Loading...
Thornes Men's room CD slopeRenovations to: THORNES MARKETPLACE MEN'S TOILET ROOM FIRST FLOOR 150 MAIN STREET, Northampton, Massachusetts REGISTERED ARCHITECT, COMMONWEALTH OF MASSACHUSETTS This drawing is not intended nor shall it be used for construction purposes unless the Signed professional seal of Emily Estes Baillargeon is affixed in the space below. The Architect shall be deemed the author of these documents and shall retain all common law, statutory and other reserved rights, including the copyright. Rev Date Description Project Title Issue Date: Drawn By: Checked By: Project ID: Drawing No. Project North 1 02/06/15 SCHEMATIC PROGRESS Sheet Title Scale: 02/05/2015 EEB JPB 2015-02 AS NOTED FIELD VERIFY ALL DIMENSIONS2 02/24/15 REVISIONS 3 02/24/15 REVISIONS 4 03/03/15 REVISIONS WWW.ESTESARCHITECT.COM EMILY ESTES ARCHITECTURE + DESIGN 5 12/23/15 REVISIONS 6 1/19/16 PERMIT SET 7 2/1/16 REVISIONS FLOOR PLANS A-101 STORAGE AREA NEW 10" WET WALL IF WALL HUNG FIXTURES CANNOT BE SUPPORTED BY EXISTING WALL. 5'-6" MIN3'-6"MIN3'-0" MIN 3'-6" MINBABY CHANGING DN UP 5'-9"3'-8"2'-0"CORIAN COUNTERTOP ON METAL TUBE FRAME 5'-0"MIN±5'-0 3/8"A 1 2'-8" DRYERELECTRIC HAND DRYER. SEE CUTSHEET. ADD ALT 1: RECESSED TRASH DISPENSER AND SURFACE MOUNTED PAPER TOWEL DISPENSER. CONFIRM EXISTING CONDITION IN WALL. FLOOR DRAIN. LOCATE IN EASIEST TO INSTALL LOCATION. PARTITION WALL ONLY ADDED IF EXISTING PIPES CANNOT BE RELOCATED. WALL HUNG TOILETS 12 X 12 TERRAZZO TILES WITH COVED BASE. RUNNING BOND PATTERN. SEE SPEC. AREA OF WORK. 244 SQ FT A-3.01 A-400 A C BD B C LOWER EXISTING DOOR FRAME TO ELIMINATE THRESHOLD HEIGHT BETWEEN ROOMS. PLYWOOD RAMP MAY NOT BE NECESSARY. NEW MOP SINK 16" X 20" WALLS: NEW FRP ON M.R. GWB GC TO DECIDE LEAST EXPENSIVE MEANS TO WATERPROOF FLOOR. REMOVE EXISTING WOOD DOOR. INFILL TO ACHIEVE 2 HOUR FIRE RATING. SEE UL RATING DETAIL IN CUTSHEET. FLOOR PLAN Scale: 1/2" = 1'-0"2 EXISTING ELEC PANELS TO REMAIN 2'-5" A-3.01 A-400 E FLOOR DRAIN. "STOREWALL" PANELS ON WALL WITH 10" SHELVING A-3.01 A-400 F 2 AREA OF WORK: 2O SQ FT1'-5"CONFIRM SOAP DISPENSER LOCATION. TO FOLLOW ADA GUIDELINES. 5 6 A-102 1'-0"1'-0" MINNEW HANDRAILS MOP CLIPS INSTALLED OVER SINK DETERGENT DELIVERY SYSTEM MOUNTED TO WALL. SPECIFIED BY OWNER7"TOILET PAPER DISPENSER. PROVIDED BY OWNER. INSTALLED BY GC. BOTTOM 15” MIN AFF, TOP 48” MAX AFF. 1'-6" TOILET PAPER DISPENSER. PROVIDED BY OWNER. INSTALLED BY GC. BOTTOM 15” MIN GAFF, TOP 48” MAX GAFF. LEVEL LANDING 6'-0" MINCURRENTLY 5’-4” WIDE, NEEDS TO BE 5’-6”5'-0"4'-8 1/4" 1'-8 3/4" 1'-10 1/8"2'-6"NEW WOOD RAMP. SLOPE 1:10 FOR FIRST 3” OF RISE.5'-6"REMOVE EXISTING PIPES 4'-1 1/4" 0" -6" MOVE PARITION WALL AS MUCH AS POSSIBLE. EXISTING PLUMBING TO DETERMINE LOCATION. 7 NEW HANDRAILS 2'-6"3'-0"NEW WOOD RAMP. SLOPE 1:12 FOR REMAINING 3” OF RISE. S EXIT SMOKE EMERGENCY LIFE SAFETY NOTES EXISTING SPRINKLER SYSTEM TO BE RECONFIGURED AS NECESSARY TO COMPLY WITH CODES. 1. EMERGENCY GFI ELECTRICAL NOTES GENERAL CONTRACTOR TO COORDINATE LOCATION OF THERMOSTATS WITH HVAC SUBCONTRACTOR. DIRECT QUESTIONS TO DESIGNER. REQUIREMENTS. GENERAL CONTRACTOR TO COORDINATE. SMOKE DETECTORS ARE REQUIRED AS PER THE LOCAL FIRE DEPARTMENTS 2. LIFE SAFETY LEGEND STROBE WALL MTD. EMERGENCY LIGHTING WITH BATTERY PACK BACK-UP. SMOKE DETECTOR CEILING MOUNTED, EDGE LIT LED GREEN EXIT SIGN WITH BATTERY BACK-UP. ELECTRICAL LEGEND S SMOKE EXIT WALL MOUNTED - MOTION DETECTOR OUTLET - DUPLEX GROUND FAULT INTERRUPTER *** ALL LIFE SAFETY FIXTURES BY GC 1. CEILING MOUNTED MOTION DETECTOR FLUSH MOUNTED CEILING LIGHT WALL SCONCE LIGHT NOT USEDC2 C1 W1 M M SPRINKLE ACCORDING TO CODE NEW GWB CEILING EL= 7'-3" MIN. C1 REFLECTED CEILING PLAN Scale: 1/2" = 1'-0"1 POSSIBLE CEILING LOCATION FOR HVAC MECHANCIAL EQUIPMENT.W1C1NEW LIGHT FIXTURE AT LOCATION OF EXISTING. REUSE AND RELOCATE CURRENT FIXTURE TO MOP CLOSET. 4 LIGHT FIXTURE CURRENTLY IN HALLWAY. PLACE IN NEW LOCATION. NEW FRAMING SEE STRUCTURALS 6 A-102 M C1 C1 C1 C1 CENTER OVER SINKSCENTER OVER SINKS CENTER LIGHTS BETWEEN PARTITIONS CEILING MOUNTED PARTITION BRACKETS M C1