A-103Renovations to:
THORNES
MARKETPLACE
MEN'S TOILET
ROOM
FIRST FLOOR
150 MAIN STREET,
Northampton,
Massachusetts
REGISTERED ARCHITECT,
COMMONWEALTH OF
MASSACHUSETTS
This drawing is not intended nor shall it be
used for construction purposes unless the
Signed professional seal of Emily Estes
Baillargeon is affixed in the space below. The
Architect shall be deemed the author of these
documents and shall retain all common law,
statutory and other reserved rights, including
the copyright.
Rev Date Description
Project Title
Issue Date:
Drawn By:
Checked By:
Project ID:
Drawing No.
Project North
1 02/06/15 SCHEMATIC PROGRESS
Sheet Title
Scale:
02/05/2015
EEB
JPB
2015-02
AS NOTED
FIELD VERIFY ALL DIMENSIONS2 02/24/15 REVISIONS
3 02/24/15 REVISIONS
4 03/03/15 REVISIONS
WWW.ESTESARCHITECT.COM
EMILY ESTES
ARCHITECTURE + DESIGN
5 12/23/15 REVISIONS
6 1/19/16 PERMIT SET
7 2/1/16 REVISIONS
PARTIAL
SECTION AND
FRAMING
PLAN
A-103FRAMING PLAN
1/2" = 1'-0"3
NOTE: SEE STRUCTURAL NARRATIVE FOR
STRUCTURAL SPECIFICATIONS AND SIZES..
6
A-102
UP
DN
NOTE: SEE STRUCTURAL NARRATIVE FOR
STRUCTURAL SPECIFICATIONS AND SIZES..
NEW RAISED WOOD
FRAMING FOR HEIGHT
CLEARANCE OF TOILET
ROOM BELOW. SEE
STRUCTURAL
NARRATIVE.
MODIFY EXISTING
DOOR AS NEEDED TO
ACCOMMODATE NEW
RAISED FLOOR.
EXISTING STORAGE
AREA BETWEEN FIRST AND
SECOND FLOOR.
EXISTING PANEL BOARD
TO REMAIN
EXISTING BUILT IN
SHELVING
3
EXISTING SECTION DETAIL
Scale: 1" = 1'-0"1 7'-0"6'-2"REMOVE EXISTING
CEILING AND 2X4
FRAMING TO RAISE
CEILING.
EXISTING PANEL
BOARD TO REMAIN
EXISTING 2ND FLOOR
WOOD FRAMING TO
REMAIN.
EXISTING FIRST FLOOR
+0'-0"
EXISTING FIRST FLOOR CEILING
+7'-0"
BOTTOM OF EXT STORAGE CEILING
+13'-7"
EXISTING SPRINKLER
PIPE TO REMAIN
5'-4"1'-4"
EXISTING WOOD
BEADBOARD CEILING
TO REMAIN
EXISTING 2X4
STRAPPING
REMOVE EXISTING
SINK
REMOVE ALL EXISTING FINISHES
EXISTING MEN'S ROOM
EXISTING STORAGE ROOM
EXISTING WOMEN'S ROOM
EXISTING BUILT-IN
SHELVING
PROPOSED SECTION DETAIL
Scale: 1" = 1'-0"2 5'-2 1/8"EXISTING PANEL
BOARD TO REMAIN
EXISTING 2ND FLOOR
WOOD FRAMING TO
REMAIN.
EXISTING FIRST FLOOR
+0'-0"
EXISTING FIRST FLOOR CEILING
+7'-0"
BOTTOM OF EXT STORAGE CEILING
+13'-7"
RELOCATE EXISTING
SPRINKLER PIPES TO
INCREASE HEAD
CLEARANCE
1'-4"
EXISTING WOOD
BEADBOARD CEILING
TO REMAIN
EXISTING 2X4
STRAPPING
1/2” PLYWOOD
SHEATHING
EXISTING MEN'S ROOM
EXISTING STORAGE ROOM
EXISTING WOMEN'S ROOM
EXISTING BUILT-IN
SHELVING
RAISE AND LEVEL EXISTING
FLOOR FOR DIFFERENCE OF
6” TO EXISTING GROUND
FLOOR7'-0 3/4"5/8” PAINTED M.R. GWB
6"1'-7"NEW FIRST FLOOR
+0'-6"
NEW FIRST FLOOR CEILING
+7'-7"
NEW WOOD FRAMING. SEE
STRUCTURAL DOCS.
SAME CLEARANCE AS
EXISTING CONDITION
REMOVE BASE OF
EXISTING BUILT-IN
SHELF FOR NEW
FRAMING1'-7"6'-8" MIN CLEARANCE2'-0"4"2'-6"2'-3"8" MIN NEW ACCESSIBLE WALL HUNG
SINK
6" 7'-0" MIN CLEARANCEEXISTING GROUND FLOOR
7