Thornes Men's room CD slopeRenovations to:
THORNES
MARKETPLACE
MEN'S TOILET
ROOM
FIRST FLOOR
150 MAIN STREET,
Northampton,
Massachusetts
REGISTERED ARCHITECT,
COMMONWEALTH OF
MASSACHUSETTS
This drawing is not intended nor shall it be
used for construction purposes unless the
Signed professional seal of Emily Estes
Baillargeon is affixed in the space below. The
Architect shall be deemed the author of these
documents and shall retain all common law,
statutory and other reserved rights, including
the copyright.
Rev Date Description
Project Title
Issue Date:
Drawn By:
Checked By:
Project ID:
Drawing No.
Project North
1 02/06/15 SCHEMATIC PROGRESS
Sheet Title
Scale:
02/05/2015
EEB
JPB
2015-02
AS NOTED
FIELD VERIFY ALL DIMENSIONS2 02/24/15 REVISIONS
3 02/24/15 REVISIONS
4 03/03/15 REVISIONS
WWW.ESTESARCHITECT.COM
EMILY ESTES
ARCHITECTURE + DESIGN
5 12/23/15 REVISIONS
6 1/19/16 PERMIT SET
7 2/1/16 REVISIONS
FLOOR PLANS
A-101
STORAGE
AREA
NEW 10" WET WALL IF WALL
HUNG FIXTURES CANNOT BE
SUPPORTED BY EXISTING
WALL.
5'-6" MIN3'-6"MIN3'-0" MIN
3'-6" MINBABY CHANGING
DN
UP 5'-9"3'-8"2'-0"CORIAN
COUNTERTOP ON
METAL TUBE FRAME
5'-0"MIN±5'-0 3/8"A
1
2'-8" DRYERELECTRIC HAND
DRYER. SEE
CUTSHEET.
ADD ALT 1: RECESSED
TRASH DISPENSER AND
SURFACE MOUNTED PAPER
TOWEL DISPENSER.
CONFIRM EXISTING
CONDITION IN WALL.
FLOOR DRAIN. LOCATE
IN EASIEST TO INSTALL
LOCATION.
PARTITION WALL ONLY
ADDED IF EXISTING PIPES
CANNOT BE RELOCATED.
WALL HUNG TOILETS
12 X 12 TERRAZZO TILES
WITH COVED BASE.
RUNNING BOND
PATTERN. SEE SPEC.
AREA OF WORK.
244 SQ FT
A-3.01
A-400
A
C
BD
B
C
LOWER EXISTING DOOR
FRAME TO ELIMINATE
THRESHOLD HEIGHT
BETWEEN ROOMS.
PLYWOOD RAMP MAY
NOT BE NECESSARY.
NEW MOP SINK 16" X 20"
WALLS: NEW FRP ON M.R.
GWB
GC TO DECIDE LEAST
EXPENSIVE MEANS TO
WATERPROOF FLOOR.
REMOVE EXISTING WOOD
DOOR. INFILL TO
ACHIEVE 2 HOUR FIRE
RATING. SEE UL RATING
DETAIL IN CUTSHEET.
FLOOR PLAN
Scale: 1/2" = 1'-0"2
EXISTING ELEC PANELS
TO REMAIN
2'-5"
A-3.01
A-400
E
FLOOR DRAIN.
"STOREWALL" PANELS
ON WALL WITH 10"
SHELVING
A-3.01
A-400
F
2
AREA OF WORK: 2O SQ FT1'-5"CONFIRM SOAP
DISPENSER LOCATION.
TO FOLLOW ADA
GUIDELINES.
5
6
A-102
1'-0"1'-0" MINNEW HANDRAILS
MOP CLIPS INSTALLED
OVER SINK
DETERGENT DELIVERY
SYSTEM MOUNTED TO
WALL. SPECIFIED BY
OWNER7"TOILET PAPER DISPENSER.
PROVIDED BY OWNER.
INSTALLED BY GC. BOTTOM
15” MIN AFF, TOP 48” MAX
AFF.
1'-6"
TOILET PAPER DISPENSER.
PROVIDED BY OWNER.
INSTALLED BY GC. BOTTOM
15” MIN GAFF, TOP 48” MAX
GAFF.
LEVEL LANDING
6'-0" MINCURRENTLY 5’-4” WIDE,
NEEDS TO BE 5’-6”5'-0"4'-8 1/4"
1'-8 3/4"
1'-10 1/8"2'-6"NEW WOOD RAMP.
SLOPE 1:10 FOR FIRST 3”
OF RISE.5'-6"REMOVE EXISTING PIPES
4'-1 1/4"
0"
-6"
MOVE PARITION WALL AS
MUCH AS POSSIBLE.
EXISTING PLUMBING TO
DETERMINE LOCATION.
7
NEW HANDRAILS
2'-6"3'-0"NEW WOOD RAMP.
SLOPE 1:12 FOR
REMAINING 3” OF RISE.
S
EXIT
SMOKE
EMERGENCY
LIFE SAFETY NOTES
EXISTING SPRINKLER SYSTEM TO BE RECONFIGURED AS NECESSARY TO COMPLY WITH CODES. 1.
EMERGENCY
GFI
ELECTRICAL NOTES
GENERAL CONTRACTOR TO COORDINATE LOCATION OF THERMOSTATS
WITH HVAC SUBCONTRACTOR. DIRECT QUESTIONS TO DESIGNER.
REQUIREMENTS. GENERAL CONTRACTOR TO COORDINATE.
SMOKE DETECTORS ARE REQUIRED AS PER THE LOCAL FIRE DEPARTMENTS 2.
LIFE SAFETY LEGEND
STROBE
WALL MTD. EMERGENCY LIGHTING WITH BATTERY PACK BACK-UP.
SMOKE DETECTOR
CEILING MOUNTED, EDGE LIT LED GREEN EXIT SIGN WITH BATTERY BACK-UP.
ELECTRICAL LEGEND
S SMOKE
EXIT
WALL MOUNTED - MOTION DETECTOR
OUTLET - DUPLEX
GROUND FAULT INTERRUPTER
*** ALL LIFE SAFETY FIXTURES BY GC
1.
CEILING MOUNTED MOTION DETECTOR
FLUSH MOUNTED CEILING LIGHT
WALL SCONCE LIGHT
NOT USEDC2
C1
W1
M
M
SPRINKLE ACCORDING
TO CODE
NEW GWB CEILING
EL= 7'-3" MIN.
C1
REFLECTED CEILING PLAN
Scale: 1/2" = 1'-0"1
POSSIBLE CEILING
LOCATION FOR HVAC
MECHANCIAL
EQUIPMENT.W1C1NEW LIGHT FIXTURE
AT LOCATION OF
EXISTING. REUSE AND
RELOCATE CURRENT
FIXTURE TO MOP
CLOSET.
4
LIGHT FIXTURE
CURRENTLY IN
HALLWAY. PLACE IN
NEW LOCATION.
NEW FRAMING
SEE STRUCTURALS
6
A-102
M
C1 C1
C1
C1
CENTER OVER SINKSCENTER OVER SINKS
CENTER LIGHTS
BETWEEN PARTITIONS
CEILING MOUNTED
PARTITION BRACKETS
M C1