Loading...
24D-294 CS 2nd floor Beam CalcCS Structure™ 2016.5.1 [Build 2] kmBeamEngine 2016.5.0.2 Materials Database 1555 ClarkRogerPark - Level 8 11- 8-16 2:34pm 1 of 2 All product names are trademarks of their respective owners Copyright (C) 2016 by Simpson Strong-Tie Company Inc. ALL RIGHTS RESERVED.**Passing is defined as when the member, floor joist, beam or girder, shown on this drawing meets applicable design criteria for Loads, Loading Conditions, and Spans listed on this sheet. The design must be reviewed by a qualified designer or design professional as required for approval. This design assumes product installation according to the manufacturer`s specifications. Doug Hodgins rk Miles Inc. 21 West St. West Hatfield Ma. Member Data Description: CalcG1 Member Type: Girder Application: Floor Comments:Top Lateral Bracing: Continuous Bottom Lateral Bracing: Continuous Standard Load: Moisture Condition: Dry Building Code: IBC/IRC Live Load: 0 PLF Deflection Criteria: L/360 live, L/240 total Dead Load: 0 PLF Deck Connection: Nailed Member Weight: 18.1 PLF Filename: C:\KMW\JOBS\ Other Loads Type (Description) Side Begin End Trib. Width Other Start End Dead Start End Category Replacement Uniform (PLF) Top 0' 0.00" 15' 8.75" 349 146 Live Replacement Uniform (PLF) Top 0' 0.00" 15' 8.75" 407 146 Live 1 2 3 4 4 3 0 7 6 0 3 11 12 15 8 12 Bearings and Reactions Input Min Gravity Gravity Location Type Material Length Required Reaction Uplift 1 0' 0.000" Wall SPF Plate (425psi) N/A 1.500" 1751# -304# 2 4' 3.000" Wall SPF Plate (425psi) N/A 3.295" 7352# -- 3 11' 9.000" Wall SPF Plate (425psi) N/A 3.250" 7252# -- 4 15' 8.750" Girder SPF Plate (425psi) N/A N/A 1563# -491# Maximum Load Case Reactions Used for applying point loads (or line loads) to carrying members Live Dead 1 1426# 326# 2 5250# 2101# 3 5193# 2059# 4 1321# 241# Design spans 4' 0.875" 7' 6.000" 3' 8.250" Product: 1-3/4x11-7/8 VERSA-LAM 2.0 3100 SP 3 ply PASSES DESIGN CHECKS Design assumes continuous lateral bracing along the top chord. Design assumes continuous lateral bracing along the bottom chord. Review gravity uplift reaction force of 305lbs at bearing 1 and ensure that the structure can resist appropriately. Review gravity uplift reaction force of 491lbs at bearing 4 and ensure that the structure can resist appropriately. Allowable Stress Design Actual Allowable Capacity Location Loading Positive Moment 3628.'# 33189.'# 10% 8' Even Spans D+L Negative Moment 4432.'# 33189.'# 13% 4.25' Adjacent 1 D+L Shear 3040.# 11845.# 25% 11' Adjacent 2 D+L TL Deflection 0.0197" 0.3750" L/999+ 8' Even Spans D+L LL Deflection 0.0149" 0.2500" L/999+ 8' Even Spans L Control: Shear DOLs: Live=100% Snow=115% Roof=125% Wind=160% Design assumes a repetitive member use increase in bending stress: 4 % Manufacturer's installation guide MUST be consulted for multi-ply connection details and alternatives Minimum bearing length requirements at hangared connections depend on the connection style and are not included in this design. CS Structure™ 2016.5.1 [Build 2] kmBeamEngine 2016.5.0.2 Materials Database 1555 ClarkRogerPark - Level 8 11- 8-16 2:34pm 2 of 2 All product names are trademarks of their respective owners Copyright (C) 2016 by Simpson Strong-Tie Company Inc. ALL RIGHTS RESERVED.**Passing is defined as when the member, floor joist, beam or girder, shown on this drawing meets applicable design criteria for Loads, Loading Conditions, and Spans listed on this sheet. The design must be reviewed by a qualified designer or design professional as required for approval. This design assumes product installation according to the manufacturer`s specifications. Doug Hodgins rk Miles Inc. 21 West St. West Hatfield Ma. Member Data Description: CalcG4 Member Type: Girder Application: Floor Comments:Top Lateral Bracing: Continuous Bottom Lateral Bracing: Continuous Standard Load: Moisture Condition: Dry Building Code: IBC/IRC Live Load: 0 PLF Deflection Criteria: L/360 live, L/240 total Dead Load: 0 PLF Deck Connection: Nailed Member Weight: 28.4 PLF Filename: C:\KMW\JOBS\ Other Loads Type (Description) Side Begin End Trib. Width Other Start End Dead Start End Category Replacement Uniform (PLF) Top 0' 0.00" 9' 4.00" -53 -13 Live Replacement Uniform (PLF) Top 0' 0.00" 9' 4.00" 40 13 Live Replacement Uniform (PLF) Top 0' 0.00" 15' 0.00" 27 7 Live Replacement Uniform (PLF) Top 0' 0.00" 15' 0.00" 667 0 Snow Replacement Uniform (PLF) Top 0' 0.00" 15' 0.00" 307 474 Live Point (LBS) Top 9' 4.00" 345 174 Live Point (LBS) Top 9' 4.00" 1363 271 Live 1 2 15 0 0 15 0 0 Bearings and Reactions Input Min Gravity Gravity Location Type Material Length Required Reaction Uplift 1 0' 0.000" Wall SPF Plate (425psi) N/A 3.409" 10140# -209# 2 15' 0.000" Wall SPF Plate (425psi) N/A 3.504" 10423# -- Maximum Load Case Reactions Used for applying point loads (or line loads) to carrying members Live Snow Dead 1 3333# 4887# 3976# 2 3623# 4887# 4041# Design spans 14' 7.750" Product: 1-3/4x14 VERSA-LAM 2.0 3100 SP 4 ply PASSES DESIGN CHECKS Minimum 3.41" bearing required at bearing # 1 Minimum 3.50" bearing required at bearing # 2 Design assumes continuous lateral bracing along the top chord. Design assumes continuous lateral bracing along the bottom chord. Allowable Stress Design Actual Allowable Capacity Location Loading Positive Moment 39425.'# 69451.'# 56% 8.23' Total Load D+0.75(L+S) Negative Moment 578.'# 60392.'# 0% 6.04' Total Load D+L Shear 8954.# 21413.# 41% 14.09' Total Load D+0.75(L+S) TL Deflection 0.4726" 0.7323" L/371 7.5' Total Load D+0.75(L+S) LL Deflection 0.2908" 0.4882" L/604 7.5' Total Load 0.75(L+S) Control: TL Deflection DOLs: Live=100% Snow=115% Roof=125% Wind=160% Design assumes a repetitive member use increase in bending stress: 4 % Manufacturer's installation guide MUST be consulted for multi-ply connection details and alternatives