Loading...
36 -309 engineer letter• RYAN S. HELLWIG, PE • STRUCTURAL ENGINEER • December 13, 2012 Mark O. Gelotte, Architect 70 Elm Street Hatfield MA 0103 8 ms elg otte@verizon.net Re: Bayuk Residence 125 Cardinal Way Florence, MA Subject: Beam Reinforcement for Removal of Existing Columns Design Criteria 1St Floor Live Load = 40 psf Residential 2"a Floor Live Load = 30 psf Sleeping Areas Beam #1 Beam #2 Existing Beam = (3) 2 x 12 Span = 12'- 6" Supporting 1St Floor Live Loads only Span = 10'- 0" Supporting 1St & 2' Floor Live Loads Beam Reinforcement 2L 8 x 2%2 x %2 LLV A36 steel (to be cut from L 8 x 4 x %2 or larger stock) Attach vertical legs to existing beam w/ 3/8" dia. x 4" lag screws @ 24" o/c Supports 31/2" diameter concrete filled 16 gauge steel pipe column 1/2" x 51/2" x 8" column cap 12" x 30" x 30" column footing 3" minimum bearing on existing concrete foundation wall • 28 ALDRICH STREET • NORTHAMPTON, MA 01060 • 0 VOICE 413-584-HLWG (4594) 0 FAX 413-584-HLWFax (4593) 0