Loading...
48 -029 CS Beam Calc-RidgeviewDev-FloorBeam1-Lot6-RidgeviewEstates-NorthamptonCS Beam 2016.11.3.1 kmBeamEngine 2016.9.0.3 Materials Database 1558 RIDGEVIEW DEVELOPMENT LLC LOT 6 RIDGEVIEW ESTATES NORTHAMPTON, MA 4- 5-17 10:09am 1 of 2 All product names are trademarks of their respective owners Copyright (C) 2016 by Simpson Strong-Tie Company Inc. ALL RIGHTS RESERVED. **Passing is defined as when the member, floor joist, beam or girder, shown on this drawing meets applicable design criteria for Loads, Loading Conditions, and Spans listed on this sheet. The design must be reviewed by a qualified designer or design professional as required for approval. This design assumes product installation according to the manufacturer`s specifications. Bill Lucas Kelly Fradet Lumber 587 North Main St East Longmeadow, Mass 413-785-1558 Member Data Description: BEAM 1 Member Type: Beam Application: Floor Top Lateral Bracing: Continuous Bottom Lateral Bracing: None Standard Load: Moisture Condition: Dry Building Code: IBC/IRC Live Load: 40 PLF Deflection Criteria: L/360 live, L/240 total 1.000" max. LL Dead Load: 15 PLF Deck Connection: Nailed Member Weight: 15.6 PLF Filename: Beam1 Other Loads Type (Description) Side Begin End Trib. Width Other Start End Dead Start End Category Replacement Uniform (PLF) Top 0' 0.00" 54' 11.00" 640 240 Live Point (LBS) Top 11' 7.50" 3928 1524 Live Point (LBS) Top 15' 3.50" 3796 1404 Live Point (LBS) Top 26' 3.50" 1512 821 Live Point (LBS) Top 26' 3.50" 2336 1159 Live Point (LBS) Top 42' 9.31" 6239 3406 Live 1 2 3 4 5 6 7 9 4 8 9 1 0 9 0 0 9 0 0 9 1 0 9 4 8 54 11 0 Bearings and Reactions Input Min Gravity Gravity Location Type Material Length Required Reaction Uplift 1 0' 0.000" Wall Concrete/Masonry 3.500" 1.500" 3394# -29# 2 9' 4.500" Wall Steel 8.000" 4.127" 16249# -- 3 18' 5.500" Wall Steel 8.000" 3.942" 15521# -- 4 27' 5.500" Wall Steel 8.000" 3.620" 14255# -- 5 36' 5.500" Wall Steel 8.000" 3.166" 12466# -- 6 45' 6.500" Wall Steel 8.000" 4.448" 17512# -- 7 54' 11.000" Wall Concrete/Masonry 3.500" 1.500" 3287# -121# Maximum Load Case Reactions Used for applying point loads (or line loads) to carrying members Live Dead 1 2640# 754# 2 11862# 4387# 3 11444# 4077# 4 10602# 3653# 5 9132# 3334# 6 12141# 5371# 7 2624# 663# Design spans 9' 1.875" 9' 1.000" 9' 0.000" 9' 0.000" 9' 1.000" 9' 1.875" Product: 2.0 RigidLam LVL 1-3/4 x 11-7/8 3 ply PASSES DESIGN CHECKS Connect members with 2 rows of 16d common nails at 12.0" oc NOTE: Nails must be applied from both sides Design assumes continuous lateral bracing along the top chord. Design assumes no lateral bracing along the bottom chord. Allowable Stress Design Actual Allowable Capacity Location Loading Positive Moment 15772.'# 33194.'# 47% 42.78' Odd Spans D+L Negative Moment 15445.'# 33194.'# 46% 45.54' Adjacent 5 D+L Negative Unbrcd 11836.'# 13762.'# 86% 45.54' Odd Spans D+L Shear 10839.# 12053.# 89% 44.63' Adjacent 5 D+L CS Beam 2016.11.3.1 kmBeamEngine 2016.9.0.3 Materials Database 1558 RIDGEVIEW DEVELOPMENT LLC LOT 6 RIDGEVIEW ESTATES NORTHAMPTON, MA 4- 5-17 10:09am 2 of 2 All product names are trademarks of their respective owners Copyright (C) 2016 by Simpson Strong-Tie Company Inc. ALL RIGHTS RESERVED. **Passing is defined as when the member, floor joist, beam or girder, shown on this drawing meets applicable design criteria for Loads, Loading Conditions, and Spans listed on this sheet. The design must be reviewed by a qualified designer or design professional as required for approval. This design assumes product installation according to the manufacturer`s specifications. Bill Lucas Kelly Fradet Lumber 587 North Main St East Longmeadow, Mass 413-785-1558 Actual Allowable Capacity Location Loading Max. Reaction 17512.# 31500.# 55% 45.54' Adjacent 5 D+L TL Deflection 0.1174" 0.4542" L/928 41.45' Odd Spans D+L LL Deflection 0.0938" 0.3028" L/999+ 13.92' Even Spans L Control: Shear DOLs: Live=100% Snow=115% Roof=125% Wind=160% Design assumes a repetitive member use increase in bending stress: 4 %