23C-110 CS 1st floor header CalcsCS Structure™ 2016.11 [Build 16] kmBeamEngine 2016.9.0.3 Materials Database 1557 BottJeffCaronDeal - Level 8 4-10-17 11:56am 1 of 2 All product names are trademarks of their respective owners Copyright (C) 2016 by Simpson Strong-Tie Company Inc. ALL RIGHTS RESERVED.**Passing is defined as when the member, floor joist, beam or girder, shown on this drawing meets applicable design criteria for Loads, Loading Conditions, and Spans listed on this sheet. The design must be reviewed by a qualified designer or design professional as required for approval. This design assumes product installation according to the manufacturer`s specifications. Doug Hodgins rk Miles Inc. 21 West St. West Hatfield Ma. Member Data Description: CalcB2 Member Type: Beam Application: Floor Comments:Top Lateral Bracing: Continuous Bottom Lateral Bracing: Continuous Standard Load: Moisture Condition: Dry Building Code: IBC/IRC Live Load: 0 PLF Deflection Criteria: L/360 live, L/240 total Dead Load: 0 PLF Deck Connection: Nailed Member Weight: 9.6 PLF Filename: C:\KMW\JOBS\ Other Loads Type (Description) Side Begin End Trib. Width Other Start End Dead Start End Category Replacement Uniform (PLF) Top 0' 0.00" 9' 3.00" -53 -13 Live Replacement Uniform (PLF) Top 0' 0.00" 9' 3.00" 9 2 Live Replacement Uniform (PLF) Top 0' 0.00" 9' 3.00" 27 7 Live Replacement Uniform (PLF) Top 0' 0.00" 9' 3.00" 40 13 Live Replacement Uniform (PLF) Top 0' 0.00" 9' 3.00" 1 238 Live Replacement Uniform (PLF) Top 0' 0.00" 9' 3.00" 385 0 Snow 1 2 9 3 0 9 3 0 Bearings and Reactions Input Min Gravity Gravity Location Type Material Length Required Reaction Uplift 1 0' 0.000" Wall SPF #3/Stud 2x or 4x End-Grain (650psi) N/A 1.500" 2995# -259# 2 9' 3.000" Wall SPF #3/Stud 2x or 4x End-Grain (650psi) N/A 1.500" 2995# -259# Maximum Load Case Reactions Used for applying point loads (or line loads) to carrying members Live Snow Dead 1 352# 1761# 1235# 2 352# 1761# 1235# Design spans 9' 1.750" Product: 1-3/4x9-1/2 VERSA-LAM 2.0 3100 SP 2 ply PASSES DESIGN CHECKS Design assumes continuous lateral bracing along the top chord. Design assumes continuous lateral bracing along the bottom chord. Review gravity uplift reaction force of 260lbs at bearing 1 and ensure that the structure can resist appropriately. Review gravity uplift reaction force of 260lbs at bearing 2 and ensure that the structure can resist appropriately. Allowable Stress Design Actual Allowable Capacity Location Loading Positive Moment 6849.'# 16051.'# 42% 4.63' Total Load D+S Negative Moment 595.'# 13958.'# 4% 4.63' Total Load D+L Shear 2477.# 7265.# 34% 0.06' Total Load D+S TL Deflection 0.2062" 0.4573" L/532 4.63' Total Load D+S LL Deflection 0.1212" 0.3049" L/905 4.63' Total Load S Control: TL Deflection DOLs: Live=100% Snow=115% Roof=125% Wind=160% Manufacturer's installation guide MUST be consulted for multi-ply connection details and alternatives CS Structure™ 2016.11 [Build 16] kmBeamEngine 2016.9.0.3 Materials Database 1557 BottJeffCaronDeal - Level 8 4-10-17 11:56am 2 of 2 All product names are trademarks of their respective owners Copyright (C) 2016 by Simpson Strong-Tie Company Inc. ALL RIGHTS RESERVED.**Passing is defined as when the member, floor joist, beam or girder, shown on this drawing meets applicable design criteria for Loads, Loading Conditions, and Spans listed on this sheet. The design must be reviewed by a qualified designer or design professional as required for approval. This design assumes product installation according to the manufacturer`s specifications. Doug Hodgins rk Miles Inc. 21 West St. West Hatfield Ma. Member Data Description: CalcB3 Member Type: Beam Application: Floor Comments:Top Lateral Bracing: Continuous Bottom Lateral Bracing: Continuous Standard Load: Moisture Condition: Dry Building Code: IBC/IRC Live Load: 0 PLF Deflection Criteria: L/360 live, L/240 total Dead Load: 0 PLF Deck Connection: Nailed Member Weight: 14.4 PLF Filename: C:\KMW\JOBS\ Other Loads Type (Description) Side Begin End Trib. Width Other Start End Dead Start End Category Replacement Uniform (PLF) Top 0' 0.00" 3' 1.50" 75 0 Snow Replacement Uniform (PLF) Top 0' 0.00" 3' 1.50" 204 161 Live Replacement Uniform (PLF) Top 3' 1.50" 9' 1.50" 75 0 Snow Replacement Uniform (PLF) Top 3' 1.50" 9' 1.50" 204 161 Live Replacement Uniform (PLF) Top 9' 1.50" 12' 3.00" 75 0 Snow Replacement Uniform (PLF) Top 9' 1.50" 12' 3.00" 204 161 Live 1 2 12 3 0 12 3 0 Bearings and Reactions Input Min Gravity Gravity Location Type Material Length Required Reaction Uplift 1 0' 0.000" Wall SPF #3/Stud 2x or 4x End-Grain (650psi) N/A 1.500" 2338# -- 2 12' 3.000" Wall SPF #3/Stud 2x or 4x End-Grain (650psi) N/A 1.500" 2338# -- Maximum Load Case Reactions Used for applying point loads (or line loads) to carrying members Live Snow Dead 1 1239# 456# 1066# 2 1239# 456# 1066# Design spans 12' 1.750" Product: 1-3/4x9-1/2 VERSA-LAM 2.0 3100 SP 3 ply PASSES DESIGN CHECKS Design assumes continuous lateral bracing along the top chord. Design assumes continuous lateral bracing along the bottom chord. Allowable Stress Design Actual Allowable Capacity Location Loading Positive Moment 7000.'# 21774.'# 32% 6.13' Total Load D+L Shear 2005.# 9476.# 21% 11.59' Total Load D+L TL Deflection 0.2512" 0.6073" L/580 6.13' Total Load D+0.75(L+S) LL Deflection 0.1367" 0.4049" L/999+ 6.13' Total Load 0.75(L+S) Control: TL Deflection DOLs: Live=100% Snow=115% Roof=125% Wind=160% Design assumes a repetitive member use increase in bending stress: 4 % Manufacturer's installation guide MUST be consulted for multi-ply connection details and alternatives