Loading...
32C-224 (57)O�'CN/'►N1P�O Grtit r of Nort4antpton DEPARTMENT OF BUILDING INSPECTIONS INSPECTQBruary 27, 2006 212 Main Street • Municipal Building North,unpton, MA 01060 Mr. Charles Wang 79 Hawley Street Northampton, MA 01060 Subject: Fire damaged Electrical Wiring at 79 Hawley Street Dear Mr. Wang, I was called the scene of a fire located at 79 Hawley Street on Feb 2, 2006. The cause of the fire was determined to be electrical, specifically the "knob and tube" wiring to a ceiling light shorted and energized the tin ceiling which the cause and arcing next a steam pipe in contact with tin ceiling and the wall which then ignited wood framing in wall causing the fire. Upon further investigation it was determined that the entire house was served by this "knob and tube" wiring. The house has been tagged as per 780CMR section 121 as unsafe, before the house can be reoccupied it must be made safe. The knob and tube wiring should be replaced as the potential for another fire exists, the existing wiring may have also been compromised by the heat generated by fire and by the 30amp fuses that were installed in panel instead of the rated 15amp the panel called for. Sincerely, Anthony Patillo Building Commissioner City of Northampton