32C-046 96 Pleasant St Permit Documents2012-12-28 PRIMARY CONSTRUCTION CONTROL DOCUMENT DESIGN PROFESSIONAL IN RESPONSIBLE CHARGE (submit with permit application) 780 CMR – Massachusetts State Building Code Project Title: _Leashold Improvements to 96 Pleasant Sttreet Date: __December 26, 2012 Project Location: ___96 Pleasant Street, Northampton, MA 01060_________________________ Scope of Project: ____Addition of partitions to create two offices and conference room in first floor tenant space. ____________________________________________________________________________________________ In accordance with 780 CMR, Section 107.0, most specifically 107.3.4 “Design Professional in Responsible Charge” and 107.6 “Construction Control” of the 8th edition of the Massachusetts State Building Code: I, ______Peter E. Lapointe_____________ Mass. Registration Number ____AR 5291 Expiration ___08/13 being a registered professional Engineer/Architect hereby certify that: I am the Design Professional in Responsible Charge and that I am and shall be responsible for reviewing and coordinating submittal documents prepared by others, including phased submittal items, for compatability with the design of the building and for compliance with the requirements of 780 CMR (Massachusetts State Building Code). In addition, I certify that I have prepared or directly supervised the preparation of all design plans, computations and specifications concerning the following: [ x] Entire Project [ ] Architectural [ ] Structural [ ] Mechanical [ ] Fire Protection [ ] Electrical [ ] Other (specify)________________________ for the above named project and that such plans, computations and specifications meet the applicable provisions of 780 CMR (8th edition) the Massachusetts State Building Code, all acceptable engineering practices, and all applicable laws for the proposed project. Furthermore, I understand and AGREE that I (or my designee) shall perform the necessary professional services and be present on the construction site on a regular and periodic basis to determine that the work is proceeding in accordance with the documents approved by the building permit and shall be responsible for the following as specified in 780 CMR Section 107.6.2.2 (8th edition) as applicable: 1.) Review, for conformance to this code and the design concept, shop drawings, samples and other submittals by the contractor in accordance with the requirements of the construction documents. 2.) Perform the duties for registered design professionals in Chapter 17. 3.) Be present at intervals appropriate to the stage of construction to become generally familiar with the progress and quality of the work and to determine if the work is being performed in a manner consistent with the construction documents and this code. I shall submit periodically field/progress reports together with pertinent comments, in a form acceptable to the building official, as well as a “Phased Approval Document” when/as required by the Building Official. Upon completion of the work, I shall submit to the building official a “Final Construction Approval Document” as to the satisfactory completion and readiness of the project for occupancy. Signature and Seal of registered professional: December 24, 2012 Louis Hasbrouck, Building Commissioner City of Northampton Northampton, MA 01060 RE: Tenant Fit-out – 96 Pleasant Street IEBC Code Review Summary The proposed work for the fit out of Commercial Space 1 (see attached Dwg A-2 prepared by Studio One, Inc for Hampden Hampshire Housing Partnership) involves removal of two existing partial height partitions and subdivision of the space into two private offices, a meeting room and common area / reception. The scope of work qualifies as a Level 2 Alteration as defined by the 2009 IEBC. The following is a summary of the applicable code provisions. The existing 3 Story Type 3B (Masonry exterior / wood frame interior) structure encloses 3150 square feet per floor and is fully protected with a sprinkler systems. The current mixed use occupancy includes 28 residential units and two commercial spaces. The first floor includes an accessible entrance and accessible toilet facilities in a common area shared by both commercial tenants and two efficiency apartments with a share bathroom. The scope of work is entirely within the tenant space and does not affect egress components, shaft enclosures, structural elements or the building envelope. The applicable sections of Chapters 6 and 7 of the 2009 IEBC are as follows: Chapter 6 Section 602 – Building Elements and Materials All proposed finishes comply with Chapter 8 of the IBC. Since the building if fully protected with a sprinkler system and none of the work affects corridors or common areas, Class C materials are allowed. Chapter 7 Section 701.3 Compliance The new partitions, doors and finishes fully comply with the 2009 IBC. Sections 704.2 Automatic Sprinkler Systems & 704.4 Fire Alarm & Detection The propose work includes modifications to the existing sprinkler and fire alarm systems to maintain the required coverage due to the proposed alterations. The building owner’s representative is coordinating this work with the contractor performing the alterations to the tenant space. Section 706 – Accessibility The proposed alterations comply with accessibility requirements for clearances, access to doors, door hardware and electrical device locations within the tenant space. Section 708 - Electrical The proposed alterations do not alter existing electrical systems. However, the scope of work includes the addition of lighting controls and power receptacles. Section 709 – Mechanical The proposed alterations do not alter the existing mechanical system. None of the proposed partition locations conflict with the existing layout of diffusers. The existing configuration allows for diffusers to supply each of the proposed enclosed spaces. To the best of my knowledge, the proposed scope of work will be in full code compliance according the requirements of the 2009 IEBC and applicable provisions of the 2009 IBC as adopted by the Commonwealth of Massachusetts. Sincerely yours, Peter Lapointe x2x3x1EQEQ3' - 1"Office02Office03Conference04Reception01Mech07Supplies06Hall053' - 1"101102103REMOVE EXG PARTIALHEIGHT PARTITIONSCENTER PARTITIONON EXG CEILING GRID4' MAIN TEES OFEXG CLG GRIDEXTEND PARTITIONUP TO CEILINGNEW SOUND RATED PARTITIONS: CONTRACTORS OPTION2x4 WD STUDS@ 16"o.c. w/ 1/2 GYP EA SIDE & 3" SOUND BATTS. APPLY RESILIENT CLIPSTO ONE SIDE OF WD STUDS or3 5/8" METAL STUDS @ 24" o.c. w/ 1/2" GYP EA SIDE & 3" SOUND BATTSNOTES:1) INSTALL TOP PLATE OR RUNNER OVER SILL SEALER GASKET & CAULKJOINTS AT FLOOR & CEILING BEFORE APPLYING GYP BD.2) PROVIDE AT LEAST ON STUD CAVITY SEPARATION FOR PROPOSED ELECTRICAL OUTLETSWWHEN SERVING DIFFERENT OFFICES.3) ALL DOORS ARE 3'-0"x6'-8" IN WOOD OR HM FRAMES. PROVIDE SOUND GASKETS FOR SOUNDPROOFING.4) COORDINATE RELOCATION OF SPRINKLER HEADSw/ NEW PARTITION LAYOUT TO MAINTAIN REQUIRED COVERAGE.5) COORDINATE ADDITION OF SMOKE DETECTORS TO MAINTAINREQUIRED COVERAGE.2' - 0"2' - 0"2' - 0"ScaleDateDrawn byArchimetricsDesign Studio28 North Maple StreetFlorence, MA 01062peter lapointe, architectph/fax 413-582-9100Project No. 1/8" = 1'-0"A1Proposed PlanProposed LeaseholdImprovements96 Pleasant Street,Northampton, MA12-26-12pel121201