Loading...
23C-110 CS2nd Floor Girder CalcsCS Structure™ 2016.11 [Build 16] kmBeamEngine 2016.9.0.3 Materials Database 1557 BottJeffCaronDeal - Level 8 4-10-17 11:55am 1 of 4 All product names are trademarks of their respective owners Copyright (C) 2016 by Simpson Strong-Tie Company Inc. ALL RIGHTS RESERVED.**Passing is defined as when the member, floor joist, beam or girder, shown on this drawing meets applicable design criteria for Loads, Loading Conditions, and Spans listed on this sheet. The design must be reviewed by a qualified designer or design professional as required for approval. This design assumes product installation according to the manufacturer`s specifications. Doug Hodgins rk Miles Inc. 21 West St. West Hatfield Ma. Member Data Description: CalcG6 Member Type: Girder Application: Roof Comments:Top Lateral Bracing: Continuous Slope: 0.00 / 12 Bottom Lateral Bracing: Continuous Standard Load: Moisture Condition: Dry Building Code: IBC/IRC Live Load: 0 PLF Deflection Criteria: L/360 live, L/240 total Dead Load: 0 PLF Deck Connection: Nailed Member Weight: 24.3 PLF Filename: C:\KMW\JOBS\ Other Loads Type (Description) Side Begin End Trib. Width Other Start End Dead Start End Category Replacement Uniform (PLF) Top 0' 0.00" 5' 0.00" -53 -13 Live Replacement Uniform (PLF) Top 0' 0.00" 5' 0.00" 27 7 Live Replacement Uniform (PLF) Top 0' 0.00" 5' 0.00" 40 13 Live Replacement Uniform (PLF) Top 0' 0.00" 18' 0.00" 9 2 Live Replacement Uniform (PLF) Top 0' 0.00" 18' 0.00" 1 228 Live Replacement Uniform (PLF) Top 0' 0.00" 18' 0.00" 350 0 Snow Replacement Uniform (PLF) Top 5' 0.00" 14' 0.00" 27 7 Live Replacement Uniform (PLF) Top 14' 0.00" 18' 0.00" 27 7 Live 1 2 18 0 0 18 0 0 Bearings and Reactions Input Min Gravity Gravity Location Type Material Length Required Reaction Uplift 1 0' 0.000" Wall SPF Plate (425psi) N/A 2.384" 5319# -54# 2 18' 0.000" Wall SPF Plate (425psi) N/A 2.364" 5274# -- Maximum Load Case Reactions Used for applying point loads (or line loads) to carrying members Live Snow Dead 1 474# 3015# 2304# 2 339# 3015# 2259# Design spans 17' 2.750" Product: 1-3/4x16 VERSA-LAM 2.0 3100 SP 3 ply PASSES DESIGN CHECKS Design assumes continuous lateral bracing along the top chord. Design assumes continuous lateral bracing along the bottom chord. Allowable Stress Design Actual Allowable Capacity Location Loading Positive Moment 22751.'# 67031.'# 33% 9' Total Load D+S Negative Moment 33.'# 58288.'# 0% 2.11' Total Load D+L Shear 4486.# 18354.# 24% 0.4' Total Load D+S TL Deflection 0.3393" 0.8615" L/609 9' Total Load D+S LL Deflection 0.1936" 0.5743" L/999+ 9' Total Load S Control: TL Deflection DOLs: Live=100% Snow=115% Roof=125% Wind=160% Design assumes a repetitive member use increase in bending stress: 4 % Manufacturer's installation guide MUST be consulted for multi-ply connection details and alternatives CS Structure™ 2016.11 [Build 16] kmBeamEngine 2016.9.0.3 Materials Database 1557 BottJeffCaronDeal - Level 8 4-10-17 11:55am 2 of 4 All product names are trademarks of their respective owners Copyright (C) 2016 by Simpson Strong-Tie Company Inc. ALL RIGHTS RESERVED.**Passing is defined as when the member, floor joist, beam or girder, shown on this drawing meets applicable design criteria for Loads, Loading Conditions, and Spans listed on this sheet. The design must be reviewed by a qualified designer or design professional as required for approval. This design assumes product installation according to the manufacturer`s specifications. Doug Hodgins rk Miles Inc. 21 West St. West Hatfield Ma. Member Data Description: CalcG7 Member Type: Girder Application: Floor Comments:Top Lateral Bracing: Continuous Bottom Lateral Bracing: Continuous Standard Load: Moisture Condition: Dry Building Code: IBC/IRC Live Load: 0 PLF Deflection Criteria: L/360 live, L/240 total Dead Load: 0 PLF Deck Connection: Nailed Member Weight: 4.8 PLF Filename: C:\KMW\JOBS\ Other Loads Type (Description) Side Begin End Trib. Width Other Start End Dead Start End Category Replacement Uniform (PLF) Top 0' 0.00" 4' 3.50" 64 14 Live 1 2 4 3 8 4 3 8 Bearings and Reactions Input Min Gravity Gravity Location Type Material Length Required Reaction Uplift 1 0' 0.000" Girder SPF Plate (425psi) N/A N/A 150# -- 2 4' 3.500" Wall SPF Plate (425psi) N/A 1.500" 150# -- Maximum Load Case Reactions Used for applying point loads (or line loads) to carrying members Live Dead 1 116# 34# 2 116# 34# Design spans 3' 7.375" Product: 1-3/4x9-1/2 VERSA-LAM 2.0 3100 SP 1 ply PASSES DESIGN CHECKS Design assumes continuous lateral bracing along the top chord. Design assumes continuous lateral bracing along the bottom chord. Allowable Stress Design Actual Allowable Capacity Location Loading Positive Moment 136.'# 6979.'# 1% 2.1' Total Load D+L Shear 84.# 3159.# 2% 0.3' Total Load D+L TL Deflection 0.0013" 0.1807" L/999+ 2.1' Total Load D+L LL Deflection 0.0010" 0.1205" L/999+ 2.1' Total Load L Control: Shear DOLs: Live=100% Snow=115% Roof=125% Wind=160% Minimum bearing length requirements at hangared connections depend on the connection style and are not included in this design. CS Structure™ 2016.11 [Build 16] kmBeamEngine 2016.9.0.3 Materials Database 1557 BottJeffCaronDeal - Level 8 4-10-17 11:55am 3 of 4 All product names are trademarks of their respective owners Copyright (C) 2016 by Simpson Strong-Tie Company Inc. ALL RIGHTS RESERVED.**Passing is defined as when the member, floor joist, beam or girder, shown on this drawing meets applicable design criteria for Loads, Loading Conditions, and Spans listed on this sheet. The design must be reviewed by a qualified designer or design professional as required for approval. This design assumes product installation according to the manufacturer`s specifications. Doug Hodgins rk Miles Inc. 21 West St. West Hatfield Ma. Member Data Description: CalcG8 Member Type: Girder Application: Floor Comments:Top Lateral Bracing: Continuous Bottom Lateral Bracing: Continuous Standard Load: Moisture Condition: Dry Building Code: IBC/IRC Live Load: 0 PLF Deflection Criteria: L/360 live, L/240 total Dead Load: 0 PLF Deck Connection: Nailed Member Weight: 4.8 PLF Filename: C:\KMW\JOBS\ Other Loads Type (Description) Side Begin End Trib. Width Other Start End Dead Start End Category Replacement Uniform (PLF) Top 0' 0.00" 4' 3.50" -194 -47 Live 1 2 4 3 8 4 3 8 Bearings and Reactions Input Min Gravity Gravity Location Type Material Length Required Reaction Uplift 1 0' 0.000" Wall SPF Plate (425psi) N/A 1.500" 9# -425# 2 4' 3.500" Girder SPF Plate (425psi) N/A N/A 9# -425# Maximum Load Case Reactions Used for applying point loads (or line loads) to carrying members Live Dead 1 -349# -75# 2 -349# -75# Design spans 3' 7.375" Product: 1-3/4x9-1/2 VERSA-LAM 2.0 3100 SP 1 ply PASSES DESIGN CHECKS Design assumes continuous lateral bracing along the top chord. Design assumes continuous lateral bracing along the bottom chord. Review gravity uplift reaction force of 426lbs at bearing 1 and ensure that the structure can resist appropriately. Review gravity uplift reaction force of 426lbs at bearing 2 and ensure that the structure can resist appropriately. Allowable Stress Design Actual Allowable Capacity Location Loading Positive Moment 8.'# 6281.'# 0% 2.19' Total Load D Negative Moment 385.'# 6979.'# 5% 2.19' Total Load D+L Shear 240.# 3159.# 7% 0.4' Total Load D+L TL Deflection -0.0036" 0.1807" L/999+ 2.19' Total Load D+L LL Deflection -0.0030" 0.1205" L/999+ 2.19' Total Load L Control: Shear DOLs: Live=100% Snow=115% Roof=125% Wind=160% Minimum bearing length requirements at hangared connections depend on the connection style and are not included in this design. CS Structure™ 2016.11 [Build 16] kmBeamEngine 2016.9.0.3 Materials Database 1557 BottJeffCaronDeal - Level 8 4-10-17 11:55am 4 of 4 All product names are trademarks of their respective owners Copyright (C) 2016 by Simpson Strong-Tie Company Inc. ALL RIGHTS RESERVED.**Passing is defined as when the member, floor joist, beam or girder, shown on this drawing meets applicable design criteria for Loads, Loading Conditions, and Spans listed on this sheet. The design must be reviewed by a qualified designer or design professional as required for approval. This design assumes product installation according to the manufacturer`s specifications. Doug Hodgins rk Miles Inc. 21 West St. West Hatfield Ma. Member Data Description: CalcG10 Member Type: Girder Application: Floor Comments:Top Lateral Bracing: Continuous Bottom Lateral Bracing: Continuous Standard Load: Moisture Condition: Dry Building Code: IBC/IRC Live Load: 0 PLF Deflection Criteria: L/360 live, L/240 total Dead Load: 0 PLF Deck Connection: Nailed Member Weight: 9.6 PLF Filename: C:\KMW\JOBS\ Other Loads Type (Description) Side Begin End Trib. Width Other Start End Dead Start End Category Replacement Uniform (PLF) Top 0' 0.00" 4' 0.00" 27 7 Live Replacement Uniform (PLF) Top 0' 0.00" 18' 0.00" 27 7 Live Replacement Uniform (PLF) Top 4' 0.00" 13' 0.00" 6 1 Live Replacement Uniform (PLF) Top 13' 0.00" 18' 0.00" -53 -13 Live Replacement Uniform (PLF) Top 13' 0.00" 18' 0.00" 27 7 Live Replacement Uniform (PLF) Top 13' 0.00" 18' 0.00" 40 13 Live Point (LBS) Top 3' 10.25" -388 -65 Live Point (LBS) Top 13' 1.75" 128 56 Live 1 2 18 0 0 18 0 0 Bearings and Reactions Input Min Gravity Gravity Location Type Material Length Required Reaction Uplift 1 0' 0.000" Wall SPF Plate (425psi) N/A 1.500" 614# -319# 2 18' 0.000" Wall SPF Plate (425psi) N/A 1.500" 897# -273# Maximum Load Case Reactions Used for applying point loads (or line loads) to carrying members Live Dead 1 418# 196# 2 626# 271# Design spans 17' 2.750" Product: 1-3/4x9-1/2 VERSA-LAM 2.0 3100 SP 2 ply PASSES DESIGN CHECKS Design assumes continuous lateral bracing along the top chord. Design assumes continuous lateral bracing along the bottom chord. Review gravity uplift reaction force of 319lbs at bearing 1 and ensure that the structure can resist appropriately. Review gravity uplift reaction force of 274lbs at bearing 2 and ensure that the structure can resist appropriately. Allowable Stress Design Actual Allowable Capacity Location Loading Positive Moment 2860.'# 13958.'# 20% 10.72' Total Load D+L Negative Moment 1167.'# 13958.'# 8% 3.85' Total Load D+L Shear 794.# 6317.# 12% 17.39' Total Load D+L TL Deflection 0.3095" 0.8615" L/668 9' Total Load D+L LL Deflection 0.2103" 0.5743" L/982 9' Total Load L Control: LL Deflection DOLs: Live=100% Snow=115% Roof=125% Wind=160% Manufacturer's installation guide MUST be consulted for multi-ply connection details and alternatives