Loading...
44 -018 1st floor girder calcs CalcCS Structure™ 2.10.1 [Build 1] kmBeamEngine 4.13.4.1 Materials Database 1527 RainbowHomeImpBecker - Level 6 6-10-15 9:53am 1 of 4 All product names are trademarks of their respective owners Copyright (C) 2015 by Simpson Strong-Tie Company Inc. ALL RIGHTS RESERVED.**Passing is defined as when the member, floor joist, beam or girder, shown on this drawing meets applicable design criteria for Loads, Loading Conditions, and Spans listed on this sheet. The design must be reviewed by a qualified designer or design professional as required for approval. This design assumes product installation according to the manufacturer`s specifications. Doug Hodgins rk Miles Inc. 21 West St. West Hatfield Ma. Member Data Description: CalcG3 Member Type: Girder Application: Floor Comments:Top Lateral Bracing: Continuous Bottom Lateral Bracing: Continuous Standard Load: Moisture Condition: Dry Building Code: IBC/IRC Live Load: 0 PLF Deflection Criteria: L/360 live, L/240 total Dead Load: 0 PLF Deck Connection: Nailed Member Weight: 8.4 PLF Filename: Q:\RainbowHo Other Loads Type (Description) Side Begin End Trib. Width Other Start End Dead Start End Category Replacement Uniform (PLF) Top 1' 4.00" 12' 5.00" 210 53 Live Point (LBS) Top 0' 4.63" 4 840 Live Point (LBS) Top 0' 4.63" 1980 0 Snow Point (LBS) Top 13' 4.38" 4 840 Live Point (LBS) Top 13' 4.38" 1980 0 Snow 1 2 1 4 0 11 1 0 1 4 0 13 9 0 Bearings and Reactions Input Min Gravity Gravity Location Type Material Length Required Reaction Uplift 1 1' 4.000" Wall N/A N/A 1.500" 1509# -- 2 12' 5.000" Wall N/A N/A 1.500" 1509# -- Maximum Load Case Reactions Used for applying point loads (or line loads) to carrying members Live Snow Dead 1 1164# 0# 345# 2 1164# 0# 345# Design spans 0' 11.375" (left cant) 11' 1.000" 0' 11.375" (right cant) Product: Spruce-Pine-Fir #2 2 x 10 3 ply PASSES DESIGN CHECKS NOTE: Pass-thru framing is required at point loads over bearings. Design assumes continuous lateral bracing along the top chord. Design assumes continuous lateral bracing along the bottom chord. Allowable Stress Design Actual Allowable Capacity Location Loading Positive Moment 4156.# 5919.# 70% 6.88' Total Load D+L Negative Moment 4.# 5327.# 0% 1.33' Total Load D Shear 1292.# 3746.# 34% 11.86' Total Load D+L LL Deflection 0.1716" 0.3694" L/775 6.88' Total Load L TL Deflection 0.2211" 0.5542" L/601 6.88' Total Load D+L LL Defl., Lt. -0.0470" 0.2000" 2L/484 0' Total Load L TL Defl., Lt. -0.0605" 0.2000" 2L/376 0' Total Load D+L LL Defl., Rt. -0.0470" 0.2000" 2L/484 13.75' Total Load L TL Defl., Rt. -0.0605" 0.2000" 2L/376 13.75' Total Load D+L Control: Positive Moment DOLs: Live=100% Snow=115% Roof=125% Wind=160% Design assumes a repetitive member use increase in bending stress: 15 % This member has been designed in accordance with NDS 2005 Point loads over bearings are NOT included in the Design calculations, but ARE included in the Reaction table CS Structure™ 2.10.1 [Build 1] kmBeamEngine 4.13.4.1 Materials Database 1527 RainbowHomeImpBecker - Level 6 6-10-15 9:53am 2 of 4 All product names are trademarks of their respective owners Copyright (C) 2015 by Simpson Strong-Tie Company Inc. ALL RIGHTS RESERVED.**Passing is defined as when the member, floor joist, beam or girder, shown on this drawing meets applicable design criteria for Loads, Loading Conditions, and Spans listed on this sheet. The design must be reviewed by a qualified designer or design professional as required for approval. This design assumes product installation according to the manufacturer`s specifications. Doug Hodgins rk Miles Inc. 21 West St. West Hatfield Ma. Member Data Description: CalcG4 Member Type: Girder Application: Floor Comments:Top Lateral Bracing: Continuous Bottom Lateral Bracing: Continuous Standard Load: Moisture Condition: Dry Building Code: IBC/IRC Live Load: 0 PLF Deflection Criteria: L/360 live, L/240 total Dead Load: 0 PLF Deck Connection: Nailed Member Weight: 8.4 PLF Filename: Q:\RainbowHo Other Loads Type (Description) Side Begin End Trib. Width Other Start End Dead Start End Category Replacement Uniform (PLF) Top 0' 0.00" 10' 11.50" 5 1 Live Replacement Uniform (PLF) Top 0' 0.00" 10' 11.50" 27 7 Live 1 2 1 4 0 9 7 8 10 11 8 Bearings and Reactions Input Min Gravity Gravity Location Type Material Length Required Reaction Uplift 1 1' 4.000" Wall N/A N/A 1.500" 269# -- 2 10' 11.500" Wall N/A N/A 1.500" 221# -- Maximum Load Case Reactions Used for applying point loads (or line loads) to carrying members Live Dead 1 178# 92# 2 146# 75# Design spans 0' 11.375" (left cant) 9' 2.875" Product: Spruce-Pine-Fir #2 2 x 10 3 ply PASSES DESIGN CHECKS Design assumes continuous lateral bracing along the top chord. Design assumes continuous lateral bracing along the bottom chord. Allowable Stress Design Actual Allowable Capacity Location Loading Positive Moment 508.# 5919.# 8% 5.95' Even Spans D+L Negative Moment 22.# 5919.# 0% 1.33' Total Load D+L Shear 187.# 3746.# 4% 1.34' Total Load D+L LL Deflection 0.0125" 0.3080" L/999+ 5.95' Even Spans L TL Deflection 0.0188" 0.4620" L/999+ 5.95' Even Spans D+L LL Defl., Lt. -0.0041" 0.2000" 2L/999+ 0' Even Spans L TL Defl., Lt. -0.0061" 0.2000" 2L/999+ 0' Even Spans D+L Control: Positive Moment DOLs: Live=100% Snow=115% Roof=125% Wind=160% Design assumes a repetitive member use increase in bending stress: 15 % This member has been designed in accordance with NDS 2005 CS Structure™ 2.10.1 [Build 1] kmBeamEngine 4.13.4.1 Materials Database 1527 RainbowHomeImpBecker - Level 6 6-10-15 9:53am 3 of 4 All product names are trademarks of their respective owners Copyright (C) 2015 by Simpson Strong-Tie Company Inc. ALL RIGHTS RESERVED.**Passing is defined as when the member, floor joist, beam or girder, shown on this drawing meets applicable design criteria for Loads, Loading Conditions, and Spans listed on this sheet. The design must be reviewed by a qualified designer or design professional as required for approval. This design assumes product installation according to the manufacturer`s specifications. Doug Hodgins rk Miles Inc. 21 West St. West Hatfield Ma. Member Data Description: CalcG5 Member Type: Girder Application: Floor Comments:Top Lateral Bracing: Continuous Bottom Lateral Bracing: Continuous Standard Load: Moisture Condition: Dry Building Code: IBC/IRC Live Load: 0 PLF Deflection Criteria: L/360 live, L/240 total Dead Load: 0 PLF Deck Connection: Nailed Member Weight: 8.4 PLF Filename: Q:\RainbowHo Other Loads Type (Description) Side Begin End Trib. Width Other Start End Dead Start End Category Replacement Uniform (PLF) Top 0' 0.00" 10' 11.50" 5 1 Live Replacement Uniform (PLF) Top 0' 0.00" 10' 11.50" 27 7 Live Point (LBS) Top 0' 4.63" 2 350 Live Point (LBS) Top 0' 4.63" 829 0 Snow 1 2 9 7 8 1 4 0 10 11 8 Bearings and Reactions Input Min Gravity Gravity Location Type Material Length Required Reaction Uplift 1 0' 0.000" Wall N/A N/A 1.500" 1254# -- 2 9' 7.500" Wall N/A N/A 1.500" 269# -- Maximum Load Case Reactions Used for applying point loads (or line loads) to carrying members Live Snow Dead 1 149# 829# 425# 2 178# 0# 92# Design spans 9' 2.875" 0' 11.375" (right cant) Product: Spruce-Pine-Fir #2 2 x 10 3 ply PASSES DESIGN CHECKS NOTE: Pass-thru framing is required at point loads over bearings. Design assumes continuous lateral bracing along the top chord. Design assumes continuous lateral bracing along the bottom chord. Allowable Stress Design Actual Allowable Capacity Location Loading Positive Moment 508.# 5919.# 8% 5.01' Odd Spans D+L Negative Moment 22.# 5919.# 0% 9.62' Total Load D+L Shear 187.# 3746.# 4% 9.16' Total Load D+L LL Deflection 0.0125" 0.3080" L/999+ 5.01' Odd Spans L TL Deflection 0.0188" 0.4620" L/999+ 5.01' Odd Spans D+L LL Defl., Rt. -0.0041" 0.2000" 2L/999+ 10.96' Odd Spans L TL Defl., Rt. -0.0061" 0.2000" 2L/999+ 10.96' Odd Spans D+L Control: Positive Moment DOLs: Live=100% Snow=115% Roof=125% Wind=160% Design assumes a repetitive member use increase in bending stress: 15 % This member has been designed in accordance with NDS 2005 Point loads over bearings are NOT included in the Design calculations, but ARE included in the Reaction table CS Structure™ 2.10.1 [Build 1] kmBeamEngine 4.13.4.1 Materials Database 1527 RainbowHomeImpBecker - Level 6 6-10-15 9:53am 4 of 4 All product names are trademarks of their respective owners Copyright (C) 2015 by Simpson Strong-Tie Company Inc. ALL RIGHTS RESERVED.**Passing is defined as when the member, floor joist, beam or girder, shown on this drawing meets applicable design criteria for Loads, Loading Conditions, and Spans listed on this sheet. The design must be reviewed by a qualified designer or design professional as required for approval. This design assumes product installation according to the manufacturer`s specifications. Doug Hodgins rk Miles Inc. 21 West St. West Hatfield Ma. Member Data Description: CalcG6 Member Type: Girder Application: Floor Comments:Top Lateral Bracing: Continuous Bottom Lateral Bracing: Continuous Standard Load: Moisture Condition: Dry Building Code: IBC/IRC Live Load: 0 PLF Deflection Criteria: L/360 live, L/240 total Dead Load: 0 PLF Deck Connection: Nailed Member Weight: 5.7 PLF Filename: Q:\RainbowHo Other Loads Type (Description) Side Begin End Trib. Width Other Start End Dead Start End Category Replacement Uniform (PLF) Top 0' 0.00" 10' 9.50" 27 7 Live Replacement Uniform (PLF) Top 0' 0.00" 13' 11.25" 5 1 Live Replacement Uniform (PLF) Top 10' 9.50" 13' 11.25" 27 7 Live Replacement Uniform (PLF) Top 10' 11.50" 13' 11.25" 250 0 Snow 1 2 3 9 4 0 4 4 0 0 3 4 13 11 4 Bearings and Reactions Input Min Gravity Gravity Location Type Material Length Required Reaction Uplift 1 0' 0.000" Wall N/A N/A 1.500" 167# -- 2 9' 4.000" Wall N/A N/A 1.500" 534# -- 3 13' 8.000" Wall N/A N/A 1.500" 457# -40# Maximum Load Case Reactions Used for applying point loads (or line loads) to carrying members Live Snow Dead 1 118# -12# 49# 2 292# 253# 125# 3 65# 451# 7# Design spans 8' 11.375" 4' 4.000" 0' 0.625" (right cant) Product: SYP (PT) #1 2 x 8 2 ply PASSES DESIGN CHECKS Design assumes continuous lateral bracing along the top chord. Design assumes continuous lateral bracing along the bottom chord. Allowable Stress Design Actual Allowable Capacity Location Loading Positive Moment 373.# 3778.# 9% 11.93' Even Spans D+S Negative Moment 340.# 3285.# 10% 9.33' Adjacent 1 D+L Shear 303.# 2918.# 10% 9.34' Adjacent 1 D+0.75(L+S) LL Deflection 0.0170" 0.2983" L/999+ 4.41' Odd Spans L TL Deflection 0.0237" 0.4474" L/999+ 4.41' Odd Spans D+L LL Defl., Rt. 0.0010" 0.2000" 2L/999+ 13.94' Even Spans S TL Defl., Rt. 0.0010" 0.2000" 2L/999+ 13.94' Even Spans D+S Control: Shear DOLs: Live=100% Snow=115% Roof=125% Wind=160% This member has been designed in accordance with NDS 2005