Vertical Section at Toilet Cavity SKA003CORRIDOR
BATHROOM
5/8" TYPE "X" GYP BOARD ON 2x4 FURRING - NOT RATED
1-HOUR RATED FLOOR ASSEMBLY (UL-L544):
- 3/4" MIN. GYPCRETE UNDERLAYMENT
- 3/4" T&G PLYWOOD SUBFLOOR
- WOOD I-JOISTS
- 3-1/2" MIN SOUND ATTENUATION BATTS
- 1/2" RESILIENT CHANNELS @ 24" O.C
- (2) LAYERS 5/8" TYPE "X" GYP BOARD
(SCREWS ARE NOT TO PENETRATE JOISTS)
CORRIDOR2' - 0"CONTINUOUS VENT RISERCONTINUOUS VENT RISERFIRE RATEDACCESS PANEL(IF REQD.)ACCESSIBLE
ACT CEILING
TYPE "C" 1-HOUR RATED WALL CONSTRUCTION (UL-U309):
(FROM CORRIDOR SIDE)
- 5/8" TYPE "X" GYPSUM BOARD
- 1/2" SHEAR PANEL
- 2x6 LOAD BEARING WOOD STUD W/ 3 1/2" MIN SOUND
ATTENUATION BATT IN STUD CAVITY
- 1/2 RESILIENT CHANNEL (NOT REQD. BEHIND FURRING)
- 5/8" TYPE "X" GYPSUM BOARD
F.D.
IF REQD.
FIRE SEALANT AND/OR SLEEVE AT DUCT & PIPE
PENETRATIONS OF 1-HOUR RATED FLOOR/CEILING
ASSEMBLY AS REQUIRED BY CODE
GRID
LINE
FIRE SEALANT AND/OR SLEEVE AT DUCT & PIPE
PENETRATIONS OF 1-HOUR RATED FLOOR/CEILING
ASSEMBLY AS REQUIRED BY CODE
26 GA. CONTINUOUS VENT DUCT TO ROOF - FIRE
DAMPERS SHOULD NOT BE REQUIRED AT FIRE-RATED
FLOOR/CEILING SEPARATION PER EXEMPTION IN 2009 IBC
SECTION 716 WITH CONTINUOUS VENTILATION
PROVIDED BY FAN AT TOP OF VENT DUCT RUN
SPACE BETWEEN 2x4 FURRED WALL AND 2x6 RATED WALL
WHERE PLUMBING AND DUCTWORK RUNS IS NOT A SHAFT - IT
IS A ONE-STOREY UNRATED WALL CAVITY BOUNDED AT TOP
AND BOTTOM BY 1-HOUR RATED FLOOR/CEILING ASSEMBLY
BATHROOM
FLOOR LEVEL
NON-ACCESSIBLE, NON-RATED GYP
BOARD BATHROOM CEILING
SPUR DUCT TO BATHROOM LIGHT/VENT UNIT THROUGH
NON-RATED FURRED WALL - NO FIRE DAMPER REQUIRED
Steffian Bradley ArchitectsOne Corporate Road, Suite 102
Enfield, CT 06082.6036
T 860.627.1920 F 860.627.1930
www.steffian.com
Project NumberProject NumberProject NumberProject Number ScaleScaleScaleScale
IssueIssueIssueIssueDateDateDateDate
TitleTitleTitleTitle
1 1/2" = 1'-0" 1 1/2" = 1'-0" 1 1/2" = 1'-0" 1 1/2" = 1'-0"3/14/2014 12:27:07 AMSKA-003SKA-003SKA-003SKA-003
VERTICAL SECTIONVERTICAL SECTIONVERTICAL SECTIONVERTICAL SECTION
AT TOILETAT TOILETAT TOILETAT TOILET
MECHANICALSMECHANICALSMECHANICALSMECHANICALS
02455.00002455.00002455.00002455.000Fairfield Inn Northampton
Tala Hotels Holding, LLC 14 March 2014 For Information