Loading...
23D-153 Groccia 8-28-174te_calcpackage01: Level Member Name Results Current Solution Comments 10' Header Passed 2 Piece(s) 1 3/4" x 11 7/8" 2.0E Microllam® LVL 12' 10" Header Passed 2 Piece(s) 1 3/4" x 11 7/8" 2.0E Microllam® LVL Groccia 8-28-17.4te JOB SUMMARY REPORT Forte v5.2, Design Engine: V6.6.0.14 8/28/2017 2:52:45 PM Page 1 of 3 Groccia 8-28-17.4te Forte Software Operator Brian Pedersen Ed Herrington, Inc. (860) 435-2561 brian.pedersen@herringtons.com Job Notes 2 piece(s) 1 3/4" x 11 7/8" 2.0E Microllam® LVL Bearing Loads to Supports (lbs) Supports Total Available Required Dead Floor Live Snow Total Accessories 1 - Trimmer - SPF 3.00"3.00"1.68"1550 1260 2368 5178 None 2 - Trimmer - SPF 3.00"3.00"1.68"1550 1260 2368 5178 None All locations are measured from the outside face of left support (or left cantilever end).All dimensions are horizontal.;Drawing is Conceptual Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) Member Reaction (lbs)4271 @ 0 1 8 7613 (3.00")Passed (56%)--1.0 D + 0.75 L + 0.75 S (All Spans) Shear (lbs)3262 @ 1 2 14 9081 Passed (36%)1.15 1.0 D + 0.75 L + 0.75 S (All Spans) Moment (Ft-lbs)10683 @ 5 3 0 20525 Passed (52%)1.15 1.0 D + 0.75 L + 0.75 S (All Spans) Live Load Defl. (in)0.151 @ 5 3 0 0.256 Passed (L/817)--1.0 D + 0.75 L + 0.75 S (All Spans) Total Load Defl. (in)0.236 @ 5 3 0 0.512 Passed (L/520)--1.0 D + 0.75 L + 0.75 S (All Spans) System : Wall Member Type : Header Building Use : Residential Building Code : IBC 2012 Design Methodology : ASD •Deflection criteria: LL (L/480) and TL (L/240). •Top Edge Bracing (Lu): Top compression edge must be braced at 10 6 0 o/c unless detailed otherwise. •Bottom Edge Bracing (Lu): Bottom compression edge must be braced at 10 6 0 o/c unless detailed otherwise. Level, 10' HeaderMEMBER REPORT PASSED Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties related to the software. Refer to current Weyerhaeuser literature for installation details. (www.woodbywy.com) Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is compatible with the overall project. Products manufactured at Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC ES under technical reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports refer to http://www.woodbywy.com/services/s_CodeReports.aspx. The product application, input design loads, dimensions and support information have been provided by Forte Software Operator Weyerhaeuser Notes Tributary Dead Floor Live Snow Loads Location (Side)Width (0.90)(1.00)(1.15)Comments 0 - Self Weight (PLF)0 0 0 to 10 6 0 N/A 12.1 1 - Uniform (PSF)0 0 0 to 10 6 0 4 0 0 15.5 -41.0 Residential - Living Areas 2 - Uniform (PSF)0 0 0 to 10 6 0 6 0 0 15.0 40.0 - 3 - Uniform (PSF)0 0 0 to 10 6 0 7 0 0 18.7 -41.0 Forte v5.2, Design Engine: V6.6.0.14 8/28/2017 2:52:45 PM Page 2 of 3 Groccia 8-28-17.4te Forte Software Operator Brian Pedersen Ed Herrington, Inc. (860) 435-2561 brian.pedersen@herringtons.com Job Notes 2 piece(s) 1 3/4" x 11 7/8" 2.0E Microllam® LVL Bearing Loads to Supports (lbs) Supports Total Available Required Dead Floor Live Snow Total Accessories 1 - Trimmer - SPF 3.00"3.00"1.52"1666 267 2187 4120 None 2 - Trimmer - SPF 3.00"3.00"1.52"1666 267 2187 4120 None All locations are measured from the outside face of left support (or left cantilever end).All dimensions are horizontal.;Drawing is Conceptual Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) Member Reaction (lbs)3853 @ 0 1 8 7613 (3.00")Passed (51%)--1.0 D + 1.0 S (All Spans) Shear (lbs)3156 @ 1 2 14 9081 Passed (35%)1.15 1.0 D + 1.0 S (All Spans) Moment (Ft-lbs)12513 @ 6 8 0 20525 Passed (61%)1.15 1.0 D + 1.0 S (All Spans) Live Load Defl. (in)0.241 @ 6 8 0 0.327 Passed (L/652)--1.0 D + 1.0 S (All Spans) Total Load Defl. (in)0.429 @ 6 8 0 0.654 Passed (L/366)--1.0 D + 1.0 S (All Spans) System : Wall Member Type : Header Building Use : Residential Building Code : IBC 2012 Design Methodology : ASD •Deflection criteria: LL (L/480) and TL (L/240). •Top Edge Bracing (Lu): Top compression edge must be braced at 11 2 0 o/c unless detailed otherwise. •Bottom Edge Bracing (Lu): Bottom compression edge must be braced at 13 4 0 o/c unless detailed otherwise. Level, 12' 10" HeaderMEMBER REPORT PASSED Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties related to the software. Refer to current Weyerhaeuser literature for installation details. (www.woodbywy.com) Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is compatible with the overall project. Products manufactured at Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC ES under technical reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports refer to http://www.woodbywy.com/services/s_CodeReports.aspx. The product application, input design loads, dimensions and support information have been provided by Forte Software Operator Weyerhaeuser Notes Tributary Dead Floor Live Snow Loads Location (Side)Width (0.90)(1.00)(1.15)Comments 0 - Self Weight (PLF)0 0 0 to 13 4 0 N/A 12.1 1 - Uniform (PSF)0 0 0 to 13 4 0 6 0 0 15.5 -41.0 Residential - Living Areas 2 - Uniform (PSF)0 0 0 to 13 4 0 1 0 0 15.0 40.0 - 3 - Tapered (PLF)0 0 0 to 6 8 0 N/A 80.0 to 120.0 --Gable Wall 4 - Tapered (PLF)6 8 0 to 13 4 0 N/A 120.0 to 80.0 --Gable Wall 5 - Uniform (PSF)0 0 0 to 13 4 0 2 0 0 15.0 -41.0 Forte v5.2, Design Engine: V6.6.0.14 8/28/2017 2:52:45 PM Page 3 of 3 Groccia 8-28-17.4te Forte Software Operator Brian Pedersen Ed Herrington, Inc. (860) 435-2561 brian.pedersen@herringtons.com Job Notes