Loading...
43 -110 16063144B-Hall_Smith-rk-062516-DwgsOVERHANG INFO HEEL HEIGHT GABLE STUDS 00-07-00 24 IN. OC END CUT RETURN SQUARE REQ. ENGINEERING JOBSITE REQ. LAYOUTS JOBSITE 2 2 QUOTE LAYOUT CUTTING BRT BRT DATEBY SHIP TO 24 West St Hatfield, MA 01038 R.K. Miles-HatfieldSOLD TO (413) 247-8300 SALES REP ORDER DATE REQ. QUOTE DATE DELIVERY DATE / / / / / /ORDER # QUOTE # TERMS SALES AREA CUSTOMER PO # CUSTOMER ACCT # INVOICE # LMCWRKMI ORDERED BY SUPERINTENDENT JOBSITE PHONE # DATE OF INVOICE 16063144B Brian Tetreault Massachusetts / / / Wayne Helms (413) 247-8314 PAGE 1 SPECIAL INSTRUCTIONS: *Garage only based on 05-13-16 plans. DELIVERY INSTRUCTIONS: JOB NAME: MODEL: TAG: Hall / Smith Residence Garage BUILDING DEPARTMENT Roof Trusses JOB CATEGORY: Residential LOT # SUBDIV: DATE06/25/16 107 Whittier Street Northampton, MA 01060 Hall / Smith Residence Wayne Helms 06/25/16 06/25/16 / / 155 Bay Road, PO Box 945, Belchertown, MA. 01007 Phone: 413-323-7247 Fax: 413-323-5257 UFP Belchertown, LLC QTY TYPE SPAN LUMBER TOP BOT OVERHANG LEFT RIGHT CANTILEVER LEFT RIGHT PITCH TOP BOTID TOTALPRICEPRICEUNITPROFILE ROOF TRUSSES LOADING TCLL-TCDL-BCLL-BCDL 40.0,10.0,0.0,10.0 STRESS INCR. 1.15INFORMATION ROOF TRUSS SPACING:24.0 IN. O.C. (TYP.)ROOF TRUSSES LOADING TCLL-TCDL-BCLL-BCDL 40.0,10.0,0.0,10.0 STRESS INCR. INFORMATION PLY LEFT RIGHT STUBO/ABASE SPAN M01 2.25 0.00 24-00-00 00-06-00 00-06-002 X 6 2 X 4 MONOPITCH 14 24-00-00 M01GE 2.25 0.00 24-00-00 00-06-00 00-06-002 X 6 2 X 4 GABLE 2 24-00-00 ROOF SUB-TOTAL: ACCEPTED BY BUYER PURCHASER: BY: TITLE: ADDRESS: PHONE: DATE: ACCEPTED BY SELLER BY: TITLE: DATE OF ACCEPTANCE: SUB-TOTAL GRAND TOTAL Quote is based on current design values at the time of quote (lumber, EWP, hardware, etc). Should any of these values change prior to completion of this project, reserves the right to adjust the sell price accordingly. UFP Belchertown, LLC QUOTE POLICY: QUOTE VALID FOR 15 DAYS. AFTER 15 DAYS, UFP RESERVES THE RIGHT TO REVIEW / ADJUST ALL PRICING. Sealed individual truss drawings are included in the pricing. Sealed layouts, stamped bracing diagrams are NOT included BUT can be provided for an additional charge. Truss ListTruss Qty SpanM01 14 24' 0"M01GE 2 24' 0"M01GEM01GEM01(14)30' 0" 30' 0" 24' 0"24' 0"1' 11 1/4"2' 0" 2' 0" 2' 0" 2' 0" 2' 0" 2' 0" 2' 0" 2' 0" 2' 0" 2' 0" 2' 0" 2' 0" 2' 0" 2.256"6"24' 0"7"1 1/8"5' 2 1/8"5' 1"Roof Area 788.51Sheathing Count 27Overhang Lines 62Raked Lines 50.87Ridge Lines 0Hip Lines 0Valley Lines 0THIS IS A TRUSS PLACEMENT DIAGRAM ONLY. These trusses are designed as individual building components to beincorporated into the building design at the specificationof the building designer. See individual design sheets for eachtruss design identified on the placement drawing. The building designer is responsible for temporary and permanent bracingof the roof and floor system and for the overall structure. The design of the truss support structure including headers, beams,walls, and columns is the responsibility of the building designer. For general guidance regarding bracing, consult "Bracing ofwood trusses" available from the Truss Plate Institute, 583D'Onifrio Drive; Madison, WI 53179. It is the responsiblility of theGeneral Contractor/Superintendent to verify that the provided truss layout shall match the final intended construction plans,loading conditions, and use. If they do not, it is the responsiblility of the General Contractor/Superintendent to provideprints/plans containing the latest specifications and designs. Universal Forest Products will not be responsible forprint/planchanges by others after final approval ofshop drawings, norwill they be responsible for errors or modifications made on-siteduring construction. DO NOT CUT, NOTCH, DRILL, OR OTHERWISE"REPAIR" MANUFACTURED TRUSSES IN ANY WAYWITHOUT PRIOR WRITTEN AUTHORIZATION BY A LICENSED PROFESSIONAL DESIGNATED BY UFP. UFP WILL NOTBE HELD RESPONSIBLE FOR ANY MODIFICATIONS OR "CHARGE BACKS"DONE WITHOUT PRIOR WRITTENAUTHORIZATION FROM UFPHall / Smith Residence107 Whittier St. Northampton, MA6/25/16Garage Trusses-For Approval16033144BThe following information is anapproximate and NOT guaranteed Job 16063144B Truss M01 Truss Type MONOPITCH Qty 14 Ply 1 107 Whittier St. Northampton, MA Job Reference (optional)7.640 s Apr 8 2016 MiTek Industries, Inc. Sat Jun 25 07:25:15 2016 Page 1 Universal Forest Products ID:JOpwJy1umOSKy42E6xQxHGz2qE0-xP52LlVIQFUlF1vCt0Y?ta0QwjAXqcINLfhpkDz2q9Y Scale = 1:40.9 T2 W5 B1 W1 W2 W3 W4 T1 B2 1 2 3 4 5 6 7 10 9 8 14 4x6 6x8 3x4 4x10 3x4 1.5x3 7x14 MT20HS 2x4 25-5-4 8-2-11 8-2-11 16-0-0 7-9-5 24-0-0 8-0-0 -0-6-0 0-6-0 8-2-11 8-2-11 16-0-0 7-9-5 24-0-0 8-0-0 24-6-0 0-6-0 0-7-05-1-155-1-02.25 12 Plate Offsets (X,Y)-- [6:0-3-12,0-2-8], [9:0-7-0,0-3-4] LOADING (psf)TCLL (Roof Snow=40.0) TCDL BCLL BCDL 40.0 10.0 0.0 * 10.0 SPACING-Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-01.15 1.15 YES IRC2009/TPI2007 CSI.TC BC WB (Matrix-M) 0.66 0.64 0.84 DEFL.Vert(LL) Vert(TL) Horz(TL) Wind(LL) in-0.42 -0.71 0.11 0.10 (loc)9-10 9-10 8 9-10 l/defl>681 >402 n/a >999 L/d240 180 n/a 360 PLATESMT20 MT20HS Weight: 104 lb FT = 4% GRIP197/144 148/108 LUMBER-TOP CHORD 2x6 SPF No.2 BOT CHORD 2x4 SPF 2100F 1.8E WEBS 2x4 SPF No.2 *Except* W5: 2x6 SPF No.2 BRACING-TOP CHORD Structural wood sheathing directly applied or 2-7-13 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 3-9 MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS.(lb/size)8=1495/0-3-8 (min. 0-2-14), 2=1480/0-3-8 (min. 0-2-8)Max Horz2=113(LC 7)Max Uplift8=-26(LC 6), 2=-28(LC 8)Max Grav8=1844(LC 2), 2=1586(LC 2) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-5146/530, 3-14=-3142/303, 4-14=-3073/303, 4-5=-2991/310, 5-6=-3182/363, 6-8=-1770/237BOT CHORD 2-10=-523/4986, 9-10=-523/4986WEBS3-10=0/286, 3-9=-2026/270, 5-9=-1142/208, 6-9=-360/3415 NOTES- 1) Wind: ASCE 7-05; 90mph; TCDL=5.0psf; BCDL=5.0psf; h=24ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) and C-C Exterior(2) zone; cantilever left exposed ; end vertical right exposed;C-C for members and forces & MWFRS for reactions shown; LumberDOL=1.60 plate grip DOL=1.332) TCLL: ASCE 7-05; Pf=40.0 psf (flat roof snow); Category II; Exp B; Partially Exp.; Ct=1.1 3) Unbalanced snow loads have been considered for this design. 4) This truss has been designed for greater of min roof live load of 20.0 psf or 2.00 times flat roof load of 40.0 psf on overhangs non-concurrent with other live loads. 5) All plates are MT20 plates unless otherwise indicated. 6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.7) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 widewill fit between the bottom chord and any other members. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 8, 2. 9) This truss is designed in accordance with the 2009 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1.10) "Semi-rigid pitchbreaks including heels" Member end fixity model was used in the analysis and design of this truss. LOAD CASE(S)Standard Job 16063144B Truss M01GE Truss Type GABLE Qty 2 Ply 1 107 Whittier St. Northampton, MA Job Reference (optional)7.640 s Apr 8 2016 MiTek Industries, Inc. Sat Jun 25 07:25:27 2016 Page 1 Universal Forest Products ID:JOpwJy1umOSKy42E6xQxHGz2qE0-ajqasreqbx?2itqVaXmpM6WaeZOEeE485WbR9Wz2q9M Scale = 1:40.9 T2 W1 B1 T1 B2 ST9ST8ST7ST6ST5ST4ST3ST2ST112 3 4 5 6 7 8 9 10 11 12 13 14 24 23 22 21 20 19 18 17 16 15 4x6 3x4 1.5x3 1.5x3 1.5x3 5x6 1.5x3 1.5x3 1.5x3 1.5x3 1.5x3 1.5x3 25-5-4 24-0-0 24-0-0 -0-6-0 0-6-0 24-0-0 24-0-0 24-6-0 0-6-0 0-7-05-1-155-1-02.25 12 Plate Offsets (X,Y)-- [19:0-3-0,0-3-0] LOADING (psf)TCLL (Roof Snow=40.0) TCDL BCLL BCDL 40.0 10.0 0.0 * 10.0 SPACING-Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-01.15 1.15 YES IRC2009/TPI2007 CSI.TC BC WB (Matrix) 0.29 0.14 0.08 DEFL.Vert(LL) Vert(TL) Horz(TL) in-0.00 -0.00 0.00 (loc)13 13 15 l/defln/r n/r n/a L/d180 80 n/a PLATESMT20 Weight: 106 lb FT = 4% GRIP197/144 LUMBER-TOP CHORD 2x6 SPF No.2 BOT CHORD 2x4 SPF 2100F 1.8E WEBS 2x6 SPF No.2 OTHERS 2x4 SPF No.2 BRACING-TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing. MiTek recommends that Stabilizers and required cross bracingbe installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS.All bearings 24-0-0. (lb) - Max Horz2=114(LC 7)Max Uplift All uplift 100 lb or less at joint(s) 15, 2, 17, 18, 19, 20, 21, 22, 23, 24Max Grav All reactions 250 lb or less at joint(s) 15 except 2=348(LC 2), 16=292(LC 2), 17=319(LC 2), 18=312(LC 2), 19=312(LC 2), 20=318(LC 2), 21=266(LC 2), 22=299(LC 1), 24=775(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.WEBS 12-16=-251/21, 11-17=-279/54, 10-18=-272/51, 9-19=-273/50, 8-20=-277/51, 3-24=-633/153 NOTES- 1) Wind: ASCE 7-05; 90mph; TCDL=5.0psf; BCDL=5.0psf; h=24ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) and C-C Exterior(2) zone; cantilever left exposed ; end vertical right exposed;C-C for members and forces & MWFRS for reactions shown; LumberDOL=1.60 plate grip DOL=1.332) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 3) TCLL: ASCE 7-05; Pf=40.0 psf (flat roof snow); Category II; Exp B; Partially Exp.; Ct=1.1 4) Unbalanced snow loads have been considered for this design. 5) This truss has been designed for greater of min roof live load of 20.0 psf or 2.00 times flat roof load of 40.0 psf on overhangsnon-concurrent with other live loads.6) All plates are 2x4 MT20 unless otherwise indicated.7) Gable requires continuous bottom chord bearing. 8) Gable studs spaced at 2-0-0 oc. 9) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 10) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 widewill fit between the bottom chord and any other members.11) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 15, 2, 17, 18, 19,20, 21, 22, 23, 24. 12) This truss is designed in accordance with the 2009 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 13) "Semi-rigid pitchbreaks including heels" Member end fixity model was used in the analysis and design of this truss. LOAD CASE(S)Standard