Loading...
24D-342 Koler Enclosure 60REZGBWeather and Sound Enclosures Industrial Generator Set Accessories Applicable to the following: 25--100REZG 50--150REZGB 80/100REZGD and 80/100RZGD 125/150REZGC and 125/150RZGC Weather Enclosure Standard Features Internal-mounted critical silencer and flexible exhaust connector. Skid-mounted, steel construction with hinged doors. Fade-, scratch-, and corrosion-resistant Kohler Power Armor cream beige automotive-grade textured finish. Lockable, flush-mounted door latches. Vertical air inlet and outlet discharge to redirect air and reduce noise. High wind bracing, 241 kph (150 mph). Available on all models, except 80/100REZGB with steel enclosure and 80/100RZGB with steel enclosure. Sound Enclosure Standard Features Includes all of the weather enclosure features with the addition of acoustic insulation material. Skid-mounted, steel or aluminum construction with hinged doors. Aluminum enclosures are recommended for high humidity and/or high salt/coastal regions. Acoustic insulation that meets UL 94 HF1 flammability classification and repels moisture absorption. Sound attenuated enclosure that uses up to 51 mm (2 in.) of acoustic insulation, acoustic-lined air inlet hoods, and acoustic-lined air discharge hood. 80--150 kW Enclosure 25--60 kW Enclosure G6-108 5/13k Weather and Sound Enclosure Specifications Model Max. Dimensions, mm (in.)Weight, kg (lb.) *Sound Enclosure, Sound Pressure at 7 m (23 ft.), dB(A) at 60 Hz, Full LoadLengthWidthHeight Steel Weather Enclosure Steel Sound Enclosure Aluminum Sound Enclosure 25REZG 2585(101.8)1078 (42.4)1513 (59.6) 855 (1880)860 (1891)768 (1689)68 30REZG 918 (2026)924 (2037)832 (1834)68 40REZG 977 (2149)982 (2160)890 (1958)66 45REZG 1040 (2288)1045 (2299)953 (2096)66 50REZGB 1122 (2475)1127 (2486)1035 (2283)64 60REZGB 1122 (2475)1127 (2486)1035 (2283)65 80REZGD/RZGD 3526(138.8)1153 (45.4)1694 (66.7)1454 (3205)1465 (3228)1403 (3092)72 100REZG 3506(138.0)1156 (45.5)1696 (66.8)1715 (3781)1725 (3803)1539 (3393)74 100REZGD/RZGD 3526(138.8)1153 (45.4)1694 (66.7)1557 (3434)1568 (3457)1506 (3321)72 125REZGB 3506(138.0)1156 (45.5)1696 (66.8)1741 (3837)1751 (3859)1565 (3449)72 125REZGC/RZGC 3526(138.8)1153 (45.4)1724 (67.9)1739 (3834)1758 (3876)1592 (3509)71 150REZGB 3506(138.0)1156 (45.5)1696 (66.8)1856 (4091)1866 (4113)1680 (3703)75 150REZGC/RZGC 3526(138.8)1153 (45.4)1696 (66.8)1877 (4138)1897 (4183)1730 (3813)74 * Weight includes the generator set (wet), enclosure, and silencer. The generator set weight represents using the largest alternator option. Note:Refer to the respective ADV drawings for details. Refer to TIB-114 for complete generator set sound data. ©2009, 2010, 2011, 2012, 2013 by Kohler Co. All rights reserved. DISTRIBUTED BY: G6-108 5/13k Weather and Sound Enclosure ADV-7657- Hinged doors for ease of servicing Lockable, flush- mounted door latches prevent tampering Fixed air flow inlet grille Rodent guards and skid end caps prevent unwanted animal entry Oil drain and radiator drains Fade-, scratch-, and corrosion- resistant powder-baked finish Vertical air discharge through an air outlet grille Enclosed exhaust silencer for improved safety and noise reduction Acoustic insulation meeting UL 94 HF1 flammability classification Alternator access panel (25--60 kW models only) Enclosure ships assembled on generator set skid when ordered installed. Note:25--60 kW shown, other models are similar. Enclosure Features Available in steel (14 gauge) formed panel, solid construction. Preassembled package offering corrosion resistant, dent resilient structure mounting directly to skid. Power Armor automotive-grade finish resulting in advanced corrosion and abrasion protection as well as enhanced edge coverage and color retention. Internal critical exhaust silencer offering maximum component life and operator safety. NOTE:Installinganadditionallengthofexhausttailpipemay increase backpressure levels. Please refer to the generator set spec sheet for the maximum backpressure value. Interchangeable modular panel construction. Allows complete serviceability or replacement without compromising enclosure design. Cooling/combustion air intake with a horizontal air inlet. Sized for maximum cooling airflow. Service access. Multi-personnel doors for easy access to generator set control and servicing of the oil fill and battery. Cooling air discharge. Weather protective design featuring a vertical air discharge outlet grille. Redirects cooling air up and above enclosures to reduce noise ambient. Additional Sound Enclosure Features Available in steel (14 gauge) or aluminum 3.2 mm (0.125 in.) formed panel, solid construction. Attenuated design. Acoustic insulation UL 94 HF1 listed for flame resistance offering up to 25 mm (1 in.) mechanically restrained acoustic insulation. Cooling air discharge. The sound enclosures include acoustic insulation with urethane film. Available Approvals and Listings UL 2200 Listing CSA Approval IBC Seismic Certification NOTE:Somemodelsmayhavelimitedthird-partyapprovals,see your local distributor for details. Kohler Power Systems Asia Pacific Headquarters 7 Jurong Pier Road Singapore 619159 Phone (65) 6264-6422, Fax (65) 6264-6455 KOHLER CO., Kohler, Wisconsin 53044 USA Phone 920-457-4441, Fax 920-459-1646 For the nearest sales and service outlet in the US and Canada, phone 1-800-544-2444 KOHLERPower.com Availability is subject to change without notice. Kohler Co. reserves the righttochangethedesignorspecificationswithoutnoticeandwithoutany obligation or liability whatsoever. Contact your local Kohler generator set distributor for availability.