Invest-Eval Narrative-17105.2AHARONIAN & ASSOCIATES INC. - ARCHITECTS 310 George Washington Highway - Suite 100 - Smithfield, Rhode Island 02917 T 401-232-5010 F 401-232-5080 MA STATE BUILDING CODE INVESTIGATION AND EVALUATION NARRATIVE DUNKIN DONUTS 55 DAMON RD NORTHAMPTON, MA AA# 17105.2 Review Date: JUNE 13, 2018 International Existing Building Code 2015 w/ MA State Building Code 780 CMR 9th Edition Amendments Note: Evaluation was performed using Work Area Compliance Method. Chapter 5 – Classification of Work SECTION 501 GENERAL 501.2 Work Area – The scope of work is to remove a portion of the existing building, all interior components of the remaining building, and provide a shell structure for tenant fit outs, This includes adjustments to the existing plumbing & electrical systems, and add new HVAC systems. The exterior will be refinished in new materials. 506 Change of Occupancy – Proposed Use Group: Mixed use; Business (B) and Mercantile (M); Previous use group was Mercantile (M). Construction Type: 5B - Combustible. SECTION 505 ALTERATION LEVEL 3 This building is classified as an Alteration level 3. This includes Sections 503 and 504 for Alteration Levels 1 and 2. Chapter 7 – Alterations - Level 1 Design complies with all applicable Sections as listed below: SECTION 701 GENERAL SECTION 702 BUILDING ELEMENTS AND MATERIALS SECTION 703 FIRE PROTECTION SECTION 704 MEANS OF EGRESS SECTION 705 ACCESSIBILITY SECTION 707 ENERGY CONSERVATION DUNKIN DONUTS 55 Damon Road, Northampton, MA AA#17105.02 1 of 3 AHARONIAN & ASSOCIATES INC. - ARCHITECTS 310 George Washington Highway - Suite 100 - Smithfield, Rhode Island 02917 T 401-232-5010 F 401-232-5080 Chapter 8 – Alterations - Level 2 Design complies with all applicable Sections as listed below: SECTION 801 GENERAL 801.3 COMPLIANCE - Windows and doors have been added & are not required to met the requirements of IBC & applicable amendments. SECTION 803 BUILDING ELEMENTS AND MATERIALS SECTION 804 FIRE PROTECTION 804.2 – This building is not sprinklered and is not required to be sprinklered. SECTION 805 MEANS OF EGRESS 805.3 – Tenants have not been assigned, so final exit locations and quantity is to be determined. 2 exits per proposed tenant space are shown at this time. SECTION 806 ACCESSIBILITY SECTION 807 STRUCTURAL 807.2 NEW STRUCTURAL ELEMENTS – The existing structural elements have been modified & added in order to comply with IBC new construction. SECTION 808 ELECTRICAL SECTION 809 MECHANICAL 809.1 Reconfigured or Converted Spaces – New mechanical systems shall be provided for each tenant. This work complies with the International Mechanical Code & applicable amendments. SECTION 810 PLUMBING 810.1 Minimum Fixtures – To be determined by tenant. SECTION 811 ENERGY CONSERVATION Chapter 9 – Alterations - Level 3 Design complies with all applicable Sections as listed below: SECTION 901 GENERAL SECTION 904 FIRE PROTECTION SECTION 905 MEANS OF EGRESS SECTION 906 ACCESSIBILITY SECTION 907 STRUCTURAL 907.2 NEW STRUCTURAL ELEMENTS – The existing structural elements have been modified & added in order to comply with IBC new construction. DUNKIN DONUTS 55 Damon Road, Northampton, MA AA#17105.02 2 of 3 AHARONIAN & ASSOCIATES INC. - ARCHITECTS 310 George Washington Highway - Suite 100 - Smithfield, Rhode Island 02917 T 401-232-5010 F 401-232-5080 SECTION 908 ENERGY CONSERVATION Chapter 10 – Change of Occupancy SECTION 1001 GENERAL 1001.1 Scope – The previous occupant was a similar Mercantile (M) occupancy. The proposed occupancy is a mixed use of Business (B) and Mercantile (M). End of Report DUNKIN DONUTS 55 Damon Road, Northampton, MA AA#17105.02 3 of 3