Loading...
32C-003 bank of america doors MA7-197_Northampton SGVD_100% CD's_20151207Gensler Architect One Beacon Street 3rd Floor Boston MA 02108 Telephone: 617.619.5700 Attn: Julie Reker GENSLER PROJECT NUMBER: CBRE Project Name: Project Management 41 Crestfield Lane Leominster, MA 01453 t: 978.660.7068 Attn: Carl Wall CB Richard EllisManhattan ID: CBRE Project Number:10027323 12/07/2015 Issue for 100% CDs SLIDING GLASS VESTIBULE DOOR REPLACEMENT 144 Main Street Northampton, MA 01060 SLIDING GLASS VESTIBULE DOOR REPLACEMENT11.6561.05712-07-2015Issue for 100% CDs144 Main Street Northampton, MA 01060 MA, Northamptom, 144 Main Street, Sliding Glass Doors ( SGVD) Replacement Project MA7-197 11.6561.057 OCCUPANCY TYPE: CONSTRUCTION TYPE: PROJECT AREA: BUILDING ADDRESS: 144 MAIN ST. NORTHAMPTON MA 01060 BUSINESS GROUP B EXISTING 800 s.f. PROJECT DESCRIPTION: SLIDING GLASS VESTIBULE DOOR REPLACEMENT BUILDING SUBCODE: MA STATE BUILDING CODE, 8th EDITION (IBC 2009) PLUMBING SUBCODE: MA STATE PLUMBING CODE MECHANICAL SUBCODE: MA STATE MECHANICAL CODE ELECTRICAL SUBCODE: MA ELECTRICAL CODE FIRE / LIFE SAFETY SUBCODE: MA FIRE PREVENTION REGULATIONS, 527 CMR 21 ENERGY CODE: ASHRAE 90.1 (MA STATE BUILDING CODE, ARTICLE 13 (780 CMR)) ACCESSIBILITY CODE: ARCHITECTURAL ACCESS REGULATIONS, CMR 521 APPLICABLE CODES XXX XXX OFFICE 04F06 A XXXX A 1 FV FVC FE FHC FEC XX AXX.XX XX AXX.XX SIMFL12.NW 1 FIRE ALARM PULL XX FIRE HOSE CABINET SMOKE PARTITION MILLWORK SCHEDULE TAG (IF USED) DOOR TYPE HARDWARE SET CONSTRUCTION ROOM NAME FLOOR LEVEL AND AREA OR PHASE DESCRIPTION OF SIMILAR OR OPPOSITE COLUMN GRID EXISTING CONSTRUCTION TO BE DEMOLISHED EXISTING CONSTRUCTION TO REMAIN NEW PARTITION ROOM NUMBER 1 HR. RATED PARTITION REFERENCE TO PARTITION TYPE KEY NOTE ALIGN WITH ESTABLISHED SURFACES REVISION REFERENCE MILLWORK AREA TO BE DETAILED SHEET WHERE SHOWN DETAIL NUMBER SHEET WHERE SHOWN ELEVATION NUMBER ON SHEET DIRECTION OF ELEVATION FIRE EXTINGUISHER CABINET FIRE VALVE CABINET FIRE VALVE WITHOUT CABINET FIRE EXTINGUISHER WITHOUT CABINET NOT IN CONTRACT ALIGN XXXX XXXX XXXX XXXX XXXX FINISH WALL FINISH BASE FINISH EXTENT OF FINISH WALL FINISH SPECIAL FINISH FLOOR FINISH CHANGE IN FLOOR FINISH ML ELECTRO-MAGNETIC LOCK B B H DR EH IA KS EL DR ES CR SECURITY DEVICES DOOR BELL REMOTE DOOR RELEASE BUTTON INTRUSION ALARM BELL PUSH BUTTON KEY SWITCH DOOR HOLD OPEN DOOR RELEASE ELECTRIC LOCKSET ELECTRIC STRIKE ELECTRIC HINGE CARD READER NON-FERROUS ALUMINUM CONCRETE CONCRETE MASONRY UNIT STONE WOOD (BLOCKING) WOOD (CONTINUOUS) WOOD (FINISH) PLYWOOD METAL GLASS (LARGE SCALE) INSULATION (LOOSE OR BATT) GYPSUM BOARD SECTION INDICATIONS CARPET ACOUSTICAL TILE FA XXXX CEILING FINISH XX SHEET NOTE AREA OF WORK Gensler One Beacon Street Third Floor Boston MA 02108 Tel: 617.619.5700 Fax: 617.619.5701 © 2015 Gensler Scale Description Project Number Project Name Seal/Signature NOT TO SCALE \\gensler.ad\Projects\RevitUserModels\19683\2015_BOA_Northampton SGVD_2014_19683.rvtA00.00 DRAWING INDEX 11.6561.057 SLIDING GLASS VESTIBULE DOOR REPLACEMENT 144 Main Street Northampton, MA 01060 A00.00 DRAWING INDEX 1 12/07/2015 ISSUE FOR 100% CD A00.10 GENERAL NOTES 1 12/07/2015 ISSUE FOR 100% CD A00.20 PARTITION TYPES, DOOR, HARDWARE & FINISH SCHEDULES 1 12/07/2015 ISSUE FOR 100% CD A00.40 TYPICAL ADA INFORMATION 1 12/07/2015 ISSUE FOR 100% CD A01.01 DEMOLITION PLAN AND DEMOLITION REFLECTED CEILING PLAN 1 12/07/2015 ISSUE FOR 100% CD A02.01 CONSTRUCTION PLAN AND REFLECTED CEILING PLAN 1 12/07/2015 ISSUE FOR 100% CD A12.00 AIRLOCK VESTIBULE DETAILS 1 12/07/2015 ISSUE FOR 100% CD A12.20 EXISTING CONDITION PHOTOS 1 12/07/2015 ISSUE FOR 100% CD DRAWING NUMBER DRAWING NAME CURRENT ISSUE CURRENT ISSUE DATE CURRENT ISSUE DESCRIPTION DRAWING INDEX ARCHITECTURAL VICINITY MAP LOCATION MAP PROJECT INFORMATION GENERAL NOTES 1 COMPLY WITH APPLICABLE LOCAL, STATE AND FEDERAL CODES AND REGULATIONS PERTAINING TO SAFETY OF PERSONS, PROPERTY AND ENVIRONMENTAL PROTECTION. 2 OBTAIN AND PAY FOR PERMITS AND INSPECTIONS REQUIRED BY PUBLIC AUTHORITIES GOVERNING THE WORK EXCEPT AS PROVIDED OTHERWISE IN THE SPECIFICATIONS OR OWNER CONTRACTOR AGREEMENT. 3 REVIEW DOCUMENTS, VERIFY DIMENSIONS AND FIELD CONDITIONS AND CONFIRM THAT WORK IS BUILDABLE AS SHOWN. REPORT ANY CONFLICTS OR OMISSIONS TO THE ARCHITECT FOR CLARIFICATION PRIOR TO PERFORMING ANY WORK IN QUESTION. 4 COORDINATE WORK WITH THE OWNER, INCLUDING SCHEDULING TIME AND LOCATIONS FOR DELIVERIES, BUILDING ACCESS, USE OF BUILDING SERVICES AND FACILITIES, AND USE OF ELEVATORS. MINIMIZE DISTURBANCE OF BUILDING FUNCTIONS AND OCCUPANTS. 5 OWNER WILL PROVIDE WORK NOTED "BY OTHERS" OR "NIC" UNDER SEPARATE CONTRACT. INCLUDE SCHEDULE REQUIREMENTS IN CONSTRUCTION PROGRESS SCHEDULE AND COORDINATE TO ASSURE ORDERLY SEQUENCE OF INSTALLATION. 6 MAINTAIN WORK AREAS SECURE AND LOCKABLE DURING CONSTRUCTION. COORDINATE WITH OWNER AND/OR PROPERTY MANAGER TO ENSURE SECURITY. 7 MAINTAIN EXITS, EXIT LIGHTING, FIRE PROTECTIVE DEVICES, AND ALARMS IN CONFORMANCE WITH APPLICABLE CODES AND ORDINANCES. 8 DO NOT SCALE DRAWINGS. WRITTEN DIMENSIONS GOVERN. IN CASE OF CONFLICT, CONSULT THE ARCHITECT. 9 PROVIDE AND MAINTAIN BARRICADES, LIGHTING, AND GUARDRAILS AS REQUIRED BY APPLICABLE CODES AND REGULATIONS TO PROTECT OCCUPANTS OF BUILDING AND WORKERS. 10 ERECT AND MAINTAIN DUSTPROOF PARTITIONS AS REQUIRED TO PREVENT SPREAD OF DUST, FUMES, AND SMOKE, ETC. TO OTHER PARTS OF THE BUILDING. ON COMPLETION, REMOVE PARTITIONS AND REPAIR DAMAGED SURFACES TO MATCH ADJACENT SURFACES. 11 IF DEMOLITION IS PERFORMED IN EXCESS OF THAT REQUIRED, RESTORE EFFECTED AREAS AT NO COST TO THE OWNER. 12 REMOVE FROM SITE DAILY AND LEGALLY DISPOSE OF REFUSE, DEBRIS, RUBBISH, AND OTHER MATERIALS RESULTING FROM DEMOLITION OPERATIONS. 13 REMOVE DESIGNATED PARTITIONS, COMPONENTS, BUILDING EQUIPMENT, AND FIXTURES AS REQUIRED FOR NEW WORK. 14 REMOVE ABANDONED HVAC EQUIPMENT, INCLUDING DUCT WORK. 15 REMOVE ABANDONED ELECTRICAL, CABLING AND DEVICES. 16 REPAIR EXISTING SURFACES TO REMAIN AS REQUIRED FOR APPLICATION OF NEW FINISHES. 17 WHERE EXISTING ACCESS PANELS CONFLICT WITH CONSTRUCTION, RELOCATE PANELS TO ALIGN WITH AND FIT WITHIN NEW CONSTRUCTION. 18 CONTRACTOR SHALL PROVIDE BLOCKING FOR ALL EQUIPMENT, MILLWORK & ACCESSORIES MOUNTED ON WALL. 19 CONTRACTOR SHALL PROVIDE COLOR SAMPLE FOR ALL FINISHES & P-LAM TO OWNER & ARCHITECT PRIOR TO ORDERING AND INSTALLATION. 20 PARTITIONS ARE DIMENSIONED FROM FINISH FACE TO FINISH FACE UNLESS OTHERWISE NOTED. MAINTAIN DIMENSIONS MARKED AS "CLEAR". ALLOW FOR THICKNESS OF FINISHES. 21 G.C. SHALL PROVIDE ALL WORK RELATED TO ENGINEERING TO INCLUDE, BUT NOT LIMITED TO: MECHANICAL, ELECTRICAL, FIRE PROTECTION & LIFE SAFETY. G.C. SHALL PROVIDE DESIGN DRAWINGS, PERMITS & INSTALLATION OF SYSTEMS ON A DESIGN BUILD BASIS. J JAN JANITOR K KIT KITCHEN L LAV LAVATORY LB POUND LOUVER LOUVER LT LIGHT LVLG LEVELING M M.E. MATCH EXISTING MAX MAXIMUM MECH MECHANICAL MEMB MEMBRANE MET METAL MEZZ MEZZANINE MFD MANUFACTURED MFR MANUFACTURER MIN MINIMUM MISC MISCELLANEOUS MLWK MILLWORK MOIST MOISTURE MOT MOTOR(IZED) MTD MOUNTED N NIC NOT IN CONTRACT NO NUMBER NTS NOT TO SCALE O OPNG OPENING(S) OPR OPERABLE ORNA ORNAMENTAL OS OCCUPANCY SENSOR OVFL OVERFLOW OVHD OVERHEAD P PBD PARTICLE BOARD PEDTR PEDESTRIAN PLAM PLASTIC LAMINATE PLAS PLASTER PLSTC PLASTIC PLYWD PLYWOOD PNL PANEL POLYST POLYSTYRENE PORT PORTABLE PREFAB PREFABRICATED PREFIN PREFINISHED PRTECN PROTECTION PTN PARTITION R RDR READER RECES RECESS(ED) RECPT RECEPTACLE REF REFER(ENCE) REFL REFLECTED REFR REFRIGERATOR REQD REQUIRED RESIS RESIST(ANT)(IVE) RFG ROOFING RM ROOM RO ROUGH OPENING S SCR SCRIBE SECUR SECURITY SF SQUARE FEET SGL SINGLE SHORG SHORING SIM SIMILAR SST STAINLESS STEEL STD STANDARD STL STEEL STRFR STOREFRONT STRUCT STRUCTURAL SURF SURFACE SUSP SUSPENDED SYS SYSTEM(S) T T&G TONGUE AND GROOVE THK THICK TLT TOILET TRAF TRAFFIC TRANS TRANSPARENT TRTD TREATED TYP TYPICAL U UNDRLAY UNDERLAYMENT UON UNLESS OTHERWISE NOTED UTIL UTILITY V VEH VEHICLE VERT VERTICLE VIF VERIFY IN FIELD W W/ WITH W/O WITHOUT WC WATER CLOSET WD WOOD WDW WINDOW WT WEIGHT WTRPRF WATERPROOFING A ACCES ACCESSORY ACOUS ACOUSTIC(AL) AFF ABOVE FINISHED FLOOR AL ALUMINUM ALT ALTERNATE ANNUNC ANNUNCIATOR ANOD ANODIZED APPL APPLIANCE AUTO AUTOMATIC AVG AVERAGE B BD BOARD BLDG BUILDING BLKG BLOCKING BOLLD BOLLARD BRDLM BROADLOOM BU BUILT UP C CAB CABINET CEM CEMENT(ITIOUS) CER CERAMIC CLG CEILING CMU CONCRETE MASONRY UNIT COATG COATING COILG COILING CONC CONCRETE CONSTR CONSTRUCTION CONT CONTINUOUS(ATION) CONTR CONTRACT(OR) COV COVER CPT CARPET D DBL DOUBLE DEPT DEPARTMENT DES DESIGN(ED) DET DETAIL DF DRINKING FOUNTAIN DIA DIAMETER DIFF DIFFUSER DIM DIMENSION DISP DISPENSER DIV DIVISION DN DOWN DR DOOR DSCON DISCONNECT DWR DRAWER E ELAST ELASTOMERIC ELEC ELECTRICAL EMBED EMBEDD(ED)(ING) ENGR ENGINEER(ED) ENTR ENTRANCE EQ EQUAL EQUIP EQUIPMENT EX EXISTING EXP JT EXPANSION JOINT EXPS EXPOSE(D) EXT EXTERIOR F FAB FABRICATION FD FLOOR DRAIN FE FIRE EXTINGUISHER FE&C FIRE EXTINGUISHER AND CABINET FHC FIRE HOSE CABINET FIN FINISH FLDG FOLDING FLR FLOOR(ING) FPLC FIREPLACE FR FIRE RAT(ING)(ED) FRMG FRAMING FURN FURNITURE FWC FABRIC WALL COVERING FXD FIXED FXTR FIXTURE G GA GAUGE GFCI GROUND FAULT CIRCUIT INTERRUPTER GFRC GLASS FIBER REINFORCED CONCRETE GFRG GLASS FIBER REINFORCED GYPSUM GFRP GLASS FIBER REINFORCED PLASTER GL GLASS GR GRAD(E)(ING) GYP GYPSUM H HD HEAD HDWD HARDWOOD HDWE HARDWARE HM HOLLOW METAL HORIZ HORIZONTAL HVAC HEATING, VENTILATING, AND AIR CONDITIONING I INFILTR INFILTRATION INFO INFORMATION INSTRUM INSTRUMENT(ATION) INSUL INSULATION INT INTERIOR INTLK INTERLOCK(ING) ABBREVIATIONS GRAPHIC SYMBOLS Ref. North Ref. North PROJECT LOCATION PROJECT LOCATION SITE PLAN Ref. North BANK OF AMERICA OLD STREETMAI N STREET Issue #Issue Date Issue Description 1 12/07/2015 ISSUE FOR 100% CD Gensler One Beacon Street Third Floor Boston MA 02108 Tel: 617.619.5700 Fax: 617.619.5701 © 2015 Gensler Scale Description Project Number Project Name Seal/Signature NOTE: EVERY KEY NOTE MAY NOT APPEAR ON THIS PAGE \\gensler.ad\Projects\RevitUserModels\19683\2015_BOA_Northampton SGVD_2014_19683.rvtA00.10 GENERAL NOTES 11.6561.057 SLIDING GLASS VESTIBULE DOOR REPLACEMENT 144 Main Street Northampton, MA 01060 GENERAL NOTESFIRE DEPARTMENT NOTES 1 PROVIDE EXIT SIGN WITH 6" LETTERS OVER REQUIRED EXITS, WHERE SHOWN ON DRAWINGS, AND ADDITIONAL SIGNS AS REQUIRED BY BUILDING DEPARTMENT INSPECTOR OR FIRE DEPARTMENT FIELD INSPECTOR. CONNECT EXIT SIGNS TO EMERGENCY POWER CIRCUITS. COMPLY WITH BUILDING CODES. 2 MAINTAIN AISLES AT LEAST 44" WIDE AT PUBLIC AREAS. 3 EVERY EXIT DOOR SHALL BE OPERABLE FROM THE INSIDE WITHOUT THE USE OF A KEY OR ANY SPECIAL KNOWLEDGE OR EFFORT. SPECIAL LOCKING DEVICES SHALL BE OF AN APPROVED TYPE. ALL NEW DOORS SHALL HAVE APPROVED LEVER HANDLES. 4 DOOR OPENINGS INTO REQUIRED 1-HOUR, FIRE-RESISTIVE CORRIDORS SHALL BE PROTECTED WITH A SMOKE OR DRAFT STOP ASSEMBLY HAVING A 20 MINUTE RATING AND SHALL BE SELF-CLOSING. 5 20-MINUTES DOOR JAMBS TO BE TIGHT-FITTIN, SMOKE AND DRAFT CONTROLLED. 6 EXIT DOORS SHALL SWING IN THE DIRECTION OF TRAVEL WHEN SERVING 50 OR MORE PERSONS AND IN ANY HAZARDOUS AREAS. 7 INTERIOR WALL AND CEILING FINISHES FOR EXIT CORRIDORS SHALL NOT EXCEED AND END POINT FLAME SPREAD RATING: 8 CLASS I, FLAME SPREAD 0-25, SMOKE DENSITY 150, FOR MATERIALS INSTALLED IN VERTICAL EXITS. 9 CLASS II, FLAME SPREAD 26-75, SMOKE DENSITY 300, FOR MATERIALS INSTALLED IN HORIZONTAL EXITS. 10 CLASS III, FLAME SPREAD 76-200, SMOKE DENSITY OF 450, FOR MATERIALS INSTALLED IN ANY OTHER LOCATION. 11 PROVIDE FIRE DAMPERS OR DOORS WHERE AIR DUCTS PENETRATE FIRE-RATED WALLS OR CEILINGS. 12 WOOD BLOCKING SHALL BE FIRE-TREATED IN ACCORDANCE WITH APPLICABLE CODES. 13 HEARING IMPAIRED: FLASHING VISUAL WARNINGS SHALL HAVE A FREQUENCY OF NOT MORE THAN 60 FLASHES PER MINUTE, AND SHALL BE SYNCHRONIZED. 14 LOCATE THE CENTER OF FIRE ALARM INITIATING DEVICES 48" ABOVE THE LEVEL OF THE FINISHES FLOOR, WORKING PLATFORM, GROUND SURFACE OR SIDEWALK. 15 CONTRACTOR SHALL PERMANENTLY INDENTIFY ALL PROTECTED OPENINGS, CORRIDOR PARTITIONS, SMOKE STOP PARTITIONS, HORIZONTAL EXIT PARTITIONS, EXIT ENCLOSURES AND ALL FIRE RATE WALLS WITH CORRESPONDING HOURLY RATING BY EITHER INSTALLING SIGNS OR BY STENCILING IN CONCEALED SPACES THE FOLLOWING: "1 HOUR FIRE AND SMOKE BARRIER - PROTECT ALL OPENINGS." NOTE: IDENTIFICATION SHALL BE SPACED NO MORE THAN TWELVE (12) FEET ON CENTER WITH A MINIMUM LETTER SIZE OF TWO (2) INCHES IN HEIGHT ON A CONTRASTING BACKGROUND. 25 OWNER WILL PROVIDE WORK NOTED "BY OTHERS" OR "NIC" UNDER SEPARATE CONTRACT. INCLUDE SCHEDULE REQUIREMENTS IN CONSTRUCTION PROGRESS SCHEDULE AND COORDINATE TO ASSURE ORDERLY SEQUENCE OF INSTALLATION 26 COORDINATE TELECOMMUNICATIONS, DATA AND SECURITY SYSTEM INSTALLATIONS. 27 PROTECT AREA OF WORK AND ADJACENT AREAS FROM DAMAGE. 28 DO NOT SCALE DRAWINGS. WRITTEN DIMENSIONS GOVERN. IN CASE OF CONFLICT, CONSULT THE ARCHITECT. 29 COORDINATE AND PROVIDE BLOCKING FOR MILLWORK AND ITEMS ATTACHED OR MOUNTED TO WALLS OR CEILINGS. 30 UNDERCUT DOORS TO CLEAR TOP OF FLOOR FINISHES BY 1/4 INCH, UNLESS OTHERWISE NOTED. 31 CONCEALED INSULATING MATERIALS INSTALLED WITHIN WALL SHALL HAVE A FLAME SPREAD INDEX OF NOT MORE THAN 75 AND A SMOKE-DEVELOPED INDEX OF MOT MORE THAN 450. 32 INSULATING MATERIALS WHICH ARE SUBJECT TO DIRECT EXPOSURE TO POTENTIAL FIRE ON THE INSIDE OF THE BUILDING DUE TO INSTALLATION IN UNCONCEALED SPACES SHALL HAVE A FLAME SPREAD INDEX OF NOT MORE THAN 25 AND A SMOKE-DEVELOPED INDEX OF NOT MORE THAN 450. 33 MATERIALS EXPOSED WITHIN PLENUMS ARE REQUIRED TO BE NONCOMBUSTIBLE OR SHALL HAVE A FLAME SPREAD INDEX OF NOT MORE THAN 25 AND A SMOKE-DEVELOPED INDEX OF NOT MORE THAN 50 AS DETERMINED IN ACCORDANCE WITH ASTM E 84. 1 ALL WORK SHALL CONFORM TO THE AMERICAN WITH DISABILITIES ACT (A.D.A.) ALONG WITH ALL STATE, COUNTY, AND LOCAL APPLICABLE CODES, ORDERS, ORDINANCES AND REGULATIONS. NOTIFY ARCHITECT PRIOR TO START OF WORK OF ANY DISCREPANCIES BETWEEN THE DRAWINGS AND CODE. ALL WORK SHALL CONFORM TO THE MOST RESTRICTIVE REQUIREMENT. 2 BEFORE COMMENCING WORK, CONTRACTOR SHALL BECOME FAMILIAR WITH DRAWINGS SCOPE OF WORK AND VERIFY EXISTING CONDITIONS AND DIMENSIONS AT THE SITE AND NOTIFY THE ARCHITECT OF ANY DISCREPANCIES. 3 PRIOR TO STARTING WORK, THE GENERAL CONTRACTOR SHALL SUBMIT TO BANK OF AMERICA PROJECT MANAGER AND ARCHITECT AN ITEMIZED COST BREAKDOWN OF ALL SCOPE ITEMS AND A CONSTRUCTION SCHEDULE. WORK TO BE SCHEDULED TO MEET BANK OF AMERICA REQUIREMENTS. 4 ALL WORK DESCRIBED OR INDICATED IN THESE DOCUMENTS AND ALL WORK DEPENDENT UPON OR NECESSARY TO COMPLETE THIS WORK SHALL BE EXECUTED IN A WORKMAN LIKE MANNER CONSISTENT WITH THE BEST STANDARDS OF THE TRADE INVOLVED AND BE OF ITEMS AND MATERIALS SUITED FOR THE PURPOSE INTENDED. 5 TRADESMEN, CRAFTSMEN, INSTALLERS, FOREMEN, AND SUPERVISORS ARE TO BE SKILLED, EXPERIENCED AND LICENSED IF REQUIRED IN THE WORK THEY WILL BE PERFORMING. 6 PROJECT CONSTRUCTION ITEMS TO BE NEW, UNLESS OTHERWISE NOTED. NO SUBSTITUTIONS WILL BE ALLOWED UNLESS COMPLETE DESCRIPTIONS OF ITEMS INCLUDING DRAWINGS, TEST DATA, SAMPLES, COST AND SCHEDULE CHANGES ARE SUBMITTED BY THE CONTRACTOR AND APPROVED BY THE ARCHITECT PRIOR TO INSTALLATION. ANY ITEM NOTED ON THE DRAWINGS THAT ARE NOT AVAILABLE OR WOULD CAUSE A TIME DELAY SHALL BE IDENTIFIED BY THE GENERAL CONTRACTOR AND THE ARCHITECT NOTIFIED. 7 TYPICAL DETAILS AND GENERAL NOTES SHALL BE USED WHENEVER APPLICABLE U.N.O. ALL SYMBOLS AND ABBREVIATIONS USED ON THE DRAWINGS ARE CONSIDERED CONSTRUCTION STANDARDS. IF CONTRACTOR HAS ANY QUESTIONS REGARDING THE SAME OR EXACT MEANING, ARCHITECT SHALL BE NOTIFIED FOR CLARIFICATION. 8 DIMENSION LINES ARE TO FACE OF FINISH ON EXISTING AND NEW WORK, UNLESS NOTED AS FACE OF STUD OR MASONRY OR CENTERLINE OR OTHERWISE. DIMENSIONS SHALL HAVE PRECEDENCE OVER SCALE AND LARGER SCALE DRAWINGS SHALL HAVE PRECEDENCE OVER SMALLER SCALE DRAWINGS. 9 PROVIDE SHOP DRAWINGS WHERE INDICATED AND FOR ALL METAL FABRICATION OR WHERE THEY ARE CALLED OUT FOR ON THE CONSTRUCTION DOCUMENTS. THE CONTRACTOR SHALL SUBMIT FIVE (5) SETS TO THE ARCHITECT WITH AMPLE TIME TO REVIEW. REQUIRED CORRECTIONS WILL BE NOTED AND A COPY WILL BE RETURNED TO THE CONTRACTOR WHO SHALL REVISE DRAWINGS AND RESUBMIT FOR FINAL APPROVAL PRIOR TO FABRICATION. 10 CONTRACTOR TO SUBMIT SAMPLES OF ALL FINISH MATERIALS TO ARCHITECT FOR APPROVAL PRIOR TO INSTALLATION. 11 CONTRACTOR SHALL MAINTAIN A COMPLETE SET OF AS-BUILT DRAWINGS NOTING DEVIATIONS BETWEEN THESE DRAWINGS AND ACTUAL FIELD CONDITIONS AND NEW CONSTRUCTION OF ALL TRADES AND DELIVER TO BANK OF AMERICA AT END OF PROJECT. GENERAL CONTRACTOR SHALL PROVIDE ALL SUBCONTRACTORS WITH THE MOST CURRENT CONSTRUCTION DOCUMENTS THROUGHOUT THE PROJECT, INCLUDING ALL REVISIONS. 12 CONTRACTOR TO NOTIFY ARCHITECT AND BANK OF AMERICA PROJECT MANAGER OF ALL REVISIONS TO THE DRAWINGS AND CHANGES WITH THE SCOPE OF WORK OR SCHEDULE REQUIRED BY GOVERNING AGENCIES, FIELD CONDITIONS OR BANK OF AMERICA PERSONNEL REGARDLESS OF EXTENT. ALL REVISIONS TO BE IN WRITING AS CHANGE ORDERS AND APPROVED PRIOR TO STARTING WORK. 13 CONTRACTOR TO PROVIDE EQUIPMENT TO ENSURE LIFE SAFETY OF PUBLIC, TENANTS AND WORKERS AS REQUIRED BY FEDERAL, STATE AND LOCAL CODES THROUGHOUT CONSTRUCTION. CONTRACTOR SHALL TAKE ALL NECESSARY MEASURES TO PROTECT PEDESTRIANS. 14 CONTRACTOR TO VERIFY EXISTING STRUCTURAL CONDITIONS AND REQUIREMENTS OF NEW CONSTRUCTION PRIOR TO START OF WORK. CONTRACTOR SHALL FURNISH ADEQUATE SHORING, BRACING, ETC. AS REWIRED TO SAFELY EXECUTE ALL WORK AND SHALL BE FULLY RESPONSIBLE FOR SAME, UNLESS SPECIFICALLY DETAILED IN THE DRAWINGS. CONTRACTOR SHALL PROVIDE BLOCKING, BACKING, FRAMING, HANGERS, OR OTHER SUPPORTS AS NECESSARY FOR ALL FIXTURES, EQUIPMENTS AND ALL OTHER ITEMS REQUIRING SAME. 15 SITE AND BUILDING SHALL BE MAINTAINED IN A CLEAN, SAFE MANNER, DIRTY/ NOISY WORK SHALL BE PERFORMED AT SUCH TIME AS DIRECTED PER THE OWNER AND/OR CITY WHEN THE WORK VARIOUS SECTIONS ARE COMPLETED, AND AT OTHER TIMES AS DIRECTED BY BANK OF AMERICA, OR OWNER, ALL TRASH DEBRIS, SURPLUS MATERIAL, TOOLS AND EQUIPMENT TO BE REMOVED FROM THE SITE AND DISPOSED OF IN A LEGAL MANNER. LEAVE PREMISES IN A CONDITION ACCEPTABLE TO BANK OF AMERICA, OR OWNER. 16 PROTECT AREA OF WORK AND ADJACENT AREAS FROM DAMAGE. WHERE EXISTING CONSTRUCTION, FINISHES OR EQUIPMENT IS DAMAGED BY WORK IN THIS CONTRACT, THEY SHALL BE PATCHED, REPAIRED OR REPLACED AS REQUIRED TO MATCH EXISTING, BY TRADE WHOSE WORK IS DAMAGED AT NO COST TO BANK OF AMERICA. 17 LOCATION AND ELEVATION OF ALL WORK TO BE CONSTRUCTED ARE SHOWN ON DRAWINGS AND UNLESS DISCREPANCIES ARE BROUGHT TO THE ATTENTION OF THE ARCHITECT PRIOR TO CONSTRUCTION, THE CONTRACTOR WILL BE HELD RESPONSIBLE FOR THE PROPER LOCATION AND ELEVATIONS AS SHOWN AND INTENDED. 18 THE CONTRACTOR SHALL LAYOUT THE WORK AND SHALL ESTABLISH AND MAINTAIN NECESSARY MARKERS, AND SHALL BE RESPONSIBLE FOR THE ACCURACY OF SAME. THE CONTRACTOR SHALL LAYOUT, AS A GUIDE TO ALL TRADES AND TO HIS SUBCONTRACTORS, THE EXACT LOCATIONS OF NEW OR REMODEL WORK WITH RESPECT TO CHANGES TO EXISTING. 19 INSTALL AND APPLY ITEMS, MATERIALS, EQUIPMENT, FINISHES, ETC. INCLUDING THE PREPARATION OF SURFACES IN STRICT ACCORDANCE WITH THE MANUFACTURER'S PRINTED RECOMMENDATIONS AND INSTALLATION REQUIREMENTS. 20 PERTAINING TO EQUIPMENT: GENERAL CONTRACTOR IS RESPONSIBLE FOR THE REMOVAL AND RELOCATION OF ANY EXISTING EQUIPMENT OR CONSTRUCTION AS NECESSARY FOR A COMPLETE INSTALLATION. 21 ACCESS PANELS SHALL BE PROVIDED FOR ALL EQUIPMENT SWITCHES, VALVES AND OTHER CONTROL DEVICES THAT ARE CONCEALED. EXACT LOCATIONS TO BE APPROVED BY ARCHITECT PRIOR TO INSTALLATION. 22 BESIDES GUARANTEES REQUIRED ELSEWHERE, THECONTRACTOR SHALL, HEREBY DOES, GUARANTEE ALL WORK FOR A MINIMUM PERIOD OF ONE YEAR AFTER DATE OF ACCEPTANCE OF WORK WITH ANY OTHER WORK, WHICH MAY BE DISPLACED IN SO DOING, THAT MAY PROVE DEFECTIVE IN WORKMANSHIP AND/OR MATERIALS WITHIN A MINIMUM OF ONE YEAR PERIOD FROM THE DATE OF ACCEPTANCE WITHOUT EXPENSE TO BANK OF AMERICA. 23 OBTAIN AND PAY FOR PERMITS AND INSPECTIONS REQUIRED BY PUBLIC AUTHORITIES GOVERNING THE WORK. 24 SUBMIT REQUESTS FOR SUBSTITUTIONS, REVISIONS, OR CHANGES TO ARCHITECT FOR REVIEW PRIOR TO PURCHASE, FABRICATION OR INSTALLATION. DISABLED ACCESS NOTES 1 THE AMERICANS WITH DISABILITES ACT (A.D.A.) PROVIDES THAT ALL ALTERATIONS TO A FACILITY MUST BE MADE IN SUCH A MANNER THAT, TO THE MAXIMUM EXTENT FEASIBLE, THE ALTERED PORTIONS OF THE FACILITY ARE READILY ACCESSIBLE TO INDIVIDUALS WITH DISABILITIES. BANK AND GENERAL CONTRACTOR ACKNOWLEDGES THAT THE REQUIREMENTS OF A.D.A. WILL BE SUBJECT TO VARIOUS AND POSSIBLY CONTRADICTORY INTERPRETATIONS. THE ARCHITECT THEREFORE, WILL USE IT'S BEST PROFESSIONAL EFFORTS TO INTERPRET A.D.A. REQUIREMENTS AND OTHER FEDERAL, STATE AND LOCAL LAWS, RULES, CODES ORDINANCES AND REGULATIONS AS THEY APPLY TO THE PROJECT. THE ARCHITECT, HOWEVER, CANNOT AND DOES NOT WARRANT OR GUARANTEE THAT BANK OF AMERICA WILL COMPLY WITH ALL INTERPRETATIONS OF THE A.D.A. REQUIREMENTS AND/OR THE REQUIREMENTS OF OTHER FEDERAL, STATE AND LOCAL LAWS, RULES, CODES, ORDINANCES AND REGULATIONS AS THEY APPLY TO THE PROJECT. 2 THE SCOPE OF WORK INDICATED IN THESE DRAWINGS IS FOR SPECIFIC ITEMS SELECTED BY BANK OF AMERICA FOR CUSTOMER ACCESS TO GOODS AND SERVICES. NOTE THAT SOME AREAS OF ACCESS HAVE NOT BEEN MODIFIED TO MEET A.D.A. REQUIREMENTS. ALL OTHER AREAS OF A.D.A. UPGRADE THAT MAY BE REQUIRED AT THIS TIME ARE NOT IN THIS CONTRACT AND ARE NOT INDICATED ON THESE DOCUMENTS. SEE BANK OF AMERICA FOR ADDITIONAL INFORMATION CONCERNING OTHER AREAS OF A.D.A. SCOPE OF WORK. 3 IN BUILDING AND FACILITIES, FLOORS OF A GIVEN STORY SHALL BE A COMMON LEVEL THROUGHOUT, OR SHALL BE CONNECTED BY PEDESTRIAN RAMPS, PASSENGER ELEVATORS OR SPECIAL ACCESS LIFTS. 4 FLOOR SURAFCES SHALL BE SLIP-RESISTANT. 5 EVERY CORRIDOR AND AISLE SERVING AN OCCUPANT LOAD OF 10 OR MORE, SHALL BE NOT LESS THAN 44" IN WIDTH. 6 ABRUPT CHANGES IN LEVEL ALONG ANY ACCESSIBLE ROUTE SHALL NOT EXCEED 1/2" IN HEIGHT. LEVEL CHANGES NOT EXCEEDING 1/4" MAY BE VERTICAL. BEVEL OTHERS WITH A SLOPE NOT GREATER THAN 1:2. 7 LATCHING AND LOCKING DOORS THAT ARE HAND ACTIVATED AND WHICH ARE IN A PATH OF TRAVEL SHALL BE OPERABLE WITH A SINGLE EFFORT BY LEVER. TYPE HARDWARE, PANIC BARS, PUSH-PULL ACTIVATING BARS, OR OTHER HARDWARE DESIGNED TO PROVIDE PASSAGE WITHOUT REQUIRING THE ABILITY TO GRASP THE OPENING HARDWARE. MOUNT DOOR OPENING HARDWARE BETWEEN 30" AND 44" ABOVE FLOOR FINISH. 8 CENTER HAND ACTIVATED DOOR OPENING HARDWARE BETWEEN 30" AND 44" ABOVE THE FLOOR. 9 MAXIMUM PULL OR PUSH EFFORT TO OPERATE DOORS SHALL NOT EXCEED 8.5 POUNDS FOR EXTERIOR DOORS AND 5 POUNDS FOR INTERIOR DOORS, MEASURED AT RIGHT ANGLES TO HINGED DOORS AND AT CENTER PLANE OF SLIDING OR FOLDING DOORS. CORRESPONDING DEVICES OR AUTOMATIC DOOR OPERATORS MAY BE UTILIZED TO MEET THE ABOVE STANDARDS. MAXIMUM EFFORT TO OPRATE REQUIRED FIRE DOORS MAY BE INCREASED NOT TO EXCEED 15 POUNDS. 10 THE BOTTOM 10" OF ALL DOORS (EXCEPT SLIDING AND AUTOMATIC) SHALL HAVE A SMOOTH UNINTERRUPTED SURFACE TO ALLOW THE DOOR TO BE OPENED BY A WHEELCHAIR FOOTREST WITHOUT CREATING A TRAP OR HAZARDOUS CONDITION. PROVIDE A 10" HIGH SMOOTH PANEL ON THE PUSH SIDE OF NARROW FRAME DOORS. 11 EVERY REQUIRED ENTRANCE OR PASSAGE DOORWAY SHALL NOT BE LESS THAN 3' IN WIDTH IN NOT LESS THAN 6'-8" IN HEIGHT. DOORS SHALL BE CAPABLE OF OPENING AT LEAST 90 DEGREES AND SHALL BE SO MOUNTED THAT THE CLEAR WIDTH OF THE DOORWAY IS NOT LESS THAN 32". 12 WHERE A PAIR OF DOORS IS UTILIZED, AT LEAST ONE OF THE DOORS SHALL PROVIDE A CLEAR, UNOBSTRUCTED OPENING WIDTH OF 32" WITH THE LEAF POSITIONED AT AN ANGLE OF 90 DEGREES FROM ITS CLOSED POSITION. 13 IDENTIFY ACCESSIBLE ENTRANCES WITH AT LEAST ONE STANDARD SIGN AND WITH ADDITIONAL DIRECTIONAL SIGNS, AS REQUIRED, VISIBLE FROM APPROACHING PEDESTRIAN WAYS. 14 THE FLOOR OR LANDING ON EACH SIDE OF AN ENTRANCE OR PASSAGE DOOR SHALL BE LEVEL AND CLEAR. THE LEVEL AND CLEAR RAEA SHALL HAVE A LENGTH IN THE DIRECTION OF DOOR SWING OF AT LEAST 60" AND THE LENGTH OPPOSITE THE DIRECTION OF DOOR SWING OF 48" AS MEASURED AT RIGHT ANGLES TO THE PLANE OF THE DOOR IN ITS CLOSED POSITION. 15 FLOORS AND LANDINGS SHALL BE NOT MORE THAN 1/2" LOWER THAN THE THRESHOLD OF THE DOORWAY. CHANGE IN LEVEL BETWEEN 1/4" AND 1/2" SHALL BE BEVELED WITH A SLOPE NO GREATER THAN 1:2. 16 TO ALERT THE VISUALLY IMPAIRED, MARK THE UPPER APPROACH AND THE LOWER TREAD OF EACH INTERIOR STAIR WITH A STRIP OF CLEARLY CONTRASTING COLOR AT LEAST 2" WIDE, PLACED PARALLEL TO AN NOT MORE THAN 1" FROM THE NOSE OF THE STEP OR LANDING. THE STRIP SHALL BE OF A MATERIAL THAT IS AT LEAST AS SLIP RESUSTANT AS THE OTHER TREADS OF THE STAIR. 17 CENTER ELECTRICAL RECEPTACLE OUTLETS NOT LESS THAN 15" ABOVE THE FLOOR OR WORKING PLATFORM. 1 COMPLY WITH LOCAL, STATE AND FEDERAL CODES AND REGULATIONS PERTAINING TO SAFETY OF PERSONS, PROPERTY AND ENVIRONMENTAL PROTECTION. 2 PROVIDE AND MAINTAIN MARRICADES, LIGHTING, AND GUARDRAILS AS REQUIRED BY APPLICABLE CODES AND REGULATIONS TO PROTECT OCCUPANTS OF BUILDING AND WORKS. 3 ERECT AND MAINTAIN DUSTPROOF PARTITIONS AS REQUIRED TO PREVENT SPREAD OF DUST, FUMES, AND SOME, ETC. TO OTHER PARTS OF THE BUILDING. ON COMPLETION, REMOVE PARTITIONS AND REPAIR DAMAGED SURFACES TO MATCH ADJACENT SURFACES. 4 IF DEMOLITION IS PREFORMED IN EXCESS OF THAT REQUIRED, RESTORE EFFECTED AREAS AT NO COST TO THE OWNERS. 5 REMOVE FROM SITE DAILY AND LEGALLY DISPOSE OF REFUSE, DEBRIS, RUBBISH, AND OTHER MATERIALS RESULTING FROM DEMOLITION OPERATIONS. 6 REMOVE DESIGNATED PARTITIONS, COMPONENTS, BUILDING EQUIPMENT, AND FIXTURES AS REQUIRED FOR NEW WORK. 7 REMOVE ABANDONED HVAC EQUIPMENT, INCLUDING DUCT WORK. 8 REMOVE ABANDONED ELECTRICAL, TELEPHONE AND DATA CABLING AND DEVICES, UNLESS OTHERWISE NOTED. 9 REMOVE EXISTING FLOOR FINISHES AND PREPARE SUBFLOOR AS REQUIRED FOR NEW FLOOR FINISHES. DEMOLITION NOTES Issue #Issue Date Issue Description 1 12/07/2015 ISSUE FOR 100% CD Assembly Door Frame WidthTypeLocationNo.Height Thickness Assembly Material Finish Head Jamb Sill Material Finish Fire Rating Hardware Set Remarks Details B101 ALUM/GLASS ---11/A12.00 -- ALUMINUM - -- #01A --3'-0"24 HOUR VESTIBULE 8'-4" V.I.F. - QTY DESCRIPTION MODEL FINISH MFR GROUP 1A - VESTIBULE AIRLOCK CENTER HUNG FLOOR CLOSER H100F (TOP) W/KEY CYLINDER 1 EA * PANIC DEVICE / PULL1 EA 630 BLU 1 EA BY DOOR MANUFACTURERPATCH FITTINGS1 SET 80-133MTSE CYL, AR CAM1 EA BTS75V BF/A-H - 90 HO 626 DRM 626 SCH 80-037SFIC EV B CORE ONLY 626 SCH FLOOR CLOSER PLATE COVER1 EA 7510 626 DRM FLOOR CLOSER SPINDLE1 EA CRL9040S3 CRL 1 EA ESK-1ELECTRIC STRIKE 626 BLU *Alternate Hardware G.C. to confirm with architect prior to ordering OVERHEAD CONCEALED CLOSER1 EA RTS88 BFI 626 DRM 10"1/2" TEMPERED UNIT GLASS FRAMELESS TYPE B Gensler One Beacon Street Third Floor Boston MA 02108 Tel: 617.619.5700 Fax: 617.619.5701 © 2015 Gensler Scale Description Project Number Project Name Seal/Signature NOT TO SCALE KEY NOTES GENERAL NOTES \\gensler.ad\Projects\RevitUserModels\19683\2015_BOA_Northampton SGVD_2014_19683.rvtA00.20 PARTITION TYPES, DOOR, HARDWARE & FINISH SCHEDULES 11.6561.057 SLIDING GLASS VESTIBULE DOOR REPLACEMENT 144 Main Street Northampton, MA 01060 SCALE: 12" = 1'-0" DOOR SCHEDULE 4 A. COORDINATE ALL HARDWARE WITH DOOR SWING. CLOSERS TO BE ON INTERIOR OF ALL ROOMS. IF NO WALL IS PROVIDED WHERE A WALL STOP HAS BEEN SPECIFIED, SUBMIT OVERHEAD STOP WITH HARDWARE SUBMITTAL. ALL SERCURITY HARDWARE TO BE LOCATED SO THE INTERIOR ROOM OR SPACE IS SECURE, U.N.O. B. ALL HARDWARE FINISH TO MATCH EXISTING, U.N.O. WHERE MULTIPLE FINISHES EXIST, NOTIFY ARCHITECT IMMEDIATELY AND CONFIRM FINAL FINISH SELECTION BEFORE ORDERING. C. WHERE NEW HARDWARE IS TO BE INSTALLED ON EXISTING DOORS, CONFIRM ALL SPECIFIED HARDWARE IS COMPATIBLE WITH EACH DOOR TYPE. NOTIFY ARCHITECT OF ALL CONFLICTS BEFORE ORDERING. SCALE: 12" = 1'-0" HARDWARE SCHEDULE 3 SCALE: 1/2" = 1'-0" DOOR TYPES 2 Issue #Issue Date Issue Description 1 12/07/2015 ISSUE FOR 100% CD 2'-6"4'-0"ACCESSIBLE ENTRANCE ACCESSIBLE PATHWAY ACCESSIBLE PATHWAY ACCESSIBLE PATHWAY ACCESSIBLE PATHWAY X IS THE 1'-0" MINIMUM HANDRAIL EXTENTION REQUIRED AT EACH TOP RISER Y IS THE MINIMUM HANDRAIL EXTENTION OF 1'-0" PLUS THE WIDTH OF ONE TREAD THAT IS REQUIRED AT EACH BOTTOM RISER. NOTE CONTINUED: SIGNS TO MEET ALL APPLICABLE 2010 FEDERAL ADA REQUIREMENTS. GRADE 2 BRAILLE BELOW SYMBOL5'-0" TO FINISH FLOORCOUPON BOOTH CL NOTE: .125 PHOTOPOLYMER SIGN PANEL WITH 1/4" RADIUS CORNERS. ADHERE TO WALL WITH VHB. 1/32" RAISED LETTERS AND GRAPHIC. WHITE FIGURE AND BLUE BACKGROUND. THE BLUE SHALL BE EQUAL TO COLOR NO. 15090 IN FEDERAL STANDARD 595B IN MATTE FINISH. NOTE CONTINUED: SIGNS TO MEET ALL APPLICABLE 2010 FEDERAL ADA REQUIREMENTS. GRADE 2 BRAILLE BELOW SYMBOL5'-0" TO FINISH FLOORENTRANCE CL NOTE: .125 PHOTOPOLYMER SIGN PANEL WITH 1/4" RADIUS CORNERS. ADHERE TO WALL WITH VHB. 1/32" RAISED LETTERS AND GRAPHIC. WHITE FIGURE AND BLUE BACKGROUND. THE BLUE SHALL BE EQUAL TO COLOR NO. 15090 IN FEDERAL STANDARD 595B IN MATTE FINISH. AT TELLER LINE, SET SIGN 1" FROM TOP OF MILLWORK. AT DOORS, SIGNS SHALL BE LOCATED ON THE DOOR, ADJACENT TO THE LATCH SIDE NOTE: VINYL DECAL WHITE FIGURE AND BLUE BACKGROUND. THE BLUE SHALL BE EQUAL TO COLOR NO. 15090 IN FEDERAL STANDARD 595B IN MATTE FINISH. CL 5'-0" TO FINISH FLOORCLEAR FLOOR SPACE EQUIPMENT PERMITTED IN SHADED AREA 2'-3" MIN.9" MIN.3'-0" MAX1'-5" TO 1'-7"2'-6" MIN.4'-0" MIN. 1'-5" TO 1'-7" 2'-0" MAX. KNEE CLEARANCE 8" MIN. 6" MAX TOE CLEARANCE 1/4 " MAX2 11/4" TO 1/2 "Lobby 4" MAX.HIGHER THAN 2'-3"2'-3" OR BELOWANY AMOUNT CLEAR WIDTH 6'-8" MIN.CLEAR FLOOR SPACE INSULATE HOT WATER PIPES AND DRAIN TO PREVENT CONTACT LINE OF REQUIRED CLEARANCE MIRROR 3'-4" MAX. TO REFLECTING SURFACE2'-10" MAX.2'-5" MIN.2'-3" MIN.1'-5" MIN. DEPTH 9" MIN.1'-5" MIN.2'-6" MIN.4'-0" MIN. 1'-7" MAX. KNEE CLEARANCE 8" MIN. 6" MAX TOE CLEARANCE ATM, DISPLAY FEATURES AND REACHIBILITY MUST CONFORM TO CBC AND ADA REQUIREMENTS. 4'-0"FORWARD REACH RANGEALLOWABLE AREAOF OPERATION1'-3" MIN.XLINE OF REQUIREDATM 2'-6"4'-0" CLEARANCE NOTE: Y= 4'-0" MIN.; NOTE: X =3'-0" MIN. IF Y=5'-0"; NOTE: X = 1'-0" IF DOOR HAS BOTH HAS A CLOSER 4'-0" MIN. 4'-0" MIN. Y=4'-0" MIN. IF DOOR NOTE: Y= 3'-6" MIN.;Y2'-0" HAS A CLOSER Y=4'-0" MIN. IF DOOR NOTE: Y= 3'-6" MIN.; Y= 4'-6" MIN. IF DOOR HAS A CLOSER YX= 3'-6" MIN. IF Y=4'-6".Y2'-0" A CLOSER AND A LATCH4'-0"X X Y4'-0"3'-0" MIN. 10" MAX. 2'-8" MIN. 2'-6"1'-3" MINFORWARD REACH RANGE4'-0"SIDE REACH RANGE4'-6"10" 2'-6" 4'-0"1'-3" MIN.4'-0"2'-0" MAX. DEPTHFOR MIN. CLEARANCE2'-6"TO TOP OF F.E.C. HANDLE4'-0"3'-2" 4'-0"6'-8"5'-0"CLUSTER - SEE PLAN PLATES FOR MORE THAN ONE DEVICE OF THE SAME SCHED. DOOR HARDWARE USE GANG-TYPE COVER CLUSTER. FOR QUANTITY OF EACH 6" TYPE. AUDIBLE/VISIBLE STROBE CARD READER, (ETC.) EGRESS BUTTON, LOCATION FOR: LIGHT SWITCH, DIMMERS, ABOVE DIMMERS) (DO NOT LOCATE DIRECTLY THERMOSTAT LOCATION DOOR FRAME FIRE EXTINGUISHER AND/OR HOSE CABINET HOLD UP LIGHT 4 1/2" REQ. ADA SIGNAGE ON 9" BEYOND DOOR SWING CENTERED ON WALL ON INTERIOR OF ROOM ON EXTERIOR OF ROOM TO BOTTOM OF FIXTUREY NOTE: X = 48" IF Y<10" X=46" IF 10"<Y<24" A A 1'-0" MIN Y 1'-0" X LESS THAN 2'-3"LESS THAN 2'-3"NOTE: ALL DIMENSIONS TO CENTER LINE OF DEVICES. SEE PLANS FOR SPECIFIC LOCATIONS. A B C E ALL CHARACTERS AND SYMBOLS TO BE WHITE ON A BLUE BACKGROUND, TYP. (ALL FINISHES TO BE NON-GLARE) D 5'-0"17"22"6"8"4"5/8"3/8"1/4"1"1"6"8"4"5/8"3/8"1/4"1"1"6"6"5'-0"1'-6" 4'-6" SINK OR VANITY SCALE: 1/2" = 1'-0"06 CLEARANCES SCALE: 1/2" = 1'-0"01 THRESHOLDS SCALE: FULL 02 REACH RANGES SCALE: 1/2" = 1'-0"04DRINKING FOUNTAIN SCALE: 1/2" = 1'-0"07 PROTRUDING OBJECTS SCALE: 1/4" = 1'-0"05HANDRAIL EXTENSIONS SCALE: 1/2" = 1'-0"10 ATM CLEARANCES SCALE: 1/2" = 1'-0"09 TYPICAL MOUNTING HEIGHTS SCALE: NTS 08 ACCESSIBLE SIGNAGE SCALE: 1/4" = 1'-0"11 WAYFINDING SIGNAGE SCALE: N.T.S.03 DIRECTIONAL SIGNAGE SCALE: 1/2" = 1'-0"13 ATM SIDE APPROACH SCALE: NTS 12 Gensler One Beacon Street Third Floor Boston MA 02108 Tel: 617.619.5700 Fax: 617.619.5701 © 2015 Gensler Scale Description Project Number Project Name Seal/Signature 12" = 1'-0"\\gensler.ad\Projects\RevitUserModels\19683\2015_BOA_Northampton SGVD_2014_19683.rvtA00.40 TYPICAL ADA INFORMATION 11.6561.057 SLIDING GLASS VESTIBULE DOOR REPLACEMENT 144 Main Street Northampton, MA 01060 Issue #Issue Date Issue Description 1 12/07/2015 ISSUE FOR 100% CD 24 HOUR VESTIBULE 101 ENTRY VESTIBULE 100 ATM ROOM 102 1 3 4 5 6 6 6 2 2 7 LOBBY 103 24 HOUR VESTIBULE 101 ENTRY VESTIBULE 100 ATM ROOM 102 OPEN TO ABOVE 10 10 LOBBY 103 9 1 EXISTING 9' - 0" 9' - 0" EXISTING 11 E 8 E EE E E E E E E EE E E E X'-X" ST T SD D MOTION SENSOR DENOTES EXISTING, RELOCATED FIXTURE DENOTES EXISTING TO REMAINE R LINEAR DIFFUSER DIMENSION OF CEILING ABOVE FINISH FLOOR CEILING HEIGHT CHANGE PROJECTION SCREEN SECURITY CAMERA SUPPLY AIR LIGHT SWITCH RETURN AIR DIMMER SWITCH THERMOSTAT ACCESS DOOR RECESSED WALL WASHER SURFACE MOUNTED LIGHT FIXTURE TRACK LIGHTING WALL SCONCE RECESSED DOWNLIGHT CEILING MOUNTED EXIT SIGN SMOKE DETECTOR SPEAKER EXHAUST FAN UNDER CABINET FLUORESCENT FIXTURE FLUORESCENT STRIP FIXTURE ACOUSTICAL CEILING AND GRID FLUORESCENT LIGHT FIXTURE EXISTING TO BE REMOVED MAIN RUNNER REFLECTED CEILING STROBE FIRE SPRINKLER CIRCULAR DIFFUSER ADJUSTABLE DOWNLIGHT FLUORESCENT PENDANT FIXTURE WALL MOUNTED EXIT SIGN MS EQUIPMENTXX Gensler One Beacon Street Third Floor Boston MA 02108 Tel: 617.619.5700 Fax: 617.619.5701 Ref. North © 2015 Gensler Scale Description Project Number Project Name Seal/Signature KEY NOTES GENERAL NOTES As indicated \\gensler.ad\Projects\RevitUserModels\19683\2015_BOA_Northampton SGVD_2014_19683.rvtA01.01 DEMOLITION PLAN AND DEMOLITION REFLECTED CEILING PLAN 11.6561.057 SLIDING GLASS VESTIBULE DOOR REPLACEMENT 144 Main Street Northampton, MA 01060 A. COMPLY WITH APPLICABLE LOCAL, STATE AND FEDERAL CODES AND REGULATIONS PERTAINING TO SAFETY OF PERSONS, PROPERTY AND ENVIRONMENTAL PROTECTION. B. PROVIDE AND MAINTAIN BARRICADES, LIGHTING, AND GUARDRAILS AS REQUIRED BY APPLICABLE CODES AND REGULATIONS TO PROTECT OCCUPANTS OF BUILDING AND WORKERS. C. ERECT AND MAINTAIN DUSTPROOF PARTITIONS AS REQUIRED TO PREVENT SPREAD OF DUST, FUMES, AND SMOKE, ETC. TO OTHER PARTS OF THE BUILDING. ON COMPLETION, REMOVE PARTITIONS AND REPAIR DAMAGED SURFACES TO MATCH ADJACENT SURFACES. D. IF DEMOLITION IS PERFORMED IN EXCESS OF THAT REQUIRED, RESTORE EFFECTED AREAS AT NO COST TO THE OWNER. E. REMOVE FROM SITE DAILY AND LEGALLY DISPOSE OF REFUSE, DEBRIS, RUBBISH, AND OTHER MATERIALS RESULTING FROM DEMOLITION OPERATIONS. F. REMOVE DESIGNATED PARTITIONS, COMPONENTS, BUILDING EQUIPMENT, AND FIXTURES AS REQUIRED FOR NEW WORK. G. REMOVE ABANDONED HVAC EQUIPMENT, INCLUDING DUCT WORK. H. REMOVE ABANDONED ELECTRICAL, CABLING AND DEVICES. I. ALL FURNITURE AFFECTED BY DEMOLITION AND NEW CONSTRUCTION LAYOUT IS TO BE RELOCATED. NO FURNITURE IS TO BE DISPOSED, U.N.O. COORDINATE FINAL RELOCATION WITH OWNER AND SITE MANAGER. J. ALL SECURITY DEVICES AND SYSTEMS TO REMAIN INTACT DURING ALL PHASES OF WORK. ANY MODIFICATIONS NEEDED DUE TO AREA OF DEMOLITION AND NEW CONSTRUCTION LAYOUT TO BE PERFORMED BY OWNER'S SECURITY VENDOR AND TO BE COORDINATED WITH OWNER PRIOR TO DEMOLITION. K. ALL LIGHT LENSES IN AREA OF WORK ARE REQUIRED TO BE CLEANED, REGARDLESS IF FIXTURE IS NEW, RELOCATED OR REMAINING IN THE EXISTING LOCATION. L. GC IS REQUIRED TO PERFORM INTERNAL REVIEW PRIOR TO ARCHITECT/OWNER PUNCH LIST WALK. M. NO DEVIATIONS FROM CONSTRUCTION DOCUMENTS WITHOUT PROPER RFI. SCALE: 1/2" = 1'-0" DEMOLITION PLAN 1 SCALE: 1/2" = 1'-0" DEMOLITION REFLECTED CEILING PLAN 7 SCALE: 12" = 1'-0" GRAPHIC SYMBOLS 3 1 5 3 REMOVE SLIDING DOOR SYSTEM. PATCH AND PREPARE SURFACE AS NECESSARY FOR NEW VESTIBULE AIRLOCK INSTALLATION. REMOVE EXISTING SLIDING GLASS DOOR TRACK AND THRESHOLD AS NECESSARY FOR INSTALLATION OF NEW VESTIBULE AIRLOCK SYSTEM. EXISTING CEILING, LIGHTING AND HVAC TO REMAIN, U.O.N. PATCH AND REPAIR AS NECESSARY. EXISTING SECURITY CAMERA TO REMAIN. (OWNER TO COORDINATE WITH SECURITY VENDOR) 10 8 9 REMOVE EXISTING SLIDING GLASS VESTIBULE CEILING TRACK. PATCH AND REPAIR CEILING AS NECESSARY. REMOVE EXISTING WALL MOUNTED CHECK DESK. PATCH AND REPAIR WALL AS NECESSARY. MATCH EXISTING FINISHES. REMOVE EXISTING WALK-OFF MAT THROUGHOUT 24 HOUR VESTIBULE. PATCH AND REPAIR FLOOR TO RECEIVE NEW FLOORING. REFER TO CONSTRUCTION PLAN FOR EXTENT OF WORK. 6 REMOVE PORTION OF TILE FLOORING TO GROUT LINE AS INDICATED BY HATCH. 4 2 REMOVE FLIPPER DOOR. PATCH AND REPAIR WOOD MOLDING AS NECESSARY. MATCH EXISTING FINISHES. EXISTING VESTIBULE CHECK DESK TO REMAIN. 7 EXISTING DRYWALL SOFFIT TO REMAIN. PATCH AND REPAIR AS NECESSARY. MATCH EXISTING FINISHES. 11 Issue #Issue Date Issue Description 1 12/07/2015 ISSUE FOR 100% CD UP ENTRY VESTIBULE 100 24 HOUR VESTIBULE 101 ATM ROOM 102 WM-3 101 V .I.F. V.I.F. 5' - 9 1/2"MIN. 3' - 0" 1 2 2 3 4 4 A12.00 4 A12.00 3 A12.00 7 135.00° WM-3 OPEN TO ABOVE 7 6 6 1 5 LOBBY 103 24 HOUR VESTIBULE 101 ENTRY VESTIBULE 100 ATM ROOM 102 9' - 0" 9' - 0" EXISTING EXISTING X'-X" ST T SD D MOTION SENSOR DENOTES EXISTING, RELOCATED FIXTURE DENOTES EXISTING TO REMAINE R LINEAR DIFFUSER DIMENSION OF CEILING ABOVE FINISH FLOOR CEILING HEIGHT CHANGE PROJECTION SCREEN SECURITY CAMERA SUPPLY AIR LIGHT SWITCH RETURN AIR DIMMER SWITCH THERMOSTAT ACCESS DOOR RECESSED WALL WASHER SURFACE MOUNTED LIGHT FIXTURE TRACK LIGHTING WALL SCONCE RECESSED DOWNLIGHT CEILING MOUNTED EXIT SIGN SMOKE DETECTOR SPEAKER EXHAUST FAN UNDER CABINET FLUORESCENT FIXTURE FLUORESCENT STRIP FIXTURE ACOUSTICAL CEILING AND GRID FLUORESCENT LIGHT FIXTURE EXISTING TO BE REMOVED MAIN RUNNER REFLECTED CEILING STROBE FIRE SPRINKLER CIRCULAR DIFFUSER ADJUSTABLE DOWNLIGHT FLUORESCENT PENDANT FIXTURE WALL MOUNTED EXIT SIGN MS EQUIPMENTXX Gensler One Beacon Street Third Floor Boston MA 02108 Tel: 617.619.5700 Fax: 617.619.5701 Ref. North © 2015 Gensler Scale Description Project Number Project Name Seal/Signature KEY NOTES GENERAL NOTES As indicated \\gensler.ad\Projects\RevitUserModels\19683\2015_BOA_Northampton SGVD_2014_19683.rvtA02.01 CONSTRUCTION PLAN AND REFLECTED CEILING PLAN 11.6561.057 SLIDING GLASS VESTIBULE DOOR REPLACEMENT 144 Main Street Northampton, MA 01060 A. REPAIR EXISTING SURFACES TO REMAIN AS REQUIRED FOR APPLICATION OF NEW FINISHES. B. WHERE EXISTING ACCESS PANELS CONFLICT WITH CONSTRUCTION, RELOCATE PANELS TO ALIGN WITH AND FIT WITHIN NEW CONSTRUCTION. C. CONTRACTOR SHALL PROVIDE BLOCKING FOR ALL EQUIPMENT, FIXTURES, MILLWORK & ACCESSORIES MOUNTED ON WALL. D. CONTRACTOR SHALL PROVIDE COLOR SAMPLES FOR ALL FINISHES & P-LAM TO OWNER & ARCHITECT PRIOR TO ORDERING AND INSTALLATION. E. DO NOT SCALE DRAWINGS. WRITTEN DIMENSIONS GOVERN. IN CASE OF CONFLICT, CONSULT THE ARCHITECT. F. PARTITIONS ARE DIMENSIONED FROM FINISH FACE TO FINISH FACE UNLESS OTHERWISE NOTED. MAINTAIN DIMENSIONS MARKED AS "CLEAR". ALLOW FOR THICKNESS OF FINISHES. G. G.C. SHALL PROVIDE ALL WORK RELATED TO ENGINEERING TO INCLUDE, BUT NOT LIMITED TO: MECHANICAL, ELECTRICAL, FIRE PROTECTION & LIFE SAFETY. G.C. SHALL PROVIDE DESIGN DRAWINGS, PERMITS & INSTALLATION OF SYSTEMS ON A DESIGN BUILD BASIS. H. RELOCATE EXISTING FIXTURES ON WALLS TO BE REMOVED TO NEW PARTITION. REFER TO SHEET A00.40 FOR TYPICAL MOUNTING HEIGHTS. I. PROVIDE SUBMITTALS FOR DOOR HARDWARE. J. ROLL-DOWN GRILLE CONTROLS TO BE 48" AFF MAX. SCALE: 1/2" = 1'-0" CONSTRUCTION PLAN 1 4 6 EXISTING CEILING, LIGHTING AND HVAC TO REMAIN. PATCH AND REPAIR TO MATCH EXISTING AS NECESSARY. PATCH AND REPAIR FLOOR AND WALL FINISHES AS NECESSARY. SCALE: 1/2" = 1'-0" REFLECTED CEILING PLAN 7 SCALE: 12" = 1'-0" GRAPHIC SYMBOLS 3 2 NEW INFILL WALL TO BE FINISHED TO MATCH EXISTING. 1 NEW VESTIBULE AIRLOCK MONOLITHIC TEMPERED GLAZING SYSTEM WITH SINGLE DOOR. REFER TO 12.00 SERIES FOR DRAWINGS AND DETAILS. 3 PROVIDE NEW WM-03, WALK-OFF MAT FLOOR FINISH THROUGHOUT 24 HOUR VESTIBULE (ABRASIVE ACTION / TANDUS GROUP). 7 PROVIDE NEW EXIT SIGN. 5 PATCH AND REPAIR DRYWALL SOFFIT AS NECESSARY. MATCH EXISTING FINISHES. Issue #Issue Date Issue Description 1 12/07/2015 ISSUE FOR 100% CD A12.00 3 A12.00 7 101 24 HOUR VESTIBULE 101 LOBBY 103 V .I.F. 6' - 8 1/2" V.I.F. 5' - 9 1/2"EQ.EQ.1 1 6 135.00° A12.00 2 A12.00 14 SIM. A12.00 10 2' - 6"5' - 0"V.I.F.9' - 0"4 2 5 8 EQ.EQ. 15 A12.00 14 A12.00 10 A12.00 SIM. A12.00 2 2' - 6"5' - 0"V.I.F.9' - 0"1 3 2 4 7 5 11 A12.00 15 A12.00 10 A12.00 SIM. A12.00 6 V.I.F. 3' - 5" TOP TRACK SIDELITE RAIL SIDELITE CLIP (2X2) SIDELITE CLIP (2X2) GLAZING GASKET (BLACK) GLAZING GASKET (BLACK) EXISTING CEILING TO REMAIN LINE OF FLOOR TILE MECHANICALLY FASTEN SIDELIGHT RAIL TRACK AS RECOMMENDED BY A/E 2" 23"V.I.F.2" 1/4"4" 23"2"2" G.C. TO PROVIDE AND ENGINEER STRUCTURAL SUPPORT AT TOP RAIL OF GLASS AS NEEDED OR REQUIRED PER MANUFACTURERS' REQUIREMENTS. DOOR RAIL RECESSED FLOOR CLOSER LINE OF FLOOR TILE LINE OF DOOR PATCH BEYOND PANIC HARDWARE INTERIOR LOBBYVESTIBULE DOOR STOP/STRIKE CYLINDER TOP TRACK GLAZING GASKET (BLACK) 1/2" X 1"X 1/2" METAL U-CHANNEL GASKET 2" 6"2" 10 1/2" 1/4"10"2" EXISTING CEILING TO REMAIN V.I.F.G.C. TO PROVIDE AND ENGINEER STRUCTURAL SUPPORT AT TOP RAIL OF GLASS AS NEEDED OR REQUIRED PER MANUFACTURERS' REQUIREMENTS. MANUFACTURER'S CUSTOM COVER PLATE AT PIVOT. ATTACHED W/ (2) OVAL HEAD PHILLIPS SCREWS 2"X2" SQUARE SIDELITE CLIP 1/4 2" 1/2" GYP. BOARD BLOCKING PLYWOOD 1" X 1" WALL CHANNEL 3/8" GYP. BOARD 3/4 1"1" x 1" RED SQUARES IN: ORACAL SERIES 8300 (032) TRANSPARENT VINYL (3MIL.) APPLIED TO SECOND SURFACE DISTRACTION STRIPES IN: 3M DUSTED CRYSTAL VINYL APPLIED TO SECOND SURFACE CUT BETWEEN RED SQUARES EDGE OF GLASS PANEL NOTE TO A/E DISTRACTION STRIPES BY SIGNAGE VENDOR 1" VARIES EQ.1' - 3"1' - 3" VARIES EQ. 1/8" 1/4" 1/4" 1/4" 1/8" 30" 60"MITERED SIDELITE RAIL BEYOND SIDELITE RAIL GASKET BEYOND 135° MALL CLAMP (CRL MFC26) Gensler One Beacon Street Third Floor Boston MA 02108 Tel: 617.619.5700 Fax: 617.619.5701 © 2015 Gensler Scale Description Project Number Project Name Seal/Signature NOTE: EVERY KEY NOTE MAY NOT APPEAR ON THIS PAGE KEY NOTES GENERAL NOTES As indicated \\gensler.ad\Projects\RevitUserModels\19683\2015_BOA_Northampton SGVD_2014_19683.rvtA12.00 AIRLOCK VESTIBULE DETAILS 11.6561.057 SLIDING GLASS VESTIBULE DOOR REPLACEMENT 144 Main Street Northampton, MA 01060 1 2" X 6" ALUMINUM RECTANGLE TUBE FRAMED ENTRY. 2 3 4 5 6 NEW 5/8" MONOLITHIC TEMPERED VESTIBULE AIRLOCK SYSTEM. DISTRACTION MARKERS BY SIGN VENDOR. TOP DOOR PATCH FITTING; CRL #PH20AA, PIVOT INSERT; #1NT303. 7 A. REFER TO A00.10 FOR GENERAL NOTES. B. REFER TO A00.40 FOR TYPICAL MOUNTING HEIGHTS. C. CONTRACTOR SHALL PROVIDE BLOCKING FOR ALL EQUIPMENT/ACCESSORIES MOUNT ON WALL. D. ALL SECURITY DEVICES AND SYSTEMS TO REMAIN INTACT DURING ALL PHASES OF WORK. ANY MODIFICATIONS NEEDED DUE TO AREA OF DEMOLITION AND NEW CONSTRUCTION LAYOUT TO BE PERFORMED BY OWNER'S SECURITY VENDOR AND TO BE COORDINATED WITH OWNER PRIOR TO DEMOLITION. E. G.C. SHALL PROVIDE ALL WORK RELATED TO ENGINEERING TO INCLUDE, BUT NOT LIMITED TO: MECHANICAL, ELECTRICAL, FIRE PROTECTION & LIFE SAFETY. G.C. SHALL PROVIDE DESIGN DRAWINGS, PERMITS & INSTALLATION OF SYSTEMS ON A DESIGN BUILD BASIS. SCALE: 1/2" = 1'-0" AIRLOCK VESTIBULE ENLARGED PLAN 4 SCALE: 1/2" = 1'-0" AIRLOCK VESTIBULE ELEVATION 3SCALE: 1/2" = 1'-0" AIRLOCK VESTIBULE ELEVATION 7 BOTTOM DOOR RAIL; CRL #DR10SSA12S. TOP SIDELITE RAIL; CRL #SR2SSA34SL WITH SATIN ANODIZED FINISH. BOTTOM SIDELITE RAIL; CRL #SR4SSA34SL WITH SATIN ANODIZED FINISH. 2 X 2 SQUARE MALL FRONT CLAMP; CRL #MFC19 WITH BRUSHED STAINLESS STEEL FINISH. 8 SCALE: 3" = 1'-0" SIDELITE SECTION 15 SCALE: 3" = 1'-0" DOOR SECTION 11 SCALE: 12" = 1'-0" SIDECLIP DETAIL 2SCALE: 12" = 1'-0" WALL TERMINATION DETAIL 14 SCALE: 1 1/2" = 1'-0" DISTRACTION MARKERS 6SCALE: 12" = 1'-0" DETAIL AT CORNER 10 Issue #Issue Date Issue Description 1 12/07/2015 ISSUE FOR 100% CD Gensler One Beacon Street Third Floor Boston MA 02108 Tel: 617.619.5700 Fax: 617.619.5701 © 2015 Gensler Scale Description Project Number Project Name Seal/Signature KEY NOTES \\gensler.ad\Projects\RevitUserModels\19683\2015_BOA_Northampton SGVD_2014_19683.rvtA12.20 EXISTING CONDITION PHOTOS 11.6561.057 SLIDING GLASS VESTIBULE DOOR REPLACEMENT 144 Main Street Northampton, MA 01060 24 HOUR VESTIBULE SCALE: AS NOTED 4 CEILING SCALE: AS NOTED 3 OVERALL VIEW OF 24 HOUR VESTIBULE. VIEW OF SLIDING GLASS VESTIBULE CEILING TRACK.VIEW OF SLIDING GLASS VESTIBULE CEILING TRACK.OVERALL VIEW OF CEILING. VIEW OF EXISTING SLIDING GLASS VESTIBULE DOOR TRACK AND ATMs. Issue #Issue Date Issue Description 1 12/07/2015 ISSUE FOR 100% CD OVERALL VIEW OF 24 HOUR VESTIBULE.VIEW OF EXISTING SLIDING GLASS VESTIBULE DOOR TRACK.