Loading...
16B-068 CS 2nd fllor GirderS CalcCS Structure™ 2016.4 [Build 5] kmBeamEngine 4.13.19.1 Materials Database 1548 MontgomeryJesseFlorence - Leve 6-17-16 7:25am 1 of 9 All product names are trademarks of their respective owners Copyright (C) 2016 by Simpson Strong-Tie Company Inc. ALL RIGHTS RESERVED.**Passing is defined as when the member, floor joist, beam or girder, shown on this drawing meets applicable design criteria for Loads, Loading Conditions, and Spans listed on this sheet. The design must be reviewed by a qualified designer or design professional as required for approval. This design assumes product installation according to the manufacturer`s specifications. Doug Hodgins rk Miles Inc. 21 West St. West Hatfield Ma. Member Data Description: CalcG2 Member Type: Girder Application: Floor Comments:Top Lateral Bracing: Continuous Bottom Lateral Bracing: Continuous Standard Load: Moisture Condition: Dry Building Code: IBC/IRC Live Load: 0 PLF Deflection Criteria: L/360 live, L/240 total Dead Load: 0 PLF Deck Connection: Nailed Member Weight: 14.4 PLF Filename: C:\KMW\JOBS\ Other Loads Type (Description) Side Begin End Trib. Width Other Start End Dead Start End Category Replacement Uniform (PLF) Top 0' 0.00" 5' 0.00" 503 0 Snow Replacement Uniform (PLF) Top 0' 0.00" 5' 0.00" 251 323 Live Replacement Uniform (PLF) Top 5' 0.00" 7' 2.75" 503 0 Snow Replacement Uniform (PLF) Top 5' 0.00" 7' 2.75" 251 323 Live Replacement Uniform (PLF) Top 7' 2.75" 10' 7.00" 503 0 Snow Replacement Uniform (PLF) Top 7' 2.75" 10' 7.00" 189 323 Live 1 2 10 7 0 10 7 0 Bearings and Reactions Input Min Gravity Gravity Location Type Material Length Required Reaction Uplift 1 0' 0.000" Wall N/A N/A 1.500" 4411# -- 2 10' 7.000" Wall N/A N/A 1.500" 4314# -- Maximum Load Case Reactions Used for applying point loads (or line loads) to carrying members Live Snow Dead 1 1205# 2468# 1656# 2 1076# 2468# 1656# Design spans 9' 9.750" Product: 1-3/4x9-1/2 VERSA-LAM 2.0 3100 SP 3 ply PASSES DESIGN CHECKS Design assumes continuous lateral bracing along the top chord. Design assumes continuous lateral bracing along the bottom chord. Allowable Stress Design Actual Allowable Capacity Location Loading Positive Moment 10769.'# 25040.'# 43% 5.29' Total Load D+0.75(L+S) Shear 3696.# 10898.# 33% 0.4' Total Load D+0.75(L+S) TL Deflection 0.2485" 0.4906" L/473 5.29' Total Load D+0.75(L+S) LL Deflection 0.1546" 0.3271" L/761 5.29' Total Load 0.75(L+S) Control: TL Deflection DOLs: Live=100% Snow=115% Roof=125% Wind=160% Design assumes a repetitive member use increase in bending stress: 4 % Manufacturer's installation guide MUST be consulted for multi-ply connection details and alternatives CS Structure™ 2016.4 [Build 5] kmBeamEngine 4.13.19.1 Materials Database 1548 MontgomeryJesseFlorence - Leve 6-17-16 7:25am 2 of 9 All product names are trademarks of their respective owners Copyright (C) 2016 by Simpson Strong-Tie Company Inc. ALL RIGHTS RESERVED.**Passing is defined as when the member, floor joist, beam or girder, shown on this drawing meets applicable design criteria for Loads, Loading Conditions, and Spans listed on this sheet. The design must be reviewed by a qualified designer or design professional as required for approval. This design assumes product installation according to the manufacturer`s specifications. Doug Hodgins rk Miles Inc. 21 West St. West Hatfield Ma. Member Data Description: CalcG5 Member Type: Girder Application: Floor Comments:Top Lateral Bracing: Continuous Bottom Lateral Bracing: Continuous Standard Load: Moisture Condition: Dry Building Code: IBC/IRC Live Load: 0 PLF Deflection Criteria: L/360 live, L/240 total Dead Load: 0 PLF Deck Connection: Nailed Member Weight: 5.6 PLF Filename: C:\KMW\JOBS\ Other Loads Type (Description) Side Begin End Trib. Width Other Start End Dead Start End Category Replacement Uniform (PLF) Top 0' 0.00" 3' 3.00" 130 33 Live Replacement Uniform (PLF) Top 0' 0.00" 5' 4.75" 250 63 Live Replacement Uniform (PLF) Top 3' 3.00" 5' 4.75" 130 33 Live 1 2 5 4 12 5 4 12 Bearings and Reactions Input Min Gravity Gravity Location Type Material Length Required Reaction Uplift 1 0' 0.000" Wall N/A N/A 1.500" 1184# -- 2 5' 4.750" Girder N/A N/A N/A 1184# -- Maximum Load Case Reactions Used for applying point loads (or line loads) to carrying members Live Dead 1 936# 248# 2 936# 248# Design spans 4' 11.125" Product: Spruce-Pine-Fir #2 2 x 10 2 ply PASSES DESIGN CHECKS Design assumes continuous lateral bracing along the top chord. Design assumes continuous lateral bracing along the bottom chord. Allowable Stress Design Actual Allowable Capacity Location Loading Positive Moment 1458.'# 3431.'# 42% 2.64' Total Load D+L Shear 814.# 2498.# 32% 0.19' Total Load D+L LL Deflection 0.0182" 0.1642" L/999+ 2.64' Total Load L TL Deflection 0.0230" 0.2464" L/999+ 2.64' Total Load D+L Control: Positive Moment DOLs: Live=100% Snow=115% Roof=125% Wind=160% This member has been designed in accordance with NDS 2005 Minimum bearing length requirements at hangared connections depend on the connection style and are not included in this design. CS Structure™ 2016.4 [Build 5] kmBeamEngine 4.13.19.1 Materials Database 1548 MontgomeryJesseFlorence - Leve 6-17-16 7:25am 3 of 9 All product names are trademarks of their respective owners Copyright (C) 2016 by Simpson Strong-Tie Company Inc. ALL RIGHTS RESERVED.**Passing is defined as when the member, floor joist, beam or girder, shown on this drawing meets applicable design criteria for Loads, Loading Conditions, and Spans listed on this sheet. The design must be reviewed by a qualified designer or design professional as required for approval. This design assumes product installation according to the manufacturer`s specifications. Doug Hodgins rk Miles Inc. 21 West St. West Hatfield Ma. Member Data Description: CalcG6 Member Type: Girder Application: Floor Comments:Top Lateral Bracing: Continuous Bottom Lateral Bracing: Continuous Standard Load: Moisture Condition: Dry Building Code: IBC/IRC Live Load: 0 PLF Deflection Criteria: L/360 live, L/240 total Dead Load: 0 PLF Deck Connection: Nailed Member Weight: 5.6 PLF Filename: C:\KMW\JOBS\ Other Loads Type (Description) Side Begin End Trib. Width Other Start End Dead Start End Category Replacement Uniform (PLF) Top 0' 0.00" 8' 0.50" 27 7 Live Replacement Uniform (PLF) Top 0' 0.00" 8' 0.50" 27 7 Live Point (LBS) Top 0' 4.63" 0 81 Live Point (LBS) Top 0' 4.63" 0 81 Live Point (LBS) Top 0' 4.63" 1 154 Live Point (LBS) Top 0' 4.63" 1 164 Live Point (LBS) Top 0' 4.63" 430 0 Snow Point (LBS) Top 0' 4.63" 473 0 Snow 1 2 8 0 8 8 0 8 Bearings and Reactions Input Min Gravity Gravity Location Type Material Length Required Reaction Uplift 1 0' 0.000" Wall N/A N/A 1.500" 1453# -- 2 8' 0.500" Wall N/A N/A 1.500" 270# -- Maximum Load Case Reactions Used for applying point loads (or line loads) to carrying members Live Snow Dead 1 202# 903# 550# 2 199# 0# 71# Design spans 7' 5.750" Product: Spruce-Pine-Fir #2 2 x 10 2 ply PASSES DESIGN CHECKS NOTE: Pass-thru framing is required at point loads over bearings. Design assumes continuous lateral bracing along the top chord. Design assumes continuous lateral bracing along the bottom chord. Allowable Stress Design Actual Allowable Capacity Location Loading Positive Moment 505.'# 3431.'# 14% 4.12' Total Load D+L Shear 215.# 2498.# 8% 0.4' Total Load D+L LL Deflection 0.0136" 0.2493" L/999+ 4.12' Total Load L TL Deflection 0.0184" 0.3740" L/999+ 4.12' Total Load D+L Control: Positive Moment DOLs: Live=100% Snow=115% Roof=125% Wind=160% This member has been designed in accordance with NDS 2005 Point loads over bearings are NOT included in the Design calculations, but ARE included in the Reaction table CS Structure™ 2016.4 [Build 5] kmBeamEngine 4.13.19.1 Materials Database 1548 MontgomeryJesseFlorence - Leve 6-17-16 7:25am 4 of 9 All product names are trademarks of their respective owners Copyright (C) 2016 by Simpson Strong-Tie Company Inc. ALL RIGHTS RESERVED.**Passing is defined as when the member, floor joist, beam or girder, shown on this drawing meets applicable design criteria for Loads, Loading Conditions, and Spans listed on this sheet. The design must be reviewed by a qualified designer or design professional as required for approval. This design assumes product installation according to the manufacturer`s specifications. Doug Hodgins rk Miles Inc. 21 West St. West Hatfield Ma. Member Data Description: CalcG7 Member Type: Girder Application: Floor Comments:Top Lateral Bracing: Continuous Bottom Lateral Bracing: Continuous Standard Load: Moisture Condition: Dry Building Code: IBC/IRC Live Load: 0 PLF Deflection Criteria: L/360 live, L/240 total Dead Load: 0 PLF Deck Connection: Nailed Member Weight: 5.6 PLF Filename: C:\KMW\JOBS\ Other Loads Type (Description) Side Begin End Trib. Width Other Start End Dead Start End Category Replacement Uniform (PLF) Top 0' 0.00" 8' 3.50" 227 76 Live 1 2 8 3 8 8 3 8 Bearings and Reactions Input Min Gravity Gravity Location Type Material Length Required Reaction Uplift 1 0' 0.000" Wall N/A N/A 1.500" 1191# -- 2 8' 3.500" Wall N/A N/A 1.500" 1191# -- Maximum Load Case Reactions Used for applying point loads (or line loads) to carrying members Live Dead 1 877# 314# 2 877# 314# Design spans 7' 8.750" Product: Spruce-Pine-Fir #2 2 x 10 2 ply PASSES DESIGN CHECKS Design assumes continuous lateral bracing along the top chord. Design assumes continuous lateral bracing along the bottom chord. Allowable Stress Design Actual Allowable Capacity Location Loading Positive Moment 2301.'# 3431.'# 67% 4.04' Total Load D+L Shear 953.# 2498.# 38% 7.52' Total Load D+L LL Deflection 0.0658" 0.2576" L/999+ 4.04' Total Load L TL Deflection 0.0893" 0.3865" L/999+ 4.04' Total Load D+L Control: Positive Moment DOLs: Live=100% Snow=115% Roof=125% Wind=160% This member has been designed in accordance with NDS 2005 CS Structure™ 2016.4 [Build 5] kmBeamEngine 4.13.19.1 Materials Database 1548 MontgomeryJesseFlorence - Leve 6-17-16 7:25am 5 of 9 All product names are trademarks of their respective owners Copyright (C) 2016 by Simpson Strong-Tie Company Inc. ALL RIGHTS RESERVED.**Passing is defined as when the member, floor joist, beam or girder, shown on this drawing meets applicable design criteria for Loads, Loading Conditions, and Spans listed on this sheet. The design must be reviewed by a qualified designer or design professional as required for approval. This design assumes product installation according to the manufacturer`s specifications. Doug Hodgins rk Miles Inc. 21 West St. West Hatfield Ma. Member Data Description: CalcG8 Member Type: Girder Application: Floor Comments:Top Lateral Bracing: Continuous Bottom Lateral Bracing: Continuous Standard Load: Moisture Condition: Dry Building Code: IBC/IRC Live Load: 0 PLF Deflection Criteria: L/360 live, L/240 total Dead Load: 0 PLF Deck Connection: Nailed Member Weight: 5.6 PLF Filename: C:\KMW\JOBS\ Other Loads Type (Description) Side Begin End Trib. Width Other Start End Dead Start End Category Replacement Uniform (PLF) Top 0' 0.00" 2' 3.75" 78 19 Live Replacement Uniform (PLF) Top 0' 0.00" 2' 3.75" 303 76 Live 1 2 2 3 12 2 3 12 Bearings and Reactions Input Min Gravity Gravity Location Type Material Length Required Reaction Uplift 1 0' 0.000" Wall N/A N/A 1.500" 433# -- 2 2' 3.750" Girder N/A N/A N/A 433# -- Maximum Load Case Reactions Used for applying point loads (or line loads) to carrying members Live Dead 1 342# 91# 2 342# 91# Design spans 1' 9.625" Product: Spruce-Pine-Fir #2 2 x 10 2 ply PASSES DESIGN CHECKS Design assumes continuous lateral bracing along the top chord. Design assumes continuous lateral bracing along the bottom chord. Allowable Stress Design Actual Allowable Capacity Location Loading Positive Moment 195.'# 3431.'# 5% 1.12' Total Load D+L Shear 63.# 2498.# 2% 0.23' Total Load D+L LL Deflection 0.0010" 0.0601" L/999+ 1.12' Total Load L TL Deflection 0.0010" 0.0901" L/999+ 1.12' Total Load D+L Control: Positive Moment DOLs: Live=100% Snow=115% Roof=125% Wind=160% This member has been designed in accordance with NDS 2005 Minimum bearing length requirements at hangared connections depend on the connection style and are not included in this design. CS Structure™ 2016.4 [Build 5] kmBeamEngine 4.13.19.1 Materials Database 1548 MontgomeryJesseFlorence - Leve 6-17-16 7:25am 6 of 9 All product names are trademarks of their respective owners Copyright (C) 2016 by Simpson Strong-Tie Company Inc. ALL RIGHTS RESERVED.**Passing is defined as when the member, floor joist, beam or girder, shown on this drawing meets applicable design criteria for Loads, Loading Conditions, and Spans listed on this sheet. The design must be reviewed by a qualified designer or design professional as required for approval. This design assumes product installation according to the manufacturer`s specifications. Doug Hodgins rk Miles Inc. 21 West St. West Hatfield Ma. Member Data Description: CalcG10 Member Type: Girder Application: Floor Comments:Top Lateral Bracing: Continuous Bottom Lateral Bracing: Continuous Standard Load: Moisture Condition: Dry Building Code: IBC/IRC Live Load: 0 PLF Deflection Criteria: L/360 live, L/240 total Dead Load: 0 PLF Deck Connection: Nailed Member Weight: 5.6 PLF Filename: C:\KMW\JOBS\ Other Loads Type (Description) Side Begin End Trib. Width Other Start End Dead Start End Category Replacement Uniform (PLF) Top 0' 0.00" 2' 3.00" 130 33 Live Replacement Uniform (PLF) Top 2' 3.00" 5' 7.63" 130 33 Live 1 2 5 8 8 5 8 8 Bearings and Reactions Input Min Gravity Gravity Location Type Material Length Required Reaction Uplift 1 0' 0.000" Girder N/A N/A N/A 426# -- 2 5' 8.500" Wall N/A N/A 1.500" 426# -- Maximum Load Case Reactions Used for applying point loads (or line loads) to carrying members Live Dead 1 330# 97# 2 330# 97# Design spans 5' 0.875" Product: Spruce-Pine-Fir #2 2 x 10 2 ply PASSES DESIGN CHECKS Design assumes continuous lateral bracing along the top chord. Design assumes continuous lateral bracing along the bottom chord. Allowable Stress Design Actual Allowable Capacity Location Loading Positive Moment 541.'# 3431.'# 15% 2.79' Total Load D+L Shear 297.# 2498.# 11% 0.26' Total Load D+L LL Deflection 0.0070" 0.1691" L/999+ 2.79' Total Load L TL Deflection 0.0090" 0.2536" L/999+ 2.79' Total Load D+L Control: Positive Moment DOLs: Live=100% Snow=115% Roof=125% Wind=160% This member has been designed in accordance with NDS 2005 Minimum bearing length requirements at hangared connections depend on the connection style and are not included in this design. CS Structure™ 2016.4 [Build 5] kmBeamEngine 4.13.19.1 Materials Database 1548 MontgomeryJesseFlorence - Leve 6-17-16 7:25am 7 of 9 All product names are trademarks of their respective owners Copyright (C) 2016 by Simpson Strong-Tie Company Inc. ALL RIGHTS RESERVED.**Passing is defined as when the member, floor joist, beam or girder, shown on this drawing meets applicable design criteria for Loads, Loading Conditions, and Spans listed on this sheet. The design must be reviewed by a qualified designer or design professional as required for approval. This design assumes product installation according to the manufacturer`s specifications. Doug Hodgins rk Miles Inc. 21 West St. West Hatfield Ma. Member Data Description: CalcG13 Member Type: Girder Application: Floor Comments:Top Lateral Bracing: Continuous Bottom Lateral Bracing: Continuous Standard Load: Moisture Condition: Dry Building Code: IBC/IRC Live Load: 0 PLF Deflection Criteria: L/360 live, L/240 total Dead Load: 0 PLF Deck Connection: Nailed Member Weight: 5.6 PLF Filename: C:\KMW\JOBS\ Other Loads Type (Description) Side Begin End Trib. Width Other Start End Dead Start End Category Replacement Uniform (PLF) Top 0' 0.00" 4' 6.00" 27 7 Live Replacement Uniform (PLF) Top 0' 0.00" 8' 4.50" 27 7 Live Replacement Uniform (PLF) Top 4' 6.00" 8' 4.50" 27 7 Live Point (LBS) Top 1' 10.50" 950 273 Live Point (LBS) Top 4' 4.25" 410 118 Live 1 2 8 4 8 8 4 8 Bearings and Reactions Input Min Gravity Gravity Location Type Material Length Required Reaction Uplift 1 0' 0.000" Wall N/A N/A 1.500" 1485# -- 2 8' 4.500" Wall N/A N/A 1.500" 830# -- Maximum Load Case Reactions Used for applying point loads (or line loads) to carrying members Live Dead 1 1143# 342# 2 634# 196# Design spans 7' 9.750" Product: Spruce-Pine-Fir #2 2 x 10 2 ply PASSES DESIGN CHECKS Design assumes continuous lateral bracing along the top chord. Design assumes continuous lateral bracing along the bottom chord. Allowable Stress Design Actual Allowable Capacity Location Loading Positive Moment 2551.'# 3431.'# 74% 3.69' Total Load D+L Shear 1429.# 2498.# 57% 0.19' Total Load D+L LL Deflection 0.0773" 0.2604" L/999+ 4.08' Total Load L TL Deflection 0.1006" 0.3906" L/931 4.08' Total Load D+L Control: Positive Moment DOLs: Live=100% Snow=115% Roof=125% Wind=160% This member has been designed in accordance with NDS 2005 CS Structure™ 2016.4 [Build 5] kmBeamEngine 4.13.19.1 Materials Database 1548 MontgomeryJesseFlorence - Leve 6-17-16 7:25am 8 of 9 All product names are trademarks of their respective owners Copyright (C) 2016 by Simpson Strong-Tie Company Inc. ALL RIGHTS RESERVED.**Passing is defined as when the member, floor joist, beam or girder, shown on this drawing meets applicable design criteria for Loads, Loading Conditions, and Spans listed on this sheet. The design must be reviewed by a qualified designer or design professional as required for approval. This design assumes product installation according to the manufacturer`s specifications. Doug Hodgins rk Miles Inc. 21 West St. West Hatfield Ma. Member Data Description: CalcG14 Member Type: Girder Application: Floor Comments:Top Lateral Bracing: Continuous Bottom Lateral Bracing: Continuous Standard Load: Moisture Condition: Dry Building Code: IBC/IRC Live Load: 0 PLF Deflection Criteria: L/360 live, L/240 total Dead Load: 0 PLF Deck Connection: Nailed Member Weight: 5.6 PLF Filename: C:\KMW\JOBS\ Other Loads Type (Description) Side Begin End Trib. Width Other Start End Dead Start End Category Replacement Uniform (PLF) Top 0' 0.00" 2' 0.00" 1 167 Live Replacement Uniform (PLF) Top 0' 0.00" 2' 0.00" 252 0 Snow Replacement Uniform (PLF) Top 0' 0.00" 8' 0.00" 5 1 Live Replacement Uniform (PLF) Top 0' 0.00" 14' 7.75" -53 -13 Live Replacement Uniform (PLF) Top 0' 0.00" 14' 7.75" 27 7 Live Replacement Uniform (PLF) Top 0' 0.00" 14' 7.75" 40 13 Live Replacement Uniform (PLF) Top 8' 0.00" 11' 10.50" 27 7 Live Replacement Uniform (PLF) Top 11' 10.50" 14' 7.75" 27 7 Live Point (LBS) Top 0' 2.75" 0 125 Live Point (LBS) Top 0' 2.75" 105 30 Snow Point (LBS) Top 0' 2.75" 201 24 Snow Point (LBS) Top 2' 1.50" 7 912 Live Point (LBS) Top 2' 1.50" 2415 0 Snow Point (LBS) Top 8' 1.50" 352 126 Live 1 2 2 0 0 12 7 12 14 7 12 Bearings and Reactions Input Min Gravity Gravity Location Type Material Length Required Reaction Uplift 1 2' 0.000" Wall N/A N/A 1.685" 5086# -- 2 14' 7.750" Wall N/A N/A 1.500" 921# -377# Maximum Load Case Reactions Used for applying point loads (or line loads) to carrying members Live Snow Dead 1 823# 3310# 1776# 2 722# -83# 199# Design spans 2' 0.000" (left cant) 12' 5.125" Product: Spruce-Pine-Fir #2 2 x 10 2 ply PASSES DESIGN CHECKS NOTE: Pass-thru framing is required at point loads over bearings. Design assumes continuous lateral bracing along the top chord. Design assumes continuous lateral bracing along the bottom chord. Review gravity uplift reaction force of 377lbs at bearing 2 and ensure that the structure can resist appropriately. Allowable Stress Design Actual Allowable Capacity Location Loading Positive Moment 3308.'# 3431.'# 96% 8.12' Even Spans D+L Negative Moment 1752.'# 3946.'# 44% 2' Total Load D+S Shear 1034.# 2872.# 35% 1.3' Total Load D+S LL Deflection 0.2488" 0.4142" L/599 8.21' Even Spans L TL Deflection 0.2955" 0.6214" L/504 8.21' Even Spans D+L LL Defl., Lt. -0.1241" 0.2000" 2L/386 0' Even Spans L TL Defl., Lt. -0.1274" 0.2000" 2L/376 0' Even Spans D+L CS Structure™ 2016.4 [Build 5] kmBeamEngine 4.13.19.1 Materials Database 1548 MontgomeryJesseFlorence - Leve 6-17-16 7:25am 9 of 9 All product names are trademarks of their respective owners Copyright (C) 2016 by Simpson Strong-Tie Company Inc. ALL RIGHTS RESERVED.**Passing is defined as when the member, floor joist, beam or girder, shown on this drawing meets applicable design criteria for Loads, Loading Conditions, and Spans listed on this sheet. The design must be reviewed by a qualified designer or design professional as required for approval. This design assumes product installation according to the manufacturer`s specifications. Doug Hodgins rk Miles Inc. 21 West St. West Hatfield Ma. Control: Positive Moment DOLs: Live=100% Snow=115% Roof=125% Wind=160% This member has been designed in accordance with NDS 2005 Point loads over bearings are NOT included in the Design calculations, but ARE included in the Reaction table