Loading...
38B-216 Garage Beam calcCS Structureâ„¢ 2.06.13[Build 1] kmBeamEngine 4.6.1.0 Materials Database 1492 BranchKristenFortSt - Level 6 12-11-14 2:32pm 1 of 1 All product names are trademarks of their respective owners Copyright (C) 2013 by Simpson Strong-Tie Company Inc. ALL RIGHTS RESERVED.**Passing is defined as when the member, floor joist, beam or girder, shown on this drawing meets applicable design criteria for Loads, Loading Conditions, and Spans listed on this sheet. The design must be reviewed by a qualified designer or design professional as required for approval. This design assumes product installation according to the manufacturer`s specifications. Doug Hodgins rk Miles Inc. 21 West St. West Hatfield Ma. Member Data Description: CalcB7 Member Type: Beam Application: Floor Comments:Top Lateral Bracing: Continuous Bottom Lateral Bracing: (See Below) Standard Load: Moisture Condition: Dry Building Code: IBC/IRC Live Load: 0 PLF Deflection Criteria: L/360 live, L/240 total Dead Load: 0 PLF Deck Connection: Nailed Member Weight: 26.6 PLF Filename: Q:\BranchKri Other Loads Type (Description) Side Begin End Trib. Width Other Start End Dead Start End Category Replacement Uniform (PLF) Top 0' 0.00" 7' 9.50" 220 55 Live Replacement Uniform (PLF) Top 0' 0.00" 22' 8.00" 220 55 Live Replacement Uniform (PLF) Top 7' 9.50" 17' 10.00" 240 60 Live Replacement Uniform (PLF) Top 17' 10.00" 22' 8.00" 240 60 Live Point (LBS) Top 0' 7.13" 0 193 Live Point (LBS) Top 22' 0.88" 0 180 Live 1 2 22 8 0 22 8 0 Bearings and Reactions Input Min Gravity Gravity Location Type Material Length Required Reaction Uplift 1 0' 0.000" Wall N/A N/A 1.652" 6504# -- 2 22' 8.000" Wall N/A N/A 1.679" 6611# -- Maximum Load Case Reactions Used for applying point loads (or line loads) to carrying members Live Dead 1 4820# 1683# 2 4916# 1695# Design spans 21' 5.750" Product: 1-3/4x18 VERSA-LAM 2.0 3100 SP 3 ply PASSES DESIGN CHECKS Design assumes continuous lateral bracing along the top chord. No lateral bracing required along the bottom chord. Allowable Stress Design Actual Allowable Capacity Location Loading Positive Moment 34370.'# 72812.'# 47% 11.33' Total Load D+L Shear 5528.# 17955.# 30% 21' Total Load D+L TL Deflection 0.5587" 1.0740" L/461 11.33' Total Load D+L LL Deflection 0.4270" 0.7160" L/603 11.33' Total Load L Control: LL Deflection DOLs: Live=100% Snow=115% Roof=125% Wind=160% Design assumes a repetitive member use increase in bending stress: 4 % Manufacturer's installation guide MUST be consulted for multi-ply connection details and alternatives