Loading...
38B-029 123 South Street Code Review 2013 code review  Gillen Collaborative Architects 409 Main Street Amherst, MA 01002 Tel 413-253-2529 fgaoffice@fordgillen.com William V. Gillen, AIA  RE: Mayfair Residential Condos - Structural Repairs, Window Replacement, Siding DATE: 12/20/13 FGA NO.: 3047 CODE REFERENCE EXISTING BUILDING STATISTICS  Address 123 South St.  Area Gross s.f. floor area: 1,655 s.f.  Footprint Gross s.f.: 2331 s.f.  Use Group (Table 301.1) Residential R-2  Occupancy Table 1004.1.1: 200 gross s.f./person  10 apartments, 2 per floor, 5 floors = 58 occupancy  Building classification Type III-B  Table 601 Non combustible exterior and wood frame supports. The work of this project involves repairing and residing the existing back stair enclosure. This enclosure is wood framed with a stucco finish. Classification of this portion of the building: V-A.  Built dates Original construction: 1920s, porch enclosure: circa 1950;  Height (Table 503) 4 floors 42’ at the back elevation 5 floors (non conforming).   Code Review Alteration of an existing building 780 CMR 8th Edition, AAB Code 521 CMR, IEBC 2009 edition CODE REFERENCE PROPOSED WORK  Chapter 4 Classification of Work   403.1 Level 1 Alterations  This project is re-siding, window replacement and framing repair in stairhall only. This is a Level 1 alteration.  403.2 Application Level 1 alterations shall comply with the provisions of Chapter 6  See below   CODE REFERENCE PROPOSED WORK  Chapter 6 Alterations Level 1    General alterations shall be done in a manner that maintains level of fire protection provided. No change in the fire protection provided: new siding over existing stucco and replacement windows; misc structural repair.  Repairs shall be done in a manner that maintains a level of protection provided for the means of egress. Provisions shall be made so that this egress is maintained and protected during the entire course of construction  Accessibility shall be in accordance with 521 CMR The existing accessibility is not being changed in the scope of this work (siding and windows).  606 Structural Structural work of this project involves the replacement of rotten wood framing. These structural elements will be defined in structural drawings (copy attached)  607.1 Minimum Requirements Level 1 alterations to an existing buildings are permitted without requiring the entire building or structure to comply with the energy requirements of the IECC. These alterations shall conform to the energy requirements of the IECC as they relate to new construction only.  The exterior wall will include full depth high density cellulose and will provide an R-14. Because of the existing 2x4 framing of the walls the insulation is limited to this depth.   William V. Gillen RJ;3047\CodeReview