Loading...
151019_Beede-Houseupu p new flooring to be small hexagon tile similiar to existing new marble style flooring pattern to pick up curve at stair verify pattern with cortina tile Powder Room Entry remove aluminum threshold and fix holes as needed keep existing marble base at Entry (restore) remove and re-install existing toilet protect existing wallpaper in Powder Room during demo. keep existing marble base at Powder Room (restore) new sanitary cast iron linein enclosed chase to basement keep existing marble base at Entry (restore) 36"x48" shower new pedestal sink new toilet remove and re-install toilet remove and reuse existing corner sink, new valves, etc. new flooring and wainscotting at 54" a.f.f. new flooring A1.2 4 12"10" Guest Bath #2 Powder Room shampoo storage recess relocate existing towel bar29 1/2"44 1/2"18" 2x6 plumbing wall new sanitary line to basement below 3 access panel to shower valve removable shelves new wallpaper floor to ceiling 8" Owner: Project Name: Drawing Name: Revisions: Date: Scale: Approvals: Sheet No. Option:NEW HOMES+WORKPLACES+DESIGN+RENOVATIONS+ENERGY RETROFITS+CONSTRUCTION MANAGEMENT48 Bates Street, Northampton, MA 01060413.586.8287 / 413.586.9276 / www.wright-builders.com 3/8" = 1'-0" Floor Plans House Renovations Robert & Fraser Beede 04/03/15 05/12/15 08/27/15 09/14/15 09/28/15 Review Review Review Review Review 83 Round Hill Road Northampton, MA A1.1 - 3/8" = 1'-0"1 First Floor Powder Room & Entry Floor Plan 3/8" = 1'-0"2 Second Floor Guest Bath Plan Drawing List 2015 Interior Sheet # Sheet Name A1.1 Floor Plans House A1.2 Demolition Plan, Electrical Plan and Interior Elevations A2.1 First Floor Plan Storm Windows A2.2 Second Floor Plan Storm Windows A2.3 Third Floor Plan Storm Windows, Schedules and Details 48"24"12"wall niche glass shower door shower control shower head shower base 54"tile wainscotting TBD relocated towel bar tileTBD 8"19 1/2"19 1/2"19 1/2"19 1/2"6"7' - 0"removable storage shelves for access to shower valve panel glass shower door tile TBD 36"x48" shower 1' - 0"10" Guest Bath #2 Powder Room new exhaust fan, duct connected to existing system existing exhaust fan new light fixture at existing opening new gfci e e e e e new light fixture add outlet at wall below remove and reuse existing light at new sink * control wiring by electrition demo switch install high velocity AC port relocated light fixture HVAC install new OC tied to venting new GFCI outlet at existing location existing high velocity AC port existing OC tied to venting vent tied to renew air remove towel bar and save for reuse remove corner sink and save for reuse remove corner sink and save for reuse demo tub and walls demo shelf demo tile floor and wainscotting Owner: Project Name: Drawing Name: Revisions: Date: Scale: Approvals: Sheet No. Option:NEW HOMES+WORKPLACES+DESIGN+RENOVATIONS+ENERGY RETROFITS+CONSTRUCTION MANAGEMENT48 Bates Street, Northampton, MA 01060413.586.8287 / 413.586.9276 / www.wright-builders.com 3/8" = 1'-0" Demolition Plan, Electrical Plan and Interior Elevations Renovations Robert & Fraser Beede 09/28/15Review Review Review Review Review 83 Round Hill Road Northampton, MA A1.2 - 3/8" = 1'-0"3 Int Elevation Guest Bath #2 Shower 3/8" = 1'-0"4 Int Elevation Guest Bath #2 Storage 3/8" = 1'-0"1 Second Floor Electrical Plan 3/8" = 1'-0"2 Guest Bath Demolition Plan UP A1 B1C1 D1E1 F1G1 H1 I1 J1 K1 L1 M1 N1 O1 P1 Dining Room Kitchen Garden Room Porch Porch Living Room Library Foyer VestibulePowder Room Pantry Storage Mud Room Breakfast Pantry Owner: Project Name: Drawing Name: Revisions: Date: Scale: Approvals: Sheet No. Option:NEW HOMES+WORKPLACES+DESIGN+RENOVATIONS+ENERGY RETROFITS+CONSTRUCTION MANAGEMENT48 Bates Street, Northampton, MA 01060413.586.8287 / 413.586.9276 / www.wright-builders.com 1/4" = 1'-0" First Floor Plan Storm Windows Renovations Robert & Fraser Beede 07/06/15 08/27/15 09/28/15 Review Review Review Review Review 83 Round Hill Road Northampton, MA A2.1 - 1/4" = 1'-0"1 First Floor Plan C2 A2B2 D2E2 F2G2 H2 I2 J2 K2 L2 M2 N2 O2 P2 Q2 R2 S2 T2 Master Bedroom Master Bathroom Master Closet StudyGuest Bedroom #1 Guest Bedroom #2 Rotunda Laundry Guest Bath #1 Closet Guest Bath #2 BDRM 1 M. BDRM Owner: Project Name: Drawing Name: Revisions: Date: Scale: Approvals: Sheet No. Option:NEW HOMES+WORKPLACES+DESIGN+RENOVATIONS+ENERGY RETROFITS+CONSTRUCTION MANAGEMENT48 Bates Street, Northampton, MA 01060413.586.8287 / 413.586.9276 / www.wright-builders.com 1/4" = 1'-0" Second Floor Plan Storm Windows Renovations Robert & Fraser Beede 07/06/15 08/27/15 09/28/15 Review Review Review Review Review 83 Round Hill Road Northampton, MA A2.2 - 1/4" = 1'-0"1 Second Floor Plan B3A3 Storage Storage HVAC Closet Chase Third Floor Room Attic Space 3 1/4"5 1/2" add blocking add trim board to attach storm window deep guide line of existing arched wall Jamb Head existing arched wall existing shade pocket (fill void with rigid foam board and spray foam) existing window jamb existing window jamb new storm window new storm window MARK COMMENTS 2 B1 interior storm / missing lower divided lite, modify existing louvered interior shutters to allow install of storms D1 interior storm M1 interior storm, relocate shade E1 interior storm, remove screen in total A2 interior storm / remove screen in total B2 interior storm / remove screen in total C2 interior storm / remove screen in total E2 interior storm / remove screen in total, relocate shade D2 interior storm / remove screen in total, relocate shade F2 interior storm / remove screen in total, relocate shade G2 interior storm / remove screen in total, relocate shade H2 interior storm / remove screen in total, relocate shade J2 interior storm I2 interior storm / remove screen in total, relocate shade K2 interior storm / remove screen in total, relocate shade L2 interior storm / remove screen in total, relocate shade M2 interior storm / remove screen in total, relocate shade O2 interior storm / remove screen in total, relocate shade N2 install storm panel, relocate shade Q2 interior storm / remove screen in total, relocate shade P2 interior storm, relocate shade R2 repair cracked window and repair? or remove screen, relocate shade S2 interior storm / missing locking hardware, relocate shade T2 interior storm / remove screen in total, relocate shade interior storm panel interior storm panelBDRM 1 M. BDRM A3 interior storm (add curved trim to top wall for attachment) B3 interior storm (tempered fixed) (add curved trim to top wall for attachment) N1 interior storm FIRST FLOOR: SECOND FLOOR: THIRD FLOOR: C1 interior storm / missing lower divided lite, modify existing louvered interior shutters to allow install of storms COMMENTS 1 MOL-ST, STACKED ONE LITE W/ HORIZ. MULLION - SEE DRAWING MOL-ST, STACKED ONE LITE W/ HORIZ. MULLION - SEE DRAWING MOL- MAGNETIC ONE LITE MOL- MAGNETIC ONE LITE MOL-ST, STACKED ONE LITE W/ HORIZ. MULLION - SEE DRAWING MOL - MAGNETIC ONE LITE - THIS UNIT TO BE AN ADD ALTERNATE MARK B1 D1 M1 E1 A2 B2 C2 E2 D2 F2 G2 H2 J2 I2 K2 L2 M2 O2 N2 Q2 P2 R2 S2 T2 BDRM 1 M. BDRM A3 B3 N1 FIRST FLOOR: SECOND FLOOR: THIRD FLOOR: C1 MOL- MAGNETIC ONE LITE - TEMPERED GLASS MOL- MAGNETIC ONE LITE - TEMPERED GLASS MOL- MAGNETIC ONE LITE MOL-ST, STACKED ONE LITE W/ HORIZ. MULLION - SEE DRAWING MOL- MAGNETIC ONE LITE MOL- MAGNETIC ONE LITE MOL- MAGNETIC ONE LITE MOL- MAGNETIC ONE LITE MOL- MAGNETIC ONE LITE - LEFT JAMB IS TWISTED MOL- MAGNETIC ONE LITE SAW-2 SLIDE-A-WAY (2) PANEL, EGRESS ISSUES SAW-2 SLIDE-A-WAY (2) PANEL GLASS PANEL ONLY TO BE APPLIED TO WOOD STORM DOOR GLASS PANEL ONLY TO BE APPLIED TO WOOD STORM DOOR MOL- MAGNETIC ONE LITE MOL- MAGNETIC ONE LITE MOL- MAGNETIC ONE LITE MOL- MAGNETIC ONE LITE MOL- MAGNETIC ONE LITE MOL- MAGNETIC ONE LITE MOL- MAGNETIC ONE LITE SAW-2 SLIDE-A-WAY (2) PANEL GLASS PANEL ONLY, RADIUS EYEBROW SHAPE GLASS PANEL ONLY, RADIUS EYEBROW SHAPE - TEMPERED GLASS FIXED FIXED FIXED FIXED FIXED FIXED FIXED FIXED FIXED FIXED FIXED FIXED FIXED FIXED FIXED FIXED FIXED FIXED FIXED FIXED FIXED FIXED FIXED FIXED FIXED FIXED FIXED OPERABLE OPERABLE OPERABLE BEEDE RESIDENCE - INTERIOR STORM WINDOW SCHEDULE TYPE SIZE 45-1/8" X 88" OVERALL 45-1/8" X 88" OVERALL 18-3/4" X 43 1/4" 15-1/8" X 41" 71-1/4" X 88" OVERALL 31-1/4" X 59 7/8" 39-1/2" X 65" 39-1/2" X 65" 15" X 35 1/2" 75-3/4" X 100" OVERALL 15-5/8" X 35 7/8" 39-1/2" X 65" 39-1/2" X 65" 39-1/2" X 65" 39-1/2" X 65" 31-1/4" X 49-1/2" 39-1/2" X 65" 39-1/2" X 65" 25" X 82" 72-1/4" X 65" 29-1/4" X 65" 71-1/2" X 70" 29-1/4" X 65" 71-3/4" X 65" 25" X 82" 31-1/4" X 50" 31-3/8" X 52" 31-3/8" X 49-3/8" 50-1/4" X 19-1/4" 50-1/4" X 19-1/4" O1 no work, existing to remainO1 no work, existing to remainP1 no work, existing to remainA1 no work, existing to remainF1 no work, existing to remainG1 no work, existing to remainH1 no work, existing to remainI1 no work, existing to remainJ1 K1 P1 A1 F1 G1 H1 I1 J1 K1 no work, existing to remain N/AN/A N/A N/AN/A N/A N/AN/A N/A N/AN/A N/A N/AN/A N/A N/AN/A N/A N/AN/A N/A N/AN/A N/A N/AN/A N/A COLOR GLASS WHITE LOW E M1 interior storm, relocate shadeMOL-ST, STACKED ONE LITE W/ HORIZ. MULLION - SEE DRAWINGL1 FIXED SEE DRAWING WHITE WHITE WHITE BROWN LOW EWHITE WHITE WHITE WHITE WHITE WHITE WHITE WHITE WHITE WHITE WHITE WHITE WHITE WHITE WHITE WHITE WHITE WHITE WHITE WHITE WHITE WHITE WHITE WHITE WHITE WHITE LOW E LOW E LOW E LOW E LOW E LOW E LOW E Owner: Project Name: Drawing Name: Revisions: Date: Scale: Approvals: Sheet No. Option:NEW HOMES+WORKPLACES+DESIGN+RENOVATIONS+ENERGY RETROFITS+CONSTRUCTION MANAGEMENT48 Bates Street, Northampton, MA 01060413.586.8287 / 413.586.9276 / www.wright-builders.comAs indicated Third Floor Plan Storm Windows, Schedules and Details Renovations Robert & Fraser Beede 07/06/15 08/27/15 09/28/15 Review Review Review Review Review 83 Round Hill Road Northampton, MA A2.3 - 1/4" = 1'-0"1 Third Floor Plan 1 1/2" = 1'-0"2 Storm Window Blocking Details