3/4"2"1x41x42"1x41x4 2"3/4"JAMBS, MULLIONS, SILLS, AND STOPS WITH OVOLO PROFILE. TEMPERED SAFETY GLAZING JAMBS & MULLION PLAN VIEW VARIESEXISTING TIN/MTL LATH & PLASTER CLG. INSTALL SOLID 2x BLOCKING BETWEEN ALL FLOOR JOISTS @ NEW BEARING WALL. EXISTING 2x14 JOISTS STRINGER LEDGERED TO NEW 3/4” PLYWOOD ON BEARING WALL, WITH SOLID BLOCKING. NEW 3/4” T&GPLYWOOD ON 2x10STRINGERS. HEAD, PAINTED POPLAR CASING OVERLAPS WINDOW FRAME BY 3/4”. TYP. SILL, PAINTED POPLAR NEOPRENEGASKET, TYP. 1x4 TRIM, TYP. PROPOSED STOREFRONT WALL SECTION 1 1/2" = 1'-0"4 DATE: 1/9/17 196 Pleasant St. Northampton MA 01060413-585-0641 REGISTERED ARCHITECT, COMMONWEALTH OF MASSACHUSETTS This drawing is not intended nor shall it be used for con-struction purposes unless the signed professional seal of a registered architect employed by Thomas Douglas Architects is affixed in the space below. The Architect shall be deemed the author of these documents and shall retain all common law, statutory and other reserved rights, including the copyright. THOMAS DOUGLAS ARCHITECTS, INC. PERMIT SET - FOR CONSTRUCTION 4"2"1'-10"4"2"3/4"TENANTRAMP 4"2"1/2” HARDWOOD PLYWOOD WITH MITERED EDGES OVER 2x STRUCTURE, PAINTED: 1 PRIME COAT, 2 TOP COATS. GWB SIGN BAND 4 3 OPENTOBEYOND+/- 3'-0 3/4"ENTABLATURE7'-6"OPENINGELEV. 10'-6 3/4" ± SECURITY CURTAIN POCKET BEHIND PANEL DOOR WITH CONCEALED HAFELE HINGES & SILENCERS. 1/2” HARDWOOD PLYWOOD WITH MITERED EDGES OVER 2x STRUCTURE, PAINTED: 1 PRIME COAT, 2 TOP COATS AT ENTIRE STOREFRONT ENTRY. SIGN BAND CURTAIN TRACK & CANVAS SECURITY CURTAIN CORRIDORTENANT CONTINUOUS CROWN MOULDING, PROFILE CB4220. CONTINUOUS CROWN MOULDING, PROFILE CB4236. 1x PAINT GRADE POPLAR 1/2” GWB AT BOTH SIDES OF ENTABLATURE 2x6 BOX BEAM 2x CRIPPLE STUDS AT 16”o.c. 2x4 CROSSBRACING ATTACHEDTO EACH CRIPPLE STUD AND TOE-NAILED TO BOX BEAM. 1x6 POPLAR BASE WITH 1x3 BASE SHOE 1/2” HARDWOOD PLYWOOD 5'-9"1'-6 1/2"1 1/2"5 1/2"11"1 1/2" 11 1/2" 5 1/2" 1 1/2" 2X3BLOCKING PANELDOOR PROPOSED STOREFRONT ENTRY OUTSIDE ELEVATION 1/2" = 1'-0"1 A-13PROPOSED L1 RAMP AND STOREFRONTS DETAILS SCALE: AS NOTED ON DRAWINGS VERIFY ALL DIMENSIONS IN THE FIELDPROPOSED STOREFRONT ENTRY SECTION 3/4" = 1'-0"3PROPOSED STOREFRONT ENTRY PLAN 3/4" = 1'-0"2 3" 3 1/2" 5 1/2" 3 1/2" 3" 1 1/2"11"5 1/2"1 1/2" 1 1/2"1'-6" 1/2” HARDWOOD PLYWOOD, KERFED ON THE INSIDE FACE AND CURVED. 2X4 FRAMING 2X6 JACK STUD AND KING STUD. KING STUD SHALL BE ATTACHED TO EX. STRUCTURE ABOVE CEILING. 2X6 FRAMING WALL. ADJUST AS NECESARY AT WOOD COLUMN ENCLOSURE AT SUITE 080. 2X6 FRAMING WALL 2X FINS AT 16”o.c. VERTICALLY DATE: 1/9/17 196 Pleasant St. Northampton MA 01060413-585-0641 REGISTERED ARCHITECT, COMMONWEALTH OF MASSACHUSETTS This drawing is not intended nor shall it be used for con-struction purposes unless the signed professional seal of a registered architect employed by Thomas Douglas Architects is affixed in the space below. The Architect shall be deemed the author of these documents and shall retain all common law, statutory and other reserved rights, including the copyright. THOMAS DOUGLAS ARCHITECTS, INC. PERMIT SET - FOR CONSTRUCTION A-14PROPOSED L1 RAMP AND STOREFRONTS FRAMING PLAN - LEVEL L1 SCALE: AS NOTED ON DRAWINGS UP DN SUITE 050 SUITE 080 EXISTING HISTORICSTAIRS UP EXISTINGRAMP02 03 0401 UPDN WOMEN'S RM MEN'S RMNEW 3 1/2” x 3 1/2” PSL POST DIRECTLY BELOW NEW LVL HEADER. EXISTING2x14±JOISTS NEW 2x10 STRINGERS @ 12”o.c. AT RAMP. 3/4” PLYWOOD RIM JOIST @ END OF EX. JOISTS. NEW 2x4 DOUBLE TOP PLATE & P.T. SOLE PLATE AT BEARING WALL, SUPPORTING EX. 2x14± JOISTS. NEW (2) 1-3/4” x 11-7/8” LVL BELOW JOIST ENDS (ABOVE WORK ROOM) WITH 8” MINIMUM BEARING ON BRICK WALL AND 3-1/2” x 3-1/2” PSL POST (BELOW). ATTACH TO PSL POST WITH SIMPSON EPCZ POST CAP. ARCHITECT TO REVIEW EXISTING FRAMING CONDITIONS DURING DEMO. EXISTING 2x14± JOISTS (2) 1 3/4” X 11 7/8” LVL HEADER. PROVIDE SOLID BLOCKING BEHIND. SOLID BLOCKING, TYP. NEW KNEE WALL SUPPORTS ON EX. FLOOR, WITH SOLID BLOCKING BETWEEN JOISTS. NEW 2x10 FLOORJOISTS @ 12”o.c. BEAR ON EXISTING BEAM & NEW STUD WALL. TO HERRELL’S 1 A-12 1 A-10 1 A-11 PROPOSED PLAN - LEVEL L1 3/16" = 1'-0"1 VERIFY ALL DIMENSIONS IN THE FIELD DATE: 1/9/17 196 Pleasant St. Northampton MA 01060413-585-0641 REGISTERED ARCHITECT, COMMONWEALTH OF MASSACHUSETTS This drawing is not intended nor shall it be used for con-struction purposes unless the signed professional seal of a registered architect employed by Thomas Douglas Architects is affixed in the space below. The Architect shall be deemed the author of these documents and shall retain all common law, statutory and other reserved rights, including the copyright. THOMAS DOUGLAS ARCHITECTS, INC. PERMIT SET - FOR CONSTRUCTION A-15PROPOSED L1 RAMP AND STOREFRONTS EXISTING CONDITIONS AT BOTTOM OF RAMP SCALE: AS NOTED ON DRAWINGS VERIFY ALL DIMENSIONS IN THE FIELD1'-4 1/2"7'-0"EXISTING BEAM, JOISTS, FLOOR SYSTEM TO REMAIN DEMO EXISTING CURVED PLEXIGLAS SKYLIGHTS & WOOD FRAME DEMO EXISTING RAILING/ WALL CAP. REMOVE & REINSTALL METAL RAILING. DEMO EXISTING DOORFRAME & LOWERWINDOW. UPPERWINDOW & FRAME TOREMAIN. EXISTING WINDOWS & FRAMES TO REMAIN. EXISTINGCOVE & LIGHTING TO REMAIN EXISTING HALF WALL & STAIRS TO REMAIN A EXISTING ELEVATION - SLIDING DOOR 3/16" = 1'-0"1 CAREFULLY REMOVE ALL WALL MOUNTED PIPES, CONDUITS, SHELVING & EQUIPMENT, STORE FOR REINSTALLATION. DEMO GWB, ON THIS SIDE OF WALL ONLY, STUDS TO REMAIN. ALL PIPES THAT PENETRATE WALL TO REMAIN IN PLACE. EX. HALF WALL @ STAIR DEMO PLEXIGLAS WINDOW & WOOD CAP DEMO DOOR FRAME, LOWER WINDOW & FRAME STORAGE ROOM 04 EXISTING STAIRS TO LEVEL L1 1'-0" EXISTING ELEVATION - SLIDING DOOR 3/16" = 1'-0"2 DN 03 14'-11 1/2" 04 MEN'S RM A1 A1 TO HERRELL'S 3 A-16 1 A-16 2 A-16 1 A-15 2 A-15 KEY TO SLIDING DOOR DRAWINGS 3/16" = 1'-0" DATE: 1/9/17 196 Pleasant St. Northampton MA 01060413-585-0641 REGISTERED ARCHITECT, COMMONWEALTH OF MASSACHUSETTS This drawing is not intended nor shall it be used for con-struction purposes unless the signed professional seal of a registered architect employed by Thomas Douglas Architects is affixed in the space below. The Architect shall be deemed the author of these documents and shall retain all common law, statutory and other reserved rights, including the copyright. THOMAS DOUGLAS ARCHITECTS, INC. PERMIT SET - FOR CONSTRUCTION A-16PROPOSED L1 RAMP AND STOREFRONTS NEW BARN DOOR AT BOTTOM OF RAMP SCALE: AS NOTED ON DRAWINGS VERIFY ALL DIMENSIONS IN THE FIELD PROPOSED SLIDING DOOR AT FORMER SKYLIGHT EXISTINGWINDOWS &FRAMES TOREMAIN. EXISTINGWINDOW &FRAME TOREMAIN. EX. HALF WALL WITH NEW CAP. REINSTALL METAL RAILING. NEW SLIDING DOOR ON BARN DOOR HARDWARE TRACK NEW 1x6 TRIM BAND AT HARDWARE TRACK, REPLACES EX. 2” TRIM BENEATH SILL STORAGE ROOM A EXISTINGWINDOWS &FRAMES TOREMAIN. EXISTINGWINDOW &FRAME TOREMAIN. NEW SLOPED SURFACE BETWEEN CAP & SLIDING DOOR. 3/4” HARDWOOD PLYWOOD OVER 2x8 JOISTS. NEW SLIDING DOOR ON BARN DOOR HARDWARE TRACK NEW GWB CEILING OVER 2x12 JOISTS. FINISH FLOOR TO MATCH EXISTING.9'-4 1/4"4 1/2"8'-0"STORAGE ROOM A PROPOSED ELEVATION - SLIDING DOOR WITH STAIR & HALF WALL 3/16" = 1'-0"1 NEW SLIDING DOOR WITH NEW SLOPED SURFACE 3/16" = 1'-0"2 NEW SLIDING DOOR 3/16" = 1'-0"3 EXISTING EXPOSED SPRINKLER PIPE SLIDING BARN DOOR HARDWARE DATE: 1/9/17 196 Pleasant St. Northampton MA 01060413-585-0641 REGISTERED ARCHITECT, COMMONWEALTH OF MASSACHUSETTS This drawing is not intended nor shall it be used for con-struction purposes unless the signed professional seal of a registered architect employed by Thomas Douglas Architects is affixed in the space below. The Architect shall be deemed the author of these documents and shall retain all common law, statutory and other reserved rights, including the copyright. THOMAS DOUGLAS ARCHITECTS, INC. PERMIT SET - FOR CONSTRUCTION A-17PROPOSED L1 RAMP AND STOREFRONTS DETAILS SCALE: AS NOTED ON DRAWINGS VERIFY ALL DIMENSIONS IN THE FIELD EX. WOOD COLUMN EX. STOREFRONT 02 A UPPER RAMP2x10 STUD WALL WITH(1) LAYER 5/8” GWB EACH SIDE NEW METAL RAILING HOLD FRAMING MIN. 2”OFF FACE OF STEAM PIPE. EX. STEAM PIPE RAMP LANDING EDGE OF RAMP NEW HANDRAILS EXISTING STOREFRONT SOLID MULLION AS NECESSARY 5/8” GWB OVER 2x4 FRAMING NEW TEMPERED STOREFRONT WINDOW NEW 2x4 KNEE WALL WITH CAP TO MATCH ADJACENT EX. KNEE WALL WALL FRAMING DETAIL @ SUITE 080 1" = 1'-0"1 WALL FRAMING DETAIL @ SUITE 050 1" = 1'-0"2 DATE: 1/9/17 196 Pleasant St. Northampton MA 01060 413-585-0641 REGISTERED ARCHITECT, COMMONWEALTH OF MASSACHUSETTS This drawing is not intended nor shall it be used for con-struction purposes unless the signed professional seal of a registered architect employed by Thomas Douglas Architects is affixed in the space below. The Architect shall be deemed the author of these documents and shall retain all common law, statutory and other reserved rights, including the copyright. THOMAS DOUGLAS ARCHITECTS, INC. PERMIT SET - FOR CONSTRUCTION