23C-110 57 Baker Hill Rd, Northampton - Air LeakageAir Leakage Property 57 Baker Hill Rd Northampton , MA 01062 Weather:Chicopee, MA P15845 57 Baker Hill Rd -final.blg Organization Center for Ecotechnology 413-586-7350 Matt Zarotny Builder Jeff Bott Whole House Infiltration ASHRAE 62.2 - Ventilation Requirements The ASHRAE 62.2 flow rates shown above are the CONTINUOUS mechanical fresh air ventilation which will meet the 'whole-building' requirement under that version of the standard. Both values incorporate any appropriate 'infiltration credit'. Intermittent mechanical ventilation may be used if the flow rate is adjusted accordingly. For example, the runtime can be reduced to 12 hours per day using a doubled flow rate, as long as the system provides ventilation at least once every 3 hours. For more detail, refer to the appropriate standard. REM/Rate - Residential Energy Analysis and Rating Software v15.4 This information does not constitute any warranty of energy cost or savings. © 1985-2017 Noresco, Boulder, Colorado. HERS Confirmed 2017-11-09 Rating No:P15845 Rater ID:2933592 Duct Leakage Ventilation Blower Door Test Heating Cooling Natural ACH 0.09 0.07 ACH @ 50 Pascals 1.32 1.32 CFM @ 25 Pascals 287 287 CFM @ 50 Pascals 451 451 Eff. Leakage Area (sq.in) 24.8 24.8 Specific Leakage Area 0.00008 0.00008 ELA/100 sf shell (sq.in) 0.50 0.50 CFM50/sf shell 0.09 0.09 Leakage to Outside Units CFM @ 25 Pascals 18 CFM25 / CFMfan 0.0035 CFM25 / CFA 0.0225 CFM per Std 152 N/A CFM per Std 152 / CFA N/A CFM @ 50 Pascals 28 Eff. Leakage Area (sq.in) 1.55 Thermal Efficiency N/A Total Duct Leakage Units CFM25/CFA Total Duct Leakage 0.0225 Mechanical Balanced ASHRAE ASHRAE Sensible Recovery Eff. (%) 75.0 62.2-2010 62.2-2013 Total Recovery Eff. (%) 0.0 Rate (cfm) 116 53 80 Hours/Day 12.0 24.0 24.0 Fan Watts 25.0 Cooling Ventilation Natural Ventilation