Loading...
31B-051 135 King Signs 2017-07-27450 SFMulti-Purpose108891 SFCardio1041043 SFStrength106960 SFFree Weights10754 SFUnisex Restroom112292 SFGuest Lobby10163 SFMens ShowerRoom11064 SFWomens ShowerRoom109107 SFManager102195 SFMembers Lobby10396 SFTrainers105CARPET54 SFStorage113CARPET 4'-0" ROLLED RUBBERPLANKCARPETFLOOR TILE1011021081051041063' - 0"7' - 0"FLOOR TILECARPET FLRTILE12' - 6"3' - 6"101103A3.127' - 0"9' - 0"12' - 10"10' - 0"11' - 6"W.H.INSPIRATIONAL WALL7' - 0"RETAIL WALL8' - 0"EXISTING EGRESS DOORS SHALLRECEIVE PANIC HARDWARECONTINUE VESTIBULE FRAMING & G.W.B. TO UNDERSIDE OF DECK EXISTING ALUMINUM ENTRYDOOR TO RECEIVE ELECTRIC STRIKEPOWER SUPPLY & CARD READER BY OTHERSCLEAR FLOOR AREA7' - 0"MANIFESTO WALL7' - 0"1/4" MAPLE WALL PROTECTION TO 48" A.F.F. OR UNDERSIDE OF WINDOW SILL1x CLEAR MAPLE WINDOW SILL (TYPAT ALL WINDOW OPENINGS) AFLP COMMUNICATION'REQUIRED' PROVIDE 1X2 CLEARMAPLE CHAIR RAILAT TOP OF WALL PROTECTION (TYPICAL) 'AFIT NATION'GRAPHIC 6'-0" ROLL TURF708 SFFunctional114130 SFConference/Lounge11511111133111133CLOSET10710911069 SFVestibule111STEEL SUPPORT STRUCTURE 11'-2" A.F.F.20' - 8"21' - 9"10' - 8"FLOOR TILEFLRTILEFLRTILEFLRTILECONTRACTOR TO COORDINATE CUTTING & PATCHING OF ALL TRADES. MATCH EXISTING MATERIALS AS REQUIRED. CONTRACTOR TO COORDINATE KEYING SYSTEMS AND ALL HARDWARE FUNCTIONS WITH OWNER. CONTRACTOR TO COORDINATE THE INSTALLATION OF ALL ELECTRICAL, ALARM, SECURITY, DATA AND TELEPHONE LINES. CONCEAL ALL NEW UTILITIES IN FINISHED AREAS AS REQUIRED. TELEPHONES TO BE FURNISHED AND INSTALLED BY OWNER. LIFE SAFETY SYSTEMS SHALL BE INSTALLED AS REQUIRED, PER N.F.P.A., AND LOCAL REGULATIONS. CONTRACTOR TO COORDINATE ALL DELIVERY SCHEDULES AND LOCATIONS FOR ALL OWNER FURNISHED ITEMS WITH EACH SUPPLIER. VERIFY SUCH OWNER FURNISHED ITEMS WITH OWNERS REPRESENTATIVE, G.C. TO PROVIDE SOLID WOOD BLOCKING AS REQUIRED. CONTRACTOR SHALL REMOVE ALL TEMPORARY ITEMS, TRASH, TOOLS, AND EXCESS MATERIALS AT THE COMPLETION OF WORK AND LEAVE THE ENTIRE PROJECT SITE IN A NEAT, CLEAN, ACCEPTABLE CONDITION. PRIOR TO TURNING THE COMPLETED PROJECT OVER TO THE OWNER, THE CONTRACTOR SHALL REMOVE ALL GREASE, DUST, DIRT, STAINS, LABELS, FINGERPRINTS AND OTHER FOREIGN MATERIALS FROM SIGHT, AND SWEEP, WET-MOP AND VACUUM ALL FLOORS. THE CONTRACTOR SHALL PROVIDE TEMPORARY ELECTRICAL POWER AND LIGHTING AS REQUIRED. THE GENERAL CONTRACTOR SHALL MAINTAIN A SAFE AND SECURE SITE DURING ALL PHASES OF CONSTRUCTION. ALL WORK PERFORMED SHALL COMPLY WITH ALL FEDERAL, STATE AND LOCAL BUILDING CODES AND REQUIREMENTS, AS WELL AS THE MOST RECENT REQUIREMENTS OF THE APPLICABLE ACCESSIBILITY CODES. THE GENERAL CONTRACTOR SHALL SUBMIT A WRITTEN GUARANTEE FOR THEIR MATERIALS AND WORKMANSHIP FOR ONE (1) YEAR FROM THE DATE OF FINAL ACCEPTANCE OF OWNER. DISRUPTED ELECTRICAL AND WATER LINES RE-ROUTED DURING PROJECT CONSTRUCTION ARE TO REMAIN IN CONTINUOUS SERVICE. CONTRACTOR TO VERIFY LOCATION OF ALL EXISTING UNDERGROUND UTILITIES WHERE APPLICABLE PRIOR TO PROCEEDING WITH WORK. ANY EXISTING UTILITIES TO BE ABANDONED SHALL BE PROPERLY DISCONNECTED, PLUGGED OR CAPPED, AS REQUIRED BY CODE AND SOUND CONSTRUCTION PRACTICE. UNLESS OTHERWISE NOTED, ELECTRICAL CONDUITS, PLUMBING LINES, ETC., SHALL BE RUN CONCEALED AND FRAMING SHALL BE ADEQUATE SIZE TO ACCOMPLISH RESULT WITHOUT CAUSING ANY VARIATIONS IN THE WALL PLANE. DISRUPTED EXISTING CONDITIONS I.E. LANDSCAPING, LIGHTING, IRRIGATION, PEDESTRIAN AND VEHICLE ACCESS SHOULD BE MINIMALLY REPLACED AT THE END OF CONSTRUCTION TO THE SAME CONDITIONS PRIOR TO CONSTRUCTION DISRUPTION. CONSTRUCTION NOTES THE SCOPE OF WORK FOR THE PROJECT SHALL INCLUDE ALL LABOR, MATERIALS, DEVICES, SUPPLIES, EQUIPMENT, AND OTHER FACILITIES NECESSARY FOR AND INCIDENTAL TO THE EXECUTION AND COMPLETION OF WORK DESCRIBED IN THESE DOCUMENTS. THE CONTRACTOR SHALL SECURE AND PAY FOR THE BUILDING PERMIT AND OTHER PERMITS AND GOVERNMENT FEES, LICENSES AND INSPECTIONS NECESSARY FOR PROPER EXECUTION AND COMPLETION OF WORK. THE CONTRACTOR SHALL PAY ALL FEDERAL, STATE, LOCAL AND ALL OTHER TAXES THAT ARE APPLICABLE TO THIS CONTRACT. IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO BECOME GENERALLY FAMILIAR WITH THE JOB SITE AND EXISTING CONDITIONS PRIOR TO PROCEEDING WITH WORK. THE CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND CONDITIONS AT THE SITE AND REPORT ANY DISCREPANCIESTO THE ARCHITECT BEFORE PROCEEDING WITH THE WORK. THESE DRAWINGS ARE DIAGRAMMATIC AND SHALL NOT BE SCALED. WHERE LACK OF INFORMATION, OR ANY DISCREPANCY SHOULD APPEAR IN THE DRAWINGS OR SPECIFICATIONS, THE G.C. SHALL REQUEST WRITTEN INTERPRETATION FROM THE ARCHITECT BEFORE PROCEEDING WITH THAT PORTION OF THE WORK. NO CHANGES, MODIFICATIONS OR DEVIATIONS SHALL BE MADE FROM THE DRAWINGS OR SPECIFICATIONS WITHOUT FIRST SECURING WRITTEN PERMISSION FROM THE ARCHITECT. ITEMS LABELED NIC ARE "NOT IN CONTRACT". THE G.C., HOWEVER, IS RESPONSIBLE FOR ALL R.O., NECESSARY BLOCKING AND COORDINATION OF WORK. WHERE A SYSTEM OR ASSEMBLY IS CALLED FOR, ALL NECESSARY PARTS AND MATERIALS REQUIRED FOR A COMPLETE INSTALLATION/SYSTEM SHALL BE PROVIDED AND INSTALLED ACCORDING TO THE MANUFACTURERS INSTRUCTIONS. ALL SYSTEMS & MATERIALS SHALL BE INSTALLED IN STRICT ACCORDANCE WITH THE MANUFACTURERS RECOMMENDATIONS, INSTRUCTIONS AND SPECIFICATIONS. PROVIDE ADEQUATE CONCEALED BLOCKING AND ANCHORING FOR ALL CEILING AND WALL MOUNTED EQUIPMENT, HARDWARE AND ACCESSORIES. COORDINATE WITH ALL TRADES THE LOCATIONS OF SLEEVES, BLOCKING OR OTHER PRESET ACCESSORIES INVOLVING OTHER TRADES. CONTRACTOR TO COORDINATE AND SCHEDULE WORK OF ALL TRADES SO AS TO NOT DELAY AT ANY PHASE OF COMPLETION, CONSTRUCTION DUE TO INTERCONNECTING WORK OR LATE SCHEDULING. IT IS THE RESPONSIBILITY OF THE GENERAL CONTRACTOR TO ENSURE THAT ALL SUB-TRADES ARE FAMILIAR WITH THE COMPLETE CONSTRUCTION DOCUMENTS PACKAGE INCLUDING WORK THAT MAY OR MAY NOT BE PART OF THEIR SCOPE. ALL WORK SHALL BE PERFORMED WITH THE BEST ACCEPTED PRACTICES OF THE RESPECTED TRADES. ALL MATERIALS TO BE NEW (UNLESS OTHERWISE NOTED ON DRAWINGS), FIRST CLASS, IN EVERY RESPECT, AND SHALL CONFORM TO CONTRACT DOCUMENTS. WALL TYPE 1 Scale: 1 1/2"= 1'-0" TYPICAL INTERIOR WALL 5/8" G.W.B. EACH SIDE 3 5/8" METAL STUDS @ 16" O.C. 3 5/8" SOUND INSUL W/ STC-45 RATING WALL TYPE 3 Scale: 1 1/2"= 1'-0" PROVIDE MOISTURE RESISTANT G.W.B AT JANITOR/RESTROOM PARTITIONS 5/8" G.W.B. AND OR 5/8" CEMENT BOARD; VERIFY TILE LOCATION FOR CEMENT BOARD HEIGHT 6" METAL STUDS @ 16" O.C. 5 1/2" SOUND INSUL W/ STC-45 RATING WALL TYPE 2 Scale: 1 1/2"= 1'-0" 3 5/8" METAL STUDS @ 16" O.C. 3 5/8" SOUND INSUL W/ STC-45 RATING PROVIDE MOISTURE RESISTANT G.W.B AT JANITOR/RESTROOM PARTITIONS WALL TILE AS SPECIFIED: LOCATED IN RESTROOM & SHOWERS 5/8" G.W.B. AND OR 5/8" CEMENT BOARD; VERIFY TILE LOCATION FOR CEMENT BOARD HEIGHT WALL TILE AS SPECIFIED: LOCATED IN RESTROOM & SHOWERS PROVIDE MOISTURE RESISTANT G.W.B AT JANITOR/RESTROOM PARTITIONS Scale Date Drawn By Checked By Project Number ©COPYRIGHT ALL RIGHTS RESERVED. NO USE OR REPRODUCTION OF THIS MATERIAL IS PERMITTED WITHOUT WRITTEN CONSENT DO NOT SCALE DRAWING, USE DIMENSIONS SHOWN. VERIFY ALL DIMENSIONS ON SITE. As indicated Proposed Plan & Notes Proposed Tenant Fit-out Anytime Fitness RSH RSH 7-18-17 2017001 135 KING STREET NORTHAMPTON, MA A1.13/16" = 1'-0"1Proposed Floor PlanNo. Description Date EXISTING SIGNAGE TO BE DEMOLISHED PREP OPENINGS FOR NEW WINDOWS ALL CORRUGATED F.G. PANELS TO BE DEMOLISHED EXISTING SIGNAGE TO BE DEMOLISHED PREP OPENINGS FOR NEW WINDOWS ALL CORRUGATED F.G. PANELS TO BE DEMOLISHED PREP OPENINGS FOR NEW WINDOWS PREP OPENINGS FOR NEW WINDOWS ALL CORRUGATED F.G. PANELS TO BE DEMOLISHED EXISTING HVAC UNIT Scale Date Drawn By Checked By Project Number ©COPYRIGHT ALL RIGHTS RESERVED. NO USE OR REPRODUCTION OF THIS MATERIAL IS PERMITTED WITHOUT WRITTEN CONSENT DO NOT SCALE DRAWING, USE DIMENSIONS SHOWN. VERIFY ALL DIMENSIONS ON SITE. 3/16" = 1'-0" Exterior Elevations- Existing Proposed Tenant Fit-out Anytime Fitness RSH KNH 7-18-17 2017001 135 KING STREET NORTHAMPTON, MA A2.0 No. Description Date 3/16" = 1'-0"1 Existing Front Elevation 3/16" = 1'-0"2 Existing Left Elevation 3/16" = 1'-0"3 Existing Right Elevation 3/16" = 1'-0"4 Existing Rear Elevation NEW EXTERIOR SIGNAGE G.C. TO PROIVED PHOTOCELL EXISTING HVAC UNIT G.C. TO INSTALL NEW HARDIE PANEL WITH PVC TRIM. FLASH AND SEAL AS REQUIRED; PAINT COLOR TBD NEW ALUMINUM STOREFRONT TO MATCH EXISTING; G.C. TO VERIFY EXISTING R.O. & PROVIDE HEAD,JAMB & SILL FLASHING G.C. TO INSTALL NEW HARDIE PANEL WITH PVC TRIM, FLASH AND SEAL AS REQUIRED; PAINT COLOR TBD G.C. TO FURNISH AND INSTALL WHITE VINYL PRIVACY FENCE OWNER SUPPLIED AWNING G.C. TO INSTALL NEW HARDIE PANEL WITH PVC TRIM, FLASH AND SEAL AS REQUIRED; PAINT COLOR TBD G.C. TO INSTALL NEW HARDIE PANEL WITH PVC TRIM, FLASH AND SEAL AS REQUIRED; PAINT COLOR TBD NEW ALUMINUM STOREFRONT TO MATCH EXISTING; G.C. TO VERIFY EXISTING R.O. & PROVIDE HEAD,JAMB & SILL FLASHING APPLIED VINYL GRAPHIC SLIM LINE RAB WALLPACK DOWN LIGHT CONNECTED TO COMMON PHOTOCELL OWNER SUPPLIED AWNING NEW ALUMINUM STOREFRONT TO MATCH EXISTING; G.C. TO VERIFY EXISTING R.O. & PROVIDE HEAD,JAMB & SILL FLASHING G.C. TO INSTALL NEW HARDIE PANEL WITH PVC TRIM, FLASH AND SEAL AS REQUIRED; PAINT COLOR TBD APPLIED VINYL GRAPHIC SLIM LINE RAB WALLPACK DOWN LIGHT CONNECTED TO COMMON PHOTOCELL Scale Date Drawn By Checked By Project Number ©COPYRIGHT ALL RIGHTS RESERVED. NO USE OR REPRODUCTION OF THIS MATERIAL IS PERMITTED WITHOUT WRITTEN CONSENT DO NOT SCALE DRAWING, USE DIMENSIONS SHOWN. VERIFY ALL DIMENSIONS ON SITE. 3/16" = 1'-0" Exterior Elevaitons- Proposed Proposed Tenant Fit-out Anytime Fitness RSH RSH 7-18-17 2017001 135 KING STREET NORTHAMPTON, MA A2.1 No. Description Date 3/16" = 1'-0"1 Proposed Front Elevation 3/16" = 1'-0"2 Proposed Rear Elevation 3/16" = 1'-0"3 Proposed Right Elevation 3/16" = 1'-0"4 Proposed Left Elevation